Louisiana Energy Services, LLC - Semi-Annual Radiological Effluent Release Report for January 1, 2019 Through June 30, 2019
ML19246A103
Person / Time
Site: 07003103
Issue date: 08/27/2019
From: Cowne S
Louisiana Energy Services, URENCO USA
To:
Office of Nuclear Material Safety and Safeguards
References
LES-19-130-NRC
Download: ML19246A103 (10)


Text

LES-19-130-NRC AUG 2 7 2019 USA ATIN: Document Control Desk Director The National Enrichment Facility Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Louisiana Energy Services, LLC NRC Docket No. 70-3103

Subject:

Semi-Annual Radiological Effluent Release Report for January 1, 2019 through June 30, 2019 Pursuant to 10 CFR 70.59, Louisiana Energy Services, LLC, also dba URE NCO USA, herewith submits the subject report. Enclosure 1 specifies the quantities released of licensed principal radionuclides in liquid or gaseous form, to uncontrolled areas.

Should there be any questions concerning this submittal, please contact Rick Medina, Acting Licensing and Performance Assessment Manager, at 575.394.5846.

Respectfully, phen Cowne ief Nuclear Officer and Compliance Manager

Enclosure:

1. Semi-Annual Radiological Effluent Release Report for January 1, 2019 through June 30, 2019 I

Louisiana Energy Services, LLC UUSA I P.O. Box 1789 I Eunice I New Mexico 188231 I USA T: +1 (575) 394 4646 I W: www.uusa.urenco.com rE4g

/J f<.-1'55 ZD

/i)J1SS

LES-19-130-NRC ENCLOSURE 1 Semi-Annual Radiological Effluent Release Report for January 1, 2019 through June 30, 2019

URENCO USA: Report of Radioactivity in Effluents: Liquid & Air: January 2019 - June 2019 There were no releases to the public during the reporting period that exceeded regulatory requirements, and detected isotopic uranium activities were comparable to pre-operational activities. No dose assessment was performed because the maximum potential dose directly at the point of gaseous and liquid effluent discharge points were acceptable. The potential maximum doses directly at the discharge points for both liquid and gaseous effluent were shown to be less than 10% of the radionuclide concentration dose.

In liquid effluent, the concentrations of isotopic uranium were either below the Minimum Detectable Concentration (MDC) or less than 10% of values listed in 10 CFR 20, Appendix B, Table 3, "Releases to Sewers" (Table 1-1 ).

In gaseous effluent, the gross uranium activity was either below the Minimum Detectable Activity (MDA) or less than 10% of values listed in 10 CFR 20, Appendix B, Table 2, "Effluent Concentrations - Class D Air" for U234, U235, and U238.

The concentrations of isotopic uranium in gaseous effluent was either below the Minimum Detectable Concentration (MDC) or less than 10% of values listed in 10 CFR 20.1301, 10 CFR 20.1302, and 10 CFR 20.1101 (d), as described in NRC Regulatory Guide 4.20 "Constraint on Releases of Airborne Radioactive Materials to the Environment for Licensees other than Power Reactors" dated December 1996.

LIST OF TABLES Table No.

1-1 1-2 1-3 1-4 1-5 1-6 1-7 USA The National Ennchrnent Fac1hty Title Lift Station 1 Wastewater Effluent - Radionuclides Quarters 1 & 2, 2019 Separations Building Module-1001 (SBM 1001) Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1MA1 & 1001-562-1MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 1 & 2, 2019 Separations Building Module-1003 (SBM 1003) Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1MA1 & 1003-562-1MA2-Gross Alpha & Gross Beta, and Radionuclides Quarters 1 & 2, 2019 Separations Building Module-1005 (SBM 1005) Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 & 1005-562-1MA2 -Gross Alpha & Gross Beta, and Radionuclides Quarters 1 & 2, 2019 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA 1 & 1100-562-1 MA2 - Gross Alpha &

Gross Beta, and Radionuclides Quarters 1 & 2, 2019 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA 1 & 1100-562-2MA2 - Gross Alpha &

Gross Beta, and Radionuclides Quarters 1 & 2, 2019 Centrifuge Test and Post Mortem Facilities-1300 (CTPMF) Exhaust Filtration System Gaseous Effluent - 1300-562-1 MA 1 Gross Alpha & Gross Beta, and Radionuclides Quarters 1, 2019

TABLE 1-1 Lift Station 1 Wastewater Effluent - Radionuclides,. Quarters 1 & 2, 2019 URENCO USA Lea County, New Mexico Lift Station 1 Wastewater Effluent-Radionuclide*

Sample Date Sample Total Results Counting Total Quantity

% of Table 3 of Appendix B to Radionuclide Time Uncertainty Flow*

Released 10 CFR 20 Values-Monthly (Date/Time)

Period (days)

(µCi/ml)

(µCi/ml)

(gal/day)

