Annual Radiological Environmental Operating Report 1 January Through 31 December 2016
ML17170A141
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 05/31/2017
From:
Teledyne Brown Engineering Environmental Services
To:
Office of Nuclear Material Safety and Safeguards
References
ZS-2017-0066
Download: ML17170A141 (101)


Text

Docket No:

50-295 50-304 72-1037 ZION NUCLEAR POWER STATION UNITS 1 and 2 Annual Radiological Environmental Operating Report 1 January through 31December2016 Prepared By Teledyne Brown Engineering Environmental Services

-~

~~~~~~~~-z10NSOLUTION&-ic~~~~~~~~-

  • An EnergtSa/u!iMs Corri~ny Zion Nuclear Power Station Zion, IL 60099 May 2017

Table Of Contents I. Summary and Conclusions.............................................................................................. 1 II. Introduction...................................................................................................................... 2 A. Objectives of the REMP....................................................................................... 2 B. Implementation of the Objectives........................................................................ 2 Ill. Program Description....................................................................................................... 2 A. Sample Collection................................................................................................ 2 B. Sample Analysis.................................................................................................. 4 C. Data Interpretation............................................................................................... 5 D. Program Exceptions............................................................................................ E?

E. Program Changes............................................................................................... 6 IV. Results and Discussion................................................................................................. 7 A. Aquatic Environment........................................................................................... 7

1. Public Water.............................................................................................. 7
2. Fish........................................................................................................... 7
3. Sediment................................................................................................... 7 B. Atmospheric Environment................................................................................... 8
1. Airborne.................................................................................................... 8
a. Air Particulates............................................................................... 8 C. Terrestrial Environment....................................................................................... 8
1. Food Product............................................................................................ 8 D. Ambient Gamma Radiation................................................................................. 9 E. Land Use Survey................................................................................................. 9 F. Errata Data......................................................................................................... 10 G. Summary of Results - Inter-laboratory Comparison Program.......................... 10

Appendix A Tables Table A-1 Appendix B Tables Table B-1 Table B-2 Figures Figure B-1 Figure B-2 Figure B-3 Appendix C Tables Table C-1.1 Table C-1.2 Table C-1.3 Table C-11.1 Table C-111.1 Appendices Radiological Environmental Monitoring Report Summary

  • Radiological Environmental Monitoring Program Annual Summary for the Zion Nuclear Power Station, 2016 Location Designation, Distance & Direction, and Sample Collection &

Analytical Methods Radiological Environmental Monitoring Program - Sampling Locations, Distance and Direction, Zion Nuclear Power Station, 2016 Radiological Environmental Monitoring Program - Summary of Sample Collection and Analytical Methods, Zion Nuclear Power Station, 2016 Inner Ring TLD and Fixed Air Sampler Locations of the Zion Nuclear Power Station, 2016 Outer Ring TLD and Fixed Air Sampler Locations of the Zion Nuclear Power Station, 2016 Fish, Water and Sediment Sampling Locations of the Zion Nuclear Power Station, 2016 Data Tables and Figures - Primary Laboratory Concentrations of Gross Beta in Public Water Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Concentrations of Tritium in Public Water Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Concentrations of Gamma Emitters in Public Water Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Concentrations of Gamma Emitters in Fish Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Concentrations of Gamma Emitters in Sediment Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 ii

Table C-IV.1 Table C-IV.2 Table C-IV.3 Table C-V.1 Table C-Vl.1 Table C-Vl.2 Table C-Vl.3 Figures Figure C-1 Figure C-2 Figure C-3 Figure C-4 Figure C-5 Figure C-6 Concentrations of Gross Beta in Air Particulate Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Monthly and Yearly Mean Values of Gross Beta Concentrations (E-3 pCi/cu meter) in Air Particulate Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Concentrations of Gamma Emitters in Air Particulate Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Concentration of Gamma Emitters in Vegetation Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Quarterly TLD Results for Zion Nuclear Power Station, 2016 Mean Quarterly TLD Results for the Inner Ring, ISFSI Inner Ring, Outer Ring, Other and Control Locations for Zion Nuclear Power Station, 2016 Summary of the Ambient Dosimetry Program for Zion Nuclear Power Station, 2016 Public Water - Gross Beta - Stations Z-14 and Z-15 Collected in the Vicinity of ZNPS, 2000 - 2016 Public Water-Gross Beta - Stations Z-16 and Z~18 Collected in the Vicinity of ZNPS, 2000 - 2016 Public Water - Tritium - Stations Z-14 and Z-15 Collected in the Vicinity of ZNPS, 2000 - 2016 Public Water-Tritium - Stations Z-16 and Z-18 Collected in the Vicinity of ZNPS, 2000 - 2016 Air Particulates - Gross Beta - Stations Z-01 and Z-02 Collected in the Vicinity of ZNPS, 2000 - 2016 Air Particulate - Gross Beta - Stations Z-03 and Z-13 Collected in the Vicinity of ZNPS, 2000 - 2016 Appendix D Inter-Laboratory Comparison Program Tables Table D-1 Table D-2 Table D-3 Analytics Environmental Radioactivity Cross Check Program Teledyne Brown.Engineering, 2016 DOE's Mixed Analyte Performance Evaluation Program (MAPEP)

Teledyne Brown Engineering, 2016 ERA Environmental Radioactivity Cross Check Program Teledyne Brown Engineering, 2016 iii

Table D-4 Table D-5 Appendix E Appendix F Appendix G ERA Statistical Summary Proficiency Testing Program Environmental, Inc., 2016 DOE's Mixed Analyte Performance Evaluation Program (MAPEP)

Environmental, Inc., 2016

  • Effluent Data Meteorological Data Annual Radiological Groundwater Protection Program Report (ARGPPR)
  • iv

I.

Summary and Conclusions This report on the Radiological Environmental Monitoring Program conducted for the Zion Nuclear Power Station (ZNPS) by ZionSo/utions (ZS) covers the period 1 January 2016 through 31 December 2016. During that time period, 609 analyses were performed on 529 samples. In assessing all the data gathered for this report and *comparing these results with preoperational data, it was concluded that the operation of ZNPS had no adverse radiological impact on the environment.

Public water samples were analyzed for concentrations of gross beta, tritium and gamma-emitting nuclides. No fission or activation products were detected.

Gross beta activities detected were consistent with those detected in previous years.

Fish (commercially and recreationally important species) and sediment samples were analyzed for concentrations of gamma-emitting nuclides. No Cesium-137 (Cs-1.37) activity was detected in fish or sediment samples. No plant produced fission or activation products were found in fish or sediment.

Air particulate samples were analyzed for concentrations of gross beta and gamma-emitting nuclides. No fission or activation products were detected.

Environmental gamma radiation measurements were performed quarterly using thermoluminescent dosimeters.

1

Intentionally left blank

II.

Introduction The Zion Nuclear Power Station (ZNPS), consisted of two 1, 100 MWt pressurized water reactors was owned and operated by Exelon Corporation, is located in Zion, Illinois adjacent to Lake Michigan. Unit No. 1 went critical in December 1973. Unit No. 2 went critical in September 1974. The plant permanently ceased operation in January of 1998 and has been permanently defueled. The plant is in an advanced state of decommissioning. The site is located in northeast Illinois on the western shore of Lake Michigan, approximately 50 miles north of Chicago, Illinois.

This report covers those analyses performed by Teledyne Brown Engineering (TBE), Mirion Technologies and Environmental Inc. (Midwest Labs) on samples collected during the period 1 January 2016 through 31 December 2016.

A.

Objectives of the REMP The objectives of the REMP are to:

1.

Provide data on measurable levels of radiation and radioactive materials in the site environs

2.

Evaluate the relationship between quantities of radioactive material released from the plant and resultant radiation doses to individuals from principal pathways of exposure B.

Implementation of the Objectives The implementation of the objectives is accomplished by:

1.

Identifying significant exposure pathways

2.

Establishing baseline radiological data of media within those pathways

3.

Continuously monitoring those media before, during and after Station operation to assess Station radiological effects (if any) on man and the environment Ill.

Program Description A.

Sample Collection Samples for the ZNPS REMP were collected for ZS by Environmental Inc. (Midwest Labs). This section describes the general collection methods used by Environmental Inc. (Midwest Labs) to obtain environmental samples for the ZNPS REMP in 2016. Sample locations and descriptions can be found in Table B-1 and Figures B-1 and B-2, 2

Appendix B. The sampling methods used by Environmental Inc.

(Midwest Labs) are listed in Table B-2.

Aquatic Environment The aquatic environment was evaluated by performing radiological analyses on samples of public water, fish and sediment. Two gallon water samples were collected monthly from four public water locations (Z-14, Z-15, Z-16 and Z-18). Control locations were Z-14 and Z-18. All samples were collected in new unused plastic bottles, which were rinsed at least twice with source water prior to collection. Fish samples comprising the flesh of white sucker, northern pike, common carp, brown trout, lake trout, and burbot were collected semiannually at two locations, Z-26 and Z-27. Sediment samples composed of recently deposited substrate were collected at one location semiannually, Z-25.

Atmospheric Environment The atmospheric environment was evaluated by performing radiological analyses on samples of air particulates. Airborne particulate samples were collected and analyzed weekly at four locations (Z-01, Z-02, Z-03, and 2-13). The control location was Z-13. Airborne particulate samples were obtained at each location, using a vacuum pump with glass fiber filters attached. The pumps were run continuously and sampled air at the rate of approximately one cubic foot per minute. The filters were replaced weekly and sent to the laboratory for analysis.

Terrestrial Environment The terrestrial environment was evaluated by performing radiological analyses on food product samples. Food products were collected annually in September at three locations (Z-Control, Z-Quad 3 and Z-Qu<<;id 4). The control location was Z-Control. Various types of samples were collected and placed in new unused plastic bags and sent to the laboratory for' analysis.

Ambient Gamma Radiation Direct radiation measurements were made using 2 CaF 200 and 2 LiF 100 ~iF '4-chip Harshaw thermoluminescent dosimeters (TLD) until the 3rd Quarter of 2016. Starting the 4th Quarter of 2016, all TLD's were replaced with Panasolik Environmental TLD type 814 with 3 CaSQ4 elements that do not give an over-response to neutrons. Each location consisted of 2 TLD sets. The TLD locations were placed on and around the ZNPS site at the following locations:

Inner Ring: Z"701, Z-02, Z-03, Z-101, Z-102, Z-103, Z-104, Z-105,*Z-106, Z-107, Z-108, Z-109, Z-112, Z-113, Z-114, Z-115, Z-121, Z-124, Z-125, Z-3

129, Z-130, Z-131 Special Interest: Z-113, Z-114, Z-115 Outer Ring: Z-209, Z-211, Z-212, Z-213, Z-214, Z-215, Z-216 Control: Z-13 The specific TLD locations were determined by the following criteria:

1.

The presence of relatively dense population;

2.

Site meteorological data taking into account distance and elevation for each of the sixteen-22 1/2 degree sectors around the site, where estimated annual dose from ZNPS, if any, would be most significant;

3.

On hills free from local obstructions and within sight of the vents (where practical);

4.

And near the closest dwelling to the vents in the prevailing downwind direction.

{Two TLDs - each comprised of two CaF2 200 and 2 LiF 100 LiF 4-chip thermoluminescent phosphors enclosed in plastic - were placed at each location approximately four to eight feet above ground level. The TLDs were exchanged quarterly and sent to Mirion Technologies for analysis.

B.

Sample Analysis This section describes the general analytical methodologies used by TBE and Environmental Inc. (Midwest Labs) to analyze the environmental samples for radioactivity for the ZNPS REMP in 2016. The analytical procedures used by the laboratories are listed in Table B-2.

In order to achieve the stated objectives, the current program includes the following analyses:

1.

Concentrations of beta emitters in public water and air particulates

2.

Concentrations of gamma emitters in public water, air particulates, fish, and sediment

3.

Concentrations of tritium in public water

4.

Ambient gamma radiation levels at various site environs 4

C.

Data Interpretation The radiological and direct radiation data collected prior to Zion Nuclear Power Station becoming operational were used as a baseline with which these operational data were compared. For the purpose of this report, Zion Nuclear Power Station was considered operational at initial criticality. In addition, data was compared to previous years' operational data for consistency and trending. Several factors were important in the interpretation of the data:

1.

Lower Limit of Detection and Minimum Detectable Concentration The lower limit of detection (LLD) is defined as the smallest concentration of radioactive material in a sample that would yield a net count (above background) that would be detected with only a 5% probability of falsely concluding that a blank observation represents a "real" signal. The LLD is intended as a before the fact estimate of a system (including instrumentation, procedure and sample type) and not as an after the fact criteria for the presence of activity. All analyses were designed to achieve the required ZNPS detection capabilities for environmental sample analysis.

The minimum detectable concentration (MDC) is defined above with the exception that the measurement is an after the fact estimate of the presence of activity.

2.

Net Activity Calculation and Reporting of Results Net activity for a sample was calculated by subtracting background activity from the sample activity. Since the REMP measures extremely small changes in radioactivity in the environment, background variations may result in sample activity being lower than the background activity affecting a negative number. An MDC was reported in all cases where positive activity was not detected.

Gamma spectroscopy results for each type of sample were grouped as follows:

For public water, sediment and air particulates 11 nuclides, Mn-54, Co-58, Fe-59, Co-60, Zn-65, Nb-95, Zr-95, Cs-134, Cs-137, Ba-140, and La-140 were reported.

Means and standard deviations of the results were calculated.

The standard deviations represent the variability of measured results for different samples rather than single analysis uncertainty.

5

D.

Program Exceptions For 2016 the ZNPS REMP had a sample recovery rate in excess of 98%.

Sample anomalies and missed samples are listed in the tables below:

Sample Type AP AP Sample Type TLD Table D-1 Location Code Z-02 Z-02 Table D-2 Location Code Z-02-2 LISTING OF SAMPLE ANOMALIES Collection Reason Date 01/20/16 No apparent reason for low reading of 121.6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 11/16/16 Timer malfunction; collector replaced timer. Timer reading of 1638.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> based on previous weeks' time.

LISTING OF MISSED SAMPLES Collection Date 12/20/16 Reason TLD missing during weekly check; collector placed spare.

Each program exception was reviewed to understand the causes of the program exception. Sampling and maintenance errors were reviewed with the personnel involved to prevent recurrence. Occasional equipment breakdowns and power outages were unavoidable.

The overall sample recovery rate indicates that the appropriate procedures and equipment are in place to assure reliable program implementation.

E.

Program Changes Harshaw TLD100 chip was removed as environmental TLD because it contains natural Lithium which has a percentage of Li-6. When Li-6 is in a neutron field, the Li-6 responds to the neutrons and gives a gamma over-response. Neutron dose is already handled in a different manner using TLD's that are calibrated correctly to respond to neutrons. Thus the Environmental TLD type was changed to Panasonic 814's that do not contain the natural Li in the TLD chips, but are suitable to measure the same dose range as proven by a study conducted and over 1 year of data was obtained to compare responses.

6

IV.

Results and Discussion A.

Aquatic Environment

1.

Public Water Samples were taken weekly and composited monthly at four locations (Z-14, Z-15, Z-16 and Z-18). The following analyses were performed.

Gross Beta Samples from all locations were analyzed for concentrations of gross beta (Table C-1.1, Appendix C). Gross beta was detected in 30 of 48 samples. The values ranged from 2.1 pCi/I to 4.7 pCi/I.

Concentrations detected were consistent with those detected in previous years (Figures C-1 and C-2, Appendix C).

Tritium Quarterly composites of weekly collections were analyzed for tritium activity (Table C-1.2, Appendix C). No tritium was detected and the LLD was met (Figures C-3 and C-4, Appendix C).

Gamma Spectrometry Samples from both locations were analyzed for gamma-emitting nuclides (Table C-1.3, Appendix C). No nuclides were detected and all required LLDs were met.

2.

Fish Fish samples comprised of white sucker, northern pike, common carp, brown trout, lake trout, and burbot were collected at two locations (Z-26 and Z-27) semiannually. The following analysis was performed:

Gamma Spectrometry The edible portion of fish samples from both locations was analyzed for gamma-emitting nuclides (Table C-11.1, Appendix C).

No nuclides were detected and all required LLDs were met.

3.

Sediment Aquatic sediment samples were collected at one location (Z-25) semiannually. The following analysis was performed:

7

Gamma Spectrometry Sediment samples from Z-25 were analyzed for gamma-emitting nuclides (Table C-111.1, Appendix C). No nuclides were detected and all required LLDs were met.

B.

Atmospheric Environment

1.

Airborne

a.

Air Particulates Continuous air particulate samples were collected from three locations on a weekly basis. The three locations were within the ZNPS site boundary (Z-01, Z-02 and Z-03). The following analyses were performed:

Gross Beta Weekly samples were analyzed for concentrations of beta emitters (Table C-IV.1 and C-IV.2, Appendix C).

Detectable gross beta activity was observed at all locations.

Comparison of results among the three groups aid in determining the effects, if any, resulting from the operation of ZNPS. The results from the On-Site locations ranged from 6E-3 pCi/m3 to 30E-3 pCi/m3 with a mean of 14E-3 pCi/m3. The results from the Control location ranged from

?E-3 pCi/m3 to 35E-3 pCi/m3 with a mean of 16E-3 pCi/m3.

Comparison of the 2016 air particulate data with previous year's data indicate no effects from the operation of ZNPS.

Concentrations detected were consistent with those detected in previous years.

Gamma Spectrometry Weekly samples were composited quarterly and analyzed for gamma-emitting nuclides (Table C-IV.3, Appendix C).

No plant-related nuclides were detected and all required LLDs were met. Naturally occurring Be-7 was detected; the source of this is described later in this report.

C.

Terrestrial Environment

1. Food Product Food product samples were collected at three locations (Z-Control, Z-Quad 3 and Z-Quad 4) when available. The following analysis was performed:

8

Gamma Spectrometry Samples from all locations were analyzed for gamma-emitting nuclides (Table C-V.1, Appendix C). No nuclides were detected and all required LLDs were met.

D.

Ambient Gamma Radiation Ambient gamma radiation levels were measured utilizing Harshaw (CaF and LiF) thermoluminescent dosimeters. Sixty-four TLD locations were hanging at 30 locations around the site. Results of TLD measurements are listed in Tables C-Vl.1 to C-Vl.3, Appendix C.

Most TLD measurements were below 25 mR/quarter, with a range of 13 mR/quarter to 50 mR/quarter.

E.

Land Use Survey A Land Use Census conducted during August 2016 around the Zion Nuclear Power Station (ZNPS) was performed by Zion Station Personnel for ZS to comply with Chapter 3 of the Zion Offsite Dose Calculation Manual. The purpose of the survey was to document the nearest resident, milk producing animal and garden of greater than 500 fb in each of the sixteen 22 % degree sectors around the site. The results of this survey are summarized below:

Sector N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Distance in Miles from ZS Residence Garden Miles Miles 2.5 3.4 1.9 1.1 1.0 1.1 1.0 1.0 1.3 9

>10 4.8 3.0 2.9 2.7 3.2 3.5 Milk Farm Miles

>10

>10

>10

>10

>10

>10

>10

>10

Source: Ill. Department of agriculture and USGS recommended using google maps to locate garden areas due to gardens and milk animals are voluntary declarations, also aerial photographs on ARCGIS layers updated by government sources are 5-10 years old.

Gardens located using Google Maps to narrow down areas that appeared to have been ploughed by aerial photographs, then visually verified by visiting locations.

Milk-producing animal located by internet search for dairies advertising selling milk for public consumption.

F.

Errata Data There is no errata data for 2016.

G.

Summary of Results - Inter-Laboratory Comparison Program The primary and secondary laboratories analyzed Performance Evaluation (PE) samples of air particulate, air iodine, milk, soil, vegetation and water matrices for (Appendix D). The PE samples, supplied by Analytics Inc., Environmental Resource Associates (ERA) and DOE's Mixed Analyte Performance Evaluation Program (MAPEP), were evaluated against the following pre-set acceptance criteria:

1.

Analytics Evaluation Criteria Analytics' evaluation report provides a ratio of laboratory results and Analytics' known value. Since flag values are not assigned by Analytics, TBE-ES evaluates the reported ratios based on internal QC requirements, which are based on the DOE MAPEP criteria.

2.

ERA Evaluation Criteria ERA's evaluation report provides an acceptance range for control and warning limits with associated flag values. ERA's acceptance limits are established per the USEPA, National Environmental Laboratory Accreditation Conference (NELAC), state-specific performance testing (PT) program requirements or ERA's SOP for the Generation of Performance Acceptance Limits, as applicable.

The acceptance limits are either determined by a regression equation specific to each analyte or a fixed percentage limit promulgated under the appropriate regulatory document.

3.

DOE Evaluation Criteria MAPEP's evaluation report provides an acceptance range with associated flag values.

