ML16308A232

From kanterella
Jump to navigation Jump to search

Steam Generator Tube Inspection Report - Refueling Outage 19
ML16308A232
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 10/26/2016
From: Weber T
Arizona Public Service Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
102-07366-TNW/MDD
Download: ML16308A232 (87)


Text

Technical Specification 5.6.8 Oaps 102-07366-TNW /M DD October 26, 2016 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Palo Verde Nuclear Generating Station (PVNGS) Unit 1 Docket No. STN 50-528 License No. NPF-41 Palo Verde Nuclear Generating Station 5801 S. Wintersburg Road Tonopah, AZ 85354 Steam Generator Tube Inspection Report - Refueling Outage 19 Attached please find the PVNGS Unit 1 Steam Generator Tube Inspection Report prepared and submitted by Arizona Public Service Company (APS) pursuant to Technical Specification (TS)

Reporting Requirement 5.6.8. This report describes steam generator tube inspection and plugging results from the Unit 1 nineteenth refueling outage.

By copy ofthis letter, this submittal is being provided to the NRC Region IV Administrator and the PVNGS Senior Resident Inspector. No commitments are being made to the NRC by this letter.

Should you have questions regarding this submittal, please contact Michael D. Dilorenzo, Licensing Section Leader, at (623) 393-3495.

Sincerely, Thomas N. Weber Nuclear Regulatory Affairs Depa_rtment Leader TNW/MDD/CJS/af Attachment cc:

(with attachment)

NRC Region IV Regional Administrator NRC NRR Project Manager for PVNGS K. M. Kennedy S. P. Lingam C. A. Peabody NRC Senior Resident Inspector for PVNGS A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Diablo Canyon
  • Palo Verde
  • Wolf Creek

Attachment Unit 1 - 19th Refueling Outage Steam Generator Tube Inspection Report

/ /

/ /

I I i ~

Palo Verde Nuclear Generating S1ation UNrT1 U1R19 ARIZONA PUBLIC SERVICE P. 0. BOX 52034 PHOENIX, AZ 85072 Prepared by: Douglas B Hansen Leaverton,

~~;~~~:igned by Leaverton, wm..n Revl'ewed by*.

Warren L(V59783) :;:;,';,;~;:::";;,-::;:.~~:;:~..

- - - - - - -

  • D*te:2016.lo.2111:29"22-0TOO' Approved by:

Rad spinner,

~*~~R~~;;:~,:"~

1

!i~~:;;t;*~~Acv 6

nai

'Reason:Sys1~m&igineeringDepartment Mark A(776778)-"-~ -------

Commercial Service Date: 1-28-86 1 of 85 Date: 7-27-16 Date: -----

Report Date: ____

Table of Contents 1.0

SUMMARY

2.0 SCOPE OF EXAMINATIONS PERFORMED 3.0 ACTIVE DEGRADATION MECHANISMS 4.0 NOE TECHNIQUES UTILIZED 5.0 INDICATION

SUMMARY

6.0 TUBES PLUGGED 7.0 PLUG HISTORY 8.0 CONDITION MONITORING APPENDIX A - TUBE SUPPORT DIAGRAM, LEGEND, and ANALYSIS CODES APPENDIX B - SG 11

SUMMARY

DATA SHEETS APPENDIX C-SG 12

SUMMARY

DATA SHEETS APPENDIX D - PLI and PLP DA TA SHEETS APPENDIX E - PLUG MAPS APPENDIX F - FORM NIS - 1 2 of 85

UNITl STEAM GENERA TOR EDDY CURRENT Ul R19 Refueling Outage 1.0 Summary This report is intended to satisfy the requirements of PVNGS Technical Specifications 5.6.8 for the submittal of a Steam Generator Tube Inspection Report. The steam generator (SG) eddy current examination for the 19th refueling outage in Unit 1 (UIRI 9) was conducted during April 2016.

Mode 4 entry of Unit 1 was entered on May 10, 2016. The initial examination plan for both steam generators is listed in Table 1. This table summarizes the examinations performed for each of the various categories, examination types, extents, and the number of tubes or tube locations completed.

This was the fifth examination performed in Unit 1 following steam generator replacement in U1Rl2. This examination is considered a 100% full length tubing inspection.

The examinations resulted in a total of 23 tubes being plugged in SG 11, and 23 tubes being plugged in SG 12. A description of the previous plugging history is noted in Table 2, and Appendix E provides a map of all tubes plugged. It should be noted that the plugging criteria utilized during this outage again supports 2 cycles of operation (next scheduled eddy current examinations are for R21).

2.0 Scope of Examinations Performed The original examination plan was developed based on the "PVNGS Steam Generator Degradation Assessment" developed per PVNGS Procedure 81DP-9RC01 as required by NEI 97-06. In addition, possible damage mechanisms were reviewed along with the specific requirements set forth in Procedure 73TI-9RC01 and the PVNGS Technical Specifications.

The plan was finalized to include 100% bobbin examinations.

This original plan, along with the examinations performed as a result of bobbin indications noted, is su~m~!iz:ed _ _in Table 1 of this repof!'. _ _ _ ____ _

3.0 Active Degradation Mechanisms The only degradation noted during the examinations was determined to be wear. Section 8.0 contains further discussions relating to this mechanism. Table 2 summarizes the results into categories and Appendices B and C itemize all indications reported.

3 of 85

4.0 NDE Techniques Utilized The following table documents the eddy current techniques utilized during this outage:

BOBBIN Examinations Damage ETSS QUAL Extended BC BC Mechanism Location NO STATUS Applicability DET SIZE TECH Comments Wear BWs, VSs, 96004.1 SITE Tube y

y VoltDIFF

  • ote I ECs Rl 3 VALIDATED Proximity (not dented)

Aooendix Al Tube-to-Frees pan 13091.l QUALIFIED A

y A

Volt ABS Tube Wear Upper RO Appendix BI

  • ote I Bundle Wear Loose Part 2709 1.2 QUAUFIED Tubesheet y

N Volt DlFF

  • Note I R2 Appendix C l Transition ARRAY Examinations Damage ETSS QUAL Extended Mechanism Location NO STATUS Applicability DET SIZE TECH Comments 11956.3 SITE Wear BWs, ECs, R2 VALIDATED NA y

y X-Probe

  • Note I VSs 11956.4 Appendix DI R2 RPC Examinations Damage ETSS NO QUAL Extended Mechanism Location STATUS Applicability DET SIZE TECH Comments Wear BWs, ECs, 96910.1 QUALIFIED A

NA y

+POINT none VSs Wear Tube-to-Tube 2 1998.1 QUALIFIED A

A y

+POINT none Wear Frees pan 2790x QUALIFIED A

NA y

+POINT

  • Note I Loose Part Series ote 7 Tube-to-Tube Note I: The U IR 19 DA provides details for the qualification and use of these techniques The eddy current examinations were performed by Westinghouse Electric Company using the Core Star OMNI 200 eddy current instrument. Westinghouse Anser software was utilized to acquire the data along with the Pegasys robotic manipulator. This robot was configured with a dual guide tube in each of the hot and cold legs.

4 of 85

The tubing was examined with Core Star manufactured bobbin coil probes and Zetec array (X-Probe) and rotating coil (RC) style probes. Probe diameters were 0.580" to 0.610". X-Probe and/or Plus Point RC probes were used for the characterization of non-quantifiable or distorted bobbin indications.

Fiber optic cable was used from containment to the data acquisition room located at the PVNGS North Annex. Primary and secondary analysis was all performed on site. The Primary and Secondary Resolution Analysts, Independent Review Analysts, and data management were also located at PVNGS in the North Annex. Westinghouse provided the data acquisition and primary data analysis. Areva International, Inc. provided the secondary data analysis.

Each individual from Westinghouse and Areva International, Inc. who performed data analysis was required to complete and pass a PVNGS site specific Eddy Current Data Analysis Course as well as an associated performance and written examination. All individuals performing data analysis were also required to have Qualified Data Analyst (QDA) certification.

5.0 Indication Summary A detailed listing of the location and measured sizes (when applicable) of the eddy current indications recorded is included in Appendix B and C. A summary of these indication results is located in Table 2. In addition, Appendix A contains a reference drawing of steam generator support locations and report legend.

Appendix D contains a listing of the possible loose part (PLP) indications that were confirmed with rotating coil examinations. Note Section 8.0 for further discussion on the PLPs.

There were no indications that were identified as linear during this outage.

6.0 Tubes Plugged A summary of the tubes plugged is located in Table 2. A total of 23 tubes in SG 11 and 23 tubes in SG 12 were plugged this outage.

Appendix E contains a map that details the plugged tube location along with the previously plugged tubes.

7.0 Plug History A summary of the number and percentage of tubes plugged is also located in Table 2.

5 of 85

8.0 Condition Monitoring Tube Inspection Summary Per the Steam Generator Program, as defined in PVNGS Procedure 81DP-9RC01, a condition monitoring evaluation was conducted by PVNGS Engineering. The results of the eddy current examinations are provided in Section 5.0. An engineering evaluation of the as-found condition of inservice tubes did not reveal any degradation exceeding the threshold values for structural and leakage integrity. As such, all steam generator performance criteria were satisfied for Unit 1 Cycles 18 and 19. No tube pulls or in-situ pressure testing were required based on the results of the examinations.

Foreign Object Search and Retrieval (FOSAR)

Prior to and after sludge lancing activities, FOSAR was performed at the tubesheet elevation in the annulus region and the blowdown lane. The applicable requirements of Revision 3 of the EPRI Steam Generator Integrity Assessment Guidelines Section 10.5, Secondary Side Visual Inspections, were applied for the FOSAR inspections. FOSAR was also performed on the Flow Distribution Plate (FDP). No foreign object wear was found in either steam generator 11 or 12. Following is a summary of the foreign objects that were identified in each SG. Sludge rocks and scale and graphite are not discussed, since they are not considered as a threat to tube integrity.

SGll -Foreign object Summary Three foreign objects were found during FOSAR in SG 11. The first object was identified during the pre-sludge lance inspection. The object was found near tube Rl66C89 on the top of the tubesheet cold leg side and was removed via sludge lancing. No tube wear was associated with this object. The second object was a very small bristle that was identified on the top of the tubesheet hot leg side during an in bundle inspection of the kidney region. No tube wear was associated with this object. Due to its size and location in bundle, the object is not judged to be a threat to tube integrity.

The third object was identified several tube columns away from the annulus near tubes R61C190, R63Cl90, R65Cl90 and R67C190 on the top of the tubesheet cold leg side and was sized with dimensions of 2.25 inches by 0.116 inches by 0.25 inches. No tube wear was associated with this object. Eddy current testing (+point and X probe) was performed in the vicinity of the object it was determined that the object is non-metallic. Based on the location of the object, it is not considered to be in a high flow region and is not judged to be a threat to tube integrity. Per the PVNGS SG Program, trending of these locations will continue in future outages.

SG12 -Foreign object Summary The only foreign objects found in SG12 were some very small bristles found far in bundle on the top of the tubesheet hot leg side. The bristles were found during a partial in bundle inspection of the kidney region. Due to their size and location, these objects are not judged to be a threat to tube integrity. Per the PVNGS SG Program, trending of these locations will continue in future outages.

Blowdown Patch Plate Weld Inspection Summary Also included in the scope of the FOSAR effort was an inspection of the blowdown patch plate welds In SGI 1 and SG12 that were found to be cracked in Unit 2 during 2Rl5. The inspections confirmed that the weld material in the vicinity of the cracked weld on all 4 patch plates (2 per SG) is intact, and a loose parts concern is not being created. A previous evaluation concluded that, with the presence of the cracked welds, the patch plates in the Unit 2 SGs will continue to perform their design function and that the probability of loose parts being formed is remote. Thus, there is a very 6 of 85

low risk that the cracked welds will affect the structural or leakage integrity of tubes in these steam generators.

Sludge Lancing Summary Sludge Lancing was performed in 1Rl9. Little sludge was observed in the tubesheet annulus region and in the blowdown lane of both SGs. A total of 19 lbs of sludge was removed from SG 11 and 15.5 lbs of sludge was removed from SG 12.

Plug Inspections Summary The EPRI PWR Steam Generator Examination Guidelines require that a visual inspection of the previously installed steam generator plugs be performed to assess plug integrity. Additionally, the Examination Guidelines require a verification of the location and presence of existing in-service plugs. The conduct of the plug location and integrity verification was performed in lRl 9 per the applicable procedure. A review of the inspection results indicated that all plugs were accounted for and no evidence of potential plug leakage was identified.

Channel Head Inspection Summary A channel head inspection was also performed in response to Westinghouse Engineering Nuclear Safety Advisory Letter (NSAL) 12-1, dated January 5, 2012. The inspection identified no degradation.

7 of 85

TABLE 1 EXAMINATION

SUMMARY

SCOPE DESCRIPTION SG It SG12 Exam Description Extents Scope Scope FULL LENGTH TEC-TEH 11 938 10682 BOBBI COLD LEG TEC-VS3 554 1791 BOBB IN HOT LEG TEH-VS3 554 1791 BOBBIN HOT LEG VARIOUS 262 341 ARRAY COLD LEG VARIOUS 111 94 ARRAY HOT LEG VARIOUS 20 16 RC COLD LEG VARIOUS 15 6

RC Notes:

1. ARRAY probe technology utilized the X-Probe
2. RC-rotating coil examinations were performed for historical comparisons 8 of 85

TABLE2 INDICATION

SUMMARY

DAMAGE STEAM GENERA TOR STEAM GENERA TOR MECHANISM 11 12 Tubes Indications BW vs EC T ubes Indications BW vs EC WEAR 1%- 19%

561 605 324 219 62 577 624 265 293 66 20% - 29%

53 55 34 15 6

37 40 18 20 2

30% - 39%

5 5

4 I

0 4

4 3

I 0

2'. 40%

0 0

0 0

0 3

3 3

0 0

PLUGGED (23)

(23)

Possible Loose Parts

~

(Array Coil)

PLI 0

0 PLP 6

I PLUGGED (0)

(0)

PREVENTATIVE (0)

(0)

PLUGGED

( 23)

( 23)

TOTAL PLUGGED I

( 111 I 0.9%)

( 130 I 1.0%)

O/o NOTES:

1. Numbers in (X) are tubes numbers plugged in each category
2. The "Tubes" column above represents Bobbin Coil results for the number of tubes; using the largest wear indication
3. The "Indications" column above represents Bobbin Coil results for the number of wear indications LEGEND:

BW - batwing VS - vertical strap EC - eggcrate 9 of 85

APPENDIX A TUBE SUPPORT DIAGRAM, LEGEND, and ANALYSIS CODES 10 of 85

PVNGS Steam GeneratOI Center of 08H to 08C Row 1 - 17.415 Row 2 - 19.736 Row 3 - 22.056 Row 4 - 24.377 Row 5 - 26.698 Row 6 - 29.019 REPLACEMENTS 26 "

Typical Spacing BW1 VS1 V 2 VS3 V54 VS5 08H 35.95" 07H 35.95" 06H 35.95" 05H 35.95" 04H 36.34" 24" 03H 36.33" 28.125" 02H 36.33" 28.125" 32.25" 01H 20" 16.5" 25"

  • 0.25" c:l..t Inlet Outlet 11 of 85 08C 07C 06C 05C 04C 03C 02C 01C FOP

ROW:

COL:

VOLTS:

DEG:

IND:

PER or PCT:

CHN:

LOCN:

CRLEN:

CRWID:

CEG:

BEGT and ENDT:

PDIA:

PTYPE:

CAL:

L:

COM:

LEGEND Indicates the row number of a given tube.

Indicates the column number of a given tube.

Indicates the peak-to-peak voltage of a given indication response.

The measured phase angle of a given indication response.