(Ci)

Average Release to Sewers Lift Station 1 - January - June 2019 Uranium - 233/234 2.20E-10 4.00E-11 13,000 1.95E-06 0.007%

Uranium - 235/236 4/9/2019 01 /01/19 -

180 O.OOE+OO Result 9:50 06/30/19 O.OOE+OO 13,000 Below LLD Result Below LLD Uranium - 238 7.00E-11 2.00E-11 13,000 6.20E-07 0.002%

Lift Station 1 Duplicate - January - June 2019 Uranium - 233/234 1.60E-10 4.00E-11 13,000 1.42E-06 0.005%

Uranium - 235/236 4/9/2019 01/01/19 -

180 O.OOE+OO Result 9:50 06/30/19 O.OOE+OO 13,000 Below LLD Result Below LLD Uranium - 238 4.00E-11 2.00E-11 13,000 3.54E-07 0.001%

Notes:

1.
  • = Table 3.4-4 'Anticipated Normal Plant Water Consumption" from the Environmental Report, Rev. 19, lists "Total Personnel Water Use" as approximately 13,000 gallons per day.
2.

µCi/ml = microCuries per milliliter.

3.

Radionuclides analyzed using method EICHROM AC01 by Cardinal Laboratories of Hobbs, NM.

4.

Quantity released is calculated if the result equals or exceeds the LLD. Facility-required lower level of detection (LLD) is 3.09E-9 µCi/ml.

USA The National Enrichment Facility

TABLE 1-2 Separations Building Module-1001 (SBM 1001 ): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1 MA 1 & 1001-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 1 & 2, 2019 URENCO USA Lea County, New Mexico.

Sample ID 1001-562-1MA1 10015621MA1 010319 10015621MA1 020119 10015621MA1 030119 10015621MA1 040119 10015621MA1 050119 10015621MA1 060319 10015621MA1 010319 10015621MA1 020119 10015621MA1 030119 10015621MA1 040119 10015621MA1 050119 10015621MA1 060319 1001-562-1MA2 10015621MA2 010319 10015621MA2 020119 10015621MA2 030119 10015621 MA2 040119 10015621MA2 050119 10015621MA2 060319 10015621MA2 010319 10015621MA2 020119 10015621MA2 030119 10015621 MA2 040119 10015621 MA2 050119 10015621MA2 060319 Radionuclide (Isotopic Uranium (U))

1001-562-1 MA 1 U-233/234 U-235/236 1 Qtr.

U-238 U-233/234 U-235/236 2 Qtr.

U-238 1001-562-1MA2 U-233/234 U-235/236 1 Qtr.

U-238 U-233/234 U-235/236 2 Qtr U-238 Notes: None USA The Nahonal Ennchment Fac,hty Sample Date 02/01/19 03/01/19 04/01/19 05/01/19 06/03/1 9 07/01/19 02/01/19 03/01/19 04/01/19 05/01 /1 9 06/03/1 9 07/01 /19 02/01/19 03/01/19 04/01/19 05/01/19 06/03/19 07/01 /1 9 02/01/19 03/01/19 04/01/19 05/01 /1 9 06/03/1 9 07/01/19 Sample Date 4/1/2019 7/1/2019 4/1/2019 7/1/2019 Gross Sample Period Analyte Result

(µCi/mL) 1/3/19 - 2/1/19 2.41E-17 2/1/19 - 3/1/19 1.22E-16 3/1/19 - 4/1/19 Gross 4.83E-17 4/1/19 - 5/1/1 9 Alpha 1.33E-16 5/1 /1 9 - 6/3/1 9 1.21E-16 6/3/19 - 7/1/1 9 7.00E-17 1/3/19 - 2/1/19 4.18E-15 2/1/19 - 3/1/19 4.62E-15 3/1/19-4/1/19 Gross 5.87E-15 4/1/19 - 5/1/19 Beta 5.58E-15 5/1 /1 9 - 6/3/1 9 4.40E-15 6/3/1 9 - 7/1/1 9 3.82E-15 1/3/19 - 2/1/19

-2.99E-17 2/1/19 - 3/1/19 1.70E-16 3/1/19 - 4/1/19 Gross 9.53E-17 4/1 /19 - 5/1 /19 Alpha 1.80E-16 5/1 /19 - 6/3/19 1.14E-16 6/3/19 - 7/1 /19 6.44E-17 1/3/19 - 2/1/19 5.06E-15 2/1/19-3/1/19 3.81E-15 3/1/19-4/1/19 Gross 4.71E-15 4/1/19 - 5/1/1 9 Beta 6.67E-15 5/1 /1 9 - 6/3/1 9 5.62E-15 6/3/19 - 7/1/19 4.21E-15 Result 2oTPU Sample Period

(µCi/ml)

(µCi/mL) 1.60E-16 7.64E-17 1/3/19-4/1/19 2.16E-17 3.67E-17 2.12E-16 8.77E-17 2.46E-16 6.27E-17 4/1/19-7/1/19 4.65E-17 3.07E-17 1.68E-16 5.08E-17 2.17E-16 1.02E-16 1/3/19-4/1/19 1.54E-17 4.87E-17 1.54E-16 8.87E-17 2.81E-16 6.68E-17 4/1/19-7/1/19 3.54E-17 2.59E-1 7 2.64E-16 6.42E-17 MDA/

Inst. Unc.

