ML20097F318
| ML20097F318 | |
| Person / Time | |
|---|---|
| Site: | Brunswick |
| Issue date: | 06/09/1992 |
| From: | Mccarthy D CAROLINA POWER & LIGHT CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NLS-92-140, NUDOCS 9206150245 | |
| Download: ML20097F318 (115) | |
Text
)
O
(,h h )
$ %;}Id.03 Cetolina Ponet & Light Company iJun 001992 SERIAL:
NLS - 92 140 United States Nuclear Regulatory Conaission ATTDITION:
Document Control Desk Vashington, DC 20555 f>RUNSVICK STEAM ELECTRIC Pl/diT, UNIT NOS. 1 AND 2 DOCKET NOS. 50 325 AND 50-324/ LICENSE N05. D.I'R 71 AND DPR-62 D4ERGENCY RESPONSE DATA SYSTD4 - SURVEY RESPONSE Centlemen:
The purpose of this let ter is to provide Carolina Poar & Light Company's cominunications description and survey questionne.re information regarding the Emergency Response Data System for the Brunswick Steam Electric Plant, Units 1 and 2 (BSEP162).
This survey, the Plant Attribute Library (PAL), is provided in Enclosuro 1.
Also provided is the Data Point Library (DPL) for BSEP162.
Enclosures 2 and 3, respectively, provide this information.
Should you have any questions regarding this matter, please contact Mr. Fred Emerson et (919) 546 7573.
4 Yours very truly,
'/t r.
n i v<- c
. $)L ci v' David C. McCarthy Manager Nuclear Licensing Section DBB/jbw Enclosures cc:
Mr. S. D. Ebneter M r. R. Io Mr. R. L. Prevatte A
4 i
a s
44 l
CO N M i E1",ID',F76sOUJM T RMTn FIY" f7TJ N OIT rd n1 r.. w. m e s e r.,. e oe..
u%
9206150245 920609 "J
'm
( *"
PDR ADOCK 05000324 F
-_m ENCLOSURE 1 PLANT ATTRIBUTE LIBRARY BRUNSWICK STEAM ELECTRIC PLANT SITE l
l l
(1634ctu)
' - - ' ~
uee in e--w-r w e-e*w--'N w
ww-arw-
-re's e-we's'weev=='am*m--emer--m u vewb-rM"wwPWwnM-
---t--ett++W'ym+
= - -
r
-*ww
-4="-
l'a ge !
I.
Contacts Note: Please proside name, title, mailing address, and phone number.
A. Survey Coordinator (i.e., contact for later clarification of questionnaire answers):
Mr. Eugene O. Eagle, Senior Engineer (919) 457 2287 Carolina Power & light 11runswick Steam 10cctric Plant, NiiD - Traitor #107 P.O.1kix 10129 Soutliport, NC 2M61-0129 B.
Computer Hardware Specialist (s):
Mr. Eugene 0, llagle, Senior IIngineer Carolina Power & IJght Ilrunswick Steam Electric Plant, NED - Trailor #107 P.O. Ikix Int 29 Southgxirt, NC 2M614129 C.
Systems Software Specialist (s):
Mr. Eugene O. Eagle, Senior Engineer Carolina Power & IJght Ilrunswick Steam Electric Plant, NIID - Traitor #107 P.O. Ikix 1G129 Southport, NC 2M61-0129 I
D.
Application-level Software Specialist (s):
Mr. Eugene O. Eagle, Senior Engineer Carolina Power & IJght 1kunswick Steam Electric Plant, NiiD - Trailor #107 P.O. Ik)x 10129 Southport, NC 2M614129 E.
Telephone Systems Specialist (s):
Mr, Wayne Pearce, Manager of Site Informatina Scavices, 919-157 3386 Carolina Power & Lic,ht Brunswick Steam Electric Plant P.O. Iku: 10429 -
Southport, NC 2M61-0129 112 N U R EG.1394, llev.1 i
Page 2 II.
ERDS Communications Description l
Ilruruwick Steam Electric Plant takes no exception to the Section 11 of NUllEG-1394, llev.1.
I i
1 l
t B6 NUREG-1394, Rev.1
Page 3
- III, Selection Of Data Feedera A.
Ilow many data feeders are there (six maximum)?
At Brunswick Steam Electric Plant, there is one data feeder per unit, for a total of two.
B.
Identify the selected data feeders and provide the following for each:
(1) a short description of the categories of data points it sill provide (e.g., met, rad, or plant data points, by unit) and (2) the rationnie for selecting it if another system can also provide its categories of data points.
(1)
Each data feeders will provide all data points for the corresponding unit, including met, rad, and p; ant data. In addition, each data feeder will provide the reactor building and turbine buikling rad points associated with gaseous eft!uent release for the other unit.
(2)
%c single data feeder per unit approach was selected because the existing hardware configuration channelled all the information needed by the Safety Parameter Display System through the selected computer system.
' C.
Which data feeder is the site time determining feeder? This should be the feeder which is providing the majority of the data points.
Each data feeder is the time determining feeder for its associated unit. Although the times between the individual units' data feeders are expected to be reasonably ckwe, there is no true time synchronization between them.
B.7 NUREG-1394, Rev.1
-Page 4 III.
Data Feeders Information BSEP 1
Note: A new Section IV must be filled out for each feeder system selected
- General Questions 1.
Identification of Data Feeder What is the name in local parlance given to this data feeder (e.g., Emergency a.
Response Information System)? Please give both the acronym and the word
- forming it.
ERFIS - Emergency Response Facility Information System b.
Is this the site time determining feeder?
Yes, for Brunswick Steam Electric Plant, Unit 1.
c.
How often will this feeder transmit an update set to the ERDS (in seconds)?
- Once every 15 seconds.
2.
Ilardware/ Software Environment a.
Identify the manufacturer and model number of the data feeder hardware.
Digital Equipment Corporation, VAX8600 w/rerminal Servers b.
Identify the operating system.
VAX VMS 4.7
- c. -
What trethod of timekeeping in implemented on this feeder system (Daylight Savings, Standard, Greenwich)?
Daylight Savings d.
In what time zone is this feeder located?
Eastern L
B8 NUREG-1394, Rev.1 r
l
Page 5 USEP1 3.
EData Communication Details Can this data feeder provide asynchronous serial data communication (RS-232 C)
~
a.
with full-modem control?
Yes b.
Will this feeder transmit in ASCII or EBCDIC?
ASCII c.
Can this feeder transmit at a serial baud of 2400 bps? If not, at what haud rate can it transmit?
Yes d.
Does the operating system support XON/XOFF flow control?
- Yes 1.
Are any problems foreseen with the NRC using XON/XOFF ta control the transmission of data?
No c.
If it is feasible to reconfigure a serial port for the ERDS linkup (i.e., change the baud rate, parity, etc.), please explain why?
Not applicable.
f.
Do any ports currently exist for the ERDS linkup?
Yes 1.
If not,is it possible to add additional ports?
Not applicable.
B-9 NUREG-1394, Rev.1
}
Page 6 BSEP1 2.
If yes, will the port be used solely by the ERDS or shared with other non.cmergency-time users? Give details.
Nonnally, the port assigned for use by the ERDS will be reserved for the sole ua of the ERDS. %is would not exclude the occasional use of the port as required to test and ensure satisfactory operation.
4.
Data Feeder Physical Environment and Management a.
Where is the data feeder located in terms of the TSC, EOF, and control room?
%e data feeder is kicated in the EOF portion of the EOF /ISC building at Unmswick Steam Electric Plant. %c data fou! cts for lxith units are housed in the same nxim. %c EOF /ISC building is onsite but outside the protected area.
b.
Is the data feeder prote.ed from loss of supply of electricity?
Yes c.
Is there a human operator for this data feeder?
Yes 1.
-If so, how many hours a day is the feeder attended?
%c Shift Technical Advisor is available 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to activate the ERDS.
~
Unless called in, personnel who conduct maintenance or testing activities
- would normally only be available during normal business hours.
B.10 NUREG 1394, Rev.1
Page 7 III.
Data Feeders Information BSEP 2 Note: A new Section IV must be filled out for each feeder system selected.
Genend Ouestions 1.
Identification of Data Feeder What is the name in local parlance given to this data feeder (e.g., Emergency a.
Response Information System)? Please give both the acronym and the word forming it.
ERFIS - Emergency Response Facility Information System b.
Is this the site time determining feeder?
Yes, for Brunswick Steam Electric Plant, Unit 2.
How often will this feeder transmit an update set to the ERDS (in seconds)?
- c.
Once every 15 seconds.
2.
Ilardware/ Software Emironment Identify the manufacturer and model number of the data feeder hardware.
a.
Digital Equipment Corporation, VAX8600 w/I'erminal Servers b.
Identify the operating system.
VAX VMS 4.7 What method of timekeeping in implemented on this feeder system (Daylight c.
Savings, Standard, Greenwich)?
Daylight Savings d.
In what time zone is this feeder located?
Eastern I
B-8 NUREG-1394, Rev. I
Page 8 USEP 2 3.
. Data Communication Details a.
Can this data feeder provide asynchronous serial data communication (RS-232-C) with full-modem control?
t Yes b.
Will this feeder transmit in ASCl! or EBCDIC?
ASCII c.
Can this feeder transmit at a serial baud of 2400 bps? If not, at what baud rate can it transmit?
Yes d.
Does the operating system support XON/XOFF flow control?
Yes 1.
Are any problems foreseen with the NRC using XON/XOFF to control the transmission of data?
No l
If it is' feasible to reconfigure a serial port for the ERDS linkup (i.e., change the e.
baud rate, parity, etc.), please explain why?
Not applicable.
f.
Do any ports currently exist for the ERDS linkup?
Yes 1.
If not, is it possible to add additional ports?
L Not' applicable.
l l
l B-9 NUREG-1394, Rev.1 l
L
l 1
Page 9 USEP 2 2.
If yes, will the port be used solely by the ERDS or shared with other non cmergency-time users? Give details.
Normally, the port assigned for use by the ERDS will be re.wrved for the sole use of *he ERDS. His would not exclude the occasional use of the port as required to test and ensure satisfactory operation.
4.'
Data Feeder Physical Envirunment and Management Where is the data feeder located in terms of the TSC, EOF, and control room?
a.
ne data feeder is kx ated in the EOF portion of the EOF /ISC building at Brunswick Steam Electric Plant ne data feeders for lx)th units are housed in the same room. De EOF /ISC building is onsite but outside the protected area.
b.
Is the data feeder protected from loss of supply of cicctricity?
Yes Is there a human operator for this data feeder?
c.
i Yes 1.
If so, how many hours a day is the feeder attended?
De Stdft Technical Advisor is available 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to activate the ERDS.
Unless called in, personnel who conduct maintenance or testing actisities would normally only be available during normal business hours.
B-10 NUREG-1394, Rev.1
ENCLOSURE 2 DATA POINT LIBRARY BRUNSWICK STEAM ELECTRIC PLANT i
j UNIT 1 (1634GLU)
Page 10 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Ur.it:
BKl Data Feeder:
N/A NRC ERDS Parameter:
NI POWER RNC Point ID; C5100010 l'lant Spec Point Desc.:
RX VALIDATED POWER READOUT Ceneric/Cond Dese,:
Nuclear Instruments, Power Range Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
Linear (APRM reading); 1% = 24.36 MWt Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.125E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC-or SENS:
P Number of Sensors:
6 (APRM inputs)
How Processed:
APRM Weighted average
- Cain Adj Factor Sensor Locations:
APRM signals to Control Room meters Alarm / Trip Set Points:
LOW = 0,300E+1 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A, need.2 2 inputs for COOD Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Cain Adj Factor is processed from various heat-balance related sensors. APRM input points default to actual values when inputs exceed signal rsnges.
NUREC-1394, Rev. 1 C4
Page 11 DATA POINT LIBRARY REFERENCE FILE
-Date:
05/15/92 Reactor Unit:
BK1-Data Feeder:
N/A NRC ERDS Parameter:
NI INTER RNG Point ID:
N/A Plant Spec Point Desc..
N/A Generic /Cond Dese,:
Nuclear Instruments, Intermediate Range Analog / Digital:
A Engr Units / Dig States:
AMP Engr' Units Conversion:
N/A Minimum Instr Range:
N/A Maximum Instr Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
N/A Number of Sensors:
N/A How Processed:
N/A Sensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on-Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
This parameter is not monitored at BKl.
l' NUREG-1394, Rev. 1 C-4 l
_.. _. ~
Page 12 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
ERI Data Feeder:
N/A NRC ERDS Parameter:
NI SOURC RNC Point ID:
C51NA021 Plant Spec. Point Dese.:
SRM A COUNT RATE Ceneric/Cond Dese.:
Nuclear Instruments Source Range Analog / Digital:
A Engr Units / Dig States:
C/SEC Engr Units Conversion.
Ant 11og-10 Minimum Instr Range:
0,100E+00 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENb:
S Number of Sensors:
1 How Processed:
N/A
' Sensor Locations:
SRM is at core location 12-33.
Alarm / Trip Set Points:
LOW = 0.500E+01: HICH = 0.500E+06 NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply l,
Turn on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N/A l
Level Reference Leg:
N/A Unique System Desc.:
Signal is the same that drives the "A" SRM meter in the control room.
