ML20085L532
| ML20085L532 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 10/24/1991 |
| From: | Russell J POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK |
| To: | Taylor J NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO) |
| References | |
| RTR-NUREG-1394 IP3-NRC-91-063, IP3-NRC-91-63, NUDOCS 9111040208 | |
| Download: ML20085L532 (12) | |
Text
m
, _ _..... ~ _
- Indian Point 3 Nuctste Pown Plant PO. 004 215 Buchanan, New York 10$11
. 914 730.8001 4 NewYorkPower CMl!!,"
ter Authority October 24, 1991 IP3-NRC-91-063
. License No. 50-286 Docket No. DPR-64 Mr. James M. Taylor Executive Director for Operations II.S. Nuclear-Regulatory Commission Mail Station F1-137 Washington, D.C.
20555 Attn:
Document Control Desk
Subject:
Indian Point 3 Nuclear Power Plant Emergency Response Data System -
Implementation Plah
Dear Mr. Taylor:
In accordance with 10 CFR 50 Appendix E, this letter provides the Authority's Emergency Response Data System (ERDS) Implementation Plan for the Indian Point Unit 3 Nuclear Power Plant.
The attachments provide information
-requested by NUREG-1394, Rev. 1:
I.
Completed Appendix B II.
Emergency Plan procedures needing development or revisions III.
Implementation Plan If you have any ucations, please contact Mr. Bryan-J. Ray at 914-736-80437 j
/
V6ry - rulycyoursj
/_ %
g Joseph
.~ Russell Resident Manager Indian Point 3 Nuclear Power Plant JER:bjr:rj Attachments-e 911to4o20s 9t1024 i
v
-PDR ADOCK 05000286 j
p POR
'I cct U.S. Nuclear Regulatory Commission 475 Allendale Road
' King of Prunnia, PA 19406 IP3 Ronident Inspector Indian Point 3 U.S. Nuclear Regulatory Commission P.O. Box 337 Buchanan, New York 10511 Nicola F. Conicella, Project Manager Project Directorato I-1 Divinion of Reactor Projects - I/II U.S. Nuclear Regulatory Conimission Mall _Stop 14B2 Washington, D.C.
20555
-ATTACHMENT 1 o
6 APPENDIX B L
ERDS COMMUNICATIONS DESCRIPTION AND SURVEY QUESTIONNAIRE li f.:
f.
)-
l l
l
ATTACHMENT 1 l
}
- 1. Contacts Note: Please provide name. title. mailing address. and phone number.
A.
Survey Coordinator (i.e.. contact for later clarificauon of questionnaire answers):
Anthony Cerwin, Computer Services Manager 914-736-8732 P.O. Box 215 Indian Point 3 Station Buchanan, N.Y.
10511 B.
Co.nputer Hardware Specialist (s):
James Davis, Computer Services Hardware Supervisor 914-736-8710 P.O. Box 215 Indian Point 3 Station Buct,anan, N.Y.
10511 C.
Systems Software Specialist (s):
Roger Harris, Computer Services Application Supervisor 914-736-8712
{
P.O. 5x 215-Ir.dian Point 3 Station Buchanan, N,Y.
10511 l
D.
Application. level Software Specialist (s);.
Roger Harris Computer Services Application Supervisor 914-736-8712 P.O. Boy 215 j
Indian Foint 3 Station Buchanan, N.Y.
10511 l
E.
Telephone Systems Specialist (s):
David Daley, Supervisor 914-736-8708 P.O. Box 215 I
Indian Point 3 Station Buchanan, N.Y.
10511 l
NUREG-1394. Rev.1 B-2 61 1
ATTACHMENT 1 1
111. Selection Of Data Feeders A.
How many data feeders are there (six maximum)?
One (1)
B.
Identify the selected data feeders and provide the following for each:
(1) a short description of the categories of data points it will provide (e.g., met. rad, or plant data points, by unit) and (2) the rationale for selecting it if another system can also provide its categories of data points.