Total Flow Quantity

% ofTable2 MDC Released Appendix B

(µCi/mL)

(µCi/mL)

(m3)

(Ci) 10CFR 20 1.63E-16 8.56E-08 4.69E+05

<MDA

<MDA 1.66E-16 8.56E-08 4.63E+05

<MDA

<MDA 1.48E-16 8.56E-08 4.98E+05

<MDA

<MDA 1.79E-16 9.91E-08 4.87E+05

<MDA

<MDA 1.62E-16 9.91 E-08 5.33E+05

<MDA

<MDA 1.87E-16 7.21E-08 4.66E+05

<MDA

<MDA 3.25E-15 1.73E-06 4.69E+05 1.96E-09 0.139%

3.32E-15 1.40E-06 4.63E+05 2.14E-09 0.154%

2.96E-15 1.70E-06 4.98E+05 2.92E-09 0.196%

4.05E-15 1.68E-06 4.87E+05 2.72E-09 0.186%

3.67E-15 1.62E-06 5.33E+05 2.35E-09 0.147%

4.24E-15 1.51 E-06 4.66E+05

<MDA

<MDA 1.43E-16 1.11E-10 4.66E+05

<MDA

<MDA 1.52E-16 1.0SE-07 4.69E+05 7.96E-11 0.006%

1.30E-16 8.56E-08 4.74E+05

<MDA

<MDA 1.64E-16 1.22E-07 4.93E+05 8.85E-11 0.006%

1.53E-16 9.91E-08 5.28E+05

<MDA

<MDA 1.72E-16 7.21 E-08 4.61E+05

<MDA

<MDA 2.86E-15 1.55E-06 4.66E+05 2.36E-09 0.169%

3.05E-15 1.36E-06 4.69E+05 1.78E-09 0.127%

2.59E-15 1.51E-06 4.74E+05 2.23E-09 0.157%

3.70E-15 1.82E-06 4.93E+05 3.29E-09 0.222%

3.47E-15 1.76E-06 5.28E+05 2.97E-09 0.187%

3.90E-15 1.57E-06 4.61E+05 1.94E-09 0.140%

1oTPU MDC Total Flow Quantity

% ofTable2

(µCi/ml)

(µCi/mL)

(m3)

Released Appendix B (Ci) 10CFR 20 7.72E-17 4.94E-17 0.00 0.01%

3.67E-17 6.47E-17 1.43E+06

<MDC

<MDC 8.90E-17 4.92E-17 0.00 0.01%

6.51E-17 2.64E-17 0.00 0.01 %

3.09E-17 3.15E-17 1.49E+06 0.00 0.00%

5.22E-17 2.26E-17 0.00 0.01 %

1.03E-16 7.58E-17 0.00 0.01%

4.87E-17 1.03E-16 1.41E+06

<MDC

<MDC 8.93E-17 8.58E-17 0.00 0.01%

6.97E-17 2.32E-17 0.00 0.01 %

2.61 E-17 2.60E-17 1.48E+06 0.00 0.00%

6.69E-17 2.10E-17 0.00 0.01%

TABLE 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA 1 &

1003-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 1 & 2, 2019 URENCO USA Lea County, New Mexico Sample Gross Sample ID Date Sample Period Analyte Result

(µCi/ml) 1003-562-1 MA1 10035621MA1 010319 06/03/19 1 /3/19 - 6/3/19 Gross O.OOE+OO 1 0035621 MA 1 060319 07/01/19 6/3/19 - 7/1/19 Alpha O.OOE+OO 10035621MA1 010319 06/03/19 1/3/19 - 6/3/19 Gross 7.32E-16 10035621 MA 1 060319 07/01 /19 6/3/19 - 7/1/19 Beta 4.69E-15 1003-562-1 MA2 10035621MA2 010319 06/03/19 1 /3/19 - 6/3/19 Gross

-5.38E-17 10035621MA2 060319 07/01/19 6/3/19 - 7/1/19 Alpha 2.49E-16 10035621MA2 010319 06/03/19 1 /3/19 - 6/3/19 Gross 3.18E-15 10035621 MA2 060319 07/01/19 6/3/19 - 7/1/19 Beta 2.76E-15 Radionuclide Sample Result 2oTPU Sample Period (Isotopic Uranium (U))

Date

(µCi/ml)

(µCi/ml) 1003-562-1MA1 U-233/234 1.31E-16 4.20E-17 U-235/236 2 Qtr.