10

The MAPEP defines three levels of performance: Acceptable (flag= "A"), Acceptable with Warning (flag= "W"), and Not Acceptable (flag = "N"). Performance is considered acceptable when a mean result for the specified analyte is +/- 20% of the reference value. Performance is acceptable with warning when a mean result falls in the range from +/-20% to +/-30% of the reference value (i.e., 20% <bias< 30%). If the bias is greater than 30%, the results are deemed not acceptable.

For the TBE laboratory, 156 out of 160 analyses performed met the specified acceptance criteria. Four analyses (Milk - Sr-90, Vegetation -

Sr-90, and Water - H-3 samples) did not meet the specified acceptance criteria for the following reasons and were addressed through the TBE Corrective Action Program.

Note: The Department of Energy (DOE) Mixed Analyte Performance Evaluation Program (MAPEP) samples are created to mimic conditions found at DOE sites which do not resemble typical environmental samples obtained at commercial nuclear power facilities.

1.

Teledyne Brown Engineering's MAPEP March 2016 air particulate cross check sample is now being provided to TBE by Analytics.

MAPEP's policy is to evaluate as failed non reported nuclides that were reported in the previous study. Since the Sr-90 was reported in the previous MAPEP study but not in this study MAPEP evaluated the Sr-90 for Soil as failed. NCR 16-14 The MAPEP March 2016 Sr-90 in vegetation was evaluated as failing a false positive test. In reviewing the data that was reported vs the data in LIMS, it was found that the error was incorrectly reported as 0.023 rather than the correct value of 0.230. If the value had been reported with the activity and correct uncertainty of 0.301 +/- 0.230, MAPEP would have evaluated the result as acceptable. NCR 16-14

2.

Teledyne Brown Engineering's Analytics' March 2016 milk Sr-90 result of 15 +/-.125 pCi/L was higher than the known value of 11.4 pCi/L with a ratio of 1.32. The upper ratio of 1.30 (acceptable with warning) was exceeded. After an extensive review of the data it is believed the technician did not rinse the filtering apparatus properly and some cross contamination from one of the internal laboratory spike samples may have been transferred to the analytics sample. We feel the issue is specific to the March 2016 Analytics sample. NCR 16-26

3.

Teledyne Brown Engineering's ERA November 2016 sample for H-3 in water was evaluated as failing. A result of 918 pCi/L was reported incorrectly due to a data entry issue. If the correct value 11

of 9180 had been reported, ERA would have evaluated the result as acceptable. NCR 16-34

4.

Teledyne Brown Engineering's Analytics' December 2016 milk Sr-90 sample result of 14.7 +/-.26 pCi/L was higher than the known value of 10 pCi/L with a ratio of 1.4 7. The upper ratio of 1.30 (ac~eptable with warning) was exceeded. The technician entered the wrong aliquot into the LIMS system. To achieve a lower error term TBE uses a larger aliquot of 1.2L (Normally we use.6L for client samples). If the technician had entered an aliquot of 1.2L into the LIMS system, the result would have been 12.2 pCi/L, which would have been considered acceptable. NCR 16-35 For the EIML laboratory, 198 of 203 analyses met the specified acceptance criteria. Five analyses (Water-Ba-133, Co-57; Soil - Ni-63, U-233/234, U-238) did not meet the specified acceptance criteria for the following reasons:

1.

The Environmental Inc., Midwest Laboratory's ERA April 2016 water Ba-133 result of 65.2 pCl/L was higher than the known value of 58.8 pCi/L, exceeding the upper control limit of 64.9 pCi/L. The reanalysis result of 57.8 pCl/L fell within acceptance criteria.

2.

The Environmental Inc., Midwest Laboratory's MAPEP February 2016 water Co-57 result of 1.38 Bq/L sample was higher than the known value of 0.00 Bq/L sample. This sample is considered a false positive.

3.

The Environmental Inc., Midwest Laboratory's MAPEP August 2016 soil Ni-60 result of 648 Bq/kg was lower than the known value of 990 Bq/kg, exceeding the lower control limit of 693 Bq/kg.

Reanalysis with a smaller aliquot resulted in acceptable results. An investigation is in process to identify better techniques for analyzing samples with complex matrices.

4.

The Environmental Inc., Midwest Laboratory's MAPEP August 2016 soil U-233/234 result of 46.8 Bq/kg was lower than the known value of 122 Bq/kg, exceeding the lower control limit of 85 Bq/kg.

MAPEP states that samples contain two fractions of Uranium; one that is soluble in concentrated HN03 and HCL acid and one that is "fundamentally insoluble in these acids". They also state that HF treatment cannot assure complete dissolution. Results are consistent with mea~uring the soluble form.

5.

The Environmental Inc., Midwest Laboratory's MAPEP August 2016 soil U-238 result of 46.6 Bq/kg was lower than the known value of 121 Bq/kg, exceeding the lower control limit of 85 Bq/kg.

MAPEP states that samples contain two fractions of Uranium; one 12.

that is soluble in concentrated HN03 and HCL acid and one that is "fundamentally insoluble in these acids". They also state that HF treatment cannot assure complete dissolution. Results are consistent with measuring the soluble form.

The Inter-Laboratory Comparison Program provides evidence of "in control" counting systems and methods, and that the laboratories are producing accurate and reliable data.

13

Intentionally left blank

APPENDIX A RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT

SUMMARY

TABLE A-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM ANNUAL

SUMMARY

FOR THE ZION NUCLEAR POWER STATION, 2016 Name of Facility:

ZION NUCLEAR POWER STATION DOCKET NUMBER:

50-295 & 50-304 Location of Facility:

ZION,IL REPORTING PERIOD:

2016 INDICATOR CONTROL MEDIUM OR REQUIRED LOCATIONS LOCATION LOCATION WITH HIGHEST ANNUAL MEAN (M)

NUMBER OF PATHWAY SAMPLED TYPES OF NUMBER OF LOWER LIMIT MEAN (M)

MEAN(M)

MEAN(M)

STATION#

NON ROUTINE (UNITOF ANALYSIS ANALYSIS OF DETECTION (F)

(F)

(F)

NAME REPORTED MEASUREMENT)

PERFORMED PERFORMED (LLD)

RANGE RANGE RANGE DISTANCE AND DIRECTION MEASUREMENTS PUBLIC WATER GR-B 48 4

3 3

3.1 Z-15 INDICATOR 0

(PCl/LITER)

(25136)

(8112)

(8112)

LAKE COUNTY WATER WORKS 2.1-4.7 2.2-3.5 2.3-3.8 1.4 MILES NNW OF SITE H-3 16 200

<LLD

<LLD 0

GAMMA 48 MN-54 15

<LLD

<LLD 0

C0-58 15

<LLD

<LLD 0

l>

FE-59 30

<LLD

<LLD 0

I

...lo.

C0-60 15

<LLD

<LLD 0

ZN-65 30

<LLD

<LLD 0

NB-95 15

<LLD

<LLD 0

ZR-95 15

<LLD

<LLD 0

CS-134 15

<LLD

<LLD 0

CS-137 18

<LLD

<LLD 0

BA-140 NA

<LLD

<LLD 0

LA-140 NA

<LLD

<LLD 0

FISH GAMMA 2

(PCllKG WET)

MN-54 130

<LLD NA 0

C0-58 130

<LLD NA 0

FE-59 260

<LLD NA 0

C0-60 130

<LLD NA 0

ZN-65 260

<LLD NA 0

NB-95 NA

<LLD NA 0

ZR-95 NA

<LLD NA 0

CS-134 100

<LLD NA 0

CS-137 100

<LLD NA 0

BA-140 NA

<LLD NA 0

LA-140 NA

<LLD NA 0

(M) The Mean Values are calculated using the positive values. (F) Fraction of detectable measurement are indicated in parentheses.

TABLE A-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM ANNUAL

SUMMARY

FOR THE ZION NUCLEAR POWER STATION, 2016 Name of Facility:

ZION NUCLEAR POWER STATION DOCKET NUMBER:

50-295 & 50-304 Location of Facility:

ZION.IL REPORTING PERIOD:

2016 INDICATOR CONTROL MEDIUM OR REQUIRED LOCATIONS LOCATION LOCATION WITH HIGHEST ANNUAL MEAN (M)

NUMBER OF PATHWAY SAMPLED TYPES OF NUMBER OF LOWER LIMIT MEAN(M)

MEAN(M)

MEAN (M)

STATION#

NONROUTINE (UNITOF ANALYSIS ANALYSIS OF DETECTION (F)

(F)

(F)

NAME REPORTED MEASUREMENT)

PERFORMED PERFORMED (LLD)

RANGE RANGE RANGE DISTANCE AND DIRECTION MEASUREMENTS SEDIMENT GAMMA 2

(PCllKG DRY)

MN-54 NA

<LLD NA 0

C0-58 NA

<LLD NA 0

FE-59 NA

<LLD NA 0

C0-60 NA

<LLD NA 0

ZN-65 NA

<LLD NA 0

NB-95 NA

<LLD NA 0

ZR-95 NA

<LLD NA 0

)>

CS-134 150

<LLD NA 0

I I\\)

CS-137 180

<LLD NA 0

BA-140 NA

<LLD NA 0

LA-140 NA

<LLD NA 0

AIR PARTICULATE GR-B 208 10 14 16 16 Z-13 CONTROL 0

(E-3 PC/ICU.METER)

(154/156)

(52/52)

(52/52)

OFFSITE CONTROL 6-30 7-35 7-35 10.0 MILES NW OF SITE GAMMA 16 MN-54 NA

<LLD

<LLD 0

C0-58 NA

<LLD

<LLD 0

FE-59 NA

<LLD

<LLD 0

C0-60 NA

<LLD

<LLD 0

ZN-65 NA

<LLD

<LLD 0

NB-95 NA

<LLD

<LLD 0

ZR-95 NA

<LLD

<LLD 0

CS-134 10

<LLD

<LLD 0

CS-137 10

<LLD

<LLD 0

BA-140 NA

<LLD

<LLD 0

LA-140 NA

<LLD

<LLD 0

(M) The Mean Values are calculated using the positive values. (F) Fraction of detectable measurement are indicated in parentheses.

)>

I

~

Name of Facility:

Location of Facility:

MEDIUM OR PATHWAY SAMPLED (UNITOF MEASUREMENT)

VEGETATION (PCllKGWET)

DIRECT RADIATION (MILL/-ROENTGEN!QTR.)

TABLE A-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM ANNUAL

SUMMARY

FOR THE ZION NUCLEAR POWER STATION, 2016 ZION NUCLEAR POWER STATION ZION,IL REQUIRED TYPES OF NUMBER OF LOWER LIMIT ANALYSIS ANALYSIS OF DETECTION PERFORMED PERFORMED (LLD)

GAMMA 7

MN-54 NA C0-58 NA FE-59 NA C0-60 NA ZN-65 NA NB-95 NA ZR-95 NA CS-134 60 CS-137 80 BA-140 NA LA-140 NA TLD-QUARTERL Y 256 NA INDICATOR LOCATIONS MEAN (M)

(F)

RANGE

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD 19.8 (232/232) 13-50 DOCKET NUMBER:

50-295 & 50-304 REPORTING PERIOD:

2016 CONTROL LOCATION MEAN(M)

(F)

RANGE

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD 18.1 (24/24) 15-21 LOCATION WITH HIGHEST ANNUAL MEAN (M)

MEAN (M)

(F)

RANGE 41.5 (414) 28-50 STATION#

NAME DISTANCE AND DIRECTION Z-131-1 INDICATOR 0.2MllESWSW (M) The Mean Values are calculated using the positive values. (F) Fraction of detectable measurement are indicated in parentheses.

NUMBER OF NONROUTINE REPORTED MEASUREMENTS 0

0 0

0 0

0 0

0 0

0 0

0

APPENDIX 8 LOCATION DESIGNATION, DISTANCE & DIRECTION, AND SAMPLE COLLECTION & ANALYTICAL METHOD

TABLE B-1:

Radiological Environmental Monitoring Program - Sampling Locations, Distance and Direction, Zion Nuclear Power Station, 2016 Location Location Description A.

Public Water Z-14 Z-15 Z-16 Z-18 Kenosha Water Works (control)

Lake County Water Works (indicator)

Waukegan Water Works (indicator)

Lake Forest Water Works (control)

B.

Air Particulates Z-01 Z-02 Z-03 Z-13 C.

Fish Z-26 Z-27 D.

Sediment Z-25 Onsite 1 (indicator)

Onsite 2 (indicator)

Onsite 3 (indicator)

Offsite Control Lake Michigan Nearsite (indicator)

Lake Michigan Farsite (indicator)

Lake Michigan, Illinois Beach State Park (indicator)

E.

Environmental Dosimetrv - TLD Inner Ring Z-101-1 and -2 Z-102-1 and ~2 Z-103-1 and -2 Z-104-1 and -2 Z-105-1 and -2 Z-106-1 and -2 Z-107-1 and -2 Z-108-1 and -2 Z-110-1 and -2 Z-111-1 and-2 Z-112-1 and -2 Z-113-1 and -2 Z-114-1 and -2 Z-115-1 and -2 Z-121-1 and -2 Z-124-1 and -2 Z-125-1 and -2 Other Z-01-1 and -2 Z-02-1 and -2 Z-03-1 and -2 Outer Ring Z-209-1 and -2 Z-211-1 and -2 Z-212-1 and -2 Z-213-1 and -2 Z-214-1 and -2 Z-215-1 and -2 Z-216-1 and -2 Control Z-13-1 thru -6 Onsite 1 (indicator)

Onsite 2 (indicator)

Onsite 3 (indicator)

Distance & Direction From Site 10.0 miles N 1.4 miles NNW 6.1 miles S 12.9 miles S 0.3 miles S 0.2 miles W 0.2 miles NNW 10 miles NW At station 10.1 miles N 0.2 miles S 0.2 miles N 0.2 miles NNE 0.2 miles NE 0.1 miles ENE 0.1 miles E 0.1 miles ESE 0.1 miles SE 0.1 miles SSE 0.2 miles SSW 0.3 miles SW 0.7 miles WSW 0.6miles W 0.6milesWNW 0.4 miles NW 0.2 miles NNW 0.5miles SW 0.4 miles SSW 0.3 miles S 0.2 milesW 0.2 miles NNW 5.1 miles S 4.7milesSW 5.1 miles WSW 5.1 miles W 4.6milesWNW 4.0miles NW 10 miles NW

TABLE B-2:

Sample Medium Public Water Public Water Public Water Fish Sediment Air Particulates Air Particulates TLD Radiological Environmental Monitoring Program - Summary of Sample Collection and Analytical Methods, Zion Nuclear Power Station, 2016 Analysis Sampling Method Analytical Procedure Number TBE, TBE-2007 Gamma emitting radioisotope analysis Gamma Monthly composite from Spectroscopy weekly grab samples.

Env. Inc., GS-01 Determination of gamma emitters by gamma spectroscopy TBE, TBE-2008 Gross Alpha and/or gross beta activity in Gross Beta Monthly composite from various matrices weekly grab samples.

Env. Inc., W(DS)-01 Determination of gross alpha and/or gross beta in water (dissolved solids or total residue)

TBE, TBE-2011 Tritium analysis in drinking water by liquid Tritium Quarterly composite from scintillation weekly grab samples.

Env. Inc., T-02 Determination of tritium in water (direct method)

Gamma Semi-annual samples TBE-2007 Gamma emitting radioisotope analysis Spectroscopy collected via electroshocking or other Env. Inc., GS-01 Determination of gamma emitters by gamma techniques spectroscopy Gamma Semi-annual grab TBE, TBE-2007 Gamma emitting radioisotope analysis Spectroscopy samples Env. Inc., GS-01 Determination of gamma emitters by gamma spectroscopy One-week composite of TBE, TBE-2008 Gross Alpha and/or gross beta activity in Gross Beta continuous air sampling various matrices through glass fiber filter Env. Inc., AP-02 Determination of gross alpha and/or gross paper beta in air particulate filters Gamma Quarterly composite of TBE, TBE-2007 Gam~a emitting radioisotope analysis Spectroscopy each station Env. Inc., GS-01 Det~rmination of gamma emitters by gamma spectroscopy i

Quarterly TLDs I

Thermoluminesce comprised of two CaF Mirian Technologies nee Dosimetry 200 and two LiF 100 LiF 4-chip Harshaw elements.

Figure B-1 Inner Ring TLD and Fixed Air Sampler Locations of the Zion Nuclear Power Station, 2016

165 I

I OP HARBO Figure 8-2 Outer Ring TLD and Fixed Air Sampler Locations of the Zion Nuclear Power Station, 2016

Racine Kenosha V. acer V.orl.: ~

Z-14

  • z_:.7 I

Wisconsin l " -------"i~;. -. -. -. -. ------- :~ ~~;.

