March 12, 2019 Russell A. Bastyr Westinghouse Electric Company Vice President - Quality, Safety and Performance Improvement Nuclear Fuel and Component Manufacturing 5801 Bluff Road Columbia, SC 29209
SUBJECT:
WESTINGHOUSE ELECTRIC SWEDEN ABS RESPONSE TO THE U.S. NUCLEAR REGULATORY COMMISSION INSPECTION REPORT NO. 99901408/2018-201 AND NOTICE OF NONCONFORMANCE
Dear Mr. Bastyr:
Thank you for your January 2, 2019, and March 11, 2019, letters in response to the Notice of Nonconformance (NON) that was discussed in the subject U.S. Nuclear Regulatory Commission (NRC) inspection report (IR). We have reviewed your letter and found it to be responsive to the NON documented in IR 99901408/2018-201. We have no further questions or comments at this time and may review the implementation of your corrective actions during a future NRC staff inspection to determine whether full compliance has been achieved and maintained. Please contact Mr. Yamir Diaz-Castillo at 301-415-2228 or via electronic mail at Yamir.Diaz-Castillo@nrc.gov, if you have any questions or need assistance regarding this matter.
Sincerely,
/RA/
Kerri A. Kavanagh, Chief Quality Assurance Vendor Inspection Branches 1 and 2 Division of Construction Inspection and Operational Programs Office of New Reactors Docket No.: 99901408
ML19071A081 NRO-002 OFFICE NRO/DCIP NRO/DCIP NAME YDiaz-Castillo KKavanagh DATE 03/12/2019 03/12/2019