7/1/2019 1/3/19-7/1/19 2.42E-17 2.01E-17 U-238 9.42E-17 3.47E-17 1003-562-1 MA2 U-233/234 3.95E-16 1.06E-16 U-235/236 2 Qtr 7/1/2019 1/3/19-7/1/19 7.16E-17 4.98E-17 U-238 3.46E-16 9.81 E-17 Notes:

1.

10035621 MA1 010319, filter was put on 01/03/19 and removed 06/03/19.

2.

10035621 MA2 010319, filter was put on 01/03/19 and removed 06/03/19.

3.

Redundant monitor out of operation 8/15/18 to 5/15/19 due to faulty pump.

USA The National Enrichment Fac1hty MDA/

Inst. Unc.

Total Flow Quantity MDC

(µCi/ml)

(m3)

Released

(µCi/ml)

(Ci) 2.57E-17 O.OOE+OO 2.50E+06

<MDA 1.35E-16 O.OOE+OO 4.31E+05

<MDA 5.15E-16 1.57E-06 2.50E+06 1.83E-09 2.70E-15 1.66E-06 4.31E+05 2.02E-09 1.24E-16 2.41E-10 1.36E+06

<MDA 1.46E-16 1.44E-07 4.71E+05 1.17E-10 2.48E-15 1.69E-06 1.36E+06 4.33E-09 2.91 E-15 1.44E-06 4.71E+05

<MDA 1oTPU MDC Total Flow Quantity Released

(µCi/ml)

(µCi/ml)

(m3)

(Ci) 4.30E-17 2.28E-17 0.00 2.02E-17 2.16E-17 2.93E+06 0.00 3.53E-17 1.62E-17 0.00 1.10E-16 3.64E-17 0.00 5.00E-17 4.77E-17 1.83E+06 0.00 1.01E-16 2.68E-17 0.00

%ofTable2 Appendix B 10CFR 20

<MDA

<MDA 0.024%

0.156%

<MDA 0.008%

0.106%

<MDA

% ofTable2 Appendix B 10CFR 20 0.00%

0.00%

0.00%

0.01 %

0.00%

0.01 %

TABLE 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1 MA1 &

1005-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 1 & 2, 2019 URENCO USA Lea County, New Mexico Sample ID 1005-562-1MA1 10055621MA1 010319 10055621MA1 020119 10055621MA1030119 10055621MA1 040119 10055621 MA 1 050119 10055621MA1 060319 10055621MA1 010319 10055621MA1 020119 10055621MA1 030119 10055621 MA 1 040119 10055621 MA 1 050119 10055621MA1 060319 1005-562-1MA2 10055621MA2 010319 10055621MA2 020119 10055621MA2 030119 10055621 MA2 040119 10055621 MA2 050119 10055621 MA2 060319 10055621MA2 010319 10055621MA2 020119 10055621MA2 030119 10055621 MA2 040119 10055621 MA2 050119 10055621 MA2 060319 Radionuclide (Isotopic Uranium (U))

1005-562-1 MA1 U-233/234 U-235/236 1 Qtr.

U-238 U-233/234 U-235/236 2 Qtr.

U-238 1005-562-1 MA2 U-233/234 U-235/236 1 Qtr.

U-238 U-233/234 U-235/236 2 Qtr U-238 Notes: None USA The Nalional Enrichment Fac,hty Sample Date Sample Period Analyte 02/01/19 1/3/19 - 2/1/19 03/01/19 2/1/19 - 311/19 04/01/19 3/1/19 - 4/1/19 Gross 05/01/19 4/1/19 - 5/1/19 Alpha 06/03/19 5/1 /19 - 6/3/19 07/01/19 6/3/19 - 7/1/19 02/01/19 1/3/19-2/1/19 03/01/19 2/1/19 - 3/1/19 04/01/19 3/1/19 - 4/1/19 Gross 05/01/19 4/1/19 - 5/1/19 Beta 06/03/19 5/1/19 - 6/3/19 07/01/19 6/3/19-7/1/19 02/01/19 1/3/19 - 2/1/19 03/01/19 2/1/19 - 311/19 04/01/19 3/1/19 - 4/1/19 Gross 05/01/19 4/1/19 - 5/1/19 Alpha 06/03/19 5/1 /19 - 6/3/19 07/01/19 6/3/19 - 7/1/19 02/01/19 1/3/19 - 2/1/19 03/01/19 2/1/19 - 311/19 04/01/19 3/1 /19 - 4/1/19 Gross 05/01/19 4/1/19-5/1/19 Beta 06/03/19 5/1/19 - 6/3/19 07/01/19 6/3/19-7/1/19 Sample Result Date Sample Period

(µCi/ml) 1.67E-16 4/1/2019 1/3/19 - 4/1/19 2.02E-17 1.45E-16 2.65E-16 7/1/2019 4/1/19 - 7/1/19 3.63E-17 2.67E-16 2.52E-16 4/1/2019 1/3/19 - 4/1/19 5.86E-17 1.72E-16 2.01E-16 7/1/2019 4/1/19 - 7/1/19 4.54E-17 2.04E-16 Gross MDA/

Inst. Unc.

