Letter Sequence RAI |
|---|
EPID:L-2014-TOP-0004, Final Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Approved, Closed) TAC:MF3829, Final Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Approved, Closed) |
|
MONTHYEARML17356A2542017-05-25025 May 2017 Trip Report for May 16 to May 18, 2017, Audit in Support of the Review of Topical Report ANP-10332P (AURORA-B LOCA) (Non-Proprietary Version) Project stage: Other ML19095B7612017-10-24024 October 2017 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Request ML19095B7642017-10-24024 October 2017 Transmittal of Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 1, Non-Proprietar Project stage: RAI ML17356A2502018-01-10010 January 2018 NRC Staff Post-Acceptance Review Feedback and Questions, Areva'S Response Approach, and Subsequent NRC Staff Audit Comments for May 16 to May 18, 2017 Audit Supporting the Review of ANP-10332P (AURORA-B LOCA) Project stage: Acceptance Review ML17356A2472018-01-10010 January 2018 Audit Report for the May 16 to May 18, 2017 Audit in Support of the Review of ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-Proprietary Version) Project stage: Approval ML19095B7692018-01-19019 January 2018 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2) Project stage: Request ML19095B7702018-01-19019 January 2018 Transmittal of Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2, Non-Proprietar Project stage: RAI ML17360A2072018-01-19019 January 2018 Transmittal of Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: RAI ML19095B7732018-01-19019 January 2018 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2, Non-Proprietary) Project stage: RAI ML18122A2292018-04-30030 April 2018 Framatome, Inc., Response to Request for Additional Information Regarding Topical Report ANP-10332P, Revision 0, AURORA-8: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Response to RAI ML18122A2302018-04-30030 April 2018 ANP-10332Q1NP, Rev 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Responses to NRC Request for Additional Information Project stage: Response to RAI ML18171A3082018-07-17017 July 2018 Request for Withholding Information from Public Disclosure in April 30, 2018, Response to Request for Additional Information Regarding Topical Report ANP-10332P, Revision 0 (CAC No. MF3829; EPID L-2014-TOP-0004) Project stage: RAI ML18242A4262018-08-31031 August 2018 Draft Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios, (Non-Proprietary) Project stage: Draft Approval ML18323A5592018-12-18018 December 2018 Request for Withholding Information from Public Disclosure in October 31, 2018, Revised Response to Request for Additional Information Regarding Topical Report ANP-10332P, Revision 0 Project stage: RAI ML19052A5722019-03-26026 March 2019 Final Safety Evaluation for Framatome, Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-Proprietary Version) Project stage: Approval ML19057A5512019-03-26026 March 2019 Final Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Request ML19071A2952019-03-26026 March 2019 Resolution of Comments on Draft Safety Evaluation for Topical Report ANP-10332P, Revision 0 Project stage: Draft Approval ML19057A5552019-03-26026 March 2019 Transmittal of Final Safety Evaluation for Framatome Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios. Project stage: Approval ML19183A0102019-07-25025 July 2019 Verification Review Letter for Topical Report ANP-10332P-A, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Other 2018-12-18
[Table View] |
Text
January 19, 2018 Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome 3315 Old Forest Road Lynchburg, VA 24501
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING AREVA INC.
TOPICAL REPORT ANP-10332P, REVISION 0, AURORA-B: AN EVALUATION MODEL FOR BOILING WATER REACTORS; APPLICATION TO LOSS OF COOLANT ACCIDENT SCENARIOS (TAC NO. MF3829/EPID: L-2014-TOP-0004)
Dear Mr. Peters:
By letter dated March 25, 2014 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML14091A222), AREVA INC. (AREVA) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review and approval Topical Report ANP-10332P, Revision 0, AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios. Upon review of the information provided, the NRC staff has determined that additional information is needed to complete the review. On December 21, 2017, Alan Meginnis, AREVA Product Licensing Manager, and I agreed that the NRC staff will receive the response to the enclosed Request for Additional Information (RAI) questions within 6 months from the date of this letter.
If you have any questions regarding the enclosed RAI questions, please contact me at 301-415-4053.
Sincerely,
/RA/
Jonathan G. Rowley, Project Manager Licensing Processes Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project No. 728
Enclosure:
RAI Questions (Proprietary)
ML19095B770; RAI - ML19095B773; Package - ML19095B769;
- concurred via e-mail NRR-106 OFFICE PLPB/PM PLPB/LA* SNPB/BC PLPB/BC PLPB/PM NAME JRowley DHarrison RLukes DMorey JRowley DATE 1/11/18 1/9/18 1/17/18 1/18/18 1/19/18