Indicates the analysis code or PCT for percent The percent through_ the tube wall of a given indication Indicates the channel used to make the call Gives indication location at INCH! to INCH2 relative to known landmarks such as supports, vertical straps, and batwings. Typical location codes are as follows:

  1. 1 Vertical Strap................................ VS 1
  1. 1 Batwing......................................... BWl
  1. 1 Support Plate in Hot Leg.............. OlH
  1. 7 Support Plate in Cold Leg............. 07C Top Tube Sheet Cold Leg.................. TSC Tube End Hot Leg.............................. TEH Tube End Cold Leg............................ TEC Indicates the flaw length, used to identify the length of a wear indication Indicates the flaw width, typically used for cracks only Indicates the flaw length, typically used for cracks only Indicates the beginning and of the test; together they document the examination extent Documents the probe diameter Documents the probe type Indicates calibration number Indicates the leg the examination was conducted from This comment field is utilized to document comments 12 of 85

Analysis Codes:

Absolute Drift.................................................................... ADI Bulge.................................................................................. BLG Dented Buff Mark.............................................................. DBM Deposit............................................................................... DEP Dent.................................................................................... DNT Data Quality Acceptance.................................................... DQA Distorted Support Signal With Indication.......................... DSI Distorted Top ofTubesheet With Indication..................... DTI Geometric Indication.......................................................... GEO History Review.................................................................. HR ID Chatter........................................................................... IDC Indication Not Found......................................................... INF Indication Not Reportable.................................................. INR Multiple Axial Indication................................................... MAI Manufacturer Burnishing Mark.......................................... MBM Multiple Volumetric Indication.......................................... MVI No Detectable Defect......................................................... NDD No Discontinuity Found..................................................... NDF Non-Quantifiable Indication.............................................. NQI No Tube Sheet Expansion.................................................. NTE Obstructed.......................................................................... OBS Over Expanded................................................................... OXP Previous Bobbin Call............................. :........................... PBC Possible Deposit................................................................. PDP Positive Identification........................................................ PIO Positive Identification Verified.......................................... PIV Possible Loose Part with Indication................................... PLI Possible Loose Part............................................................ PLP Previous RC Call................................................................ PRC Possible Support Anomaly................................................. PSA Possible Support Indication............................................... PSI Permeability Variation Noise............................................. PVN Retest Bad Data.................................................................. RBD Retest Identification Check................................................ RIC Retest with Magnetic Bias RC Probe................................. RMB Single Volumetric Indication.......................................... ;.. SVI Senior (Lead) Analysis Review......................................... SR Sludge................................................................................ SLG To Be Plugged.................................................................... TBP Volumetric Indication........................................................ VOL Quality Codes:

Cross talk........................................................................... QCT Insufficient extent tested.................................................... QET Sudden drift of signal base line.......................................... QDO Less than the required samples.......................................... QDR Quality issue for ADS or RTAA........................................ QDS System out of balance........................................................ QOS Spiking or parasitic noise................................................... QPN One or more required channels without signal................... QPS Saturated signals in the tube............................................... QSS Probe speed varies.............................................................. QSV Historical indications not present....................................... QPV Tube number in question.................................................... QTI 13 of 85

APPENDIXB STEAM GENERATOR 11

SUMMARY

DATA SHEETS 14 of 85

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+---c+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

48 9

48 13 50 52 33 61 63 83 83 28 67 79 13 13 14 14 14 16 16 17 18 18 98 19 55 20 30 21 34 21 36 21 80 21 85 22 93 22 97 22 97 22 60 23

.28 83 PCT 10

.11 90 OSI

.35 78 PCT 12

.27 78 PCT 10

.27 147 PCT 10

.30 25 PCT 10

.47 70 PCT 15

.29 62 PCT 10

.43 63 PCT 13

.32 156 PCT 11

.33 86 PCT 11

.27 116 PCT 10

.31 145 PCT 10

.29 60 PCT 10

.27 136 PCT 10

.30 142 PCT 10

.47 106 PCT 15

.50 86 PCT

.43 138 PCT

.34 123 PCT

.34 66 PCT

.28 75 PCT

. 22 105 PCT 15 14 11 11 10 8

P2 VS3 Pl 09C P2 VS3 P2 VS3 P2 VS3 P2 BW2 P2 VS4 P2 VS3 P2 BW2 P2 VS3 P2 BW2 P2 BWl P2 BW2 P2 BWl P2 VS3 P2 VS3 P2 VS3 P2 VS4 P2 BW2 P2 BW2 P2 BWl P2 BW2 P2 VS3

-. 81

-. 43

-. 81

-.93

-. 83

.83

1. 04
1. 01

-. 78

-. 70

.96

1. 03

-. 87 1.88

-. 78

-. 75

-. 90

1. 01

.75

.76

.93

.90

-. 68 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEC TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEC

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

. 610 SBAY2

. 610 SBAY2

. 610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl 204 c 228 204 c 204 c 204 c 204 c 204 c 204 c 201 c 201 c 204 c 204 c 202 c 203 c 203 c 204 c 204 c 204 c 230 c 204 c 204 c 204 c 204 c 229 c 184 185 186 160 146 145 56 56 125 8

78 26 47 77 79 80 16 37 33 30 30 11

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

1 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

J ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

70 23 90 23 94 23 61 24 81 24 85 24 87 24 99 24 101 24 103 24 107 24 98 25 81 26 90 27 81 28 87 28 103 28 115 28 86 29 86 29 96 29 106 29 106 29

.30 87 PCT 12

.27 57 PCT 12

.29 147 PCT 10

.28 133 PCT 12

.30 152 PCT 10

.33 142 PCT 11

.30 150 PCT 10

.26 92 PCT 10

.37 133 PCT 13

.27 97 PCT 10

.31 126 PCT 11

.23 147 PCT 11

.29 95 PCT 12

.25 85 PCT 11

.34 81 PCT 11

.31 96 PCT 13

.32 94 PCT 11

.22 141 PCT 10

.24 91 PCT 10

.41 122 PCT 16

.36 131 PCT 15

.23 128 PCT 11

.21 129 PCT 10 P2 VS2 P2 VS2 P2 BWl P2 VS2 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BWl P2 VS2 P2 VS2 P2 10H P2 BW2 P2 VS2 P2 VS3 P2 VSl P2 VS2 P2 VS3 P2 BW2 P2 VS2 P2 VS4 1.00

-. 97

-.84

-. 72

.72

.84

.82

.99

1. 01

.98 1.03

.85

.79

-. 92

.86

.69

-1. 02

.89

.77

. 78

-. 77.

.78

.74 VS3 TEH VS3 TEH TEC TEH VS3 TEH VS3 TEC VS3 TEC VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH VS3 TEH VS3 TEC VS3 TEH TEC TEH TEC TEH VS3 TEH VS3 TEH TEC TEH TEC TEH TEC TEH

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAYl

.610 NBAZl

.610 NBAZl

.610 SBAYl

.610 SBAYl

.610 SBAYl 35 H

35 H

26 H

35 H

230 c 230 c 230 c 26 H

26 H

26 H

26 H

27 H

35 H

35 H

230 c 35 H

26 H

27 H

35 H

35 H

27 H

27 H

27 H

5 15 47 58 31 29 28 43 42 41 39 48 22 27 56 38 23 13 50 50 29 34 34

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

J ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

2 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

112 29 118 29 31 30 45 30 105 30 109 30 48 31 56 31 12 33 99 34 117 34 90 35 109 36 109 36 86 37 116 37 128 37 128 37 101 38 111 38 113 38 113 38 115 38 90 39

.31 83 PCT 11

.31 95 PCT 11

.26 114 PCT 9

.21 69 PCT 8

.21 69 PCT 10

.25 102 PCT 11

.31 154 PCT 10

.34 136 PCT 10

.26 153 PCT 9

.22 65 PCT 10

.28 134 PCT 10

.75 98 PCT 23

.63 114 PCT 18

.44 132 PCT 14

.29 148 PCT 10

.22 31 PCT 10

.79 113 PCT 21

.47 120 PCT 15

.24 62 PCT 11

.22 144 PCT 10

.97 106 PCT 23

.29 118 PCT 10

.31 108 PCT 10

.29 52 PCT 10 P2 BW2 P2 BW2 P2 VS3 P2 BWl P2 BW2 P2 VS3 P2 BWl P2 BWl P2 08H P2 BW2 P2 VS2 P2 10H P2 VS2 P2 VS3 P2 VS4 P2 BWl P2 VS2 P2 VS3 P2 VS2 P2 BWl P2 VS2 P2 VS3 P2 VS2 P2 10H

. 74

.86

.81

-.88

-1.04

-. 95

-1.09

-1.54

.90 1.11

-1.18

-1.00

-.99

.75

-.84

-.49

. 71

. 78

.63 1.26

-. 85

-1.21

-. 99

-1.04 TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 NBAZl

. 610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl 26 H

13 22 H

236 211 c 79 211 c 86 27 H

21 27 H

19 213 c 87 213 c 83 209 c 26 27 H

68 24 H

175 37 H

195 26 H

98 26 H

98 231 c 15 25 H

178 22 H

232 22 H

232 27 H

88 27 H

93 24 H

169 24 H

169 24 H

168 32 H

107

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

3 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 8EGT ENDT PDIA PTYPE CAL L

!DX UT Ill UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

118 39 81 115 90 108 63 130 121 121 121 121 121 40 40 41 41 42 43 44 44 44 44 44 125 44 137 44 126 45 119 46 121 46 56 47 65 48 67 48 131 48 135 48 90 49 89 50

. 30

.35

.31

.37

.21

.35

.29 1.26

.48

.22

.25 54 PCT 113 PCT 106 PCT 94 PCT 124 PCT 27 PCT 81 PCT 104 PCT 71 PCT 31 PCT 28 PCT TBP 10 14 13 12 10 11 12 30 17 10 11

.62 88 PCT 20

.23 75 PCT 8

.23 119 PCT 10

.56 116 PCT 16

.63 110 PCT 17

.28 145 PCT 10

.30 127 PCT 12

.22 75 PCT 10

.40 84 PCT 15

.23 89 PCT 10

.30 36 PCT 10

.28 91 PCT 10 P2 BW2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 VS2 VS3 10H BW2 BW2 VS2 VS2 VS3 VS4 BW2 P2 VS2 P2 VSl P2 VS2 P2 VS2 P2 VS2 P2 BWl P2 BWl P2 BWl P2 BW2 P2 BW2 P2 10H P2 VS2

-1. 00

.53

-1.10

-1.22

-2. 01

.99

.93

.62

.80

-.83

1. 03

-1. 04

.44 1.19

-. 90

-1. 04

-1. 75

.98

-.68

.96

1. 00

-1. 50

-.88 TEC TEH VS3 TEH TEC TEH VS3 TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC VS3 TEH VS3 TEH TEC TEH TEC TEH VS3 TEH VS3 TEH

.610 SBAY2

.610

.610

.610

.610

.610

.610

.610

.610

.610

.610

.610 NBAZl SBAYl NBAZl SBAYl SBAY2 SBAYl SBAYl SBAYl SBAYl SBAYl NBAZl

.610 SBAYl

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

. 610 SBAYl

.610 SBAYl

.610 NBAZl

.610 NBAZl 24 H 33 25 32 27 201 23 25 25 25 25 40 H

H H

H c

H H

H H

H H

25 H

160 117 174 103 95 17 213 156 156 156 156 23 154 22 H

221 25 H

147 24 H

136 24 H

135 214 c 25 33 H

62 33 H

63 25 H

130 25 H

128 32 H

51 32 H

46

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UT! L2 !

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

4 ST Max

SG - 11 Calls of Interest Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

129 50 126 51 126 51 130 51 144 51 65 52 123 52 127 52 135 52 102 53 122 53 122 53 126 53 65 54 97 54 107 54 111 54 113 54 119 54 127 54 129 54 143 54 143 54

.31 72 PCT

.28 129 PCT

.35 104 PCT 10 10 12

.84 108 PCT 21

.23 83 PCT 10

.28 123 PCT 13

.22 98 PCT 10

.27 68 PCT 12

.39 100 PCT 15

.39 143 PCT 15

.31 130 PCT

.25 60 PCT

.37 103 PCT 13 11 14

.27 72 PCT 10

.21 70 PCT 10

.21 133 PCT 10

.37 74 PCT 15

.88 116 PCT 22 1.28 114 PCT 27

.33 128 PCT 11

.40 24 PCT 13

.28 107 PCT 12

.22 128 PCT 10 P2 VS2 P2 VS3 P2 VS4 P2 VS3 P2 VS5 P2 BWl P2 VSl P2 VS2 P2 VSl P2 BWl P2 VSl P2 VS2 P2 VS3 P2 BWl P2 BW2 P2 BWl P2 VS3 P2 VS4 P2 VS4 P2 VS2 P2 VSl P2 VS3 P2 VS4

-.86

1. 09

-1.09

1. 01

-1.22

.91

-.90

.33

-1.07

-.66

.49

.97

.97

1. 00
1. 02

-1.26

-1.04

.91

.87

.28

-.88

-.84

.86 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

. 61QJ SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

. 61QJ SBAYl

. 61QJ SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 61QJ SBAY2

.610 SBAYl

.61QJ SBAYl 24 H

24 H

24 H

108 97 97 24 H

99 23 H

171 29 H

29 25 H

109 25 H

107 25 H

103 27 H

154 25 H

25 H

25 H

91 91 93 227 c 272 27 H

161 27 H

166 27 H

168 24 H 89 24 H

86 24 H

82 24 H

81 27 H

5 27 H

5

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

! ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

5 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

90 55

.27 41 PCT 11 P2 10H

-1.20 VS3 TEH

.610 NBAZl 37 H

86 120 55

.44 118 PCT 13 P2 BWl

-1.10 TEC TEH

.610 SBAY2 24 H

63 U9 56

.24 24 PCT 10 P2 BWl

.60 TEC TEH

.610 SBAYl 25 H

82 121 56

.24 42 PCT 10 P2 VS3

.98 TEC TEH

.610 SBAYl 25 H

81 133 56

.25 127 PCT 11 P2 UC

-1. 71 TEC TEH

.610 SBAYl 25 H

76 141 56

.35 143 PCT 11 P2 VS3

-. 79 TEH TEC

.610 SBAY2 216 c 118 90 57

.99 89 PCT 24 P2 10H

-1.25 VS3 TEH

.610 NBAZl 38 H

39 65 58

.30 129 PCT 10 P2 VS3

-. 69 TEH TEC

.610 SBAY2 201 c 8

93 58

.24 143 PCT 11 P2 VS4

-. 83 TEC TEH

.610 SBAYl 27 H

178 137 58

.47 152 PCT 14 P2 VS2

.92 TEH TEC

.610 SBAY2 216 c 138 62 59

.30 35 PCT 11 P2 BWl

-. 85 TEH TEC

.610 SBAYl 225 c 40 68 59

.27 53 PCT 10 P2 BWl

-. 90 TEH TEC

.610 SBAYl 227 c 242 100 59

.31 96 PCT u

P2 BWl

-. 87 TEC TEH

.610 SBAY2 28 H

8 132 59

.26 103 PCT 10 P2 llH

-. 23 TEH TEC

.610 SBAY2 217 c 148 107 60

.25 102 PCT 10 P2 BWl

-1.42 TEC TEH

.610 SBAY2 28 H

16 125 60

.25 124 PCT 11 P2 VSl

-. 78 TEC TEH

.610 SBAYl 25 H

59 137 60

.45 131 PCT 14 P2 VSl

-.84 TEH TEC

.610 SBAY2 216 c 143 108 61

.35 142 PCT 15 P2 BWl

-1.75 TEC TEH

.610 SBAYl 29 H

12 120 61

.25 53 PCT 11 P2 BWl

-. 76 TEC TEH

.610 SBAYl 25 H

47 132 61

.22 85 PCT 10 P2 UH

-1.36 TEC TEH

.610 SBAYl 25 H

53 152 61

.36 144 PCT 13 P2 BW2

-1. 01 TEH TEC

.610 SBAY2 217 c 91 133 62

.68 129 PCT 18 P2 UC

-.24 TEC TEH

.610 SBAY2 24 H

29

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

6 ST Max

8.