Total Flow Quantity Result MDC

(µCi/ml)

(m3)

Released

(µCi/ml)

(µCi/ml)

(Ci)

O.OOE+OO 1.66E-16 O.OOE+OO 8.60E+05

<MDA 2.63E-16 1.76E-16 1.22E-07 7.98E+05 2.10E-10 O.OOE+OO 1.63E-16 0.00E+OO 8.87E+05

<MDA 7.37E-17 1.97E-16 7.21E-08 8.33E+05

<MDA 6.74E-17 1.BOE-16 7.21 E-08 9.13E+05

<MDA 7.84E-17 2.10E-16 7.21 E-08 7.79E+05

<MDA 4.47E-15 3.32E-15 1.31E-06 8.60E+05 3.84E-09 4.99E-15 3.52E-15 1.33E-06 7.98E+05 3.98E-09 6.00E-15 3.25E-15 1.45E-06 8.87E+05 5.32E-09 5.09E-15 4.47E-15 1.59E-06 8.33E+05 4.24E-09 3.19E-15 4.0BE-15 1.46E-06 9.13E+05

<MDA 4.57E-15 4.75E-15 1.53E-06 7.79E+05

<MDA 1.30E-16 1.77E-16 8.56E-08 8.60E+05

<MDA 1.34E-16 1.82E-16 8.56E-08 7.98E+05

<MDA 6.82E-17 1.79E-16 6.31E-08 8.95E+05

<MDA 8.06E-17 2.16E-16 7.21E-08 8.44E+05

<MDA 7.39E-17 1.98E-16 7.21E-08 9.19E+05

<MDA 2.58E-16 2.35E-16 1.22E-07 7.77E+05 2.00E-10 7.53E-15 3.54E-15 1.53E-06 1.36E+06 1.02E-08 4.63E-15 3.64E-15 1.29E-06 4.71E+05 2.18E-09 6.11E-15 3.59E-15 1.41E-06 O.OOE+OO O.OOE+OO 6.74E-15 4.89E-15 1.68E-06 O.OOE+OO O.OOE+OO 4.03E-15 4.48E-15 1.51E-06 O.OOE+OO

<MDA 7.65E-15 5.32E-15 1.70E-06 O.OOE+OO O.OOE+OO 2aTPU 1aTPU MDC Total Flow Quantity

(µCi/ml)

(µCi/ml)

(µCi/ml)

(m3)

Released (Ci) 7.78E-17 7.87E-17 4.27E-17 0.00 3.0SE-17 3.0SE-17 4.60E-17 2.54E+06

<MDC 7.56E-17 7.63E-17 6.53E-17 0.00 7.61E-17 7.84E-17 2.65E-17 6.69E-10 3.01E-17 3.03E-17 2.60E-17 2.53E+06 0.00 7.65E-17 7.89E-17 3.01E-17 O.OOE+OO 9.19E-17 9.36E-17 5.22E-17 0.00 5.09E-17 5.11E-17 5.86E-17 2.55E+06 0.00 7.40E-17 7.50E-17 3.29E-17 0.00 6.64E-17 6.BOE-17 3.0BE-17 5.12E-10 3.57E-17 3.59E-17 3.BOE-17 2.54E+06 0.00 6.61 E-17 6.77E-17 2.14E-17 O.OOE+OO

%of Table 2 Appendix B 10CFR 20

<MDA 0.009%

<MDA

<MDA

<MDA

<MDA 0.149%

0.166%

0.200%

0.170%

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA 0.009%

0.251%

0.154%

0.204%

0.225%

<MDA 0.255%

% ofTable2 Appendix B 10CFR 20 0.01%

<MDC 0.00%

0.009%

0.00%

0.009%

0.01%

0.00%

0.01%

0.007%

0.00%

0.007%

TABLE 1-5 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA 1 &

1100-562-1 MA2, Gross Alpha & Beta, and Radionuclides: Quarters 1 & 2, 2019 URENCO USA Lea County, New Mexico Sample ID 1100-562-1 MA 1 11005621MA1 010319 11005621MA1 020119 11005621MA1 030119 11005621MA1 040119 11005621MA1 050119 11005621MA1 060319 11005621MA1 010319 11005621MA1 020119 11005621MA1 030119 11005621 MA 1 040119 11005621 MA 1 050119 11005621 MA1 060319 1100-562-1 MA2 11005621MA2 010319 11005621MA2 020119 11005621MA2 030119 11005621 MA2 040119 11005621 MA2 050119 11005621 MA2 060319 11005621MA2 010319 11005621MA2 020119 11005621MA2 030119 11005621 MA2 040119 11005621 MA2 050119 11005621 MA2 060319 Radionuclide (Isotopic Uranium (U))

1100-562-1MA1 U-233/234 U-235/236 1 Qtr.