SRM point def aults to appropriate range limit value t
when input exceeds signal range.
i NUREC-1394, Rev. 1 C-4
Page 13 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor. Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
NI SOURC RNG Point ID:
C51NA022 Plant Spec Point Desc.:
SRM B COUNT RATE a
Ccneric/Cond Desc.;
Nuclear Instruments, Source Range
- Analog / Digital:
A Engr Units / Dig States:
C/SEC Engr Units Conversion:
I.ntilog 10 Minimum Instr Range:
0.100E+00 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A
- PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
SRM is at core location 28 41.
Alarm / Trip Set Points:
LOW = 0.500E+01; HICH = 0.500E+06 NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply
-Tuin on Power Level:
N/A Instrument Failure Mode:
LOW /HICl!
Temperature Compensation For DP Transmitters:
N/A
-Level Reference Leg:
N/A
-Unique System Desc.:
Signal is the same that drives the "B"
SRM meter in the control room.
SRM point defaults to appropriate range limit value when input exceeds signal range.
NUREC 1394, Rev. 1 C-4 naus a
i iu in i i
l Page 14 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
NI SOURC RNG Poir.t ID:
C51NA023 Plant Spec Point Desc.
SRM C COUNT RATE Ceneric/Cond Desc.*
Nuclear Instruments, Source Range Analog / Digital:
A Engr Units / Dig States:
C/SEC Engr Units Conversion:
Antilog-10 Minimum Instr Range:
0.100E+00 Maximum Instr Range:
0.100E+07 Zero Point P.eference.
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
I How Processed:
N/A Sensor Locations:
SRM is at core location 36-25.
Alarm / Trip Set Points:
LOW = 0.500E+01; HICH = 0.500E+06 NI Detector Power Supply Cut-off Power Level:
N/A
=
NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.
Signal is the same that drives the "C"
SRM metc - in the control room.
SRM point defaults to appropriate range limit value when input exceeds signal range.
NUREC-1394, Rev. 1 C-4
Page 15 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BKl Data Feeder:
N/A NRC ERDS Parameter:
NI SOURC RNC Point ID:
C51NA024 Plant Spec Point Desc..
SRM D COUNT RATE Ceneric/Cond Desc.:
Nuclear Instruments, Source Range Analog / Digital:
A Engr Units / Dig States:
C/SEC Engr Units Conversion:
Antilog-10 Minimum Instr Range:
0.100E+00 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
SRM is at core location 20-17.
Alarm / Trip Set Points:
LOW = 0.500E+01; HICH = 0.500E+06 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Signal is the same that drives the "D"
SRM meter in the control room.
SRM point defaults to appropriate range limit value when input exceeds signal range.
NUREC-1394, Rev. 1 C-4
i Page.16 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 j
Reactor Unit:
BRI
-Data Feeder:
N/A NRC ERDS Parameter:
REAC VES LEV Point ID:
B2100010 Plant Spec Point Desc.:
RPV VALIDATED WTR LEVEL READOUT Ceneric/Cond-Desc.:
Reactot Vessel Water 19 vel Analog / Digital:
A Engr Units / Dig States:
IN Engr Units Conversion:
Linear (RPV vater level)
Minimum Instr Range:
0.150E+03 Maximum Instr Range:
0,550E+03 Zero Point
Reference:
TAF Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
15 (RPV level inputs) llow Processed:
Accuracy weighted average Sensor Locations:
Level transmitters on RB 20' & 50' el.
Alarm / Trip Set Points:
LOW = 0,163E+ 03 ; 111011 = 0,208E+03 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A, need 2 2 inputs for C00D Temperature Compensation For DP Transmitters:
Y Level Reference Leg:
WET Unique System Dese.:
The processing compensates for Drywell and Reactor Building temperatures, and Reactor pressure, calibration conditions, and Recirculation pump operating status.
RPV water level input points default to actual values when inputs exceed signal ranges.
i NUREC 1394, Rev. 1 C-4 i
Page 17 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
MAIN FD FLOW Point ID:
C51C8003 Plant Spec Point Desc..
TOTAL FEEDWATER FLOW SMOOTHED Generic /Cond Desc.:
Feedwater Flow into the Reactor System Analog / Digital:
A Engr Units / Dig States:
MLB/HR Engr Units Conversion:
Square root (feedwater. low)
Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.120E+02 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
2 (feedwater flow inputs)
How Processed:
Sum smoothed, density compensated flows Sensor Locations:
FE @ #5 FW heater outlet; FT @ TB 20'el Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A, need 2 2 inputs for C00D Temperature Compensation For DP Transmitters:
Y Level Reference Leg:
N/A Unique System Dese.:
Processing includes smoothing with a 30 second time constant and compensation for feedwater temperature and reactor pressure Feed flow input points default to actual values when inputs exceed signal ranges.
NUREG-1394, Rev. 1 C-4
-Page 18 DATA POINT LIBRARY REFERENCE FILE Date:
05/1$/92 Reactor Unit:
BKl Data Feeder:
N/A NRC ERDS Parameter:
RCIC FLOW Point ID:
E51FA004 Plant Spec Point Desc.:
RCIC PUMP DISCHARCE FLOW Ceneric/Cond Dese.:
Reactor Core Isolation Cooling Flow Analog / Digital:
A Engr Units / Dig States:
CPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.500E403 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before test flow line; FT @ RB 17'el Alarm / Trip Set Points:
HICH = 0,410E+03 NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
RCIC flow input point defaults to actual value shen input exceeds signal range.
Temperature correction curve for flow from the DP transmitter does not exist.
l NUREG-1394, Rev. 1 C-4 i
L Page 19 DATA POINT LIBRARY REFERENCE FILE
~-te:
05/15/92
--Reactor Unit:
'BK1 Data Feeder:
N/A NRC ERDS Parameter:
RCS PRESS Point ID:
B21C0210 Plant Spec Point Desc.:
RPV YALIDATED PRESSURE READOUT Ceneric/Cond Desc.:
Reactor Coolant System Pressure Analog / Digital:
A Engr Units / Dig States:
PSIC Engr Units Conversion:
Linear (RPV pressure)
Minimuu Instr Range:
0.000E+00 Maximum Instr Range:
0.150E+04 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
11 (RPV pressure inputs)
How Processed:
Accuracy veighted average Sensor Locations:
Pressure transmitters on RB 20' & 50'el Alarm / Trip Set Points:
HICH = 0.1045E+04 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument-Failure Mode:
N/A, need 2 2 inputs for C00D Temperature Compensation For DP Transmitters:
N/A Level. Reference Leg:
N/A Unique System Desc.:
RPV pressure input points default to actual values when inputs exceed signal ranges.
NUREG 1394, Rev. 1 C-4
Page 20 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
EKI Data Feeder:
N/A NRC ERDS Parameter:
HPCI FLOW Point ID:
E41FA001 Plant Spec Point Desc.:
HPCI PUMP DISCHARGE FLOW Generic /Cond Desc.:
liigh Pressure Coolant Injection F*4cw Analog / Digital:
A n
Engr Units / Dig States:
KGPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.500E+01 Zero Po& ;.t
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before test flow linc: FT G RB 17'el Alarm / Trip Set Points:
HIGH = 0.430E+01 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /HIGH Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A
-Unique System Dese.:
if 1
HPCI flow input point defaults to actual value when input exceeds signal range.
Temperature correction curve for flow f rom the DP transmitter does not exist.
I j
--NUREG-139(, Rev. 1 C4
e Page 21 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BKl Data Feeder:
N/A NRC ERDS Parameter:
LPCI FLOW m
Point ID:
ElllA005 Plant Spec Point Desc.;
RHK LOOP A SYSTEM FLOW l
Generic /Cond Dese,-
Low Prassure Coolant Injection Flow Analog / Digital:
A Engr Units / Dig Etates:
KGPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.300E+02 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before Torus or DW Spray: FT @ RB 17'el Alarm / Trip Set Points:
N/A
-NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW /HIGH Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Ur.ique System Desc :
RHR A flow input point defaults to the actual value when input exceeds the signal range.
Temperature correction curve for flow from the DP transmitter does not exist.
NUREG 1394, Rev. 1 C-4 i
i
Page 22 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
EK1 Data Feeder:
N/A NRC ERDS Parameter:
LPCI FLOW Point ID:
EllFA006 Plant Spec Point Desc.:
RHR LOOP B SYSTEM FLOW Generic /Cond Dese.:
Low Pressure Coolant Injection Flow Analog / Digital:
A Engr Units / Dig States:
ECPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.300E+02 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before Torus or DW Spray; FT @ RB 17'el Alarm /Yrip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
RHR B flow input point defaults to the actual value when input exceeds the signal range.
Temperature correction curve for flow from the DP transmitter does not exist.
NUREG-1394, Rev. 1 C-4
+
Page 23.
DATA POINT LIBRARY REFERENCE FILE j.
Date:.
05/15/92.
Reactor Unit:
BKl Data Feeder:
N/A NRC ERDS Parameter:
CR SPRAY FL Point ID:
E21FA001 Plant Spec Point Desc.:
CORE SPR/V TUMP A FLOW Ceneric/Cond Dese,:
Core Spray Cooling i atem Flow f
Analog / Digital:
_A Engr Units / Dig Sta' :s:
KCPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.700E+01 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S
. Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before test flow line; FT @ RB 17'el Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI_ Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW /H4CH Temperature Compensation For DP Transmitters:
N l
Level Reference Leg:
N/A Unique System Desc.:
Core Spray A flow input point defaults to the actual value when input exceeds the signal range.
Temperature correction curve for flow from the DP transmitter does not exist.
l NUREG-1394, Rev. 1 C4 l
l Page 24 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92-Reactor Unit:
BKl Data. Feeder:
N/A
.NRC ERDS Parameter:
CR SPRAY FL Point ID:
E21FA002 Plant Spec Point Desc.:
CORE SPRAY PUMP B FLOW Generic /Cond Dese.:
Core Spray Cooling System Flow Analog / Digital:
A Engr Units / Dig States:
KCPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.700E+01 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before test flow line; FT @ RB 17'el Alarm / Trip Set Points:
N/A NI-Detector Power Supply Cut off Power Level:
N/A-NI Detector Power Supply Turn on Power Level:
N/A-Instrument Failure Mode:
LOW /HICH e
Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
Core Spray B flow input point dafaults to the actual value when input exceeds the signal range.
Temperature correction curve for flow f rom the DP transmitter does not exist.
NUREC-1394, Rev. 1 C-4
Page 25 DATA POINT - LIBRARY REFERENCE FILE D. ate:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS. Parameter:
N/A Plant Spec Point Desc.:
N/A Ceneric/Cond Dese.:
Drywell vloor Drain Sump Level Analog / Digital:
N/A Engr Units / Dig States:
IN Engr Units Conversion:
N/A Minimum Instr Range:
N/A Haximum Instr Range:
N/A
- Zero Point
Reference:
N/A'
-Reference Point Notes:
N/A PROC or SENS:
N/A Number of Sensors:
N/A How Processed:
N/A Sensor Locations:
N/A I
Alarm / Trip-Set Points:
K/A NI Detector Power Supply Cut-off Power Level:
N/A NI Detector-Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique _ System Desc..
This parameter is not monitored at BKl.
I-NUREC-1394, Rev. 1 C-4
Page 26 DATA POINT - LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
EFF GAS RAD Point ID:
Dl?R0303 Plant Spec Point Desc.:
RB ROOF NOB CAS RAD CACAT-12643 Ceneric/Cond Desc.:
Radioactivity of Released Casses Analog / Digital:
A Engr Units / Dig States:
CPM Engr Units. Conversion:
kntilog-10 Minimum Instr Range:
0.100E+02 Maximum Instr Range:
0.100E407 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number cA Sensors:
1 How Processed:
Alarm checked Sensor Locations:
Line to U1 RB vent; sensor.@ RB 166'c1 Alarm / Trip Set Points:
111011 = Variable limits per ODCM NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrumrat Failure Mode:
N/A Temperature Compensation For.DP Transmitters:
N/A
' Level Reference Leg:
N/A Unique System Desc.:
RB rad input point defaults to appropriate range limit values, when input exeeds signal range.
EFF_CAS_ RAD (RBl)
=
D17R0303
- VA_FA004
- CONT 1000 ODCM ensures compliance with T.S.*
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 10CFR50 36a and App I.,
40CFR190.
NUREG 1394, Rev. 1 C-4
~
Page 27 DATA POINT LIBRARY REFERENCE FILE
-Date:
05/15/92 Reactor Unit:
BKl Data Feeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
VA_FA004 Plant Spec Point Desc.:
U l RX BLDG ROOF VENT FLOW Ceneric/Cond Desc.:
Reactor Building Vent Flow Rate Anal'og/ Digital:
A Engr Units / Dig States:
KSCFM Engr Units Conversion:
Linear Minimum Instr Range:-
0.000E+00 t
Maximum Instr Range:
0,200E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A i
Sensor Locations:
-Alarm / Trip Set.oints:
LOW = 0.iO0E402 NI Detector Power Supply Cut +off Power Level:
N/A NI Detector Pcwer Supply Turn-on-Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.
RB flow input point defaults to appropriate range limit values, when input exceds-signal range.
EFF_CAS_ RAD (RB1)
=
i D17R0303
- VA_FA004
- CONT 1000 ji l
l l
NUREG-1394, Rev. 1 0
(
Page 28 DATA POINT - LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BR1 Data Feeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
CONT 1000 Plant Spec Point Dese.:
Generic /Cond Desc..