CXl U1 SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UT! L2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

139 62

.35 59 PCT 11 P2 VSl

-.96 TEC TEH

.610 SBAY2 24 H

27 98 63

.28 62 PCT 10 P2 BWl

-. 85 TEH TEC

.610 SBAYl 227 c 146 100 63

.28 63 PCT 10 P2 BWl

-1.05 TEH TEC

.610 SBAYl 227 c 145 132 63

.26 101 PCT 9

P2 llH

-1. 75 TEC TEH

.610 SBAY2 24 H

23 144 63

.35 57 PCT 13 P2 VS4

-. 74 TEH TEC

.610 SBAY2 217 c 130 154 63

.24 133 PCT 10 P2 BW2

-. 96 TEH TEC

.610 SBAY2 217 c 89 95 64

.32 101 PCT 11 P2 BWl

-. 78 TEH TEC

.610 SBAYl 227 c 175 97 64

.32 120 PCT 11 P2 BWl

1. 08 TEH TEC

.610 SBAYl 227 c 174 99 64

.30 89 PCT 10 P2 BWl

-. 82 TEH TEC

.610 SBAYl 227 c 173 113 64

.25 124 PCT 11 P2 BWl

.85 TEC TEH

.610 SBAYl 25 H

42 129 64

.95 90 PCT 26 P2 VS3

-. 87 TEC TEH

. 610 SBAYl 25 H

34 153 64

.28 113 PCT 11 P2 VS2

-1.08 TEH TEC

.610 SBAY2 217 c 106 118 65

.31 56 PCT 13 P2 BWl

-.80 TEC TEH

. 610 SBAYl 25 H

17 122 65

.28 50 PCT 12 P2 BWl

-.89 TEC TEH

.610 SBAYl 25 H

19 81 66

.29 71 PCT 10 P2 BWl

-.89 TEH TEC

.610 SBAYl 227 c 121 103 66

.39 73 PCT 13 P2 BWl

1. 00 TEH TEC

.610 SBAYl 227 c 132 111 66

.30 133 PCT 10 P2 VS3

.82 TEH TEC

.610 SBAYl 227 c 136 149 66

.29 153 PCT 11 P2 VS2

.23 TEH TEC

.610 SBAY2 217 c 110 120 67

.29 71 PCT 10 P2 BWl

-1. 31 TEC TEH

.610 SBAY2 22 H

170 132 67

.43 73 PCT 14 P2 llH

-1. 78 TEC TEH

.610 SBAY2 22 H

176 25 68

.08 101 NQI Pl VS3 2.32 TEH TEC

.610 SBAYl 225 c 128 115 68

.34 85 PCT 14 P2 VS4

1. 05 TEC TEH

. 610 SBAYl 29 H

25

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UT! L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

7 ST Max

SG - 11 Calls of Interest Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UT Ill UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

129 68 133 68 90 69 130 69 130 69 47 70 97 70 119 70 129 70 62 71 90 71 92 71 116 71 126 71 162 71 73 73 73 72 72 72 157 72 128 73 41 74 45 74 47 74 59 74

.28 63 PCT 11

.30 96 PCT 11

.36 94 PCT 10

.48 53 PCT 16

.37 117 PCT 13

.31 82 PCT 11

.44 110 PCT 14

.46 78 PCT

.27 61 PCT

. 24 116 PCT

.19 65 PCT

.28 105 PCT

.27 108 PCT

.35 44 PCT

.30 132 PCT

.23

.17

.11 155 NQI 137 NQI 128 NQI

.48 55 PCT

.30 141 PCT

.21 44 PCT 14 10 11 7

11 11 13 10 16 10 10

.21 75 PCT 10

.21 39 PCT 10

.29 102 PCT 11 P2 VS4 P2 BWl P2 10H P2 VSl P2 VS3 P2 BWl P2 BWl P2 VS2 P2 VS2 P2 BWl P2 10H P2 BW2 P2 VS2 P2 BW2 P2 BW2 Pl FDP Pl TSC Pl TSC P2 VSl P2 VS2 P2 VS3 P2 VS3 P2 BWl P2 BWl

-. 93

-.89

-1.00

-. 71

.94

.93

-.72

-.89

-. 94

-.94

-1.11

-.95 1.05

-. 82

.87 12.32 6.05 8.25

-. 75

.88

.74

.68

.84

.87 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAYl

. 610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 217 c 217 c 226 c 217 c 217 c 227 c 227 c 22 H

22 H

29 H

227 c 217 c 217 c 217 c 216 c 226 c 226 c 226 c 217 c 216 c 2

H 34 32 79 35 35 22 77 163 158 27 54 72 58 53 78 54 54 54 82 54 58 2

H 192 2

H 155 1

H 134

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

8 ST Max

SG -

11 Calls of Interest Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 08:22:19

+ *- - - - + - - - - + - - - - - - - - - + - - - - + - - - - + - - - - + - - - - - - - + - - - - - + - - - - + - - - - - - - - - + - - - - - - - - - + - - - - + - - - - + - - - - - - + - - - - - - + - - - - - - + - - + - - - - - + - - - - - - - - - + - - - - - - - - - +

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTIL2 I

+----+----+---------+----+----+----+c------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

67 74 165 74 34 75 40 75 46 75 48 75 90 75 134 75 164 75 35 76 47 103 103 76 76 76 163 76 165 76 90 77 140 77 164 77 166 77 125 78 163 78 30 79

.72 136 NQI

.24 150 NQI

.22 90 PCT 10

.31 90 PCT 13

.21 98 PCT 10

.25 41 PCT 11

.34 103 PCT 12

.40 116 PCT 13

.75 75 PCT 21

.21 49 PCT

.82 93 PCT

.24 81 PCT

.23 151 PCT 10 24 10 10 1.29 100 PCT 28

.55 109 PCT 17

.40 78 PCT 14

.26 149 PCT 10

.47 68 PCT 15

.31 87 PCT 11

.30 61 PCT 11

.37 93 PCT 13

.25 89 PCT 11 Pl TSH Pl TSH P2 BWl P2 BWl P2 BWl P2 VS3 P2 10H P2 BWl P2 BW2 P2 VS3 P2 BWl P2 BWl P2 VS4 P2 BW2 P2 BW2 P2 10H P2 VSl P2 BWl P2 BW2 P2 VS5 P2 BW2 P2 VS3

.37

.86

-. 87

-. 85

-1.08

-1.11

-1. 51

-.60

-. 74

.75

.94

-. 80

.77

-.84

-. 79

-1. 36

-.82

.99

-. 79

-.88

.85

-.84 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC* TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 5

H 35 15 H

115 2

H 60 2

H 54 2

H 191 2

H 156 5

H 103 5

H 81 15 H

110 2

H 2

H 6

H 6

H 61 190 61 61 15 H

108 15 H

109 6

H 112 6

H 87 15 H

104 15 H

103 19 H

16 15 H

101 2

H 129

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

9 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UT! L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

38 79 44 79 50 79 90 79 132 79 47 80 77 80 115 80 115 80 167 80 32 81 36 81 60 81 78 81 82 81 118 81 120 81 122 81 124 81 136 81 164 81 168 81 43 82

.17 96 PCT 8

.29 117 PCT 12

.24 63 PCT 11

.27 85 PCT 10

.21 38 PCT 8

.58 83 PCT 20

.23 133 PCT 10

.27 94 PCT 11

.27 126 PCT 11 1.23 90 PCT 27

.31 67 PCT 13

.27 105 PCT 10

.56 97 PCT 19

.31 146 PCT 12

.23 124 PCT 10

.27 75 PCT 10

.24 89 PCT 11

.32 59 PCT 13

.22 56 PCT 10

.38 53 PCT 14

.39 46 PCT 13

.35 53 PCT 12

.40 110 PCT 13 P2 VS3 P2 VS3 P2 VS3 P2 10H P2 llH P2 BWl P2 VS4 P2 BWl P2 VSl P2 BW2 P2 BWl P2 BWl P2 BWl P2 VS2 P2 VS3 P2 VSl P2 BWl P2 BW2 P2 BW2 P2 VS2 P2 BWl P2 BW2 P2 BWl

-. 90

-. 74

.78

-1.44

-1. 23

.91

.60 1.04

-.94

-. 76

-.84

-. 92

.78

.71

.91

-. 80

-.84

.91

.94

.86

.91

-. 68

.93 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2 2

H 64 2

H 48 2

H 187 5

H i54 19 H

22 2

H 9

6 H

134 20 H

11 20 H

11 15 H

94 2

H 130 1

H 67 2

H 147 6

H 171 6

H 167 19 H

150 20 H

28 20 H

27 20 H

26 18 H 47 15 H

88 15 H

95 1

H 47

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

10 ST Max

01 a

co 01 SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

111 82 129 82 167 82 167 82 44 83 44 83 48 83 48 83 90 83 142 83 166 83 43 84 55 84 83 84 40 85 42 85 52 85 94 85 126 85 132 85 39 86 43 86 43 86 45 86

.27 123 PCT

.35 101 PCT

.38 115 PCT

. 49 100 PCT

.34 131 PCT

.40 117 PCT

.43 103 PCT

.22 84 PCT

.26 107 PCT

.28 124 PCT

.50 58 PCT

.21 135 PCT

.34 92 PCT 10 13 13 15 12 14 16 10 9

10 16 10 14

.31 98 PCT 12

.26 105 PCT 10

.21 65 PCT 10

.23 120 PCT 10

.30 51 PCT 12

.29 70 PCT 12

.22 154 PCT 10

.61 121 PCT 18

.36 105 PCT 14

.26 125 PCT 11

.38 96 PCT 15 P2 BWl P2 VS2 P2 BWl P2 BW2 P2 BWl P2 BWl P2 BWl P2 VS3 P2 10H P2 VS2 P2 BWl P2 BWl P2 BWl P2 VS2 P2 VS3 P2 BW2 P2 BW2 P2 BWl P2 BWl P2 llC P2 VS3 P2 BWl P2 VS3 P2 BWl

. 77

-. 61

-. 71

-.84

-1.02

.95

.73

-1.06

-1.06

-.86

.81

.80 1.68

.72

.85

.91

.84

-. 81

-.92

-1.46

-1.12

.82

.72

.92 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 5

H 191 19 H

40 15 H

82 15 H

82 1

H 1

H 2

H 2

H 46 46 45 45 5

H 205 17 H

15 15 H

80 2

H 69 2

H 182 6

H 190 1

H 71 2

H 111 2

H 14 6

H 214 21 H

64 21 H

61 1

H 117 2

H 110 2

H 110 2

H 71

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

11 ST Max

N CJ)

Q, (JO c.n SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

49 86 153 86 42 87 44 87 46 87 48 87 146 87 41 88 43 88 43 88 45 88 45 88 47 88 75 88 75 88 83 111 161 42 44 44 44 46 48 88 88 88 89 89 89 89 89 89

. 31 118 PCT

.33 131 PCT

. 58 117 PCT

. 28 114 PCT

. 37 104 PCT

.46 116 PCT

.26 117 PCT

.46 116 PCT

.46 116 PCT

.39 130 PCT 11 12 17 12 14 15 10 15 15 13

.62 109 PCT 20 TBP

. 27 111 PCT

.26 123 PCT

.24 129 PCT

.26

.25

.37

.56

.62 2.09

.25

.29 141 PCT 87 PCT 76 PCT 117 PCT 125 PCT 111 PCT TBP 73 PCT 144 PCT 12 10 10 10 10 13 17 18 36 11 12 P2 BW2 P2 VS2 P2 BWl P2 BWl P2 BWl P2 09C P2 BWl P2 BWl P2 BWl P2 BW2 P2 BWl P2 BWl P2 BWl P2 VS2 P2 VS2 P2 BWl P2 VSl P2 BWl P2 BWl P2 BWl P2 BWl P2 09H

-. 97

-. 93

-. 83

.80

.84

-. 98

-. 77

-. 98

.89

-.89

.79

.88

.83

.80

.64

-1. 15

-.89

-1.03

-1.00

.77

-.95

.82 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH

.610 SBAY2

. 610 SBAY2

. 610 SBAY2

.610 SBAY2

. 610 SBAY2

. 610 SBAY2

. 610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610

.610

.610

.610

.610

.610

.610 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 NBAZl SBAY2 SBAY2 1

H 12 15 H

208 1

H 73 2

H 2

H 1

H 15 H

1 H

1 H 1

H 2

H 40 H

2 H

109 72 42 193 116 74 74 108 21 73 6

H 238 6

H 238 6

6 15 1

1 1

40 2

2 H

H H

H H

H H

H H

242 256 56 115 75 75 22 107 74

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

12 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 2!il16!il4!ill

!il4/25/2!il16 !il8:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

82 89 14!il 89 142 89 144 89 144 89 45 9!il 167 9!il 167 9!il 46 91 46 91 48 48 48 8!il 82 91 91 91 91 91 9!il 91 126 91 13!il 91 136 91 45 92 47 92 47 92 59 92 l!il3 92 l!il7 92

.4!il 96 PCT 14

.22 91 PCT l!il

.25 44 PCT 11

.24 49 PCT l!il

.26 64 PCT 11

.62 88 PCT 18 1.16 99 PCT 27

.34 87 PCT 12

.34 142 PCT 12

.27 84 PCT l!il

.26 67 PCT

.22 42 PCT

.38 88 PCT

.75 l!il9 PCT

.39 9!il PCT

.17 68 PCT

.27 83 PCT 11 l!il 15 2!il 13 7

l!il

.27 5!il PCT l!il

.28 76 PCT l!il

.27 115 PCT l!il

.71 l!il7 PCT 2!il TBP

.21 75 PCT l!il

.25 44 PCT 11

. 26 l!il!il PCT 11 P2 BWl P2 BWl P2 BWl P2 BWl P2 BW2 P2 BWl P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 VS3 P2 BW2 P2

!il9C P2 BWl P2 VS3 P2 l!ilC P2 VS2 P2 BWl P2 VSl P2 BWl P2 BWl P2 VS2 P2 VS2 P2 BWl

-.84

.91

.96 1.!il5

-. 6!il

.86

-.86

-.13

-. 92

l. l!il

-. 87

.9!il

-. 43

-.88

.76

-1. 63 l.!il!il l.!il5

-. 25

.83

. 77

-. 35

.71

-1.82 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH

.61!il SBAY2

.61!il SBAYl

.61!il SBAYl

.61!il SBAYl

.61!il SBAYl

.61!il SBAY2

.61!il SBAY2

.61!il SBAY2

.61!il SBAY2

.6l!il SBAY2

. 61!il

. 61!il

. 61!il

. 61!il

.61!il SBAY2 SBAY2 SBAY2 SBAY2 SBAY2

.61!il SBAY2

.6l!il SBAY2

.6l!il SBAY2

.61!il SBAY2

.61!il SBAY2

.61!il SBAY2

.6l!il NBAZl

.61!il SBAY2

.61!il SBAY2

.6l!il SBAY2 6

H 272 16 H

64 16 H

63 16 H

62 16 H

62 1

H 76 15 H

42 15 H

42 1

H 77 1 H 77 2

2 2

7 7

H H

H H

H 7

H 19 H

l!il5 l!il5 l!il5 44 43 39 ll!il 19 H

l!il8 15 H

173 1

H 113 1

H 78 4!il H

2!il 2

H 21 8

H 23 8

H 25

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

13 ST Max

N co

~

co

(.l1 SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

113 90 132 168 47 47 167 48 48 48 68 92 93 93 93 94 94 94 95 95 95 95 70 95 47 96 49 96 49 96 127 96 159 96 48 97 120 97 49 98 51 98 107 98 115 98 143 98

.35 91 PCT

.17 40 PCT

.74 132 PCT

.36 120 PCT

.52 99 PCT

.63 128 PCT

.52 90 PCT

.27 49 PCT

.78 108 PCT TBP

.36 99 PCT

.32 146 PCT

.32 135 PCT

.63 103 PCT

.36 124 PCT

.19 57 PCT

.24 119 PCT 14 8

23 12 16 18 16 10 21 12 11 13 18 12 9

11

.26 36 PCT 11

.23 51 PCT 10

.32 80 PCT 13

.23 121 PCT 9

.43 119 PCT 14

.37 107 PCT 13

.71 53 PCT 21 P2 VSl P2 10H P2 llC P2 BW2 P2 BWl P2 BWl P2 BW2 P2 VS3 P2 BW2 P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 VSl P2 VS2 P2 BWl P2 BWl P2 BWl P2 BW2 P2 VS4 P2 VS2 P2 VSl

-.82

-1.32

-1.68

-. 85

.08

.91

.79

-. 95

.93

-1. 25

-.92

-. 78

-. 80

.89

.26

-.80 1.94

-.94

.96

-. 95

.80

-1.00

.42 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAYl

.610

.610

.610

.610

.610

.610

.610

.610

.610

.610 SBAY2 SBAYl SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 NBAZl SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 21 H

8 21 15 1

1 15 1

1 235 7

H H

H H

H H

H H c H

7 H

4 H

1 H

1 H

21 H

16 H

4 H

21 H

4 H

1 H

7 H

19 H

14 H 5

39 17 28 111 111 20 110 110 14 101 100 23 109 109 34 28 22 45 21 107 125 140 185

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

14 ST Max

N l.D SG - 11 Calls of Interest Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

56 99 56 99 110 99 128 99 168 99 51 100 169 100 171 100 171 100 171 100 62 101 106 101 118 101 146 101 168 101 170 101 170 101 115 102 115 102 171 102 50 103 60 103 88 103 128 103 142 103

.24 70 PCT

.55 60 PCT

.26 127 PCT

.36 78 PCT

.22 153 PCT

.21 59 PCT

.65 95 PCT

.44 90 PCT

.72 105 PCT

.36 82 PCT

.35 104 PCT

.27 43 PCT

.28 73 PCT

.38 129 PCT 11 19 10 13 9

10 19 14 20 12 12 11 12 13

.81 71 PCT 22

.38 80 PCT 13

.66 80 PCT 19

.86 117 PCT 22

.78 114 PCT 21

.39 61 PCT 14

.41 110 PCT 13

.25 45 PCT 11

.32 94 PCT 11

.50 98 PCT 15

.42 39 PCT 14 P2 BWl P2 VS3 P2 BWl P2 VSl P2 01C P2 BWl P2 VS5 P2 02C P2 02C P2 01C P2 VS3 P2 BWl P2 BW2 P2 VS2 P2 01C P2 01C P2 01C P2 VS3 P2 VS4 P2 01C P2 BWl P2 BWl P2 BWl P2 VS3 P2 VS4