All available points are in the plant computer except Meteorological parameters t
C. Which data feeder is the site time determining feeder? This should be the feeder which is providing the majority ot' the data points.
l N/A 1
B-7
.l NUREG-1394. Rev.1 I
ATTACHMENT-1 IV. Data Feeder Information Note: A new Section IV must be filled out for each feeder system selected.
General Questions 1.
Identification of Data Feeder What is the name in 1001 parlance given to this data feeder (e.g., Emergency Res a.
Information System)? Please give both the acronym and the words forming it.
CFMS = Critical function Monitoring System b.
Is this the site time determining feeder?
YES How often will this feeder transmit an update set to the ERDS (in seconds)?
c.
15 seconds 2.
Hardware / Software Ernironment Identify the manufacturer and model number of the data feeder hardware.
a.
Perkin-Elmer (Concurrent Computers) 3200 series b.
Identity the operating system.
OS/32 What method of timekeeping is implemented on this feeder system (Daylight Savines.
c.
Standard. Greenwich)?
~
ESTj0ST J.
In unat time zone ;s Inis feeder located?
EST NUREG-1394. Rev. I B-6 i
]
ATTACHMENT 1 I
1 Data Communication Details d
Can this data teeder provide asynchtnnous seriai data communication t flS-32 C) a.
with tull modem control?
YES b.
Will this feeder transmit in ASCII or EBCDIC?
ASC11 Can this feeder transmit at a serial baud rate of 2400 bps? If not. at what baud rate can c.
it transmit?
YES d.
Does the operating system support XON/XOFF flow control?
YES i
1.
Are any problems foreseen with the NRC using XON/XOFF to control the trans.
mission of data?
i l
NO If it is not feasible to recontigure a serial port for the ERDS linkup (i.e.. change the e.
baua rate. parity, etc.) please explain why.
N/A Do any ports currently exist for the ERDS linkup?
f.
YES i
l.
If not. is it possible to add additional ports?
N/A D-9 NUREG-D94. Rev.1
4 All ADIMEN1 1 11 yes. will ihe port be used solely t3y the ERDS or shared with other non.
emergency hme users! Give details.
Exclusively [RD5 4
Data Teeder Physical Ensironment and Management Where is the data feeder located in terms of the TSC. EOF, and control room?
a.
1SC b.
Is the de'a feeder protected from loss of supply of electricity?
YES - via UPS c,
is there a human operator for this data feeder?
YES 1.
If so. how many hours a day is the feeder attended?
I shift / 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> NUREG-1394. Itev. I D-10
1 ATTACHMENT 2 EMRflGENC1.PJ ARANDJMELEMENIINQ_ERQQEDVBELQliANGES REQ VIRE D_ID_EN S UR ELE B p_SEILVAIl0N_AN D_IE SIlNQ The following Emergency Plan implomonting Proceduros will be writton/ revised to incorporato reference to and instruction for activation and testing of ERDS:
.Emcrgency_PJp1LXohmeJL _ Empr00ncy.ROSponE0AQ1!VMQM The " Control Room" ano/nr " Technical Support Center" (TSC) sections, as deterrnined appropriato, will be revised to assign responsibility for activation of ERDS by either Control Room or TSC personnd. Those sections will also be revised as appropriato to ensure voice transmission of data not available via ERDS.
EMRL0 encyJ?ta!hlohimejil - Imp!cmoiltla9f racadu!.es; 1,
implomonting Proceduro IP-1085 " Maintenance of Emor00ncy Preparedness at iP3", will bG revised to indicato the requiromont for quarterly testin0 of ERDS.
2.
A new Emergency Plan ImplementinD Procedure will be written to describo ERDS and provide critoria and instruction for activation and testing of ERDS.
ATTACHMENT 3
_EnleI90D0Y_fl9SD00sq DatAjyS1001(El]DS)jmp!0Montallonflan lot jndian EqLnt a NucionLEoweLElant Rotorenc0g 1.
10CFR 50.72 (a) (4) Immodiato notification requirements for operating nuclear power reactors.
2.
Appendix E to Part 50 - Emergency Planning and Preparodness for Production and Utilization Facilities, VI, Emergency Response Data System.
3.
NUREG - 1394, Rev.1, Emergency Responso Data System (ERDS) i implementation.
