ML18071A045

From kanterella
Jump to navigation Jump to search
FW Storage of Fuel in Canisters After Transport
ML18071A045
Person / Time
Issue date: 08/30/2017
From: Ronald Lavera
NRC/NRO/DSEA/RPAC
To: Tripp C
Environmental Review Branch
Tripp C
References
Download: ML18071A045 (2)


Text

From:

Lavera, Ronald To:

Tripp, Christopher Cc:

Burkhart, Lawrence

Subject:

FW: Storage of Fuel in Canisters after transport Date:

Wednesday, August 30, 2017 4:53:11 AM Mr. Tripp

I believe that the proposed Draft Regulatory Guide-3053 - Nuclear Criticality Safety Standards for Nuclear Materials Outside Reactor Cores, should address the following issue:

In accordance with the DOT-NRC MOU from 1979, NRC regulations do not contain any requirements for Storage in Transit and the associated Criticality Controls, since DOT 49 CFR 173 regulations regarding Criticality Safety Index and package separation, apply while the package is in transit.

Once the consignment is delivered to the reactor site, it is no longer is transit, even if it has not yet been placed in the approved new fuel storage location, i.e., the new fuel racks.

When fuel is in shipment, criticality safety is addressed by 49 CFR 173 which imposes a Criticality Safety Index and limitations on the spacing between consignments.

10 CFR 71 does not consider criticality controls during Storage In Transit, therefore, there are no criticality controls applied when multiple shipments of new fuel staged on the reactor site awaiting placement in the new fuel racks.

There is some operating experience that indicates that some reactor sites have received multiple shipments of new fuel without placing them in the approved new fuel racks.

From Federal Register/Vol. 69, No. 16 / Monday, January 26, 2004/Rules and Regulations DOT requirements restrict accumulation of packages during transport, based on summing the packages' CSI or TI, including during storage incident to transport. In light of the division of regulatory responsibilities explained in the NRC-DOT Memorandum of Understanding (44 FR 38690; July 2, 1979), the NRC exemptions for carriers in transit in 10 CFR 70.12, and DOT's proposed 49 CFR 173.457 (67 FR 21384; April 30, 2002), the NRC staff believes that storage in transit provisions proposed in §§ 71.59(c)(1), 71.22(d)(3), and 71.23(d)(3) are unwarranted. The NRC has deleted the phrase "or stored incident to transport" from these sections.

NUREG/CR-6713 Regulatory Analysis of Major Revision of 10 CFR Part 71 - Final Rule, dated 2004, states:

DOTs regulations in 49 CFR Parts 171 through 180 (often called the Hazmat Regulations) address packaging, shipper and carrier responsibilities, documentation, and radioactivity limits. In

contrast, NRCs regulations are primarily concerned with special packaging requirements for large quantities of radioactive materials. A Memorandum of Understanding (MOU) published July 2, 1979 (44 FR 38690) specifies the roles of DOT and NRC in the regulation of the transportation of radioactive materials. The MOU outlines that DOT is responsible for regulating safety in transportation of all hazardous materials, including radioactive materials, whereas the NRC is responsible for regulating safety in receipt, possession, use, and transfer of byproduct, source, and special nuclear materials.

Ron LaVera CHP Health Physicist NRO/DSEA/RPAC email - ronald.lavera@nrc.gov phone - 301-415-5306

U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852 Office - OWFN-07B01