ML18040A462
| ML18040A462 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 02/06/2017 |
| From: | Anthony Williams Tennessee Valley Authority |
| To: | Muirhead W Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation, Div of Water Resources |
| References | |
| Download: ML18040A462 (5) | |
Text
..,.
Te_nnessee Valley Anthority, Post Office Box 2000, Soddy Daisy, Tennessee 37384-2000 February 6, 2017 State of Tennessee Department of Environment and Conservation Division of Water Resources, William R. Snodgrass Tennessee Tower 312 Rosa L. Parks Avenue, 11th Floor Nashville, Tennessee 37243 Mr. Wayne Muirhead:
TENNESSEEVALLEY AUTHORITY (TVA) - SEQUOYAH NUCLEAR PLANT (SQN) - NPDES
- PERMIT NO. TN0026450-2017 ANNUAL WATER WITHDRAWAL UPDATE In accordance with the provisiOns of the Tenness~e Water Resources Information Act of 2002, T.C.A. 69-7-301 et seq., enclosed are completed Water Withdrawal Registration Forms for SQN for calendar year 2017.
As previously reported, federal agencies are not subject to laws and regulations promulgated by state governments unless Congress has clearly waived the federal government's sovereign immunity.* However,"TVA has voluntarily agreed as a matter.of policy to provide the registration
By voluntarily cooperating with the State of Tennessee in its water management programs, TVA does not waive any immunity it may have under the Constitution from State regulation.and control, nor manifest any position on who may control or own the water.
If you have any questions or need additional information, please contact Millicent Garland at (423) 843-6714 or by e-mail mrmoore@tva.gov of Sequoyah's environme.ntal staff.
I certify under penalty of law that this document and _all attachments were prepared under my direction or supervision in accordance with a system designed tq assure that qualified personnel properly gather and evaluate the information submitted. Bas*ed on my inquiry of the person or.
persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware
'ficant penalties for submitting false information, including the possibility and imprisonment fork wing violations..
--.Q;.i::fflol-1-mv L. Williams Site Vice President
- Sequoyah Nuclear Plant I
Enclosures cc (Enclosures):*
Chattanooga Environmental Field OffiGe Division of Water Pollution Control 1301 Riverfront Parkway, #206 Chattanooga, Tennessee 37402-2013 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.G. 20555
State of Tennessee DEPARTMENT OF ENVIRONMENT AND CONSERVATION Division of Water Resources William R Snodgrass Tennessee Tower 312 Ros~ L. Parks Avenue, 11th Floor Nashville, Tennessee 37243 WATER WITHDRAWAL REGISTRATION In accordance with the provisions of Tennessee Code Annotated Section 69,7-301 et seq., the Water Resources Information Act, this registration is required for anyone withdrawing an average of I 0,000 gallons or more of water pet day.
See attached instructions.
PART A. FACILITY & CONTACT INFORMATION
'{'I
,-o,**,
-628 ~--
- 2.
Water User:
TVA - Sequoyah Nuclear Plant Mailing Address: P.O. Box 2000 OPS 5N-SQN Type:
Thermal Plant (Nuclear)
City: Soddy Daisy State:.~ Zip:
37384 County:
Hamilton
- 3.
Location (if different from mailing address):
Street Address:
Sequoyah Access Road City:
Soddy - Daisy State:.TI!__ Zip:
37379 County:* Hamilton
- 4.
Number of employees at location:
1250
- 5.
Indicate the contact individual for water withdrawal information:
Name:
Millicent Garland email:
mrmoore@tva.gov
Title:
Environmental Scientist Phone:
423-843-6714 Fax:, 423-843-7428 PART B. WATER USE REPORTING PERIOD
- . 6.
Year:
2017
- 7.
(Check One):
New Operation
~
Renewal*
- 8.
List any water problems you have experienced in the last reporting period:
N/A
- 9.
