ML20035C554

From kanterella
Jump to navigation Jump to search
Attachment 1 - Targeted ITAAC Listing for Vogtle Electric Generating Plant Units 3 and 4
ML20035C554
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 02/04/2020
From: Christopher Welch
NRC/NRR/VPOB
To:
Christopher Welch
Shared Package
ML19329C875 List:
References
Download: ML20035C554 (38)


Text

Index No.

ITAAC No.

Reference ITAAC ITAAC Family Expert Panel Targeted ITAAC Activity Plant System License Amendment Change License Amendment Number V3/V4 Consolidated into ITAAC No.

VOICES CIPIMS Status Comment 1

2.1.01.01 13A Fuel Handling and Refueling System Deleted 170/168 2

2.1.01.02 13A Fuel Handling and Refueling System Deleted 113/112 4

3 2.1.01.03 R

11X Fuel Handling and Refueling System Deleted 85/84 4

2.1.01.04 13D Untargeted Fuel Handling and Refueling System Revised 113/112 5

2.1.01.05 13D Fuel Handling and Refueling System Deleted 113/112 4

6 2.1.01.06.i 13A Fuel Handling and Refueling System Deleted 113/112 4

7 2.1.01.06.ii 13E T

Fuel Handling and Refueling System T

8 2.1.01.07.i 13F Fuel Handling and Refueling System 9

2.1.01.07.ii 13A Fuel Handling and Refueling System Deleted 113/112 4

10 2.1.01.07.iii 13E Fuel Handling and Refueling System 11 2.1.01.07.iv 13F T

Fuel Handling and Refueling System Revised 23 T

12 2.1.02.01 14A T

Reactor Coolant System T

13 2.1.02.02a 06F T

Reactor Coolant System Revised 85/84 T

14 2.1.02.02b 03F T

Reactor Coolant System Deleted 85/84 13 15 2.1.02.03a 06B T

Reactor Coolant System Deleted 85/84 13 16 2.1.02.03b 03B T

Reactor Coolant System Deleted 85/84 13 17 2.1.02.04a 06C Reactor Coolant System Deleted 85/84 13 18 2.1.02.04b 03C Reactor Coolant System Deleted 85/84 13 19 2.1.02.05a.i 14A Reactor Coolant System Revised 85/84 T

VOGTLE UNIT 3 & 4 ITAAC The following spreadsheet shows all ITAAC for Vogtle Units 3 and 4. This represents the ITAAC from the AP-1000 DCD Rev. 19, the 56 site specific COL ITAAC and ITAAC changes from License Amendments 1 through 171 for Vogtle 3 and 1 through 169 for Vogtle 4. The "Targeted" ITAAC activities that compromise the baseline inspection program are those ITAAC activities identified as targeted (T) under the "Expert Panel Targeted ITAAC Activity" column.

ATTACHMENT 1 2/4/2020 Page 1 of 38

20 2.1.02.05a.ii 14E T

Reactor Coolant System Deleted 85/84 19 21 2.1.02.05a.iii 14F T

Reactor Coolant System Deleted 85/84 19 22 2.1.02.05b 04F T

Reactor Coolant System Deleted 85/84 13 23 2.1.02.06 03F T

Reactor Coolant System Deleted 85/84 13 24 2.1.02.07a.i 10E T

Reactor Coolant System Deleted 85/84 19 25 2.1.02.07a.ii 09F T

Reactor Coolant System Deleted 85/84 19 26 2.1.02.07b 09A Untargeted Reactor Coolant System 27 2.1.02.07c R

09X Reactor Coolant System Deleted 85/84 28 2.1.02.08a.i 07A T

Reactor Coolant System T

29 2.1.02.08a.ii 07C T

Reactor Coolant System T

30 2.1.02.08b 06D T

Reactor Coolant System T

31 2.1.02.08c 06C Reactor Coolant System 32 2.1.02.08d.i 03D T

Reactor Coolant System T

33 2.1.02.08d.ii 03F T

Reactor Coolant System Revised 111/110 T

34 2.1.02.08d.iii 03A T

Reactor Coolant System Revised 62 T

35 2.1.02.08d.iv 07E T

Reactor Coolant System Revised 62 T

36 2.1.02.08d.v 07A T

Reactor Coolant System Revised 113/112 T

37 2.1.02.08d.vi 07A Reactor Coolant System Deleted 113/112 36 38 2.1.02.08d.vii 03A T

Reactor Coolant System T

39 2.1.02.08d.viii 03A T

Reactor Coolant System Deleted 113/112 36 40 2.1.02.08e 07F Reactor Coolant System Revised 114/113 41 2.1.02.09a 14D T

Reactor Coolant System T

42 2.1.02.09b.i 08D Reactor Coolant System 43 2.1.02.09b.ii 10D Reactor Coolant System Page 2 of 38

44 2.1.02.09c 08D Reactor Coolant System 45 2.1.02.10 10A Untargeted Reactor Coolant System Deleted 113/112 47 46 2.1.02.11a.i 10C T

Reactor Coolant System T

47 2.1.02.11a.ii 10C Untargeted Reactor Coolant System Revised 113/112 T

48 2.1.02.11b.i 10C T

Reactor Coolant System T

49 2.1.02.11b.ii 10C T

Reactor Coolant System Deleted 113/112 47 50 2.1.02.11b.iii 10D T

Reactor Coolant System Deleted 113/112 47 51 2.1.02.11c.i 10C Reactor Coolant System 52 2.1.02.11c.ii 10C Reactor Coolant System 53 2.1.02.12a.i 07E T

Reactor Coolant System Revised 85/84 T

54 2.1.02.12a.ii 07F T

Reactor Coolant System Deleted 85/84 53 55 2.1.02.12a.iii 07D T

Reactor Coolant System T

56 2.1.02.12a.iv 07E T

Reactor Coolant System Revised 85/84 T

57 2.1.02.12a.v 07F T

Reactor Coolant System Deleted 85/84 56 58 2.1.02.12a.vi R

03X Reactor Coolant System Deleted 85/84 59 2.1.02.12a.vii R

03X Reactor Coolant System Deleted 85/84 60 2.1.02.12a.viii R

03X Reactor Coolant System 61 2.1.02.12a.ix R

07X Reactor Coolant System 62 2.1.02.12b 07D Reactor Coolant System Deleted 113/112 47 63 2.1.02.13a 10D Reactor Coolant System 64 2.1.02.13b 10D T

Reactor Coolant System T

65 2.1.02.13c 10D Reactor Coolant System 66 2.1.02.14 10D Reactor Coolant System 67 2.1.02.15 10A Untargeted Reactor Coolant System Page 3 of 38

68 2.1.03.01 05A Untargeted Reactor System 69 2.1.03.02a 05A Untargeted Reactor System Revised 113/112 70 2.1.03.02b 05A Untargeted Reactor System Deleted 113/112 69 71 2.1.03.02c 05A T

Reactor System T

72 2.1.03.03 05F T

Reactor System Revised 85/84 T

73 2.1.03.04 05B T

Reactor System Deleted 85/84 72 74 2.1.03.05 05C T

Reactor System Deleted 85/84 72 75 2.1.03.06.i 05A Reactor System Revised 85/84 T

76 2.1.03.06.ii 05E T

Reactor System Deleted 85/84 75 77 2.1.03.06.iii 05F T

Reactor System Deleted 85/84 75 78 2.1.03.07.i 05D Deleted on Unit 3 & 4 Reactor System Deleted 113/112 151/150 T

79 2.1.03.07.ii 05D T

Reactor System Deleted 113/112 78 80 2.1.03.08 05A Reactor System 81 2.1.03.09a.i 09F T

Reactor System Deleted 85/84 75 82 2.1.03.09a.ii 10A T

Reactor System Deleted 85/84 75 83 2.1.03.09b 10C Untargeted Reactor System 84 2.1.03.09c R

09X Reactor System Deleted 85/84 85 2.1.03.10 05A Reactor System Deleted 113/112 78 86 2.1.03.11 05F T

Reactor System T

87 2.1.03.12 10A Reactor System 88 2.1.03.13 05F T

Reactor System T

89 2.1.03.14 05B Reactor System 90 2.2.01.01 11A T

Containment System T

91 2.2.01.02a 06F T

Containment System Revised 85/84 T

Page 4 of 38

92 2.2.01.02b 03F T

Containment System Deleted 85/84 91 93 2.2.01.03a 06B T

Containment System Deleted 85/84 91 94 2.2.01.03b 03B T

Containment System Deleted 85/84 91 95 2.2.01.04a.i 06C T

Containment System Deleted 85/84 91 96 2.2.01.04a.ii 06F T

Containment System T

97 2.2.01.04b 03C T

Containment System Deleted 85/84 91 98 2.2.01.05.i 11A Containment System Revised 85/84 T

99 2.2.01.05.ii 11E T

Containment System Deleted 85/84 98 100 2.2.01.05.iii 11F T

Containment System Deleted 85/84 98 101 2.2.01.06a.i 08E T

Containment System Deleted 85/84 98 102 2.2.01.06a.ii 09F T

Containment System Deleted 85/84 98 103 2.2.01.06b 09C Untargerted Containment System 104 2.2.01.06c R

