HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-42 With regard to past operations at the site involving an oil recovery facility with tanks within the CIS Facility Site boundary, it should be noted that there are no oil recovery operations presently occurring on the Site and none are reasonably foreseeable. There are 7 aboveground storage tanks (ASTs) associated with past brine disposal activities on the site. These ASTs are holding tanks that were used for storing brine and settling solids and separating residual oil from oil-field brines.
'The tanks range in size from 150 barrels to 250 barrels. These holding tanks or ASTs are not in use. No containers of hazardous substances have been noted in prior site visits (2007) or most recent site visits (2016). Within Section 13, which is where the CIS Facility would be located, two additional tanks (250 gallon barrels) are present at the well location in the southwest portion of the Site.
One active oil/gas well on the southwest portion of Section 13 operates at minimum production to maintain mineral rights.
2.2.3 Air Transportation The airspace surrounding the CIS Facility is unrestricted and at any given time there would be the potential for commercial aircraft, military aircraft, and civilian aircraft to be flying in that airspace at various altitudes and at various speeds. Commercial aircraft would fly in accordance with flight plans filed with the Federal Aviation Administration (FAA) and would be controlled by the national air traffic control system [2.2.5] [2.2.18]. Military aircraft would fly within designated Military Training Routes (MTRs), which may or may note be flown under air traffic control.
Commercial aircraft flight plans would be limited to the Federal Airways that make up the en route airspace structure of the National Airspace System. There are multiple federal airways near the CIS Facility: V83, V102, and V291 [2.2.16] [2.2.17]. Victor routes are low altitude airways that make up the majority of the lower stratum of the federal en route airspace structure. Victor routes extend from the floor of the controlled airspace up to but not including 18,000 feet above mean sea level [2.2.18]. They are defined as straight line segments between VOR stations and have a width of 4NM on either side of the centerline when VOR stations are less than 102 NM apart, with the width increasing for VORs farther apart [2.2.18]. Additional information for these airways, including their distances from the site, is included in Table 2.2.5. These federal airways are illustrated on Figure 2.2.6.
Because airspace above the United States from the surface to 10,000 feet above sea level is limited to 250 knots (indicated airspeed) by FAA regulations, any aircraft below 10,000 feet would be travelling at speeds of less than 250 knots. There is a military exception to this requirement, however. The Military Training Route Program is a joint venture by the FAA and the Department of Defense (DOD), developed for use by military aircraft to gain and maintain proficiency in tactical "low-level" flying. These low-level training routes are generally established below 10,000 feet for speeds in excess of 250 knots. Military Training Routes do not constitute an official airspace and are all open to civilian traffic [2.2.6].
MTRs are designated either IR (Instrument Route) or VR (Visual Route), with IR routes being flown under air traffic control [2.2.19]. Military training routes are usually limited to 420 knots, and in no case are aircraft allowed to exceed Mach 1 within United States sovereign airspace, except in designated Military Operation Areas. While on the route, military aircraft squawk a Mode C Transponder code of '4000', which informs controllers that they are 'speeding' on a route.
This squawk however is only legal by military aircraft, while inside a properly scheduled route corridor [2.2.20].
Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-43 There are four designated Military Training Routes in the vicinity of the proposed CIS Facility:
IR-128, IR-180, IR-192, and IR-194. However, these four designations represent only 2 mapped airways, as IR-128 and IR-180, and IR-192 and IR-194 share the same airway but represent opposite directions of travel (hereafter referred to as IR-128/180 and IR-192/194, respectively).
IR-128 and IR-192 both represent the North to South direction, while IR-180 and IR-194 represent the South to North flight direction of their respective corridors [2.2.19] [2.2.16]. The routes are individually operated by an Air Force Base, which schedule and 'own' the route. IR-128/180 is owned by Dyess AFB while IR-192/194 is owned by Holloman AFB. The FAA requires the military to provide advance notice to other aircraft that the Military Training Routes will be used to allow for civilian traffic to de-conflict if needed. Department of Defense publication AP/1B defines all MTRs giving coordinates of airway fixes, or points between segments as well as the airway width different points along the route. Additional information for these airways, including their distances from the site and widths, is included in Table 2.2.5. These Military Training Routes are also illustrated on Figure 2.2.6.
A Military Operation Area (MOA) is airspace established outside Class A airspace to separate or segregate certain nonhazardous military activities from IFR Traffic and to identify for VFR traffic where these activities are conducted." [2.2.21]. The nearest MOAs to the CIS facility are the Talon High East MOA, which is located north of Carlsbad, NM and the Bronco 3 MOA, which is located North of Hobbs, NM. The nearest edge of both of these MOAs is greater than 25 miles from the site.
As discussed below, most of the commercial airline operations at airports in the area of the CIS Facility involve regional jets. The largest commercial planes (Boeing 737s) are flown in and out of Midland International Air and Space. A summary of the airplane operations at airports near the CIS Facility are provided below. Airport operation numbers have been gathered from 2 sources, first is the Air Traffic Activity Data System (ATADS), which contains the official NAS air traffic operations data available for public release. The other is GRC Inc.s AirportIQ 5010, which is a compilation of FAA form 5010-5 Airport Master Records and Reports. ATADS gives data as far back as 1990, where AirportIQ gives only the past years data. Additionally, ATADS only gives data for Airports that have an FAA certified Air traffic control tower, so data for some of the smaller airports has only been sourced from AirportIQ.
Artesia Municipal Airport* is a public use general aviation airport located 4 miles west of the Main Street business district or Atresia, in Eddy County, New Mexico, approximately 47 miles from the CIS Facility. The city owned airport and its 2 runways covers 1,440 acres. For the 12 month period ending April 05, 2017 the airport had approximately 14,050 aircraft operations, an average of 38 per day: 82 percent general aviation, and 18 percent military. During this period, 30 aircraft were based at this airport: 26 single engine, and 4 multi engine [2.2.22].
