ML20083L240
| ML20083L240 | |
| Person / Time | |
|---|---|
| Site: | Diablo Canyon |
| Issue date: | 04/11/1984 |
| From: | Schuyler J PACIFIC GAS & ELECTRIC CO. |
| To: | Martin J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| References | |
| DCL-84-140, NUDOCS 8404170189 | |
| Download: ML20083L240 (8) | |
Text
.
' %6 RELATED CORRESPONDENCE J
BSCKETED USNRC PACIFIC GAS AND ELECTR.IC C OM PANY 7ME A$$5dtS3$7rR ANCISCO, CAUFORNu 9406 T E M P t* D N E W 5 ) 781.U U g g
@C# OI SECRt.?ADY
.<. ?'. ' I tt E n".'l. -
April 11, 1984 PGandE Letter No.:
DCL-84-140 Mr. John B. Martin, Regional Administrator U. S. Nuclear Regulatory Commission, Region V 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596-5368 Re:
Docket No. 50-275, OL-DPR-76 Docket No. 50-323 Diablo Canyon Units 1 and 2 Revision to IEIR 83-37 and 83-25 -- Notice of Violation
Dear Mr. Martin:
NRC Inspection Report 50-275/83-37 and 50-323/83-25, dated February 29, 1984, 4
included a notice for a Severity Level IV violation. PGandE responded to this notice on March 29, 1984 (PGandE Letter No. DCL-84-124). This response supercedes, in its entirety, the March 29, 1984 submittal.
Kindly acknowledge receipt of this esterial on the enclosed copy of this letter and return it in the enclosed addressed envelope.
l Sincerely, W. A. Raymond for J. O. Schuyler Enclosure cc: Service List 8404170189 840411 PDR ADOCK 05000275 l
G PM l
PGandE Letter No.: DCL-84-140 ENCLOSURE RESPONSE TO NOTICE OF VIOLATION IN NRC INSPECTIQ REPORT NOS. 50-275/83-37 AND 50-323/83-25 On February 29, 1984 NRC Region V issued a Severity Level IV Notice of Violation (" Notice") as part of NRC Inspection Report Nos. 50-275/83-37 and 50-323/83-25 on Diablo Canyon Units 1 and 2.
The " Notice" cited:
e Twenty-eight Pullman employees began inspecting and accepting weldments prior to completion of required training and certification as welding inspectors.
DEFICIENCIES IN THE TRAINING AND CERTIFICATION OF PULLMAN WELDING INSPECTORS STATEMENT OF VIOLATION "As a result of the inspection conducted on November 14-18 and Noved er 28 -
Deced er 9, 1983, and in accordance with NRC Enforcement Policy 10 CFR Part 2, Appendix C, the following violation was identified:
Section 17.1.5 of the FSAR (dated October 1978) and the Pacific Gas and Electric Company Quality Assurance Manual Section V (dated August 15,1978) states, in part, that, " Activities affecting quality shall be prescribed by documented instructions, procedures, or drawings...and shall be accomplished in accordance with these instructions, procedures, or drawings...."
Engineering Standard Diablo (ESD) No. 237, " Quality Assurance Inspector Training Program," dated February 26, 1974, states in paragraph 2.3 that, "All personnel engaged as Field QA Inspectors involved in the inspection of weldsents, interpretation of Engineering Specifications and Welding Procedures, and documentation work, shall be required to complete an indoctrination period as described in Section 4 of this specification."
Paragraph 4.1 states that, "The indoctrination period for the Field Q.A.
Inspectors described in Section 2.3 shall contain as a minimum, but not necessarily limited to, the following courses:
Visual Inspection Welding Procedures Weldin Inspection Welding Processes Basic
.A.
Other courses offered as optional are:
Welding Steam Power Plant Fundamentals Basic Power Plan Instruction Welding)& Piping Engineer. Technology (I.C.S.
Introducing Nuclear Power 0778d/0009K.
.o The Visual Inspection and Welding Inspection tests shall be administered and l-controlled by the N.D.E. Training Officer. All N.D.T. training, qualifications and certifications will be covered by ESD-235."
Paragraph 4.2 states that, " Tests used for the indoctrination courses for Field Q.A. Inspectors shall be:
l 1.
For Basic Q.A. Test-ESD's.
2.
For Weld Procedure Test-Approved Welding Procedures.
3.
For the Weld Process Test, Welder Qualification Card and Pipefitter's l
Manual.
4.
For Welding Inspection Qualifications, General Welding Information.
5.
Visual Inspection Qualifications-General Dynamics NDT Introduction."