\\

~--

WaterWoiis llinoi.1' Beach State Park Z-15 l

~ ukegan *1 Z-16 Water Wodr.s

~orth Chicago Lake Forest V. a.ter '\\\\ oih

  • Sampling Locations --------~----

Figure 8-3

\\

LAKE MICIIlGAN Fish, Water and Sediment Sampling Locations of the Zion Nuclear Power Station, 2016

APPENDIXC DATA TABLES AND FIGURES PRIMARY LABORATORY

Table C-1.1 Concentrations of Gross Beta in Public Water Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Results in Units of pCi/liter +/- 2 Sigma COLLECTION PERIOD Z-14 Z-15 Z-16 Z-18 01/06/16 - 01/27/16

< 2.0 3.7 +/- 1.8

< 2.0

< 2.0 02/03/16 - 02/24/16 4.7 +/- 1.7 3.1 +/- 1.5 3.2 +/- 1.5 3.3 +/- 1.5 03/02/16 - 03/30/16 3.5 +/- 1.6 2.3 +/- 1.4 3.2 +/- 1.5 2.7 +/- 1.5 04/06/16 - 04/27/16

< 1.6 3.1 +/- 1.5 2.2 +/- 1.4

< 2.0 05/04/16 - 05/25/16 2.8 +/- 1.5

< 2.1 3.4 +/- 1.6 3.3 +/- 1.6 06/01 /16 - 06/29/16 2.1 +/- 1.4

< 2.0

< 2.0

< 2.0 07/06/16 - 07/27/16

< 2.5

< 2.5

< 2.5 2.9 +/- 1.9 08/03/16 - 08/31 /16

< 2.1

< 2.2 2.4 +/- 1.5

< 2.2 09/07 /16 - 09/28/16 3.5 +/- 1.4 2.4 +/- 1.3 2.3 +/- 1.3 3.5 +/- 1.4 10/05/16 - 10/27 /16 2.6 +/- 1.5 2.7 +/- 1.5 3.6 +/- 1.8 3.2 +/- 1.6 11/03/16 - 11/30/16 2.8 +/- 1.3 3.7 +/- 1.4 2.7 +/- 1.3 2.9 +/- 1.3 12/07 /16 - 12/29/16 2.1 +/- 1.3 3.8 +/- 1.5 2.5 +/- 1.3 2.2 +/- 1.3 MEAN +/- 2 STD DEV 3.0 +/- 1.8 3.1 +/- 1.2 2.8 +/- 1.1 3.0 +/- 0.9 Table C-1.2 Concentrations of Tritium in Public Water Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 COLLECTION PERIOD 01 /06/16 - 03/30/16 04/06/16 - 06/29/16 07/06/16 - 09/28/16 10/05/16 - 12/29/16 MEAN Results in Units of pCi/liter +/- 2 Sigma Z-14 Z-15 Z-16

< 197

< 197

< 196

< 182

< 181

< 180

< 182

< 180

< 178

< 197

< 197

< 197 Z-18

< 192

< 184

< 181

< 194 THE MEAN AND TWO STANDARD DEVIATION ARE CALCULATED USING THE POSITIVE VALUES C-1

0,,

N Table C-1.3 SITE COLLECTION PERIOD Z-14 01/06/16 - 01/27/16 02/03/16 - 02/24/16 03/02/16 - 03/30/16 04/06/16 - 04/27/16 05/04/16 - 05/25/16 06/01/16 - 06/29/16 07 /06/16 - 07 /27 /16 08/03/16 - 08/31/16 09/07 /16 - 09/28/16 10/05/16 - 10/27 /16 11/03/16 - 11/30/16 12/07/16 - 12/29/16 MEAN Z-15 01/06/16 - 01/27/16 02/03/16 - 02/24/16 03/02/16 - 03/30/16 04/06/16 - 04/27/16 05/04/16 - 05/25/16 06/01 /16 - 06/29/16 07/06/16 - 07/27/16 08/03/16 - 08/31/16 09/07 /16 - 09/28/16 10/05/16 - 10/27 /16 11/03/16 - 11/30/16 12/07 /16 - 12/29/16 MEAN Concentrations of Gamma Emitters in Public Water Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Results in Units of pCi/liter +/- 2 Sigma Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140

< 6 7

< 6

< 8

< 4

< 8

< 2

< 6

< 6 8

< 8

< 6

< 6

< 6

< 7 5

< 5

< 5

< 2

< 6

< 7

< 5 7

< 6

< 6

< 6

< 5

< 8

< 5

< 7

< 2

< 8

< 8

< 7

< 9

< 6

< 7

< 7

< 7

< 6

< 5

< 7

< 2

< 5

< 6

< 8

< 7

< 6

< 11

< 13

< 13

< 17

< 11

< 24

< 5

< 14

< 7

< 16

< 14

< 12

< 13

< 14

< 16

< 10

< 11

< 16

< 5

< 16

< 14

< 17

< 17

< 13

< 6

< 7

< 9 7

< 5

< 11

< 2

< 5

< 8

< 6

< 6

< 6

< 7 7

7 5

< 5

< 7

< 2

< 5

< 6

< 7

< 6

< 6

< 12

< 13

< 11

< 14

< 9

< 15

< 3

< 14

< 12

< 13

< 17

< 13

< 12

< 17

< 14

< 11

< 11

< 11

< 4

< 14

< 14

< 15

< 13

< 12

< 5

< 8

< 5

< 8

< 6

< 8

< 2

< 9

< 9

< 8

< 9 7

< 8

< 7

< 7 5

< 6

< 8

< 2

< 8

< 9 8

< 6

< 7

< 10

< 15

< 11

< 14

< 10

< 14

< 4

< 14

< 15

< 15

< 12

< 11

< 12

< 10

< 14

< 10

< 10

< 13

< 4

< 14

< 11

< 15

< 14

< 13

< 6

< 6

< 6

< 7

< 4

< 7 2

< 6

< 6

< 6

< 5 5

< 6

< 6

< 7

< 4

< 5 7

< 2 5

7

< 9

< 7 5

< 4 7

< 6

< 9

< 5

< 8

< 2 7

5

< 7

< 8

< 6

< 6

< 7

< 7

< 6 5

7

< 2

< 6

< 6

< 7

< 7

< 5

< 35

< 38

< 53

< 59

< 59

< 66

< 25

< 55

< 46

< 63

< 48

< 48

< 45

< 40

< 46

< 38

< 58

< 46

< 25

< 44

< 52

< 77

< 45

< 55

< 10

< 16

< 15

< 17

< 20

< 15

< 9

< 15

< 14

< 20

< 16

< 16

< 13

< 15

< 13

< 12

< 16

< 14

< 7

< 17

< 16

< 22

< 17

< 10

0 I

~

Table C-1.3 SITE COLLECTION PERIOD Z-16 1/6/2016 - 01/27/16 2/3/2016 - 02/24/16 3/2/2016 - 03/30/16 4/6/2016 - 04/27 /16 5/4/2016 - 05/25/16 06/01 /16 - 06/29/16 07/06/16 - 07/27/16 08/03/16 - 08/31/16 09/07/16 - 09/28/16 10/05/16 - 10/27 /16 11/03/16 - 11/30/16 12/07/16 - 12/29/16 MEAN Z-18 01/06/16 - 01/27/16 02/03/16 - 02/24/16 03/02/16 - 03/30/16 04/06/16 - 04/27/16 05/04/16 - 05/25/16 06/01 /16 - 06/29/16 07/06/16 - 07/27/16 08/03/16 - 08/31/16 09/07 /16 - 09/28/16 10/05/16 - 10/27 /16 11 /03/16 - 11 /30/16 12/07/16 - 12/29/16 MEAN Concentrations of Gamma Emitters in Public Water Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Results in Units of pCi/liter +/- 2 Sigma Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140

< 7

< 6 8

< 6

< 4

< 4

< 2

< 6

< 6

< 7

< 7

< 8

< 6 8

< 2 5

< 2

< 6

< 2

< 6 7

< 6

< 7

< 4

< 7

< 6

< 7

< 6

< 6

< 7

< 2

< 6

< 8

< 6

< 7

< 7

< 3

< 7

< 2

< 7

< 3

< 6

< 2

< 7

< 9

< 6

< 7

< 6

< 13

< 11

< 16

< 11

< 10

. < 14

< 6

< 14

< 19

< 14

< 20

< 16

< 20

< 16

< 5

< 14

< 6

< 13

< 5

< 14

< 16

< 14

< 16

< 13

< 8 5

8 5

3

< 5

< 2

< 7

< 6

< 7

< 8

< 7

< 6

< 7

< 2

< 8

< 2

< 8

< 2

< 6

< 7 7

< 7

< 6

< 13

< 11

< 15

< 10 8

< 11

< 4

< 10

< 15

< 13

< 20

< 14

< 7

< 6 8

7

< 5

< 6

< 3

< 9

< 8

< 8

< 9

< 9

< 15

< 10

< 15

< 10 4

3

< 15 6

5 3

< 12

< 7 4

- < 2

< 11 6

< 11 8

< 13 8

< 16

< 8

< 10

< 7

< 12

< 12

< 15

< 12

< 10

< 10 5

< 14

< 15

< 14

< 14

< 14

< 14

< 11

< 4

< 14

< 5

< 12

< 4

< 12

< 13

< 15

< 14

< 11

< 6

< 6

< 7

< 6

< 4

< 5

< 2

< 6

< 7

< 8

< 9

< 8

< 6

< 7

< 2

< 6

< 2

< 6

<-2

< 5

< 7

< 6

< 8

< 6

< 7

< 6

< 7

< 6

< 5

< 6

< 2

< 7

< 7

< 7

< 9

< 8

< 7

< 9

< 2

< 6

< 2 7

< 2

< 7

< 8 7

< 8

< 6

< 44

< 34

< 49

< 47

< 54

< 35

< 31

< 49

< 45

< 53

< 41

< 72

< 55

< 40

< 16

< 42

< 27

< 42

< 25

< 37

< 49

< 60

< 50

< 53

< 14

< 9

< 15

< 15

< 18

< 10

< 9

< 15

< 14

< 30

< 15

< 19

< 17

< 12

< 5

< 11

< 9

< 15

< 8

< 13

< 12

< 20

< 17

< 18

Table C-11.1 Concentrations of Gamma Emitters in Fish Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Results in Units of pCi/kg Wet+/- 2 sigma COLLECTION SITE PERIOD Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140 Z-26 (Predator)

Northern Pike 05/24/16

< 43

< 37

< 101

< 36

< 101

< 34

< 68

< 45

< 50

< 236

< 65 White Sucker 05/24/16

< 53

< 45

< 125

< 47

< 111

< 55

< 85

< 52

< 50

< 229

< 51 Brown Trout 10/27/16

< 81

< 73

< 161

< 72

< 119

< 75

< 143

< 71

< 83

< 467

< 114 Common Carp 10/27/16

< 42

< 41

< 80

< 44

< 85

< 47

< 61

< 32

< 36

< 293

< 96 MEAN Z-27 (Predator)

Burbot 05/13/16

< 39

< 41

< 108

< 34

< 82

< 44

< 61

< 35

< 46

< 347

< 103 Lake Trout 05/13/16

< 39

< 44

< 103

< 36

< 90

< 48

< 87

< 38

< 48

< 395

< 72 0

Burbot 10/26/16

< 72

< 76

< 174

< 68

< 153

< 78

< 139

< 67

< 69

< 510

< 173

~

Lake Trout 10/26/16

< 59

< 59

< 119

< 54

< 151

< 61

< 103

< 83

< 63

< 375

< 117 MEAN

0 I

C11 Table C-111.1 SITE Z-25 COLLECTION PERIOD 05/12/16 10/19/16 MEAN Mn-54

< 37

< 45 Concentrations of Gamma Emitters in Sediment Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Co-58

< 30

< 46 Fe-59

< 85

< 104 Results in Units of pCi/kg Dry + 2 sigma Co-60

< 29

< 44 Zn-65

< 83

< 101 Nb-95

< 40

< 64 Zr-95

< 65

< 92 Cs-134

< 32

< 40 Cs-137

< 31

< 46 Ba-140

< 211

< 267 la-140

< 46

< 83

Table C-IV.1 Concentrations of Gross Beta in Air Particulate Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Results in Units of E-3 pCi/cu meter+/- 2 Sigma COLLECTION GROUP I I GROUP II PERIOD Z-01 Z-02 Z-03 Z-13 12/30/15 - 01/06/16 27 +/- 5 25 +/- 5 24 +/- 5 25 +/- 5 01/06/16 - 01/13/16 17 +/- 4 15 +/- 4 16 +/- 4 19 +/- 4 01/13/16 - 01/20/16 19 +/- 4 20 +/- 6 21 +/- 4 17 +/- 4 01/20/16 - 01/27/16 15 +/- 4 11 +/- 4 12 +/- 4 15 +/- 4 01/27/16 - 02/03/16 14 +/- 4 13 +/- 3 18 +/- 4 14 +/- 4 02/03/16 - 02/10/16 14 +/- 4 11 +/- 4 17 +/- 4 15 +/- 4 02/1 0/16 - 02/17 /16 15 +/- 4 12 +/- 4 15 +/- 4 19 +/- 4 02/17 /16 - 02/24/16 15 +/- 4 11 +/- 4 12 +/- 4 14 +/- 4 02/24/16 - 03/02/16 20 +/- 4 13 +/- 4 15 +/- 4 16 +/- 4 03/02/16 - 03/09/16 14 +/- 4 10 +/- 4 11 +/- 4 12 +/- 4 03/09/16 - 03/16/16 14 +/- 4 9 +/- 3 11 +/- 3 14 +/- 4 03/16/16 - 03/22/16 7 +/- 4 6 +/- 4 9 +/- 4 7+/-4 03/22/16 - 03/30/16 10 +/- 3 8 +/- 3 12 +/- 3 9 +/- 3 03/30/16 - 04/06/16 13 +/- 4 11 +/- 4 12 +/- 4 16 +/- 4 04/06/16 - 04/13/16 14 +/- 4 10 +/- 3 11 +/- 4 13 +/- 4 04/13/16 - 04/20/16 19 +/- 4 12 +/- 4 17 +/- 4 17 +/- 4 04/20/16 - 04/27/16 14 +/- 4 14 +/- 4 15 +/- 4 15 +/- 4 04/27/16 - 05/04/16 9 +/- 3 9 +/- 3 12 +/- 4 14 +/- 4 05/04/16 - 05/12/16 10 +/- 3 7 +/- 3 6 +/- 3 8 +/- 3 05/12/16 - 05/18/16 11 +/- 4 7 +/- 3 9 +/- 4 11 +/- 4 05/18/16 - 05/25/16 19 +/- 4 16 +/- 4 20 +/- 5 17 +/- 4 05/25/16 - 06/01/16 13 +/- 4 10 +/- 4 14 +/- 4 11 +/- 4 06/01/16 - 06/09/16 11 +/- 3 9 +/- 3 9 +/- 3 9 +/- 3 06/09/16 - 06/15/16 15 +/- 4 10 +/- 4 12 +/- 4 11 +/- 4 06/15/16 - 06/22/16 13 +/- 4 10 +/- 4 13 +/- 4 15 +/- 4 06/22/16 - 06/29/16 13 +/- 4 11 +/- 3 15 +/- 4 15 +/- 4 06/29/16 - 07 /06/16 14 +/- 4 12 +/- 4 13 +/- 4 13 +/- 4 07 /06/16 - 07 /14/16 16 +/- 3 13 +/- 3 14 +/- 3 15 +/- 3 07 /14/16 - 07 /20/16 11 +/- 4 8 +/- 4 11 +/- 4 11 +/- 4 07/20/16 - 07/27/16 17 +/- 4 12 +/- 4 18 +/- 4 16 +/- 4 07/27/16 - 08/03/16 14 +/- 4 11 +/- 4 12 +/- 4 15 +/- 4 08/03/16 - 08/10/16 16 +/- 4 15 +/- 3 21 +/- 4 19 +/- 4 08/10/16 - 08/18/16 17 +/- 4 14 +/- 4 19 +/- 4 18 +/- 4 08/18/16 - 08/24/16 9 +/- 4 7 +/- 4 11 +/- 5 7 +/- 4 08/24/16 - 08/31/16 17 +/- 4 15 +/- 4 11 +/- 4 14 +/- 4 08/31/16 - 09/07/16 13 +/- 4 13 +/- 4 17 +/- 4 12 +/- 4 09/07 /16 - 09/14/16 14 +/- 4 13 +/- 4 13 +/- 4 14 +/- 4 09/14/16 - 09/21/16 18 +/- 4 14 +/- 4 18 +/- 4 19 +/- 4 09/21/16 - 09/28/16 16 +/- 4 14 +/- 4 18 +/- 4 21 +/- 4 09/28/16 - 10/05/16 11 +/- 4 8 +/- 3 9 +/- 3 13 +/- 4 10/05/16 - 10/12/16 24 +/- 5 18 +/- 4 23 +/- 5 23 +/- 5 10/12/16 - 10/19/16 16 +/- 4 10 +/- 3 12 +/- 4 16 +/- 4 10/19/16 - 10/26/16 9 +/- 3

<6

<6 7 +/- 5 10/27/16 - 11/03/16 18 +/- 4 17 +/- 4 17 +/- 4 19 +/- 4 11/03/16 - 11/09/16 24 +/- 5 22 +/- 5 30 +/- 6 35 +/- 6 11/09/16 - 11/16/16 17 +/- 4 19 +/- 4 20 +/- 4 27 +/- 5 11/16/16 - 11/23/16 18 +/- 4 18 +/- 5 19 +/- 4 20 +/- 5 11/23/16 - 11/30/16 25 +/- 5 18 +/- 4 22 +/- 4 25 +/- 5 11/30/16 - 12/07/16 13 +/- 4 16 +/- 4 15 +/- 4 15 +/- 4 12/07/16 - 12/14/16 18 +/- 4 14 +/- 4 22 +/- 4 19 +/- 4 12/14/16 - 12/20/16 20 +/- 5 18 +/- 4 17 +/- 5 18 +/- 5 12/20/16 - 12/29/16 20 +/- 4 16 +/- 3 18 +/- 4 17 +/- 3 MEAN+/- 2 STD DEV 15 +/- 8 13 +/- 8 15 +/- 9 16 +/- 11 THE MEAN AND TWO STANDARD DEVIATION ARE CALCULATED USING THE POSITIVE VALUES C-6

Table C-IV.2 Monthly and Yearly Mean Values of Gross Beta Concentrations in Air Particulate Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Results in Units of E-3 pCi/cu meter+/- 2 Sigma GROUP 1-0NSITE LOCATIONS GROUP II - OFFSITE CONTROL LOCATION COLLECTION MIN MAX MEAN COLLECTION MIN MAX MEAN PERIOD

+/-2SD PERIOD

+/-2SD 12/30/15 - 02/03/16 11 27 18 +/- 10 12/30/15 - 02/03/16 14 25 18 +/- 8 02/03/16 - 03/02/16 11 20 14 +/- 5 02/03/16 - 03/02/16 14 19 16 +/- 4 03/02/16 - 03/30/16 6

14 10 +/- 5 03/02/16 - 03/30/16 7

14 10 +/- 6 03/30/16 - 05/04/16 9

19 13 +/- 6 03/30/16 - 05/04/16 13 17 15 +/- 4 05/04/16 - 06/01/16 6

20 12 +/- 9 05/04/16 - 06/01/16 8

17 12 +/- 8 06/01 /16 - 06/29/16 9

15 12 +/- 4 06/01/16 - 06/29/16 9

15 13 +/- 6 06/29/16 - 08/03/16 8

18 13 +/- 5 06/29/16 - 08/03/16 11 16 14 +/- 4 08/03/16 - 08/31/16 7

21 14 +/- 8 08/03/16 - 08/31/16 7

19 14 +/- 10 08/31 /16 - 09/28/16 13 18 15 +/- 5 08/31/16 - 09/28/16 12 21 16 +/- 9 09/28/16 - 11 /03/16 8

24 15 +/- 11 09/28/16 - 11/03/16 7

23 16 +/- 12 11/03/16 - 11/30/16 17 30 21 +/- 7 11/03/16 - 11/30/16 20 35 27 +/- 13 11/30/16 - 12/29/16 13 22 17 +/- 5 11/30/16 - 12/29/16 15 19 17 +/- 3 12/30/15 - 12/29/16 6

30 14 +/- 9 12/30/15 - 12/29/16 7

35 16 +/- 11 C-7

Table C-IV.3 Concentrations of Gamma Emitters in Air Particulate Samples Collected in the Vicinity of Zion Nuclear Power Station, 2016 Results in Units of E-3 pCi/cu meter + 2 Sigma COLLECTION SITE PERIOD Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140 Z-01 12/30/15 - 03/30/16 3

4

< 10 3

6 3

5 3

3

< 70

< 16 03/30/16 - 06/29/16 2

2 6

2 4

3 4

2 2

< 35

< 16 06/29/16 - 09/28/16 2

2 7

3 7

3 3

2 2

< 49

< 15 09/28/16 - 12/29/16 2

1 4

2 4

2 3

2 2

8 3

MEAN Z-02 12/30/15 - 03/30/16 3

3 8

2 7

3 6

3 2

< 59

< 18 03/30/16 - 06/29/16 2

2 7

2 5

2 3

2 2

< 49

< 22 06/29/16 - 09/28/16 2

3 7

3 4

3 5

3 2

< 50

< 27 09/28/16 - 12/29/16 3

< 4

< 11 4

7 4

7 3

3

< 14 6

MEAN 0

Z-03 12/30/15 - 03/30/16 4

5

< 10 3

< 10 5

8 5

3

< 86

< 32 I co 03/30/16 - 06/29/16 3

4 9

3 7

3 7

3 3

< 47

< 26 06/29/16 - 09/28/16 3

4 9

3 8

4 7

4 3

< 72

< 17 09/28/16 - 12/29/16 2

2 4

3 5

2 4

2 2

9 4

MEAN Z-13 12/30/15 - 03/30/16 2

3 9

2 6

3 5

2 2

< 58

< 20 03/30/16 - 06/29/16 5

5

< 12 4

8 6

7 3

3

< 83

< 37 06/29/16 - 09/28/16 2

3 9

3 8

3 5

3 3

< 63

< 25 09/28/16 - 12/29/16 2

2 5

3 5

2 5

3 2

< 12 4

MEAN

0 cO Table C-V.1 COLLECTION SITE PERIOD Z-CONTROL Carrots 09/01/16 Potatoes 09/01/16 Cabbage 09/08/16 MEAN Z-QUAD3 Cabbage 09/01/16 Potatoes 09/01/16 MEAN Z-QUAD4 Cabbage 09/01/16 Potatoes 09/01/16 MEAN Mn-54

< 15

< 18

< 16

< 14

< 10

< 20

< 18 CONCENTRATIONS OF GAMMA EMITTERS IN VEGETATION SAMPLES COLLECTED IN THE VICINITY OF ZION NUCLEAR POWER STATION, 2016 Co-58

< 17

< 14

< 16

< 14

< 11

< 21

< 18 Fe-59

< 37

< 35

< 41

< 33

< 25

< 40

< 40 RESULTS IN UNITS OF PC/KG WET + 2 SIGMA Co-60

< 19

< 18

< 15

< 13

< 8

< 25

< 15 Zn-65

< 39

< 41

< 41

< 32

< 26

< 36

< 46 Nb-95

< 19

< 16

< 17

< 16

< 14

< 25

< 21 Zr-95

< 29

< 33

< 36

< 25

< 22

< 35

< 30 Cs-134

< 14

< 15

< 16

< 13

< 10

< 15

< 24 Cs-137

< 15

< 16

< 19

< 12

< 10

< 17

< 17 Ba-140

< 112

< 107

< 102 92 77

< 137

< 108 La-140

< 38

< 25

< 19

< 24

< 19

< 45

< 32

Table C-Vl.1 Quarterly TLD Results for Zion Nuclear Power Station, 2016 Results in Units of Milli-Roentgen/Quarter+/- 2 Standard Deviations STATION MEAN CODE

+/-2S.D.