09X Containment System Deleted 85/84 105 2.2.01.06d.i 08E T

Containment System Deleted 85/84 98 106 2.2.01.06d.ii 08F T

Containment System Deleted 85/84 98 107 2.2.01.07.i 11D T

Containment System T

108 2.2.01.07.ii 07D Containment System Revised 56 109 2.2.01.08 08F T

Containment System T

110 2.2.01.09 10A Untargeted Containment System Revised 113/112 T

111 2.2.01.10a 10C Containment System Deleted 113/112 110 112 2.2.01.10b 10D T

Containment System Deleted 113/112 110 113 2.2.01.10c 10D Containment System 114 2.2.01.11a.i 07E T

Containment System Revised 85/84 T

115 2.2.01.11a.ii 07F T

Containment System Deleted 85/84 114 Page 5 of 38

116 2.2.01.11a.iii 07D T

Containment System T

117 2.2.01.11a.iv 07D T

Containment System T

118 2.2.01.11b 07D T

Containment System T

119 2.2.02.01 14A Passive Containment Cooling System 120 2.2.02.02a 07F T

Passive Containment Cooling System Revised 85/84 T

121 2.2.02.02b 03F T

Passive Containment Cooling System Deleted 85/84 120 122 2.2.02.03a 07B Passive Containment Cooling System Deleted 85/84 120 123 2.2.02.03b 03B Passive Containment Cooling System Deleted 85/84 120 124 2.2.02.04a 07C Passive Containment Cooling System Deleted 85/84 120 125 2.2.02.04b 03C Passive Containment Cooling System Deleted 85/84 120 126 2.2.02.05a.i 14A Passive Containment Cooling System Revised 85/84 T

127 2.2.02.05a.ii 14E T

Passive Containment Cooling System Deleted 85/84 126 128 2.2.02.05a.iii 14F T

Passive Containment Cooling System Deleted 85/84 126 129 2.2.02.05b 03F Passive Containment Cooling System Deleted 85/84 120 130 2.2.02.05c 06F Passive Containment Cooling System 131 2.2.02.06a.i 10E Passive Containment Cooling System Deleted 85/84 126 132 2.2.02.06a.ii 09F Passive Containment Cooling System Deleted 85/84 126 133 2.2.02.06b 10C Passive Containment Cooling System 134 2.2.02.06c R

09X Passive Containment Cooling System Deleted 85/84 135 2.2.02.07a.i 06D Passive Containment Cooling System Deleted 113/112 138 136 2.2.02.07a.ii 06F Passive Containment Cooling System Deleted 113/112 138 137 2.2.02.07a.iii 06A Passive Containment Cooling System Revised 113/112 138 2.2.02.07b.i 06D T

Passive Containment Cooling System Revised Revised 113/112 147/146 T

139 2.2.02.07b.ii 06F T

Passive Containment Cooling System Deleted 113/112 138 Page 6 of 38

140 2.2.02.07b.iii 06F T

Passive Containment Cooling System Deleted 113/112 138 141 2.2.02.07c 06A Passive Containment Cooling System Deleted 113/112 138 142 2.2.02.07d 06D Passive Containment Cooling System Deleted 113/112 138 143 2.2.02.07e.i R

14X Passive Containment Cooling System Deleted 85/84 144 2.2.02.07e.ii 06D Passive Containment Cooling System Deleted 113/112 138 145 2.2.02.07f.i 06D Passive Containment Cooling System Revised 113/112 146 2.2.02.07f.ii 06A Passive Containment Cooling System Deleted 113/112 137 147 2.2.02.08a 06A Passive Containment Cooling System Deleted 113/112 137 148 2.2.02.08b 14D Passive Containment Cooling System Revised Deleted 30 113/112 145 149 2.2.02.08c R

14X Passive Containment Cooling System Deleted 85/84 150 2.2.02.09 10A Passive Containment Cooling System Deleted 113/112 138 151 2.2.02.10a 10C Passive Containment Cooling System Deleted 113/112 138 152 2.2.02.10b 10D Passive Containment Cooling System Deleted 113/112 138 153 2.2.02.10c 10D Passive Containment Cooling System 154 2.2.02.11a.i 07E Passive Containment Cooling System Revised 85/84 155 2.2.02.11a.ii 07F Passive Containment Cooling System Deleted 85/84 154 156 2.2.02.11a.iii 07D Passive Containment Cooling System Deleted 113/112 138 157 2.2.02.11b 07D Passive Containment Cooling System Deleted 113/112 138 158 2.2.03.01 14A T

Passive Core Cooling System T

159 2.2.03.02a 06F T

Passive Core Cooling System Revised 85/84 T

160 2.2.03.02b 03F T

Passive Core Cooling System Deleted 85/84 159 161 2.2.03.03a 06B T

Passive Core Cooling System Deleted 85/84 159 162 2.2.03.03b 03B T

Passive Core Cooling System Deleted 85/84 159 163 2.2.03.04a 06C Passive Core Cooling System Deleted 85/84 159 Page 7 of 38

164 2.2.03.04b 03C Passive Core Cooling System Deleted 85/84 159 165 2.2.03.05a.i 14A Passive Core Cooling System Revised 85/84 T

166 2.2.03.05a.ii 14E T

Passive Core Cooling System Deleted 85/84 165 167 2.2.03.05a.iii 14F T

Passive Core Cooling System Deleted 85/84 165 168 2.2.03.05b 04F T

Passive Core Cooling System Deleted 85/84 159 169 2.2.03.06 03F T

Passive Core Cooling System Revised Deleted 30 85/84 159 170 2.2.03.07a.i 10E T

Passive Core Cooling System Deleted 85/84 165 171 2.2.03.07a.ii 09F T

Passive Core Cooling System Deleted 85/84 165 172 2.2.03.07b 10C Untargeted Passive Core Cooling System 173 2.2.03.07c R

09X Passive Core Cooling System Deleted 85/84 174 2.2.03.08a R

11X Passive Core Cooling System Deleted 85/84 175 2.2.03.08b.01 06D T

Passive Core Cooling System T

176 2.2.03.08b.02 06A T

Passive Core Cooling System T

177 2.2.03.08c.i.01 06D T

Passive Core Cooling System T

178 2.2.03.08c.i.02 06D T

Passive Core Cooling System T

179 2.2.03.08c.i.03 06D T

Passive Core Cooling System Revised 111/110 T

180 2.2.03.08c.i.04 06D T

Passive Core Cooling System Revised 111/110 T

181 2.2.03.08c.ii 06D T

Passive Core Cooling System T

182 2.2.03.08c.iii 03A T

Passive Core Cooling System T

183 2.2.03.08c.iv.01 03A T

Passive Core Cooling System Revised 113/112 T

184 2.2.03.08c.iv.02 03A T

Passive Core Cooling System T

185 2.2.03.08c.iv.03 03A T

Passive Core Cooling System T

186 2.2.03.08c.iv.04 03A T

Passive Core Cooling System T

187 2.2.03.08c.v.01 06A T

Passive Core Cooling System T

Page 8 of 38

188 2.2.03.08c.v.02 06A T

Passive Core Cooling System Deleted 113/112 183 189 2.2.03.08c.vi.01 06A T

Passive Core Cooling System T

190 2.2.03.08c.vi.02 06A T

Passive Core Cooling System T

191 2.2.03.08c.vi.03 06A T

Passive Core Cooling System Revised 81/80 T

192 2.2.03.08c.vii 06A T

Passive Core Cooling System Revised 63 T

193 2.2.03.08c.viii 06A T

Passive Core Cooling System Revised 63 T

194 2.2.03.08c.ix 06A T

Passive Core Cooling System T

195 2.2.03.08c.x 14F T

Passive Core Cooling System Revised 131/130 T

196 2.2.03.08c.xi 06A T

Passive Core Cooling System T

197 2.2.03.08c.xii 03A T

Passive Core Cooling System Revised 23 T

198 2.2.03.08c.xiii 06A Passive Core Cooling System Revised 63 199 2.2.03.08c.xiv 10A Passive Core Cooling System Revised 66 200 2.2.03.08d 06A Passive Core Cooling System 201 2.2.03.09a.i 03D T

Passive Core Cooling System Revised 111/110 T

202 2.2.03.09a.ii 14F Passive Core Cooling System 203 2.2.03.09a.iii 14A Passive Core Cooling System 204 2.2.03.09b 07A T

Passive Core Cooling System T

205 2.2.03.09c 10F Passive Core Cooling System Deleted 139/138 206 2.2.03.10 10A Untargeted Passive Core Cooling System Revised 113/112 T

207 2.2.03.11a.i 10C Passive Core Cooling System 208 2.2.03.11a.ii 10D Passive Core Cooling System Deleted 113/112 206 209 2.2.03.11b.i 10D T

Passive Core Cooling System T

210 2.2.03.11b.ii 10D T

Passive Core Cooling System Deleted 113/112 206 211 2.2.03.11b.iii 10D T

Passive Core Cooling System Deleted 113/112 206 Page 9 of 38

212 2.2.03.11c.i 10D Passive Core Cooling System 213 2.2.03.11c.ii 10D Passive Core Cooling System 214 2.2.03.12a.i 07E T