RB Vent Rad Monitor Efficiency Analog / Digital:
A Engr Units / Dig States:
(see below)
Engr Units Conversion:
N/A
' Minimum Instr Range:
N/A Maximum Instr Range:
N/A Zero Point
Reference:
N/A Reference ~ Point Notes:
N/A
-PROC or SENS:
P Number of Rensors:
0 Hev Processed:
Equated to constant Sensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A
-Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A
-Unique System Desc.:
Engineering units are (pCI/SEC)/(CFM* CPM).
Radiation monitor efficiency changes with L
L calibration.
EFF_CAS_ RAD (RBl) =
D17R0303
- VA_FA004
- CONT 1000 l
l NUREC-1394, Rev. 1 C-4
~.
Page 29-DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BKl Data-Feeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
D17R0?06 Plant Spec Point _Desc.:
U2 RB ROOF NOB CAS RAD Ceneric/Cond Desc.:
Radioactivity of Released Casses Analog / Digital:
A Engr Units / Dig-States:
CPM Engr Units Conversion:
Antilog-10 Minimum Instr Range:
0.100E+02 Maximum Instr Range:
0.100E+07 Zero Point-
Reference:
N/A Reference Point Notes:
N/A 9
PROC or:SENS:
Number of Sensors:
1 How Processed:
Alarm checked Sensor. Locations:
Line to U2 RB vent; sensor @ RB 166'el Alarm / Trip Set Points:
HICH = Variable limits per ODCM N1 Patector Power. Supply Cat off Power Level:
N/A NI Detector Power Supply Turn on' Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique-System Desc.:
RB rad input point def aults to appropriate range limit values, when input exeeds signal range.
EFF_CAS_ RAD (RB2) =
D17R0306
- VA_FA104
- CONT 101c ODCM ensures compliance witt 3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 100FR50 36a and App I.,
40CFR190.
NUREC 1394, Rev. 1 C-4
Page 30 DATA POINT LIllil AltY REFEREllCE FILE Date:
05/15/92 Reactor Unit:
BRI Data Feeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
VA_FA104 Plant Spec Point Desc.:
U 2 RX ELDC ROOP VENT / LOW Genetic /Cond Desc.:
Reac'or Building Vent Flow Rate Analog / Digital:
A Engr Units / Dig States:
RSCFM Engr Units Conversion:
Linear Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.200E402 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
Alarm / Trip Set Points:
LOW = 0.200E402 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A 9
level Reference Leg:
N/A Unique System Desc.:
RB flow input point defaults to e
appropriate range limit values, when input exceds signal range.
EFF_CAS_ RAD (RB2)
=
Dl?RO'06
- VA_FA104
- CONT 10 '
3 NUREC 1394, Rev. 1 C-4
=
Page 31 DATA POIllT L1111t Ally llEFEllEllCE FILE Date:
05/15/92 Reactor Unit:
BKl Data Teeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
CONT 1010 Plant Spec Point Dese.:
U 2 RB YENT MON EFFIC FAC Ceneric/Cond Dese.:
RB Vent had Monitor Efficiency Analog / Digital:
A Engr Unitt-Dig States:
(see below)
Engr Units Conversion:
N/A Minimum Instr Range:
N/A 11aximum Instr Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
0 llow Processed:
Equated to constant Sensor Locations:
N/A Alarm / Trip Set Points:
N/A 1
NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Engineering units are (pCI/SEC)/(CFM* CPM).
Radiation monitor efficiency changes with cali' ration.
EFF_CAS_ RAD (RB2)
=
u D17R0306
- VA_FA104
- CONT 1010 NUREC-1394, Rev. 1 C4
Page 32 DATA POINT LIl3HARY REFERENCE FILE i
Date:
05/15/92 Reactor Unit:
BRI Data Peeder:
N/A NRC ERDS Parameter:
EFF GAS RAD Point ID:
Dl?R0307 Plant Spec Point Dese.:
TURB BLDG VENT RAD STAT D12 MS80 Generic /Cond Desc.:
Radioactivity of Released Casses Analog / Digital:
A
. Engr Units / Dig States:
pCI/S Engr Units Conversion:
Antilog 10 Hinimum Instr Range:
0.100E*01 Haximum Instr Range:
0.100E+13 Zero Point
Reference:
N/A Reference Point Notes:
N/A l' ROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
Line to Ul TB vent; sensor @ CTB 29'el Alarm / Trip Set Points:
111011 = Variable limits per ODCH NI Detector Power Supply Cut off Pover Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A
vel Reference Leg:
N/A
. Unique System 9 esc.;
ODCM ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20. 10CFR50 36a and App I.,
40CFR190.
1 i
Ul TB vent radiation release input point defaults to the appropriate range limit value when input exceeds signal range.
-NUREG 1394, Rev. 1 C4
_ - ~
l' age 33 DATA POINT LIBRARY REFEllENCE FILE Date:
05/15/92 Reactor Unit:
BK!
Data Peeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
D17R0309 Plant Spec Point Dese.:
U2 TB VENT RAD STAT 2D12 MS80 Generic /Cond Dese.:
Radioactivity of Released Casses Analog / Digital:
A v.ngr Units / Dig States:
pCI/5 Engr Units Conversion:
Antilot 10 Minimum Instr Range:
0.100E+01 Maximum Instr Range:
0.100E+13 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
Line to U2 TB vent; sensor G CTB 29'el l
Alarm / Trip Set Points:
IIIGli = Variable limits per ODCM r
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power LJvel:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
ODCH ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
L 10CFR20, 10CFR50 36a and App I., 40CFR190, U2 TB vent radiation release input point defaults to the appropriate range limit value when input exceeds signal range.
NUREC 1394, Rev. 1 C4
Page 34 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor init:
BKl Data Feede.:
N/A NRC ERDS Paraceter:
EFF GAS RnD Point ID:
D17R0311 Plant bpec Point Desc.:
STACK ETFLUENT RAD STAT D12*MS80 Ceneric/Cond Desc.:
Radioactivity of Released Casces i
Analog / Digital:
A Engr Units / Dig States:
pCI/S Engr Units Conversion:
Antilog-10 Minimum Instr Range:
0.100E+02 Maximum Instr Range:
0.100E+14 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 Now Processed:
Alarm ch2cked Sensor Locations:
Line to main stack; sensor @ DCB 6'el Alarm / Trip Set Points:
111C11 = Variable limits per ODCM NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Dese.:
ODCM also ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
100FR20, 10CFR50 36a and App I.,
40CFR190.
l Stack radiation release input point defaults to the appropriate range limit value when input exceeds signal range.
NUREC 1394, Rev.'l C4 t
l
~..,...
..n,
, -,~
n.-
=
Page 35 l
DATA POINT LIDRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 l
Data Feeder:
N/A NRC EPDS Parameter:
EFF LIQ RAD Point ID:
D17R0401 1
Plant Spec Point Desc.:
SERVICE WTR RAD STAT D12RE N008 Ceneric/Cond Desc.:
Radioactivity of Released Liquids Analog / Digital.:
A Engr Units / Dig States:
CPS Engr Units Conversion:
Antilog 10 Minimum Instr Ran6e:
0.100E+00 Maximum Instr _ Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1
!!ow Processed:
Alarm checked Sensor Locations:
RB Alarm / Trip Set Points:
111011 = Variable limits per ODCM NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation
'For DP Transmitters:
N/A Level Refercnce Leg:
N/A Unique-System-Desc.:
ODCM also ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20,10CFR50 36a and App I., 40CFR190.
Sevice water rad input point defaults to appropriate limit range value when input exceeds _ signal range.
Up to 5 pumps may be in service w/ flow =about 8000 gpm/ pump.
Sensor efficiency is 0.406E 06 pCI/ml/ cps.
.NUREC 1394 Rev. 1 C4 l-l
,. ~
. -. ~.
Page 36 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
CND A/E RAD Point ID:
D17E0210 Plant Spec Pcint Dese.:
SJAE RAD STAT Generic /Cond Dese.:
Condenser Air Ejector Radioactivity Analog / Digital:
A Engr Units / Dig States:
N/A Engr Units Conversion:
Tristate Minimum Instr Range:
0 Maximum Instr Range:
2 Zero Point Refere:ce:
COMPLX Reference Point Notes:
0 = No rma l : 1 = Caution; 2 = Alarm PROC or SEN5:
P Number of Sensors:
0 llow Processed:
Alarm status checked Sensor Locations:
N/A Alarm /Tsip Set Points:
N/A
-NI Detector Power Supply Cut off Power Level:
N/A.
NI Detector Power Supply
' Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Value rep.esents the more limiting status of the two SJAE rad alarm points:
D17R0201 and D17R0202.
SJAE radiation input points default to the appropriate range limit values when inputs exceed signal ranges.
NUREG 1394, Rev. 1 C-4
[
Page 37 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder N/A NRC ERDS Parameter:
CND A/E RAD Point ID:
D17R0201 Plant Spec Point Desc.:
SJAE RAD MON A STAT D12RE N004A Generic /Cond Desc.:
Condenser Air Ejector Radioactivity Analog / Digital:
A Engr Units / Dig States:
HR/IIR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E401 Haximum Instr Range:
0.100E+07
'I Zero Point
Reference:
N/A
= Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
TB Alarm / Trip Set Points:
111011 = Variabic per ODCM NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A l
Unique System Dese.:
ODCM also ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 10CFR50 36a and App I.
40CFR190.
SJAE-radiation input point defaults to I.
the appropriate range limit value when input exceed signal range.
Sensor-efficiency, units of (pCI/sec)/(mR/hr cfm) changes weekly with gas mix.
Limits are based conservatively on the worst gas mix.
NUREG 1394; Rev. 1 C-4
Page 38 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BKl Data Feeder:
N/A NRC ERDS Parameter:
CND A/L RAD Point ID:
D17R0202 Plant Spec Point Dese.:
SJAE RAD MON B STAT D12RE N004B Cencric/Cond Desc.:
Condenser Air Ejector Radioactivity Analog / Digital:
A Engr Units / Dig States:
MR/IIR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E401 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P 1
Number of Sensors:
I flow Processed:
Alarn checked Sensor Locations:
TB Alarm / Trip Set Points:
IIICl! = Variable per ODCM NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg N/A Unique System Desc.:
ODCM also ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 10CFR50 36a and App I., 40CFR190.
SJAE radiation input point defaults to the appropriate range limit value when input exceed signal range.
Sensor l
efficiency, units of (pCI/sec)/(mR/hr cfm) changes weekly with gas mix.
Limits are based conservatively on the worst gas mix.
L NUREC 1394, Rev. 1 C-4 l'
1
Page 39 DATA POINT LIDilAllY llEFEllENCE FILE Datet 05/15/92 Reactor Unit:
ItK1 Data Peeder:
N/A 3
NRC EkDS Parameter:
DW RAD Point ID:
D17E0611 i
Plant Spec Point Dese.:
PRI CNTMT RAD STAT Ceneric/Cond Dese.:
Radiation Level in the Drywell Analog / Digital:
A Engr Units / Dig States:
N/A Engr Units Conversion:
Tristate Hinimum Instr Range:
0 Maximwn Instr Range:
2 Zero Point
Reference:
COMPLX Reference Point Notes:
0 = Normal: 1 = Caution: 2 = Al a rm PROC or SENS:
P Number of Sensors:
0 Ilow Processed:
Alarm status checked Sensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A l
NI Detector Power Supply l
Turn on Power Level:
N/A Instrument Pailure Mode:
N/A Temperature Compensation t
Fo. DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Value represents the more limiting status of the four drywell rad alarm points:
D17R0610, Dl?R0611, D17R0612 and D17R0613.
DW radiation input points default to the appropriate range limit values when inputs exceed signal ranges, NUREG 1394, Rev. 1 C4
l i
Page 40 DATA POINT LIDHARY REFERENCE FILE i
Date:
05/15/92
?
Reactor Unit:
BRI Data reeder:
N/A NRC ERDS Parameter:
DW RAD Point ID:
Dl?R0610 Plant Spec Point Dese.:
PC !!! RNC 30' RAD STAT D22RM4195 Generic /Cond Dese,:
Radiation Level in the Drywell i
Analog /Digitalt A
Engr Units / Dig States:
R/liR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E+01 Maximum Instr Range:
0.100E+08 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or $1NS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
In Drywell @ RB 30' el.
Alarm / Trip Set Points:
11I011 = 0.100E+03 NI Detector Power Supply Cut off Power Level:
N/A Turn on Power Level:pply NI Detector' Power Su N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference 1.eg:
N/A Unique System Dese,:
Drywell radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
l NUREG-1394, Rev. 1 0-4 i
J
Page 41 DATA POINT LIllitMlY llEFEllENCE FILE Date:
05/15/92 Reactor Unit IIKI F
Data Feeder:
N/A NRC ERDS Parameter:
DW RAD Point ID:
D17R0611 Plant Spec Point Desc.:
PC ll! RNC 57' RAD STAT D22kM4196 j
Generic /Cond Dese.:
Radiation Level in the Drywell Analog /Digitalt A
Engr Units / Dig States:
R/llR Engr Units Conversion:
Antilog+10 Minimum Instr Range:
0.100E+01 Maximum Instr Range:
0.100E+08 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P
-Number of Sensors:
1 How Processed:
Alarm checked Sensor Locations:
In Drywell @ RB 57' el.