JAN-MAR APR-JUN JUL-SEP OCT-DEC Z-01 29 +/- 12 36 30 25 23 Z-02 18 +/- 7 22 18 17 14 Z-03 18 +/- 4 18 20 17 15 Z-13 19 +/- 3 19 19 20 17 Z-101 17 +/- 5 18 20 16 14 Z-102 19 +/- 5 21 19 19 15 Z-103 16 +/- 4 18 18 15 14 Z-104 16 +/- 2 17 17 16 15 Z-105 18 +/- 4 20 19 18 15 Z-106 18 +/- 5 20 20 17 15 Z-107 18 +/- 6 22 19 16 15 Z-108 21 +/- 3 22 21 20 19 Z-109 33 +/- 23 48 35 29 20 Z-112 18 +/- 3 19 19 18 16 Z-113 17 +/- 4 17 18 18 14 Z-114 17 +/- 3 17 19 17 15 Z-115 18 +/- 3 17 19 19 16 Z-121 16 +/- 5 17 19 15 13 Z-124 18 +/- 4 18 19 19 15 Z-125 19 +/- 3 20 19 19 17 Z-129 16 +/- 5 17 19 14 14 Z-130 20 +/- 5 22 22 19 17 Z-131 42 +/- 20 48 50 40 28 Z-209 18 +/- 5 18 17 21 15 Z-211 21 +/- 4 24 20 21 19 Z-212 22 +/- 5 23 25 21 19 Z-213 23 +/- 6 25 23 24 18 Z-214 19 +/- 3 19 19 21 17 Z-215 22 +/- 4 23 23 23 19 Z-216 18 +/- 3 18 20 19 16 C-10

Table C-Vl.2 MEAN QUARTERLY TLD RESULTS FOR INNER RING, OUTER RING, SPECIAL INTEREST, AND CONTROL STATIONS FOR ZION NUCLEAR POWER STATION, 2016 Table C-Vl.3 Results in Units of Milli-Roentgen/Quarter+/- 2 Standard Deviations of the Station Data COLLECTION PERIOD JAN-MAR APR-JUN JUL-SEP OCT-DEC LOCATION INNER RING OUTER RING OTHER

+/-2S.D.

23 +/- 19 20 +/- 5 17 +/- 2 22 +/- 14 21 +/- 5 19 +/- 2 20 +/- 12 22 +/- 5

18. +/- 3 17 +/- 8 18 +/- 3 15 +/- 2

SUMMARY

OF THE AMBIENT DOSIMETRY PROGRAM FOR ZION NUCLEAR POWER STATION, 2016 RESULTS IN UNITS OF MILLI-ROENTGEN/QUARTER SAMPLES PERIOD PERIOD ANALYZED MINIMUM MAXIMUM INNER RING 144 13 50 OUTER RING 56 15 25 SPECIAL INTEREST 32 14 21 CONTROL 24 15 21 CONTROL 18 +/- 2 19 +/- 2 20 +/- 2 16 +/- 2 PERIOD MEAN

+/-2 S.D.

20 +/- 15 20 +/- 5 17 +/- 4 18 +/- 4 INNER RING STATIONS - Z-01, Z-02, Z-03, Z-101, Z-102-1, Z-103-1, Z-104, Z-105, Z-106, Z-107, Z-108, Z-109, Z-121, Z-124, Z-125, Z-129, Z130, Z-131 SPECIAL INTEREST STATIONS-Z-112, Z-113, Z-114, Z-115 OUTER RING STATIONS - Z-209, Z-211, Z-212, Z-213, Z-214, Z-215, Z-216 CONTROL STATION - Z-13 C-11

FIGURE C-1 PUBLIC WATER - GROSS BETA - STATIONS Z-14 AND Z-15 COLLECTED IN THE VICINITY OF ZNPS, 2000 - 2016

....I B Cl.

! 0 Cl.

Z-14 (C) Kenosha Wate Works 5.0 4.0 3.0 2.0 1.0 0.0 -------.-------........-----..---------.

01-26-00 06-17-03 11-06-06 03-28-10 08-17-13 01-06-17 Z-15 Lake County Water Works 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 +-"----------------------

01-26-00 06-17-03 11-06-06 03-28-10 08-17-13 01-06-17 DUE TO VENDOR CHANGE IN 2005, <VALUES ARE LLD VALUES JANUARY THROUGH JUNE 2005 AND MDC VALUES AFTER JUNE 2005 C-12

FIGURE C-2 PUBLIC WATER - GROSS BETA - STATIONS Z-16 AND Z-18 COLLECTED IN THE VICINITY OF ZNPS, 2000 - 2016 Z-16 Waukegan Water Works 10.0 9.0 8.0 7.0 6.0

..J B 5.0 c..

4.0 3.0 2.0 1.0 0.0 01-26-00 06-17-03 11-06-06 03-28-10 08-17-13 01-06-17 Z-18 (C) Lake Forest Water Works 10.0 9.0 8.0 7.0 6.0

=:!

5.0 i:3 c..

4.0 3.0 2.0 1.0 0.0 01-26-00 06-17-03 11-06-06 03-28-10 08-17-13 01-06-17 DUE TO VENDOR CHANGE IN 2005, <VALUES ARE LLD VALUES JANUARY THROUGH JUNE 2005 AND MDC VALUES AFTER JUNE 2005 C-13

FIGURE C-3 PUBLIC WATER - TRITIUM - STATION Z-14 AND Z-15 COLLECTED IN THE VICINITY OF ZNPS, 2000 - 2016 s

0 c.

Z-14 (C) Kenosha Water Works 300 200 100 O-t--~~----,i---~~---~~~---i-~~~--t-~~----1 01-01-00 05-27-03 10-20-06 03-15-10 08-08-13 01-01-17 Z-15 Lake County Water Works 300 250 200

! 0 150
c.

100 50 0+-~~---1,--~~--+~~~-+-~~~+-~~--1 03-29-00 08-05-03 12-11-06 04-18-10 08-24-13 12-30-16 DUE TO VENDOR CHANGE IN 2005, <VALUES ARE LLD VALUES JANUARY THROUGH JUNE 2005 AND MDC VALUES AFTER JUNE 2005 C-14

FIGURE C-4 PUBLIC WATER -TRITIUM - STATION Z-16 AND Z-18 COLLECTED IN THE VICINITY OF ZNPS, 2000 - 2016 Z-16 Waukegan Water Works 250 200 150

! 0 a.

100 50 0

03-29-00 08-05-03 12-11-06 04-18-10 08-24-13 12-30-16 Z-18 (C) Lake Forest Water Works 250 200 150

..J B

a.

100 50 0+-><-~_,;_--1~~~-+-~~~-+-~~~+-~~---1 03-29-00 08-05-03 12-11-06 04-18-10 08-24-13 12-30-16 DUE TO VENDOR CHANGE IN 2005, <VALUES ARE LLD VALUES JANUARY THROUGH JUNE 2005 AND MDC VALUES AFTER JUNE 2005 C-15

FIGURE C-5 AIR PARTICULATES - GROSS BETA - STATIONS Z-01 AND Z-02 COLLECTED IN THE VICINITY OF ZNPS, 2000 - 2016 60.0 50.0

~ 40.0 0

Q. 30.0 I")

Cl

~ 20.0 10.0 Z-01 Onsite No. 1, Southside 0.0 --------+------------

01-05-00 05-30-03 10-22-06 03-16-10 08-08-13 12-31-16 70.0 60.0 50.0 I")

§ 0

40.0 Q.

9 30.0 w

Cl 20.0 10.0 Z-02 Onsite No. 2, Westside 0.0 ----+---------+-----+------I 01-05-00 05-30-03 10-22-06 03-16-10 08-08-13 12-31-16 C-16

I_~

FIGURE C-6 AIR PARTICULATES - GROSS BETA - STATIONS Z-03 COLLECTED IN THE VICINITY OF ZNPS, 2000 - 2016 Z-03 Onsite No. 3, Northside 90.0 80.0 70.0 M

60.0

.E 0 50.0 Cl.

.., 40.0 q w 30.0 Cl 20.0 10.0 0.0 01-05-00 05-30-03 10-22-06 03-16-10 08-08-13 12-31-16 AIR PARTICULATES - GROSS BETA - STATION Z-13 COLLECTED IN THE VICINITY OF ZNPS, 2013 - 2016 50.0 40.0 M

§ 30.0 0

Cl.

i:

20.0 Cl 10.0 Z-13 Offsite Control 0.0 +-----+-------------

04-10-13 03-16-14 02-19-15 01-25-16 12-30-16 C-17

APPENDIX D INTER-LABORATORY COMPARISON PROGRAM

TABLE D-1 ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1OF3)

Identification Reported Known Ratio (c)

Month/Year Number Matrix Nuclide Units Value (a)

Value (b)

TSE/Analytics Evaluation (d)

March 2016 E11476 Milk Sr-89 pCi/L 97 86.7 1.12 A

Sr-90 pCi/L 15 11.4 1.32 N(2)

E11477 Milk 1-131 pCi/L 85.9 82.2 1.05 A

Ce-141 pCi/L 106 98.4 1.08 A

Cr-51 pCi/L 255 243 1.05 A

Cs-134 pCi/L 134 130 1.03 A

Cs-137 pCi/L 174 161 1.08 A

Co-58 pCi/L 123 117 1.05 A

Mn-54 pCi/L 141 117 1.21 w

Fe-59 pCi/L 152 131 1.16 A

Zn-65 pCi/L 193 179 1.08 A

Co-60 pCi/L 259 244 1.06 A

E11479 AP Ce-141 pCi 69 81.1 0.85 A

Cr-51 pCi 242 201 1.20 w

Cs-134 pCi 98.1 107.0 0.92 A

Cs-137 pCi 136 133 1.02 A

Co-58 pCi 91.9 97 0.95 A

Mn-54 pCi 98.6 96.2 1.02 A

Fe-59 pCi 98.8 108 0.91 A

Zn-65 pCi 131 147 0.89 A

Co-60 pCi 209 201 1.04.

A E11478 Charcoal 1-131 pCi 85.3 88.3 0.97 A

E11480 Water Fe-55 pCi/L 1800 1666 1.08 A

June 2016 E11537 Milk Sr-89 pCi/L 94.4 94.4 1.00 A

Sr-90 pCi/L 13.4 15.4 0.87 A

E11538 Milk 1-131 pCi/L 96.8 94.5 1.02 A

Ce-141 pCi/L 129 139 0.93 A

Cr-51 pCi/L 240 276 0.87 A

Cs-134 pCi/L 157 174 0.90 A

Cs-137 pCi/L 117 120 0.98 A

Co-58 pCi/L 131 142 0.92 A

Mn-54 pCi/L 128 125 1.02 A

Fe-59 pCi/L 132 122 1.08 A

Zn-65 pCi/L 235 235 1.00 A

Co-60 pCi/L 169 173 0.98 A

June 2016 E11539 Charcoal 1-131 pCi 86.1 89.4 0.96 A

E11540 AP Ce-141 pCi 105 99.8 1.05 A

Cr-51 pCi 216 198.0 1.09 A

Cs-134 pCi 113 125 0.90 A

Cs-137 pCi 94.5 86.6 1.09 A

Co-58 pCi 101 102 0.99 A

Mn-54 pCi 88.8 90.2 0.98 A

Fe-59 pCi 82 87.5 0.94 A

Zn-65 pCi 174 169 1.03 A

Co-60 pCi 143 124 1.15 A

E11541 Water Fe-55 pCi/L 164 186 0.88 A

D-1

TABLE D-1 ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE2 OF 3)

Identification Reported Known Ratio (c)

Month/Year Number Matrix Nuclide Units Value(a)

Value (b)

  • TSE/Analytics Evaluation (d)

September 2016 E11609 Milk Sr-89 pCi/L 90 90.9 0.99 A

Sr-90 pCi/L 13.3 13.7 0.97 A

E11610 Milk 1-131 pCi/L 80.4 71.9 1.12 A

Ce-141 pCi/L 81.3 93 0.87 A

Cr-51 pCi/L 198 236 0.84 A

Cs-134 pCi/L 122 136 0.90 A

Cs-137 pCi/L 119 119 1.00 A

Co-58 pCi/L 92.2 97.4 0.95 A

Mn-54 pCi/L 156 152 1.03 A

Fe-59 pCi/L 97.5 90.6 1.08 A

Zn-65 pCi/L 189 179 1.06 A

Co-60 pCi/L 131 135 0.97 A

E11611 Charcoal 1-131 pCi 52.4 59.9 0.87 A

E11612 AP Ce-141 pCi 67.5 63.6 1.06 A

Cr-51 pCi 192 161.0 1.19 A

Cs-134 pCi 91.4 92.6 0.99 A

Cs-137 pCi 93.9 80.8 1.16 A

Co-58 pCi 66 66.4 0.99 A

Mn-54 pCi 104 104 1.00 A

Fe-59 pCi 60.5 61.8 0.98 A

Zn-65 pCi 140 122 1.15 A

Co-60 pCi 119 91.9 1.29 w

E11613 Water Fe-55 pCi/L 1990 1670 1.19 A

E11614 Soil Ce-141 pCi/g 0.153 0.175 0.87 A

Cr-51 pCi/g 0.482 0.441 1.09 A

Cs-134 pCi/g 0.270 0.254 1.06 A

Cs-137 pCi/g 0.313 0.299 1.05 A

Co-58 pCi/g 0.177 0.182 0.97 A

Mn-54 pCi/g 0.340 0.285 1.19 A

Fe-59 pCi/g 0.206 0.17 1.21 w

Zn-65 pCi/g 0.388 0.335 1.16 A

Co-60 pCi/g 0.284 0.252 1.13 A

December 2016 E11699 Milk Sr-89 pCi/L 95 74.2 1.28 w

Sr-90 pCi/L 14.7 10 1.47 N(3)

E11700 Milk 1-131 pCi/L 97.5 97.4 1.00 A

Ce-141 pCi/L 136 143 0.95 A

Cr-51 pCi/L 247 280 0.88 A

Cs-134 pCi/L 164 178 0.92 A

Cs-137 pCi/L 120 126 0.95 A

Co-58 pCi/L 139 146 0.95 A

Mn-54 pCi/L 126 129 0.98 A

Fe-59 pCi/L 114 125 0.91 A

Zn-65 pCi/L 237 244 0.97 A

Co-60 pCi/L 168 178 0.94 A

E11701 Charcoal 1-131 pCi 95.6 98 0.98 A

D-2

TABLE D-1 ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 3 OF 3)

Identification Reported Known Ratio (c)

MonthNear

  • Number Matrix Nuclide Units Value(a)

Value (b)

TB El Analytics December 2016 E11702 AP Ce-141 pCi 91.7 97.7 Cr-51 pCi 210 192.0 Cs-134 pCi 122 122 Cs-137 pCi 93.9 86.4 Co-58 pCi 92 100 Mn-54 pCi 93.7 88.5 Fe-59 pCi 84.9 84.5 Zn-65 pCi 176 167 Co-60 pCi 151 122 E11702 AP Sr-89 pCi 79.1 92 Sr-90 pCi 10 12.5 E11703 Water Fe-55 pCi/L 2180 1800 (a) Teledyne Brown Engineering reported result.

(b) The Analytics known value is equal to 100% of the parameter present in the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.

(c) Ratio of Teledyne Brown Engineering to Analytics results.

(d) Analytics evaluation based on TBE internal QC limits: A= Acceptable, reported result falls within ratio limits of 0.80-1.20.

W= Acceptable with warning, reported result falls within 0.70-0.80or1.20-1.30. N =Not Acceptable, reported result falls outside the ratio limits of< 0. 70 and> 1.30.

(2) NCR 16-26 was initiated (3) NCR 16-35 was initiated D-3 0.94 1.09 1.00 1.09 0.92 1.06 1.00 1.05 1.24 0.86 0.80 1.21 Evaluation (d)

A A

A A

A A

A A w A

A w

TABLE D-2 DOE's MIXEDANALYTE PERFORMANCE EVALUATION PROGRAM (MAPEP)

TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1OF1)

Identification Reported Known Acceptance Month/Year Number Media Nuclide Units Value (a)

Value (b)

Range March 2016 16-MaW34 Water Am-241 Sq/L 0.008 (1)

Ni-63 Sq/L 12.4 12.3 8.6-16.0 Pu-238 Sq/L 1.4900 1.2440 0.871-1.617 Pu-239/240 Sq/L 0.729 0.641 0.449-0.833 16-MaS34 Soil Ni-63 Sq/kg 1140 1250.0 875-1625 Sr-90 Sq/kg 8.15 (1) 16-RdF34 AP U-234/233 Sq/sample 0.1620 0.1650 0.116-0.215 U-238 Sq/sample 0.163 0.172 0.120-0.224 16-GrF34 AP Gr-A Sq/sample 0.608 1.20 0.36-2.04 Gr-S Sq/sample 0.8060 0.79 0.40-1.19 16-RdV34 Vegetation Cs-134 Sq/sample 10.10 10.62 7.43-13.81 Cs-137 Sq/sample 6.0 5.62 3.93-7.31 Co-57 Sq/sample 13.3000 11.8 8.3-15.3 Co-60 Sq/sample 0.013 (1)

Mn-54 Sq/sample 0.0150 (1)

Sr-90 Sq/sample 0.301 (1)

Zn-65 Sq/sample 10.500 9.6 6.7-12.5 September 2016 16-MaW35 Water Am-241 Sq/L 0.626 0.814

.570-1058 Ni-63 Sq/L 12.4 17.2 12.0-22.4 Pu-238 Sq/L 1.23 1.13 0.79-1.47 Pu-239/240 Sq/L 0.0318 0.013 (1) 16-MaS35 Soil Ni-63 Sq/kg 724 990 693-1287 Sr-90 Sq/kg 747 894 626-1162 16-RdF35 AP U-234/233 Sq/sample 0.160 0.15 0.105-0.195 U-238 Sq/sample 0.157 0.156 0.109-0.203 16-RdV35 Vegetation Cs-134 Sq/sample

-0.103 (1)

Cs-137 Sq/sample 5.64 5.54 3.88-7.20 Co-57 Sq/sample 7.38 6.81 4.77-8.85 Co-60 Sq/sample 4.81 4.86 3.40-6.32 Mn-54 Sq/sample 7.4 7.27 5.09-9.45 Sr-90 Sq/sample 0.774 0.80 0.56-1.04 Zn-65 Sq/sample 5.46 5.4 3.78-7.02 (1) False positive test.

(a) Teledyne Brown Engineering reported result.

(b) The MAPEP known value is equal to 100% of the parameter present in the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.

(c) DOEIMAPEP evaluation: A=acceptable, W=acceptable with warning, N=not acceptable.

(4)NCR 16-14 was initiated D-4 Evaluation (c)

A A

A A

A A

A A

A A

A A

A A

A N(4)

A w

A w

A A

A A

A A

A A

A A

A A

TABLE D-3 ERA ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1OF1)

Identification Reported Known Month/Year Number Media Nuclide Units Value (a)

Value (b)

May 2016 RAD-105 Water Sr-89 pCi/L 48.9 48.2 Sr-90 pCi/L 25.0 28.5 Ba-133 pCi/L 53.1 58.8 Cs-134 pCi/L 40.9 43.3 Cs-137 pCi/L 84.8 78.4 Co-60 pCi/L 108 102 Zn-65 pCi/L 226 214 Gr-A pCi/L 38.9 62.7 Gr-B pCi/L 41.9 39.2 1-131 pCi/L 24.1 26.6 U-Nat pCi/L 4.68 4.64 H-3 pCi/L 7720 7840 November 2016 RAD-107 Water Sr-89 pCi/L 43.0 43.3 Sr-90 pCi/L 30.0 33.6 Ba-133 pCi/L 47.8 54.9 Cs-134 pCi/L 72.9 81.8 Cs-137 pCi/L 189 210 Co-60 pCi/L 58.4 64.5 Zn-65 pCi/L 243 245 Gr-A pCi/L 37.2 68.4 Gr-B pCi/L 35.1 33.9 1-131 pCi/L 23.5 26.3 U-Nat pCi/L 49.2 51.2 H-3 pCi/L 918 9820 MRAD-25 AP Gr-A pCi/Filter 56.8 71.2 (a) Teledyne Brown Engineering reported result.