- Note that Atresia Municipal Airport does not have an FAA funded air traffic control tower, and therefore does not have data reported to ATADS.
Cavern City Air Terminal* is a public use airport in Eddy County, New Mexico, United States. It is owned by the city of Carlsbad and located five miles southwest of its central business district, Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-44 approximately 34 miles from the CIS Facility. The airport is served by one commercial airline.
For the 12 month period ending December, 31, 2016, the airport had approximately 6,900 aircraft operations, an average of 19 per day: 53 percent general aviation, 4 percent air taxi, 39 percent air carrier, and 4 percent military. During this period, 22 aircraft were based at this airport: 15 single-engine, 2 multi-engine, 2 jet, 2 helicopter, and 1 ultra-light [2.2.23]. The approach pattern for Cavern City Air Terminal is approximately 14 miles North East of the airport, locating it a little more than 22 miles from the CIS Facility see Table 2.2.6 [2.2.30].
- Note that Cavern City Air Terminal does not have an FAA funded air traffic control tower, and therefore does not have data reported to ATADS.
Lea County Regional Airport* is 4 miles west of Hobbs in Lea County, NM, approximately 30 miles from the CIS Facility. The airport covers 898 acres and has three runways. It is an FAA certified commercial airport served by United Airlines' affiliate with daily regional flights. Lea County Regional Airport is the largest of the three airports owned and operated by Lea County Government. Lea County also owns and operated two general aviation airports in Lovington and Jal, New Mexico. For the 12-month period ending April 1, 2017, the Lea County Regional Airport had approximately 12,745 aircraft operations, an average of 35 per day: 67 percent general aviation, 16 percent air taxi, 10 percent air carrier, and 7 percent military. During this period, 52 aircraft were based at this airport: 41 single-engine, 6 multi-engine, 4 jet, and 1 helicopter [2.2.24].
Average annual aircraft operations for the past 15 years is approximately 12,500, this data is illustrated in Table 2.2.7 [2.2.28]. The missed approach holding pattern for Lea County Regional is approximately 19 miles South West of the airport, locating it just over 12.5 miles from the CIS Facility see Table 2.2.6 [2.2.31]
- Note that for Lea County Regional data reported on AiportIQ does not match the data for the same time period reported on ATADS.
Lea County - Zip Franklin Memorial Airport* also known as Lovington airport is located 3 miles west of the central business district of Lovington in Lea county, NM, approximately 32 miles from the CIS Facility. For the 12-month period ending April 3, 2017 the airport had approximately 2,200 aircraft operations, all general aviation. During this period, 12 aircraft were based at this airport: 11 single engine, and 1 multi engine [2.2.25].
- Note that Zip Franklin Memorial Airport does not have an FAA funded air traffic control tower, and therefore does not have data reported to ATADS.
Midland International Air and Space is located approximately midway between the Texas cities of Midland and Odessa. It is owned and operated by the City of Midland. In September 2014 it became the first US facility licensed by the FAA to serve both scheduled airline flights and commercial human spaceflight. Midland International Air and Space Port is ranked eighth in Texas for primary commercial service airports. For the 12-month period ending April 30, 2017, the airport has approximately 63,055 aircraft operations, averaging 173 per day: 43 percent general aviation, 14 percent air taxi, 18 percent air carrier, and 25 percent military. During this period, 105 aircraft were based at the airport: 24 single-engine, 40 multi-engine, 39 jet and 2 helicopter. The airport has three airlines, two serving hubs with regional jets and one (Southwest) flying mainline jets (Boeing 737s) [2.2.26]. Average annual aircraft operations for the past 15 years is Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-45 approximately 76,412, this data is presented in Table 2.2.8 [2.2.28].
Roswell International Air Center is located 5 miles south of the central business district of Roswell, in Chaves County, NM, approximately 68 miles from the CIS Facility. The former Air Force Base currently covers 5,029 acres and has 2 runways. It is also an FAA certified commercial airport but is served by American Airlines with daily regional flights to Dallas-Fort Worth and Phoenix. The airport is owned by the city of Roswell and also serves as a storage facility for retired aircraft. For the 12-month period ending December 31, 2016, the Roswell International Air Center had approximately 34,280 aircraft operations, an average of 94 per day: 23 percent general aviation, 18 percent air taxi, 1 percent air carrier, and 58 percent military. During this period, 39 aircraft were based there: 31 single engine, 4 multi engine, 3 jet, and 1 helicopter [2.2.27]. Average annual aircraft operations for the past 15 years is approximately 49,050, this data illustrated in Table 2.2.9
[2.2.28].
In order to assure that risks from aircraft hazards is sufficiently low, a probabilistic assessment of the nearby air transportation infrastructure as described above has been performed. NUREG-0800 Standard Review Plan, gives acceptance criteria for the probabilistic assessment to meet NRC regulations. NUREG-0800 section 3.5.1.6 states that the requirements are met if the probability of aircraft accident is less than an order of magnitude of 10-7 per year. It also provides screening criteria which, if met, the probability is considered to be less than the 10-7 threshold by inspection.
Table 2.2.4 summarizes the data presented for each of the nearby airports, including its distance from the site, annual number of operations, as well as the SRP screening criteria. The value used for annual aircraft operations is the higher of the 15-year average from ATADS or the most recent years value from AirportIQ (where both values are available). Given the distance to each of the near by airports, none of their annual operations comes within an order of magnitude of the screening criteria. Therefore, each of the nearby airports pose a negligible hazard risk.
Table 2.2.5and Table 2.2.6 summarizes the data presented for each of the federal airways, and holding or approach patterns that are near the site. The tables include distance from the site to the nearest edge of the airway or holding/approach pattern, as well as the screening criteria. Each of the proximate federal airways, holding patterns and approach patterns are greater than the 2-statute mile SRP screening criteria. Therefore, they pose a negligible hazard risk.