-Alarm / Trip Set Points:
IIICl! = 0.100E+03 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn +on Power Level N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Dese.:
Drywell radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
NUREC+1394, Rev. 1 C+4
Page 42 DATA POINT LIBRARY REFERENCE FILE Date:
05/!5/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
DW RAD Point ID:
D17R0612 Plant Spec Point Dese.:
PC 111 RNG 23' RAD STAT D22RM4197 Generic /Cond Dese.:
Radiation Level in the Drywell Analog / Digital:
A Engr Units / Dig States:
R/IIR Engr Units Conversion:
Antilog 10 Minimwn Instr Range:
0.100E+01 Maximum Instr Range:
0.100E+08 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
In Drywell @ RB 23' el.
Alarm / Trip Set Points:
IIICll = 0.100E+03 NI Detector Power Supply Cut off Power Level N/A l
NI Detector Power Supply Turn on Power Level:
N/A l
Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Drywell radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
l NUREG 1394, Rev. 1 C4
lage 43 DATA PDINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BKl Data Feeder:
N/A NRC.ERDS Parameter:
DW RAD Point ID:
D17R0613 Plant Spec Point Desc.:
PC llI RNC 57' RAD STAT D22RM4198 Ceneric/Cond Dese.:
Radiation Level in the Drywell Analog / Digital:
A Engr Units / Dig States:
R/IIR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E+01 Maximum Instr Range:
0.100E+08 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Senso.es:
1 Ilow Processed:
Alarm checked Sensor Locations:
In Drywell @ RB 57' el.
Alarm / Trip Set Points:
!!IGli = 0.100E+ 03 NI Detector Power Supply Cut off Power Level:
N/A NI Petector Power Supply Turn on Povar Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters
- N/A Level Reference Leg:
N/A Unique System Desc.:
Drywell radiation input point defaults to the appropriate _ range limit value when input exceed signal ranges.
.NUREG 1394, Rev. 1 C4
f Page 44 DATA POINT LIBRAllY llEFEllENCE FILE Date:
05/15/92 Reactor Unit:
BR1 Data Feeder:
N/A NRC ERDS Parameter:
MN STEAM RAD Point ID:
D17E0110 Plant Spec Point Desc.:
MSL RADIATION STAT Ceneric/Cond Dese.:
Radiation Level of the Main Steam Line l
Analog / Digital:
A EnEr Units / Dig States:
N/A Engr Units Conversiont Tristate Minimum Instr Range:
0 Maximum Instr Range:
2
{
Zero Point
Reference:
COMPLX i
Reference Point Notes:
0 = Normal; 1 = Caution: 2 = Alare PROC or SENS:
P Number of Sensors:
O llow Processed:
Alarm status checked Sensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System-Dese.:
Value represents the more limiting status of the 4 main steam line rad alarm points:
D17R0101, D17R0102. D17R0103 and Dl?R0104.
MSL radiation input points default to the appropriate range-limit values wh'n inputs exceed signal ranges.
NUREG 1394, Rev. 1 C-4
..~
Page 45 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
MN STEAM RAD Point ID:
D17R0101 Plant Spec Point Desc.:
MSL A RAD STATUS D12RE+N006A Generic /Cond Desc.:
Radiation Level of the Main Steam Line Analog / Digital:
A Engi' Units / Dig States:
MR/IIR Eng. Units Conversion:
Antilog 10 Minimur Instr Range:
0.100E+0!
Haximum Instr Range:
0.100E+07 i
Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC.or SENS:
P Number of Sensors:
1
!!ow Processed:
Alarm checked Sensor Locations:
Near outboard isolat. valve @ RB 50'el Alarm / Trip Set Points:
IIICl! = Variable per Tech. Specs.
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure r. ode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
The Technical Specifications limits are based on background radiation which can change f requer.tly due to !!ydrogen Injection.
Main Steam Line radiation input point defaults to the appropriate range limit value when input exceed signal ranges, NUREC 1394, Rev. 1 C-4
_. ~.. _ _ _. _ _ _
Page 46 j
DATA POINT LIHilARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
MN STEAM RAD Point ID:
D17R0102 Plant Spec Point Desc.:
MSL B RAD STATUS D12RE N006B Ceneric/Cond Dese.:
Radiation Level of the Main Steam Line Analog / Digital:
A Engr Units / Dig States:
MR/IIR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E+01 Maximum Instr Range:
0.100E407 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
Near outboard isolat. valve @ RB $0'el Alarm / Trip Set Points:
!!ICll = Variable per Tech. Specs.
+
ENI Detector Power Supply
-Cut off Power Level:
N/A NI Detector Power Supply l
Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
The Technical. Specifications limits are i
based on background radiation which can change f requently due to 11ydrogen Injection. Main Steam Line radiation input point defaults to the appropriate l
range limit value when input exceed signal ranges.
NUREC 1394, Rev. 1 C-4
Page 47 DATA POINT LIUllAllY REFEllENCE FILE Date:
05/15/92 Reactor Unit:
DKl Data Feeder N/A NRC ERDS Parameter:
MN STEAM RAD Point ID:
D17R0103 Plant Spec Point Desc.:
MSL C RAD STATUS D12RE+N0060 l
Generic /Cond Dese.:
Radiation Level of the Main Steam Line Analog / Digital:
A I
Engr Units / Dig States:
MR/llR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E+01 Maximum Instr Range:
0.100E407 Zero Point
Reference:
N/ A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 Ilow Processed:
Alarm checked Sensor Locationst Near outboard isolat. valve G EB 50'el Alarm / Trip Set Points:
IIICl! = Variable per Tech. Specs.
NI Detector Power Supply Cut off Power Level:
N/A NI Dctector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP-Transmitters:
N/A Level Reference Leg:
N/A Unique System-Dese.:
The Technical Specifications limits are based on background radiation.which can change frequently due to liydrogen Injtetion. Main Steam Line radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
NUREC 1394, Rev. 1 C4
-.. ~.. _
Page 48 DATA POINT LIllllAllY llEFEllENCE FILE Date:
05/15/92 Reactor ifnit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
R9 STEAM RAD Point ID:
D17R0104 Plant Spec Point Desc.:
MSL D RAD STATUS D12RE N006D
-Generic /Cond Dese.:
Radiation Level of the Main Steam Line Analog / Digital:
A En r Units / Dig States:
MR/11R o
Engr Units. Conversion:
Antilog*10 Minimum Instr Range:
0.100E+01 Haximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
Near outboe i isolat. valve G nB 50'el
~
Alarm / Trip Set Points:
111011 = Variable per Tech. Specs.
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A i
Level Reference Leg:
N/A Unique System Dese.:
The Technical Specifications limits are based on background radiation which can change f requently due to !!ydrogen f
Injection.
Main Steam Line radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
l NUREC 1394. Rev. 1 C4 1
I Page 49 i
DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
DW PRESS L
Point ID:
D2300010 Plant Spec Point Desc.;
DRYWELL VALIDATED PRESS + READOUT Ceneric/Cond Dese.:
Drywell Pressure Analog / Digital:
A Engr Units / Dig States:
PSIC Engr Units Conversion:
Linear (Drywell pressure)
Minimum Instr Range:
0.500E401 i
Maximum Instr Range:
0.245L403 Zero Point
Reference:
N/A Reference Point-Notes:
N/A PROC or SENS:
P Number of Sensors:
4 (Drywell pressure inputs) llow Processed:
Accuracy weighted average Sensor Locations:
Alarm / Trip Set Points:
111011 = 0.18054 01 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A, need 2 2 inputs for GOOD Temperature Compensation For DP Transmitters:
N/A Level Reference 1.eg:
N/A Unique System Desc.:
Drywell pressure input points default to actual values when inputs exceed signal ranges.
NUREG 1394, Rev. 1 C4
Page 50 DATA POINT LIBil AltY ILEFEllENCE FILE Date:
05/15/92 Reactor Unit:
EKI Data Feeder:
N/A NRC ERDS Parameter:
DW TEMP Point ID:
D23C0310 Plant Spec Point Dese.:
DRYWELL TEMPERATURE READOUT Ceneric/Cond Dese.:
Drywell Temperature Analog / Digital:
A Engr Units / Dig States:
DECF Engr Units Conversion:
Telemetry from Supp. Pool Temp. Hon. Sys Minimum Instr Range:
0.320E402 A
Maxlmum Instr Range:
0.350D 03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
13 (Drywell temperature inputs) llow Processed:
Regional weighted or arithmetic average Sensor Locations:
TE's in drywell between 10' and 92' el Alarm / Trip Set Points:
HICll = 0,300E+03 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Arithmetic average is used as a backup for the regionally-va!ghted average, w
NUREG 1394, Rev. 1 C4
___m.__
____.___-._.m_____________m.___
_a
PaSe 51 DATA POINT LIl3 rally llEFERENCE FILE i
Date:
05/15/92 Reactor Unit:
El;l Data Feeder:
N/A NRC ERDS Parameter:
SP TEMP
=
Point ID:
D23C0210 Piant Spec Point Dese.:
POOL TEMP TREND /BAR/ READOUT Generic /Cond Desc.:
Sup'pressionPoolTemperature Analog /Digitel:
A Engr Units / Dig States:
DECF Engr Units Conversion:
Telemetry from Supp. Pool Temp. Hon. Sys Minimum Instr Range:
0.320E+02 i
Maximum Instr Range:
0,212E+03 Zero Point
Reference:
-N/A Reference Point Notes:
N/A PROC or SENS:
P
-Number of Sensors:
24 (Suppression pool temperature inputa) llow' Processed:
Regional weighted or arithmetic average Sensor Locations:
TE's in torus @ varlocs azimuths Alarm / Trip Set Points:
111C11 = 0.950E+02 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation l
For DP Transmitters:
N/A-Level Reference Leg:
N/A b,iquefyttemDese,:
Arithmetic average is backup for regional-weighted average; maximum pool temp counts 2
as one reElon, NUPfe A094, Rev. 1 C-4 l-l~
d
Page $2 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK!
Data Feeder:
N/A NRC'Er70 Parameter:
Tv LEVEL Point ID:
C43C0010 Plant Spec Point Dese.:
SUPP POOL VALIDATED LEVEL Ceneric/Cond Desc.:
Suppression Pool Water Level Analog / Digital:
A Engr Units / Dig States:
FEET Engr Units Conversion:
Linear (Suppression Pool water icvel)
Minimum Instr Range:
0.10E+02 Maximum Instr Range:
0.600E+01 Zero Point
Reference:
COMPLX Reference Point Notes:
Zero is a 20' above mean sea level
. PROC or SENS:
P Number of Sensors:
3 (Suppression pool level inputs)
Accuracy wei hted average How Processed:
E Sensor Locations:
Level transmitters located @ RB 13' el Alarm / Trip Set Points:
LOW = -0.258E+01; HICH = -0.22SE+01 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A, need 2 2 inputs for C00D-Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
DRY Suppress [onpoollevelinputpc.ints Unique Svat;La Desc,:
default to actual values _when inputs exceed-signal ranges, i
F NUREG 1394, Rev. 1 C4 l:
Page 53 DATA POINT LIUllAllY llEFEllENCE FILE Date:-
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
112 CONC Point ID:
CACX1200 Plant Spec Point Dese.:
PC 112 CONC Cencric/Cond Desc.:
Drywell or Torus !!ydrogen Concentration Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
Linear (112 concent ration)
Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.300E+02 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors' 2 (l{ydrogen concentration inputs) llow Processed:
Max. corrected reading w/ valve line up Sensor Locations:
Detectors O BB 20' cl.
Alarm / Trip Set Points:
N/A' NI Detector Power Supply Cut-off Power Level N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:-
N/A Level Reference Leg:
N/A Unique System Desc.:
Processing includes the application of
. correction factors and compensates for temperature and pressure. 112 conc. inputs default to actual values when inputs exceed signal ranges, 112 sample lines run to DW 100', 50' & 6'; Torus -l'e1.
i-NUREC 1394, Rev. I c4 i
j l
wmwe sew (-
I Page 54 i
i DATA POINT LIllRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BKl Data Feeder:
N/A NRC ERDS Parameter:
02 CONC Point ID:
CACX1210 Plant Spec Point Desc.:
PC 02 CONC Ceneric/Cond Desc.:
Drywell or Torus Oxygen Concentration Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
Linear (02 concentration)
Minimum Instr Range:
0.000E+00 Maximum Instr Rante:
0.250E+02 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC c'
'tNS:
P Number of Sensors:
2 (Oxygen concentration inputs) llow Processed:
Max. corrected reading w/ valve line up Sensor Locations:
Detectors @ RB 20' el.
Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Processing includes the application of correction factors and compensates for temperature and pressure. 02 conc. inputs default to actual values when inputs exceed signal ranges.
02 sample lines run to DW 100', 50' & 6'; Torus l'e1.
i NUREG 1394, Rev. 1 0-4 p
Page 55 DATA POINT LIBRARY REFERENCE FILE Da'e:
05/15/92 Reactor Unit:
BKl Data Feeder:
N/A NRC ERDS Parameter:
CST LEVEL Point ID:
C0_LA005 Plant Spec Point Desc.:
CONDENSATE STORACE TANK LEVEL r
Generic /Cond Dese.:
Condensate Storage Tank Level Analog / Digital:
A i
Engr Units / Dig States:
FTDEC Engr Units Conversion:
Linear (CST 1cvel): 1 ft = 15625 gallons Minimum Instr Range:
0.000E400 Maximum-Instr Range:
0.320E+02 Zero Point
Reference:
TNKBOT Reference Point Notes:
Tank bottom is 20' above mean sea level.
