1 Miller, Ed From:
Miller, Ed Sent:
Friday, January 10, 2020 7:41 AM To:
Miller, Ed
Subject:
Material for 1/16/2020 Public Meeting - Anders Presentation Attachments:
Anders-presentation-publicmeetinh-1-16-20.pdf Attached is the subject presentation material for the Jan 16, 2020, public meeting.
Status Update:
Regulatory Guide 1.200 Anders Gilbertson Office of Nuclear Regulatory Research Anders.Gilbertson@nrc.gov, 301-415-1541 January 16, 2020
OVERVIEW
- Status of Regulatory Guide (RG) 1.200
- Proposed changes to RG 1.200 for Revision 3
- Planned Path forward 2
RG 1.200, Status Update January 16, 2020 Public Meeting
Status of RG 1.200 (1 of 2)
- Revision 3 being prepared for publication as a draft RG
- Has been in development for about 2 years; staff position has been informed by
- multiple public meetings
- observation of pilots for new peer review guidance and consensus standard requirements
- participation in Owners Group workshops
- Public meetings have been conducted on RG 1.200, Revision 3 to:
- share the staffs draft work product
- solicit input from external stakeholders on proposed changes 3
RG 1.200, Status Update January 16, 2020 Public Meeting
Status of RG 1.200 (2 of 2)
- Next edition of the ASME/ANS Level 1/LERF PRA standard
- ASME/ANS Level 2 PRA standard 4
RG 1.200, Status Update January 16, 2020 Public Meeting
Proposed Changes to RG 1.200 (1 of 4)
- Changes are intended to provide additional clarity, improve process efficiency, and enhance safety
- Proposed changes include:
- New staff endorsements
- Enhancements/clarifications to guidance
- Updates related to organization of RG content 5
RG 1.200, Status Update January 16, 2020 Public Meeting
Proposed Changes to RG 1.200 (2 of 4)
NRC staff endorsements:
- NEI 17-07, Revision 21
- Appendix X - F&O independent assessment process
- NDM peer review requirements
- ASME/ANS RA-S Case 1 for seismic PRA2
- PWROG-19027-NP, Revision 13
- requirements for peer review of newly developed methods (Sections 4 and 5)
Endorsements include consideration of comments from internal and external stakeholders (e.g., public, ACRS, NRC/OGC, etc.)
1 See Agencywide Document Access and Management System (ADAMS) accession No. ML19241A615 2 Available via http://www.asme.org 3 See ADAMS accession No. MLXXXXXXXXX 6
RG 1.200, Status Update January 16, 2020 Public Meeting
Proposed Changes to RG 1.200 (3 of 4)
- Enhancements/clarifications to guidance:
- Key assumptions and sources of uncertainty
- Risk-informed decisionmaking
- Glossary of terms
- Listing of hazards
- Incorporates resolution of DPO-2016-0014
- Updates related to organization of content:
- Reorganization of Sections A and B 4 See ADAMS accession No. ML17013A015 7
RG 1.200, Status Update January 16, 2020 Public Meeting
Proposed Changes to RG 1.200 (4 of 4)
- Sections A and B - Reorganized and includes discussion on PRA acceptability
- Section C.1 - Minor revisions, reorganized for clarity
- Section C.2 - Revised to expand staff position and include related new endorsements
- Section C.3 - Minor revisions related to key assumptions and sources of uncertainty
- Section C.4 - Revised to reflect changes in Section C.2
- Added glossary of terms
- New appendices for endorsements 8
RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Sections A and B
- Reorganized for clarity
- Discussion on PRA acceptability added consistent with resolution of DPO-2016-001
- Provides current status of PRA standards efforts 9
RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.1
- Revised to provide clarity and consistent language
- Subsections on PRA technical elements arranged consistent with Parts in the ASME/ANS Level 1/LERF PRA standard
- Staff position on low-power and shutdown PRA moved into separate subsection in C.1 10 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.2
- Revised for clarity
- Includes language related to ASME/ANS RA-S Case 1 for seismic PRA 11 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.2.1
- Includes language regarding PRA state of practice and peer review of a newly developed method 12 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.2.2
- Includes language related to the peer review of newly developed methods
- Divided into three main subsections:
2.2.1 Peer Review of a Base PRA Model 2.2.2 Peer Review of a PRA Upgrade or Newly Developed Method 2.2.2.1 Peer Review of a PRA Upgrade 2.2.2.2 Peer Review of a Newly Developed Method 2.2.3 Facts and Observation Independent Assessment 13 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.2.2.1
- Includes added language on the peer review process, team qualifications, and documentation, consistent with NEI 17-07, Revision 2 14 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.2.2.2
- References Appendix C, which endorses process in PWROG-19027-NP, Revision 1 15 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.2.2.2.1
- Defines PRA upgrade
- Endorses requirements in PWROG-19027-NP, Revision 1, related to focused-scope peer review 16 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.2.2.2.2
- Defines newly developed method and provides guidance on a peer review thereof
- Endorses requirements in PWROG-19027-NP, Revision 1, for the peer review of a newly developed method; includes documentation requirements and expectations on the outcome of such peer reviews 17 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.2.2.3
- Endorses NEI 17-07, Revision 2, guidance on Facts and Observations (F&O) Independent Assessments.
- Guidance is consistent with the staff position documented in the NRC letter5 on the NEI Appendix X to NEI 00-02, NEI 05-04, and NEI 07-12
- Provides overall endorsement of NEI 17-07, Revision 2, as a means of satisfying the peer review requirements in ASME/ANS RA-Sa-2009 5 See ADAMS accession No. ML17079A427 18 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.3
- Provides clarifications regarding key assumptions and sources of uncertainty 19 RG 1.200, Status Update January 16, 2020 Public Meeting
Revisions to Section C.4
- Revised to include documentation requirements related to a PRA upgrade, the use of newly developed method, and F&O independent assessments 20 RG 1.200, Status Update January 16, 2020 Public Meeting
New Glossary of Terms as-built, as-operated as-designed, as-to-be-built, as-to-be-operated assumption key assumption base PRA consensus method/model conservative current good practice (or state-of-practice) key assumption key source of uncertainty level of detail model*
newly developed method*
PRA PRA acceptability PRA maintenance*
realism risk significance significant accident sequence significant basic event/contributor 21
- These terms and their definitions have been adopted from PWROG-19027-NP, Revision 1 RG 1.200, Status Update January 16, 2020 Public Meeting
New Appendices (1 of 2)
- Appendix A: Endorsement of ASME/ANS RA-Sa-2009, unchanged from RG 1.200, Revision 2
- Appendix B: Endorsement of ASME/ANS RA-S Case 1, Case for ASME/ANS RA-Sb-2013 Standard for Level 1/Large Early Release Frequency Probabilistic Risk Assessment of Nuclear Power Plant Applications 22 RG 1.200, Status Update January 16, 2020 Public Meeting
New Appendices (2 of 2)
- Appendix D: Other Hazards 23 RG 1.200, Status Update January 16, 2020 Public Meeting
Planned Path Forward
- January 2020 - Public meeting to share draft
- February 2020 - ACRS Subcommittee Briefing
- NEI 17-07, Revision 2, and PWROG-19027-NP, Revision 1, to be revised to incorporate stakeholder comments 24 RG 1.200, Status Update January 16, 2020 Public Meeting