(b) The ERA known value is equal to 100% of the parameter present in the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.

(c) ERA evaluation: A=acceptable. Reported result falls within the Warning Limits. N=not acceptable. Reported result falls Acceptance Limits 37.8 - 55.6 20.7 - 33.1 48.7 - 64.9 34.6 - 47.6 70.6-88.9 91.8 - 114 193-251 32.9-77.8 26.0-467 22.1 - 31.3 3.39-5.68 6790- 8620 33.4-50.5 24.6-38.8 45.4-60.7 67.0-90.0 189-233 58.0-73.4 220-287 35.9-84.5 22.1-41.6 21.9-31.0 41.6-56.9 8540-10800 23.9-111 outside of the Control Limits. CE=check for Error. Reported result falls within the Control Limits and outside of the Warning Limit.

(5) NCR 16-34 was initiated D-5 Evaluation (c)

A A

A A

A A

A A

A A

A A

A A

A A

A A

A A

A A

A N(5)

A

TABLE D-4 ERA STATISTICAL

SUMMARY

PROFICIENCY TESTING PROGRAMa MRAD Study, ENVIRONMENTAL, INC., 2016 Concentration a Laboratory ERA Control Lab Code b Date Analysis Result Result Limits Acceptance ERAP-1101 3/14/2016 Am-241 37.3 45.9 28.3 - 62.1 Pass ERAP-1101 3/14/2016 Co-60 637 623 482 - 778 Pass ERAP-1101 3/14/2016 Cs-134 251 304 193 - 377 Pass ERAP-1101 3/14/2016 Cs-137 1,273 1,150 864 -1,510 Pass ERAP-1101 3/14/2016 Fe-55

< 162 126 39.1 - 246 Pass ERAP-1101 3/14/2016 Mn-54

<2.64

<50.0 0.00 - 50.0 Pass ERAP-1101 3/14/2016 Pu-238 68.0 70.5 48.3 - 92.7 Pass ERAP-1101 3/14/2016 Pu-239/240 54.1 54.8 39.70 - 71.60 Pass ERAP-1101 3/14/2016 Sr-90 139 150 73.3 - 225.0 Pass ERAP-1101 3/14/2016 U-233/234 59.3 64.8 40.2 - 97.7 Pass ERAP-1101 3/14/2016 U-238 55.5 64.2 41.5-88.8 Pass ERAP-1101 3/14/2016 Zn-65 428 356 255 -492 Pass ERAP-1101 3/14/2016 Gr. Alpha 98.0 70.1 23.5 - 109 Pass ERAP-1101 3/14/2016 Gr. Beta 78.6 54.4 34.4 - 79.3 Pass ERS0-1105 3/14/2016 Am-241 1,030 1,360 796 -1,770 Pass ERS0-1105 3/14/2016 Ac-228 1,540 '

1,240 795 -1,720 Pass ERS0-1105 3/14/2016 Bi-212 1,550 1,240 330 - 1,820 Pass ERS0-1105 3/14/2016 Bi-214 3,100 3,530 2, 130 - 5,080 Pass ERS0-1105 3/14/2016 Co-60 5,600 5,490 3,710 - 7,560 Pass ERS0-1105 3/14/2016 Cs-134 3,030 3,450 2,260 - 4, 140 Pass ERS0-1105 3/14/2016 Cs-137 4,440 4,310 3,300 - 5,550 Pass ERS0-1105 3/14/2016 K-40 10,300 10,600 7,740 - 14,200 Pass ERS0-1105 3/14/2016 Mn-54

< 50.8

< 1000 0.0 - 1,000 Pass ERS0-1105 3/14/2016 Pb-212 1,140 1,240 812 - 1,730 Pass ERS0-1105 3/14/2016 Pb-214 3,190 3,710 2, 170 - 5,530 Pass ERS0-1105 3/14/2016 Pu-238 680 658 396 - 908 Pass ERS0-1105 3/14/2016 Pu-239/240 460 496 324 - 0,685 Pass ERS0-1105 3/14/2016 Sr-90 7,740 8,560 3,260 - 13,500 Pass ERS0-1105 3/14/2016 Th-234 3,630 3,430 1,080 - 6,450 Pass ERS0-1105 3/14/2016 U-233/234 3,090 3,460 2,110 -4,430 Pass ERS0-1105 3/14/2016 U-238 3,280 3,430 2, 120 - 4,350 Pass ERS0-1105 3/14/2016 Zn-65 2,940 2,450 1,950 - 3,260 Pass ERW-1115 3/14/2016 Gr. Alpha 105.0 117.0 41.5-181.0 Pass ERW-1115 3/14/2016 Gr. Beta 76.2 75.5 43.2 - 112.0 Pass ERW-1117 3/14/2016 H-3 8,870 8,650 5,800 - 12,300 Pass ERVE-1108 3/14/2016 Am-241 1,930 2,120 1,300 - 2,820 Pass ERVE-1108 3/14/2016 Cm-244' 1,294 1,560 764 - 2,430 Pass ERVE-1108 3/14/2016 Co-60 1,164 1,100 759 -1,540 Pass ERVE-1108 3/14/2016 Cs-134 1,056 1,070 687 -1,390 Pass ERVE-1108 3/14/2016 Cs-137 930 838 608 -1,170 Pass ERVE-1108 3/14/2016 K-40 32,200 31,000 22,400 - 43,500 Pass ERVE-1108 3/14/2016 Mn-54

<24.5

<300 0.00 - 300 Pass ERVE-1108 3/14/2016 Zn-65 3,320 2,820 2,030 - 3,960 Pass D-6

TABLE D-4 ERA STATISTICAL

SUMMARY

PROFICIENCY TESTING PROGRAM 8

MRAD Study, ENVIRONMENTAL, INC., 2016 Concentration a Laboratory ERA Control Lab Code b Date Analysis Result Result Limits Acceptance ERVE-1108 3/14/2016 Pu-238 3,410 2,810 1,680 - 3,850 Pass ERVE-1108 3/14/2016 Pu-239/240 4,120 3,640 2,230 - 5,010 Pass ERVE-1108 3/14/2016 Sr-90 8,120 8,710 4,960 - 11,500 Pass ERVE-1108 3/14/2016 U-233/234 4,350 4,160 2,740 - 5,340 Pass ERVE-1108 3/14/2016 U-238 4,220 4,120 2, 750 - 5,230 Pass ERW-1111 3/14/2016 Am-241 113 121 81.5-162 Pass ERW-1111 3/14/2016 Co-60 1,120 1,050 912 - 1,230 Pass ERW-1111 3/14/2016 Cs-134 806 842 618 - 968 Pass ERW-1111 3/14/2016 Cs-137 1,190 1,100 934 -1,320 Pass ERW-1111 3/14/2016 Mn-54

< 5.89

< 100 0.00 - 100 Pass ERW-1111 3/14/2016 Pu-238 159 138 102 -172 Pass ERW-1111 3/14/2016 Pu-239/240 113 98.7 76.6 -124 Pass ERW-1111 3/14/2016 U-233/234 46.9 52.7 39.6 - 68.0 Pass ERW-1111 3/14/2016 U-238 50.4 52.3 39.9 - 64.2 Pass ERW-1111 3/14/2016 Zn-65 1,160 1,010 842 -1,270 Pass ERW-1111 3/14/2016 Fe-55 1,600 1,650 984 -2,240 Pass ERW-1111 3/14/2016 Sr-90 430 434 283 - 574 Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EML).

b Laboratory codes as follows: ERW (water), ERAP (air filter), ERSO (soil), ERVE (vegetation). Results are reported in units of pCi/L, except for air filters (pCi/Filter), vegetation and soil (pCi/kg).

0 Results are presented as the known \\(alues, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

D-7

TABLE D-5 DOE's Mixed Analyte Performance Evaluation Program (MAPEP)

ENVIRONMENTAL, INC., 2016 Concentration a Reference Known Control Lab Code b Date Analysis Laboratory result Activity Limits 0

Acceptance MAS0-1053 2/1/2016 Ni-63 1,206 +/- 20 1250 875 -1625 Pass MAS0-1053 2/1/2016 Sr-90 0.65 +/- 1.27 0.00 NA 0

Pass MAS0-1053 2/1/2016 Tc-99 0.1 +/- 5.5 0.0 NA c Pass MAS0-1053 2/1/2016 Cs-134 908 +/- 26 1030 721 - 1339 Pass MAS0-1053 2/1/2016 Cs-137 0.10 +/- 6.20 0.00 NA 0 Pass MAS0-1053 2/1/2016 Co-57 1058 +/- 26 992 694 -1290 Pass MAS0-1053 2/1/2016 Co-60 1229 +/- 28 1190 833 - 1547 Pass MAS0-1053 2/1/2016 Mn-54 1235 +/- 43 1160 812 - 1508 Pass MAS0-1053 2/1/2016 Zn-65 753 +/- 64 692 484 - 900 Pass MAS0-1053 2/1/2016 K-40 753 +/- 140 607 425 - 789 Pass MAS0-1053 2/1/2016 Am-241 79 +/-6 103 72 - 134 Pass MAS0-1053 2/1/2016 Pu-238 73.9 +/-9.2 63.6 44.5 - 82.7 Pass MAS0-1053 2/1/2016 Pu-239/240 0.76 +/- 1.34 0.21 NAd Pass MAS0-1053 2/1/2016 U-234/233 45.0 +/- 5.1 45.9 32.1 - 59.7 Pass MAS0-1053 2/1/2016 U-238 129 +/- 9 146 102 -190 Pass MAW-989 2/1/2016 Am-241 0.018 +/- 0.015 0.00 NA c Pass MAW-989 2/1/2016 H-3 0.2 +/- 2.8 0.0 NA c Pass MAW-989 2/1/2016 Ni-63 12.8 +/- 2.7 12.3 8.6 - 16.0 Pass MAW-989 2/1/2016 Sr-90 8.70+/-1.20 8.74 6.12 -11.36 Pass MAW-989 2/1/2016 Tc-99

-1.1 +/- 0.6 0.0 NA c Pass MAW-989 2/1/2016 Cs-134 15.5 +/- 0.3 16.1 11.3 +/- 20.9 Pass MAW-989 2/1/2016 Cs-137 23.7 +/- 0.5 21.2 14.8 - 27.6 Pass MAW-989e 2/1/2016 Co-57 1.38 +/- 0.12 0.00 NA c Fail MAW-989 2/1/2016 Co-60 12.5 +/- 0.3 11.8 8.3 - 15.3 Pass MAW-989 2/1/2016 Mn-54 12.2 +/- 0.4 11.1 7.8 - 14.4 Pass MAW-989 2/1/2016 Zn-65 15.7 +/- 0.7 13.6 9.5 - 17.7 Pass MAW-989 2/1/2016 K-40 288 +/-5 251 176 - 326 Pass MAW-989 2/1/2016 Fe-55 17.3 +/- 7.0 16.2 11.3-21.1 Pass MAW-989 2/1/2016 Ra-226 0.710 +/- 0.070 0.718 0.503 - 0.933 Pass MAW-989 2/1/2016 Pu-238 1.280 +/- 0.110 1.244 0.871 +/- 1.617 Pass MAW-989 2/1/2016 Pu-239/240 0.640 +/- 0.080 0.641 0.449 - 0.833 Pass MAW-989 2/1/2016 U-234/233 1.39 +/- 0.12 1.48 1.04 -1.92 Pass MAW-989 2/1/2016 U-238 1.43 +/- 0.12 1.53 1.07 -1.99 Pass MAW-893 2/1/2016 Gross Alpha 0.600 +/- 0.050 0.673 0.202 - 1.144 Pass MAW-893 2/1/2016 Gross Beta 2.10 +/- 0.06 2.15 1.08 - 3.23 Pass MAW-896 2/1/2016 1-129 3.67 +/- 0.20 3.85 2.70 - 5.01 Pass MMP-1056 2/1/2016 Gross Alpha 0.39 +/- 0.05 1.20 0.36 - 2.04 Pass MMP-1056 2/1/2016 Gross Beta 1.03 +/- 0.07 0.79 0.40 -1.19 Pass MMP-1057 2/1/2016 Sr-90 1.34 +/- 0.15 1.38 0.97+/-1.79 Pass MMP-1057 2/1/2016 Cs-134

-0.01 +/- 0.03 0.00 NA 0

Pass MMP-1057 2/1/2016 Cs-137 2.57 +/- 0.10 2.30 1.61 - 2.99 Pass D-8 (Page 1of3)

J

TABLE D-5 DOE's Mixed Analyte Performance Evaluation Program (MAPEP)

ENVIRONMENTAL, INC., 2016 Concentration a Reference Known Control Lab Code b Date Analysis Laboratory result Activity Limits c Acceptance MAAP-1057 2/1/2016 Co-57 3.01 +/- 0.06 2.94 2.06 - 3.82 Pass MAAP-1057 2/1/2016 Co-60 4.28 +/- 0.10 4.02 2.81 - 5.23 Pass MAAP-1057 2/1/2016 Mn-54 4.90 +/-0.13 4.53 3.17 - 5.89 Pass MAAP-1057 2/1/2016 Zn-65 4.09 +/- 0.18 3.57 2.50 - 4.64 Pass MAAP-1057 2/1/2016 Am-241 0.059 +/- 0.015 0.0805 0.0564 - 0.1047 Pass MAAP-1057 2/1/2016 Pu-238 0.066 +/- 0.020 0.0637 0.0446 - 0.0828 Pass MAAP-1057 2/1/2016 Pu-239/240 0.074 +/- 0.020 0.099 NA d Pass MAAP-1057 2/1/2016 U-234/233 0.151 +/- 0.026 0.165 0.116 - 0.215 Pass MAAP-1057 2/1/2016 U-238 0.160 +/- 0.026 0.172 0.120 - 0.224 Pass MAVE-1050 2/1/2016 Cs-134 9.83 +/- 0.19 10.62 7.43 - 13.81 Pass MAVE-1050 2/1/2016 Cs-137 6.06 +/- 0.19 5.62 3.93 - 7.31 Pass MAVE-1050 2/1/2016 Co-57 13.,8 +/- 0.2 11.8 8.3 -15.3 Pass MAVE-1050 2/1/2016 Co-60 0.022 +/- 0.040 0.00 NA c Pass MAVE-1050 2/1/2016 Mn-54 0.009 +/- 0.044 0.000 NA c Pass MAVE-1050 2/1/2016 Zn-65 10.67 +/- 0.39 9.60 6.70 -12.50 Pass MAS0-478d 8/1/2016 Ni-63 648+/-14 990 693 -1287 Fail MAS0-47809 8/1/2016 Ni-63 902 +/-46 990 693 - 1287 Pass MAS0-4780 8/1/2016 Sr-90 757+/-16 894 626 - 1162 Pass MAS0-4780 8/1/2016 Tc-99 559 +/- 12 556 389 - 723 Pass MAS0-4780 8/1/2016 Cs-134 0.93 +/- 2.92 0.00 NA c Pass MAS0-4780 8/1/2016 Cs-137 1061 +/- 12 1067 747 - 1387 Pass MAS0-4780 8/1/2016 Co-57 1178 +/- 8 1190 833 -1547 Pass MAS0-4780 8/1/2016 Co-60 841 +/- 9 851 596 -1106 Pass MAS0-4780 8/1/2016 Mn-54 0.69 +/- 2.53 0.00 NA c Pass MAS0-4780 8/1/2016 Zn-65 724 +/- 19 695 487 - 904 Pass MAS0-4780 8/1/2016 K-40 566 +/- 52 588 412 - 764 Pass MAS0-4780 8/1/2016 Am-241 0.494 +/- 0.698 0.000 NA c Pass MAS0-4780 8/1/2016 Pu-238 69.7 +/- 7.4 70.4 49.3 - 91.5 Pass MAS0-4780 8/1/2016 Pu-239/240 53.9 +/-6.3 53.8 37.7 - 69.9 Pass MAS0-4780h 8/1/2016 U-233/234 46.8 +/- 3.9 122 85 -159 Fail MAS0-4780h 8/1/2016 U-238 46.6 +/- 3.9 121 85 - 157 Fail MAW-4776 8/1/2016 1-129 4.40 +/- 0.20 4.54 3.18 - 5.90 Pass MAVE-4782 8/1/2016 Cs-134

-0.01 +/- 0.05 0.00 NA c Pass MAVE-4782 8/1/2016 Cs-137 6.18 +/- 0.20 5.54 3.88 - 7.20 Pass MAVE-4782 8/1/2016 Co-57 8.13 +/- 0.16 6.81 4.77 - 8.85 Pass MAVE-4782 8/1/2016 Co-60 5.30 +/- 0.15 4.86 3.40 - 6.32 Pass MAVE-4782 8/1/2016 Mn-54 8.08 +/- 0.24 7.27 5.09 - 9.45 Pass MAVE-4782 8/1/2016 Zn-65 6.24 +/- 0.36 5.40 3.78 - 7.02 Pass MAAP-4784 8/1/2016 Sr-90 1.18 +/- 0.10 1.03 0.72 -1.34 Pass MAAP-4784 8/1/2016 Cs-134 1.58 +/- 0.08 2.04 1.43 - 2.65 Pass D-9 (Page 2 of 3)

TABLE D-5 DOE's Mixed Analyte Performance Evaluation Program (MAPEP)

ENVIRONMENTAL, INC., 2016 Concentration a Reference Known Control Lab Code b Date Analysis Laboratory result Activity Limits c MMP-4784 8/1/2016 Cs-137 1.85 +/- 0.09 1.78 1.25 - 2.31 MMP-4784 8/1/2016 Co-57 2.39 +/- 0.52 2.48 1.74 - 3.22 MMP-4784 8/1/2016 Co-60 3.22 +/- 0.08 3.26 2.28 -4.24 MMP-4784 8/1/2016 Mn-54 2.82 +/-0.12 2.75 1.93 - 3.58 MMP-4784 8/1/2016 Zn-65

-0.015 +/- 0.062 0.00 NA c MMP-4784 8/1/2016 Am-241

-0.001 +/- 0.006 0.00 NA c MMP-4784 8/1/2016 Pu-238 0.075 +/- 0.022 0.069 0.049 - 0.090 MMP-4784 8/1/2016 Pu-239/240 0.048 +/- 0.015 0.054 0.038 - 0.070 MMP-4784 8/1/2016 U-234/233 0.151 +/- 0.036 0.150 0.105 - 0.195 MMP-4784 8/1/2016 U-238 0.147 +/-0.034 0.156 0.109 - 0.203 MAW-4778 8/1/2016 H-3 365+/-11 334 234 - 434 MAW-4778 8/1/2016 Fe-55 23.6+/-16.3 21.5 15.1 +/-28.0 MAW-4778 8/1/2016 Ni-63 17.0 +/- 2.8 17.2 12.0 +/- 22.4 MAW-4778 8/1/2016 Sr-90 0.17 +/- 0.28 0.00 NA c MAW-4778 8/1/2016 Tc-99 9.50 +/- 0.41 11.60 8.10 -15.10 MAW-4778 8/1/2016 Cs-134 22.6 +/- 0.4 23.9 16.7-31.1 MAW-4778 8/1/2016 Cs-137 0.018 +/- 0.117 0.00 NA c MAW-4778 8/1/2016 Co-57 27.6 +/- 0.2 27.3 19.1 +/- 35.5 MAW-4778 8/1/2016 Co-60 0.018 +/- 0.090 0.00 NAC MAW-4778 8/1/2016 Mn-54 16.2 +/- 0.4 14.8 I 10.4-19.2 MAW-4778 8/1/2016 Zn-65 19.3 +/- 0.7 17.4 12.2 - 22.6 MAW-4778 8/1/2016 K-40 286 +/-6 252 176 - 328 MAW-4778 8/1/2016 Ra-226 1.48 +/- 0.09 1.33 0.93 - 1.73 MAW-4778 8/1/2016 Pu-238 1.09 +/- 0.13 1.13 0.79 -1.47 MAW-4778 8/1/2016 Pu-239/240 0.003 +/- 0.011 0.016 NA d MAW-4778 8/1/2016 U-234/233 1.80 +/- 0.13 1.86 1.30 - 2.42 MAW-4778 8/1/2016 U-238 1.77 +/- 0.13 1.92 1.34 - 2.50 MAW-4778 8/1/2016 Am-241 0.678 +/- 0.086 0.814 0.570 +/- 1.058 a Results are reported in units of Bq/kg (soil), Bq/L (water) or Sq/total sample (filters, vegetation).

b Laboratory codes as follows: MAW (water), MAAP (air filter), MASO (soil), MAVE (vegetation).

0 MAPEP results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP. A known value of "zero" indicates an analysis was included in the testing series as a "false positive". MAPEP does not provide control limits.