-1.79

-.86

-.60

1. 03

.08

.88

.71

-.88

.08

.10

-.86

-1. 71

.83

-1.11

-. 97

-.13

.83 1.16

-. 83

.72

.85

-. 82

-. 82

. 77

.95 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610

.610 SBAY2 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 2

H 2

H 7

H 19 H

14 H 4

H 15 H

15 H

15 H

15 H

1 H

8 H

21 H

13 H

15 H

15 H

15 H

22 H

22 H

14 H

3 H

2 H

7 H

22 H

14 H

97 97 129 168 158 19 134 133 133 133 28 129 84 148 131 132 132 7

7 125 20 93 189 20 110

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

15 ST Max

w 0

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

150 103 168 103 170 47 47 47 103 104 104 104 49 104 49 1(1)4 51 104 121 104 169 104 171 104 126 105 170 105 49 106 49 106 75 106 95 106 171 106 50 107 50 107 90 107 96 107 168 107

. 20 101 PCT

.43 47 PCT

.40

.38

.83 34 PCT 86 PCT 100 PCT TBP 8

15 14 15 24

.92 102 PCT 23 TBP

.40 121 PCT 13

. 25 127

.PCT 11 1.16 74 PCT 26

.26 134 PCT 10

.24 35 PCT 11

.39 45 PCT 13 1.06 101 PCT 28 TBP

.57 93 PCT 17

.26 105 PCT 10

.33 38 PCT 12

.35 69 PCT

.25 99 PCT 14 11

.29 31 PCT 12 1.02 111 PCT 25

.46 37 PCT 15 P2 10H P2 01C P2 01C P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 BW2 P2 01C P2 BWl P2 BW2 P2 BWl P2 VS3 P2 BWl P2 01C P2 BWl P2 VS3 P2 BWl P2 VS4 P2 BWl

-.13

.91

-. 70

-1.08

.90

-. 95

.77

-.89

-. 76

.78

-. 77

.88

-. 97

-. 90

-. 74

.80

.81

.75

-. 83

-. 85

-. 85 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610

.610

. 610

.610 SBAY2 SBAY2 SBAY2 NBAZl

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 61QJ SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 14 H

14 H 14 H 4

H 4

H 40 H

3 H

40 H

3 H

23 H

13 H

13 H

23 H

114 123 124 53 53 19 22 18 18 9

125 124 20 13 H

123 4

H 52 40 H

17 7

H 207 7

H 217 14 H

88 4

H 4

H 51 51 7

H 237 7

H 234 14 H 86

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

! ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

16 ST Max

-1

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UT! L2 j

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

49 108 49 108 51 108 53 108 53 108 83 108 85 108 46 109 46 109 46 109 50 109 52 109 49 110 49 110 51 110 53 110 74 111 138 111 164 111 166 111 168 111 168 111 47 112 97 112 103 112 1.42 107 PCT TBP

.30 104 PCT 1.00 100 PCT TBP

.28 59 PCT

.25 34 PCT 1.66 100 PCT

.43 123 PCT TBP

. 23 110 PCT

.44 98 PCT 32 12 24 12 11 32 14 10 16

.75 111 PCT 20 TBP

.34 58 PCT 14

.21 40 PCT 10

.25 39 PCT 10

.44 44 PCT 15

.35 20 PCT 13

.38 66 PCT 14

.39 25 PCT

.41 29 PCT

.45 100 PCT

. 20 111 PCT

.29 67 PCT 14 14 14 9

12 P2 BWl P2 BW2 P2 VS3 P2 BWl P2 BWl P2 BWl P2 BWl P2 VS3 P2 VS3 P2 BWl P2 BWl P2 BW2 P2 VS3 P2 VSl P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl

.88

-. 74

.66

.85

.93

-.99

-. 81

.71

.81

.96

.88

-.88

.79

.61

.77

-. 74

-.82

.85

.96

-. 87

.96 TEC TEH VS3 TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610

.610

.610

.610

.610

.610

.610

.610

.610

.610

.610

.610 SBAY2 NBAZl SBAY2 SBAY2 NBAZl SBAY2 SBAY2 SBAY2 SBAY2 NBAZl SBAY2 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 4

H 40 H

4 H

3 H

40 H

8 H

8 H

3 H

3 H

40 H

4 H

4 H

3 H

40 H

4 H

4 H

9 H

14 H

14 H

14 H

14 H 14 H

5 H

10 H

10 H

54 14 50 26 12 210 211 51 51 16 55 49 49 15 56 48 61 34 47 48 49 49 13 35 38

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UT! L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

17 ST Max

w N

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 j

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

151 112 157 112 165 112 44 113 44 113 48 113 48 113 58 113 132 113 168 113 170 113 43 114 43 114 47 114 55 114 57 114 131 114 167 114 42 115 48 115 50 115 132 43 43 43 115 116 116 116

.38 111 PCT 13

.35 116 PCT 12

.45 107 PCT 14

.79 118 PCT 21 TBP 1.02 100 PCT 26 TBP

.29 94 PCT 10

.16 77 PCT 8

.37 108 PCT 12

.28 73 PCT 10 1.33 117 PCT 28 TBP

.31 111 PCT

.26 125 PCT

.25 107 PCT

.37 97 PCT

.47 28 PCT

.27 46 PCT

.26 140 PCT

.34 76 PCT

.17 2.37

.27 33 PCT 106 PCT 110 PCT TBP 12 11 11 12 16 10 10 12 6

38 10 P2 llH P2 VS2 P2 BWl P2 BWl P2 09C P2 BWl P2 llH P2 BW2 P2 VS2 P2 BW2 P2 BWl P2 BWl P2 BWl P2 BW2 P2 BW2 P2 BW2 P2 VS3 P2 BWl P2 llH P2 BWl P2 BW2

-.15

-. 63

-. 86

-. 86

-1.65 2.65

-1.60

-.84

-. 91

-. 74

.96

1. 74 2.09
1. 06

-. 83

1. 01

.84

-. 93

-1.42

.83

-.84 TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610

. 610 SBAY2 SBAY2 SBAY2 NBAZl 13 H

13 H

13 H

5 H

40 H

6 H

235 c 3

H 23 H

13 H

13 H

5 H

235 c 6

H 4

H 4

H 22 H

14 H

5 H

6 H

3 H

22 5

5 40 H

H H

H 58 55 51 15 13 15 12 31 61 47 48 16 11 16 60 44 81 16 17 13 126 84 9

9 8

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 j

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

18 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

45 116 45 116 47 116 49 116 105 116 121 116 40 117 40 117 46 117 46 117 46 117 48 117 90 117 96 117 140 117 158 117 43 118 43 118 43 118 45 118 47 118 49 118 97 118 163 118 165 118

.58 123 PCT

.38 92 PCT

.35 133 PCT

.38 54 PCT

.23 61 PCT

.27 47 PCT

.28 90 PCT

.33 128 PCT

.21 142 PCT

.43 120 PCT

.42 130 PCT

.36 94 PCT

.24 59 PCT

.27 49 PCT

.47 96 PCT

.32

.47

.66 39 PCT 90 PCT 93 PCT TBP

.58 123 PCT

.31 60 PCT

.36 65 PCT

.37 116 PCT

.21 55 PCT

.21 35 PCT 18 14 13 13 10 11 10 12 9

15 15 12 10 11 15 11 16 20 19 11 12 13 10 10 P2 BWl P2 BW2 P2 BWl P2 BWl P2 BWl P2 VS2 P2 BWl P2 BW2 P2 BWl P2 BWl P2 VS3 P2 09C P2 10H P2 VS2 P2 VSl P2 VS3 P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 VS5 P2 VS5

.85

-. 74

-1.10

.96

-1.12

. 74

-.40

-.93

-1.28

-. 73

.81

-1. 21

-1. 71

-. 91

.65

.92

-1.01

.96

-1. 21

1. 01

.89

-. 82

.94

.82 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

. 610

.610

.610

. 610

. 610

.610

.610 SBAY2 SBAY2 SBAYl SBAY2 SBAY2 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610

.610 SBAY2 SBAY2 SBAY2 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 6

H 6

H 6

H 3

H 10 H

23 H

5 H

5 H

6 H

6 H

6 H

3 H

10 H

18 18 12 127 90 75 19 19 11 11 11 128 104 10 H

102 11 H

210 13 6

6 40 H

H H

H 7

20 20 11 6

H 10 3

H 129 3

H 123 9

H 137 12 H

201 12 H

200

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

19 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTIL2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - :-+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

169 118 40 119 42 119 42 119 48 119 48 119 90 119 132 119 132 119 39 120 39 120 39 120 41 41 41 41 120 120 120 120 43 120 73 120 111 120 151 120 38 121 38 121 38 121 40 121 42 121 42 121 48 121

.46 117 PCT 17

.44 75 PCT 14

.94 103 PCT 25 TBP

.37 135 PCT 12

.37 91 PCT 12

.20 95 PCT

.12 56 PCT

.25 48 PCT 1.24 107 PCT

.88 123 PCT TBP

. 70

.58

.46 113 PCT 86 PCT 129 PCT TBP

.28 99 PCT

.24 68 PCT

.28 75 PCT

.32 61 PCT

.29 65 PCT

. 85 115 PCT TBP

. 51 110 PCT

. 25 117 PCT

.25 97 PCT

. 34 110 PCT 7

5 9

27 22 21 18 16 11 10 12 11 11 22 17 10 l(i) 13 P2 BW2 P2 BWl P2 BWl P2 BWl P2 09C P2 10H P2 llH P2 BWl P2 BWl P2 BW2 P2 BWl P2 BWl P2 BW2 P2 BWl P2 BWl P2 VS2 P2 VSl P2 BWl P2 VS3 P2 BW2 P2 VS3 P2 BW2 P2 09C

-. 77

-1. 07

-1.09

.89

-1.69

-1.23

-.53

-. 77

.85

-.91

-1. 05

.87

-. 90

.90

.91

-. 77

-.94

-.96

.89

-. 79

.76

-. 74

-1.57 TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 NBAZl

. 610 SBAY2

.610 SBAY2

.610

. 610

.610

. 610

.610

.610

.610

. 610

. 610

.610 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 NBAZl SBAY2 SBAY2 SBAY2 NBAZl

.610 SBAY2

. 610 SBA Y2

. 610 SBAY2

.610 SBAY2

.610

.610

.610

. 610

.610

. 610

. 610 SBAY2 SBAY2 NBAZl SBAY2 SBAY2 SBAY2 SBAY2 12 H

5 H

6 H

40 H

3 H

3 H

9 H

22 H

22 H

5 H

5 H

40 H

6 6

6 40 H

H H

H 6

H 10 H

10 H

11 H

5 H

5 H

40 H

6 H

6 H

6 H

4 H

198 7

21 10 122 122 156 106 106 6

6 7

22 22 22 9

8 124 143 199 5

5 6

23 7

7 114

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

20 ST Max

01 CXl 01 SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

37 122 39 122 41 122 165 122 167 122 32 123 34 123 34 123 36 123 38 123 40 123 48 123 58 123 108 123 152 123 162 123 166 123 31 124 35 35 35 39 41 124 124 124 124 124 113 124

.47 120 PCT 15

.23 141 PCT 10

.33 129 PCT 13

.46 93 PCT 18

.33 61 PCT 14

.40 102 PCT 14

.76 124 PCT 20 TBP

.43 60 PCT

.24 57 PCT

.25 66 PCT

.47 77 PCT

.29 98 PCT

.20 127 PCT

.22 127 PCT

.21 137 PCT

.43 42 PCT

.61 126 PCT

. 78

.40

.31

.32 89 PCT 137 PCT TBP 39 PCT 105 PCT

.21 106 PCT 14 10 10 17 10 10 17 19 21 13 13 11 P2 BW2 P2 VS3 P2 BW2 P2 BW2 P2 BW2 P2 VS3 P2 BW2 P2 BWl P2 BWl P2 BWl P2 09C P2 BWl P2 BW2 P2 VSl P2 VS5 P2 BW2 P2 BWl P2 BWl P2 BWl P2 BWl P2 vs3*

P2 VS2

-.95

.78

-. 75

.98 1.00

-.65

-. 78 1.07

-1. 17

.95

-1.64

-. 76

-1. 70

.70

.85

.86

.85

-. 94

-. 28

-. 96

.75

.84 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH

.6J,_0 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610

.610

.610 SBAY2 SBAY2 NBAZl SBAY2 SBAY2

.610 SBAYl 3

H 150 6

H 24 6

H 12 H

12 H

6 H

5 H

235 c 3

H 6

H 6

H 4

H 6

165 164 40 21 9

149 25 5

104 3

H 87 12 H

45 12 H

155 12 H

160 12 H

162 6

H 39 3

3 40 4

3 H

H H

H H

23 H

i48 148 5

130 135 116

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

21 ST Max

SG - 11 Calls of Interest Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+~----+----+---------+------~--+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS OEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

165 124 167 124 128 125 164 125 166 125 25 126 51 126 51 126 75 126 79 126 111 126 131 126 145 126 149 126 165 126 24 127 28 127 88 127 108 127 124 127 146 127 152 127 1.10 106 PCT 26

.40 107 PCT 13

.30 90 PCT 12 1.22 124 PCT 27

.90 116 PCT 23

.31 100 PCT 11

.26 70 PCT

.22 94 PCT

.22 45 PCT

.42 99 PCT

.23 108 PCT

.30 57 PCT 11 10 11 17 11 10

.53 120 PCT 19

.30 74 PCT 13 1.05 105 PCT 28

.48 139 PCT 14

.26 53 PCT 10

.26 107 PCT 12

.21 111 PCT 10

.40 98 PCT 16

.22 59 PCT 10

.24 72 PCT 11 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BWl P2 09H P2 VS3 P2 BWl P2 BWl P2 BW2 P2 BW2 P2 VS3 P2 VSl P2 BW2 P2 BWl P2 BWl P2 BWl P2 BW2 P2 BW2 P2 VSl P2 BW2

-.68

-.64

-.80

.86

-. 85

.93

. 70

'.74

.68

.83

.81

.72

-.89

.74

-. 87

1. 08

.86

-.80 2.28

-. 81

.81

-.72 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

. 610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 11 H

11 H

23 H

11 H

11 H

5 H

4 H

4 H

12 H

12 i-t 12 H

22 H

156 155 130 153 154 29 92 92 66 64 48 147 12 H

141 12 H

139 12 H

128 24 c 69 6

H 36 12 H

86 12 H

96 12 H

105 12 H

116 12 H

119

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+--~----+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

22 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

156 127 158 127 160 127 162 127 39 128 49 128 127 128 141 128 163 128 165 128 165 128 90 129 132 129 152 129 162 129 13 130 41 130 111 130 129 130 129 130 159 130 161 130 163 130

.24 57 PCT 11

.23 81 PCT 11

.60 64 PCT 20

.67 80 PCT 22

.43 48 PCT 14

.30 133 PCT 12

.28 125 PCT 12

.30 49 PCT 11

.80 96 PCT 21

.38 99 PCT 15

.55 78 PCT 20

.27 84 PCT 10

.20 74 PCT 8

.33 42 PCT 12

.60 106 PCT 18

.27 130 PCT 10

.28 90 PCT 12

.37 98 PCT 11

.31 82 PCT 10

.44 81 PCT 13

.42 135 PCT 13

.62 125 PCT 17

.62 133 PCT 17 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BWl P2 08H P2 BW2 P2 BW2 P2 BW2 P2 BWl P2 BW2 P2 10H P2 VS!

