HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Rev. 5B 2-86 Table 2.3.2 DESIGN DATA FOR HI-STORM UMAX ISFSI Type Value (minimum or nominal, as applicable)

Comment

8.

Strain compatible effective shear wave velocity in Space C, V 485 ft/sec minimum This space may be remediated with vertical reinforcement such as pilings to enhance V.

9.

Strain compatible effective shear wave velocity in Space D, V (Figure 2.4.4) 485 ft/sec minimum This space will typically contain native soil.

10.

Design Basis Earthquake Top of the Grade (Ground surface) spectra per Figure 2.4.1 with horizontal ZPA, aH and vertical ZPA, aV scaled as follows:

aH = 1.0g aV = 0.75g and foundation surface pad spectra per Figure 2.4.2 with horizontal ZPA, aH and vertical ZPA, aV of:

aH = 0.93g aV = 0.71g Horizontal and vertical spectra shown in Figures 2.4.1 and 2.4.2 are based on 5%

damping.

Following the Newmark 100-40-40 response combination technique [2.6.7]

endorsed by the Regulatory Guide 1.92

[2.4.7], the resultant ZPA for a 3-D earthquake site is defined as: aR=

a1+0.4a2+0.4a3, where a1, a2 and a3 are the sites ZPAs in three orthogonal directions and a1a2a3.

Hence, the DBE resultant ZPAs at ground surface and foundation surface elevations are 1.3 gs (=1.0x1.0gs + 0.4x0.75 gs) and 1.214 gs (=1.0x0.93gs + 0.4x0.71 gs),

respectively.

11.

Permissible long-term settlement of the SFP 0.2 inch maximum Used as the input value in the strength qualification of the SFP.

12 Density of plain concrete in the Closure Lid (min nom) 150 lb/cubic feet Used in shielding calculations 13 Reference compressive strength of plain concrete in the Closure Lid 4,000 psi Used in analysis of mechanical loadings on the Closure Lid 14 Minimum compressive strength of SES in Space A (see Figure 2.4.4) 1,000 psi Used in tornado missile impact analysis and SSI analysis 15 Density of CEC plenum shield concrete, if applicable 120 lb/ cubic feet Used in shielding calculations

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 5C 5-28 Table 5.3.2 COMPOSITION OF THE MATERIALS IN THE HI-STORM FW SYSTEM Component Density (g/cm3)

Elements Mass Fraction (%)

Metamic 2.642 B-10 4.388 B-11 20.436 Al 68.275 C

6.901 Metamic-HT

[PROPRIETARY INFORMATION WITHHELD IN ACCORDANCE WITH 10 CFR 2.390]

Carbon steel 7.82 Fe 99.0 C

1.0 SS304 7.94 Cr 19.0 Mn 2.0 Fe 69.5 Ni 9.5 Concrete 2.4 (150 lb/ft3)

[note 1 deleted]

O 53.2 Si 33.7 Ca 4.4 Al 3.4 Na 2.9 Fe 1.4 H

1.0 Soil 1.7 H

0.962 O

54.361 Al 12.859 Si 31.818

[Note 1 deleted]

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 5C 5-45 Table 5.4.6 DOSE RATES ADJACENT TO THE HI-STORM UMAX MODULE WITH VERSION B LID FOR NORMAL CONDITIONS MPC-37 DESIGN BASIS ZIRCALOY CLAD FUEL Location Value Side of the VVM lid Adjacent to the Inlet Vent 22 mremr/hr Table 5.4.7 DESIGN BASIS DOSE RATE LIMITS Location Value Side of HI-TRAC 3500 mrem/hr Standard Lid (On the side of the closure lid approximately midheight) 66 mremr/hr Version B Lid (On the side of the closure lid approximately midheight and adjacent to the inlet vent) 22 mremr/hr