d Provided in the series for "sensitivity evaluation". MAPEP does not provide control limits.

Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass 0 The laboratory properly identified the Sn-75 interfering peak in the vicinity of Co-57 and stated so in the comment field. MAPEP requires results to be reported as an activity with an uncertainty. Since the calculated uncertainty was less than the activity MAPEP interpreted the submitted result as a "false positive" resulting in a failure.

1 Original analysis for Ni-63 failed.

9 Reanalysis with a smaller aliquot resulted in acceptable results. An investigation is in process to identify better techniques for analyzing samples with complex matrices.

h MAPEP states that samples contain two fractions of Uranium; one that is soluble in concentrated HN03 and HCI acid and one that is "fundamentally insoluble in these acids". They also state that HF treatment can not assure complete dissolution.

Results are consistent with measuring the soluble form.

D-10 (Page 3 of 3)

TABLE D-6 lnterlaboratory Comparison Crosscheck Program, Environmental Resource Associates (ERA) a RAD Study, ENVIRONMENTAL, INC., 2016 Concentration (pCi/L)

Lab Code Date Analysis Laboratory ERA Control Result Result Limits Acceptance ERW-1392 4/4/2016 Sr-89 43.5 +/-4.3 48.2 37.8 - 55.6 Pass ERW-1392 4/4/2016 Sr-90 27.5+/-1.9 28.5 20.7 - 33.1 Pass ERW-1394 b 4/4/2016 Ba-133 65.2 +/- 3.8 58.8 48.7 - 64.9 Fail ERW-1394 c 4/4/2016 Ba-133 57.8 +/-5.3 58.8 48.7 - 64.9.

Pass ERW-1394 4/4/2016 Cs-134 43.7 +/-3.0 43.3 34.6 - 47.6 Pass ERW-1394 4/4/2016 Cs-137 86.1 +/- 5.3 78.4 70.6 - 88.9 Pass ERW-1394 4/4/2016 Co-60 108 +/- 44 102 91.8-114 Pass ERW-1394 4/4/2016 Zn-65 240+/-13 214 193 - 251 Pass ERW-1397 4/4/2016 Gr. Alpha 52.0 +/-2.2 62.7 32.9 - 77.8 Pass ERW-1397 4/4/2016 Gr. Beta 33.9+/-1.2 39.2 26.0 - 46.7 Pass ERW-1400 4/4/2016 1-131 24.7 +/- 0.6 26.6 22.1-31.3 Pass ERW-1402 4/4/2016 Ra-226 15.6 +/- 0.5 15.2 11.3-17.4 Pass ERW-1402 4/4/2016 Ra-228 5.28 +/- 0.76 5.19 3.12 -6.93 Pass ERW-1403 4/4/2016 Uranium 4.02 +/- 0.42 4.64 3.39 - 5.68 Pass ERW-1405 4/4/2016 H-3 8,150 +/-270 7,840 6,790 - 8,620 Pass SPW-2845 7/7/2015 Ba-133 60.3 +/- 5.7 64.7 53.9 - 71.2 Pass SPW-2845 7/7/2015 Cs-134 48.8 +/- 9.3 50.1 40.3 - 55.1 Pass SPW-2845 7/7/2015 Cs-137 101 +/- 8 89.8 80.8 - 101 Pass SPW-2845 7/7/2015 Co-60 65.1 +/- 5.8 59.9 53.9 - 68.4 Pass SPW-2845 7/7/2015 Zn-65 288 +/-29 265 238 - 310 Pass ERW-3485 7/11/2016 Sr-89 43.3 +/- 6.5 53.3 42.3 - 60.9 Pass ERW-3485 7/11/2016 Sr-90 39.0 +/- 2.8 39.2 28.8 - 45.1 Pass ERW-3487 7/11/2016 Ba-133 83.3 +/-4.9 82.9 69.7-91.2 Pass ERW-3487 7/11/2016 Cs-134 62.5 +/-4.4 65.3 53.1 - 71.8 Pass ERW-3487 7/11/2016 Cs-137 98.1 +/- 5.6 95.2 85.7 -107 Pass ERW-3487 7/11/2016 Co-60 122 +/- 5 117 105 - 131 Pass ERW-3487 7/11/2016 Zn-65 124 +/- 9 113 102 -134 Pass ERW-3490 7/11/2016 Gr. Alpha 46.6 +/-2.2 48.1 25.0 - 60.5 Pass ERW-3490 7/11/2016 Gr. Beta 26.8+/-1.1 28.6 18.2 - 36.4 Pass ERW-3492 7/11/2016 1-131 23.7 +/- 1.0 24.9 20.7 - 29.5 Pass ERW-3493 7/11/2016 Ra-226 12.9 +/- 0.4 12.3 9.2 - 14.2 Pass ERW-3493 7/11/2016 Ra-228 5.8 +/- 0.8 5.8 3.5 - 7.6 Pass ERW-3493 7/11/2016 Uranium 32.8 +/- 0.8 25.2 28.4 - 39.3 Pass ERW-3495 7/11/2016 H-3 12,400 +/- 334 12,400 10,800 - 13,600 Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by Environmental Resources Associates (ERA).

b No reason determined for failure of Ba-133 result.

0 The result of reanalysis (Compare to original result, footnoted "b" above).

D-11

APPENDIX E EFFLUENT DATA

TABLE OF CONTENTS INTRODUCTION................................................................................................................. 1

SUMMARY

........................................................................................................................... 2 1.0. EFFLUENTS..................................................................................................... 3 1.1. Gaseous Effluents to the Atmosphere................................................... 3 1.2. Liquids Released to Lake Michigan....................................................... 3 2.0. SOLID RADIOACTIVE WASTE........................................................................ 3 3.0. DOSE TO MAN................................................................................................. 3 3.1. Gaseous Effluent Pathways................................................................... 3 3.1.1. Gaseous Releases.................................................................. 4 3.1.1.1. Gamma Dose Rates.................................................. 4 3.1.1.2. Beta Air and Skin Dose Rate.....................................4 3.1.2. Radioactive Iodine................................................................... 4 3.1.3. Dose to Thyroid........................................................................ 5 3.2. Liquid Effluent Pathways........................................................................ 5 3.3. Direct Radi~tion...................................................................................... 5 3.4. Assessment of Dose to Member of Public............................................. 6 4.0. SITE METEOROLOGY..................................................................................... 6

Table of Contents (cont.)

APPENDIX E-1 DATA TABLES AND FIGURES..........................................................................................................................

E-1.1 Station Releases Table 3.1-1 Maximum Dose Resulting from Airborne Releases E-1.2 Table 3.2-1 Maximum Dose Resulting from Liquid Effluents E-1.6 Table 3.3-1 Maximum Dose Resulting from Direct Radiation E-1.10 Table 3.4-1 10CFR20 Compliance Assessment E-1.11 Table 3.5-1 Doses Resulting from Airborne Releases E-1.15 ii

INTRODUCTION Units 1 and 2 of the Zion Station, located in Zion, Illinois adjacent to Lake Michigan, were 1100 MWe (3520 MWt) Westinghouse pressurized water reactors. The plant permanently ceased operation in February of 1998 and has been permanently defueled. The station is in an advanced state of decommissioning.

The station was designed to keep releases to the environment at levels below those specified in the regulations. Historical data has been established that Zion, as a fully operational facility, did not contribute appreciable doses to the surrounding public. Sampling results for 2016 showed minimal releases above background for a variety of monitored pathways, e.g. water, vegetation, air samples and TLD.

Liquid effluents from Zion Station are released to Lake Michigan in controlled batches after radioassay of each batch and continuously through a monitored pathway. There are no routine noble gas releases. Due to decay, iodine is no longer present. The only noble gas that remained prior to January 2015 was Kr-85 captured in the spent fuel assemblies stored in the fuel pool in the fuel building. During January 2015, the last fuel assembly was removed from the fuel building and Kr-85 is no longer present in the fuel handling building. The results of effluent analyses are summarized on a monthly basis and reported to the Nuclear Regulatory Commission as required per Quality Assurance Project Plan which replaced the Technical Specifications after spent fuel was transferred to the ISFSI. Airborne concentrations of noble ga~es and particulate radioactivity in offsite areas are calculated using efflu~nt and historical meteorological data.

Currently Zion Station is undergoing decommissioning. During the decommissioning process, containerized waste is temporarily maintained at designated locations onsite. The designated locations are located in a manner to minimize the direct radiation exposure to the public at or near the site boundary.

Environmental monitoring was conducted by sampling at indicator and control (background) locations in the vicinity of the Zion Station to measure changes in radiation or radioactivity levels that may be attributable to the station. If significant changes attributable to Zion Station are measured, these changes are correlated with effluent releases or direct radiation from containerized waste.

ISFSI operations were conducted in 2016 which attributed direct radiation dose in the form of gamma and neutron radiation to members of the public. The results of the calculated dose from direct radiation from the ISFSI have been calculated and included in this report. In addition to the dose contributed to members of the public, a special case exists for members of the public working onsite in the switchyard area. Switchyard worker dose results are also included in this report.

1

SUMMARY

Gaseous, liquid and solid waste effluents for the period contributed to only a small fraction of the Station Technical Specification limits. Calculations of environmental concentrations based on effluent and historical meteorological data for the period indicate that consumption by the public of radionuclides attributable to the Zion Station does not exceed regulatory limits. Radiation exposure from direct radiation from the ISFSI and containerized waste at the site boundary represented the critical pathway for the period with a maximum individual total body dose estimated to be 1.49E+01 mrem for the year, where a factor to analyze exposure based on habits of the real individual of 3.38-01 was applied at the maximally exposed receptor. The assessment of radiation doses is performed in accordance with the Zion Station Offsite Dose Calculation Manual (ODCM). The results of analysis confirm that the station is operating in compliance with 10 CFR 50 Appendix I, 10 CFR 20, 10 CFR 72 and 40 CFR 190.

2

1.0 EFFLUENTS 1.1 Gaseous Effluents to the Atmosphere Measured concentrations and isotopic composition of noble gases and particulate radioactivity released to the atmosphere were monitored during the year. A total of O.OOE+OO microcuries

(µCi) of fission and activation gases was released with a maximum average release rate of O.OOE+OO µCi/sec during any one quarter period.

A total of 4.51 E-04 curies of beta-gamma emitters was released as airborne particulate matter with a maximum average quarterly release rate of 1.43E-05 µCi/sec. Alpha-emitting radionuclides were less than measurable detection limits. O.OOE+OO curies of tritium were released with a maximum average quarterly release rate of O.OOE+OO µCi/sec.

1.2 Liquids Released to Lake Michigan A total of 8.69e+06 liters of liquid waste containing 1.17E-02 curies of fission and activation products, 1.65E-01 curies of tritium, and 1.31 E-05 Ci of Alpha was discharged from the station via an approved pathway after dilution with a total of 1.41 E+09 liters of water. These wastes were released at a maximum quarterly average concentration of 3.59E-08 µCi/ml. Monthly release estimates and principal radionuciides in liquid effluents are reported in the Zion Nuclear Power Station Radioactive Effluent Report for 2016.

2.0 SOLID RADIOACTIVE WASTE There were 191 solid radioactive waste shipments in 2016. For more detail, refer to the Zion Station 2016 Annual Radioactive Effluent Release Report.

3.0 DOSE TO MAN 3.1 Gaseous Effluent Pathways Table 3.1-1 summarizes the doses resulting from releases of airborne radioactivity via the different exposure pathways.

3

3.1.1 Gaseous Releases 3.1.1.1 Gamma Dose Rates Offsite Gamma air and whole (total) body dose rates are shown in Table 3.1-1 and were calculated based on measured release rates, isotopic composition of the gases, and meteorological data for the period. Based on measured effluents and historical meteorological data, the maximum total body dose to an individual would be 2.96E-02 mrem (adult) for the year (Table 3.5-1), with an occupancy or shielding factor of 0.7 included. The maximum gamma air dose was O.OOE+OO mrad based on *measured effluents and average historical meteorological data (Table 3.5-1).

3.1.1.2 Beta Air and Skin Dose Rates The range of beta particles in air is relatively small (on the order of a few meters or less);

consequently, plumes of gaseous effluents may be considered "infinite" for purpose of calculating the dose from beta radiation incident on the skin.

However, the actual dose to sensitive skin tissues is difficult to calculate due to the effect of the beta particle energies, thick'ness of inert skin and clothing covering sensitive tissues. For purposes of this report the skin is taken to have a thickness of 7.0 mg/cm2 and an occupancy factor of 1.0 is used. The skin dose from beta and gamma radiation for the year O.OOE+OO mrem based on measured effluents and historical meteorological data (Table 3'.$-1).

The maximum offsite bet.a air dose for the year was O.OOE+OO mrad based on measured effluents and historical meteorological data (Table 3.5-1).

3.1.2 Radioactive Iodine The human thyroid exhibits a significant capacity to concentrate ingested or inhaled iodine. The radioiodine, 1-131, released during routine operation of the station, may 4

be made available to man resulting in a dose to the thyroid.

The principal pathway of interest for this radionuclide is ingestion of radioiodine in milk. As Zion Station is not operational and 1-131 has decayed away, the maximum offsite concentration is estimated to be zero, as expected.

3.1.3 Dose to Thyroid The hypothetical thyroid dose to a maximum exposed individual living near the station via ingestion of milk was calculated. As Zion Station is not operational and 1-131 has decayed away, the maximum offsite concentration is estimated to be zero, as expected.

3.2 Liquid Effluent Pathways The three principal pathways through the aquatic environment for potential doses to man from liquid waste are ingestion of potable water, eating aquatic foods, and exposure while on the shoreline.

Not all of these pathways are significant or applicable at a given time but a reasonable approximation of the dose can be made by adjusting the dose formula for season of the year or type and degree of use of the aqu'atic environment. NRC developed equations* were used to calculate the doses to the whole body, lower GI tracts, thyroid, bone, skin; specific parameters for use in the equations are given in the Zion Station Offsite Dose Calculation Manual. The maximum whole body dose (total body) for the year was 8.73E-03 mrem and no organ dose exceeded 3.1 OE-02 mrem (Table 3.2-1).

3.3 Direct Radiation During the period January to December 2016, Zion Station during decommissioning has stored containerized radioactive waste combined with direct radiation from the ISFSI (including gamma plus neutron) that contributed a total of 1.49E+01 mrem to the whole body of a maximally exposed individual at site boundary taking into account the occupancy factor of 3.38E-01 calculated in Zion Station ES&H Technical Support Document (TSO)13-009 "Member of the Public Dose from All Onsite Sources." The maximally exposed member of the public working in the switchyard onsite was calculated to receive 9.98E+01 mrem to the whole body at the south switchyard boµndary. This value takes into account the occupancy factor of 2.38E~01 as described in ES&H TSO 13-009 referenced above. During Quarters 1-3 of 2016 the historical Harshaw TLD100 5

dosimeters were used to estimate dose. The Harshaw TLD100 gamma readings are known to over-respond in the presence of neutrons. During Quarter 4 of 2016, a study on TLD over-response was completed and the Harshaw TLD1 OOs were replaced with Panasonic TLD814 Environmental TLDs which do not over-respond in the presence of neutrons. No correction has been made for the over-response in the above dose values as the values above demonstrate regulatory compliance.

3.4 Assessment of Dose to Member of Public During the period January to December, 2016, Zion Station did not exceed the below limits as shown in Table 3.1-1 and Table 3.2-1 (based on yearly average meteorological data), and Table 3.3 (based on TLD results):

The RETS limits on dose or dose commitment to an individual due to radioactive materials in liquid effluents from each reactor unit (3 mrem to the whole body or 10 mrem to any organ during any calendar year).

The RETS limits on air dose in noble gases released in gaseous effluents to a member of the public from each reactor unit (10 mrad for gamma radiation or 20 mrad for beta radiation during arw calendar year).

The RETS limits on dose to a member of the public due to iodine-131, iodine-133, tritium, and radionuclides in particulate form 'with half-lives greater than eight days in gaseous effluents released from each reactor unit (15 mrem to any organ during any calendar year).

The 10 CFR 20 limit on Total Effective Dose Equivalent to individual members of the public (100 mrem).

The 10 CFR 72.104 limit on Total Effective Dose Equivalent to individual members of the public from combined effluents and radioactive material including ISFSl(25 mrem).

4.0 SITE METEOROLOGY A summary of the site meteorological measurements taken during the period of operation of the meteorological tower is given in Appendix 11. After fuel was removed from the fuel building, the meteorological tower was no longer required and the tower was removed. A new historical average of the meteorological data 6

was created to reflect current parameters and the data are presented as cumulative joint frequency which represents a time period from January 1 2009 to December 31 2014.

  • Nuclear Regulatory Commission, Regulatory Guide 1.109 (Rev. 1) distributions of the wind direction for the 250' level and wind speed class by atmospheric stability class determined from the temperature difference between the 250' and 35' levels. Data recovery for these measurements was 99.6% during 2016 (Table 3.5-1).

7

Table 3.1-1 Maximum Dose Resulting from Airborne Releases Zion Station 2016 GASEOUS EFFLUENTS -

SUMMATION OF ALL RELEASES Unit 1 Vent Stack -

GROUND RELEASES REPORT FOR 2016 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Gases

1. Total Release Ci
2. Avg. Release Rate

µCi/sec Iodine-131

1. Total Release
2. Avg. Release Rate Ci

µCi/sec Particulates Half Life >= 8 days

<LLD

<LLD

<LLD

<LLD

1. Total Release Ci 6.39E-06
2. Avg. Release Rate

µCi/sec 8.22E-07 Tritium

1. Total Release
2. Avg. Release Rate Ci

µCi/sec Gross Alpha Radioactivity

1. Total Release Ci

<LLD

<LLD

<LLD

2. Avg. Release Rate

µCi/sec

<LLD

<LLD

<LLD

<LLD

<LLD 1.82E-05 2.31E-06

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD 7.03E-06 8.84E-07

<LLD

<LLD

<LLD

<LLD GASEOUS EFFLUENTS -

GROUND RELEASES -

CONTINUOUS MODE

<LLD

<LLD

<LLD

<LLD 9.28E-07 1.17E-07

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD 3.25E-05 1.03E-06

<LLD

<LLD

<LLD

<LLD REPORT FOR 2016 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Gases Iodines Particulates Half Life >= 8 days

<LLD

<LLD C0-60 Ci 2.06E-06 CS-137 NI-63 Ci Ci 4.21E-06 3.51E-09

<LLD

<LLD 7.86E-06

1. 03E-05 O.OOE+OO

<LLD

<LLD 3.30E-06 3.73E-06 O.OOE+OO

<LLD

<LLD O.OOE+OO O.OOE+OO O.OOE+OO

<LLD

<LLD l.32E-05 1.83E-05 3.51E-09 Totals for Period...

Ci 6.27E-06 1.82E-05 7.03E-06 O.OOE+OO 3.15E-05 Tritium

<LLD

<LLD

<LLD

<LLD

<LLD Gross Alpha Radioactivity

<LLD

<LLD

<LLD

<LLD

<LLD E-1.1

Table 3.1-l(continued)

Maximum Dose Resulting from Airborne Releases Zion Station 2016 REPORT FOR 2016 GASEOUS EFFLUENTS -

SUMMATION OF ALL RELEASES Unit 2 Vent Stack -

GROUND RELEASES Units QTR 1 QTR 2 QTR 3 QTR 4 Fission and Activation Gases

1. Total Release Ci

<LLD

<LLD

<LLD

<LLD

2. Avg. Release Rate

µCi/sec

<LLD

<LLD

<LLD

<LLD Iodine-131

1. Total Release Ci

<LLD

<LLD

<LLD

<LLD

2. Avg. Release Rate

µCi/sec

<LLD

<LLD

<LLD

<LLD Particulates Half Life >= 8 days YEAR

<LLD

<LLD

<LLD

<LLD

1. Total Release Ci 4.03E-04
2. Avg. Release Rate uCi/sec 5.18E-05 l.14E-05
1. 44E-06 5.48E-06

<LLD 6.90E-07

<LLD 4.20E-04 l.33E-05 Tritium

1. Total Release Ci

<LLD

<LLD

<LLD

<LLD

<LLD

2. Avg. Release Rate

µCi/sec

<LLD

<LLD

<LLD

<LLD

<LLD Gross Alpha Radioact,ivity

1. Total Release Ci

<LLD

<LLD

<LLD

<LLD

<LLD

2. Avg. Release Rate

µCi/sec

<LLD

<LLD

<LLD

<LLD

<LLD GASEOUS EFFLUENTS -

GROUND RELEASES -

CONTINUOUS MODE REPORT* FOR 2016 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation

<LLD

<LLD

<LLD

<LLD

<LLD Gases Iodines

<LLD

<LLD

<LLD

<LLD

<LLD Particulates Half Life >= 8 days C0-60 Ci 2.37E-04 6.26E-06 l.67E-06

<LLD 2.45E-04 CS-137 Ci l.66E-04 5.09E-06

3. 81E-06

<LLD l.75E-04 Totals for Period...