PROC or SENS:
S Humber of Sensors:
1 Ilow Processed:
N/A r
Sensor Locations:
CST tank Alarm / Trip Set Points:
- 0W = 0.120E+ 02 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW /IIICl!
Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
DRY Unique System Desc.;
CST tank level points defaults to actual value when input exceeds signal range.
Each unit's 500,000 gallons capacity tank can be cross connected to the other unit, A standpipe reserves 100,000 gallons for f
use by llPCI and RCIC.
NUREG 1394, Rey, 1-C4 L
Page 56 DATA POINT LIDil Ally llEFEllENCE FILE Date:
05/15/92 Reactor Unit:
BKl Data '/eeder:
N/A NRC EROS Parameter:
WIND SPEED Point 1D:
WE_MA001 Plant Spec Point Dese.:
UPPER WIND SPEED Ceneric/Cond Desc.:
Wind Speed at the Reactor Site Analog / Digital:
A Engr Units / Dig States:
MPli Engr Units Conversion:
Telemetry from Meteorological Tower Minimum Instr Range:
0.000E+00 Maximum Inser Range:
0.100E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 llow Processed:
N/A Sensor Locations:
Het Tower at 104.6 A ters above base.
Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn *on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level _ Reference Leg:
N/A Unique System Desc.:
The Met tower base is located 1400' NE of reactor complex & 20' above mean sea level NURECal394, Rev. 1 C-4
Page 57 DATA POINT-LIllitAltY IIEFEllENCE FILE Date:
05/15/92 Reactor Unit BKl Data reeder:
N/A NRC ERDS Parameter:
WIND SPEED
~
Point ID:
WE_MA006 Plant Spec Point Desc.:
LOWER WIND SPEED Generic /Cond Desc.:
Wind Speed at the Reactor Site i
Analog / Digital:
A Engr Units / Dig States:
MPil Engr Units Conversion:
Telemetry from Meteorological Tower i
Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.100E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
.N/A Sensor Locations:
Met Tower at 11.5 meters above base.
- Alarm / Trip Set Points:-
N/A NI Detector Power Supply-Cut off Power Level:
N/A NI Detect-t Power Supply Turn on P wer Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A
' Level Reference Leg:
N/A Unique System Dese.:
t The Met tower base is located 1400' NE of reactor complex & 20' above mean sea level
-NUREG-1394,-Rev. 1 C4
Page 58 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK1 Data Feeder:
N/A NRC ERDS Parameter:
WIND DIR Point _ID:-
WE_MA003 Plant Spec Point Desc.:
UPPER WIND DIRECTION
-Generic /Cond Desc.:
Wind Direction at the Reactor Site Analog / Digital:
A E~gr Units / Dig States:
DECFR Engr Units Conversion:
TelemetryfrombeteorologicalTower Minimum Instr Range:
0.000L 00 Maximum Instr Range:
0.360E+03 Zero-Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How-Processed:
N/A Sensor Locations:
Met Tower at 104.6 meter above base.
Alarm / Trip Pet-Points:
N/A NI Detector Power Supply
~ Cut off-Power Level; N/A NI Detec'er Power Supply Turn on Power Level:
N/A Instrument Itt4ute Mode:
N/A Temperature Cety nsat;on For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
The Met tower base is located 1400' NE of reactor complex & 20' above mean sea level l
NUREC-1394, Rev. 1 C-4
Page 59_
)
DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BKl
^
Data Feeder:
N/A NRC ERDS Parameter:
WIND DIR Point ID:
WE_MA004 Plant Spec Point Desc.:
LOWER WIND DIRECTION Ceneric/Cond Desc.:
Wind Direction at the Reactor Site Anaivg/ Digital:
A Engr Units / Dig States:
DECFR Engr Units Conversion:
Telemetry from Meteorological Tower Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.360E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Setisors:
1 ov Processed:
N/A
. nsor Locations:
Met Tower at 11,5 meters above base.
' a rm/Trr,r Set Points:
N/A N Detector Power Supply
.ut off Power Level:
N/A NI Detector Power Supply Turn on Pover-Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Jnique System Det.:
i The Met tower base is located 1400' NE of reactor complex & 20' above mean sea level f
i
.NUREG-1394, Rev. 1 C-4 l
l:
Page 60-
-DATA POINT LIBRARY hEFERENCE FILE Date:
05/15/92 Reactor Unit:
BR1 Data Feeder:
N/A NRC ERDS Parameter:
STAB CLASS Point ID:
WE_MC001 Plant Spec Point Desc.:
NUMERIC PASQUILL STABILITY CLASS Ceneric/Cond Desc.:
Air Stability at the Reactor Site Analog / Digital:
A Engr' Units / Dig States:
STABI Engr Units Conversion:
Telemetry from Meteorological Tower Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.700E+01 Zero Point
Reference:
COMPLX Reference Point Notes:
Zero means dTemp average was out of range.
PROC or SENS:
P Number of Sensors:
2 liow Processed:
Weighted-average of 2 Met Tower inputs Sensor Locations:
Met Tower @ 10.2 and 103.2 above base Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power. Level:
N/A
- NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A, need 2 2 ir. puts for COOD Temperature Compensation Far DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
The two differential temperature inputs are equally weighted in the average, The dTemp range is -5 to +10 DEG C/100M.
g The Met tower base is located 1400' NE of reactor complex & 20' above mean sea level i
t l
NUREG 1394, Rev. 1 C-4
i Teu
~?
i ENCLOSURE 3 DATA POINT LIBRARY BRUNSWICK STEAM ELECTRIC PLANT UNIT 2 l
l' 1
l
?
\\
1.
1 I
(1634GLU) l l
Page 61 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
NI POWER RNC Point ID:
C51C0010 Plant Spec Point Dese.:
RX VALIDATED POWER -READOUT Ceneric/Cond Dese.:
Nuclear Instruments, Power Range Analog / Digital:
A Engr Units / Dig States:
Engr Units-Conversion:
Liaear (APRM reading); 1% = 24.36 MWt Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.125E+03 Zero PoirtL
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
6 (APRM inpats)
How Processed:
APRM Weighted average
- Cain Adj Factor Sensor Locations:
APRM signals to Control Room meters Alarm / Trip Set Points:
LOW = 0.300E+1 NI Detector Power Supply Cut off Power Level:
N/A NI Detector l'ower Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A, need 2 2 inputs for C00D Temperature Compensation For DP Transmitters:
N/A
-Level Reference Leg:
N/A Unique System Desc.:
Cain Adj Factor is processed from various heat-balance related sensors.
APRM input points default ta_ actual values when inputs exceed signal ranges, i
)
l NUREC-1394, Rev. 1 C-4
i Page 62 l
DATA POINT LIBRARY REFERENCE FILE Date:
D5/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
NI INTER RNC Point ID:
N/A Plant Spec Point Desc..
N/A Ceneric/Cond Desc.:
Nuclear Instruments, Intermediate Range Analog / Digital:
A Engr Units / Dig States:
AMP Engr Units Conversion:
N/A Minimum Instr Range:
N/A Maximum Instr Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
N/A Number of Sensors:
N/A How Processed:
N/A Jensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off' Power Level:
'.UA NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
This parameter is not monitored at BK2.
l l
NUREC-1394, Rev. 1 C-4
Page 63
- DATA POINT LIBRARY REFERENCE FILE Date 05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS-Parameter:
NI SOURC RNC Point ID:
C51NA021 Plant Spec Point Desc.:
hRMACOUNTRATE Generic /Cond Desc.:
Nuclear Instruments Source Range Analog / Digital:
A Engr Units / Dig States:
C/SEC Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E+00 Maxis.um Instr Range:
0.100E+07 Zero-Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number'of Sensors:
1 How Processed:
N/A Sensor Locations:
SRM is at core location 12-33.
Alarm / Trip Set Points:
LOW = 0.500E+01; HIGH = 0.500E+06 NI Detector Fower Supply-Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW /l!ICl!
Temperature-Compensation
-For DP. Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Signal is the same that drives the "A" SRM meter in the control room.
SRM point defaults to appropriate range limit value when input exceeds signal range.
NUREG-1394, Rev. 1 C-4
Page 64-DATA - POINT LIBRARY REFERENCE FILE-Date:
05/15/92 Reactor Unit.
BK2-Data Feeder:
N/A NRC ERDS Parameter:
NI SOURC RNG Point ID:
C51NA022 Plant Spec Point Desc.:
SRM B COUNT RATE-Generic /Cond Desc.:
Nuclear Instruments. Source Range Analog / Digital:
A Engr Units / Dig States:
C/SEC Engr Units _ Conversion:
Antilog-10 Minimum Instr Range:
0.100E+00 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A
-Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
SRM is at core location 28-41.
Alarm / Trip Set Points:
LOW = 0.500E+01; HIGH = 0.500E+06 NI Detector Power Supply Cut off Power-Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Signal is the same that drives the "B"
SRM meter in the control room.
SRM point L
defaults to appropriate range limit value L
when input exceeds signal range, i
l I
NUREG-1394, Rev. 1 C-4
Page 65
. DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS' Parameter:
NI SOURC RNG Point ID:
C51NA023 Plant Spec Point Desc.:
SRM C COUNT RATE Ceneric/Cond Desc.:
Nuclear Instruments, Source Range Analog / Digital:
A Engr Units / Dig States:
C/SEC Engr Units Conversion:
Antilog-10 Minimum Instr Range:
0.100E+00 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A
. PROC or SENS:
S Number of' Sensors:
1 How Processed:
N/A Sensor Locations:
SRM is at core location 36-25.
Alarm / Trip Set Points:
LOW = 0.500E+01; HICH = 0.500E+06 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Signal is the same that drives the "C" SRM meter in the control room.
SRM point defaults to appropriate range limit value when input exceeds signal range.
i l
NUREG 1394, Rev. 1 C-4
Page 66 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BR2
. Data Feeder:
N/A NRC ERDS Parameter:
NI SOURC RNG Point ID:
C51NA024 Plant Spec Point Desc.:
SRM D COUNT RATE Ceneric/Cond Desc.:
Nuclear Instruments Source Range l
Analog / Digital:
A l
i Engr Units / Dig States:
C/SEC l
Engr Units Conversion:
Antilog-10 Minimum Instr Range:
0.100E+00 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference-Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 Now Processed:
N/A Sensor Locations:
SRM is at core locatien 20 17.
Alarm / Trip Set Points:
LOW = 0.500E+01; ilIGH = 0.500E+06 NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /IIICll Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.-
Signal is the same that drives che "D" SRM meter in the control room.
SRM point defaults to appropriate range limit value l.
l when input exceeds signal range.
I NUREC-1394, Rev. 1 C-4
l Page 67 j
DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2-Data Feeder:
N/A NRC ERDS Parameter:
REAC VES LEV Point ID:
B21C0010 Plant Spec Point Desc.:
RPV VALIDATED WTR LEVEL -READOUT Generic /Cond Desc.:
Reactor Vessel Water Level Analog / Digital:
A Engr Units / Dig States:
IN Engr Units Conversion:
Linear (RPV water level)
Minimum Instr Range:
-0.150E+03 Maximum Instr Range:
+0.550E+03 Zero Point
Reference:
TAF Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
15 (RPV level inputs)
How Processed:
Accuracy weighted average Sensor Locations:
Level transmitters on RB 20' & 50' el.
Alarm / Trip Set Points:
LOW = 0.163E+03; HICH = 0.208E+03 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A, need a 2 inputs for C00D Temperature Compensation l
For DP Transmitters:
Y Level Reference Leg:
WET
-Unique ~ System Desc.:
The processing compensates for Drywell and
[
Reactor Building temperatures, and Reactor i
pressure, calibration conditions, and Recirculation pump operating status.
RPV water level input points default to actual l
values when inputs exceed signal ranges.
NUREG-1394, Rev. 1 C-4
Page 68 DATA ' POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
MAIN FD FLOW Point ID:
C5108003 Plant Spec Point Dese,:
TOTAL FEEDWATER FLOW SMOOTHED Ceneric/Cond Desc.:
Feedwater Flow into the Reactor System Analog / Digital:
A Engr Units / Dig States:
MLB/HR l
Engr Units Conversion:
Square root (feedwater flow)
Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.120E+02 Zero Point
Reference:
N/A Reference Point Notes:
h/A
]
PROC or SENS:
P Number of Sensors:
2 (feedwater flow inputs)
Ilow Processed:
Sum smoothed, density compensated flows Sensor Locations:
FE @ #5 FW heater outlet; FT @ TB 20'el Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply' N/A Turn on Power Level:
. Instrument Failure Mode:
N/A, need 2 2 input for COOD Temperature Compensation For DP Transmitters:
Y Level Reference Leg:
N/A Unique System Desc.;
Processing includes smoothing with a 30 second time constant and compensation for feedwater temperature and reactor pressure Feed flow input points default to actual values when inputs exceed signal ranges.
NUREG-1394, Rev. 1 0-4
Page 69 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2-Data Feeder:
N/A NRC ERDS Parameter:
RCIC FLOW Point ID:
E51FA004 Plant Spec Point Desc..
RCIC PUMP DISCHARCE FLOW Generic /Cond Dese.:
Reactor Core Isolation Cooling Flow Analog / Digital:
A Engr Units / Dig States:
GPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.500E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before test flow line; FT @ RB 17'el iiICH=0.410E+03 Alarm / Trip Set Points:
NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
[0W/HICH Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc..