U-238 U-233/234 U-235/236 2 Qtr.

U-238 1100-562-1MA2 U-233/234 U-235/236 1 Qtr.

U-238 U-233/234 U-235/236 2 Qtr U-238 Notes: None USA The National Ennchment Facrllty Sample Date 02/01/19 03/01/19 04/01/19 05/01/19 06/03/19 07/01/19 02/01/19 03/01/19 04/01/19 05/01/19 06/03/19 07/01/19 02/01/19 03/01/19 04/01/19 05/01/19 06/03/19 07/01/19 02/01/19 03/01/19 04/01/19 05/01/19 06/03/19 07/01/19 Sample Date 4/1/2019 7/1/2019 4/1/2019 7/1/2019 Gross Sample Period Analyte Result

(µCi/ml) 1/3/19-2/1/19 O.OOE+OO 2/1/19-3/1/19 7.37E-17 3/1/19 - 4/1/19 Gross O.OOE+OO 4/1/19 - 5/1/19 Alpha 2.20E-16 5/1 /19 - 6/3/19 2.65E-16 6/3/19 - 7/1/19 7.00E-16 1/3/19 - 2/1/19 6.89E-15 2/1/19-3/1/19 7.15E-15 3/1/19 - 4/1/19 Gross 8.22E-15 4/1/19 - 5/1/19 Beta 4.63E-15 5/1 /19 - 6/3/19 1.96E-15 6/3/19 - 7/1/19 5.09E-14 1/3/19 - 2/1/19 2.79E-16 2/1/19 - 3/1/19 7.08E-17 3/1/19 - 4/1/19 Gross 5.68E-17 4/1/19 - 5/1/19 Alpha O.OOE+OO 5/1 /19 - 6/3/19 2.25E-16 6/3/19 - 7/1/19 3.84E-16 1/3/19-2/1/19 6.88E-15 2/1/19 - 3/1/19 4.23E-15 3/1/19 - 4/1/19 Gross 5.30E-15 4/1 /19 - 5/1 /19 Beta 3.90E-15 5/1 /19 - 6/3/19 6.13E-15 6/3/19 - 7/1/19 5.20E-15 Result 2aTPU Sample Period

(µCi/ml)

(µCi/ml) 1.91E-16 8.65E-17 1/3/19 - 4/1/19 4.58E-17 4.71E-17 2.34E-16 9.11E-17 3.46E-16 9.09E-17 4/1/19-7/1/19 3.86E-17 3.31E-17 2.50E-16 7.63E-17 8.60E-17 1.47E-16 1/3/19 - 4/1/19 O.OOE+OO 1.00E-16 1.41E-16 1.30E-16 3.07E-16 9.62E-17 4/1/19-7/1/19 4.17E-17 3.82E-17 2.02E-16 7.76E-17 MDA/

Inst. Unc.

Total Flow Quantity

% of Table 2 MDC Released Appendix B

(µCi/ml)

(µCi/ml)

(m3)

(Ci) 10CFR 20 1.68E-16 0.00E+OO 4.58E+05

<MDA

<MDA 1.94E-16 6.31E-08 4.34E+05

<MDA

<MDA 1.61E-16 O.OOE+OO 6.43E+05

<MDA

<MDA 2.00E-16 1.22E-07 6.37E+05 1.40E-10 0.007%

1.80E-16 1.44E-07 7.04E+05 1.87E-10 0.009%

1.87E-15 7.21E-08 5.79E+05

<MDA

<MDA 3.35E-15 1.51E-06 4.58E+05 3.16E-09 0.230%

3.88E-15 1.45E-06 4.34E+05 3.10E-09 0.238%

3.22E-15 1.63E-06 6.43E+05 5.29E-09 0.274%

4.54E-15 1.55E-06 6.37E+05 2.95E-09 0.154%

4.08E-15 1.34E-06 7.04E+05

<MDA

<MDA 4.24E-14 1.62E-06 5.79E+05 2.94E-08 1.696%

1.87E-16 1.22E-07 2.62E+05 7.29E-11 0.009%

1.86E-16 6.31E-08 2.97E+05

<MDA

<MDA 1.50E-16 6.31E-08 6.35E+05

<MDA

<MDA 1.84E-16 O.OOE+OO 5.95E+05

<MDA

<MDA 2.05E-16 1.22E-07 2.41E+05 5.43E-11 0.008%

2.61 E-16 1.44E-07 O.OOE+OO O.OOE+OO 0.013%

3.73E-15 1.45E-06 2.62E+05 1.80E-09 0.229%

3.73E-15 1.24E-06 2.97E+05 1.26E-09 0.141%

2.99E-15 1.43E-06 6.35E+05 3.36E-09 0.177%

4.16E-15 1.60E-06 5.95E+05

<MDA

<MDA 4.64E-15 1.66E-06 2.41E+05 1.48E-09 0.204%

5.91E-15 1.58E-06 O.OOE+OO

<MDA

<MDA 1aTPU MDC Total Flow Quantity

% ofTable2

(µCi/ml)

