Department of Nuclear Engineering The University of New Mexico MSC01 1120 1 University of New Mexico Albuquerque, NM 87131-0001 Phone 505.277.5431 Fax 505.277.5433 engineering.unm.edu 209 Farris Engineering Center September 19, 2017 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington D.C. 20555 Review of the technical specifications for the AGN-201M reactor located at the University of New Mexico, Docket 50-252 indicated that the following changes are needed:

The definition of Safety Limit 1.1.29 needs to read as:

1.1.29 Safety Limit (SL) - Limits upon important process variables that are found to be necessary to reasonably protect the integrity of certain of the physical barriers that guard against the uncontrolled release of radioactivity.

There was a lack of version control during the license renewal process resulting in two inconsistencies in the text. In Section 6.1.7, the title of the Radiation Control Committee was incorrectly given as Committee on Radiation Control. Section 6.1.11 was incorrectly numbered as 6.1.12. These two errors meant that the version of the Technical Specification sent with the Amendment Request in 2014 were inconsistent with the Technical Specifications issued with the license renewal in 2011.

Under Section 3.4.c, the last sentence is confusing. Because the lead-in to Sections a through e.

starts with the phrase, During Reactor Operation: the phrase as the end of 3.4.c during operation is redundant and should be deleted. Section 3.4.c should read as, The top of the reactor shall be considered a high radiation area, and the access stairs to the top of the reactor shall be equipped with a gate and a lock for access control. The keys for the gate shall be in control of the reactor operator.

Again, a lack of version control during the license renewal process resulting in inconsistencies in the text. In the Technical Specifications issued with the license renewal, Section 4.4.b incorrectly references 3.4.d as the location of the description for reactor access control. This error also appears in the first paragraph under Basis in Section 4.4. During license renewal, there was a 3.4.c, but it was subsumed into 3.4.b. When this was done, the specifications following this were renumbered so that 3.4.d became 3.4.c, etc.. However, the references to the old 3.4.d were not updated to reflect this change. Thus the reference in Section 4.4.b and in the Basis section of Section 4.4 should be to 3.4.c.

Department of Nuclear Engineering The University of New Mexico MSC01 1120 1 University of New Mexico Albuquerque, NM 87131-0001 Phone 505.277.5431 Fax 505.277.5433 engineering.unm.edu 209 Farris Engineering Center If you have any questions or comments, please let us know.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on September 19, 2017.

Robert D. Busch, Ph.D, P.E.

Chief Reactor Supervisor (505) 277-8027 Email:

From:

Robert Douglas Busch To:

Allen Eben

Subject:

[External_Sender] TS Amend New Date:

Tuesday, September 19, 2017 5:21:36 PM Attachments:

image003.png NRC Tech Specs 2017 letter with oath pdf Eben, Attached is the letter responding to the information needed for the Amendment to the Technical Specifications for the UNM AGN-201 Reactor. Docket 252. Please let me know if there are questions or if additional material is needed.

From: Allen, Eben Sent: Tuesday, September 19, 2017 2:07:15 PM To: Robert Douglas Busch

Subject:

FW: Accession Number Help

From: ADAMS IM Sent: Tuesday, September 19, 2017 4:05 PM To: Allen, Eben

Subject:

RE: Accession Number Help

Hello Eben, Once you click on the following WEBBased ADAMS Link:

https://adams.nrc.gov/wba/

click on the Advanced Search - enter the Accession Number/Value and click on Search. The file is then displayed.

US NRC ADAMS Common Web Interface adams.nrc.gov Microsoft Internet Explorer 7.x, 6.x, and 5.x Open Internet Explorer; Select Internet Options from the Tools menu. In Internet Options dialog box select the Security tab.

Thank you, Susan Hicks On Behalf of ADAMS IM

I work at an alternate location on Mondays, Thursdays, and Fridays, and I can be reached at 703.493.8294.

From: Allen, Eben Sent: Tuesday, September 19, 2017 3:55 PM To: ADAMS IM

Subject:

Accession Number Help

ADAMS 8 has this accession number listed as being public ML17243A450, but I cant seem to find it on the public ADAMS. Has it been declared?

Eben Allen Project Manager Research and Test Reactors U.S. Nuclear Regulatory Commission (301) 415-4246