Table 2.2.5 also summarizes the data presented for each of the adjacent Military Training Routes, including the distance from the site to the nearest edge of the route, as well as the SRP screening criteria. The nearest edge of IR-192/194 is greater than 10 miles from the site, which is greater than the screening criteria of 5 statute miles. However, the centerline of IR-128/180 is less than 2 miles from the site, which puts its full width over top of the CIS Facility. Therefore, IR-192/194 is screened by inspection, while IR-128/180 needs to be assessed following SRP Section 3.5.1.6 III [2.2.33].
SRP Section 3.5.1.6 III provides the following equation for determining the probability of an aircraft using an airway crashing at the site:
=
Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-46 Where:
C = in-flight Crash Rate per mile for aircraft using the airway N = Number of flights per year along the airway A = effective Area of the site in square miles w = Width of the airway in miles The area of each of the important to safety structures constitutes the effective area of the site. In this case, it is conservatively taken as the out to out area of the full 10,000 cask UMAX ISFSI array plus the area of the Cask Transfer Building, A = 0.173 mi2. The total width of the airway, as noted in Table 2.2.5, is 7 miles. And using a crash rate of C = 4*10-9 (an order of magnitude greater than commercial aircraft), the number of flights per year that would yield a crash probability higher than P = 10-7 would be 1011 flights.
The Air Force Base that controls IR-128/180, Dyess AFB has stated that IR-180 has not been used in years and we do not expect to fly IR-180 in the near future, the way it's currently laid out
[2.2.32]. They also provided Figure 2.2.7 showing how IR-128 is flown and how they expect to fly it in the foreseeable future [2.2.32]. Figure 2.2.7 illustrates the racetrack which is used as part of operations on IR-128 and then exited from. This racetrack is north of Lovington, NM greater than 30 miles from the site. The portion of IR-128 closest to the site is not used. Therefore, it is reasonable to assume that less than 1011 flights per year occur on these MTRs near the site, and they pose a negligible hazard risk.
2.2.4 Ground Transportation U.S. Highway 62/180, approximately 1 mile south of the proposed CIS Facility is the closest and most trafficked public road. It provides a route from the state of Texas to Carlsbad, New Mexico and points further west. It is a divided highway with a maximum speed limit of 70 miles per hour in the area near the proposed CIS Facility. This, in addition to other transportation infrastructure near the site, can be seen in Figure 2.2.4. This highway is on the National Hazardous Materials Route Registry (79 FR 40844, July 14, 2014) and can be used for the transportation of radioactive waste materials to WIPP [2.2.7] (Note: as shown on Figure 2.2.5, the WIPP route is approximately 5 miles southwest of the CIS Facility. There have been instances where transuranic wastes associated with WIPP have been transported along U.S. Highway 62/180 within approximately 1 mile of the proposed CIS Facility).
Like similar roads, commercial shipments of hazardous materials are also transported over U.S.
Highway 62/180. Such shipments could include a wide range of hazardous materials, including, but not limited to: gasoline, diesel fuel, acids, carbon dioxide (CO2), nitrogen (N2), liquid nitrogen (LN2), chlorine (Cl) gas, refrigerants, fuel gases, oxygen (O2), explosives, and low-level radioactive materials. The State of New Mexico does not keep records of hazardous material shipments via roadways or rail. Consequently, specific types and quantities cannot be provided.
In 2015, the annual average daily traffic on U.S. Highway 62/180 was 5,696 vehicles per day in the vicinity of the proposed Site (near the Eddy-Lea County line) and approximately 43 percent of these vehicles were associated with commercial trucks [2.2.9]. In 2014, in the entire state of New Mexico, there were 69 Hazardous Material Incidents required to be reported by 49 CFR §§ 171.15 Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-52 Table 2.2.4: Nearby Airport SRP Screening Airports City Distance from Site (miles)
Average Annual Operations Screening Criteria 1000 D2 Operations Artesia Municipal (ATS)
Artesia, NM 47 14,050*
2,209,000 Cavern City (CNM)
Carlsbad, NM 34 6,900*
1,156,000 Lea County Regional (HOB)
Hobbs, NM 30 12,745 900,000 Lea Co. Zip Franklin Mem (E06)
Lovington, NM 32 2,200*
1,024,000 Roswell International (ROW)
Roswell, NM 68 49,045 4,624,000 Midland Intl air and space port (MAF)
Midland, TX 98 76,412 9,604,000 Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-53 Table 2.2.5: Nearby Federal Airway and Military Training Route SRP Screening Airways Federal/MTR Travel Direction Distance to Centerline Width left of Center Width Right of center Site Side Distance to nearest edge [miles]
Screening Criteria V-102 Federal Either 6.8 4
4 N/A 2.8
> 2 mile V-291 Federal Either 12.0 4
4 N/A 8.0
> 2 mile V-83 Federal Either 34.8 4
4 N/A 30.8
> 2 mile IR-192/
MTR N to S 13.5 3
7 Left 10.5
> 5 mile IR-194 S to N 13.5 7
3 Right IR-128/
MTR N to S 1.8 3
4 Right Over Site
> 5 mile IR-180 S to N 1.8 4
3 Left Note: Bolded items do not satisfy criteria and are discussd further in chapter Table 2.2.6: Nearby Airport Holding and Approach Pattern SRP Screening Holding/Approach Pattern Distance from Site [miles] Screening Criteria CNM Approach Pattern 22.76