Passive Core Cooling System Revised 85/84 T

215 2.2.03.12a.ii 07F T

Passive Core Cooling System Deleted 85/84 214 216 2.2.03.12a.iv 07D T

Passive Core Cooling System T

217 2.2.03.12b 07D T

Passive Core Cooling System Deleted 113/112 206 218 2.2.03.13 10A Untargeted Passive Core Cooling System Deleted 113/112 206 219 2.2.04.01 14A Steam Generator System 220 2.2.04.02a 07F Steam Generator System Revised 85/84 221 2.2.04.02b 03F Steam Generator System Deleted 85/84 220 222 2.2.04.03a 07B Untargeted Steam Generator System Deleted 85/84 220 223 2.2.04.03b 03B Steam Generator System Deleted 85/84 220 224 2.2.04.04a 07C Steam Generator System Deleted 85/84 220 225 2.2.04.04b 03C Steam Generator System Deleted 85/84 220 226 2.2.04.05a.i 14A Steam Generator System Revised 85/84 227 2.2.04.05a.ii 14E Steam Generator System Deleted 85/84 226 228 2.2.04.05a.iii 14F Steam Generator System Deleted 85/84 226 229 2.2.04.05b 04F Steam Generator System Deleted 85/84 220 230 2.2.04.06 03F Steam Generator System Revised Deleted 30 85/84 220 231 2.2.04.07a.i 10E Steam Generator System Deleted 85/84 226 232 2.2.04.07a.ii 09F Steam Generator System Deleted 85/84 226 233 2.2.04.07b 10C Steam Generator System 234 2.2.04.07c R

09X Steam Generator System Deleted 85/84 235 2.2.04.08a.i 07A Steam Generator System Page 10 of 38

236 2.2.04.08a.ii 07C Steam Generator System 237 2.2.04.08b.i R

10X Steam Generator System Deleted 85/84 238 2.2.04.08b.ii 06F Steam Generator System 239 2.2.04.08c R

11X Steam Generator System Deleted 85/84 240 2.2.04.09a.i 10D Steam Generator System Deleted 113/112 250 241 2.2.04.09a.ii 10D Steam Generator System 242 2.2.04.09b.i R

14X Steam Generator System Deleted 85/84 243 2.2.04.09b.ii 07F Steam Generator System 244 2.2.04.10 10A Steam Generator System Deleted 113/112 250 245 2.2.04.11a 10C Steam Generator System Deleted 113/112 250 246 2.2.04.11b.i 10D Steam Generator System Deleted 113/112 250 247 2.2.04.11b.ii 10D Steam Generator System Deleted 113/112 250 248 2.2.04.12a.i 07E Steam Generator System Revised 85/84 249 2.2.04.12a.ii 07F Steam Generator System Deleted 85/84 248 250 2.2.04.12a.iii 07D Steam Generator System Revised 113/112 251 2.2.04.12b 07D Steam Generator System Deleted 113/112 250 252 2.2.05.01 12A Untargeted Main Control Room Emergency Habitability System 253 2.2.05.02a 12F Main Control Room Emergency Habitability System Revised Revised 85/84 130/129 254 2.2.05.02b 03F Main Control Room Emergency Habitability System Deleted 85/84 253 255 2.2.05.03a 12B Main Control Room Emergency Habitability System Deleted 85/84 253 256 2.2.05.03b 03B Main Control Room Emergency Habitability System Deleted 85/84 253 257 2.2.05.04a 12C Main Control Room Emergency Habitability System Deleted 85/84 253 258 2.2.05.04b 03C Main Control Room Emergency Habitability System Deleted 85/84 253 259 2.2.05.05a.i 12A Main Control Room Emergency Habitability System Revised 85/84 Page 11 of 38

260 2.2.05.05a.ii 12E Untargeted Main Control Room Emergency Habitability System Deleted 85/84 259 261 2.2.05.05a.iii 12F Main Control Room Emergency Habitability System Deleted 85/84 259 262 2.2.05.05b 04F Main Control Room Emergency Habitability System Deleted 85/84 253 263 2.2.05.06a 10C Main Control Room Emergency Habitability System 264 2.2.05.06b R

09X Main Control Room Emergency Habitability System Deleted 85/84 265 2.2.05.07a.i 12D Untargeted Main Control Room Emergency Habitability System Revised 113/112 T

266 2.2.05.07a.ii 12F Main Control Room Emergency Habitability System 267 2.2.05.07a.iii 12D Main Control Room Emergency Habitability System Deleted 113/112 265 268 2.2.05.07b.i 12D T

Main Control Room Emergency Habitability System Deleted 113/112 265 Added swapped with 265 269 2.2.05.07b.ii 12D T

Main Control Room Emergency Habitability System Deleted 113/112 265 Added swapped with 265 270 2.2.05.07c 12F T

Main Control Room Emergency Habitability System T

271 2.2.05.07d 12D Main Control Room Emergency Habitability System Revised Deleted 56 113/112 265 272 2.2.05.08 10A Main Control Room Emergency Habitability System Deleted 113/112 265 273 2.2.05.09a 10C Main Control Room Emergency Habitability System Deleted 113/112 265 274 2.2.05.09b 10D Main Control Room Emergency Habitability System Deleted 113/112 265 275 2.2.05.10 07D Main Control Room Emergency Habitability System Deleted 113/112 265 276 2.2.05.11 10A Main Control Room Emergency Habitability System Deleted 113/112 265 277 2.2.05.12 16D Untargeted Main Control Room Emergency Habitability System Revised Deleted 30 113/112 265 278 2.3.01.01 14A Component Cooling Water System Deleted 170/168 279 2.3.01.02 R

11X Component Cooling Water System Deleted 85/84 280 2.3.01.03.i 06F Component Cooling Water System 281 2.3.01.03.ii 14D Component Cooling Water System Revised 113/112 282 2.3.01.04 10D Component Cooling Water System Deleted 113/112 281 283 2.3.01.05 10A Component Cooling Water System Deleted 113/112 281 Page 12 of 38

284 2.3.02.01 14A Chemical and Volume Control System Deleted 170/168 285 2.3.02.02a 06F Chemical and Volume Control System Revised 85/84 286 2.3.02.02b 03F Chemical and Volume Control System Deleted 85/84 285 287 2.3.02.03a 06B Chemical and Volume Control System Deleted 85/84 285 288 2.3.02.03b 03B Chemical and Volume Control System Deleted 85/84 285 289 2.3.02.04a 06C Chemical and Volume Control System Deleted 85/84 285 290 2.3.02.04b 03C Chemical and Volume Control System Deleted 85/84 285 291 2.3.02.05.i 07A Chemical and Volume Control System Revised 85/84 292 2.3.02.05.ii 07E Chemical and Volume Control System Deleted 85/84 291 293 2.3.02.05.iii 07F Chemical and Volume Control System Deleted 85/84 291 294 2.3.02.06a.i 08E Chemical and Volume Control System Deleted 85/84 291 295 2.3.02.06a.ii 09F Chemical and Volume Control System Deleted 85/84 291 296 2.3.02.06b 08C Chemical and Volume Control System 297 2.3.02.06c R

09X Chemical and Volume Control System Deleted 85/84 298 2.3.02.07a R

11X Chemical and Volume Control System Deleted 85/84 299 2.3.02.07b R

10X Chemical and Volume Control System Deleted 85/84 300 2.3.02.07c R

10X Chemical and Volume Control System Deleted 85/84 301 2.3.02.08a.i 06D Chemical and Volume Control System Revised 113/112 302 2.3.02.08a.ii 06A Chemical and Volume Control System Revised 78/77 303 2.3.02.08a.iii 06D Chemical and Volume Control System Revised 78/77 304 2.3.02.08b 06D Chemical and Volume Control System Deleted 113/112 301 305 2.3.02.09 10A Chemical and Volume Control System Deleted 113/112 301 306 2.3.02.10a 10C Chemical and Volume Control System Deleted 113/112 301 307 2.3.02.10b.i 10D Chemical and Volume Control System Deleted 113/112 301 Page 13 of 38

308 2.3.02.10b.ii 10D Chemical and Volume Control System Deleted 113/112 301 309 2.3.02.11a.i 07E Chemical and Volume Control System Revised 85/84 310 2.3.02.11a.ii 07F Chemical and Volume Control System Deleted 85/84 309 311 2.3.02.11a.iii 07D Chemical and Volume Control System Deleted 113/112 301 312 2.3.02.11a.iv 07D Chemical and Volume Control System Deleted 113/112 301 313 2.3.02.11b 07D Chemical and Volume Control System Deleted 113/112 301 314 2.3.02.12a 10D Chemical and Volume Control System Deleted 113/112 301 315 2.3.02.12b 06D Chemical and Volume Control System Deleted 113/112 301 316 2.3.02.13 10A Chemical and Volume Control System Deleted 113/112 301 317 2.3.02.14 03F Chemical and Volume Control System Revised 125/124 318 2.3.03.01 08A Standby Diesel Fuel Oil System Deleted 170/168 319 2.3.03.02 06F Standby Diesel Fuel Oil System 320 2.3.03.03a 06A Standby Diesel Fuel Oil System 321 2.3.03.03b 06A Standby Diesel Fuel Oil System 322 2.3.03.03c 06D Standby Diesel Fuel Oil System 323 2.3.03.03d 06A Standby Diesel Fuel Oil System 324 2.3.03.04 10D Standby Diesel Fuel Oil System Revised 113/112 325 2.3.03.05 10A Standby Diesel Fuel Oil System Deleted 113/112 324 326 2.3.04.01 15A Fire Protection System Deleted 170/168 327 2.3.04.02.i 15A Fire Protection System Revised 92/91 328 2.3.04.02.ii 04F Fire Protection System Revised 92/91 329 2.3.04.03 R

