POWER AUTHORITY OF THE STATE OF NEW YORK 10 CoLUMeus CIRCLE NEW YonK. N. Y. too19 (212) 397 6200 osonart.sanny

"" [,,."[ * *

.""'.CIi. F,'c.

"" *ge' ,N.

e asunos c.imoatts

..g.,.,,,,. o,,go,.,

vie, e. -..

JOSEP.H.n. SCM. M I E.D En 1s curtv vic nossar i. witcour' May 13, 1981

",',,*A"," *"'

Pacornicic n. cunc JPN-81-35 canov w.

iucui,
'c",$",1,,f."!:'*'"'

OFFIC..

'" ".^.'. "o; ?"."..F.......,

.......u

....u Director of Nuclear Reactor Regulation United States Nuclear Regulatory Commission

,e-f'

?i[f s Washington, D. C.

20555 n-f s

Attention:

Mr. Thomas A. Ippolito

/[7 *g*= L h'

[1 Operating Reactors Branch No. 2 3

/

~

l.My y O ISSI:m.

Division of Licensing C

Subject:

James A. FitzPatrick Nuclear Power Plant u's M jrg u g

BWR Scram Discharge System - Long Term

- (y/. '

Modifications Docket No. 50-333

/

References:

(1) Letter T. A.

Ippolito (NRC) to G.T. Berry l

(PASNY) dated April 30, 1981; same subject.

l (2) Letter J.P. Bayne (PASNY) to T.A.

Ippolito (NRC) dated December 16, 1980 (3) NRC Staff Safety Evaluation Report (SER) on BWR Scram Discharge System dated December 1, 1980

Dear Sir:

This letter responds to your letter of April 30, 1981 on the same subject (Reference 1).

The Authority is currently involved in efforts to implement long-term modifications to James A. FitzPatrick Scram Discharge Syst;ms, as described in our letter of December 16, 1980 (Reference 2).

In addition to the provisions indicated therein, l

redundant scram discharge system instrumentation will be pro-vided with diversity utilizing the guidelines of safety criteria 3 of Reference 3, as amended.

Very truly yours, Nk g

I J.

P.

Bayne f

Senior Vice President C

Nuclear Generation 810s:90955

-