RCIC flow input point defaults to actual value when input exceeds signal range.
Temperature correction curve for flow from the DP transmitter does not exist.
NUREC 1394, Rev. 1 C-4
Page 70
-DATA POINT LIBRARY REFERENCE FILE l
Date:
05/15/92
-Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
RCS PRESS Point ID:
B21C0210 Plant Spec Point Desc.:
RPV VALIDATED PRESSURE--READOUT Generic /Cond Desc.:
Reactor Coolant System Pressure Analog / Digital:
A Engr Units / Dig States:
PSIG Engr Units Ccaversion:
Linear (RPV pressure)
Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.150E+04 Zero Point
Reference:
N/A Reference Point-Notes:
N/A PROC or SENS:
P Number of Sensors:
11 (RPV pressure inputs)
How Processed:
Accuracy-weighted average Sensor Locations:
Pressure transmitters on RB 20' & 50'el Alanm/ Trip Set Points:
IIICH = 0.1045E+04 NI Detector Power Supply Cut-off Power Level:
N/A NI Detector. Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A, need 2 2 inputs for COOD Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
RPV pressure input points default to actual values when inputs exceed signal ranges.
NUREC 1394, Rev. 1 C-4
Page 71 DATA POINT LIBRARY REFERENCF.
FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
HPCI FLOW Point ID:
E41FA001 Plant Spec Point Dese,:
HPCI PUMP DISCHARGE FLOW Generic /Cond Desc.:
High Pressure Coolant Injection Flow Analog / Digital:
A Engr Units / Dig States:
KCFM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.500E+01 Zero Point
Reference:
N/A Reference Point: Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before test flow line; FT @ RB 17'el Alarm / Trip Set Points:
HICH = 0.430E+01 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Dese.:
HPCI flow input point defaults to actual value when input exceeds signal range.
Temperature correction curve for flow from the DP transmitter does not exist.
NUREC-1394, Rev. 1 C-4
Page 72 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
LPCI FLOW Point ID:
EllFA005 Ptsnt Spec Point Desc.:
RHR LOOP A SYSTEM FLOW Generic /Cond Desc.:
Low Pressure Coolant Injection Flow
-Analog / Digital:
A Engr Unita/ Dig States:
RCPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.300E+02
.Zero Point
Reference:
N/A Reference Point Notes:
N/A
)
PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before Torus or DW Spray; FT @ RB 17'el Alarm / Trip Set. Points:
N/A NI Detector Power Supply.
Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
RHR A flow input point defaults to the actual value when input exceeds the signal range. Temperature correction curve for flow from the DP transmitter does not exist.
NUREG-1394, Rev. 1 C-4
Page 73 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 j
Data Feeder:
N/A j
NRC ERDS Parameter:
LPCI FLOW Point ID:
EllFA006 Plant Spec Point Desc.:
RHR LOOP B SYSTEM FLOW Generic /Cond Desc-.:
Low Pressure Coolant Injection Flow Analog / Digital:
A Engr Units / Dig States:
KCPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.300E402 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 Ilow Processed:
N/A Sensor-Locations:
FE before Torus or DW Spray; FT @ RB 17'el Alarm / Trip _ Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply i
Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /HICH Temperature Compensation l
'For DP Transmitters:
N-
-Level Reference Leg:
N/A Unique System Desc.-
l l
RHR B flow input point defaults to the actual value when input exceeds-the signal range.
Temperature correction curve for flow f rom the DP transmitter does not exist.
NUREG 1394, Rev. 1 C-4
Page 74 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A 1
NRC ERDS Parameter:
CR SPRAY FL Point ID:
E21FA001 Plant Spec Point Desc.;
CORE SPRAY PUMP A FLOW Ceneric/Cond Desc.*
Core Spray Cooling System Flow Analog / Digital:
A Engr Units / Dig States:
KCPM Engr Units Conversion:
Square root Minimum Instr Range:
0.000E400 Maximum Instr Range:
0.700E+01 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before test flow line; PT @ RB 17'el Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /llICil Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
Core Spray A flew input point defaults to tne actual value when input exceeds the signal range.
Temperature correction curve f or flow f rom the DP transmitter does not exist.
NUREG-1394, Rev. 1 C-4
Page 75 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A j
NRC ERDS Parameter:
CR SPRAY FL Point ID:
E21FA002 Plant Spec F, x Desc.:
CORE SPRAY PUMP B FLOW Ceneric/Cond Desc.:
Core Spray Cooling System Flow Analog / Digital:
A Engr Units / Dig States:
KCPM Engr Units Conversion:
Square root
-Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.700E+01 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
FE before test flow line; FT @ RB 17'el Alarm / Trip Set Points:
N/A
' N'A Detector-Power Supply Cut off Power Level:
N/A c.
NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW /HICH
-Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Dese.:
Core Spray B flow input point defaults to the actual value when input exceeds the signal range.
Temperature correction curve for flow f rom the DP transmitter does not exist.
NUREC-1394, Rev. 1 C4
c:
Page 76
-DATA POINT - LIBRARY REFERENCE FILE Date:
05/15/02
' Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
N/A Plant Spec Point Desc.:
N/A Generic /Cond Dese,:
Drywell Floor Drain Sump Level Analog / Digital:
N/A Engr Units / Dig States; IN Engr Units Conversion:
N/A
-Minimum Instr Range:
N/A Maximum Instr Range:
N/A Zero Point
Reference:
N/A f
Reference Point Notes:
N/A PROC or SENS:
N/A Number of Sensors:
N/A
!!ow Processed:
N/A Sensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For.DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
This parameter is not monitored at BK2.
L l
NUREG 1394, Rev. 1 C-4
Page 77-DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
Ch2 Data Feeder:-
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
D17R0303 RBROOFNOBCASRAbCACAT12643 Plant Spec Point Desc.:
Ceneric/Cond Desc.;
krdioactivity of Released Casses Analog / Digital:
A Engr Units / Dig States:
CPM Engr Units Conversion:
Antilog 10 Minimum-Instr Range:
0.100E+02 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes?
N/A PROC. or SENS:
P Number of Sensors:
1 How Processed:
Alarm checked Sensor Locations:
Line to U2 RB vent; sensor @ RB 166'el Alarm / Trip Set Points:
HIGH = Variable limits per ODCM NI Detector-Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A
. Instrument Failure Mode:
N/A
--Temperature Compensation-For DP Transmitters:
N/A Level-Reference Leg:
N/A Unique System Dese.:
RB rad input point defaults to appropriate range limit values, when input exeeds signal range.
EFF_CAS_ RAD (RB2)
=
D17R0303
- VA_FA104
- CONT 1010 ODCM ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 10CFR50 36a and App I.,
40CFR190.
NUREG-1394, Rev. 1 C-4
Page 78 DATA POINT LIBRARY-REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
VA_FA104 Plant Spec Point Desc.:
U-2 RX DLDC ROOF VENT FLOW Generic /Cond Desc.:
Reactor Building Vent Flow Rate Analog / Digital:
A Engr Units / Dig States:
KSCFM Engr Units Conversion:
Linear Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.200E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
.__ _= 0.200E+02 EAlarm/ Trip Set Points:
LOW HI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A
_evel Reference Leg:
N/A Unique System Dese.:
RB flow input point defaults to appropriate range limit values, when input exeeds signal range.
EFF_CAS_ RAD (RB2)
=
D17R0303
- VA_FA104
- CONT 1010 NUREG-1394, Rev. 1 C4
Page 79 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
CONT 1010 Plant Spec Point Desc.:
U+2 RB VENT MON EFFIC FAC Ceneric/Cond Desc.;
RB Vent Rad Monitor Efficiency Analog / Digital:
A Engr Units / Dig States:
(see below)
Engr Units Conversion:
N/A Minimum Instr Range:
N/A Maximum Instr Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
0
!!ow Processed:
Equated to constant Sensor Locatione:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference _ Leg:
N/A Unique System Dese,:
Engineering units are (pCI/SEC)/(CFM* CPM),
Radiation monitor efficiency changes with l
calibration.
EFF GAS RAD (RB2) =
D17R0303
- VA FA104 *-CONT 1010 l~
{
l-NUREG 1394, Rev. 1 C-4
-Page 80 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit':
BR2
-Data Feeder:
N/A NRC ERDS Parameter:
EFF GAS RAD
)
Point ID:
Dl?R0306 j
' Plant Spec Point Desc.:
Ul RB ROOF NOB CAS RAD Generic /Cond Dese.:
Radioactivity of Released Casses Analog / Digital:
A Engr Units / Dig States:
' Engr Uaits Conversion:
Antilog 10 i
Minimum Instr Range:
0.100E+02 Maximum Instr Range:
0,100E+07
-j
'Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 How Processed:
Alarm checked Sensor Locations:
Line to Ul RB vent; sensor @ RB 166'el l
Alarm / Trip Set Points:
HICl! = Variable limits per ODCM NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply l
Turn on Power Level:
N/A Instrument. Failure Mode:
N/A Temperature Compensation l~
For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
RB rad input point defaults to appropriate range limit values, when input-exeeds signal range.
EFF_CAS_ RAD (RBl) =
D17R0306
- VA FA004
- CONT 1000 l-ODCM ensures compliance with T.S..
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 10CFR50 36a and App I.,
40CFR190.
l NUREG 1394 Rev. 1 C-4 L
Page 81 DATA POINT LIBRARY REFERENCE FILE-Date:
05/15/92 Reactor Unit:
BC2 Data Feeder:
N/A NRC ERDS Parameter:
EFF GAS RAD.
Point ID:
VA_FA004 Plant Spec Point Desc-:
U-! RX BLDG ROOP VENT FLOW Ceneric/Cond Dese,:
Reactor Building Vent Flow Rate l
Analog / Digital:
A Engr Units / Dig States:
RSCFM Engr Units Conversion:
Linear Minimum _ Instr Range:
0.000E+00 Maximum Instr Range:
0.200E+03 l
2ero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S-Number of Sensors:
1 How Processed:
N/A Sensor Locaticas:
l Alarm / Trip Set Points:
LOW = 0.200E+02 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A
-Temperature-Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
RB flow input point defaults to appropriate range limit values, when input exeeds signal range ~
EFF_CAS_ RAD (RB1) =
Di?R0306
- VA,,FA004
- CONT 1000 NUREG-1394, Rev. 1 C-4
Page 82 DATA POINT -LIBRARY REFERENCE FILE i
Date:
05/15/92 Reactor Unit:
BK2 Data-Feeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:.
CONT 1000 Plant Spec Point Desc.:
U-l RB VENT MON EFFIC FAC Ceneric/Cond'Desc.:
RB Vent Rad Monitor Efficiency Analog / Digital:
A Engr Units / Dig States:
(see below)
Engr Units Conversion:
N/A Minimum Instr Range:
N/A Maximum Instr Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
0 How Processed:
Equaied to constant Sensor Locations:
N/A Alarm / Trip' Set' Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A l
NI Detector Power Supply Turn on Power Level; N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A l-
. Unique System Desc.:
Engineering units are (pCI/SEC)/(CFM* CPM),
Radiation monitor efficiency changes with y
calibration.
EF a'_CAS_ RAD (RE l )
=
D17R0306
- VA_FA004
- CONT 1000 NUREG 1394, Rev. 1 C-4
.Page 83 DATA POINT - LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
EFF CAS RAD Point ID:
D17R0307 Plant-Spec Point Desc.:
TURB BLDC VENT RAD STAT D12-MS80 Generic /Cond Desc.:
Radioactivity of Released Casses Analog / Digital:
A Engr Units / Dig States:
pCI/S Engr Units Conversion:
Antilog-10 Minimum Instr Range:
0,100E+01 Maximum Instr Range:
0,100E+13 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 liow Processed:
Alarm checked Sensor Locations:
I.ine to U2 TB vent; sensor @ CTB 29'el Alarm / Trip Set Points:
111011 = Variable limits per ODCM NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
ODCM ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 10CFR50 36a and App I, 40CFR190.
U2 TB vent radiation release input point defaults to the appropriate range limit value when input exceeds signal range.
NUREC-1394, Rev. 1 C-4
Page 84 DATA POINT LIBRARY - REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:-
EFF CAS RAD
-Point ID:
D17R0309 Plant Spec Point Dese.:
Ul TB VENT RAD STAT ID12 MS80 Generic /Cond Desc.:
Radioactivity of Released Casses Analog / Digital:
A Engr Units / Dig. States:
pCI/S Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E401 Maximum Instr Range:
0.100E+13 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P
' Number of Sennors:
1 How Processed:
Alarm checked Sensor Locations:
Line to U1 TB vent; sensor @ CTB 29'el Alarm / Trip Set Points:
HIGH = Variable limits per ODCM NI Detector Power Supply-Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP-Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
ODCM ensures compliance with T.S..
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 10CFR50 36a and App I., 40CFR190.
U1 TB vent radiation release input point defaults to the appropriate range limit value when input exceeds signal range.