11X Fire Protection System Deleted 85/84 330 2.3.04.04.i 11A Fire Protection System Revised 113/112 331 2.3.04.04.ii 15D Untargeted Fire Protection System Page 14 of 38

332 2.3.04.05 10A Fire Protection System 333 2.3.04.06 15A Fire Protection System Deleted 113/112 330 334 2.3.04.07 15A Fire Protection System Revised Deleted 107/106 113/112 330 335 2.3.04.08 15D Fire Protection System Revised 58 336 2.3.04.09 15A Fire Protection System Revised 58 337 2.3.04.10 15C Untargeted Fire Protection System 338 2.3.04.11 15A Fire Protection System 339 2.3.05.01 13A Mechanical Handling System Deleted 170/168 340 2.3.05.02.i 13A Mechanical Handling System Revised 85/84 341 2.3.05.02.ii 13E Mechanical Handling System Deleted 85/84 340 342 2.3.05.02.iii 13F Mechanical Handling System Deleted 85/84 340 343 2.3.05.03a.i 13F Mechanical Handling System 344 2.3.05.03a.ii 13E Mechanical Handling System Revised 113/112 345 2.3.05.03a.iii 13C Mechanical Handling System Deleted 113/112 344 346 2.3.05.03b.i 13F Mechanical Handling System 347 2.3.05.03b.ii 13E Mechanical Handling System Deleted 113/112 348 348 2.3.05.03b.iii 13C Untargeted Mechanical Handling System Revised 113/112 349 2.3.05.03c.i 13F Mechanical Handling System 350 2.3.05.03c.ii 13C Mechanical Handling System 351 2.3.05.03d.i 13F Mechanical Handling System 352 2.3.05.03d.ii 13C Mechanical Handling System 353 2.3.05.04 13D Mechanical Handling System Deleted 113/112 348 354 2.3.06.01 14A Normal Residual Heat Removal System Deleted 170/168 355 2.3.06.02a 06F Normal Residual Heat Removal System Revised 85/84 Page 15 of 38

356 2.3.06.02b 03F Normal Residual Heat Removal System Deleted 85/84 355 357 2.3.06.03a 06B Normal Residual Heat Removal System Deleted 85/84 355 358 2.3.06.03b 03B Normal Residual Heat Removal System Deleted 85/84 355 359 2.3.06.04a 06C Normal Residual Heat Removal System Deleted 85/84 355 360 2.3.06.04b 03C Normal Residual Heat Removal System Deleted 85/84 355 361 2.3.06.05a.i 06A Normal Residual Heat Removal System Revised 85/84 362 2.3.06.05a.ii 06E Untargeted Normal Residual Heat Removal System Deleted 85/84 361 363 2.3.06.05a.iii 06F Normal Residual Heat Removal System Deleted 85/84 361 364 2.3.06.05b 04F Normal Residual Heat Removal System Deleted 85/84 355 365 2.3.06.06 03F Normal Residual Heat Removal System Revised Deleted 30 85/84 355 366 2.3.06.07a.i 08E Normal Residual Heat Removal System Deleted 85/84 361 367 2.3.06.07a.ii 09F Normal Residual Heat Removal System Deleted 85/84 361 368 2.3.06.07b 10C Normal Residual Heat Removal System 369 2.3.06.07c R

09X Normal Residual Heat Removal System Deleted 85/84 370 2.3.06.08a R

11X Normal Residual Heat Removal System Deleted 85/84 371 2.3.06.08b R

14X Normal Residual Heat Removal System Deleted 85/84 372 2.3.06.09a.i 07F Normal Residual Heat Removal System Revised 104/103 373 2.3.06.09a.ii 07F Normal Residual Heat Removal System Revised 104/103 374 2.3.06.09b.i 06F Normal Residual Heat Removal System 375 2.3.06.09b.ii 06D Normal Residual Heat Removal System Revised Revised 113/112 152/151 376 2.3.06.09b.iii 03A Normal Residual Heat Removal System Deleted 113/112 375 377 2.3.06.09b.iv 03A Normal Residual Heat Removal System Deleted 113/112 375 378 2.3.06.09b.v 03A Normal Residual Heat Removal System Deleted 113/112 375 379 2.3.06.09c 06D Normal Residual Heat Removal System Deleted 113/112 375 Page 16 of 38

380 2.3.06.09d 06D Normal Residual Heat Removal System Deleted 113/112 375 381 2.3.06.10 10A Normal Residual Heat Removal System Deleted 113/112 382 382 2.3.06.11a 10C Normal Residual Heat Removal System Revised Revised 113/112 125/124 383 2.3.06.11b 10D Normal Residual Heat Removal System Deleted 113/112 382 384 2.3.06.12a.i 07E Normal Residual Heat Removal System Revised 85/84 385 2.3.06.12a.ii 07F Normal Residual Heat Removal System Deleted 85/84 384 386 2.3.06.12a.iii 07D Normal Residual Heat Removal System Deleted 113/112 375 387 2.3.06.12a.iv 07D Normal Residual Heat Removal System Deleted 113/112 375 388 2.3.06.12b 07D Normal Residual Heat Removal System Deleted 113/112 382 389 2.3.06.13 10D Normal Residual Heat Removal System Deleted 113/112 382 390 2.3.06.14 10A Normal Residual Heat Removal System Deleted 113/112 382 391 2.3.07.01 14A Spent Fuel Pool Cooling System Deleted 170/168 392 2.3.07.02a 07F Spent Fuel Pool Cooling System Revised 85/84 393 2.3.07.02b 03F Spent Fuel Pool Cooling System Deleted 85/84 392 394 2.3.07.03 03B Spent Fuel Pool Cooling System Deleted 85/84 392 395 2.3.07.04 03C Spent Fuel Pool Cooling System Deleted 85/84 392 396 2.3.07.05.i 07A Spent Fuel Pool Cooling System Revised 85/84 397 2.3.07.05.ii 07E Spent Fuel Pool Cooling System Deleted 85/84 396 398 2.3.07.05.iii 07F Spent Fuel Pool Cooling System Deleted 85/84 396 399 2.3.07.06a 10C Spent Fuel Pool Cooling System 400 2.3.07.06b R

09X Spent Fuel Pool Cooling System Deleted 85/84 401 2.3.07.07a R

11X Spent Fuel Pool Cooling System Deleted 85/84 402 2.3.07.07b.i 06A Spent Fuel Pool Cooling System Revised 126/125 403 2.3.07.07b.ii 06A Spent Fuel Pool Cooling System Revised 126/125 Page 17 of 38

404 2.3.07.07b.iii R

14X Spent Fuel Pool Cooling System Deleted 85/84 405 2.3.07.07b.iv R

06X Spent Fuel Pool Cooling System Deleted 85/84 406 2.3.07.07b.v R

06X Spent Fuel Pool Cooling System Deleted 85/84 407 2.3.07.07b.vi R

14X Spent Fuel Pool Cooling System Deleted 85/84 408 2.3.07.07c 07D Spent Fuel Pool Cooling System Revised 113/112 409 2.3.07.08.i 06F Spent Fuel Pool Cooling System 410 2.3.07.08.ii 06D Spent Fuel Pool Cooling System Deleted 113/112 408 411 2.3.07.09 10A Spent Fuel Pool Cooling System Deleted 113/112 408 412 2.3.07.10 10D Spent Fuel Pool Cooling System Deleted 113/112 408 413 2.3.07.11 10A Spent Fuel Pool Cooling System Deleted 113/112 408 414 2.3.08.01 14A Service Water System Deleted 170/168 415 2.3.08.02.i 06D Service Water System Revised 113/112 416 2.3.08.02.ii 06F Service Water System 417 2.3.08.02.iii 01D Untargeted Service Water System 418 2.3.08.03 10C Service Water System Deleted 113/112 415 419 2.3.08.04 10A Service Water System Deleted 113/112 415 420 2.3.09.01 06A Containment Hydrogen Control System Deleted 170/168 421 2.3.09.02a 10C Containment Hydrogen Control System 422 2.3.09.02b 10C Containment Hydrogen Control System 423 2.3.09.03.i 06A Containment Hydrogen Control System Revised Deleted 61 113/112 424 424 2.3.09.03.ii 06D Containment Hydrogen Control System Revised Revised 61 113/112 425 2.3.09.03.iii 11A Containment Hydrogen Control System Revised 84/83 426 2.3.09.03.iv 06A Containment Hydrogen Control System 427 2.3.09.04a 10D Containment Hydrogen Control System Deleted 113/112 424 Page 18 of 38