>2 mile HOB Missed Approach Pattern 12.64
>2 mile Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-54 Table 2.2.7: ATADS Standard Report for LEA County Regional Airport 2003-2017 Itinerant Local Calendar State Facility Air Air General Military Total Civil Military Total Total Year Carrier Taxi Aviation Operations 2003 NM HOB 0
3,047 8,676 167 11,890 6,138 468 6,606 18,496 2004 NM HOB 0
3,002 6,850 200 10,052 5,224 344 5,568 15,620 2005 NM HOB 0
2,277 5,082 77 7,436 3,660 166 3,826 11,262 2006 NM HOB 0
2,195 4,574 72 6,841 3,694 155 3,849 10,690 2007 NM HOB 0
2,237 5,468 62 7,767 4,006 82 4,088 13,810 2008 NM HOB 0
2,388 5,165 85 7,638 5,240 188 5,428 17,366 2009 NM HOB 0
2,136 10,327 171 12,634 6,884 390 7,274 19,908 2010 NM HOB 4
2,190 9,806 280 12,280 3,991 366 4,357 16,637 2011 NM HOB 2
1,944 6,332 137 8,415 2,011 326 2,337 10,752 2012 NM HOB 0
2,264 5,817 157 8,238 856 176 1,032 9,270 2013 NM HOB 2
2,341 5,622 100 8,065 738 90 828 8,893 2014 NM HOB 0
2,358 5,153 257 7,768 511 244 755 8,523 2015 NM HOB 0
1,979 5,336 399 7,714 1,196 304 1,500 9,214 2016 NM HOB 0
2,115 5,351 374 7,840 818 226 1,044 8,884 2017 NM HOB 0
1,870 5,049 157 7,076 1,097 16 1,113 8,189 Sub-Total for HOB 8
34,343 94,608 2,695 131,654 46,064 3,541 49,605 187,514 Sub-Total for NM 8
34,343 94,608 2,695 131,654 46,064 3,541 49,605 187,514 Total:
8 34,343 94,608 2,695 131,654 46,064 3,541 49,605 187,514 15yr AVG 12,501 Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-55 Table 2.2.8: ATADS Standard Report for Midland International Air and Space Port 2003-2017 Itinerant Local Calendar State Facility Air Air General Military Total Civil Military Total Total Year Carrier Taxi Aviation Operations 2003 TX MAF 9,612 14,111 23,557 17,704 64,984 4,703 22,745 27,448 92,432 2004 TX MAF 9,603 12,264 25,137 16,555 63,559 4,149 18,401 22,550 86,109 2005 TX MAF 9,560 13,783 24,571 16,220 64,134 4,696 18,060 22,756 86,890 2006 TX MAF 10,309 15,615 26,352 16,197 68,473 4,463 16,563 21,026 89,499 2007 TX MAF 9,408 14,055 17,745 13,015 54,223 4,172 16,442 20,614 84,302 2008 TX MAF 8,613 13,827 12,608 7,747 42,795 4,129 16,369 20,498 84,037 2009 TX MAF 8,574 12,574 18,070 10,447 49,665 2,629 9,547 12,176 61,841 2010 TX MAF 8,196 14,935 22,290 10,587 56,008 2,792 11,766 14,558 70,566 2011 TX MAF 8,336 12,479 23,490 12,777 57,082 2,823 14,991 17,814 74,896 2012 TX MAF 7,903 13,850 25,202 9,972 56,927 2,466 10,345 12,811 69,738 2013 TX MAF 7,099 16,433 25,111 10,531 59,174 2,402 10,988 13,390 72,564 2014 TX MAF 8,987 15,464 27,562 10,181 62,194 3,390 11,093 14,483 76,677 2015 TX MAF 11,478 11,648 22,745 10,379 56,250 4,175 9,960 14,135 70,385 2016 TX MAF 11,033 9,370 21,423 9,878 51,704 5,471 6,733 12,204 63,908 2017 TX MAF 11,757 8,715 23,029 6,835 50,336 5,230 6,777 12,007 62,343 Sub-Total for MAF 140,468 199,123 338,892 179,025 857,508 57,690 200,780 258,470 1,146,187 Sub-Total for TX 140,468 199,123 338,892 179,025 857,508 57,690 200,780 258,470 1,146,187 Total:
140,468 199,123 338,892 179,025 857,508 57,690 200,780 258,470 1,146,187 15yr AVG 76,412 Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-56 Table 2.2.9: ATADS Standard Report for Roswell International Air Center 2003-2017 Itinerant Local Calendar State Facility Air Air General Military Total Civil Military Total Total Year Carrier Taxi Aviation Operations 2003 NM ROW 398 8,579 13,861 13,394 36,232 9,741 12,181 21,922 58,154 2004 NM ROW 94 9,418 18,547 13,495 41,554 12,800 13,032 25,832 67,386 2005 NM ROW 222 9,379 16,714 12,433 38,748 7,802 13,233 21,035 59,783 2006 NM ROW 218 8,590 19,998 15,359 44,165 7,408 15,695 23,103 67,268 2007 NM ROW 225 8,559 14,855 11,284 34,923 6,094 18,324 24,418 66,890 2008 NM ROW 301 6,953 8,735 5,580 21,569 4,396 9,532 13,928 50,108 2009 NM ROW 337 6,360 12,020 11,178 29,895 6,005 12,826 18,831 48,726 2010 NM ROW 116 6,405 9,468 10,242 26,231 4,774 20,953 25,727 51,958 2011 NM ROW 268 6,999 8,922 7,496 23,685 4,064 7,924 11,988 35,673 2012 NM ROW 603 6,168 7,232 8,309 22,312 4,373 7,986 12,359 34,671 2013 NM ROW 519 6,006 6,498 13,329 26,352 2,339 24,384 26,723 53,075 2014 NM ROW 518 6,551 7,384 12,371 26,824 3,127 16,979 20,106 46,930 2015 NM ROW 260 5,412 6,522 8,573 20,767 2,382 12,081 14,463 35,230 2016 NM ROW 285 6,116 6,317 8,771 21,489 1,630 11,161 12,791 34,280 2017 NM ROW 1,652 4,718 6,593 5,252 18,215 2,301 5,030 7,331 25,546 Sub-Total for ROW 6,016 106,213 163,666 157,066 432,961 79,236 201,321 280,557 735,678 Sub-Total for NM 6,016 106,213 163,666 157,066 432,961 79,236 201,321 280,557 735,678 Total:
6,016 106,213 163,666 157,066 432,961 79,236 201,321 280,557 735,678 15yr AVG 49,045 Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-62 Figure 2.2.6: Air Transportation Infrastructure Near the CIS Facility Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-63 Figure 2.2.7: IR-128 Exit Racetrack Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-107 With regard to potential future drilling on the Site, Holtec has an agreement [2.6.9] with Intrepid Mining LLC (Intrepid) such that Holtec controls the mineral rights on the Site and Intrepid will not conduct any potash mining on the Site. Additionally, any future oil drilling or fracking beneath the Site would occur at greater than 5,000 feet depth, which ensures there would be no subsidence concerns [2.1.8].