Classifications of Water Use (Enter Percentage of Total use-Total must equal 100% ):
a) Domestic water, use (drinking, human consumption and general sanitation uses)_
~-- %
b) Institutional or other general uses (lawn watering, laundry) c) Irrigation of crops, pastures and nursery stock d) livestock watering (includes feed lots, dairy sanitation and fish farming) e) navigation (lock usage and flow augmentation for navigation) 100 f) thermoelectric power-production, including cooling purpo_ses (excludes -hydroelectric) g) recreational use*,* park use, golf course irrigation,_ water park use h) industrial uses include manufacturing, food processing, washing, and cooling i) hydroelectric power generation (provided none ofit is used consumptively)
% j) mining (milling or wh_ere water is used to wash or pro.cess an ore) k) dewatering (mining, quarry rock production, other operations where water is withdrawn)
--- % - I) any other use n9t defined above. Describe:
100 * %
Total (Must equal 100%)
CN-1226 (Rev: 05-15)
RDA2853
WATER WITHDRAWAL INFORMATION Year: ~2=0~1~7 __ Water Withdrawal Registration Number (From Part A, Line 1 ):
628 Company Name:
TVA - Sequoyah Nuclear Plant Copy this page and submit a completed page for each withdrawal site. See attached instructions.
Part C. Water Withdrawals Source Point ID Number:
NIA Source Point Name:
NIA Source Type: (G, S, or P): -~N~l~A ___ _
County:
--'-~------------
River Mile: _N_I_A~----------
Latitude:
___,_N=IA_,__ _________ _
Longitude: _N_I_A __________ _
Datum (NAO 27 or NAO 83): __,N'-"l-'-'Ac__ __ _
Map:
X NA On File Attached Method of Measure (A, B, C, D, or E):
NIA JAN Total Withdrawals:
__.c-"-'---------
FEB Total Withdrawals:
---'-~-----
APR Total Withdrawals:
-~'--'-------
MAY Total Withdrawals:
NIA JUNE Total Withdrawals:
--'--'------MG JULY Total Withdrawals:
-~~-----
SEPT Total Withdrawals: _ _,N=/~A ____ MG OCT Total Withdrawals:
_ __,_,,N=/A~ ___ MG NOV Total Withdrawals:
__,_.N.,_./A=>--____ MG DEC Total Withdrawals:
- 10. Total Annual Withdrawals: --'-'N"--IA'--___ MG
- 11. Total# Days Water Withdrawn in Year:
365
- 12. Grand Total Water Withdrawals:
567532.10 Part D. Water Discharge (if applicable)
Discharge Point ID Number: __
1_0_1*~--
Discharge Point Name:
TN River (Diffuser Pond)
NPDES Permit No.:
TN0026450 County:
Hamilton River Mile: _4~8=3"'-.6=5=----------,---
Latitude:
35 35 Longitude:
85 14 Datum: NAO 27 or 83: ___
N_A_D_2_7 ___ _
Map on file or attached:
on File Method of Measure (A, B, C, D, or E):
E JAN Total Discharge:
FEB Total Discharge:
MAR Total Discharge:
APR Total Discharge:
MAY Total Discharge:
JUNE Total Discharge:
JULY Total Discharge:
AUG Total Discharge:
SEPT Total Discharg~:
OCT Total Discharge:
NOV Total Discharge:
DEC Total Discharge:
50836.04 44731.58 48575.87 54830.28 44336.68 52266.34 58797.37 56342.66 MG MG MG MG MG MG MG MG
~6~1~1=0=6-2=0 __ MG
_5=3~4"-'-1=0.=3,,,_2 __ MG
-~5=23~0~5-'-'-.7~7 __ MG 51510.80 MG
- 17. Total Annual Discharges:
619049.93 MG MG 18. Grand Total Discharges:
619057.23 MG
- 13. Grand Total #Days Water Withdrawn in Year:
365.
- 14. Average Daily Water Withdrawals:
1554.48 MOD
-'-'=-'-'--'-=-------
- 15. Maximum Day Water Withdrawal:
1654.90
'MG
--'-C..C.-'-'-"-'--------
- 16. Maximum Day Water Withdrawal occurred in this month:
June Part E. Signature l certify, under penalty of law, including but not limited to penalties for perjury. that this document and all attachments were prepared by me. or under my direction or supervision; that all of the submitted information is to the best ofmy knowledge and belief true. accurate, and complete:
and that lam lawfully present in the United States as a U.S. citizen or a qualified alien as*defined in 8 U.S.C. § 1641(b). As specified in Tennessee Code Annotated Section 39-I 6-702(a)( 4 ), this declaration is made under penalty of pe~jury. l understand that the penalties for providing false information and making false or fraudulent statements or representations include revocation in a fine, permit or license. civil penalties. and/or criminal prosecution resulting in a fine;imprisonment or both.