NUREC-1394, Rev. 1 C-4 i
Page 85 DATA POINT LIBilAllY llEFEllENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC LRDS Paramecer:
EFF CAS RAD Point ID:
D17R0311 Plant Spec Point Dese.:
STACK EFFLUENT RAD ST T D12 MS80 Generic /Cond Dese.:-
Radioactivity of Released Casses
)
Analog / Digital:-
A Engr Units / Dig States:
pCI/S 5
Engr Units Conversion:
Antilog 10 Minimum tra tr Range:
0.100E+02 Maximum Instr Range:
0.1000+14 Zero Poln6 Neference:
N/A' Reference Point Notes:
N/A PROC or SENS:
P Humber of Sensors:
1 Ilow Processed:
Alarm checked Sensor Locatians:
Line to main stack; sensor @ DGB 6'el Alarm / Trip Set Points:
111011 = Variable limits per ODCH NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level N/A Instrument Failure Mode:
N/A Temperature. Compensation For DP Transmitters:
N/A Level Reference Legi N/A Unique System Dese.:
ODCH also ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11,4 and 3/4.12 A 100FR20, 10CFR50 36a and App I..-40CFR190.
t Stack radiation release input point defaults to the appropriate range limit value when input exceeds signal range.
NUREG 1394, Rev. 1 C-4 I
.._a_,
Page 86 DATA POINT LIDilARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
bK2 Data Feeder:
N/A NRC ERDS Parameter:
EFF LIQ RAD Point ID:
D17R0401 Plant Spec Point Desc.:
SERVICE WTR RAD STAT Dl?RE*N008 Generic /Cond Desc.:
Radioactivity of Released Liquids Analog /Digitalt-A Engr Units / Dig States:
CPS Engr Unitt Coc*ersion:
Antilog 10 Minimum Instr Range:
0.100E+00 Maximum Instr Range:
0.100E407 Zero Print
Reference:
N/A
- 1..drence Point Notes:
N/A PROC or SENS:
P
-Number of Sensors:
I flow Processed:
Alarm checked Sensor Locations:.
RB Alarm / Trip Set Points:
IIICil = Variable limits per ODCM
. Cut off Power Level:pply NI Detector Power Su N/A Turn on Power Level:pply NI Detector Power Su N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique' System Desc.:
ODCM also ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4,12 &
100FR20, 10CFR50 36i and App I.,
40CFR190.
Sevice water rad l'.put point def aults to appropriate limit ange value when input exceeds signal range, Up to 5 pumps may be in service w/ flow =ab.at 8000 gpm/ pump.
Sensor efficiency is 0.406E 06 pCI/ml/ cps.
-NUREG 1394, Rev. 1 C-4
. ~.
Page 87 DATA l'0IN T Lillll AltY ltEFEltENCE FILE Date:
05/15/92 Reactor Unit:
BR2 Data Feeder:
N/A NRC ERDS Parameter:
CND A/E RAD Point ID:
D17E0210 P* ant Spec Point Dese.:
SJAE RAD STAT Ceneric/Cond Desc.:
Condenser Air Ejector Radioactivity AnaloC/ Digital:
A Engr Units / Dig States:
N/A Engr Units Conversion:
Tristate Minimum Instr Range:
0 Maximum Instr Range:
2 e
Zero Point
Reference:
COMPLX Ref erence Poir-Notes:
0 = Normal; 1 = Caution; 2 = Alarm PROC or SENS:
P Number of Sensors:
0 llow Processed:
Alarm status checked Sensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Dese,.
Value represents the more limiting status of the two SJAE rad alarm points:
D17R0201 and D17R0202, SJAE radiation input points default to the appropriate range limit values when inputs exceed signal ranges.
NUREG 1394, Rev. 1 C-4
DATA POINT LIllll Ally llEFERENCE FILE Date:
05/15/92 Reactor Unit:
l'I2 Data Peeder:
N/A NRC ERDS Parameter:
CND A/E RAD Point ID:
D17R0201 Plant Spec Point Desc.:
SJAE RAD MON A STAT D12RE N004A Generic /Cond Desc.:
Condenser Air Ejector Radioactivi,-
Analog / Digital:
A Engr Units / Dig States:
MR/llR Engr Units Conversion:
Antilog*10 Minimum Instr Range:
0.100E+01 Maximum Inctr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processeit Alarm checked Sensor Locatic a:
TB Alarm / Trip Set Points:
!!ICil = Variable per ODCM m_t "I Ce.aeror Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
ODCM also ensures compliance with T.S.:
3/4.11.1, 3/4.11.2, 3/4.11.4 and 3/4.12 &
10CFR20, 10CFR50 36a and App I.,
40CFR190.
SJAE radiation input point defaults to the appropriate range limit value when input exceed signal range.
Sensor efficiency, units of (pCI/sec)/(mR/hr cfm) changes weekly with gas mix.
Limits are based conservatively on the worst gas mix.
NUREG 1394, Rev. 1 C4
Page 89 l
DATA Pull'T LI Dil AltY llEFEllENCE F11.E Date:
05/15/92 Reactor Unit:
bE2 Data Feeder:
N/A KRC ERDS Parameter:
CND A/E RAD Point ID:
D17R0202 Plant Spec Point Desc.t SJAE RAD MON B STAT D12RE N004B Generic /Cond Desc :
Condenser Air Ejector Radioactivity Analog / Digital:
A Engr Units / Dig States:
Mn/lin Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E401 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Ref etence Point 1:otes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
TB Alarm / Trip Set Points:
111C11 = Variable per ODCM NI Detector Power Supply Cut off Power Level:
N/A
~
NI Detector Power Supply Turn-on Power Level:
N.'A instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.;
ODCM also ensures compliance with T.S.:
3/4,11,1, 3/4.!! 2, 3/4.11.4 and 3/4.12 6 10CFR20, 10CFR50 36a and App I, 40CFR190.
SJAE radiation input point defaults to the appropriate range limit value when input exceed signal range.
Sensor efficiency, units of (pC1/sec)/(mR/hr-cfm) changes weekly with gas mix.
Limits are based conservatively on the worst gas mix.
NUREG-1394, Rev, 1 C4
Page 90 DATA POINT LIBilAltY ItEFEllENCE FILE j
Date:
05/15/92 Reactor Unit:
Im2 Data Feeder:
N/A NRC ERDS Parameter:
DW RAD Point ID:
D17E0611 Plant Spec Point Desc.:
PRI CNTMT RAD STAT Ceneric/Cond Dese.:
Radiation Level in the Drywell Analog / Digital:
A Engr Units / Dig States:
N/A Engr Units Conversion:
Tristate a
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
CvMPLX Reference Point Notes:
0 = Normal; 1 = Caution; 2 = Alarm PROC or SENS:
P Number of Sensors:
0 Ilow Processed:
Alarm status checked Sensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Dese.:
Value represents the more limiting status of the four drywell rad alarm points:
D17R0610, D17R0611, D17R0612 and D17R0613.
DW radiation input points default to the appropriate range limit values when inputs exceed signal ranges.
NUREG 1394, Rev. 1 C-4
Page 91 DATA POINT LIDR Ally REFEllENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
DW RAD Point ID:
Dl?R0610 Plant Spec Point Dasc.:
PC !!I RNC 30' RAD STAT D2?RM4195 Generic /Cond Dese,:
Radiation Level in the Drywell Analog / Digital:
A Engr Units / Dig States:
R/llR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E 01 Maximum Instr Range:
0.100E+0B Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
In Drywell @ RU 30' el.
Alarm / Trip Set Points:
111011 = 0.100E+ 03 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Drywell radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
HUREC 1394, Rev. 1 C-4
.im Page 92 DATA PDINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
DW RAD Point ID:
D17R0611 Plant Spec Point Desc.:
PC 111 RNG 51' RAD STAT D22RH4196 Ceneric/Cond Desc.:
Radiation Level in the Drywell Analog / Digital:
A Engr Units / Dig States:
R/HR Engr Units Conversion:
Antilog 10 Hinimum Instr Range:
0.100E+01 Haximum Instr Range:
0.100E408 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:.
P Number of Sensors:
1 Ilow Processed:
Alarm checked Sensor Locations:
In Drywell @ RB 57' el.
Alarm / Trip Set Points:
111C11 = 0.100E+ 0J NI Detector Power Supply Cut off Power Level:
N/A' NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A-4 Level Reference Leg:
N/A
-Unique System Desc.:
Drywell radiation input point ~ defaults to the appropriate range limit value when input exceed signal ranges.
NUREC 1394,-Rev. 1 C4
. - ~ - - -
-. ~
Page 93 DATA POINT LIllllAllY llEFEllENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
DW RAD Point ID:
D17R0612 Plant Spec Point Desc.:
PC III RNC 23' RAD STAT D22RM4197 Generic /Cond Desc.;
Radiation Level in the Drywell Analog / Digital:
A Engr Units / Dig States:
R/llR Engr Units conversion:
Antilog 10 l
[
Hinimum Instr Range:
0.100E+01 Maximum Instr Range:
0.100E*08 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 Ilow Processed:
Alarm checked Sensor Locations:
In Drywell @ RB 23' el.
Alarm / Trip Set Points:
!!ICil = 0.100t+ 03 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation
.For DP Tranuitters:
N/A Level Reference Leg:
hA Unique System Dese.:
Drywell radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
NUREG 1394, Rev. 1 C4
Page 94 DATA POINT LIBRARY REFEllENCE FILE Date:
05/15/92 Reactor Unit:
BR2 Data Feeder:.
N/A NRC EROS Parameter:
DW RAD Point ID:
D11R0013 Plant Spec Point Desc.:
PC 111 RNC 57' RA9 STAT D22RH4198 Ceneric/Cond Desc.:
Radiation Level in the Drywell l /ii l
.Ana og D g ta :
A Engr Units / Dig States:
R/llR 1
I Engr Units Conversion:
Antilog 10-Minimum Instr Range:
0.100E+01
)
Maximum Instr Range:
0.100E+08 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor. Locations:
In Drywell @ RB 57' el.
Alarm / Trip Set Points:
111011 = 0.100E+ 03 NI Detector Power Supply Cut off Power Level:
N/A Turn on Power Level:pply NI Detector Power Su N/A i
Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A l
l Level Reference Leg:
N/A t
Unique System Dese.:
Drywell radiation input point defaults to 1
the appropriate range limit value when input exceed si nal ranges.
E NUREG 1394, Rev. 1 04
Page 95 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
liK2 Data Fecder:
N/A NRC ERDS Farameter:
MN STEAM RAD Point ID:
D17E0110 Plant Spec Point Desc.:
MSL RADIATION STAT Ceneric/Cond Dese.:
Radiation Level of the Main Steam Line AnaloE/ Digital A
Engr Units / Dig States:
N/A Engr Units Conversion:
Tristate Minimum Instr Range:
0 Haximum Instr Range:
2 i
Zero Point
Reference:
COMPLX Reference Point Notes:
0 = Normal; 1 = Caution: 2 = Alarm i
PROC or SENS:
P Number of Sensors:
0 Ilow Processed:
Alarm status checked Sensor Locations:
N/A Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A i
Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg N/A Unique System Dese,:
Value represents the more limiting status of the 4 main steam line rad alarm points:
D17R0101, Dl?R0102, D17R0103 and D17R0104.
MSL radiation input points default to the appropriate range limit values when inputs exceed signal ranges.
NUREG 1394, Rev. 1 0-4
_ _. ~. _ _ _. ~. _. _.. _.. _. _. _. -,...
Page 96 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
MN STEAM RAD Point ID:
D17R0101 Plant Spec Point Desc.:
MSL A RAD STATUS D12RE N006A Generic /Cond Desc.:
Radiation Level of the Main Steam Line Analog / Digital:
A Engr Units / Dig States:
MR/llR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E401 Maximum-Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
Near outboard isolat. valve @ RB 50'el Alarm / Trip Set Points:
!!ICll = Variable per Tech. Specs.
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
The Technical Specifications limits are based on background radiation which can change f requently due to flydrogen Injection.
Main Steam Line radiation inout point defaults to the appropriate range limit value when input exceed signal ranges.
NUREG 1394, Rev. 1 C-4
Page 97 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
MN STEAM RAD Point ID:
D17R0102 Plant Spec Point Desc.:
MSL B RAD STATUS D12KE N006B Ceneric/Cond Desc.:
Radiation Level of the Main Steam Line Analog / Digital:
A Engr Units / Dig States:
MR/IIR Engr Units Conversion:
Antilog 10 Minimum Instr Range:
0.100E+01 Maximum Instr Range:
0.100E+07 Zero Point Reference N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 Ilow Processed:
Alarm checked Sensor Locations:
Near outboard isolat, valve @ RB 50'el Alarm / Trip Set Points:
111 011 i Variable per Tech. Specs.
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument-Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Dese :
The Technical Specifications limits are based on-background radiation which can change f requently due to liydrogen Injection. Main Steam Line radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
NUREC 1394, Rev, 1 C4
Page 98 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
EK2 Data Feedert N/A NRC ERDS Parameter:
MN STEAM RAD Point ID:
D17R0103 Plant Spec Point Desc.:
MSL C RAD STATUS D12RE N006C i
Generic /Cond Dese.:
Radiation Level of the Main Steam Line l
Analog / Digital:
A Engr Units / Dig States:
tm/llR Engr Units Conversion:
Antilog 10 i
I Minimum Instr Range:
0.100E401 Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 llow Processed:
Alarm checked Sensor Locations:
Near outboard isolat. valve @ RB $0'el Alarm / Trip Set Points:
HICil = Variabic per Tech. Specs.
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A
-Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Dese.:
The Technical Specifications limits are based on background radiation which can l
change frequently due to Hydrogen Injection.
