Text

.-

aa

.g' W

MODEL TEClINICAL SPECIFICATION 4.3.B.1 DRESDEN STATION UNIT NO. 1

~

"453.B Control' Rods 1.

The coupling integrity. shall be verified for each control rod following refueling outage or for, specifically affected control rods-following maintenance on or codification to,the-control rod or rod drive system'which could affect the rod drive ' coupling.

integrity by:

a.

Performing a rod pull test with the head removed from the 1

reactor vessel. The rod pull test shall consist.of with-

~

drawing the rod one notch then pulling the red to the fully -

inserted position.

The red shall be considered coupled if the lif ting force required to return the rod to the fully-inserted position is greater than (

) lbs. but less then

(

) lbs.

j i

b.

Observing discernible response of the nuclear instru=enta-i tion sft:en the rod is withdrawn.

For rods withdrawn early in startup when response is not discernible, subsequent exercising of these rods af ter the reactor-is critical shall.

1 be performed to verify instrucentation' response."

{..