ML18257A051
| ML18257A051 | |
| Person / Time | |
|---|---|
| Site: | 99902041 |
| Issue date: | 09/21/2018 |
| From: | Rowley J NRC/NRR/DLP/PLPB |
| To: | Dennis Morey NRC/NRR/DLP/PLPB |
| Rowley J, NRR/DLP, 415-4053 | |
| References | |
| Download: ML18257A051 (3) | |
Text
September 21, 2018 MEMORANDUM TO: Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation FROM: Jonathan G. Rowley, Project Manager /RA/
Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF AUGUST 15, 2018, CLOSED MEETING WITH FRAMATOME INC. AND LIGHTBRIDGE CORPORATION TO INTRODUCE ENFISSION LLC On August 15, 2018, a closed meeting was held between the U.S. Nuclear Regulatory Commission (NRC) staff, Framatome Inc. (Framatome), and Lightbridge Corporation (Lightbridge) to introduce Enfission LLC (Enfission) to the NRC. In addition to the organization introduction, key elements of the Lightbridge Fuel design and project plans where discussed.
Enfission is a 50-50 joint venture of Lightbridge and Framatome. The Lightbridge fuel design is an accident tolerant fuel concept that utilizes an extruded, solid metallic, helically-twisted, four lobed fuel rod with uranium enrichment up to 19.7 percent. Enfission believes that there are many benefits (e.g., thermal hydraulic, mechanical, and operational) to the design over the currently used ceramic uranium oxide fuel pellets encapsulated in cylindrical zirconium cladding. Enfission plans to insert a lead test rod, a lead test assembly, and a batch reload in a commercial reactor at varying intervals in the future.
A list of attendees is enclosed. The Enfission presentation material can be found in the Agencywide Documents Access and Management System at Accession Nos. ML18232A127 (proprietary) and ML18232A126 (non-proprietary).
Docket No. 99902041
Enclosure:
List of Attendees CONTACT: Jonathan G. Rowley, DLP/PLPB (301) 415-4053
Summary - ML18257A051; Presentation - ML18232A127 (proprietary)/ML18232A126 (Non-proprietary) NRR-106 OFFICE NRR/DLP/PLPB/PM NRR/DLP/PLPB/BC NRR/DLPPLPB/PM NAME JRowley DMorey (HCruz for) JRowley DATE 9/14/2018 9/21/2018 9/21/2018 List of Attendees Enfission Introduction Meeting August 15, 2018 Name Organization James Malone Enfission LLC (Enfission)
Aaron Totemeier Enfission Nathan Hottle Enfission Jeff Tucker Enfission Jonathan Baggett Enfission James Fornof Lightbridge Corporation Jon Johnson Lightbridge Corporation Jonathan Rowley U.S. Nuclear Regulatory Commission (NRC)
Jacob Zimmerman NRC James Hammelman NRC Mirela Gavrilas NRC Andrew Proffitt NRC Ian Porter NRC Ricardo Torres NRC Kevin Ramsey NRC Johsua Whitman NRC Jane Marshall NRC Scott Krepel NRC MJ Ross-Lee NRC Robert Beaton NRC Paul Clifford NRC Robert Lukes NRC Jason Paige NRC Enclosure