Ci 4.03E-04 l.14E-05 5.48E-06

<LLD 4.20E-04 Tritium

<LLD

<LLD

<LLD

<LLD

<LLD Gross Alpha Radioactivity

<LLD

<LLD

<LLD

<LLD

<LLD E-1.2

Table 3.1-l(continued)

Maximum Dose Resulting from Airborne Releases Zion Station 2016 40 CFR 190 URANIUM FUEL CYCLE DOSE REPORT GAS ANNUAL DOSE

SUMMARY

Year.................. : 2016 From Unit............. : 1 To Unit............... : 2 Coefficient Type...... : Historical Gas Receptor.......... : 5 Composite Crit. Receptor -

IP Distance (meters)..... : 0.00 Compass Point......... : NA

--- MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)===================================

Dose Age Dose Limit Adrnin Adm in

% T.Spec T.Spec %

Period Group Organ (mrem)

Period Limit of Limit Limit of Limit Quarter 1 INFANT LIVER 9.03E-02 Quarter 5.63E+OO l.61E+OO 7.SOE+OO l.20E+OO Quarter 2 INFANT LIVER 7.84E-03 Quarter 5.63E+OO 1. 39E-01 7.SOE+OO l.OSE-01 Quarter 3 INFANT LIVER 3.75E-03 Quarter 5.63E+OO 6.67E-02 7.SOE+OO 5.00E-02 Quarter 4 INFANT LIVER 3.78E-04 Quarter 5.63E+OO 6. 72E-03 7.SOE+OO 5.04E-03 Annual INFANT LIVER l.02E-01 Annual l.13E+Ol 9.09E-01

1. SOE+Ol 6.82E-01

--- MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))===================================

Dose Age Dose Limit Adrnin Adm in

% T.Spec T.Spec %

Period Group Organ (mrem)

Period Limit of Limit Limit of Limit Quarter 1 ADULT TBODY 2.65E-02 Quarter 5.25E+OO 5.04E-01 7.SOE+OO 3.53E-01 Quarter 2 ADULT TBODY 2.0SE-03 Quarter 5.25E+OO 3.91E-02 7.SOE+OO 2.74E-02 Quarter 3 ADULT TBODY 9.16E-04 Quarter 5.25E+OO l.75E-02 7.SOE+OO l.22E-02 Quarter 4 ADULT TBODY 7.89E-05 Quarter 5.25E+OO 1. SOE-03 7.SOE+OO l.OSE-03 Annual ADULT TBODY 2.95E-02 Annual

1. OSE+Ol 2.81E-01
1. SOE+Ol l.97E-01 E-1.3

Table 3.1-l(continued)

Maximum Dose Resulting from Airborne Releases Zion Station 2016 GASEOUS RELEASE AND DOSE

SUMMARY

REPORT (Composite Critical Receptor - Limited Analysis)

Release ID........... : 1 All Gas Releases Period Start Date.... : 01/01/2016 00:00 Period End Date...... : 01/01/2017 00:00 Period Duration (min): 5.270E+05 Coefficient Type..... : Historical From Unit............ :

0 To Unit.............. :

2 Receptor............. : 5 Composite Crit. Receptor -

IP Distance (meters).... : 0.0 Compass Point........ : 0.0

MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)================================

Dose Age Dose Limit Admin Admin T-. Spec T. Spec %

Period Group Organ (mrem)

Period Limit of Limit Limit of Limit Strt->End INFANT LIVER l.02E-01 31-day 2.25E-01 4.SSE+Ol Quarter 5.63E+OO l.82E+OO Annual l.13E+Ol 9.09E-01 Critical Pathway........ : 3 Grs/Goat/Milk (GMILK)

Major Contributors...... : 0.0

% or greater to total Nuclide Percentage C0-60 NI-63 CS-137 l.12E+Ol l.SlE-05 8.88E+Ol 3.00E-01 3.41E+Ol 7.SOE+OO l.36E+OO l.SOE+Ol 6.82E-01

MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))================================

Dose Age Dose Limit Admin Admin

% T.Spec T.Spec %

Period Group Organ (mrem)

Period Limit of Limit Limit of Limit Strt->End ADULT TBODY 2.95E-02 31-day l.SOE-01 l.97E+Ol Quarter 5.25E+OO 5.62E-01 Annual

1. OSE+Ol 2.BlE-01 Critical Pathway........ : 0 Ground Plane Deposition (GPO)

Major Contributors...... : 0.0

% or greater to total Nuclide Percentage C0-60 NI-63 CS-137 3.97E+Ol 2.67E-05 6.03E+Ol E-1.4 2.00E-01 l.48E+Ol 7.SOE+OO 3.93E-01 l.SOE+Ol l.97E-01

Table 3.2-1 Maximum Dose Resulting from Liquid Effluents Zion Station 2016 LIQUID EFFLUENTS -

SUMMATION OF ALL RELEASES (Unit 1 & Unit 2 combined)

REPORT FOR 2016 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Gases C-14 Ci C0-60 Ci CS-137 Ci FE-55 NI-59 NI-63 PU-241 SR-90 Ci Ci Ci Ci Ci Totals for Period...

Ci Tritium H-3 Ci Totals for Period...

Ci Dissolved and Entrained Gases

1. Total Release Ci Gross Alpha Radioactivity ALPHA Ci Totals for Period...

Ci Volume of liquid waste liters Permit dilution vol ltr 3.64E-04

8. llE-04
1. 82E-04 l.12E-04
l. lOE-04 9.16E-03 9.0BE-06 4.47E-06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.61E-05
1. 99E-04 2.26E-04 O.OOE+OO O.OOE+OO 2.53E-04 O.OOE+OO l.56E-05 2.44E-06 l.86E-05 l.40E-04 O.OOE+OO O.OOE+OO 2.36E-05 O.OOE+OO
1. 4 6E-06 3.92E-04 l.03E-03 5.48E-04 l.12E-04
l. lOE-04 9.43E-03 9.0BE-06 2.15E-05 l.07E-02 O.OOE+OO 7.19E-04 l.86E-04 l.17E-02 6.52E-02 O.OOE+OO 9.31E-02 6.63E-03 l.65E-01 6.52E-02 O.OOE+OO 9.31E-02 6.63E-03 l.65E-01

<LLD

<LLD

<LLD

<LLD

<LLD 4.86E-06 O.OOE+OO 8.27E-06 O.OOE+OO l.31E-05 4.86E-06 O.OOE+OO 8.27E-06 O.OOE+OO l.31E-05 7.38E+06 4.07E+05 6.55E+05 2.45E+05 8.69E+06 l.26E+09 O.OOE+OO 1.28E+08 2.23E+07 l.41E+09 LIQUID EFFLUENTS -

CONTINUOUS MODE (Unit 1 & Unit 2 combined)

REPORT FOR 2016 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Products <LLD Tritium Dissolved and Entrained Gases Gross Alpha Radioactivity

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD E-1.5

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD*

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

Table 3.2-1 (continued)

Maximum Dose Resulting from Liquid Effluents Zion Station 2016 LIQUID EFFLUENTS -

BATCH MODE (Unit 1 & Unit 2 combined)

REPORT FOR 2016 Units Fission and Activation Products C-14 Ci C0-60 Ci CS-137 FE-55 NI-59 NI-63 PU-241 SR-90 Ci Ci Ci Ci Ci Ci Totals for Period...

Ci Tritium H-3 Ci Totals for Period...

Ci QTR 1 3.64E-04 8.llE-04 1.82E-04 1.12E-04

l. lOE-04 9.16E-03 9.0BE-06 4.47E-06 QTR 2 N/A N/A N/A N/A N/A N/A N/A N/A 1.07E-02 N/A 6.52E-02 N/A 6.52E-02 N/A Dissolved and Entrained Gases

<LLD N/A Gross Alpha Radioactivity ALPHA Ci

4. 86E-06 N/A Totals for Period...

Ci 4.86E-06 N/A SUPPLEMENTAL INFORMATION LIQUID EFFLUENTS - BATCH MODE REPORT FOR 2016 Units QTR 1 QTR 2 Number of releases 14 0

Total release time minutes 3.32E+04 O.OOE+OO Maximum release time minutes 3.32E+03 O.OOE+OO Average release time minutes 2.37E+03 O.OOE+OO Minimum release time minutes 2.40E+02 O.OOE+OO Permit dilution vol ltr

1. 26E+09 O.OOE+OO Permit dilution flow gpm
1. OOE+04 O.OOE+OO Permit max total diluted concentration (no H-3) µCi/ml 3.23E-08 O.OOE+OO Period dilution vol ltr 4.96E+09 4.96E+09 Period dilution flow gpm
1. OOE+04
1. OOE+04 E-1.6 QTR 3 QTR 4 YEAR
2. 61E-05 1.99E-04 2.26E-04

<LLD

<LLD 2.53E-04

<LLD 1.56E-05 2.44E-06 l.86E-05

1. 40E-04

<LLD

<LLD 2.36E-05

<LLD 1.46E-06 3.92E-04 1.03E-03 5.48E-04 1.12E-04 1.lOE-04 9.43E-03 9.0SE-06 2.15E-05 7.19E-04 1.86E-04 1.17E-02 9.31E-02 6.63E-03 1.65E-01 9.31E-02 6.63E-03 1.65E-01

<LLD

<LLD

<LLD 8.27E-06

<LLD l.31E-05 8.27E-06

<LLD 1.31E-05 QTR 3 QTR 4 YEAR 12 5

31 8.76E+03 5.83E+02 4.26E+04 6.67E+03 l.59E+02 6.67E+03 7.30E+02 1.17E+02

1. 37E+03 1.12E+02 5.90E+Ol 5.90E+Ol 1.28E+08 2.23E+07
1. 41E+09 3.85E+03 l.01E+04 8.74E+03 3.59E-08 2.41E-08 3.59E-08 5.01E+09 5.01E+09 2.00E+lO
1. OOE+04 1.00E+04
1. OOE+04

Table 3.2-1 (continued)

Maximum Dose Resulting from Liquid Effluents Zion Station 2016 40 CFR 190 URANIUM FUEL CYCLE DOSE REPORT LIQUID ANNUAL DOSE

SUMMARY

Year.................. : 2016 From Unit............. :

1 To Unit............... :

2 Liquid Receptor....... : 0 Liquid Receptor

--- MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)===================================

Dose Age Dose Limit Admin Admin

% T.Spec T.Spec %

Period Group Organ (mrem)

Period Limit of Limit Limit of Limit Quarter 1 CHILD BONE 2.16E-02 Quarter 2.50E+OO 8.66E-01 2.50E+OO 8.66E-01 Quarter 2 ADULT BONE O.OOE+OO Quarter 2.50E+OO O.OOE+OO 2.50E+OO O.OOE+OO Quarter 3 CHILD BONE 6.04E-03 Quarter 2.50E+OO 2.42E-01 2.50E+OO 2.42E-01 Quarter 4 TEEN LIVER 3.36E-03 Quarter 2.50E+OO 1. 34E-01 2.50E+OO 1.34E-01 Annual CHILD BONE 3.lOE-02 Annual 5.00E+OO 6.19E-01 5.00E+OO 6.19E-01

--- MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))===================================

Dose Age Dose Limit Admin Admin

% T.Spec T.Spec %

Period Group Organ (mrem)

Period Limit of Limit Limit of Limit Quarter 1 ADULT TBODY 3.19E-03 Quarter 1. 50E+OO 2.13E-01

1. 50E+OO 2.13E-01 Quarter 2 ADULT TBODY O.OOE+OO Quarter 1. 50E+OO O.OOE+OO
1. 50E+OO O.OOE+OO Quarter 3 ADULT TBODY 3.42E-03 Quarter 1.50E+OO 2.28E-01
1. 50E+OO 2.28E-01 Quarter 4 ADULT TBODY 2.12E-03 Quarter 1.50E+OO 1. 41E-01
1. 50E+OO 1. 41E-01 Annual ADULT TBODY 8.73E-03 Annual 3.00E+OO 2.91E-01 3.00E+OO 2.91E-01 E-1.7

Table 3. 2-1 * (continued)

Maximum Dose Resulting from Liquid Effluents Zion Station 2016 40 CFR 190 URANIUM FUEL CYCLE DOSE REPORT LIQUID RELEASE AND DOSE

SUMMARY

REPORT (PERIOD BASIS) -----------

Release ID............ : 1 All Liquid Release Types Period Start Date..... : 01/01/2016 00:00 Period End Date....... : 01/01/2017 00:00 Period Duration (mins): 5.270E+05 Receptor.............. : 0 Liquid Receptor

MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)================================

Dose Age Dose Limit Admin Adm in Period Group Organ (mrem)

Period Limit of Limit Strt->End CHILD BONE 3.lOE-02 31-day 5.00E+OO 6.19E-01 Quarter 2.50E+OO 1. 24E+OO Annual 5.00E+OO 6.19E-01 Critical Pathway........ : 1 Fresh Water Fish - Sport (FFSP)

Major Contributors...... : 0.0

% or greater to total Nuclide Percentage H-3 FE-55 C0-60 NI-63 SR-90 CS-137 O.OOE+OO l.47E-02 O.OOE+OO 5.78E+Ol 1.98E+OO 4.00E+Ol T.Spec T.Spec %

Limit of Limit 5.00E+OO 6.19E-01 2.50E+OO 1. 24E+OO 5.00E+OO 6.19E-01

MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))================================

Dose Age Dose Limit Admin Admin

% T.Spec T.Spec %

Period Group Organ (mrem)

Period Limit of Limit Limit of Limit Strt->End ADULT TBODY 8.73E-03 31-day 3.00E+OO 2. 91E-01 Quarter 1.50E+OO 5.82E-01 Annual 3.00E+OO 2.91E-01 Critical Pathway........ : 1 Fresh Water Fish - Sport (FFSP)

Major Contributors...... : 0.0

% or greater to total Nuclide Percentage H-3 2.22E-02 FE-55 6.03E-03 C0-60 2.99E-01 NI-63 5.02E+OO SR-90 l.41E-01 CS-137 9.45E+Ol E-1.8 3.00E+OO 2.91E-01 1.50E+OO 5.82E-01 3.00E+OO 2.91E-01

Table 3.3-1 Maximum Dose Resulting from Direct Radiation Zion Station 2016 Maximally exposed sector: J (25mrem/year limit)

Unit Qtr 1 mrem Qtr 2 mrem Qtr 3 mrem Qtr 4 mrem 2016 mr em)

Unit 1 Unit 2 ISFSl-amma ISF&l-neutron Sum:

1.93E+OO 1.20E+OO 6.33E-01 7.33E-01 4.SOE+O 0 1.93E+OO 1.20E+OO 6.33E-01 7.33E-01 4.SOE+O 0 1.93E+OO 1.20E+OO 6.33E-01 7.33E-01 4.SOE+O 0 6.00E-01 3.00E-01 3.00E-01 2.00E-01 1.40E+O 0 6.40E+OO 3.90E+OO 2.20E+OO 2.40E+OO 1.49E+O 1 Maximally exposed switchyard: Switchyard South (lOOmrem/year limit)

Switch ard Qtr 1 mrem Qtr 2 mrem Qtr 3 mrem Qtr 4 mrem 2016 mr em)

Gamma 2.44E+01 2.97E+01 2.47E+01 1.16E+01 9.04E+01 Neutron 2.40E+OO 2.40E+OO 3.40E+OO 1.20E+OO 9.40E+OO Sum 2.68E+01 3.21 E+01 2.81 E+01 1.28E+01 9.98E+01 E-1.9 I

I

Table 3.4-1 ZION STATION 2016 Unit 1 10 CFR 20 Compliance Assessment

1.

1 O CFR 20.1301 (a) (1) Compliance Total Effective Dose Equivalent 4.50E+OO mrem/year 10 CFR 20.1301 (a) (1) limit 100 mrem/year

% of the limit 4.50E+OO %

2.

Compliance Summary 1 O CFR 20 1st Qtr.

2nd Qtr.

4th Qtr

% of Limit TEDE 1.93E+OO 1.20E+OO 6.33E-01 7.33E-01 4.50E+OO%

E-1.10

Table 3.4-1 (continued)

ZION STATION 2016 Unit2 10 CFR 20 Compliance Assessment

1.

1 O CFR 20.1301 (a) (1) Compliance Total Effective Dose Equivalent 4.50E+OO mrem/year 10 CFR 20.1301 (a) (1) limit 100 mrem/year

% of the limit 4.50E+OO %

2.

Compliance Summary 10 CFR 20 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr

% of Limit TEDE 1.93E+OO 1.20E+OO 6.33E-01 7.33E-01 4.50E+OO%

E-1.11

Table 3.4-1 (continued)

ZION STATION 2016 Switch yard 10 CFR 20 Compliance Assessment

1.

10 CFR 20.1301 (a) (1) Compliance Total Effective Dose Equivalent 9.98E+01 mrem/year 10 CFR 20.1301 (a) (1) limit 100 mrem/year

% of the limit 9.98E+01 %

2.

Compliance Summary 1 O CFR 20 2nd Qtr.

3rd Qtr.

4th Qtr

% of Limit TEDE 2.68E+01 3.21E+01 2.81E+01 1.28E+01 9.98E+01%

  • Note: Qtr 1,2,3 Harshaw TLD100 represents 30% gamma over-response. Qtr 4 TLD changed to Panasonic TLD 814 which does not over-respond when in presence of neutrons E-1.12

Table 3.4-1 (continued)

ZION STATION 2016 ISFSI 10 CFR 72.104 Compliance Assessment

1.

10 CFR 72.104 (a) (2) Compliance Total Effective Dose Equivalent 5.90E+OO mrem/year 10 CFR 72.104 (a) limit 25 mrem/year

% of the limit 2.36E+01 %

2.

Compliance Summary 10 CFR 20 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr

% of Limit TEDE 2.53E+OO 1.50E+OO 9.33E-01 9.33E-01 2.36E+01%

E-1.13

Table 3.5-1 Doses Resulting from Airborne Releases The following are the maximum annual calculated cumulative offsite doses resulting from Zion Station airborne releases.

Unit 1:

Dose Maximum Value Sector Affected gamma air <1>

O.OOE+OO mrad beta air <2>

O.OOE+OO mrad whole body <3>

1.48E-02 mrem East skin <4>

O.OOE+OO mrem East organ <5> (infant liver)

5. 1 OE-02 mrem East Unit 2:

Dose Maximum Value Sector Affected gamma air <1>

O.OOE+OO mrad beta air <2>

O.OOE+OO mrad whole body <3>

1.48E-02 mrem East skin <4>

O.OOE+OO mrem East organ <5> (infant liver) 3.40E-01 mrem East All values based on historical values of atmospheric dispersion coefficients and XOQDOQ values reflecting the. time period from Jan. 1, 2009 to Dec. 31 2014.

Meteorological Tower was removed March 2015.

Data recovery: 98. 71 %

(1) Gamma Air Dose - GASPAR II, NUREG-0597 (2) Beta Air Dose - GASPAR II, NUREG-0597 (3) Whole Body Dose - GASPAR II, NUREG-0597 (4) Skin Dose - GASPAR II, NUREG-0597 (5) Inhalation and Food Pathways Dose - GASPAR II, NUREG-0597 E-1.14

APPENDIX F METEOROLOGICAL DATA

1. Introduction The purpose of the meteorological program conducted at Zion Station site was to provide information sufficient to assess the local weather conditions and was used to determine the degree of atmospheric dispersion of airborne radioactive effluent from the station.

During the first quarter of 2015, all fuel had been removed to the ISFSI location and continuous meteorological monitoring was no longer required. The previous 6 years of data from Jan. 1, 2009 to Dec. 31, 2014 was queried to generate the historic average wind rose and atmospheric dispersion parameters for future airborne effluents from Zion Station.

The method of dose calculation that will be used going forward is ground level release and relevant information that is applicable to this method of effluent dose calculation has been included in this report.

The meteorological tower that was used in calculation of these historical averages was 250 ft. in elevation and was instrumented at two levels. Wind speed and direction measured at 35 ft. and 250 ft. Ambient temperature was measured at 35 ft. Differential temperature, referenced to 35 ft. was measured at 250 ft. Dew point temperature was measured approximately ten feet from the tower at an elevation of 5 ft. Precipitation was measured by a rain gauge located on the roof of the meteorological shelter building.

Joint frequency stability wind rose tables of wind direction, wind speed, and stability were routinely tabulated from hourly measurements during the six year period of this historical average. The six year historical average data tables are included in this report.

