w ll l
Duke Ibuer Company (704)675 4000 i
b!cGuire Nuclear Station i
12700llagm Terry Road
, Huntmnlir, ?C28078-6955 DUKEPOWER October 4,1993 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555 i
Subject:
McGuire Nuclear Station Docket No. 50-369 l
Unit 1 Steam Generator Outage August 1993 Pursuant to McGuire Technical Specification 4.4.5.5a the following information is submitted for the McGuire Unit 1 Steam Generator Outage in August 1993. The following quantities of tubes were removed from service or repaired:
Steam Generator No. of Tubes Plugg_ed_
No. of Tubes Repaired A
44 0
B 23 0
C 22 0
D 39 0
Questions or problems should be directed to Kay Crane, Regulatory Compliance at (704) 875-4306.