,'o, UNITED STATES y \\, y yqf(,g NUCLEAR REGULATORY COMMISSION
)
/
p WASW NGTON, D. C. 20555 s, ~ f KANSAS STATE UNIVERSITY DOCKET NO. 50-188 AMENDMENT TO FACILITY OPEI'ATING LICENSE Amendment No. 8 License No. R-88 1.
The U.S. Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment to Facility Operating License No. R-88, filed by the Kansas State University (the licensee), dated July 14, 1993, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's reies and regulations as set forth in 10 CFR Chapter I:
B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance:
(i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied; and F.
Prior notice of this amendment was not required by 10 CFR 2.105(a)(4)-
and publication of notice for this amendment is not required by 10 CFR 2.106(a)(2).
9309110227 930720 PDR ADOCK 05000188 P
t 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the enclosure to this license amendment, and paragraph 3.B of Facility Operating License No. R-88 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised 4
through Amendment No. 8, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION Seymour H. Weiss, Director Non-Power Reactors and Decommissioning Project Directorate Division of Operating Reactor Support Office of Nuclear Reactor Regulation j
Enclosure:
Appendix A Technical Specifications Changes Date of Issuance:
July 20, 1993 1
1
ENCLOSURE TO LICENSE AMENDMENT NO. 8 FACILITY OPERATING LICENSE NO. R-88 DOCKET NO. 50-188 Replace the following page of the Appendix A Technical Specifications with the enclosed page. The revised page is identified by amendment number and the change is indicated by a vertical line.
Remove Insert 9
9 l
l l
TABLE I - MINIMUM REACTOR SAFETY SYSTEM SCRAMS Originating Set Point Mode in Which Channel Effective SS Pulse 1.
Linear 110% of full power X
2.
Safety 110% of full power X
3.
Scram Bar on Console Manual X
X X
X 4.
Ion Chamber Power. Supply ~
Failure 5.
Fuel Temperature 450 C X
TABLE II - MINIMUM INTERLOCKS Action Prevented Mode in Which Effective SS Pulse 1.
Shim and regulating rod withdrawal with less X
than two neutron induced counts per second on the start-up channel.
2.
Simultaneous manual withdrawal of two rods.
X 3.
Application of air to transient rod unless the x
transient rod shock absorber is in the fully down position.
4.
Movement of any rod except transient rod.
X j
- May be defeated during fuel loading in'accordance with fuel loading procedure.
Amendment No. 8
}