428 2.3.09.04b 10D Containment Hydrogen Control System Revised 158/156 429 2.3.09.05 10A Containment Hydrogen Control System Deleted 113/112 424 430 2.3.10.01 14A Liquid Radwaste System Deleted 170/168 431 2.3.10.02a 07F Liquid Radwaste System Revised 85/84 432 2.3.10.02b 03F Liquid Radwaste System Deleted 85/84 431 433 2.3.10.03a 07B Liquid Radwaste System Deleted 85/84 431 434 2.3.10.03b 03B Liquid Radwaste System Deleted 85/84 431 435 2.3.10.04a 07C Liquid Radwaste System Deleted 85/84 431 436 2.3.10.04b 03C Liquid Radwaste System Deleted 85/84 431 437 2.3.10.05a.i 06A Liquid Radwaste System Revised 85/84 438 2.3.10.05a.ii 06E Liquid Radwaste System Deleted 85/84 437 439 2.3.10.05a.iii 06F Liquid Radwaste System Deleted 85/84 437 440 2.3.10.05b 04F Liquid Radwaste System Deleted 85/84 431 441 2.3.10.06a R

11X Liquid Radwaste System Deleted 85/84 442 2.3.10.06b R

07X Liquid Radwaste System Deleted 85/84 443 2.3.10.07a.i 10A Liquid Radwaste System Revised Deleted 30 113/112 444 444 2.3.10.07a.ii 10F Liquid Radwaste System Revised Revised Revised 30 113/112 140/139 445 2.3.10.07b 10D Liquid Radwaste System Deleted 113/112 444 446 2.3.10.08 10C Liquid Radwaste System Deleted 113/112 444 447 2.3.10.09 07D Liquid Radwaste System Deleted 113/112 444 448 2.3.10.10 10A Liquid Radwaste System Deleted 113/112 444 449 2.3.11.01 14A Gaseous Radwaste System Deleted 170/168 450 2.3.11.02.i 06A Gaseous Radwaste System Revised 85/84 Page 19 of 38

451 2.3.11.02.ii 06E Gaseous Radwaste System Deleted 85/84 450 452 2.3.11.02.iii 06F Gaseous Radwaste System Deleted 85/84 450 453 2.3.11.03a 06F Gaseous Radwaste System Revised 158/156 454 2.3.11.03b 10C Gaseous Radwaste System 455 2.3.11.03c 10C Gaseous Radwaste System 456 2.3.12.01 06A Solid Radwaste System Deleted 170/168 457 2.3.12.02 06F Solid Radwaste System 458 2.3.13.01 14A Primary Sampling System Deleted 170/168 459 2.3.13.02 07F Primary Sampling System Revised 85/84 460 2.3.13.03 07B Primary Sampling System Deleted 85/84 459 461 2.3.13.04 07C Primary Sampling System Deleted 85/84 459 462 2.3.13.05.i 07A Primary Sampling System Revised 85/84 463 2.3.13.05.ii 07E Primary Sampling System Deleted 85/84 462 464 2.3.13.05.iii 07F Primary Sampling System Deleted 85/84 462 465 2.3.13.06a.i 08E Primary Sampling System Deleted 85/84 462 466 2.3.13.06a.ii 09F Primary Sampling System Deleted 85/84 462 467 2.3.13.06b 10C Primary Sampling System 468 2.3.13.06c R

09X Primary Sampling System Deleted 85/84 469 2.3.13.07 R

11X Primary Sampling System Deleted 85/84 470 2.3.13.08 07D Primary Sampling System Revised 113/112 471 2.3.13.09 10A Primary Sampling System Deleted 113/112 470 472 2.3.13.10a 10C Primary Sampling System Deleted 113/112 470 473 2.3.13.10b 10D Primary Sampling System Deleted 113/112 470 474 2.3.13.11a 07D Primary Sampling System Deleted 10 Page 20 of 38

475 2.3.13.11b 07D Primary Sampling System Deleted 113/112 470 476 2.3.13.12 10D Primary Sampling System Deleted 113/112 470 477 2.3.14.01 14A Demineralized Water Transfer and Storage System Deleted 170/168 478 2.3.14.02 R

11X Demineralized Water Transfer and Storage System Deleted 85/84 479 2.3.14.03 06A Demineralized Water Transfer and Storage System Revised 30 480 2.3.14.04 10A Demineralized Water Transfer and Storage System Revised 30 481 2.3.15.01 14A Compressed and Instrument Air System Deleted 170/168 482 2.3.15.02 R

11X Compressed and Instrument Air System Deleted 85/84 483 2.3.15.03 10A Compressed and Instrument Air System 484 2.3.19.01a 10A Communication on System Deleted 113/112 486 485 2.3.19.01b 10A Communication System Deleted 113/112 486 486 2.3.19.02a 10D Communication System Revised 113/112 487 2.3.19.02b 10D Communication System Deleted 113/112 486 488 2.3.29.01 03A Radioactive Waste Drain System Deleted 170/168 489 2.3.29.02 03D Radioactive Waste Drain System Revised 113/112 490 2.3.29.03 03D Radioactive Waste Drain System Deleted 113/112 489 491 2.3.29.04 10C Radioactive Waste Drain System Revised 96/95 492 2.4.01.01 14A Main and Startup Feedwater System Deleted 170/168 493 2.4.01.02 14D Main and Startup Feedwater System Revised 113/112 494 2.4.01.03 10D Main and Startup Feedwater System Deleted 113/112 493 495 2.4.01.04 10A Main and Startup Feedwater System Deleted 113/112 493 496 2.4.02.01 14A Main Turbine System Deleted 170/168 497 2.4.02.02a 10D Main Turbine System Revised 113/112 498 2.4.02.02b 10D Main Turbine System Page 21 of 38

499 2.4.02.02c 10D Main Turbine System Deleted 113/112 497 500 2.4.02.03.i 10F Main Turbine System 501 2.4.02.03.ii 10D Main Turbine System Deleted 113/112 497 502 2.4.02.03.iii 10F Main Turbine System 503 2.4.06.01 14A Condensate System Deleted 170/168 504 2.4.06.02 10A Condensate System 505 2.5.01.01 14A Diverse Actuation System Deleted 85/84 506 2.5.01.02a 10D Diverse Actuation System Revised Revised Revised 38 67 113/112 507 2.5.01.02b 10D Diverse Actuation System Deleted 113/112 506 508 2.5.01.02c.i 10D Diverse Actuation System Revised Revised Deleted 38 67 113/112 506 509 2.5.01.02c.ii 10D Diverse Actuation System Deleted 113/112 506 510 2.5.01.02d 10A Diverse Actuation System Deleted 113/112 506 511 2.5.01.03a 10A Diverse Actuation System 512 2.5.01.03b 10A Diverse Actuation System 513 2.5.01.03c 10F T

Diverse Actuation System T

514 2.5.01.03d 10E T

Diverse Actuation System T

515 2.5.01.03e 10A Diverse Actuation System 516 2.5.01.03f 10C Diverse Actuation System Deleted 113/112 506 517 2.5.01.03g 10D Diverse Actuation System Deleted 113/112 506 518 2.5.01.03h 10E Diverse Actuation System 519 2.5.01.04 10F T

Diverse Actuation System T

520 2.5.01.05 R

10X Diverse Actuation System Deleted 85/84 521 2.5.02.01 14A Protection and Safety Monitoring System Deleted 85/84 Page 22 of 38

522 2.5.02.02.i 10A Protection and Safety Monitoring System Revised 85/84 T

523 2.5.02.02.ii 10E T

Protection and Safety Monitoring System Deleted 85/84 522 524 2.5.02.02.iii 10F T

Protection and Safety Monitoring System Deleted 85/84 522 525 2.5.02.03 10E T

Protection and Safety Monitoring System Deleted 85/84 522 526 2.5.02.04 10E T

Protection and Safety Monitoring System Deleted 85/84 522 527 2.5.02.05a 10C Untargeted Protection and Safety Monitoring System 528 2.5.02.05b R

09X Protection and Safety Monitoring System Deleted 85/84 529 2.5.02.06a.i 10D T

Protection and Safety Monitoring System T

530 2.5.02.06a.ii 10D T

Protection and Safety Monitoring System Revised 113/112 T

531 2.5.02.06b 10D T

Protection and Safety Monitoring System Deleted 113/112 530 532 2.5.02.06c.i 10D T

Protection and Safety Monitoring System T

533 2.5.02.06c.ii 10D T

Protection and Safety Monitoring System Deleted 113/112 530 534 2.5.02.07a 10E T

Protection and Safety Monitoring System T

535 2.5.02.07b 10E T

Protection and Safety Monitoring System T

536 2.5.02.07c 10E T

Protection and Safety Monitoring System T

537 2.5.02.07d 10E T

Protection and Safety Monitoring System T

538 2.5.02.07e 10D T

Protection and Safety Monitoring System T

539 2.5.02.08a.i 10A Untargeted Protection and Safety Monitoring System Deleted 113/112 530 540 2.5.02.08a.ii 10D T

Protection and Safety Monitoring System T

541 2.5.02.08a.iii 10D T

Protection and Safety Monitoring System Deleted 113/112 530 542 2.5.02.08b.i 10A T

Protection and Safety Monitoring System T

543 2.5.02.08b.ii 10D T

Protection and Safety Monitoring System T

544 2.5.02.08c 10A Untargeted Protection and Safety Monitoring System Deleted 113/112 530 545 2.5.02.09a 10D T