A Nuclear Services Corporation (NSC) Audit dated October 27, 1977, identified in Criterion IX, Finding No. 3 (of the audit) twenty-eight individuals which were alleged to have begun performing their duties without fulfilling the Pullman Power Products procedural requirements for certification and qualification of Quality Assurance (Welding) Inspectors.
Contrary to the abo've requirements of the FSAR and Pullman procedures, the inspector identified on November 15, 1983 that in virtually all cases the individuals hired after September 25, 1973, named in the NSC audit finding (who were assigned to perform welding inspections), began inspecting and accepting weldments, before completing the required training, taking the required examinations, and before being certified as a welding inspector.
It j
is noted that the Pullman Power Products response to this Nuclear Services Corporation finding states, in part that, "All current inspectors have been i
qualified by test as outlined in ESD-237. The requirement for qualification and certification of field inspector were added in ESD-237 on September 25, 1973 to reflect the requirements of ANSI N45.2.6, just published. Persons hired before this time were not necessarily tested at time of hire.
j Subsequent to 1973, the records indicate that all inspection personnel received required training and examination." However, the Pullman response is silent with regards to inspectors performing inspectices prior to certification.
This.is a Severity Level IV Violation (Supplement II)."
l EXPLANATION AND CORRECTIVE STEPS TAKEN The following discusses the corrective measures being taken in response to the issues raised by this Notice. Briefly, we will (1) provide background information concerning Pullman's approach 'to welder inspector training and qualification; (2) explain the corrective steps taken to address the issue of inspector qualification identified in the NSC audit meeting including the scope of the reinspection program; and (3) identify any rework of those welds 1
that require modification.
Prior to January 1973, no requirement or guidance existed within the industry directing the documentation, qualification, or certification of inspectors.
First guidance to industry appeared in ANSI M45.2.6 Standard issued on January 25, 1973. This guidance was subsequently incorporated in NRC Regulatory Guide 1.58. Review of the M. W. Kellogg (* Pullman")
0778d/0009K - - -
3 l
inter-office correspondence indicates that as of June 14, 1973, they had determined that a documented training program was desirable. The development i
of this program began in September 1973 and the program as described in ESD 237 was approved by PGandE on February 6,1974.
In PGandE's investigations, 17 of the 28 individuals cited by the NSC Audit were welding inspectors. The other eleven were non-destructive test inspectors who were fully qualified to perform ND Testing prior to beginning those activities. Pullman Welding Inspectors have been placed into three categories according to their time of hire:
A.
Four individuals were hired to perform weld inspections from the start of work through August 1973. All inspectors were qualified to perform visual weld inspections based on a review of documentation of previous work experience and education.
the period from The files of all inspectors hired during'980 were reviewed. Fifty-three B.
September 1, 1973 through December 31, inspectors were hired between September 1, 1973 and October 3, 1975. Of these, seventeen inspectors performed inspections prior to completion of the training and testing requirements of ESD-237. After October 3, 1975, all individuals were qualified to ESD-237 requirements before performing inspections.
C.
One hundred and seven individuals were hired to perform weld inspections from January 1, 1981 to the present. The records of twenty-three of these individuals were reviewed. All years (between 1981 and 1984) were included in this sample. Twenty-one were qualified in accordance with ESD-237 requirements prior to becoming inspectors. The remaining two became inspectors one day prior to documentation being placed in their records. This is considered an administrative delay.
These results provide confidence that the requirements of ESD-237 have been fully implemented from October 3, 1975 to date.
Based on documentation of previous work experience and education, all except two individuals who performed inspections prior to documentation of qualification were knowledgeable in welding inspection. We consider these individuals provisionally qualified to perform inspections unless proven otherwise during the reinspection program. Messrs. Guy and Cubbage were not considered qualified to perform inspections, based on past experience.
For the 15 inspectors who are provisionally qualified, a sampling of 20% or more of accessible welds inspected prior to compliance with the ESD-237 procedure is being reinspected. The reinspection is limited to accessible welds only. Accessible welds are defined as not being inside concrete, within sleeves, penetrations, or on heat traced lines.
If more than one percent of the welds reinspected for any individual is rejected, the reinspection program will continue until a rejection rate of 15 or less is achieved, or 100% of the accessible welds inspected by this individual have been reinspected.
0778d/0009K _
For Messrs. Guy and Cubbage, all accessible welds inspected prior to qualification are being reinspected.