Based on the data from the borings and analyses, the soils at the site are not susceptible to liquefaction. The soils encountered at the site were evaluated for liquefaction potential using the methods described in Youd, et al., 2001 [2.6.12] as prescribed by Regulatory Guide 1.198 [2.6.11].
Corrected N-values greater than 30 blows per foot are too dense to liquefy in an earthquake of any size, and are therefore classified as non-liquefiable. In addition, soils above the groundwater table are not susceptible to liquefaction [2.6.12].
2.6.5 Slope Stability The site terrain ranges in elevation from 3,520 to 3,540 feet above mean sea-level sloping gently downward from south to north. Most of the site is flat with slopes ranging from 0 to 3 percent, as shown in Figure 2.6.15. Therefore, there is no risk from slope instability (i.e. landslides) in the vicinity of the Site.
2.6.6 Construction Excavation During the construction of Phase 1 of the HI-STORE CISF, there will be multiple areas where excavation will be required to accommodate and install the underground facilities; specifically, the Canister Transfer Facilities (CTF) which are located in the Cask Transfer Building (CTB), and the UMAX field. In both cases, the expected total excavation depth is approximately twenty-five (25) feet.
According to the geotechnical borings, there are two layers of subsurface material that will be encountered during construction excavations. The native caliche layer, which is approximately 12 feet in depth from top of existing grade, and the native residual soil layer, which makes up approximately 13 feet of depth for the remaining required excavation depth for site facilities. In no instance is it expected that construction excavations will encounter the native Chinle layer.
In order to accommodate construction vehicle access and industry wide safety standards, it is expected that construction practices will utilize a minimum 1:1 slope around the extents of the excavation pits. This method will create ~124,000 cubic yards (CY) of caliche spoils and ~121,500 CY of residual soil spoils; some of which (~24,000 CY) will be utilized to backfill the excavation area. It should be noted that the residual soil layer will be utilized for the backfill material as it meets the minimum density and shear wave velocity requirements that are required for Space B, referenced in Figure 4.3.1.
Once the areas have been excavated, the supporting soil will be prepared to receive the reinforced concrete Support Foundation Pad (SFP). The residual soil surfaces shall be proof rolled by a heavy vibrating compactor, prior to the placement of compacted fill or foundations. Careful observation shall be made by a professional engineer licensed in New Mexico or their approved representative during proof rolling in order to identify any areas of soft, yielding soils that may require over-excavation and replacement. Once the subsurface has been prepared and compacted, the supporting residual soil fill (Space C) shall be confirmed to have reached a compaction of 95 percent (minimum) of the modified Proctor maximum dry density (in accordance with ASTM Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 2-108 D1557). The compaction should be conducted at or close to the optimum moisture content indicated by the modified Proctor test procedure (ASTM D1557).
Upon completion of subgrade preparation/compaction, placement of the reinforced concrete Support Foundation Pad (SFP) and UMAX Cavity Enclosure Containers (CECs), backfilling of Spaces A and B (Figure 4.3.1) will commence. Space A will consist of a Controlled Low Strength Material (CLSM) or lean concrete that has a minimum compressive strength and density of 1,000 psi and 120 pcf, respectively, as referenced in Table 4.3.3. Since the backfilling process is iterative, as the fill materials are brought back up to finished grade, the sloped areas of the excavation pit that make up Space B of the UMAX lateral subgrade, will be composed of the aforementioned residual soil. Again, it is expected that for Phase 1 of the HI-STORE CISF, and all subsequent phases, ~24,000 CY of this residual soil will be required to fill out the Space B portion of the excavated area.
Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 4-17 further consideration in this SAR, are outlined in Table 4.3.1. Environmental conditions and constraints that differ from those bounded by [1.0.6], although minor in nature, are described in Table 4.3.2 and evaluated herein. With the following exceptions, all subsections of the HI-STORM UMAX FSAR are relevant to the HI-STORE CIS evaluation:
1 Criteria related to the HI-TRAC VW system. The HI-TRAC VW system is supplanted by the HI-TRAC CS system in this application, with the design criteria for the HI-TRAC CS system described herein.
2 Service conditions related to the used of Forced Helium Drying (FHD) described in Paragraph 2.3.3.5 of the HI-STORM UMAX FSAR. As the HI-STORE CIS facility accepts only pre-packaged canisters, operations related to internal canister drying are not applicable.
Information consistent with the regulatory requirements related to shielding, thermal performance, confinement, radiological, and operational considerations is also provided. The licensing drawing of the HI-STORM UMAX design variant used in the HI-STORE CIS application is included in Section 1.5 of this SAR. The licensing drawing provides information on the necessary critical characteristics that define the HI-STORE CIS UMAX system for this application.
4.3.2.1 Structural The applicable loads, affected parts under each loading condition, and the applicable structural acceptance criteria related to the HI-STORM UMAX VVM and ISFSI structures that are compiled in Section 2.0 of [1.0.6] provide a complete framework for the required qualifying safety analyses in this SAR. The VVM storage system at the HI-STORE CIS ISFSI will be functionally identical to that certified in the HI-STORM UMAX docket. The conservative approach of basing the HI-STORE CIS design on the certified HI-STORM UMAX design is supported by the following:
- 1. The subgrade and under-grade soil properties at the HI-STORE CIS site are uniformly better than those assumed for the general certification of the HI-STORM UMAX system.