Protection and Safety Monitoring System Deleted 113/112 530 Page 23 of 38

546 2.5.02.09b 10D T

Protection and Safety Monitoring System Deleted 113/112 530 547 2.5.02.09c 10D T

Protection and Safety Monitoring System Deleted 113/112 530 548 2.5.02.09d 10D T

Protection and Safety Monitoring System T

549 2.5.02.10 10F T

Protection and Safety Monitoring System T

550 2.5.02.11 10F T

Protection and Safety Monitoring System T

551 2.5.02.12 10F T

Protection and Safety Monitoring System T

552 2.5.02.13 10F T

Protection and Safety Monitoring System T

553 2.5.02.14 10F T

Protection and Safety Monitoring System T

554 2.5.03.01 10A Plant Control System Deleted 85/84 555 2.5.03.02 10D Plant Control System 556 2.5.04.01 10A Data Display and Processing System 557 2.5.04.02.i 10A Data Display and Processing System Revised 113/112 558 2.5.04.02.ii 10D Data Display and Processing System Deleted 113/112 557 559 2.5.04.02.iii 10D Data Display and Processing System Deleted 113/112 557 560 2.5.04.03 10D Data Display and Processing System 561 C.2.5.04.04a 10A T

Data Display and Processing System Revised 113/112 T

562 C.2.5.04.04b 10F Data Display and Processing System Deleted 113/112 561 563 C.2.5.04.04c 10F T

Data Display and Processing System Deleted 113/112 561 564 2.5.05.01 14A In-Core Instrumentation System Deleted 170/168 565 2.5.05.02.i 06A In-Core Instrumentation System Revised 85/84 566 2.5.05.02.ii 06E In-Core Instrumentation System Deleted 85/84 565 567 2.5.05.02.iii 06F In-Core Instrumentation System Deleted 85/84 565 568 2.5.05.03a.i 10E In-Core Instrumentation System Deleted 85/84 565 569 2.5.05.03a.ii 09F In-Core Instrumentation System Deleted 85/84 565 Page 24 of 38

570 2.5.05.03b 10A In-Core Instrumentation System 571 2.5.05.03c R

09X In-Core Instrumentation System Deleted 85/84 572 2.5.05.04 10A In-Core Instrumentation System 573 2.5.06.01 10A Special Monitoring System Deleted 170/168 574 2.5.06.02 10A Special Monitoring System 575 2.5.09.01 10A Seismic Monitoring System Deleted 170/168 576 2.5.09.02 10E Seismic Monitoring System 577 2.5.09.03 10E Seismic Monitoring System 578 2.6.01.01 08A Main AC Power System Deleted 170/168 579 2.6.01.02.i 08A Main AC Power System Revised 85/84 580 2.6.01.02.ii 08E Main AC Power System Deleted 85/84 579 581 2.6.01.02.iii 08F Main AC Power System Deleted 85/84 579 582 2.6.01.03a 08C Main AC Power System 583 2.6.01.03b R

09X Main AC Power System Deleted 85/84 584 2.6.01.04a 08C Main AC Power System Deleted 113/112 588 585 2.6.01.04b R

08X Main AC Power System Deleted 85/84 586 2.6.01.04c 08D Main AC Power System 587 2.6.01.04d 08D Main AC Power System 588 2.6.01.04e 10C Main AC Power System Revised 113/112 589 2.6.01.04f 10C Main AC Power System Deleted 113/112 588 590 2.6.01.05 10D Main AC Power System Deleted 113/112 588 591 2.6.01.06 10A Main AC Power System Deleted 113/112 588 592 2.6.02.01 08A Non-Class 1E DC &

Uninterruptible Power Supply System Deleted 85/84 593 2.6.02.02a 08D Non-Class 1E DC &

Uninterruptible Power Supply System Revised 18 Page 25 of 38

594 2.6.02.02b 08D Non-Class 1E DC &

Uninterruptible Power Supply System Revised 18 595 2.6.02.02c 08D Non-Class 1E DC &

Uninterruptible Power Supply System Revised 18 596 2.6.03.01 08A Class 1E DC &

Uninterruptible Power Supply System Deleted 85/84 597 2.6.03.02.i 08A Class 1E DC &

Uninterruptible Power Supply System Revised 85/84 T

598 2.6.03.02.ii 08E T

Class 1E DC &

Uninterruptible Power Supply System Deleted 85/84 597 599 2.6.03.02.iii 08F T

Class 1E DC &

Uninterruptible Power Supply System Deleted 85/84 597 600 2.6.03.03 R

09X Class 1E DC &

Uninterruptible Power Supply System Deleted 85/84 601 2.6.03.04a 08C Untargeted Class 1E DC &

Uninterruptible Power Supply System 602 2.6.03.04b 08E T

Class 1E DC &

Uninterruptible Power Supply System Revised 158/156 T

603 2.6.03.04c 08D T

Class 1E DC &

Uninterruptible Power Supply System Revised 113/112 T

604 2.6.03.04d 08D T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 605 2.6.03.04e 08D Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 606 2.6.03.04f 08D T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 607 2.6.03.04g 08D T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 608 2.6.03.04h 08C T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 609 2.6.03.04i 08D T

Class 1E DC &

Uninterruptible Power Supply System Revised Revised 30 121/120 T

610 2.6.03.05a 08D T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 611 2.6.03.05b 08D T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 612 2.6.03.05c 08D T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 613 2.6.03.05d.i 08A Untargeted Class 1E DC &

Uninterruptible Power Supply System Revised 113/112 614 2.6.03.05d.ii 08A Untargeted Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 613 615 2.6.03.06 10A Untargeted Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 616 2.6.03.07 08F T

Class 1E DC &

Uninterruptible Power Supply System Revised 113/112 T

Page 26 of 38

617 2.6.03.08 08F T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 616 618 2.6.03.09 08F T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 616 619 2.6.03.10 08F T

Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 616 620 2.6.03.11 10A Untargeted Class 1E DC &

Uninterruptible Power Supply System Deleted 113/112 603 621 2.6.04.01 08A Onsite Standby Power System Deleted 170/168 622 2.6.04.02a 08D Onsite Standby Power System Revised 113/112 623 2.6.04.02b 08D Onsite Standby Power System Deleted 113/112 622 624 2.6.04.02c 08D Onsite Standby Power System 625 2.6.04.03 10A Onsite Standby Power System Deleted 113/112 622 626 2.6.04.04 10D Onsite Standby Power System Deleted 113/112 622 627 2.6.05.01 08A Lighting System Deleted 85/84 628 2.6.05.02.i 08A Lighting System Deleted 113/112 629 629 2.6.05.02.ii 08D Lighting System Revised 113/112 630 2.6.05.03.i 08A Lighting System Revised 85/84 631 2.6.05.03.ii 08F Lighting System Deleted 85/84 630 632 2.6.05.04 R

09X Lighting System Deleted 85/84 633 2.6.05.05.i 08D Lighting System Deleted 113/112 629 634 2.6.05.05.ii 08D Lighting System Deleted 113/112 629 635 2.6.05.06.i 08D Lighting System Deleted 113/112 629 636 2.6.05.06.ii 08D Lighting System Deleted 113/112 629 637 2.6.06.01.i 08A Grounding and Lightning Protection System Revised Revised Revised 23 113/112 158/156 638 2.6.06.01.ii 08A Grounding and Lightning Protection System Revised Deleted 23 113/112 637 639 2.6.06.01.iii 08A Grounding and Lightning Protection System Revised Deleted 23 113/112 637 640 2.6.06.01.iv 08A Grounding and Lightning Protection System Revised Deleted 23 113/112 637 Page 27 of 38

