ML18036A714
| ML18036A714 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry |
| Issue date: | 02/07/2018 |
| From: | Tennessee Valley Authority |
| To: | Farideh Saba Plant Licensing Branch II |
| Saba F DORL/LPL2-2 301-415-1447 | |
| References | |
| Download: ML18036A714 (13) | |
Text
Browns Ferry Nuclear Plant Emergency Response Organization Staffing and Augmentation License Amendment Request Pre-Submittal Call Meeting February 7, 2018
Participants WaltLee,TVAEmergencyPreparedness(EP)Director JoshPerrel,TVAEPPlanandProcedures DennisJones,TVAEPSpecialProjects EdSchrull,TVAFleetLicensingManager GordonWilliams,TVAFleetLicensing BradTidwell,TVABFNEPManager MonicaRay,EnergyComplianceConsultants 2
BFNEROStaffingLARl
Agenda
- Purpose
- EmergencyPlanLicensingBasis
- ProposedChanges
- Precedent
- RegulatoryRequirementsandGuidance
- Schedule
- Conclusion
- Questions 3
BFNEROStaffingLARl
Purpose TooutlineproposedBrownsFerryNuclearPlant(BFN)
EmergencyPlanchangesandtheconsiderationsusedin developmentoftheLicenseAmendmentRequest, including:
- RegulatoryRequirements
- RegulatoryGuidance
- CurrentNRCStaffpositions
- SequoyahNuclearPlantDraftRequestsforAdditional Information(RAIs) 4 BFNEROStaffingLARl
LicensingBasis
- BFNEmergencyPlan,Revision0,wasapprovedby theNRCbySafetyEvaluationReportdated November1,1988
- NPREP(Generic)whichcontainsfleetwideinformation
[CurrentRevision107]
- BFNSiteSpecificREPAppendixA[CurrentRevision108]
5 BFNEROStaffingLARl
ProposedChanges Eliminate30minuteaugmentedresponsepositions Extendtherequirementfordispatchofsamplingteamsfrom30and 60minutesto60and90minutes ExtendaugmentationresponsetimesforonsiteEROpersonnelto 90minutes ReducethenumberofRadiationProtection(RP)immediate responsepositionsfrom12 to6 TransitiononshiftdoseassessmentfunctionfromRPtoChemistry Removemaintenancepersonnelfromonshift Eliminatethe60minuteaugmentedresponsebytheRadwaste Operator(RWO)
RemoveotherasneededsupportpositionsfromREPAppendixA EmergencyPlanFigures 6
BFNEROStaffingLARl
Precedent SafetyEvaluationsissuedforthefollowing:
- Susquehanna(ML030830543)
- Fermi(ML112450464)
- RiverBend(ML012710218)
- WattsBar(ML041810056)
- PointBeach(ML16118A154)
- DuaneArnold(ML17220A026)
RequestsforAdditionalInformation(RAIs)associatedwith theSequoyahNuclearPlantsubmittaldatedSeptember29, 2017.(ML17272A940) 7 BFNEROStaffingLARl
ApplicableRegulatoryRequirements
- 10CFR50,AppendixE
BFNEROStaffingLARl
ApplicableGuidanceDocuments
- RG1.219,GuidanceonMakingChangestoEmergencyPlans forNuclearPowerReactors,Revision1
- NSIR/DPRISG01,EmergencyPlanningforNuclearPower Plants
- NEI1005,AssessmentofOnShiftEmergencyResponse OrganizationStaffingandCapabilities
- NUREG0654/FEMAREP1,CriteriaforPreparationand EvaluationofRadiologicalEmergencyResponsePlansand PreparednessinSupportofNuclearPowerPlants,Revision1
- RIS201610,LicenseAmendmentRequestsforChangesto EmergencyResponseOrganizationStaffingand Augmentation BFNEROStaffingLARl 9
Schedule
- SubmitinMarch2018
- Requestapprovalwithinoneyearofsubmittal acceptance
- Proposea180dayimplementationperiod BFNEROStaffingLARl10
Conclusion Basedonthetechnical,functional,andstaffing analysesperformed,TVAhasconcludedthatthe proposedchanges:
- MaintainsupportfortherequiredEmergencyPlan functions
- Continuetoensuretheprotectionofpublichealth andsafety
- Complywithapplicableregulatoryrequirements BFNEROStaffingLARl11
Questions?
12 BFNEROStaffingLARl
13 BFNEROStaffingLARl