(µCi/ml)

(m3)

Released Appendix B (Ci) 10CFR 20 8.76E-17 7.36E-17 0.00 0.01%

4.72E-17 5.97E-17 1.53E+06

<MDC

<MDC 9.26E-17 4.82E-17 0.00 0.01%

9.42E-17 2.64E-17 0.00 0.01%

3.32E-17 3.26E-17 1.92E+06 0.00 0.00%

7.83E-17 2.89E-17 0.00 0.01 %

1.47E-16 2.61E-16

<MDC

<MDC 1.00E-16 2.16E-16 1.19E+06

<MDC

<MDC 1.30E-16 1.22E-16 0.00 0.00%

9.87E-17 2.92E-17 0.00 0.01%

3.83E-17 3.60E-17 8.36E+05 0.00 0.00%

7.89E-17 4.18E-17 0.00 0.01 %

TABLE 1-6 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-2MA1 &

1100-562-2MA2, Gross Alpha & Beta, and Radionuclides: Quarters 1 & 2, 2019 URENCO USA Lea County, New Mexico Sample Gross Sample ID Sample Period Analyte Result Date

(µCl/ml) 1100-562-2MA1 11005622MA1 010319 04/01/19 1/3/19

  • 411/19 9.76E-16 11005622MA 1 040119 05/01/19 4/1 /19 - 5/1 /19 Gross 3.12E-16 11005622MA 1 050119 06/03/19 5/1 /19 - 6/3/19 Alpha 2.85E-16 11005622MA 1 060319 07/01/19 6/3/19 - 7/1/19 2.04E-16 11005622MA1 010319 04/01/19 1/3/19
  • 411/19 3.94E-15 11005622MA 1 040119 05/01/19 4/1/19 - 5/1/19 Gross 7.82E-15 11005622MA 1 050119 06/03/19 5/1 /19 - 6/3/19 Beta 5.03E-15 11005622MA 1 060319 07/01/19 6/3/19 - 7/1/19 4.54E-15 1100-562-2MA2 11005622MA2 010319 04/01/19 1/3/19 - 411/19 5.17E-16 11005622MA2 040119 05/01/19 4/1/19 - 5/1/19 Gross 2.79E-16 11005622MA2 050119 06/03/19 5/1/19 - 6/3/19 Alpha 1.67E-16 11005622MA2 060319 07/01/19 6/3/19 - 7/1/19 7.00E-17 11005622MA2 010319 04/01/19 1/3/19 - 411/19 2.59E-14 11005622MA2 040119 05/01/19 4/1/19 - 5/1/19 Gross 5.17E-15 11005622MA2 050119 06/03/19 5/1 /19 - 6/3/19 Beta 6.61E-15 11005622MA2 060319 07/01/19 6/3/19 - 7/1/19 6.36E-15 Radionuclide Sample Result 2oTPU Sample Period (Isotopic Uranium (U))

Date

(µCl/ml)

(µCi/ml) 1100-562-2MA 1 U-233/234 1.06E-15 1.95E-16 U-235/236 1 Qtr.

411/2019 1/3/19 - 411/19 4.85E-17 4.44E-17 U-238 4.71E-16 1.23E-16 U-233/234 2.77E-16 7.32E-17 U-235/236 2 Qtr.

7/1/2019 4/1/19 - 7/1/19 2.49E-17 2.37E-17 U-238 2.94E-16 7.53E-17 1100-562-2MA2 U-233/234 2.54E-15 1.0SE-15 U-235/236 1 Qtr.

4/1/2019 1/3/19 - 411/19 4.09E-16 5.35E-16 U-238 1.56E-15 8.49E-16 U-233/234 2.44E-16 6.56E-17 U-235/236 2 Qtr 7/1/2019 4/1/19 - 7/1/19 1.69E-17 1.93E-17 U-238 2.71E-16 6.87E-17 Notes:

1.

11005622MA1 010319, filter was put on 01/03/19 and removed 04/01/19.

2.

11005622MA2 010319, filter was put on 01/03/19 and removed 04/01/19.

3.

Redundant monitor out of operation 12/6/18 to 3/28/19 due to faulty pump.

USA The National Ennchment Facility MDA/

Inst. Unc.