641 2.6.09.01 R

17X Plant Security System Deleted 85/84 642 2.6.09.03 R

17X Plant Security System Deleted 85/84 643 2.6.09.04 R

17X Plant Security System Deleted 85/84 644 2.6.09.05a 17D T

Plant Security System Revised 113/112 T

645 2.6.09.05b 17A T

Plant Security System T

646 2.6.09.05c 17F T

Plant Security System T

647 2.6.09.06 17A T

Plant Security System T

648 2.6.09.07a 17A T

Plant Security System Deleted 113/112 667 649 2.6.09.07b 17A T

Plant Security System Deleted 113/112 667 650 2.6.09.08 17C T

Plant Security System T

651 2.6.09.09 17D T

Plant Security System Deleted 113/112 670 652 2.6.09.13a 17D T

Plant Security System Revised 113/112 T

653 2.6.09.13b 17D T

Plant Security System Deleted 113/112 652 654 2.6.09.13c 17D T

Plant Security System T

655 2.6.09.15a 17D T

Plant Security System Revised 113/112 T

656 2.6.09.15b 17D T

Plant Security System Deleted 113/112 644 657 2.6.09.16 17D T

Plant Security System Deleted 113/112 655 658 C.2.6.09.01 17E T

Physical Security T

659 C.2.6.09.02 17A T

Physical Security T

660 C.2.6.09.03a 17A T

Physical Security T

661 C.2.6.09.03b 17A T

Physical Security Revised 113/112 T

662 C.2.6.09.04a 17D T

Physical Security Deleted 113/112 661 663 C.2.6.09.04b 17D T

Physical Security Deleted 113/112 661 664 C.2.6.09.05a 17A T

Physical Security Revised 113/112 T

Page 28 of 38

665 C.2.6.09.05b 17D T

Physical Security Deleted 113/112 664 666 C.2.6.09.06 17D T

Physical Security T

667 C.2.6.09.07 17A T

Physical Security Revised 113/112 T

668 C.2.6.09.08a 17A T

Physical Security Revised 113/112 T

669 C.2.6.09.08b 17A T

Physical Security Deleted 113/112 668 670 C.2.6.09.09 17D T

Physical Security Revised 113/112 T

671 C.2.6.12.01 08A Transmission SWYD &

Off-site Power System 672 C.2.6.12.02 08F Transmission SWYD &

Off-site Power System 673 C.2.6.12.03 08F Transmission SWYD &

Off-site Power System 674 C.2.6.12.04 08F Transmission SWYD &

Off-site Power System 675 C.2.6.12.05 08F T

Transmission SWYD &

Off-site Power System T

676 C.2.6.12.06 08F T

Transmission SWYD &

Off-site Power System T

677 2.7.01.01 12A Nuclear Island Nonradioactive Ventilation System Deleted 170/168 678 2.7.01.02a 12F Nuclear Island Nonradioactive ve Ventilation System Revised 85/84 679 2.7.01.02b 12F Nuclear Island Nonradioactive Ventilation System Revised Deleted 23 85/84 678 680 2.7.01.03a 12B Nuclear Island Nonradioactive Ventilation System Deleted 85/84 678 681 2.7.01.03b 12B Untargeted Nuclear Island Nonradioactive Ventilation System Deleted 85/84 678 682 2.7.01.04a 12C Untargeted Nuclear Island Nonradioactive Ventilation System Deleted 85/84 678 683 2.7.01.04b 12C Nuclear Island Nonradioactive Ventilation System Deleted 85/84 678 684 2.7.01.05.i 12A Nuclear Island Nonradioactive Ventilation System Revised 85/84 685 2.7.01.05.ii 12E Nuclear Island Nonradioactive Ventilation System Deleted 85/84 684 686 2.7.01.05.iii 12F Nuclear Island Nonradioactive Ventilation System Deleted 85/84 684 687 2.7.01.06a 10C Nuclear Island Nonradioactive Ventilation System 688 2.7.01.06b R

09X Nuclear Island Nonradioactive Ventilation System Deleted 85/84 Page 29 of 38

689 2.7.01.07 R

07X Nuclear Island Nonradioactive Ventilation System Deleted 85/84 690 2.7.01.08a R

10X Nuclear Island Nonradioactive Ventilation System Deleted 85/84 691 2.7.01.08b R

10X Nuclear Island Nonradioactive Ventilation System Deleted 85/84 692 2.7.01.08c R

10X Nuclear Island Nonradioactive Ventilation System Deleted 85/84 693 2.7.01.08d 12D Nuclear Island Nonradioactive Ventilation System Deleted 113/112 700 694 2.7.01.09 10A Nuclear Island Nonradioactive Ventilation System Deleted 113/112 700 695 2.7.01.10a 10C Nuclear Island Nonradioactive Ventilation System Deleted 113/112 700 696 2.7.01.10b 07D Nuclear Island Nonradioactive Ventilation System Deleted 113/112 700 697 2.7.01.11 07D Nuclear Island Nonradioactive Ventilation System Deleted 113/112 700 698 2.7.01.12 10D Untargeted Nuclear Island Nonradioactive Ventilation System Deleted 113/112 700 699 2.7.01.13 10A Untargeted Nuclear Island Nonradioactive Ventilation System Deleted 113/112 700 700 2.7.01.14 12D Nuclear Island Nonradioactive Ventilation System Revised 113/112 701 2.7.02.01 12A Central Chilled Water System Deleted 170/168 702 2.7.02.02 R

11X Central Chilled Water System Deleted 85/84 703 2.7.02.03a 12D Central Chilled Water System Revised Revised 93/92 113/112 704 2.7.02.03b 12F Central Chilled Water System 705 2.7.02.04 12D Central Chilled Water System Deleted 113/112 703 706 2.7.02.05 10A Central Chilled Water System Deleted 113/112 703 707 2.7.03.01 12A Annex/Auxiliary Building Nonradioactive Ventilation System Deleted 170/168 708 2.7.03.02a R

12X Annex/Auxiliary Building Nonradioactive Ventilation System Deleted 85/84 709 2.7.03.02b R

12X Annex/Auxiliary Building Nonradioactive Ventilation System Deleted 85/84 710 2.7.03.03 12D Annex/Auxiliary Building Nonradioactive Ventilation System Revised 113/112 711 2.7.03.04 10A Annex/Auxiliary Building Nonradioactive Ventilation System Deleted 113/112 710 Page 30 of 38

712 2.7.04.01 12A Diesel Generator Building Ventilation System Deleted 170/168 713 2.7.04.02a R

12X Diesel Generator Building Ventilation System Deleted 85/84 714 2.7.04.02b R

12X Diesel Generator Building Ventilation System Deleted 85/84 715 2.7.04.02c R

12X Diesel Generator Building Ventilation System Deleted 85/84 716 2.7.04.03 12D Diesel Generator Building Ventilation System Revised 113/112 717 2.7.04.04 10A Diesel Generator Building Ventilation System Deleted 113/112 716 718 2.7.05.01 12A Radiologically Controlled Area Ventilation System Deleted 170/168 719 2.7.05.02.i 12D Radiologically Controlled Area Ventilation System Revised Revised 113/112 129/128 720 2.7.05.02.ii 12F Radiologically Controlled Area Ventilation System Deleted 113/112 719 721 2.7.05.02.iii 12F Radiologically Controlled Area Ventilation System Deleted 113/112 719 722 2.7.05.03 10A Radiologically Controlled Area Ventilation System Deleted 113/112 719 723 2.7.06.01 12A Containment Air Filtration System Deleted 170/168 724 2.7.06.02.i R

11X Containment Air Filtration System Deleted 85/84 725 2.7.06.02.ii 07D T

Containment Air Filtration System T

726 2.7.06.03.i 12D Containment Air Filtration System Revised 113/112 727 2.7.06.03.ii 12D Containment Air Filtration System Deleted 113/112 726 728 2.7.06.03.iii 12A Containment Air Filtration System Deleted 113/112 726 729 2.7.06.04 12D Containment Air Filtration System Deleted 113/112 726 730 2.7.06.05 10A Containment Air Filtration System Deleted 113/112 726 731 2.7.07.01 12A Containment Recirculation Cooling System Deleted 170/168 732 2.7.07.02 10A Containment Recirculation Cooling System 733 3.1.00.01 18A Emergency Response Facilities Deleted 95/94 734 3.1.00.02 18D Emergency Response Facilities Deleted 95/94 Page 31 of 38

735 3.1.00.03 18A Untargeted Emergency Response Facilities 736 3.1.00.04 18D Emergency Response Facilities Deleted 95/94 737 3.1.00.05 18A T

Emergency Response Facilities T

738 3.1.00.06 R

18X Emergency Response Facilities Deleted 85/84 739 3.2.00.01a 16F T

Human Factors Engineering T

740 3.2.00.01b 16F T

Human Factors Engineering Revised 56 T

741 3.2.00.01c.i 16F T

Human Factors Engineering T

742 3.2.00.01c.ii 16E T

Human Factors Engineering T

743 3.2.00.01d 16F T

Human Factors Engineering T

744 3.2.00.01e 16F T

Human Factors Engineering T

Added 745 3.2.00.02 16A Human Factors Engineering 746 3.2.00.03.i R

16X Human Factors Engineering Deleted 85/84 747 3.2.00.03.ii R

16X Human Factors Engineering Deleted 85/84 748 3.2.00.03.iii R

16X Human Factors Engineering Deleted 85/84 749 3.2.00.03.iv R

16X Human Factors Engineering Deleted 85/84 750 3.2.00.03.v R

16X Human Factors Engineering Deleted 85/84 751 3.2.00.04 16A Human Factors Engineering 752 3.2.00.05 16A Human Factors Engineering 753 3.2.00.06.i R

16X Human Factors Engineering Deleted 85/84 754 3.2.00.06.ii R

16X Human Factors Engineering Deleted 85/84 755 3.2.00.06.iii R

16X Human Factors Engineering Deleted 85/84 756 3.2.00.07 16A Human Factors Engineering 757 3.2.00.08 16E Human Factors Engineering 758 3.2.00.09 16A Untargeted Human Factors Engineering Page 32 of 38

759 3.3.00.01 01A T

Buildings T

760 3.3.00.02a.i.a 01F T

Buildings Revised 167/165 T

761 3.3.00.02a.i.b 01F T

Buildings Revised 167/165 T

762 3.3.00.02a.i.c 01F T

Buildings Revised 167/165 T

763 3.3.00.02a.i.d 01F T

Buildings Revised 167/165 T

764 3.3.00.02a.ii.a 01A T

Buildings Deleted 167/165 760 765 3.3.00.02a.ii.b 01A T

Buildings Deleted 167/165 761 766 3.3.00.02a.ii.c 01A T

Buildings Deleted 167/165 762 767 3.3.00.02a.ii.d 01A T

Buildings Deleted 167/165 763 768 3.3.00.02a.ii.e 01A Buildings Revised 167/165 T