2. Summary Zion Station meteorological monitoring program produced 51,918 total hours valid for the instruments used in generating the historical average out of a possible 52596 total hours in the 6 year monitoring period from Jan. 1, 2009 to Dec. 31, 2014. (365.25 days X 6 years X 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s/day). 678 total hours of data were lost representing a 98.71% data recovery rate.

The stability wind rose tables included in this report have been generated using the 35 ft. wind data with the 250-35 ft. differential temperature data.

3. Data Acquisition Information regarding Data Acquisition, Data Analysis and instruments used can be found in the meteorological monitoring sections of prior Zion Stations Annual Radioactive Environmental Monitoring Reports from 2009 to 2014.

F-1

Table 1 Wind Direction Classes Wind Direction Class Compass Direction the Wind is Coming From N

348.75°

<WD s; 11.25° NNE 11.25°

<WDs; 11.25° NE 33.75°

<WD s; 33.75° ENE 56.25°

<WD s; 56.25° E

78.75°

<WD s; 78.75° ESE 101.25°

<WD s; 101.25° SE 123.75°

<WD s; 123.75° SSE 146.. 25°

<WD s; 146.25° s

168.75°

<WD s; 168.75° SSW 191.25°

<WD s; 191.25° SW 213.75°

<WD s; 213.75° WSW 236.25°

<WD s; 236.25° w

258.75°

<WD s; 258.75° WNW 281.25°

<WD s; 281.25° NW 303.75°

<WD s; 303.75° NNW 326.25°

<WD s; 348.75° Table 2 Wind Soeed Classes Wind Speed Class Wind Speeds are in miles per hour (mph) 1 0.0

<WS s; 0.7 2

0.7

< ws s; 3.5 3

3.5

< ws s; 7.5 4

7.5

< ws s; 12.5 5

12.5

< ws s; 18.5 6

18.5

< ws s; 24.5 7

24.5

<WS F-2

Class A - Extremely Unstable B - Moderately Unstable c-Slightly Unstable D-Neutral E - Slightly Stable F - Moderately Stable G - Extremely Stable (1) From ANSI/ANS 2.5 Table 3 Atmosoheric Stabilitv Classes Differential Temperature Interval (in °C/100m}(1l ilT s -1.9

-1.9 < ilT s -1.7

-1.7 < ilT s -1.5

-1.5 < ilT s -0.5

-0.5 < ilT s 1.5 1.5 < ilT s 4.0 4.0 < ilT Differential Temperature Interval (in °F over the 250-35 ft. interval}(2l ilT S -2.3

-2.3 < ilT S -2.1

-2.1 < ilT s -1.8

-1.8 < ilT S -0.6

-0.6 < ilT s 1.7 1.7 < ilT s 4.7 4.7 < ilT (2) ANSI/ANS 2.5 intervals scaled for instrument heights on the Zion meteorological tower.

F-3

4. The following two programs were used to calculate doses resulting from radioactive releases:
a. XOQDOQ: Computer Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations (NUREG/CR-2919)

The program is based on the theory that material released to the atmosphere will be normally distributed (Gaussian) about the plume centerline. A straight-line trajectory is assumed between the point of release and all receptors.

The program implements the assumptions outlined in Section C of NRC Regulatory Guide 1.111. In evaluating routine releases from nuclear power plants, it primarily is designed to calculate annual relative effluent concentrations, XIQ values and annual average relative deposition, D/Q values.

The historical average output from the XOQDOQ program from 2009-2014 was used to develop the input to the RETDAS program.

b. RETDAS: Radiological Effluent Tracking and Dose Assessment Software.

RETDAS is a program written for the evaluation of radiological impacts due to the release of radioactive material to the environment during normal operation of reactors. The RETDAS code implements the radiological impact models of NRC Regulatory Guide 1.109 Rev. 1, for atmospheric releases. The program is used to estimate the maximum individual doses at the maximally exposed location in the vicinity of the plant.

F-4

5. Detailed information regarding the meteorological maintenance and calibration information of the meteorological tower and instruments used during the historical average evaluation time period can be found in prior Zion Station Annual Radioactive Environmental Operating Reports from 2009 to 2014.
6. Stability Wind Rose Data The historical stability wind roses are given in Tables 4 through 8. For the year, winds measured at 35ft. most frequently came from the West (10.86%) and fell into the 3.6 to 7.5 mph wind speed class (34.94%). Calms (wind speeds at or below 1mph were measured at 0.16% of the time and speeds greater than 24.5 mph were measured 0.09% of the time.

Stability based on the 250-35 ft. differential temperature most frequently fell into the neutral classification (39.58%)

F-5

  • Period of Record:

Stability Class:

Elevation:

Wind

<1 Direction N

0 NNE 0

NE 0

ENE 0

E 0

ESE 0

SE 0

SSE 0

s 0

SSW 0

SW 0

WSW 0

w 0

WNW 0

NW 0

NNW 0

Total:

0 Table 4 Percent of time at each Wind Speed and Direction Jan. 1, 2009 to Dec. 31, 2014 A-Extremely Unstable Ground Level Release Wind Speed (mph) at lOm Level 1-3.5 3.6 - 7.5 7.6 - 12.5 12.6 -18.5 18.6 - 24.5 0

0.031 0.156 0.254 0.04 0

0.176 0.98 0.287 0.006 0.002 0.391 0.559 0.075 0.004 0.002 0.368 0.22 0.019 0.002 0.004 0.412 0.133 0.023 0

0.002 0.379 0.141 0

0 0

0.272 0.219 0.01 0

0 0.05 0.249 0.035 0

0 0.01 0.046 0.019 0

0.002 0.015 0.068 0.144 0.01 0.002 0.041 0.319 0.331 0.015 0

0.133 0.516 0.366 0.021 0

0.12 0.577 0.401 0.01 0

0.089 0.492 0.187 0.002 0.006 0.068 0.404 0.112 0

0 0.039 0.058 0.037 0

0.019 2.591 5.137 2.3 0.11 F*6

>24.5 Total:

0.002 0.48 0

1.45 0

1.03 0

0.61 0

0.57 0

0.52 0

0.5 0

0.33 0

0.08 0

0.24 0.006 0.71 0.004 1.04 0

1.11 0

0.77 0

0.59 0

0.13 0.012 10.17

Period of Record:

Stability Class:

Elevation:

Wind

<1 Direction N

0 NNE 0

NE 0

ENE 0

E 0

ESE 0

SE 0

SSE 0

s 0

SSW 0

SW 0

WSW 0

w 0

WNW 0

NW 0

NNW 0

Total:

0 Percent of time at each Wind Speed and Direction Jan. 1, 2009 to Dec. 31, 2014 B - Moderately Unstable Ground Level Release Wind Speed (mph) at 10m Level 1-3.5 3.6 - 7.5 7.6 -12.5 12.6 -18.5 18.6-24.5 0

0.039 0.102 0.119 0.015 0

0.112 0.196 0.058 0.004 0.012 0.108 0.052 0.014 0.004 0.012 0.068 0.029 0.014 0

0.004 0.077 0.025 0.002 0

0.008 0.066 0.045 0

0 0

0.097 0.041 0

0 0

0.06 0.164 0.025 0

0 0.01 0.052 0.008 0.002 0

0.013 0.058 0.098 0.008 0.002 0.033 0.149 0.158 0.013 0

0.062 0.193 0.089 0.012 0.002 0.068 0.211 0.129 0.004 0

0.06 0.179 0.081 0.004 0.004 0.049 0.191 0.052 0

0.002 0.021 0.054 0.027 0.002 0.044 0.938 1.739 0.872 0.067 F-7

>24.5 Total:

0 0.28 0.002 0.37 0

0.19 0

0.12 0

0.11 0

0.12 0

0.14 0

0.25 0

0.07 0.002 0.18 0.002 0.36 0.002 0.36 0

0.41 0

0.32 0

0.29 0

0.11 0.008 3.67

Period of Record:

Stability Class:

Elevation:

Wind

<1 Direction N

0 NNE 0

NE 0

ENE 0

E 0

ESE 0

SE 0

SSE 0

s 0

SSW 0

SW 0

WSW 0

w 0

WNW 0

NW 0

NNW 0

Total:

0 Percent of time at each Wind Speed and Direction Jan. 1, 2009 to Dec. 31, 2014 C - Slightly Unstable Ground Level Release Wind Speed (mph) at 10m Level 1-3.5 3.6 - 7.5 7.6 - 12.5 12.6-18.5 18.6-24.5 0.004 0.086 0.243 0.177 0.013 0.01 0.183 0.31 0.079 0.004 0.023 0.15 0.102 0.031 0.01 0.023 0.1 0.044 0.021 0.012 0.01 0.146 0.025 0.018 0

0.019 0.115 0.037 0.014 0

0.006 0.181 0.054 0.016 0

0.006 0.106 0.351 0.11 0.01 0.004 0.066 0.101 0.021' 0

0.002 0.041 0.119 0.154 0.017 0

0.094 0.244 0.189 0.023 0.004 0.11 0.252 0.139 0.01 0.008 0.133 0.277 0~165 0.008 0.008 0.127 0.308 0.079 0

0.01 0.096 0.206 0.096 0

0.01 0.033 0.133 0.045 0.004 0.145 1.768 2.806 1.352 0.11 F-8

>24.5 Total:

0.008 0.53 0

0.59 0.006 0.32 0.002 0.2 0

0.2 0

0.18 0

0.26 0

0.58 0

0.19 0.004 0.34 0.006 0.56 0.002 0.52 0

0.59 0

0.52 0

0.41 0

0.22 0.027 6.21

Period of Record:

Stability Class:

Eleva~ion:

Wind

<1 Direction N

0 NNE 0

NE 0

ENE 0.001 E

0 ESE 0

SE 0

SSE 0

s 0

SSW 0

SW 0

WSW 0.001 w

0 WNW 0

NW 0

NNW 0

Total:

0.006 Percent of time at each Wind Speed and Direction Jan. 1, 2009 to Dec. 31, 2014 D - Neutral Ground Level Release Wind Speed (mph) at 10m Level 1-3.5 3.6-7.5 7.6 -12.5 12.6-18.5 18.6 - 24.5 0.102 0.597 1.392 1.05 0.21 0.142 0.758 1.123 0.769 0.042 0.161 0.528 0.57 0.405 0.046 0.137 0;348 0.346 0.347 0.092 0.121 0.392 0.303 0.353 0.094 0.148 0.489 0.289 0.163 0.035 0.127 0.567 0.378 0.149 0.008 0.075 0.523 1.258 0.944 0.168 0.106 0.686 0.805 0.314 0.015 0.128 0.641 0.994 0.774 0.087 0.152 0.612 1.443 1.003 0.108 0.138 0.849 1.327 0.659 0.042 0.146 1.1 1.766 0.961 0.029 0.169 1.139 1.402 0.52 0.012 0.164 1

1.404 0.489 0.021 0.098 0.655 1.21 0.387 0.039 2.117 10.886 16.01 9.286 1.048 F-9

>24.5 Total:

0.06 3.41 0.031 2.87 0.025 1.74 0.008 1.28 0.013 1.28 0.002 1.13 0

1.23 0.054 3.02 0

1.93 0.008 2.63 0.015 3.33 0.002 3.02 0.002 4

0 3.24 0

3.08 0.006 2.39 0.225 39.58

Period of Record:

Stability Class:

Elevation:

Wind

<1 Direction N

0.005 NNE 0.004 NE 0.004 ENE 0.003 E

0.003 ESE 0.002 SE 0.003 SSE 0.004 s

0.005 SSW 0.005 SW 0.006 WSW 0.004 w

0.005 WNW 0.005 NW 0.005 NNW 0.004 Total:

0.065 Percent of time at each Wind Speed and Direction Jan. 1, 2009 to Dec. 31, 2014 E - Slightly Stable Ground Level Release Wind Speed (mph) at lOm Level 1-3.5 3.6 - 7.5 7.6 -12.5 12.6 -18.5 18.6 - 24.5 0.302 0.672 0.53 0.173 0.021 0.245 0.564 0.447 0.058 0.013 0.204 0.314 0.167 0.075 0.002 0.154 0.212 0.092 0.071 0.01 0.148 0.212 0.082 0.11 0.054 0.129 0.233 0.091 0.052 0.017 0.163 0.456 0.273 0.079 0.004 0.192 0.452 0.84 0.291 0.029 0.292 1.375 0.839 0.166 0.004 0.441 1.19 0.661 0.154 0.015 0.324 0.855 0.607 0.183 0.013 0.277 1.008 0.503 0.069 0.002 0.353 1.349 0.649 0.117 0.006 0.38 1.136 0.599 0.05 0.002 0.319 1.069 0.48 0.073 0

0.252 0.593 0.203 0.058 0

4.178 11.692 7.063 1.779 0.193 F-10

>24.5 Total:

0.012 1.72 0

1.33 0

0.77 0

0.54 0.008 0.62 0

0.52

  • o 0.98 0.019' 1.83 0

2.68 0

2.47 0

1.99 0

1.86 0.002 2.48 0

2.17 0

1.95 0

1.11 0.04 25.01

Period of Record:

Stability Class:

Elevation:

Wind

<1 Direction N

0.002 NNE 0.001 NE 0.001 ENE 0.001 E

0.001 ESE 0.001 SE 0.001 SSE 0.001 s

0.003 SSW 0.004 SW 0.005 WSW 0.005 w

0.005 WNW 0.003 NW 0.004 NNW 0.003 Total:

0.042 Percent oftime at each Wind Speed and Direction Jan. 1, 2009 to Dec. 31, 2014 F - Moderately Stable Ground Level Release Wind Speed (mph) at 10m Level 1-3.5 3.6 - 7.5 7.6 - 12.5 12.6 -18.5 18.6-24.5 0.151 0.162 0.043 0

0 0.094 0.106 0.019 0

0 0.083 0.086 0.025 0

0 0.076 0.064 0.024 0.014 0.002 0.079 0.077 0.027 0.01 0

0.077 0.111 0.045 0.016 0

0.072 0.156 0.07 0.006 0

0.068 0.154 0.351 0.118 0.013 0.24 0.714 0.368 0.08 0.002 0.472 0.51 0.031 0.004 0

0.454 0.334 0.023 0.002 0

0.495 0.368 0.015 0

0 0.416 0.637 0.015 0

0 0.307 0.458 0.008 0

0 0.333 0.466 0.012 0

0 0.202 0.165 0.002 0.002 0

3.618 4.571 1.075 0.251 0.017 F-11

>24.5 Total:

0 0.36 0

0.22 0

0.2 0

0.18 0

0.19 0

0.25 0

0.3 0

0.7 0

1.41 0

1.02 0

0.82 0

0.88 0

1.07 0

0.78 0

0.82 0

0.37 0

9.57

Period of Record:

Stability Class:

Elevation:

Wind

<l Direction N

0.001 NNE 0.001 NE 0.001 ENE 0.001 E

0.001 ESE 0.001 SE 0.001 SSE 0.001 s

0.002 SSW 0.005 SW 0.005 WSW 0.006 w

0.008 WNW 0.007 NW 0.003 NNW 0.003 Total:

0.048 Percent of time at each Wind Speed and Direction Jan. 1, 2009 to Dec. 31, 2014 G - Extremely Stable Ground Level Release Wind Speed (mph) at lOm Level 1-3.5 3.6-7.5 7.6 - 12.5 12.6 -18.5 18.6 - 24.5 0.058 0.025 0

0 0

0.034 0.028 0

0 0

0.03 0.01 0.008 0.002 0

0.029 0.018 0.008 0.012 0

0.033 0.029 0.02 0.008 0

0.039 0.058 0.021 0.004 0

0.034 0.066 0.029 0.002 0

0.052 0.095 0.167 0.054 0

0.116' 0.424 0.316 0.057 0

0.256 0.11 0.006 0

0 0.258 0.189 0

0 0

0.481 0.316 0

0 0

0.586 0.609 0

0 0

0.353 0.401 0

0 0

0.104 0.108 0

0 0

0.071 0.016 0

0 0

2.534 2.498 0.574 0.139 0

F-12

>24.5 Total:

0 0.08 0

0.06 0

0.05 0

0.07 0

0.09 0

0.12 0

0.13 0

0.37 0

0.91 0

0.38 0

0.45 0

0.8 0

1.2 0

0.76 0

0.22 0

0.09 0

5.79

Table 5 Percent Wind Direction by Stability Class Wind Stability Class Direction A

B c

D E

F G

Total N

0.48 0.28 0.53 3.4 1.72 0.36 0.08 6.86 NNE 1.45 0.37 0.59 2.9 1.33 0.22 0.06 6.89 NE 1.03 0.19 0.32 1.7 0.77 0.2 0.05 4.3 ENE 0.61 0.12 0.2 1.3 0.54 0.18 0.07 3

E 0.57 0.11 0.2 1.3 0.62 0.19 0.09 3.06 ESE 0.52 0.12 0.18 1.1 0.52 0.25 0.12 2.84 SE 0.5 0.14 0.26 1.2 0.98 03 0.13 3.54 SSE 0.33 0.25 0.58 3.0 1.83 0.7 0.37 7.08 s

0.08 0.07 0.19 1.9 2.68 1.41 0.91 7.27 SSW 0.24 0.18 0.34 2.6 2.47 1.02 0.38 7.26 SW 0.71 0.36 0.56 3.3 1.99 0.82 0.:45 8.22 WSW 1.04 0.36 0.52 3.02 1.86 0.88 0.8 8.48 w

1.11 0.41 0.59 4

2.48 1.07 1.2 10.86 WNW 0.77 0.32 0.52 3.24 2.17 0.78 0.76 8.56 NW 0.59 0.29 0.41 3.08 1.95 0.82 0.22 7.36 NNW 0.13 0.11 0.22 2.39 1.11 0.37 0.09 4.42 TOTAL 10.17 3.67 6.21 39.58 25.01 9.57 5.79 100 F-13

Table 6 Percent Wind Direction by Wind Speed Wind Speed in mph Wind

<1 1-3.5 3.6 - 7.5 7.6 - 12.5 12.6-18.6-

>24.5 Total:

Direction 18.5 24.5 N

0.008 0.617 1.612 2.466 1.773 0.299 0.082 6.86 NNE 0.006 0.525 1.927 3.075 1.251 0.069 0.033 6.89 NE 0.006 0.515 1.587 1.483 0.602 0.066 0.031 4.3 ENE 0.006 0.433 1.178 0.763 0.498 0.118 0.01 3

E 0.005 0.399 1.345 0.615 0.524 0.148 0.021 3.06 ESE 0.004 0.422 1.451 0.669 0.249 0.052 0.002 2.84 SE 0.005 0.402 1.795 1.064 0.262 0.012 0

3.54 SSE 0.006 0.393 1.44 3.38 1.577 0.22 0.073 7.08 s

0.01 0.758 3.285 2.527 0.665 0.023 0

7.27 SSW 0.014 1.301 2.52 1.937 1.328 0.137 0.014 7.26 SW 0.016 1.192 2.158 2.785 1.866 0.172 0.029 8.22 WSW 0.016 1.395 2.846 2.806 1.322 0.087 0.01 8.48 w

0.018 1.511 4.016 3.495 1.773 0.057 0.004 10.86 WNW 0.015 1.217 3.41 2.988 0.917 0.02 0

8.56 NW 0.012 0.94 2.856 2.697 0.822 0.021 0

7.36 NNW 0.01 0.635 1.522 1.66 0.55.6 0.045 0.006 4.42 Total 0.161 12.655 34.944 34.404 15'.979 1.545 0.312 100 F-14


~

Table 7 Percent Speed by Stability Class Speed Stability Class (mph)

A B

c D

E F

G Total

<l 0

0 0

0.006 0.065 0.042 0.048 0.161 1-3.5 0.227 0.177 0.524 4.22 6.601 4.625 3.303 19.677 3.6 - 7.5 2.591 0.938 1.768 10.886 11.692 4.571 2.498 34.944 7.6 -12.5 5.137 1.739 2.806 16.01 7.063 1.075 0.574 34.404 12.6 -

2.3 0.872 1.352 9.286 1.779 0.251 0.139 15.979 18.5 18.6-0.11 0.067 0.11 1.048 0.193 0.017 0

1.545 24.5

>24.5 0.012 0.008 0.027 0.225 0.04 0

0 0.312 Total:

10.17 3.67 6.21 39.58 25.01 9.57 5.79 100 F-15

APPENDIX G ANNUAL RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM REPORT (ARGPPR}