Main Steam Line radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
NUREG 1394,'Rev. 1 C4
_.. ~
f Page 99 DATA POINT LII3RARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter MN STEAM RAD Point ID:
D17R0104 Plant Spec Point Desc.:
MSL D RAD STATUS D12RE N006D Ceneric/Cond Desc.:
Radiation Level of the Main Steam Line Analog / Digital:
A Engr Units / Dig States:
MR/HR Engr Units Conversion:
Ant 11og 10 Minimum Instr Range:
0.100E+01-Maximum Instr Range:
0.100E+07 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
1 How Processed:
Alarm checked Sensor Locations:
Near outboard isolat. valve @ RB 50'c1 Alarm / Trip Set Points:
HIGH = Variabic per Tech. Specs.
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply
. Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
The Technical Specifications limits are based on background radiation which can change frequently due to Hydrogen Tnjection. Main Steam Line radiation input point defaults to the appropriate range limit value when input exceed signal ranges.
NUREG-1394, Rev. 1 C-4
~
Page 100 DATA POINT L111 rally llEFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
DW PRESS Point ID:
D2300010 Plant Spec Point Desc.:
DRYWELL VALIDATED PRESS READOUT Cencric/Cond Dese.:
Drywell Pressure Analog / Digital:
A Engr Units / Dig States:
PSIG Engr Units Conversion:
Linear (Drywell pressure)
Minimum Instr Range:
0.500E+01 Maximum Instr Range:
0.245E403 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
4 (Drywell pressure inputs) llow Processed:
Accuracy weighted average Sensor Locations:
PT located @ kB 24'e1.
Alarm / Trip Set Points:
111C11 = 0.180E+01 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A, need 2 2 inputs for COOD Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
Drywell pressure input points default to actual values when inputs exceed signal ranges.
NUREC-1394, Rev. 1 C4
Page 101 DATA POINT LIBilARY llEFERENCE FILE Date:
05/13/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
DW TEMP Point ID:
D23C0310 Plant Spec Point Desc.:
DRYWELL TEMPERATURE READOUT Generic /Cond Dese.:
Drywell Temperature r
Analog / Digital:
A Engr Units / Dig States:
DECF Engr Units Conversion:
Telemetry from Supp. Pool Temp. Hon. Sys Minimum Instr Range:
0.320E402 Haximum Instr Ras.ge:
0.350E403 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensora:
13 (Drywell temperature inputs) llow Processed:
Regional weighted or arithmetic average Sensor Locations:
TE's in drywell between 10' and 92' el Alarm / Trip Set Points:
HIGli = 0,300E+03 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Dese.:
Arithmetic average is used as a backup for the regionally weighted average.
NUREG 1394, Rev. 1 C4
Page 102 DATA POINT LIBRARY REFERENCE FILE Date:
05/15/92 j
i Reactor Unit:
BK2 i
Data Feeder:
N/A NRC ERDS Parameter:
SP TEMP Point ID:
D23C0210 Plant Spec Point Desc.:
POOL TEMP TREND /BAR/ READOUT Generic /Cond Desc.:
Suppresnion Pool Temperature Analog / Digital:
A Engr Units / Dig States:
DEGF Engr Units Conversion:
Telemetry.from Supp. Pool Temp. Hon.~Sys Minimum Instr Range:
0.320E402
.m.
Maximum Instr Range:
0.212?.+03 Zero Point
Reference:
"/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
24 (Suppression pool temperature inputs) iicw Processed:
Reginnal weighted or arithmetic averaEC Sensor Locations:
TE's in torus @ various azimuths Alarm / Trip Set Points:
111011 = 0.950E+02 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level N/A Instrument Failure Mode:
N/A Tem}.trature Compensation For DP Transmitters:
N/A l
n.
Level Reference Leg:
N/A Unique' System Desc.:
Arithmetic average is backup for regional-weighted average; maximum pool temp counts as one region, l
i l
l NUREC 1394, Rev. 1 C4
-,. -,. _.. _,, _., _ -, _ ~ ~ _, _. _ _ _ _. _ - - _ _. _ _.. _, _. - _ _. - - _ _, _ _ _ _ _, _..
Page 103 DATA POINT LIBRARY HEFERENCE FILE Date:
05/15/92 Reactor Unit:
EK2 Data Feeder:
N/A NRC ERDS Parameter:
SP LEVEL t
Point ID:
C4300010 Plant Spec Point Desc.:
SUPP POOL VALIDATED LEVEL
'Ceneric/Cond Desc :
Suppression Pool Water Level Analog / Digital:
A Engr Units / Dig States:
FEET Engr Units Conversion:
Linear (Suppression Pool vater level)
Hinimum Instr Range:
0.10E+02 Maximum Instr Range:
0.600E401 Zero Point
Reference:
COMPLX Reference Point Notes:
Zero is a 20' above mean sea level PROC or SENS:
P (Suppreselon pool level inputs)
Number of Sensors:
2 llow' Processed:
Accuracy weighted average Sensor Locations:
Level transmitters located @ RB 13' e1 Alarm / Trip Set Points:
LOW =
- 0. 2 58E4 01 ; 111011 =
- 0. 225E + 01 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply l.
Turn on Power Level:
N/A Instrument Failure Mode:
N/A, need ?. 2 inputs for C00D Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
DkY Unique System Desc.:
-Suppression pool IcVel input points default to actual values when inputs exceed signal ranges.
NUREC 1394, Rev. 1 C-4 a_-
_. - -. -, _ _ - -, _. - ~. -. -
Page 104 DATA POINT LIllRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
H2 CONC Point ID:
CACX1200 Plant Spec Point Desc.:
PC 112 CONC Ceneric/Cond Dese.:
Drywell or Torus flydregen Concentration Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
Line4r (112 concent ration)
Hlnimum Instr Range:
0.000E+00 Haximum Instr Range:
0.300E402 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
2 (llydrogen concentration inputs) liow Processed:
Max. corrected reading w/ valve line up Sensor Locations:
Detectors @ RB 20' el.
Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A I
Instrument Failure Mode:
N/A Temperature compensation For DP Transmitters:
N/A Level Reference Leg:
N/A
' Unique System Desc.-
Processing includes the application of correction factors and compensates for temperature and pressure.
H2 conc. inputs default to actual values when inputs exceed signal ranges, 112 sample lines run to DW 100', 50' & 6'; Torus l'e1.
NUREG 1394, Rev. 1 C4
~.
~..
. ~..
i Page 105 DATA POINT LIl311 Ally llEFEllENCE FILE Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
02 CONC Point ID:
CACX1210 Plant Spec Point Desc.:
PC 02 CONC Ceneric/Cond Desc.:
Drywell or Torus Oxygen Concentration Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
Linear (02 concentration)
Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.2$0E+02 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
2 (Oxygen concentration inputs) llow Processed:
Max. corrected reading w/ valve line up Sensor Locations:
Detectors @ RB 20' el.
Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level N/A HI Detector Power Supply Turn on Power Level:
N/A Instrun.ent Failure Mode:
N/A Temperature Compensation
_'/ A For DP Transmitters:
h l
Level Reference Leg:
N/A 1
Unique System Desc.:
Processing includes the application of correction :.ctors and compensates for temperature and pressure.
02 conc. inputs default to actual values when inputs L
exceed signal ranges. 02 sample lines run r
l to DW 100', 50' & 6': Jorus l'e1.
NUREC 1394, Rev. 1 C4
-.. ~
Page 106 DATA POINT LIllilARY llEFERENCE FILE Date:
05/15/92 1...
Reactor Unit:
EK2 Data reeder:
N/A NRC ERDS Parameter:
CST LEVEL Point ID:
C0_LA005 Plant Spec Point Desc.:
CONDENSATE STORACE TANK LEVEL Ceneric/Cond Desc.:
Condensate storage Tank Level Analog / Digital:
A Engr Units / Dig States:
FTDEC Engr Units Conversion:
Linear (CST level): Ift= 15625 Callons Minimum Instr Idage:
0.000E+00 Haximum Instr Rance:
0.320E+02 Zero Point
Reference:
TNKBOT Reference Point Notes:
Tank bottom is 20' above mean sea level.
PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CST tank Alarm / Trip Set Points:
LOW = 0.120E+02 NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW /ilICll Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
DRY Unique System Desc.:
CST tank level points defaults to actual value when input exceeds signal range.
E5chunit's 500,000 gallons capacity tank can be cross connected to the other unit.
A standpipe reserves 100,000 gallons for use by 11P01 and RCIC.
l-NUREC+1304, Rev. 1 C4 l
- -. -.-..~-_
~ _
Page 107 I
DATA POINT LIBRARY REFERENCE FILE i
Date:
05/15/92 Re:c: or Unit:
BK2
. Data Feeder:
N/A NRC ERDS Parameter:
WIND SPEED Point ID:
WE_MA001 Plant Spec Pcint Dese.:
UPPER WIND SPEED Generic /Cond Denc.:
Wind-Speed at the Reactor Site Analog / Digital:
A Engr Units / Dig States:
MPil Engr Units Conversion:
Telemetry from Meteorological Tower Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.100E+03 Zeno Point
Reference:
N/A Reference Point Notes:
N/A
-PROC or SENS:
S Number of Sensors:
1 llow Processed:
N/A Sensor Locationst Het Tower at 104.6 meters above base, t
Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A 1
i Level Reference Leg:
N/A Unique System Dese.:
i l
The Met tower base is located 1400' NE of reactor complex & 20' above mean sea level NUREGd394,.Rav. 1.
C-4
_]
E Page 108 DATA POINT LIDII Ally llEFEllENCE FILE Date:
05/15/92 Reactor Unit:
BR2 Data Feeder:
N/A NRC ERDS Parameter:
WIND SPEED Point ID:
WE_MA006 Plant Spec Point Desc :
L74ER WIND SPEED Ceneric/Cond Desc.:
Wind Speed at the Reactor Site Analog / Digital:
A Engr Units / Dig States:
MPil Engr Unita Conversion:
Telemetry from Meteorological Tower Minimum Instr Range:
0.000E400 Maximum Instr Range:
0.100E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 llow Processed:
N/A Sensor Locations:
Het Tower at 11.5 meters above base.
Alarm / Trip Set Points:
N/A NI Detector Powes Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N //.
Instrument Failure Mode:
N/A Temperature Compensation Fo:
' Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
The Met tower base is located 1400' NE of reactor complex & 20' above mean sea level NUREG-1394, Rev. 1 C-4
DATA POIliT LIBit AltY ItEFEllE11CE FILE Date:
05/15/92 Reactor Unit:
EK2 Data Feeder:
N/A NRC ERDS Parametor:
WIND DIR Point ID:
WE_MA003 Plant Spec Point Desc.:
UPPER WIND DIRECTION Generic /Cond Desc.:
Wind Direction at the Reactor Site Analog / Digital:
A Engr Units.4.g States:
DEGFR Engr Units Conversion:
Telemetry from Meteorological Tower Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.360E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 Ilow Processed:
N/A Sensor Locations:
Met Tower at 104.6 meter above base.
Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Dese.:
the Met tower b.se 'ts located 1400' NE of c or comp 1 m & 20' above mean sea level 2
NUREC-1194, Rev. 1 C4
Page 110 DATA POINT LIllR ARY llEFERENCE F7 Date:
05/15/92 Reactor Unit:
BK2 Data Feeder:
N/A NRC ERDS Parameter:
WIND Dik Point ID:
WE_MA004 Plant Spec Point Desc.-
LOWER WIND DIRECTION Generic /Cond Desc.;
Wind Direction at the Reactor Site Analog / Digital:
A i
Engr Units / Dig States:
DECPR Engr Units Conversion:
Telemet ry f ron$ Meteorological Tower Minimum Instr Range:
0.000E+00 Maximum Instr Range:
0.360E+03 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 llow Processed:
N/A Sensor Locationst Met Tower at 11.5 meters above base.
Alarm / Trip Set Points:
N/A NI Detector Power Supply
~
Cut nff Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation For DP Transmitters:
N/A Level Reference Leg:
N/A Unique System Desc.:
The het tower base is located 1400' NE of rear. tor complex & 20' above mean sea level NUREG-1394, Rev. 1 C4
Page 111 DATA POINT LIllRARY REFERENCE FILE Date:
05/15/92 Reactor Unit:
EK2 Data Feeder:
N/A NRC ERDS Parameter:
STAB CLASS Point ID:
WE_MC001 Plant Spec Point Desc.*
NUMERIC PASQUILL STABILITY CLASS Generic /Cond Desc.:
Air Stability at the Reactor Site Analog / Digital:
A Engr Units / Dig States:
STABI Engr Units Conversion:
Telemetry from Netcorological Tower Minimum Instr Range:
0.000E+00 i
Maximum Instr Range:
0.700E+01 Zero Point
Reference:
COMPLX Reference Point Notes:
Zero means dTemp average was out of ranBe.
PROC or SENS:
P Number of Sensors:
2 Ilow Processed; h'eighted average of 2 Met Tower inputs Sensor Locations:
Met Tower @ 10.2 and 103.2 above base Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N.'A Instrument Failure Mode:
h/A, need 2 2 inputs.for C00D Temperature Compensation For DP Transmitters:-
N/A Level Reference Leg:
N/A Unique System Dese.:
The two differential temperature inputs are equally weighted in the average.
The dTemp range is -5 to +10 DEG C/100M.
The Met tower base is located 1400' NE of reactor complex & 20' above mean sea level NUREG 1394, Rev. 1 C4 l
,