P2 BW2 P2 BW2 P2 BWl P2 VS3 P2 BWl P2 VS2 P2 VS2 P2 BW2 P2 BW2 P2 BW2

-. 75

-. 83

-. 74

-. 78

.80

.69

.83

1. 06

.91

-. 94

-.84

-1.00

.69

-. 82

.87

.90

.84

.91

-.68

.75

.76

.82

.84 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 12 H

121 12 H

122 12 H

123 12 H

124 3

H 113 4

H 94 23 H

140 11 H

135 11 H

124 12 H

12 H

11 H

11 H

127 127 82 104 11 H

114 11 H

119 23 c 46 4

H 97 6 c 253 2 c 18 2 c 18 2 c 33 2 c 34 2 c 35

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

23 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 8EGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

165 130

.57 113 PCT 16 P2 BW2

.85 TEH TEC

.610 SBAY2 2 c 36 88 131

.24 127 PCT 10 P2 BWl

-. 76 TEH TEC

.610 SBAY2 7 c 38 90 131

.11 102 PCT 5

P2 10H

-. 99 TEH TEC

.610 SBAY2 5 c 225 156 131

.38 93 PCT 12 P2 BW2

-. 79 TEH TEC

.610 SBAY2 2 c 41 158 131

.35 130 PCT 11 P2 BW2

. 77 TEH TEC

.610 SBAY2 2 c 40 162 131

.74 50 PCT 19 P2 BW2

.85 TEH TEC

.610 SBAY2 2 c 38 164 131 1.23 105 PCT 26 P2 BW2

.89 TEH TEC

.610 SBAY2 2 c 37 35 132

.33 114 PCT 12 P2 VS3

.56 TEH TEC

.610 SBAY2 9 c 106 87 132

.30 53 PCT 11 P2 BWl

1. 00 TEH TEC

.610 SBAY2 8 c 8

97 132

.39 90 PCT 14 P2 BWl

-. 80 TEH TEC

.610 SBAY2 5 c 204 143 132

.36 127 PCT 13 P2 VS4

-. 78 TEH TEC

.610 SBAY2 1 c 23 163 132

.29 61 PCT 11 P2 BW2

.80 TEH TEC

.610 SBAY2 1 c 33 98 133

.30 133 PCT 10 P2 BWl

1. 05 TEH TEC

.610 SBAY2 6 c 235 118 133

.43 111 PCT 13 P2 BWl

-. 77 TEH TEC

.610 SBAY2 6 c 260 126 133

.18 96 PCT 8

P2 VS2

1. 23 TEH TEC

.610 SBAY2 1 c 52 136 133

.12 90 PCT 5

P2 VSl

.95 TEH TEC

.610 SBAY2 1 c 47 154 133

.25 148 PCT 10 P2 BW2

-. 87 TEH TEC

.610 SBAY2 1 c 38 103 134

.32 102 PCT 10 P2 BWl

.99 TEH TEC

.610 SBAY2 6 c 222 119 134

.32 72 PCT 11 P2 BWl 1.19 TEH TEC

.610 SBAY2 8 c 7

90 135

.24 74 PCT 10 P2 10H

-.99 TEH TEC

.610 SBAY2 5 c 200 104 135

.40 78 PCT 14 P2 VS2

.85 TEH TEC

.610 SBAY2 5 c 193 12 137

.17 84 PCT 7

P2 05H

.13 TEH TEC

.610 SBAYl 23 c 37

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

24 ST Max

w

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

62 137 90 137 122 137 130 137 154 137 122 139 140 139 101 140 125 140 125 140 159 140 152 141 158 141 41 142 101 142 46 143 104 143 134 143 119 144 139 144 141 144 153 144 44 145

.28 118 PCT 10

.32 97 PCT 10

.48 72 PCT 14

.29 97 PCT 11

.38 116 PCT 14

.42 83 PCT 13

.34 113 PCT 11

.24 104 PCT 10

.26 120 PCT 10

.26 88 PCT 10

.24 105 PCT 10

.24 61 PCT 10

.48 123 PCT 16

.33 50 PCT 10

.32 66 PCT 10

.24 143 PCT 10

.33 127 PCT 12

.31 63 PCT 10

.26 53 PCT 10

.28 57 PCT 11

.54 117 PCT 17

.24 127 PCT 10

.34 142 PCT 10 P2 VS3 P2 10H P2 VSl P2 VSl P2 BW2 P2 VSl P2 BWl P2 BWl P2 VSl P2 VS2 P2 BW2 P2 BW2 P2 BW2 P2 BWl P2 VS2 P2 BWl P2 BWl P2 BW2 P2 BW2 P2 VSl P2 VS3 P2 BW2 P2 VS3

-. 73

-.65

.89

. 77

-. 91

.87

-. 78 1.10

-.68

-. 78

.90

-.82

-. 80

-. 97

.84

.74

-. 76

-. 87

.87

-. 78

-.95

.97

-. 74 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 61© SBA Y2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 8 c 55 6 c 213 6 c 195 1 c 89 1 c 77 2 c 141 2 c 132 5 c 128 1 c 94 1

c 94 1 c 111 1 c 115 1 c 112 10 c 215 6 c 135 9 c 201 5 c 105 2 c 172 5 c 95 1 c 138 1 c 139 1 c 145 10 c 233

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

25 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1Rl9 PVNGSl 20160401 04/25/2016 08:22:19

-+* - - - - + - - - - + - - - - - - - - - + - - - - + - - - - + - - - - + - - - - - - - + - - - - - + - - - - + - - - - - - - - - + - - - - - - - - - + - - - - + - - - - + - - - - - - + - - - - - - + - - - - - - + - - + - - - - - + - - - - - - - - - + - - - - - - - - - +

J ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

84 145

.33 91 PCT 10 P2 VS3

.84 TEH TEC

.610 SBAY2 6 c 118 106 145

.33 88 PCT 10 P2 BWl

-1. 35 TEH TEC

.610 SBAY2 6 c 105 77 146

.25 59 PCT 10 P2 BWl

.93 TEH TEC

.610 SBAY2 7 c 106 105 146

.32 93 PCT 10 P2 VS2

.81 TEH TEC

.610 SBAY2 6 c 90 123 146

.36 46 PCT 11 P2 VS3

-.84 TEH TEC

.610 SBAY2 2 c 180 76 147

.26 56 PCT 10 P2 VS2

.80 TEH TEC

.610 SBAY2 7 c 122 86 147

.37 108 PCT 13 P2 VS2

.73 TEH TEC

. 610 SBAY2 5 c 72 104 147

.32 124 PCT 12 P2 BWl

-. 23 TEH TEC

. 610 SBAY2 5 c 64 114 147

.32 51 PCT 12 P2 BW2

-. 90 TEH TEC

. 610 SBAY2 5 c 59 126 147

.67 118 PCT 20 P2 VS2 1.19 TEH TEC

.610 SBAY2 1 c 6

45 148

.31 41 PCT 12 P2 BWl

.90 TEH TEC

.610 SBAY2 9 c 267 75 148

.27 50 PCT 10 P2 BWl

.85 TEH TEC

.610 SBAY2 8 c 114 99 148

.35 142 PCT 12 P2 BWl

-. 80 TEH TEC

.610 SBAY2 5 c 44 101 148

.45 97 PCT 15 P2 BWl

-. 75 TEH TEC

.610 SBAY2 5 c 45 103 148

.25 150 PCT 10 P2 BWl

-. 71 TEH TEC

. 610 SBAY2 5 c 46 109 148

.34 86 PCT 12 P2 BWl

-1.96 TEH TEC

.610 SBAY2 5 c 49 115 148

.56 82 PCT 17 P2 VS3

-.75 TEH TEC

.610 SBAY2 5 c 52 139 148

.36 81 PCT 13 P2 VSl

.82 TEH TEC

.610 SBAY2 1 c 163 141 148

.55 114 PCT 17 P2 VS3

-. 76 TEH TEC

.610 SBAY2 1 c 164 58 149

.43 143 PCT 14 P2 BWl

.71 TEH TEC

.610 SBAY2 8 c 123 62 149

.34 82 PCT 12 P2 VS3

-.86 TEH TEC

.610 SBAY2 8 c 127 68 149

.27 98 PCT 10 P2 BWl

-.98 TEH TEC

.610 SBAY2 8 c 130

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UT! L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

26 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 2016(1)4(1)1 (1)4/25/2(1)16 (1)8:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

84 149

.58 122 PCT 16 P2 VS2

.77 TEH TEC

.61(1)

SBAY2 6 c 71 14(1) 149

.24 51 PCT 10 P2 BWl

-. 85 TEH TEC

.61(1)

SBAY2 1 c 176 59 15(1)

.36 63 PCT 12 P2 VS2

-1.1(1)

TEH TEC

.61(1)

SBAY2 12 c 14 1(1)1 15(1)

.93 1(1)(1)

PCT 22 P2 VS3

-. 93 TEH TEC

.61(1)

SBAY2 6 c 38 1(1)9 15(1)

.25 55 PCT 8

P2 VS3

-.76 TEH TEC

. 61(1). SBAY2 6 c 42 7(1) 151

.26 112 PCT P2 VS2

.75 TEH TEC

.61(1)

SBAY2 7 c 138 84 151

. 33 111 PCT 12 P2 VS2

.72 TEH TEC

.61(1)

SBAY2 7 c 145 1(1)2 151

.33 76 PCT 1(1)

P2 VS2

.8(1)

TEH TEC

.61(1)

SBAY2 4 c 39 148 151

. 36 118 PCT 11 P2 llH

.87 TEH TEC

.61(1)

SBAY2 4 c 17 35 152

.28 66 PCT 11 P2 BWl

1. (1)2 TEH TEC'

.61(1)

SBAY2 11 c 7(1) 79 152

.28 69 PCT 1(1)

P2 VS2

-. 7(1)

TEH TEC

.61(1)

SBAY2 8 c 139 117 152

.46 62 PCT 13 P2 VS3

.99 TEH TEC

.610 SBAY2 4 c 56 135 152

.29 51 PCT 11 P2 VS4

-. 8(1)

TEH TEC

.610 SBAY2 3 c 6

137 152

.54 7(1)

PCT 17 P2 VS4

-.93 TEH TEC

.61(1)

SBAY2 3 c 7

132 153

.36 134 PCT 13 P2 llH

-1. 72 TEH TEC

.61(1)

SBAY2 3 c 28 79 154

.25 56 PCT 1(1)

P2 BWl 1.14 TEH TEC

.61(1)

SBAY2 7 c 162 125 154

.34 68 PCT 13 P2 VS3

-.89 TEH TEC

.61(1)

SBAY2 3 c 58 68 155

.26 102 PCT 10 P2 BWl

-.92 TEH TEC

.61(1)

SBAY2 7 c 176 9(1) 155

.19 94 PCT 7

P2 l(l)H

-. 38 TEH TEC

.61(1)

SBAY2 7 c 187 1(1)4 155

.33 115 PCT 10 P2 BWl

.48 TEH TEC

.61(1)

SBAY2 4 c 79 79 156

.27 118 PCT 10 P2 09C

.42 TEH TEC

.61(1)

SBAY2 8

c 184 135 156

.46 1(1)3 PCT - 13 P2 VS2

-. 36 TEH TEC

.61(1)

SBAY2 4 c 1(1)2

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+-----C---+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

27 ST Max

CX>

en SG - 11 Calls of Interest Palo Verde 1 U1Rl9 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

33 1'58 75 158 109 158 109 158 119 158 84 159 88 159 86 161 92 161 106 161 108 161 111 162 117 162 76 163 84 163 122 163 79 164 115 164 129 164 129 164 100 165 132 165 132 165

.29 31 PCT 10

.32 66 PCT 12

.28 134 PCT 11

.49 121 PCT 16

.23 78 PCT 10

.32 100 PCT 12

.28 66 PCT 11

.37 131 PCT 12

.28 81 PCT 10

.39 122 PCT 14

.28 125 PCT 11

.29 86 PCT 11

.30 88 PCT 12

.30 115 PCT 11

.36 126 PCT 13

.31 96 PCT 10

.33 142 OSI

.36 49 PCT 11

.48 76 PCT 14

.32 50 PCT 10

.32 55 PCT 12

.66 127 PCT 19

.26 59 PCT 10 P2 BWl P2 VS2 P2 BWl P2 VS4 P2 BWl P2 VS2 P2 VS2 P2 VS2 P2 VS2 P2 BW2 P2 BW2 P2 BWl P2 BWl P2 VS2 P2 VS2 P2 VS4 Pl 09C P2 BW2 P2. VSl P2 BW2 P2 VS2 P2 llH P2 BWl 1.09

-.84

-. 81

-.88

.81

.75

.85

.77

.71

-1.42

-1. 85

.97

.80

. 78

.87

-. 72

.90

.86

.89

.84

.92

.78

-. 60 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 12 c 129 7 c 202 3 c 3 c 96 96 3 c 101 7 c 222 7 c 224 8 c 259 8 c 262 3 c 129 3 c 128 3 c 138 3 c 141 9 c 27 9 c 31 4 c 160 10 c 9

4 c 182 4 c 189 4 c 189 3 c 172 3 c 156 3 c 156

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

28 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

134 165

.27 38 PCT 11 P2 VS3

.93 TEH TEC

.610 SBAY2 3 c 152 113 166

.26 43 PCT 10 P2 VSl

-. 82 TEH TEC

.610 SBAY2 3 c 180 101 168

.45 49 PCT 13 P2 VS3

-1.04 TEH TEC

.610 SBAY2 4 c 211 127 168

.32 141 PCT 10 P2 BWl

.96 TEH TEC

.610 SBAY2 4 c 224 120 169

.30 136 PCT 12 P2 BW2

-1.06 TEH TEC

.610 SBAY2 3 c 194 29 170

.35 74 PCT 13 P2 VS3

.88 TEH TEC

.610 SBAYl 15 c 92 113 170

.24 107 PCT 10 P2 BW2

1. 02 TEH TEC

.610 SBAY2 3 c 212 117 170

.26 62 PCT 10 P2 BWl

.86 TEH TEC

.610 SBAY2 3 c 214 119 170

.27 48 PCT 11 P2 VS2

-.60 TEH TEC

.610 SBAY2 3 c 215 121 170

.26 60 PCT 10 P2 VS2

.71 TEH TEC

.610 SBAY2 3 c 216 125 170

.28 76 PCT 11 P2 BWl

.72 TEH TEC

.610 SBAY2 3 c 218 116 171

.31 107 PCT 10 P2 BWl

.99 TEH TEC

.610 SBAY2 4 c 229 69 172

.74 65 NOi Pl VS4

-.36 TEH TEC

.610 SBAY2 14 c 54 71 172

.50 120 PCT 14 P2 VS3

-.98 TEH TEC

.610 SBAY2 14 c 55 123 172

.21 150 PCT 9

P2 VS3

-1.18 TEH TEC

.610 SBAY2 3 c 222 122 173

.28 67 PCT 11 P2 VS4

-. 75 TEH TEC

.610 SBAY2 3 c 223 84 175

.37 140 PCT 11 P2 VS2

. 72 TEH TEC

.610 SBAY2 14 c 64 82 177

.26 111 PCT 10 P2 09C

.88 TEH TEC

.610 SBAY2 13 c 67 106 177

.28 36 PCT 11 P2 BW2

-. 85 TEH TEC

.610 SBAY2 3 c. 250 108 177

.24 51 PCT 10 P2 BW2

-.88 TEH TEC

.610 SBAY2 3 c 251 112 177

.32 83 PCT 12 P2 BW2

-.84 TEH TEC

.610 SBAY2 5 c 6

49 178

.21 83 PCT 8

P2 BWl

-. 73 TEH TEC

.610 SBAY2 13 c 85

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UT Ill UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

29 ST Max

SG - 11 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

48 179 104 179 79 180 85 180 87 180 87 180 89 180 91 180 95 180 56 181 8

183 83 184 10 185 90 185 94 185 85 188

.17 116 PCT 7

.28 107 PCT 9

.25 81 PCT 10

.27 116 PCT 10

.77 122 PCT 21

.28 124 PCT 10

.31 115 PCT 11

.25 139 PCT 10

.26 131 PCT 10

.32 136 PCT 10

.24 94 PCT 10

.31 81 PCT 11

.24 141 PCT 10

.31 138 PCT 10

.32 97 PCT 10

.27 100 PCT 12 P2 09C P2 BW2 P2 VS4 P2 BWl P2 BWl P2 09C P2 BWl P2 BWl P2 BWl P2 VS3 P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 09C

-1.25

-. 94

-.44

.88

.97

.86

.23

1. 07

-1. 01

-1.09

.99 1.00

-.94

-.97

-.66

.66 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl

. 610 SBAYl

.610 SBAYl

.610 SBAYl

.610 SBAYl 13 c 134 6 c 23 23 c 139 23 c 142 23 c 143 23 c

143 23 c 144 23 c 145 23 c 147 24 c

  • 92 19 c 125 23 c 103 19 c 117 24 c 140 24 c 138 25 c 32

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

30 Tubes: 610 Records: 697 ST Max

APPENDIXC STEAM GENERATOR 12

SUMMARY

DATA SHEETS 45 of 85

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

22 5

61 10 55 12 92 17 98 19 51 22 107 24 41 26 118 31 124 33 111 34 61 38 65 38 77 38 99 38 125 38 62 39 86 39 102 39 119 40 125 40 125 40 135 40

.24 103 PCT 10

.25 37 PCT 10

.49 92 PCT 14

.47 110 PCT 16

.35 151 NQI

.27 125 PCT 10

.25 34 PCT 10

.27 49 PCT 10

.30 57 PCT 11

.91 117 PCT 23

.25 32 PCT 9

.25 128 PCT 10

.32 83 PCT 12

.26 145 PCT 11

.26 141 PCT 11

.42 44 PCT 12

.32 129 PCT 12

.30 123 PCT 12

.28 147 PCT 11

.56 76 PCT 15

.86 110 PCT 20 1.30 123 PCT 26

.32 47 PCT 11 P2 BWl P2 VS3 P2 BW2 P2 VS3 3

TSH P2 VS3 P2 VS2 P2 VS3 P2 BWl P2 10H P2 BW2 P2 *09C P2 BWl P2 VS4 P2 BW2 P2 VS2 P2 VS3 P2 VS2 P2 VS2 P2 VS2 P2 VS2 P2 VS2 P2 VS3