769 3.3.00.02a.ii.f 01A Buildings Revised 167/165 770 3.3.00.02b 01A T

Buildings T

771 3.3.00.02c R

11X Buildings Revised Deleted 30 85/84 772 3.3.00.02d R

11X Buildings Deleted 85/84 773 3.3.00.02e R

11X Buildings Deleted 85/84 774 3.3.00.02f 01A T

Buildings T

775 3.3.00.02g 11A T

Buildings Revised 147/146 T

776 3.3.00.02h 11A T

Buildings Revised 118/117 T

777 3.3.00.03a 01A T

Buildings Deleted 167/165 760 778 3.3.00.03b 01A T

Buildings Deleted 167/165 761 779 3.3.00.03c 01A T

Buildings Deleted 167/165 762 780 3.3.00.03d 01A T

Buildings Deleted 167/165 763 781 3.3.00.04a 01A T

Buildings Deleted 167/165 768 782 3.3.00.04b 01A T

Buildings Revised Revised 73/72 167/165 T

Page 33 of 38

783 3.3.00.04c 01A Buildings Deleted 73/72 784 3.3.00.05a 02C T

Buildings T

785 3.3.00.05b 01F T

Buildings T

786 3.3.00.05c 01F T

Buildings Revised Revised 23 30 T

787 3.3.00.06a 01F Buildings 788 3.3.00.06b 01A Buildings Revised 73/72 789 3.3.00.07aa 09A T

Buildings Revised 97/96 T

790 3.3.00.07ab 09A T

Buildings Revised 97/96 T

791 3.3.00.07ac 09A T

Buildings Revised 97/96 T

792 3.3.00.07ba 09A T

Buildings Revised 97/96 T

793 3.3.00.07bb 09A T

Buildings Revised 97/96 T

794 3.3.00.07bc 09A T

Buildings Revised 97/96 T

795 3.3.00.07c.i.a 09A T

Buildings Revised 97/96 T

796 3.3.00.07c.i.b 09A T

Buildings Revised 97/96 T

797 3.3.00.07c.ii.a 15A T

Buildings T

798 3.3.00.07c.ii.b 15A T

Buildings T

799 3.3.00.07d.i 09A T

Buildings Revised Revised Revised 88/87 97/96 112/111 T

800 3.3.00.07d.ii.a 09A T

Buildings Revised Revised Revised Revised 23 88/87 97/96 112/111 T

801 3.3.00.07d.ii.b 09A T

Buildings Revised Revised Revised Revised 23 88/87 97/96 112/111 T

802 3.3.00.07d.ii.c 09A T

Buildings Revised Revised Revised Revised 23 88/87 97/96 112/111 T

803 3.3.00.07d.iii.a 09A T

Buildings Revised 97/96 T

804 3.3.00.07d.iii.b 09A T

Buildings Revised 97/96 T

805 3.3.00.07d.iii.c 09A T

Buildings Revised 97/96 T

Page 34 of 38

806 3.3.00.07d.iv.a 09A T

Buildings Revised 97/96 T

807 3.3.00.07d.iv.b 09A T

Buildings Revised 97/96 T

808 3.3.00.07d.iv.c 09A T

Buildings Revised 97/96 T

809 3.3.00.07d.v.a 09A T

Buildings Revised 97/96 T

810 3.3.00.07d.v.b 09A T

Buildings Revised 97/96 T

811 3.3.00.07d.v.c 09A T

Buildings Revised 97/96 T

812 3.3.00.07e 09A T

Buildings T

813 3.3.00.08 04F T

Buildings T

814 3.3.00.09 01A T

Buildings T

815 3.3.00.10.i 06D T

Buildings T

816 3.3.00.10.ii 06D T

Buildings Revised 113/112 T

817 3.3.00.10.iii 06F T

Buildings Deleted 113/112 816 818 3.3.00.12 01A Buildings 819 3.3.00.13 01A T

Buildings Revised 127/126 T

820 3.3.00.14 17E T

Buildings T

821 3.3.00.16 17A T

Buildings T

822 3.3.00.17 17A T

Buildings T

823 3.5.00.01.i 19A Radiation Monitoring System Revised 85/84 T

824 3.5.00.01.ii 19E T

Radiation Monitoring System Deleted 85/84 823 825 3.5.00.01.iii 19F T

Radiation Monitoring System Deleted 85/84 823 826 3.5.00.02.i 08E Radiation Monitoring System Deleted 85/84 823 827 3.5.00.02.ii 09F Radiation Monitoring System Deleted 85/84 823 828 3.5.00.03 R

09X Radiation Monitoring System Deleted 85/84 829 3.5.00.04 10A Radiation Monitoring System Deleted 113/112 831 Page 35 of 38

830 3.5.00.05 19A Radiation Monitoring System Deleted 113/112 831 831 3.5.00.06 19A Untargeted Radiation Monitoring System Revised 113/112 832 3.5.00.07 19A Radiation Monitoring System Deleted 113/112 831 833 3.5.00.08 19A Radiation Monitoring System Deleted 113/112 831 834 3.6.00.01.i R

10X Reactor Coolant System Leak Detection System Deleted 85/84 835 3.6.00.01.ii R

10X Reactor Coolant System Leak Detection System Deleted 85/84 836 3.6.00.01.iii R

10X Reactor Coolant System Leak Detection System Deleted 85/84 837 3.6.00.01.iv R

10X Reactor Coolant System Leak Detection System Deleted 85/84 838 3.6.00.01.v R

10X Reactor Coolant System Leak Detection System Deleted 85/84 839 3.6.00.01.vi R

10X Reactor Coolant System Leak Detection System Deleted 85/84 840 3.6.00.01.vii R

10X Reactor Coolant System Leak Detection System Deleted 85/84 841 3.7.00.01 16F T

Design Reliability Assurance Program T

842 C.3.8.01.01 03F T

Piping Rupture Hazard Analysis T

843 C.3.8.02.01 03F T

Piping Design T

844 E.3.8..05.01.0 1 02C T

Waterproof Membrane T

845 E.3.9.01.01.01 18A Untargeted Emergency Classification System Revised Revised 24 74/73 846 E.3.9.01.01.02 18F Emergency Classification System Deleted 24 847 E.3.9.03.00.01 18D Untargeted Emergency Communications Revised 95/94 848 E.3.9.03.00.02 18D Untargeted Emergency Communications Revised 95/94 849 E.3.9.05.01.01 18A T

Emergency Facilities and Equipment T

Deleted on Unit 4 850 E.3.9.05.01.02 18D Emergency Facilities and Equipment Deleted 95/94 851 E.3.9.05.01.03 18D Untargeted Emergency Facilities and Equipment Revised U3 Deleted 24 163 Deleted on Unit 3 852 E.3.9.05.01.04 18A Untargeted Emergency Facilities and Equipment 158 853 E.3.9.05.01.05 18A T

Emergency Facilities and Equipment U3 Revised U4 Deleted 24 T

Deleted on Unit 4 Page 36 of 38

854 E.3.9.05.01.06 18A Emergency Facilities and Equipment Deleted 163/161 855 E.3.9.05.01.07 18D T

Emergency Facilities and Equipment T

Deleted on Unit 4 856 E.3.9.05.01.08 18D Untargeted Emergency Facilities and Equipment Deleted on Unit 4 857 E.3.9.05.02.01 18D Emergency Facilities and Equipment Deleted 95/94 858 E.3.9.05.02.02 18D Untargeted Emergency Facilities and Equipment Revised Deleted 24 163 Deleted on Unit 3 859 E.3.9.06.00.01 18D Accident Assessment Revised Revised Deleted 24 74/73 95/94 860 E.3.9.06.00.02 18F Accident Assessment Revised Deleted 95/94 163/161 861 E.3.9.06.00.03 18F Accident Assessment Revised Deleted 95/94 163/161 862 E.3.9.06.00.04 18D Untargeted Accident Assessment 863 E.3.9.06.00.05 18D Accident Assessment Revised Deleted 95/94 163/161 864 E.3.9.06.00.06 18D Accident Assessment Revised Deleted 95/94 163/161 865 E.3.9.07.01.01 18D Protective Response Deleted 95/94 866 E.3.9.07.01.02 18D Untargeted Protective Response Revised Revised 24 95/94 867 E.3.9.07.01.03 18D Protective Response Deleted 95/94 868 E.3.9.07.01.04 18D Protective Response Deleted 24 95/94 869 E.3.9.07.01.05 18D Protective Response Deleted 95/94 870 E.3.9.08.01.01 18D T

Exercises and Drills Revised Revised U4 Deleted 74/73 95/94 161 T

Deleted on Unit 4 871 E.3.9.08.01.02 18D Untargeted Exercises and Drills Revised Revised U4 Deleted 74/73 95/94 161 Deleted on Unit 4 872 E.3.9.08.01.03 18D T

Exercises and Drills Revised U4 Deleted 95/94 161 T

Deleted on Unit 4 873 E.3.9.09.00.01 18F Implementing Procedures Deleted 163/161 874 E.2.5.04.05.05.01 01C T

Backfill Material T

875 E.2.5.04.05.05.02 01C T

Backfill Shear Wave Velocity T

876 2.6.03.04j 08E T

Class 1E DC &

Uninterruptible Power Supply System Added 69/68 T

877 2.2.05.09c 08C T

Main Control Room Emergency Habitability System Added 108/107 T

Page 37 of 38

878 2.3.10.11a 10C Liquid Radwaste System Added 107/106 879 2.3.10.12 10A Liquid Radwaste System Added 107/106 880 2.2.05.07e 19A T

VES Filter Shielding Added 123/122 T

881 2.3.07.07b.vii 6A Volume cask loading pit Added 126/125 Page 38 of 38