Date:
- 19. Print Name:
Title:
Site Vice President CN-1226(
RDA 2853
WATER WITHDRAWAL INFORMATION Year: 2017 Water Withdrawal Registration Number (From Part A, Line 1 ):
628 Company Name:
TVA - Sequoyah Nuclear Plant Copy this page and submit a completed page for each withdrawal site. See attached instructions.
Part C. Water Withdrawals Source Point ID Number:
N/A Source Point Name: _T-'-N'---R---"--iv--'--e'---r ~(C'---C_W)~------
Source Type: (G, S, or P): -~-----
County:
Hamilton River Mile: _4~8~5~.2~----------
Latitude:
35 33 Longitude: 85 13 Datum (NAO 27 or NAO 83):
NAD 27 Map:
- NA X
- On File Method of Measure (A, B, C, D, or E):
JAN Total Withdrawals:
44161.92 Attached B
MG FEB Total Withdrawals:
37699.2 MG MAR Total Withdrawals:
42276.96 MG APR Total Withdrawals:
47931.84 MAY Total Withdrawals:
37160.64 JUNE Total Withdrawals:
48470.4 JULY Total Withdrawals:
50086.08 AUG Total Withdrawals:
50086.08 SEPT Total Withdrawals:
48470 4 OCT Total Withdrawals:
49547 52 NOV Total Withdrawals:
4847Q 4 DEC Total Withdrawals:
49816.8
- 10. Total Annual Withdrawals:
554178.24 MG MG MG MG MG MG MG MG MG MG Part D. Water Discharge (if applicable)
Discharge Point ID Number: __ 1_1_6~--
Discharge Point Name:
TN River (CCW)
NPDES Permit No.:
TN0026450 County:
Hamilton River Mile:
485.2 Latitude:
35 33 Longitude:
85 13 Datum: NAO 27 or 83:
NAD27 Map on file or attached:
-~O~o~E=ife _____ _
Method of Measure (A, B, C, D, or E):
B JAN Total Discharge:
FEB Total Discharge:
MAR Total Discharge:
APR Total Discharge:
MAY Total Discharge:
JUNE Total Discharge:
JULY Total Discharge:
AUG Total Discharge:
SEPT Total Discharge:
OCT Total Discharge:
NOV Total Discharge:
DEC Total Discharge:
-~0.-'-18=2=5 ___ MG 0.1825 MG 0.1825 MG
___,0,..,_.1.,_,8=2=-5 ___ MG 0.1825 MG 0.1825 MG
---'O"-'-. 1C-"8=25"--__ M G 0.1825 MG
___,.O'"--W1 8.,.2~5,__--'-_ MG
_0=*~18=2=5~ __ MG
--"-0'--'.1-"-8=52;c.__ __ MG 0.1825 MG
- 17. Total Annual Discharges:
_2_.1"""'"9 ___ MG
- 11. Total# Days Water Withdrawn in Year:
_3_6"""'"5 __ _
- 12. Grand Total Water Withdrawals:
_5_6_7_5_32_._1_0 __ MG 18. Grand Total Discharges:
619057.23 MG
- 13. Grand Total# Days Water Withdrawn in Year:
365
- 14. Average Daily Water Withdrawals: ___
1~5=5~4~.4=8 __ MGD
- 15. Maximum Day Water Withdrawal:
_16'-5_4._9 _____ MG
- 16. Maximum Day Water Withdrawal occ~rred in this month:
June Part E. Signature I certify. under penalty of law, including but not limited to penalties for perjury, that this document and all attachments were prepared by me, or under my direction or supervision; that all of the submitted information is to the best ofmy knowledge and belief true. accurate. and complete:
and that I am lawfully-present in the United States as a U.S. citizen or a qualified alien as defined in 8 U.S.C. ~ 1641 (b). As specified in Tennessee Code Annotated Section 39-16-702(a)(4), this declaration is made under penalty of perjury. l understand that the penalties for providing false information and making false or fraudulent statements or representations include revocation in a fine. permit or license. civil penalties, and/or criminal prosecution resulting in a fine. imprisonment or both.