.85

-. 76

-1.32

-1.05

.84

1. 24

-. 70

1. 00

-1.93

.00

-. 75

.69

.98

-. 62

.81

.70

.88

-. 67

-. 73

-. 77

-. 91

-.58

-.88 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

. 610 SBAYl

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2 224 c 93 201 c 204 226 c 7

201 c 124 201 c 115 228 c 16 201 c 69 228 c 30 203 c 23 203 c 27 203 c 165 205 c 5

205 c 7

205 c 13 205 c 24 204 c 59 205 c 61 205 c 49 205 c 41 206 c 192 206 c 195 206 c 195 203 c 36

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

1 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

101 117 117 32 92 94 102 122 122 122 41 42 42 42 43 43 43 43 43 43 43 128 43 130 43 75 44 85 44 123 44 139 44 120 45 124 45 81 46 72 47 110 47 122 47

.31

.35

.43

.28

.21

.28

.31

.35

.29

.66

.43 57 PCT 51 PCT 118 PCT 139 PCT 126 PCT 123 PCT 116 PCT 122 PCT 153 PCT 129 PCT 117 PCT

.34 127 PCT

.49 143 PCT 11 13 15 11 7

11 12 13 11 20 15 13 17

.87 78 PCT 21

.28 93 PCT 9

.39 79 PCT 12

.28 38 PCT 10

.46 80 PCT 14

.69 94 PCT 18

.26 146 PCT 11

.28 127 PCT 11

.33 143 PCT 13

.49 136 PCT 17 P2 BW2 P2 BWl P2 VS2 P2 VS4 P2 VS3 P2 BWl P2 BWl P2 BWl P2 VSl P2 VS2 P2 VS3 P2 VSl P2 BW2 P2 VS3 P2 VS2 P2 VS2 P2 BWl P2 VS4 P2 VS2 P2 VS2 P2 VS3 P2 BWl P2 VS3

-. 86

.93

-.84

-. 87

-.84

-. 94

-. 63

-. 81

.53

.90

.94

-. 85

-. 77

-. 71

. 70

.78

.92

-.87

.87

-. 73

-.89

-. 76

-. 64 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610

.610

.610

.610

. 610

. 610

.610

. 610

.610

.610

.610 SBAY2 SBAY2 SBAY2 SBAY2 SBAYl SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 216 c 205 c 205 c 205 c 229 c 205 c 205 c 205 c 205 c 205 c 205 c 205 c 205 c 99 83 90 90 149 103 102 98 194 194 194 191 190 206 c 76 206 c 81 206 c 205 203 c 40 206 c 216 206 c 214 205 c 130 205 c 172 205 c 153 205 c 211

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

2 ST Max

SG - 12 Calls of Interest Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

51 48 131 48 130 49 130 49 146 49 115 50 137 50 105 52 143 52 38 53 124 53 124 53 128 53 128 53 115 54 127 54 127 54 145 54 114 55 114 55 116 55 130 55 101 56 113 56 78 57

.28 58 PCT 12

.37 95 PCT 12

.73 91 PCT 18 1.11 106 PCT 24

.35 56 PCT 12

.30 92 PCT 10

.36 57 PCT 12

.33 48 PCT 12

.28 61 PCT 9

.26 19 PCT 10

.31 63 PCT 11

.38 66 PCT 13

.70 95 PCT 19

.93 121 PCT 23

.57 70 PCT 15

.56 97 PCT 15

.32 80 PCT 10

.27 93 PCT 9

.34 74 PCT 11

.48 120 PCT 14

.37 80 PCT 11

.32 40 PCT 10

.30 37 PCT 12

.40 49 PCT 14

.32 44 PCT 12 P2 VS3 P2 VS2 P2 VSl P2 VS3 P2 BWl P2 VS3 P2 VSl P2 VS2 P2 VS3 P2 VS3 P2 VSl P2 VS2 P2 VSl P2 VS3 P2 VS2 P2 VS3 P2 VS4 P2 VS2 P2 VS2 P2 VS3 P2 VS2 P2 VS2 P2 BWl P2 VS2 P2 VS2

.89

-.65

-. 68

-.67

.85

-. 71

-.88

-. 78

.62

-. 76

-. 83

.89

-. 87

.79

-. 78

.93

-.84

.13

-. 71

-.88

-.72

-. 76

1. 08

-. 74

-.71 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2 235 c 8

206 c 226 206 c 232 206 c 232 203 c 63 208 c 237 207 c 10 211 c 46 204 c 112 213 c 86 207 c 202 207 c 202 207 c 204 207 c 204 208 c 216 208 c 210 208 c 210 204 c 110 208 c 194 208 c 194 208 c 195 208 c 204 209 c 269 209 c 275 209 c 240 I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

. I I

I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTIL21

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

3 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

118 57 92 59 118 59 125 60 135 60 135 60 48 61 60 61 45 62 147 62 147 62 120 63 150 63 85 64 136 65 146 65 39 66 47 66 147 66 159 66 120 67 9

68 113 68

.41 125 PCT 14

.41 41 PCT 12

.41 105 PCT 12

.36 78 PCT 12

.26 104 PCT 10

.40 98 PCT 14 1.15 105 PCT 27

.33 85 PCT 13

.33 93 PCT 11

.35 100 PCT 12

.97 107 PCT 24

.80 73 PCT 19 1.10 97 PCT 25

.24 36 PCT 10

.43 77 PCT 14

.32 60 PCT 10

.28 93 PCT 10

.43 95 PCT 13

.40 53 PCT 12

.27 136 PCT 10

.52 65 PCT 15

.26 65 PCT 11

.24 40 PCT 10 P2 VS2 P2 BWl P2 BW2 P2 VS4 P2 VS3 P2 VS3 P2 09C P2 BWl P2 BWl P2 VS2 P2 VS3 P2 VS2 P2 VSl P2 VS2 P2 VS3 P2 VS3 P2 08C P2 VS3 P2 VS3 P2 BW2 P2 VS2 P2 BW2 P2 BWl

.94

-.68

.32

.68

-.94

.62

-1. 47

-. 74

-. 68

.78

-. 83

-. 76

.88

-. 73

.73

.95

.74

-. 69

-.94

.75

-. 69 1.24

.72 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 207 c 177 210 c 184 208 c 169 207 c 169 207 c 164 207 c 164 213 c 12 209 c 195 212 c 152 207 c 207 c 208 c 36 36 139 207 c 23 209 c 154 207 c 128 208 c 43 212 c 112 212 c 116 208 c 42 203 c 82 208 c 104 215 c 30 209 c 112

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

4 ST Max

Cl1 0

0 -

CXl Cl1 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

147 68

.20 56 PCT 8

P2 VS3

-. 83 TEH TEC

.610 SBAY2 207. c 100 159 68

.36 102 PCT 12 P2 BW2

.75 TEH TEC

.610 SBAY2 203 c 93 36 69

.28 65 PCT 10 P2 VS3

-.73 TEH TEC

.610 SBAY2 211 c 97 118 69

.61 90 PCT 18 P2 VS3

.88 TEH TEC

.610 SBAY2 207 c 85 122 69

.31 59 PCT 11 P2 BWl

-. 82 TEH TEC

.610 SBAY2 207 c 86 138 69

.26 55 PCT 10 P2 VSl

.83 TEH TEC

.610 SBAY2 207 c 94 140 69

.33 61 PCT 12 P2 VSl

-. 69 TEH TEC

.610 SBAY2 207 c 95 41 70

.10 150 NQI 3

BWl 11.02 TEH TEC

. 610 SBAY2 212 c 78 127 70

.39 47 PCT 12 P2 VSl

-. 85 TEH TEC

.610 SBAY2 208 c 92 6

71

.67 22 NQI 3

TSH 10.69 TEH TEC

.610 SBAY2 216 c 8

44 71

.35 32 PCT 11 P2 VS3

.92 TEH TEC

.610 SBAY2 212 c 58 46 71

.36 95 PCT 12 P2 VS3 1.00 TEH TEC

.610 SBAY2 212 c 57 140 71 1.49 113 PCT 28 P2 VS2

-. 92 TEH TEC

.610 SBAY2 208 c 75 154 71

.26 31 PCT 9

P2 VS3

.96 TEH TEC

.610 SBAY2 208 c 32 162 71

.28 61 PCT 10 P2 BWl

-. 75 TEH TEC

.610 SBAY2 203 c 88 113 72

.25 61 PCT 10 P2 BWl

-. 81 TEH TEC

.610 SBAY2 209 c 56 123 72

.41 64 PCT 14 P2 VS3

-. 73 TEH TEC

.610 SBAY2 207 c 78 163 72

.28 88 PCT 10 P2 BW2

-. 75 TEH TEC

.610 SBAY2 203 c 89 30 73

.27 30 PCT 10 P2 08C

.57 TEH TEC

.610 SBAY2 211 c 66 40 73

.36 40 PCT 13 P2 08C

.83 TEH TEC

.610 SBAY2 211 c 61 46 73

.55 80 PCT 17 P2 08H

.45 TEH TEC

.610 SBAY2 211 c 58 104 73

.78 87 PCT 22 P2 VS3

.97 TEH TEC

.610 SBAY2 209 c 9

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

5 ST Max

Q, CXl

()'I SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

140 73 156 73 160 73 119 74 129 74 156 75 156 75 160 75 162 75 162 75 164 75 137 76 159 76 161 76 24 77 30 77 46 77 48 77 90 77 114 77 130 77 27 78 41 78

.35 61 PCT 12

.39 116 PCT 12

. 71 113 PCT

.42 24 PCT

.45 37 PCT

.82 73 PCT

.33 135 PCT

.34 36 PCT

.37 151 PCT

.35 151 PCT

. 53 116 PCT

.49 135 PCT

.29 41 PCT

.20 91 PCT

.40 67 PCT

.27 114 PCT

.50 125 PCT

.28 71 PCT

.29 56 PCT

.30 134 PCT

.36 119 PCT

.64 53 PCT

.31 141 PCT 18 13 13 19 10 10 11 10 14 15 10 7

12 9

13 9

10 10 11 17 10 P2 VSl P2 VS2 P2 BW2 P2 VS3 P2 VSl P2 VSl P2 VS2 P2 VS3 P2 BWl P2 VS4 P2 BW2 P2 VS3 P2 BW2 P2 BWl P2 08C P2 08C P2 BWl P2 09C P2 BWl P2 VS2 P2 VS3 P2 BWl P2 BW2

-.86

-. 62

.75

-.84

-. 82

.92

.79

.86

-. 89

. 78

-. 83

-1.13

.72

-. 90

-. 91

.92

.86

-1. 73

-.90

-. 78

.76

-1.03

-.83 TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 207 c 208 c 204 c 15 H

15 H

9 H

9 H

9 H

9 H

9 H

9 H

10 H

10 H

10 H

1 H

2 H

5 H

5 H

24 H 16 H

16 H

1 H

3 H

58 34 91 45 40 48 48 50 51 51 52 33 22 21 6

13 11 45 23 82 90 10 47

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

6 ST Max

c.n S,

O>

c.n SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

47 78 30 79 30 79 40 79 46 79 76 79 88 79 116 79 31 80 33 80 35 80 35 80 41 41 80 80 43 80 49 80 105 80 163 80 34 81 58 81 162 81 164 81 168 81

.72 125 PCT

.34 153 PCT

.30 59 PCT

.30 46 PCT

. 38 113 PCT

.45 107 PCT

.40 141 PCT

.24 52 PCT

.64 146 PCT

.40 131 PCT

.35 30 PCT

.35 41 PCT 17 11 10 12 13 12 8

17 12 11 11

.99 108 PCT 21 TBP

.46 47 PCT 13

.33 81 PCT

.30 113 PCT 10

.32 90 PCT 11

.24 88 PCT 8

.49 49 PCT 13

.28 44 PCT 10

.28 144 PCT 10

.39 99 PCT 13 P2 BWl P2 BWl P2 BW2 P2 BW2 P2 BWl P2 VS3 P2 BWl P2 VS2 P2 BW2 P2 BWl P2 BWl P2 BW2 P2 BW2 P2 BW2 P2 08H P2 VS3 P2 BW2 P2 08C P2 BWl P2 BW2 P2 BW2 P2 BW2

.81

-. 36

-.88

-.68

-.98

-. 81

-.92

-.85

-.88

.83 1.02

-.91

-.83

-. 82

.81

-. 95

.89

.86

1. 02

.92

.87

-.85 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

. 610 SBA Y2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBA Y2

. 610 SBA Y2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2 5

H 1

H 1

H 3

H 4

H 23 H

23 H

15 H

1 H

2 H

2 H

2 H

3 H

234 c 3

H 5

H 12 13 13 38 54 60 54 109 14 97 22 22 37 27 59 14 16 H

104 10 H

56 2

H 98 5

H 56 10 H

87 10 H

88 10 H

90

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

7 ST Max

CXl CJ'1 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

35 82 75 82 87 82 48 83 52 83 168 83 47 84 47 84 49 84 121 84 163 84 48 85 116 85 132 85 47 47 47 47 86 86 86 86 57 86 117 86 119 86 161 86 90 87 118 87

.50 99 PCT 14

.67 125 PCT 17

.33 95 PCT 10

.76 122 PCT 19

.43 110 PCT 12

.38 105 PCT 11

.91 62 PCT 20 TBP

.51 135 PCT 14

.28 115 PCT

.46 131 PCT

.29 120 PCT

.34 139 PCT

.11 147 PCT

.85

.43 1.44 117 PCT 151 PCT 110 PCT TBP

.26 89 PCT

.33 79 PCT

.38 146 PCT

.33 38 PCT

.22 64 PCT

.78 120 PCT 9

14 9

11 5

20 13 26 8

10 12 10 7

19 P2 BWl P2 VS2 P2 BWl P2 09C P2 BWl P2 BW2 P2 BW2 P2 08H P2 VS3 P2 VS5 P2 09C P2 BWl P2 UH P2 VS3 P2 BW2 P2 BW2 P2 VS3 P2 BWl P2 BWl P2 VS2 P2 10H P2 VS3

.90

.50

-. 77

-1. 21

-. 82

-.91

.95

.81

-1.09

.85

-.82

-. 99

-.40

-1. 01

.02

1. 02 1.00

-. 70

1. 00

.56

-. 26

.82 TEC TEH VS3 TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610

.610

.610

.610 SBAY2 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 NBAZl

.610 SBAYl 2

H 23 H

23 H

4 H

5 H

9 H

3 H

234 c 4

H 16 H

10 H

3 H

20 H

10 H

3 H

3 H

3 H

234 c 5

H 19 H

19 H 9

H 23 H

19 H

99 72 78 39 17 125 64 28 38 134 94 61 19 110 31 31 31 26 36 34 33 130 112 58

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

8 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UT! L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

43 88 43 88 125 88 133 88 141 88 42 89 42 89 46 89 48 48 48 89 89 89 50 89 160 89 43 43 43 90 90 90 45 90 45 90 51 90 51 90 113 90 113 90 44 44 44 91 91 91 46 91 46 91 48 91 48 91

.83 112 PCT TBP

.76 126 PCT

.40 139 PCT

.45 119 PCT 20 19 12 13 1.11 97 PCT 23 TBP

.49 60 PCT

.57

.42

.27 79 PCT 82 PCT 66 PCT

.32 128 PCT

.50 66 PCT

.53

1. 71 88 PCT 107 PCT TBP

.36 75 PCT

.79 95 PCT

.30 148 PCT

.30 147 PCT

.56 129 PCT

.36 127 PCT 8.44

.55 85 PCT 94 PCT TBP

.62 121 PCT

.68 107 PCT

.75 107 PCT

.39 86 PCT 14 15 12 9

10 15 15 29 11 19 10 10 15 11 55 15 16 17 18 12 P2 BWl P2 VSl P2 llH P2 VSl P2 BW2 P2 BWl P2 BWl P2 VS3 P2 09C P2 VS3 P2 VSl P2 BWl P2 BW2 P2 VS3 P2 VS3 P2 BWl P2 VS3 P2 VS2 P2 VS4 P2 BWl P2 VS3 P2 VS3 P2 BW2 P2 VS3 P2 09C

-. 68

.70

-1.00

.36

-.94

-.88

-.84

-1.07

-1. 31

.89

.81 1.04

-.84

-. 98

-. 29

.91

.84

.69

.86

.82

.92

.86 1.17

.80

-1.56 TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610

.610

.610 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 2

H 234 c 20 H

30 25 30 13 H

209 13 H

205 2

H 234 c 2

H 2

H 2

H 2

H 3

H 10 H

2 H

2 H

234 c 2

H 2

H 3

H 3

H 19 H

19 H

2 H

2 H

234 c 2

H 2

H 2

H 2

H 106 24 53 73 73 73 28 140 107 107 23 32 32 27 27 73 73 108 108 22 33 33 54 54

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UT! L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

9 ST Max

C.l'I C.l'I

8.