These properties can be found in the geotechnical investigation completed December 2017
[2.1.24]. HI-STORE Bearing Capacity and Settlement Calculation report HI-2188143
[4.3.5] details the methodology used to compute the bearing capacity at the site. This calculation confirms the required bearing capacity is met for the soil underneath the planned construction.
- 2. The top-of-pad earthquake spectra corresponding to a 10,000-year earthquake at the HI-STORE CIS site is enveloped by that assumed for the HI-STORM UMAX in its general certification. (Subsection 4.3.6 and Table 4.3.3 provide a summary of the applicable seismic loadings for the HI-STORE CIS facility).
- 3. The long-term settlement at the HI-STORE CIS ISFSI is computed in [4.3.5] to be less than that assumed in the certification of the HI-STORM UMAX. The methodology followed is stated in the calculation itself. As stated in item 1, above, soil properties at the HI-STORE CIS site are more favorable than those assumed in the HI-STORM UMAX system certification [2.1.24].
Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 4-20 The structural qualification of HI-STAR 190 to the loadings of 10CFR71.71 (normal condition) and 10CFR71.73 (accident condition) in [1.3.6] are clearly much more severe than those encountered during its handling in the CTB. Nevertheless, certain structural requirements are unique to the operations in the CTB that are unique to the Short Term Operations. Table 4.3.6 contains the structurally significant loadings on the HI-STAR 190 cask in the Cask Transfer Building. Acceptance criteria are provided in Section 4.4.
4.3.4.2 Thermal The thermally-significant loadings on HI-STAR 190 that warrant safety demonstration are summarized in Table 4.3.6. The permissible temperature limits for all steel weldments in casks and structures used at HI-STORE, provided in Table 4.4.4, are applicable to the HI-STAR 190.
4.3.4.3 Shielding HI-STAR 190 is designed to meet the dose attenuation requirements of 10CFR71 [1.3.2] which far exceed those expected of on-site transfer casks. However, HI-STAR 190s contribution to meeting the dose limits of Part 72, set down in Subsection 4.4 herein, is considered in demonstrating compliance.
4.3.4.4 Confinement The confinement function of the canister is unaffected by the function of HI-STAR 190.
4.3.4.5 Criticality Control HI-STAR 190 does not participate in the criticality control function.
4.3.5 Canister Transfer Facility (CTF)
The HI-STORE CTF is an underground structure used to effectuate transfer of the SNF canister from the transport cask (HI-STAR 190) to the transfer cask (HI-TRAC CS).
4.3.5.1 Structural The CTF includes both structural and non-structural radiation shielding components that are classified as important-to-safety. The structural steel components of the CTF are designed to meet the stress limits of Section III, Subsection NF, of the ASME Code [4.5.1] for normal, off-normal and accident conditions, as applicable. The CTF reinforced concrete structures shall meet the applicable strength requirements of ACI 318-05 [5.3.1].
The CTF must withstand the loads associated with the weights of each of its components, including the weight of the HI-TRAC CS transfer cask with the loaded MPC stacked on top during the canister transfer, and the weight of the transport cask with the loaded MPC staged on the CTF foundation slab. The CTF shall be capable of withstanding lateral loading in a seismic event as determined by the provisions of Chapter 8 of ASCE 4 [4.3.4].
4.3.5.2 Thermal Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 4-27 Table 4.3.3 Applicable Earthquake and Long Term Settlement data for the Certified HI-STORM UMAX System and the HI-STORE CIS Facility Data HI-STORM UMAX Generic License Value (see Note 1)
HI-STORE CIS Site Value Comment 7
Strain compatible effective shear wave velocity in Space B 450 ft/sec minimum 780 ft/sec minimum Space will contain native soil.
8 Strain compatible effective shear wave velocity in Space C 485 ft/sec minimum 980 ft/sec minimum Space will contain native soil.
9 Strain compatible effective shear wave velocity in Space D, V 485 ft/sec minimum 980 ft/sec minimum Space will contain native soil.
10 Density of plain concrete in the Closure Lid (nominal) 150 lb/cubic feet 150 lb/cubic feet Used in shielding calculations 11 Reference compressive strength of plain concrete in the Closure Lid 4,000 psi 4,000 psi Used in analysis of mechanical loadings on the Closure Lid 12 Minimum compressive strength of SES in Space A (see Figure 4.3.1) 1,000 psi 1,000 psi Used in tornado missile impact analysis and SSI analysis 13 Two orthogonal horizontal and one vertical ZPAs for 10,000 -year return earthquake (DBE) 0.15,0.15, 0.15 5% Damped Reg. Guide 1.60 spectra [4.3.2]
14 Two orthogonal horizontal and one vertical ZPAs for 1000- year return earthquake (OBE) 0.10, 0.10, 0.10 2% Damped Reg. Guide 1.60 spectra [4.3.2]
15 Two orthogonal horizontal and one vertical ZPAs for Design Extended Condition Earthquake (DECE) 0.25,0.25, 0.25 5% Damped Reg. Guide 1.60 spectra [4.3.2]
Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 19-4
[2.1.19] Intrepid Potash LLC. Phone conversation with Mr. Robert Baldridge, Operations Manager for Intrepid Potash, and Jay Rose, Tetra Tech. July 25, 2017.
[2.1.20] New Mexico Bureau of Mines and Minerals Resources (NMBMMR). Potash in New Mexico. February 1980.
[2.1.21] United Nations Environment Programme (UNEP).
Environmental Aspects of Phosphate and Potash Mining. 2001.
[2.1.22] U.S. Geological Survey (USGS). Geological Survey Circular 876-- Subsidence from Underground Mining: Environmental Analysis and Planning Considerations. 1983.
[2.1.23] CEHMM. Holtec HI-Store Facility Area GIS Conflict Analysis. October 7, 2016.