These welds were originally inspected to B31.1 and B31.7 requirements. At that time, the codes required a minimum socket weld size of 1.25xt (t= nominal piping wall) but not less than 1/8 of an inch. The welds were measured with a variety of methods, including visual inspection, straight edge rules, handmade weld gauges, or Palmgren Gauges designed for measuring 900 structural steel fillet welds.
Inspectors used interpolation of the scale markings while rotating the scale around the socket weld.
The reinspection program is being performed in accordance with B31.1 (1967) including the Summer 1974 Addendum, B31.7 (1969) and ASME Section III which requires a minimum socket weld size of 1.09xt (t= nominal piping wall). The reinspection uses Fibremetal weld gauges which are more accurate than previous methods.
Attachments A and B summarize the inspection scope and results to date.
During the reinspection program,1059 welds have been reinspected.
Fifty-seven are suspect.
The suspect welds are, in general, on small bore piping. Ninety-five percent are socket welds connecting adjacent piping spools. Two are butt welds connecting 4-inch to 6-inch pipe. The remainder connect stanchions or lugs to the pipe.
Suspect welds found by welding inspectors will be reinspected by supervisory level welding inspectors.
If the suspect condition is verified by the supervisors, the weld will be rejected and referred to Engineering.
Engineering will either accept the welds based on analysis or the welds will be repaired.
A high level of confidence in the quality of work being reinspected is established by:
1.
All Code Class A and B, and pressure retaining Code Class C welds were inspected using NDE methods by qualified individuals in addition to the visual inspections.
2.
In some cases, the welding inspection was witnessed by the Authorized Nuclear Inspector.
3.
All Design Class 1 piping has been hydro-tested and, in some cases, reinspected for the base line data as a part of the Inservice Inspection Program.
CORRECTIVE STEPS WHICH WILL BE TAKEN Weldinents are being re-inspected for acceptability by qualified inspectors in accordance with the above discussion.
Should any of these welds be unacceptable, they will be repaired in accordance with the existing approved procedures or the basis for acceptance will be established.
0778d/0009K i
i DATE WHEN FULL COMPLIANCE WILL BE ACHIEVED Full compliance with procedure ESD-237 has been in effect since October 3, 1975.
PGandE plans to complete all corrective action within 30 days for Unit 1, and 60 days for Unit 2 of the date on this submittal. A final report detailing the results of all inspection activities and the disposition of suspect welds will be submitted for Unit 1 and Unit 2 after completion of all corrective l
action.
1 l
l l
l l
l l
l l
0778d/0009K PGandE Lettcr No.:
DCL-84-140 Attachment A REINSPECTION PROGRAM FOR PROVISIONALLY QUALIFIED IN5PECTORS(l)
Minimum Inspections (2) Reinspected (3)No. Already(4) Suspect (5)
No. of No. to be Reinspected Name Allmendinger 69 14 31 1
Bloom 2
2 2
0 Bowlby 387 78 117 7
Boyd 192 39 51 1
Finch 289 58 114 4
Jennings 423 85 4
Kaz 3
3 1
0 Kincade 84 17 23 2
Page 149 30 42 2
Pennie 29 4 59 81 2
0'Brien 2
2 2
0 Sarvwatari 313 63 72 1
i Silver 47 10 11 0
Thomas 17 10 10 0
Willard 367 74 135 16 2638 544 788 40 NOTES 1.
These results have been revised and updated from the March 23, 1984 (DCL-84-115) and March 29, 1984 (DCL-84-124) submittals and are correct as of April 10, 1984.
2.
No. of inspections - Number of weld inspections prior to meeting the requirements of ESD-237.
3.
No. to be reinspected - 20% or more of accessible welds which are being reinspected.
4.
No. already reinspected - progress of program to date.
5.
Suspect - Welds which have been referred to Supervision for review against code tolerances.
0778d/0009K
O e
PGandE Letter No.: DCL-84-140 Attachment B REINSPECTION PROGRAM FOR(I)
UNQUALIFIED INSPECTOR 5 Minimum No. of No. to be Inspections (2) Reinspected (3)No. Already(4) Suspect (5)
Name Reinspected Guy 300 300 260 16 Cubbage 23 12 11 1
323 312 271 17 NOTES 1.
These results have been revised and updated from the March 23, 1984 (DCL-84-115) and March 29,1984 (DCL-84-124) submittals and are correct as of April 10, 1984.
2.
No. of Inspections - Number of weld inpsections prior to meeting the requirements of ESD-237.
3.
No. to be reinspected - All of accessible welds which are being reinspected.
4.
No. already reinspected - Progress of program to date.
5.
Suspect - Welds which have been referred to Supervision against Code tolerances.
0779d/0009K
._