O>

C.l'I SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

66 91 51 92 77 92 111 92 46 93 48 93 50 93 128 93 148 93 160 93 166 93 170 93 51 51 94 94 52 95 56 95 166 95 77 96 167 96 48 97 48 97 128 97 132 97

.78 109 PCT 21

.30 142 PCT 10

.65 122 PCT 17

.33 129 PCT 11

.79 91 PCT 19

.63 114 PCT 17

.31 31 PCT 10

.31 154 PCT 10

.37 32 PCT 12

.31 107 PCT 11

.29 106 PCT 10

.28 59 PCT 10 1.27 114 PCT 25 TBP

. 37 117 PCT 11

.58 143 PCT 15

.32 94 PCT 10

.26 57 PCT 9

.30 100 PCT 10 3.36 96 PCT 40 TBP

.65 109 PCT 17

.40 138 PCT 12 P2 VS3

1. 02 P2 BWl

.86 P2 VS3

-.65 P2 BWl

.79 P2 BWl

-. 82 P2 09C

-1. 61 P2 VS3

-.55 P2 VS4

-.86 P2 VS3

.80 P2 VS3

.79 P2 llH

.89 P2 BW2

-. 77 P2 BWl

-. 77 P2 VS3

-. 92 P2 VS3

-. 80 P2 BW2

-.95 P2 09H

.76 P2 BW2

.95 P2 BWl

.79 P2 VS3

-.88 P2 VSl

-.98 VS3 TEC TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH

.610 NBAZl

.610 SBAY2

.610 NBAZl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2 20 c 2

H 24 H

20 H

2 H

2 H

2 H

20 H

15 H

10 H

10 H

10 H

2 H

234 c 2

H 3

H 9

H 24 H 152 76 133 75 109 34 55 101 29 157 160 162 56 21 57 22 174 163 10 H

165 2

H 80 234 c 20 20 H

139 13 H

186

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

10 ST Max

01 Ol Q,

00 01 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

136 97 111 98 127 98 135 98 145 98 74 99 150 99 49 100 49 100 113 100 169 100 171 100 90 101 90 101 108 101 142 101 144 101 166 101 166 101 166 101 53 102 57 102 63 102 69 102

.44 135 PCT 13

.30 157 PCT 10

.52 67 PCT 14

.56 141 PCT

.59 62 PCT

.31 152 PCT

.36 136 PCT

.20 97 PCT

.31 94 PCT

.26 149 PCT

.28 110 PCT

. 31 118 PCT 1.86 105 PCT TBP

.25

.76

.34

.31

.60

.31

.55

.30

.35

.30 142 PCT 94 PCT 89 PCT 45 PCT 110 PCT 64 PCT 76 PCT 159 PCT 135 PCT 54 PCT 15 16 10 12 7

10 9

10 11 30 9

18 11 11 17 11 15 10 11 11 P2 BW2 P2 VS4 P2 BW2 P2 VS!

P2 BW2 P2 09H P2 BW2 P2 BWl P2 BWl P2 VS3 P2 BW2 P2 llH P2 VS2 P2 BWl P2 VS!

P2 VS3 P2 VS2 P2 VS3 P2 BW2 P2 VS3 P2 BW2 P2 VS3 P2 BW2

-. 77

.81

.89

-.86

.98

.68

-. 85

-1.04

.93

.78

.63

.83

-. 74

1. 77

.79

.70

-. 74

.66

-. 80

-1.08

-1.84

-1.00

-. 90 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEC

.610 SBAY2

. 610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610

.610

.610

.610

.610

.610

.610

.610

.610

.610 SBAYl SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 NBAZl 13 H

188 19 H

150 19 H

142 13 H

184 13 H

179 23 H

213 14 H 2

H 2

H 20 H

10 H

10 H

172 84 84 150 182 181 24 H

203 234 c 18 20 13 13 10 10 10 2

3 3

22 H

H H

H H

H H

H H

c 167 170 171 196 196 196 86 9

15 19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

11 ST Max

Q, O>

01 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

101 102 101 102 101 102 66 103 72 103 86 103 150 103 162 103 166 103 77 104 50 105 60 105 150 105 166 105 170 105 170 105 49 106 61 106 67 106 77 106 107 106 60 107 128 107

.45

.63 1.04

.30

.49

.36 118 PCT 104 PCT 112 PCT 114 PCT 128 PCT 121 PCT

.27 126 PCT

.32 151 PCT

.59 31 PCT

.52 129 PCT

.34 121 PCT

.32 78 PCT

.34 115 PCT

.51 129 PCT

.31 133 PCT

.42 110 PCT

.45 125 PCT

.45 131 PCT

.52 82 PCT

.80 105 PCT

.33 135 PCT

.39 32 PCT

.33 147 PCT 13 16 25 10 14 11 10 10 15 14 10 10 11 15 11 13 12 12 14 19 10 11 10 P2 VS2 P2 VS3 P2 VS4 P2 VS3 P2 VS2 P2 BWl P2 VS3 P2 VS4 P2 BW2 P2 09H P2 VS3 P2 VS2 P2 BW2 P2 BW2 P2 llH P2 VSl P2 BWl P2 VS3 P2 VS3 P2 VS3 P2 BWl P2 VS2 P2 VSl

-1.06

-.85

.97

-.59

-. 81

-. 83

.84

.87

-. 79

.97

.83

.86

-.80

-.76

.90

.84

-.94

.64

-. 85

-. 78 1.85

.97

-. 82 VS3 VS3 VS3 VS3 VS3 VS3 TEH TEH TEC TEH TEH TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH VS3 TEH

.610

.610

.610

.610

.610

.610 NBAZl NBAZl NBAZl NBAZl NBAZl NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 NBAZl 21 21 22 23 23 23 H

H c H

H H

14 H

13 13 34 273 270 229 150 9

H 207 9

H 209 24 H

223 5

H 113 3

H 12 13 H

151 10 H

214 10 H

216 10 H

216 5

H 114 5

H 163 9

H 6

9 H

11 21 H

56 5

H 162 21 H

83

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

12 ST Max

U1 co

8.

co U1 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

130 107 1.04 123 PCT 22 P2 VS2

.71 VS3 TEH

.610 NBAZl 21 H

84 168 107

.36 89 PCT 11 P2 BWl

-. 64 TEC TEH

.610 SBAY2 11 H

18 75 108

.39 126 PCT 13 P2 VS4

-. 70 TEC TEH

.610 SBAY2 10 H

10 87 108 1.09 103 PCT 24 P2 VS4

-. 93 TEC TEH

.610 SBAY2 10 H

16 115 108

.38 95 PCT 11 P2 VS2

.81 VS3 TEH

.610 NBAZl 22 H

49 171 108

.27 57 PCT 10 P2 BW2

.89 TEC TEH

.610 SBAY2 10 H

217 46 109

.46 117 PCT 12 P2 BW2

-.84 TEC TEH

.610 SBAY2 5

H 115 70 109

.34 78 PCT 10 P2 VS3

.76 TEC TEH

.610 SBAY2 7

H 104 120 109

.37 101 PCT 11 P2 VS3

1. 04 VS3 TEH

.610 NBAZl 22 H

76 126 109

.36 109 PCT 11 P2 VS3

.74 VS3 TEH

.610 NBAZl 22 H

79 152 109

.38 113 PCT 12 P2 BW2

-. 85 TEC TEH

.610 SBAY2 13 H

130 166 109

.59 121 PCT 16 P2 BW2

-. 85 TEC TEH

.610 SBAY2 12 H

16 47 110

. 34 114 PCT 10 P2 VS3

-.89 TEC TEH

.610 SBAY2 6

H 60 59 110

.49 63 PCT 13 P2 BWl

.85 TEC TEH

.610 SBAY2 5

H 170 99 110

.23 124 PCT 8

P2 VS2

.72 VS3 TEH

.610 NBAZl 21 H

101 167 110

.44 114 PCT 13 P2 VS3

.63 TEC TEH

.610 SBAY2 11 H

22 48 111

.44 135 PCT 12 P2 09C

-1.02 TEC TEH

.610 SBAY2 5

H 105 68 111

.32 56 PCT 10 P2 VS4

-. 97 TEC TEH

.610 SBAY2 8

H 170 88 111

.33 44 PCT 10 P2 BWl

-. 96 TEC TEH

.610 SBAY2 8

H 160 108 111

.67 142 PCT 17 P2 VS2

-. 92 VS3 TEH

.610 NBAZl 21 H

114 112 111

.34 133 PCT 10 P2 BWl

-1.14 VS3 TEH

.610 NBAZl 21 H

116 150 111

.34 89 PCT 11 P2 BW2

-.86 TEC TEH

.610 SBAY2 14 H

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

13 ST Max

<.n

<D SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

45 112 47 112 49 112 161 112 102 113 136 113 150 113 150 113 168 113 45 114 47 47 47 114 114 114 85 114 89 114 89 114 151 114 151 114 155 114 42 115 42 115 44 115 44 115 46 115 46 115 46 115 46 115

.81 74 PCT

.47 47 PCT

.41 131 PCT

.29 147 PCT

.32 109 PCT

.38 108 PCT

.39 149 PCT

.33 105 PCT

.28 68 PCT

. 58 113 PCT

1. 02

.45 144 PCT 142 PCT TBP

.34 99 PCT

.32 31 PCT

. 71 115 PCT

.45 142 PCT

.36 71 PCT

.36 23 PCT

.47 107 PCT

.45 56 PCT

.94

.35

.95

.37 131 PCT TBP 112 PCT 79 PCT 94 PCT TBP 18 12 11 10 10 12 12 10 10 15 21 12 10 10 17 13 11 11 13 12 20 10 20 11 P2 BW2 P2 BW2 P2 BWl P2 VS4 P2 VS4 P2 BWl P2 VSl P2 BW2 P2 BWl P2 VS3 P2 BWl P2 VS3 P2 VS2 P2 BWl P2 VS3 P2 VSl P2 BW2 P2 BW2 P2 BWl P2 BW2 P2 BW2 P2 VS3 P2 BW2 P2 BW2

.99

.98

.93

. 78

-. 73

-. 87

.82

-.86

-. 93

-. 76

.87

-.86

.76

.90

-. 71

-.82

.83

.79

-1. 01

-.90

-. 87

.86

-.91

.96 TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610

.610

.610

.610 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 6

H 62 5

H 104 5

H 123 12 H

23 23 c 152 13 H

100 13 H

107 13 H

107 12 H

5 H

5 H

5 H

234 c 8

H 8

H 8

H 13 H

13 H

11 H

6 H

6 H

5 H

234 c 5

H 5

H 5

H 234 c 34 103 124 124 16 87 85 85 88 88 45 64 64 102 14 125 125 125 15

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

14 ST Max

Ol 0

s.

co CJ1 SG - 12 Calls of Interest Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

48 115 166 115 168 115 47 116 47 116 49 116 49 116 167 116 169 116 40 117 42 117 42 117 42 117 44 117 58 117 82 117 130 117 138 117 154 117 160 117 166 117 168 117 39 118 41 118 41 118

.57 135 PCT

.47 120 PCT

.83 107 PCT

.36 54 PCT

.49 90 PCT 15 13 19 10 13 1.77 91 PCT 29 TBP

.43 123 PCT

.29 132 PCT

.45 100 PCT 2.77

.96 98 PCT 84 PCT TBP

.69 125 PCT

.45 82 PCT

.29 71 PCT

.34 131 PCT

.44 110 PCT

.42 120 PCT

.35 151 PCT

.58 128 PCT

.29 110 PCT

.69 64 PCT

.67 83 PCT

.68 131 PCT 13 10 12 35 20 16 12 9

11 13 13 11 16 10 17 16 16 P2 09C P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BWl P2 BW2 P2 VS5 P2 BWl P2 BWl P2 BWl P2 BW2 P2 VS2 P2 BWl P2 BW2 P2 BWl P2 VS3 P2 BW2 P2 VSl P2 VS3 P2 BWl P2 BWl P2 BW2

-1. 70

-. 74

-. 95

-1.40

.87

.91

.90

.67

-.91

-.96

-. 61

-. 83

.85

-.94

-. 80

-. 76

.86

-. 79

-. 81

.85

-1. 00

-. 87

-. 93 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

. 610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610 SBAY2 SBAY2 SBAY2

. 610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 NBAZl

. 610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2 6

H 11 H

11 H

6 H

6 H

101 52 53 100 100 6

H 122 234 c 17 12 H

12 H

6 H

5 H

5 H

234 c 5

H 37 36 66 100 100 13 127 5

H 202 7

H 82 23 c 179 13 H

80 12 H

.44 12 H

47 12 H

50 12 H

6 H

5 H

5 H

51 67 99 99

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

15 ST Max

8, o:>

01 SG - 12 Calls of Interest Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

43 118 43 118 43 118 45 118 53 118 89 118 119 118 139 118 141 118 143 118 38 119 40 119 40 119 42 119 42 119 88 119 90 119 94 119 104 119 144 119 37 120 37 120 37 120 39 120 39 120 4.21 107 PCT

.71 150 PCT TBP

. 65 101 PCT

.59 120 PCT

.32 103 PCT

. 30 120 PCT

.42 103 PCT

.47 55 PCT

.47 85 PCT

.37 143 PCT 3.15 84 PCT TBP 42 17 16 15 10 10 12 14 13 11 37 1.18 87 PCT 23 TBP

.18 44 PCT 6

.26 61 PCT 9

.34 40 PCT 11

.39 137 PCT 12

.27 83 PCT

.40 141 PCT 1.21 103 PCT TBP

1. 78 108 PCT TBP 10 11 24 29 P2 BWl P2 BW2 P2 BWl P2 VS3 P2 BWl P2 BWl P2 BW2 P2 BW2 P2 VSl P2 BWl P2 BWl P2 BWl P2 08H P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 BW2 P2 BWl

-. 93

-. 81 1.14

.67

-. 83

. 50

1. 00

.87

-.98

-. 90

-. 76

-. 77

. 74

-. 70

.80

-. 76

-.84

-. 81

-. 77

.94 TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEH TEC TEC TEH TEC TEH VS3 TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEH TEC

.610

.610

.610

.610

. 610 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 NBAZl

. 610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 NBAZl

. 610 NBAZl

. 610 SBAY2

.610

.610

.610

.610

.610 SBAY2 SBAY2 SBAY2 SBAY2 SBAY2 5

H 5

H 234 c 6

H 6

H 8

H 128 128 12 98 146 58 21 H

305 13 H

73 13 H

13 H

6 H

5 H

234 c 72 71 68 98 10 5

H 129 234 c 11 8

H 56 8

H 57 21 H

283 21 H

288 14 H 6

H 6

H 234 c 5

H 234 c 60 69 69 6

97 7

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UT Ill UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

16 ST Max

CJ)

I\\)

8.