[2.1.24] GEI Consultants (GEI). Geotechnical Data Report: HI-STORE CISF Phase 1 Site Characterization. February 2018.
[2.2.1]
CEHMM. Pipeline Information. E-mail from Doug Lynn, Executive Director CEHMM, to Tetra Tech on July 27, 2017.
[2.2.2]
C-FER Technologies, Stephens, Mark. A Model for Sizing High Consequence Areas Associated with Natural Gas Pipelines. October 2000.
[2.2.3] National Transportation Safety Board (NTSB). "Pipeline Accident Report PAR-03-01, dated August 19, 2000." Available at: NTSB.gov. Accessed July 2017.
[2.2.4]
Pipeline and Hazardous Materials Safety Administration (PHMSA). Pipeline Safety.
Available at: https://www.phmsa.dot.gov/. Accessed July 2017.
[2.2.5]
Delta Airlines. Personal Communication between Captain Chick Winship, Delta Air Lines and Jay Rose, Tetra Tech, on July 26, 2017.
[2.2.6] Military Training Routes (MTR).
Available at:
http://www.cfinotebook.net/notebook/national-airspace-system/military-training-routes.
Accessed on July 26, 2017.
[2.2.7]
National Hazardous Materials Route Registry (NHMRR). U.S. Department of Transportation.
Available at:
www.fmcsa.dot./gov/regulations/hazardous-materials/national-hazardous-materials-route-registry-state. Accessed on July 18, 2017.
[2.2.8]
United States Department of Transportation (USDOT) Bureau of Transportation Statistics. State Transportation Statistics. Available at: www.bts.gov. Accessed on July 18, 2017.
[2.2.9]
New Mexico Department of Transportation (NMDOT). Road Segments by Posted Route/Point with (AADT) Info. Email from Jessica Crane, NMDOT, to Tetra Tech.
November 30, 2016 Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 19-5
[2.2.10] NMDOT.
New Mexico Freight Plan.
Available at:
dot.state.nm.us/content/dam/nmdot/planning/nm_2040_plan-freight_plan.pdf. August 2015.
[2.2.11] Department of Energy (DOE). Waste Isolation Pilot Plant Disposal Phase Final Supplemental Environmental Impact Statement. DOE/EIS-0026-S2. September.
Available at: http://energy.gov/nepa/eis-0026-s2-waste-isolation-pilot-plant-disposal-phase-carlsbad-new-mexico.
[2.2.12] DOE. Waste Isolation Pilot Plant Annual Site Environmental Report for 2014.
DOE/WIPP-15-8866. September 2015.
[2.2.13] NRC. Environmental Impact Statement for the Proposed National Enrichment Facility in Lea County, New Mexico. NUREG-1790. June 2005.
[2.2.14] NRC. Environmental Impact Statement for the Proposed Fluorine Extraction Process and Depleted Uranium Deconversion Plant in Lea County, New Mexico. NUREG-2113.
August 2012.
[2.2.15] Waste Control Specialists. WCS Consolidated Interim Spent Fuel Storage Facility Environmental Report. May 2016. (Compiled from ADAMS Numbers: ML16133A137, ML16133A161, ML16133A158, ML16133A139, ML16133A162, ML16133A153, ML16133A151, ML16133A146, ML16133A145, ML16133A144, ML16133A143, ML16133A142, ML16133A099)
[2.2.16] U.S. Department of Transportation Federal Aviation Administration, Albuquerque VFR Sectional Chart, 101st Edition, 4/26/2018
[2.2.17] U.S. Department of Transportation Federal Aviation Administration, Order JO 7400.11B Airspace Designations and Reporting Points, 8/3/2017
[2.2.18] U.S. Department of Transportation Federal Aviation Administration, Order 8260.19H Flight Procedures and Airspace, 7/20/2017
[2.2.19] U.S. Department of Defense National Geospatial-Intelligence Agency, AP/1B Flight Information Publication: Area Planning: Military Training Routes: North and south America, 3/29/2018
[2.2.20] U.S. Department of Transportation Federal Aviation Administration, Aeronautical Information Services: Aeronautical Chart Users Guide, 3/29/2018
[2.2.21] 14 CFR Part 1.1, Aeronautics and Space Definitions and Abbreviations, Title 14 of the Code of Federal Regulations - Transportation, Federal Aviation Administration, Washington, D.C.
Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 19-6
[2.2.22] U.S. Department of Transportation Federal Aviation Administration, FAA Form 5010-1 FAA Airport Master Record for ATS Available at:
http://www.gcr1.com/5010web/airport.cfm?Site=ATS&AptSecNum=2, Accessed on 5/18/2018.
[2.2.23] U.S. Department of Transportation Federal Aviation Administration, FAA Form 5010-1 FAA Airport Master Record for CNM Available at:
http://www.gcr1.com/5010web/airport.cfm?Site=CNM&AptSecNum=2, Accessed on 5/18/2018.
[2.2.24] U.S. Department of Transportation Federal Aviation Administration, FAA Form 5010-1 FAA Airport Master Record for HOB Available at:
http://www.gcr1.com/5010web/airport.cfm?Site=HOB&AptSecNum=2, Accessed on 5/18/2018.
[2.2.25] U.S. Department of Transportation Federal Aviation Administration, FAA Form 5010-1 FAA Airport Master Record for E06 Available at:
http://www.gcr1.com/5010web/airport.cfm?Site=E06&AptSecNum=2, Accessed on 5/18/2018.
[2.2.26] U.S. Department of Transportation Federal Aviation Administration, FAA Form 5010-1 FAA Airport Master Record for MAF Available at:
http://www.gcr1.com/5010web/airport.cfm?Site=MAF&AptSecNum=2, Accessed on 5/18/2018.
[2.2.27] U.S. Department of Transportation Federal Aviation Administration, FAA Form 5010-1 FAA Airport Master Record for ROW Available at:
http://www.gcr1.com/5010web/airport.cfm?Site=ROW&AptSecNum=2, Accessed on 5/18/2018.