The implementation plan for the Emergency Responso Data System (ERDS) at the Indian Point 3 Nuclear Power Plant (IP3), consists of two (2) major tasks:
1.
Initial installation and establishment of the system.
2.
Establishment of the administrative controls for operation and maintenance of the system.
Sub-tasks required to be completed in order to accomplish these two (2) major tasks have been id0ntified and are delineated as follows including the responsiblo IP3 group and the expected completion dates:
A.
Ins _tallatl00_nn dJs t a t;1[s bmealoit belystem; 1.
Establish contact with the NbS Corporation, El Division (NUS-EI) for interfacing and site visit Relponsible Group:
Computer Services, Licensing, Emergency Plannin0 Completed 10/16/91 l
2.
Con plete NUREG-1394, Rev.1, Appendix B.
Responsible Group:
Computer Services Completed 10/23/91; (Attachment 1) 3.
Determine iim a available Point identification Descriptions (PIDs).
(
Responsible Group:
Computer Services Completion Date:
10/15/91 4.
Establish IP3 PIDs and ensure plant review / concurrence.
Responsible Group:
Licensing l
Completion Date:
10/31/91
ATTACilMENT 3 S.
Dotormino the location for onsito activation of the ERDS.
Responsiblo Group:
Emor00ncy Planning Completion Dato:
11/08/91 6.
Review NUREG - 1394, Rev.1 and IP3 computer capahikty.
Rosponsib!o Group:
Computer Services Completion Dato:
11/28/91 7.
Initiato purchaso requisition for provision of required hardwaro and software.
Responsibio Group:
Computer Services
{
Completion Dato:
11/28/91 8.
Award contract for installation of hardware and software Responsible Group:
Computer Services Completion Dato:
03/31/92 9.
Coordinato NRC's installation of the modum, Responsiblo Group:
Computer Services Completion Dato:
OG/01/02 10.
Provido and install software.
Rosponsiblo Group:
Computer Servicos/IP3 Contractor Completion Dato:
06/01/92 11.
Writo and perform prohminary system test.
Responsiblo Group:
Computer Services /IP3 Contractor Completion Dato:
0G/01/92 12.
Complete Data Point Library (DPL) including unique system description.
Responsibio Group:
Technical Services Completion Dato:
08/31/92 13.
Writo quarterly performar.co test.
Responsibio Group:
Computer Servicos/IP3 Contractor Completion Dato:
07/31/92 14.
Conduct formal / final acceptanco tost.
Responsible Group:
Computer Services /IP3 Contractor Completion Dato:
09/30/92
4 ATTACHMENT 3 B.
AdmipJtit ra tly.q_Qontr olttf oLQp ot M!oita nd_M ainto n e!1c o-.olt hof>y st em; 1,
Identify Emergoney Plan proceduros needed or requirin0 ravision.
Responsible Group:
Emor00ncy Planning Completion Date:
10/28/91 (Attachment 2) 2.
Writo or reviso proceduro to ensure that hardware and software chan005 that could affect transmission format and computer communication protocol are provided to the NRC prior to change.
Responsibio Group:
Computer Services / Licensing Completion Date:
08/31/92 3.
Ensure that any changes to the DPL are submitted to the NRC within 30 days after the changes are mado.
Responsiblo Group; Nuclear En0ineering (Corporato Office)/
Licensing Comp 4 tion Dato:
08/31/92 4.
Writo and reviso Emer0cncy Plan Implomonting Procedures to includo directivos for periodic testing; activation of ERDS; and voice transmittal of data not available via ERDS.
Responsiblo Group:
Emer00ncy Planning Completion Date:
08/30/92 5.
Conduct training for those responsiblo for activation and monitorinD Of ERDS, and those who may L;c responsible for voice transmittal of data not available.
Responsiblo Group:
Training Completion Dato:
09/30/92 6.
Initiato quarterly testing of ERDS.
Responsiblo Group:
Emergency Planning Completion Dato:
1st quarter after 09/30/92 7.
Provide for maintenance of ERDS Responsible Group:
Computer Services Completion Date:
09/30/02
_ _ _ _ _ _ _ _