Date:
- 19. Print Na
Title:
Site Vice President RDA2853
WATER WITHDRAWAL INFORMATION Year: -"2=0'--'-1.,__7 __ Water Withdrawal Registration Number (From Part A, Line I):
628 Company Name:
TVA - Sequoyah Nuclear Plant Copy this page and submit a completed page for each withdrawal site. See attached instructions.
Part C. Water Withdrawals Source Point ID Number:
NIA Source Point Name:
TN River (ERCW)
Source Type: (G, S, or P): ---""'-------
County:
Hamilton River Mile: _4~8=--4'-'-.=85=----------
Latitude:
35 32 Longitude: 85 13 Datum (NAO 27 or NAO 83 ):. NAO 27 Map:
NA
_!S._ On File Method of Measure (A, B, C, D, or E):
Attached B
JAN Total Withdrawals:
1081.64 MG FEB Total Withdrawals:
........,;:9c..:.7..::0.:...:.6=0 ____ MG MAR Total Withdrawals:
1083.73 MG APR Total Withdrawals:
_1.c...cOc.-=8--=.5.:...:.3c..:.7 ____ MG MAY Total Withdrawals:
1150.24 JUNE Total Withdrawals:
1176. 75 JULY Total Withdrawals:
1210.60 AUG Total Withdrawals:
1215.03 SEPT Total Withdrawals:
1123 25 OCT Total Withdrawals:
1139 98 NOV Total Withdrawals:
1055 13 DEC Total Withdrawals:
1061.57 MG MG MG MG MG MG MG MG
- 10. Total Annual Withdrawals:
---"-1 "'-33_5~3~.8~6 ___ MG
- 11. Total# Days Water Withdrawn in Year:
365 Part D. Water Discharge (if applicable)
Discharge Point ID Number: __
1_1_7 __ _
Discharge Point Name:
TN River (ERCW)
NPDES Permit No.:
TN0026450 County:
Hamilton River Mile: _...:.4:,c_84_,_,...:8:,c_5 _______ _
Latitude:
35 32 Longitude:
85 13 Datum: NAO 27 or 83: ---'N..c.A...:.D---=:2.c..7 ___ _
Map on file or attached:
_....,O"'"nL.L.J...E.uiJ,.._e _____ _
Method of Measure (A, B, C, D, or E):
B JAN Total Discharge:
FEB Total Discharge:
MAR Total Discharge:
APR Total Discharge:
MAY Total Discharge:
JUNE Total Discharge:
JULY Total Discharge:
AUG Total Discharge:
SEPT Total Discharge:
OCT Total Discharge:
NOV Total Discharge:
DEC Total Discharge:
-=0.'-'4=25=.::8c....,._ __ MG 0.4258 MG 0.4258 MG
_-=..;o:c...:.42=5=-=8~ __ MG
-~0.~4~25~8:......._ __ MG
--"0"-'.4=2=58'---__ MG
____,0=42..,5~8~ __ MG
-=O.c..!.42=5=8'---__ MG
_--=.0.:...,;.4=2=58~ __ MG
_O::..:.*...:.c42=5:..::8 ___ MG.
- 17. Total Annual Discharges: _5_.1_1 ___ MG
- 12. Grand Total Water Withdrawals:
_5_67_5_3_2_.1_0 __ MG 18. Grand Total Discharges:
619057.23 MG
- 13. Grand Total# Days Water Withdrawn in Year:
365
)
- 14. Average Daily Water Withdrawals:
_1~5~54~.4~8'---____ MGD
- 15. Maximum Day Water Withdrawal:
1654.90 MG
.16. Maximum Day Water Withdrawal occurred in this month:
June Part E. Signature I certify, under penalty oflaw, including but not limited to penalties for perjury. that this document and aH attachments were prepared by me, or under my direction or supervision; that all of the submitted information is to the best ofmy knowledge and belief true. accurate. and complete; and that I am lawfully present in the United States as a U.S. citizen or a qualified alien as defined in 8 U.S.C. § 1641 (b). As specified in Tennessee Code Annotated Section 39-16-702(a)(4), this declaration is made under penalty of perjury. I understand that the penalties for providing false information and making false or fraudulent statements or representations include revocation in a fine. permit or license. civil penalties. and/or criminal prosecution resulting in isonment or both.
Date:
Title:
SiteVice President RDA2853