[2.2.28] U.S. Department of Transportation Federal Aviation Administration, Air Traffic Activity Data System (ATADS)
[2.2.29] U.S. Department of Transportation Federal Aviation Administration, Order 8260.3D United States Standard for Terminal Instrument Procedures (TERPS), 2/16/2018
[2.2.30] Jeppesen, Instrument Approach Chart 12-3, CNM Cavern City Air Terminal, RNAV (GPS) Runway 21
[2.2.31] Jeppesen, Instrument Approach Chart 11-1, HOB Lea County Regional Airport, ILS or LOC Runway 3, 12/29/2017
[2.2.32] Email Correspondence from Dyess AFB Airspace Manager Dwight Williams, RE:
[Non-DoD Source] Facility locations in Eddy and Lea Counties New Mexico. to Beth Bennington, Thursday, March 22, 2018 Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 19-7
[2.2.33] NUREG 0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants, U.S. Nuclear Regulatory Commission, Washington, D.C., March 2010
[2.3.1]
Western Regional Climate Center Hobbs, Lea County Airport data. Available at:
http://www.wrcc.dri.edu/cgi-bin/cliMAIN.pl?nm4028. Accessed on October 14, 2016.
[2.3.2]
Holzworth, G.C. Mixing Heights, Wind Speeds, and Potential for Urban Air Pollution Throughout The Contiguous United States. January 1972.
[2.3.3]
Greer. American Meteorological Society. Glossary of Weather and Climate. 1996.
[2.3.4]
National Oceanic and Atmospheric Administration (NOAA). Enhanced F Scale for Tornado Damage. Available at: http://www.spc.noaa.gov/faq/tornado/ef-scale.html.
Accessed on October 14, 2016.
[2.3.5]
Tornado history. Available at: http://www.tornadohistoryproject.com/tornado/New-Mexico/. October 14, 2016.
[2.4.1]
Eddy-Lea Energy Alliance (ELEA). GNEP Siting Study. 2007.
[2.4.2]
CEHMM. Holtec Hi-Store Facility Area GIS Conflict Analysis. October 7, 2016.
[2.4.3]
Federal Emergency Management Agency (FEMA). FEMA Flood Map Service Center.
Available at: https://msc.fema.gov/portal.
[2.4.4]
Hydrologic Features. 32.583, -103.708. Google Earth. February 1, 2017. Accessed on: July 21, 2017.
[2.4.5]
State of New Mexico Interstate Stream commission, Office of the State Engineer. Lea County Regional Water Plan 1999.
Available at:
http://www.ose.state.nm.us/Planning/RWP/region_16.php.
[2.4.6]
State of New Mexico Interstate Stream commission, Office of the State Engineer. Lea County Regional Water Plan 2016.
Available at:
http://www.ose.state.nm.us/Planning/RWP/Regions/16_Lea%20County/2016/Reg%20 16_Lea%20County_Regional%20Water%20Plan%202016_December%202016.pdf
[2.4.7]
NatureServe. International Ecological Classification Standard: Terrestrial Ecological Classifications. NatureServe Central Databases. Arlington, VA. U.S.A. 2009.
[2.4.8]
NatureServe. Madrean Archipelago Rapid Ecoregional Assessment Pre-Assessment Report. Arlington, Virginia. 2013.
[2.4.9]
USGS. 3D Elevation Program (Resolution 1/3 arc second (10 meters)). Available at:
https://nationalmap.gov Document ID 5025024 Attachment 2
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL Report No. HI-2167374 Proposed Rev. 0C 19-10
[3.1.5]
49 CFR 177, Carriage by Public Highway, Title 49 of the Code of Federal Regulations
- Transportation, Office of the Federal Register, Washington, D.C.
[4.0.1]
ISG-11, Cladding Considerations for the Transport and Storage of Spent Fuel, USNRC, Washington, DC, Revision 3, November 17, 2003.
[4.2.1] Holtec Position Paper DS-381, Guidelines for Specifying ITS Categories, Revision 0, dated October 8, 2012
[4.2.2] Holtec Standard Procedure HSP 345, Important-to-Safety Classification Procedure.
[4.3.1]
ASLB Hearings, Private Fuel Storage, LLC, Docket # 72-22-ISFSI, ASLBP 97-732 ISFSI, February 2005.
[4.3.2]
U.S. Nuclear Regulatory Commission, Regulatory Guide 1.60, Design Response Spectra for Seismic Design of Nuclear Power Plants, Revision 1, 1973.
[4.3.3]
U.S. Nuclear Regulatory Commission, Regulatory Guide 1.92, Combining Modal Responses and Spatial Components in Seismic Response Analysis, Revision 2, 2006.
[4.3.4]
ASCE 4-16, Seismic Analysis of Safety-Related Nuclear Structures, American Society of Civil Engineers, 2017.
[4.3.5]
HI-STORE Bearing Capacity and Settlement Calculations, Holtec Report HI-2188143, Revision 0.
[4.5.1]
ASME Boiler and Pressure Vessel Code,Section III, Division 1, Subsection NF -
Supports, 2010.
[4.5.2]
Crane Manufacturer's Association of America (CMAA), Specification #70, 1988, Section 3.3.
[4.5.3]
ASME Boiler and Pressure Vessel Code, Welding,Section IX, 2010.
[4.5.4]
AWS D1.1:2006 Structural Welding Code - Steel, 2008.
[4.5.5]
ISO 9001:2008, Quality Management Systems.
[4.5.6]
American Society of Mechanical Engineers, American National Standard, Safety Standards, Slings, ASME B30.9, 1971
[4.5.7]
National Fire Protection Association (NFPA), NFPA 70, National Electric Code.
[4.5.8]
American Society of Mechanical Engineers, American National Standard, Safety Standards, Jacks, ASME B30.1-2009.
Document ID 5025024 Attachment 2