Total Flow Quantity

% ofTable2 MDC Released Appendix B

(µCi/ml)

(µCi/ml)

(m3)

(Ci) 10CFR 20 5.08E-17 4.41E-07 7.93E+07 7.73E-08 0.033%

1.69E-16 1.58E-07 3.03E+07 9.45E-09 0.010%

1.54E-16 1.58E-07 3.29E+07 9.38E-09 0.009%

1.86E-16 1.22E-07 2.84E+07 5.79E-09 0.007%

1.02E-15 1.93E-06 7.93E+07 3.13E-07 0.131%

1.69E-16 1.89E-06 3.03E+07 2.37E-07 0.261%

1.54E-16 1.70E-06 3.29E+07 1.66E-07 0.168%

1.86E-16 1.57E-06 2.84E+07 1.29E-07 0.151%

7.03E-16 8.56E-08 6.88E+07

<MDA

<MDA 1.53E-16 1.76E-07 3.13E+07 8.73E-09 0.009%

1.52E-16 1.22E-07 3.43E+07 5.72E-09 0.006%

1.87E-16 7.21 E-08 2.95E+07

<MDA

<MDA 1.41E-14 1.45E-06 6.88E+07 1.79E-06 0.864%

3.47E-15 1.92E-06 3.13E+07 1.62E-07 0.172%

3.44E-15 1.86E-06 3.43E+07 2.27E-07 0.220%

4.24E-15 1.72E-06 2.95E+07 1.87E-07 0.212%

1aTPU MDC Total Flow Quantity

% ofTable2 Released Appendix B

(µCl/ml)

(µCl/ml)

(m3)

(Ci) 10CFR 20 2.09E-16 3.08E-17 8.37E-08 0.035%

4.45E-17 5.14E-17 7.93E+07

<MDC

<MDC 1.28E-16 4.63E-17 O.OOE+OO 0.016%

7.58E-17 2.85E-17 0.00 0.009%

2.37E-17 2.56E-17 9.16E+07

<MDC

<MDC 7.82E-17 2.58E-17 0.00 0.010%

1.10E-15 6.62E-16 1.75E-07 0.085%

5.36E-16 8.17E-16 6.88E+07

<MDC

<MDC 8.57E-16 6.58E-16 O.OOE+OO 0.052%

6.78E-17 3.06E-17 0.00 0.008%

1.93E-17 2.54E-17 9.51E+07

<MDC

<MDC 7.14E-17 2.21E-17 0.00 0.009%

TABLE 1-7 Centrifuge Test and Post Mortem Facilities-1300 (CTPMF): Local Extract Exhaust Gaseous Effluent Vent System, 1300-562-1 MA 1, Gross Alpha & Beta, and Radionuclides: Quarters 1, 2019 URENCO USA Lea County, New Mexico Sample Gross MDA/

Inst. Unc.

Sample ID Date Sample Period Analyte Result MDC

(µCi/ml)

(µCi/ml)

(µCi/ml) 1300-562-1 MA1 13005621MA1 010319 01 /30/19 1 /3/1 9-1 /30/19 Gross O.OOE+OO 1.61E-16 Alpha O.OOE+OO 13005621MA1 010319 01/30/19 1 /3/19-1 /30/19 Gross 6.40E-15 3.22E-15 1.49E-06 Beta Radionuclide Sample Result 2oTPU 1oTPU MDC Sample Period (Isotopic Uranium (U))

Date

(µCi/ml)

(µCi/ml)

(µCi/ml)

(µCi/ml) 1300-562-1MA1 U-233/234 3.55E-16 2.22E-16 2.23E-16 2.39E-16 U-235/236 1 Qtr.

1/30/19 1 /3/19-1 /30/19

-2.39E-17 7.28E-17 7.28E-17 1.98E-16 U-238 5.34E-16 2.47E-16 2.50E-16 1.18E-16 Notes:

1.

1300-562-1 MA1 monitor permanently shut down on 01 /30/2019. Building no longer in operation.

2.

Ci= Curies

3.

µCi/ml = micro-Curies per milliliter.

4.

m3 = cubic meters.

5.

MDA = minimum detectable activity.

6.

MDC= minimum detectable concentration.

7.

Quantity released is calculated if the result Equals or Exceeds MDA or MDC.

8.

Radionuclides analyzed using Procedure EPA 908.0 Modified by Eberline Analytical Corp of Oak Ridge, TN.

9.

Gross alpha and beta analyzed by URENCO USA per procedure EN-3-3030-01.

USA The National Ennchment Facility Total Flow Quantity

% ofTable2 (m3)

Released Appendix B (Ci) 10CFR 20 1.14E+07

<MDA

<MDA 1.14E+07 7.32E-08 0.213%

Total Flow Quantity

%of Table 2 Released Appendix B (m3)

(Ci) 10CFR 20 0.00 0.01 %

1.14E+07

<MDC

<MDC 0.00 0.02%