05000321/LER-1978-008-01, /01T-0 on 780209:during Steady State Power Operation,Test Valve Found to Be Broken Off.Cause Unknown. Valve Repaired.Investigation Under Way

From kanterella
(Redirected from ML19241A977)
Jump to navigation Jump to search
/01T-0 on 780209:during Steady State Power Operation,Test Valve Found to Be Broken Off.Cause Unknown. Valve Repaired.Investigation Under Way
ML19241A977
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 02/24/1978
From: Thomas Greene
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19241A968 List:
References
LER-78-008-01T, LER-78-8-1T, NUDOCS 7907110485
Download: ML19241A977 (2)


LER-1978-008, /01T-0 on 780209:during Steady State Power Operation,Test Valve Found to Be Broken Off.Cause Unknown. Valve Repaired.Investigation Under Way
Event date:
Report date:
3211978008R01 - NRC Website

text

.

. ~.,. _ _ _-___- -

w v.4 ma

~

e.mc FORn4 M4 U. S. NUCLE AR R f cut Af o4Y CoMM1131' (7 771 LICENSEE EVENT REPORT EXHIBIT coNTaot stoco 1 I l l l l l@

sett Ast paint on tvrt ALL atouinto is.eonwarion.i

@ lC l A l ElI l Hld..@ul 010 l Ol0 l 01 Of 01 O f 010! Ol@{ 013 l4 l 010 ;@l f l

,, s r u @

va.u.Ccc; m,a m..

a

,,u a,,..

con'T 8

E L.a_J@l01510'l O! 0l 3f 2 ! 1 @[ 0l 210 l 9l 7 l 8 @l 012 l 2 f 4 I 7 l 8 j@

L ei ooc......

.3 i, i., o..

is

.. oa, o.

tv(NT CISCAiPTION AND PRC8 ASLE CQa $(CVENCl3 QiO e

g lDuring steady state power operation, while preparing to perform a local lt eak rate test on an electrical penetration per Tech Spec. 4.7.A.2.e., a o 3

[ TIT)l test valve was found to be broken off.

This did not constitute a violata g of pri=ary containment integrity since sufficient isolation of the pri=ar-o e containment was =aintained.

8I t ola i l SvsTf ad CAwst caust C

vatvg Sv.OM 8 CODE COCf Se9Cc0E CoueONENT CCDE 00Cf susCacs I El Cl@ [Aj@ (XJ@ l P{ E l N jE f Tl R {@ [Dj@ Q @

o

,i io i,

i2 2

i.

n SEQUf wis AL OCCupathC1 me et,4 T

  • E V'SeO*.

@,'g,g e og

.(VENTvfA4 mtPCaf 40.

COCE Tvrt go jg,"l, 17l 81

[-j l 010 l 81 y

1011l LTJ

[, -J W

_m.

u u

2.

a n

u a

n'?.'. '.0"J c'.'I'f.'. r

'Wtr m ^,St&'!:'.c'W.

'" ",' 5,ca' o ff"lfn'.'.'t,

lAJ@LXJ@ L,ZJ@

LZJO I 01 olo gi I t

ou..

L.,NJ@

Lg@

[z_J@

L.Z l 9 19 i '

n u

2 a

v n

n CAvst ecsCairfics eNo CCnAECTIVE ACTICNS h FrT7] [The exact cause of the broken test valve is unknown; however, investigati, gis being =ade to determine the necessary recedial action to prevent re-g lcurrrence. Following discovery of the broken test valve, it was im=ediat(

g l repaired, local leak rate tested satisfactorily and left pressurized with Initrogen as specified.

7 STA w tPCwtm OTi.(R17ATUS SC Q m D'SCovf Rv 0t sCRDO*e [E_J@ [ 019 l 71@l N/A l if@[ Local Leak Rate Test i s

' C',iviry Cc'4re r

. ovar e,4Crivirv @ "

toCarmo..iteise@

=<uasro ca.ite se UT 1 [ zj @ Lzj@l N/A l

l N/A

...sc

'i i.,os " ri c.,C.,,,,0% @

l0}0l0l@ y @l N/A i i

' et.so s e't,

.t.2 as oi:C= 4 ric~ @

voit.

l 0 l 0l 0 l@l N/A h

i 9

.i is 6

W.', ' " ca".','e',* "" @

4 i

@ 113[__

N/A 4

,g I%

FTTl [ggg $[(5; pipy,CM O, N/ A ' '

1 I1l1IIti!I '

i a i m

ic,.,.

a **

Nava cs entranta Tom Croene. 4dprQ;of'MUL E n.:l,,M 5 'IR 36 7-7 7('l 9

w -. ;

,g c,

7907110

' W!O A [ N

.. o "

^]-

3,.

= m...

..-.a

....r.

O

NARRATIVE

REPORT LER 78 - 08 While preparing to perform a local leak rate test, per Tech Specs Section 4.7.A.-

2.e.,

on electrical penetration X-202, a technician discovered the valve used for testing or filling the penetration with nitrogen, broken. This resulted in the electrical penetration losing the nitrogen pressure that maintains an inert at-mosphere for the associated cables. This did not constitute a violation of primary containment integrity due to the redundancy of the recessed pressure headers in the penetra'. ion canister.

Penetration X-202 is a torus low voltage power penetration designed for power ap-plications up to 600 volts.

Following the discovery, the test valve was repaired and a local leak rate test was performed on the penetration with the results in-dicating zero leakage.

Investigation will be made to determine the necessity and extent of any further corrective action in an effort to preclude recurrence of this event and to deter-mine what, if any, cable degradation occurred due to the loss of nitrogen.

An update report will be submitted to document any further corrective action.

  • t f*

I '

=

O ff