ML18191B356

From kanterella
Jump to navigation Jump to search
COL Docs - Uin Comment Status Sheet for Future Public Meeting
ML18191B356
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 07/10/2018
From:
NRC
To:
NRC/NRO/DLSE/LB4
References
Download: ML18191B356 (3)


Text

1 Vogtle PEmails From:

Hoellman, Jordan Sent:

Tuesday, July 10, 2018 3:41 PM To:

Vogtle PEmails

Subject:

UIN Comment Status Sheet for Future Public Meeting Attachments:

UIN ICN comment status sheet July 12.docx Please see the attached UIN Comment Status Sheet for discussion at a future public meeting with SNC regarding licensing actions at Vogtle Units 3 and 4.

Hearing Identifier:

Vogtle_COL_Docs_Public Email Number:

318 Mail Envelope Properties (SN6PR09MB2608C732D6E376599B2A2B31D55B0)

Subject:

UIN Comment Status Sheet for Future Public Meeting Sent Date:

7/10/2018 3:41:01 PM Received Date:

7/10/2018 8:15:31 PM From:

Hoellman, Jordan Created By:

Jordan.Hoellman2@nrc.gov Recipients:

"Vogtle PEmails" <Vogtle.PEmails@nrc.gov>

Tracking Status: None Post Office:

SN6PR09MB2608.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 159 7/10/2018 8:15:31 PM UIN ICN comment status sheet July 12.docx 27987 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

1 VOGTLE ICN/UIN ISSUES TRACKING SHEET Date ITEM #

ICN UIN TOPIC ITAAC INDEX ISSUE Licensee Comment 7/12 1

UIN MOV Qual.

V3 /

V4

114, 154, 248, 248, 309, The determination basis should also include reference to production valve tests required by the ASME QME 2007.

7/12 2

UIN IDS Equip Quals and ratings V3 /

V4 616

1. Each ITAAC section should be uniquely identified throughout the document not just in the DC. See agreed on example UIN for consolidated ITAAC 2.3.06.02a (Index No. 355).
2. Completion description for #7 - clearly identify how the load requirements were established. How does the last sentence in 3rd paragraph apply with respect to the 4th paragraph?

6/7 3

UIN V3/V4 The Acceptance Criteria for ITAAC 2.6.09.08 (Index Number 650) states that The illumination in isolation zones and exterior areas within the protected area is 0.2 foot candles measured horizontally at ground level or, alternatively, sufficient to permit observation. This wording has been in the COL Appendix C ITAAC since version 1.0.

SNCs proposed plan is acceptable to the NRC staff.

SNC is preparing the UIN for ITAAC 2.6.09.08 to include a sentence similar to this: The Unit 3 (Unit

4) Inspection Report YYY confirms that the illumination in isolation zones and exterior areas within the protected area is a minimum of 0.2 foot candles measured horizontally at ground level or, alternatively, sufficient to permit observation of abnormal presence or activity of persons or vehicles utilizing low-light technologies.

7/11 4

UIN SNC position paper V3 /

V4 328 Functional vs functional capability