CXl U'I SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

41 120 41 120 43 43 43 120 120 120 49 120 85 120 87 120 89 120 119 120 121 120 167 120 58 121 88 121 110 121 112 121 134 121 152 121 162 121 35 122 39 122 41 122 43 122 49 122 2.24 116 PCT 32 TBP 1.09

1. 56 95 PCT 101 PCT TBP

.34 51 PCT

.36 91 PCT

.36 133 PCT

.35 128 PCT

.44 133 PCT

.33 129 PCT

.32 130 PCT

.39 136 PCT

.48 66 PCT

.30 120 PCT

.17 91 PCT

.37 131 PCT

.43 141 PCT

.30 55 PCT

.36 80 PCT

. 59 77 PCT

.52 133 PCT

.30 144 PCT

.46 136 PCT 22 27 10 10 10 10 13 1f/)

11 11 13 10 6

11 13 10 10 15 14 9

13 P2 BW2 P2 BWl P2 BW2 P2 BWl P2 VS3 P2 BWl P2 BWl P2 VS3 P2 VS3 P2 BW2 P2 VS3 P2 VS4 P2 BWl P2 BWl P2 BWl P2 BW2 P2 BWl P2 BWl P2 BWl P2 BW2 P2 08C P2 BW2

-. 78

-1.00

-.88

.89

-.84

.81

.69

-. 97

-.94

.75

.75

.83

-.84

-. 76

.55

-.83

-. 86

-. 99

.84

-. 82

.87

-. 87 TEC TEH TEH TEC TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH VS3 TEH TEC TEH TEC TEH TEC TEH VS3 TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBAY2

.610 SBAY2

.610

.610

.610 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 5

H 234 c 6

H 6

H 234 c 130 8

96 96 9

5 H

180 7

H 62 7

H 61 7

H 60 21 H

267 21 H

266 12 H

52 6

H 185 7

H 56 22 H

277 22 H

278 13 H

56 13 H

65 12 H

62 6

H 71 5

H 132 6

H 94 6

H 127 6

H 142

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

17 ST Max

CJ) w SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

87 122 143 122 149 122 167 122 32 123 32 123 32 123 36 123 60 123 62 123 108 123 118 123 120 123 166 123 168 123 109 124 121 124 121 124 28 125 38 125 48 125 72 125 120 125

.47 56 PCT

.29 115 PCT

.35 125 PCT

.47 36 PCT

1. 36

.57 101 PCT 91 PCT TBP

.35 82 PCT

. 58 113 PCT

.68 136 PCT

.45 125 PCT

.51 127 PCT

.63 125 PCT

.31 82 PCT

.41 47 PCT

.37 144 PCT

.32 130 PCT

.45 119 PCT

.54 100 PCT

.40 57 PCT

.43 58 PCT

.36 135 PCT

.66 98 PCT 13 10 11 13 25 14 10 15 16 13 14 16 10 12 11 10 13 14 11 12 10 17 P2 BWl P2 BW2 P2 VS3 P2 BW2 P2 BWl P2 08C P2 08C P2 VS3 P2 VS2 P2 BWl P2 VS2 P2 VS2 P2 BW2 P2 BW2 P2 BWl P2 BWl P2 VSl P2 08H P2 BW2 P2 09C P2 VS4 P2 VS2

.81

.88

.84

.90

-. 79

.82

.87

.82

.69

-1.54

. 75

.79 1.10

.98

-1.99

1. 05

. 77

.88

.97

-. 63

1. 01

.79 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH VS3 TEH VS3 TEH VS3 TEH TEC TEH TEC TEH VS3 TEH VS3 TEH VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610

.610

.610 SBAY2 SBAY2 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl 8

H 13 H

13 H

11 H

5 H

5 H

234 c 32 49 46 71 92 92 5

5 H

94 5

H 230 5

H 235 21 H

248 21 H

253 21 H

254 11 H

84 11 H

104 21 H

230 21 H

224 21 H

224 5

H 84 6

H 91 6

H 172 7

H 21 22 H

241

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+ *- - - - + - - - - + - - - - - - - - - + - - - - + - - - - + - - - - + - - - - - - - + - - - - - + - - - - + - - - - - - - - - + - - - - - - - - - + - - - - + - - - - + - - - - - - + - - - - - - + - - - - - - + - - + - - - - - + - - - - - - - - - + - - - - - - - - - +

18 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

130 125 162 125 27 126 27 126 29 126 37 126 41 126 143 126 153 126 108 127 99 128 125 128 129 128 131 128 155 128 159 128 163 128 16 129 18 129 32 129 48 129 50 129 68 129

.37 92 PCT

.02 43 NQI

.40 124 PCT

.40 121 PCT

.50 79 PCT

.37 52 PCT

.42 92 PCT

.31 130 PCT

. 38 113 PCT

. 34 118 PCT

.43 79 PCT

.36 126 PCT

.43 137 PCT

.34 145 PCT

.32 150 PCT

.28 147 PCT

.29 146 PCT

.24 91 PCT

.44 69 PCT

.27 109 PCT

.44 71 PCT

.20 165 PCT

.77 122 PCT 11 11 11 13 11 12 10 12 10 13 11 13 11 11 10 10 8

13 8

12 6

18 P2 VS3 3

TSH P2 08H P2 BWl P2 BWl P2 BWl P2 BWl P2 BW2 P2 VS2 P2 BWl P2 BWl P2 VSl P2 VS3 P2 VS2 P2 VS5 P2 VS5 P2 BW2 P2 VS3 P2 VS3 P2 VS3 P2 09C P2 VS3 P2 VS2

-. 35 2.70

.77

-.88

-1.02

-. 89

-.96

-.89

.91

-1.61

-. 77

.61 1.20

-. 85

.73

.74

.89

.84

.65

-. 81

-1.07

-.84

.73 VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH VS3 TEH VS3 TEH VS3 TEH VS3 TEH TEC TEH TEC TEH TEC TEH VS3 TEC VS3 TEC TEC TEH TEC TEH TEC TEH TEC TEH

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 22 H

246 12 H

75 5

H 85 5

H 85 5

H 89 6

H 90 5

H 143 13 H

27 13 H

22 21 H

205 21 H

192 21 H

179 21 H

177 21 H

176 12 H

81 12 H

79 12 H

77 25 c

366 25 c 367 5

H 139 5

H 223 6

H 177 5

H 246

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

19 ST Max

Ol (11 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

100 129 132 129 136 129 152 129 160 129 17 130 75 130 89 130 163 130 14 131 48 131 72 131 86 131 88 131 88 131 160 131 49 132 119 132 88 133 148 133 15 134 45 134

.31 87 PCT 10

.45 75 PCT 13

.33 99 PCT 10

.34 87 PCT 11

.36 51 PCT 12

.51 57 PCT 14

.35 51 PCT 11

.33 118 PCT 10

.82 88 PCT 19

.43 92 PCT 13

.76 57 PCT 18

.54 73 PCT 15

.24 153 PCT 8

.32 104 PCT 10

.29 80 PCT 10

.21 120 PCT 8

.19 135 PCT 7

.75 99 PCT 20

.39 79 PCT 12

.34 73 PCT 12

.31 113 PCT 10

.55 88 PCT 15 P2 BWl P2 VS2 P2 VS3 P2 VSl P2 BW2 P2 VS3 P2 BWl P2 BWl P2 BW2 P2 08H P2 BWl P2 BWl P2 VS2 P2 BWl P2 VS2 P2 UC P2 08H P2 VS2 P2 BWl P2 BW2 P2 BWl P2 BWl

-. 81

-. 92

.75

-. 87

-. 71

-.96

.73

-. 83

.98

.02

.79

-. 78

.64

-. 69

.72

.87

.72

.89

-.69

-. 89

-. 78

-.84 VS3 TEH TEC TEH TEC TEH TEC TEH TEC TEH VS3 TEH TEC TEH TEC TEH TEC TEH VS3 TEH VS3 TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEH TEH TEC TEH TEC TEH TEC VS3 TEH VS3 TEH

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl 22 H

190 13 H

11 13 H

13 13 H

21 12 H

85 27 H

95 8

H 125 8

H 132 11 H

110 27 H

27 H

9 c 9 c 9 c 9 c 2 c 28 H 2 c 9 c 1 c 27 H

27 H

69 86 50 43 42 42 8

96 49 27 15 65 50

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTI L2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

20 ST Max

Ol Ol Q,

co 01 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

49 134 141 134 155 134 64 135 102 135 130 135 162 135 127 136 133 136 46 137 124 137 126 137 142 137 156 137 160 137 43 138 117 138 50 139 50 139 60 139 156 139 59 140 77 140

.44 72 PCT 13

.36 48 PCT 13

.35 45 PCT 12

.37 73 PCT 11

.27 88 PCT 10

.55 120 PCT 16

.33 92 PCT 11

.22 59 PCT 8

.27 53 PCT 10

.26 131 PCT 9

.28 84 PCT 10

. 33 113 PCT 12

.31 64 PCT 11

.26 50 PCT 10

.46 64 PCT 15

.33 22 PCT 10

.22 20 PCT 9

.52 98 PCT 14

.30 121 PCT 10

.32 125 PCT 10

.27 135 PCT 9

.32 32 PCT 10

.35 132 PCT 11 P2 BWl P2 VS2 P2 VSl P2 BWl P2 VS2 P2 VS3 P2 03C P2 BW2 P2 VS5 P2 BW2 P2 VSl P2 VSl P2 BW2 P2 VS4 P2 BW2 P2 BWl P2 BW2 P2 BWl P2 VS3 P2 VS3 P2 llC P2 BWl P2 BWl

-.92

.84

-. 80

-. 74

.83

-. 83

.82

.62

-1.00

. 77

-. 76

-. 75

-. 91

.87

-.88

-. 91

.71

-.97

-1.19

.81

.79

.49

1. 08 VS3 TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEH TEH TEC VS3 TEH VS3 TEH TEH TEC TEH TEC TEH TEC TEH TEC

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 27 H

48 1 c 56 1 c 63 9 c 80 2 c 101 2 c 87 2 c 71 2 c 114 2 c 117 25 c 291 1 c 85 1 c 84 1 c 76 1 c 69 1 c 67 25 H

236 1 c 102 25 H

225 25 H

225 9 c 97 2 c 133 9 c 123 9 c 114

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

21 ST Max

O')

""' a 00 01 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

129 140 100 141 128 141 136 141 45 142 61 142 119 142 131 142 50 143 74 143 90 143 108 143 112 143 61 144 113 144 119 144 106 145 110 145 114 145 116 145 120 145 120 145

.33 125 PCT

.24 57 PCT

.33 52 PCT

.27 92 PCT

.44 40 PCT

. 29 116 PCT

.44 75 PCT

.38 49 PCT

.65 93 PCT

.38 85 PCT

.25 48 PCT

.34 120 PCT

.31 90 PCT

. 36 117 PCT

.27 120 PCT

.21 123 PCT

.30 97 PCT

.34 90 PCT

.37 106 PCT

.43 60 PCT

.37 69 PCT

.33 50 PCT 11 9

12 10 13 10 14 13 17 12 9

11 10 12 10 8

11 12 13 14 13 12 P2 BWl P2 VS2 P2 VS2 P2 BWl P2 BWl P2 BWl P2 VS3 P2 VS!

P2 BWl P2 BWl P2 10H P2 BWl P2 BWl P2 BWl P2 VSl P2 VS2 P2 BWl P2 BWl P2 BWl P2 BWl P2 BWl P2 VS2

.69

.74

.90

-. 78

-. 95

.99

-. 79

-. 72

-.82

-.84

-1. 25

-1.86

-. 73

.99

.54

.86

-1. 31

-. 08 1.11

1. 05

.74

.89 TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEH TEH TEC TEH TEC TEH TEC VS3 TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

. 610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

. 610 SBAY2 2 c 174 7 c 108 1 c 139 1 c 135 25 H

188 7 c 246 1 c 159 1 c 165 25 H

179 9 c 131 7 c 87 2 c 214 2 c 212 10 c 23 2 c 223 2 c 226 1 c 203 1 c 201 1 c 199 1 c 198 1 c 196 1 c 196

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 j

+----+----+--"------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

22 ST Max

Ol 00 S?,

00 01 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

45 146

.56 73 PCT 15 P2 BWl

-.89 VS3 TEH

.610 NBAZl 25 H

142 107 146 46 147 48 147 76 147 104 147 112 147 118 147 126 147 65 148 115 148 117 148 121 148 127 148 129 148 124 149 124 149 126 149 126 149 128 149 150 149 150 149 109 150 111 150

.36 56 PCT

.41 105 PCT

.50 104 PCT

. 34 112 PCT

.39 65 PCT

.32 134 PCT

.33 95 PCT

.65 102 PCT

.35 129 PCT

.36 99 PCT

.28 77 PCT

.55 112 PCT

.30 39 PCT

.32 158 PCT

.34 140 PCT

.26 34 PCT

.28 67 PCT

.36 40 PCT

.29 46 PCT

.29 138 PCT

.25 109 PCT

.29 45 PCT

.31 74 PCT 12 12 17 11 12 11 11 18 11 12 10 16 10 11 12 10 10 13 11 11 10 11 11 P2 BWl P2 BWl P2 09C P2 VS2 P2 BWl P2 BWl P2 BWl P2 VS3 P2 VS3 P2 VS2 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 BW2 P2 VS2 P2 BW2 P2 VS2 P2 llH P2 BWl P2 VS2 P2 BWl 1.69

-. 92

-1.25

-. 70

-1.22

-1.14

-. 83

-. 95

-. 76

.75

.76

.87

.98

.96

-.85

.77 1.13

. 78

-. 77

.58

-. 51

-. 90

-.95 TEH TEC VS3 TEH VS3 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 1 c 206 25 H

133 24 c 189 10 c 35 2 c 268 2 c 264 2 c 261 2 c 258 10 c 51 2 c 275 2 c 276 2 c 278 2 c 281 4 c 5

1 c 246 1 c 246 1 c 243 1 c 243 1 c 242 1 c 231 1 c 231 1 c 259 1 c 260

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

23 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CR LEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

115 150 117 150 125 150 127 150 131 150 48 151 50 151 72 151 110 151 110 151 134 151 81 152 81 152 131 152 128 153 130 153 132 153 35 154 133 154 64 155 128 155 134 155 63 156

.27 41 PCT

.46 93 PCT

.26 81 PCT

.38 76 PCT

.38 106 PCT

.36 110 PCT

.18 122 PCT

.45 108 PCT

.37 149 PCT

.40 129 PCT

.20 40 PCT

.38 96 PCT

.45 85 PCT

.30 151 PCT

.31 45 PCT

.37 82 PCT

.48 98 PCT

.31 141 PCT

.29 105 PCT

.42 133 PCT

.36 152 PCT

.37 160 PCT

.47 40 PCT 10 15 10 13 12 13 8

14 12 13 8

12 14 10 10 12 14 10 10 13 12 12 14 P2 VS5 P2 VS3 P2 VSl P2 BW2 P2 VSl P2 09C P2 VS3 P2 VS4 P2 BWl P2 VS2 P2 VS3 P2 VS4 P2 09C P2 VSl P2 BW2 P2 VS2 P2 VSl P2 BWl P2 BW2 P2 08C P2 VS4 P2 BWl P2 09C

.45

-. 80

.92

.84

.97

-1.15

-. 74

-. 90

-. 72

-.69

-. 97

.93

-1.04

-. 77

.92

-. 83

.71

-.65

-1. 01

.75

-. 58

-. 93

-.89 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEC VS3 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 1 c 262 1 c 263 1 c 267 1 c 268 3 c 5

24 c 146 24 c 147 10 c 4 c 4 c 4 c 10 c 10 c 4 c 3 c 3 c 3 c 25 H

3 c 10 c 4 c 4 c 10 c

  • 54 43 43 31 74 74 63 34 33 32 60 62 91 78 75 114

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

24 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

69 156 77 156 108 157 118 157 130 157 130 157 142 157 142 157 144 157 144 157 75 158 81 158 81 158 119 158 137 158 56 159 60 159 62 159 140 159 37 160 79 160 81 160 85 160 129 160

.31 85 PCT 10

.16 153 PCT 6

.45 100 PCT 14

.61 85 PCT 17

.32 114 PCT 11

.92 108 PCT 22

.37 144 PCT 12

.34 57 PCT 11

.69 121 NQI

.86 99 PCT 21

.21 138 PCT 8

.33 132 PCT

. 21 116 PCT

.29 109 PCT

.25 59 PCT

.37 139 PCT

.28 103 PCT

.45 102 PCT

.39 130 PCT

.31 45 PCT

.33 145 PCT

.30 139 PCT

.32 135 PCT

.24 159 PCT 11 8

10 9

12 10 14 12 11 11 10 11 9

P2 09H P2 08C P2 BWl P2 BWl P2 VS4 P2 VS5 P2 llH P2 BWl Pl TSH P2 VS3 P2 08H P2 VS2 P2 09C P2 BW2 P2 VS3 P2 VS3 P2 BWl P2 VS3 P2 BWl P2 BWl P2 VS2 P2 VS4 P2 VS2 P2 VSl 1.19 1.08

-1. 74

-. 70

-. 73

-. 85

.80

-. 77

.71

-1. 01

.97

-. 96

-. 91 1.22

-. 82

-. 76

.98

-. 85

-. 77

-.64

-. 76

.98

-. 82

.88 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC VS3 TEH TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2 10 c 111 10 c 107 3 c 85 3 c 80 3 c 74 3 c 74 3 c 68 3 c 68 3

c 25 3

c 25 11 c 122 11 c 119 11 c 119 3 c 96 3 c 105 10 c 118 10 c 120 10 c 121 3 c 109 26 H

14 10 c 137 10 c 136 10 c 134 4 c 161

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

25 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

133 160 48 161 128 161 132 161 83 162 85 162 111 162 44 163 92 163 120 163 37 164 43 164 83 164 111 164 133 164 48 165 128 165 134 165 134 165 47 166 55 166 107 166 107 166

.35 142 PCT

. 75 118 PCT

.37 101 PCT

.32 156 PCT

.18 123 PCT

.29 116 PCT

.27 96 PCT

.32 121 PCT

.23 120 PCT

.31 141 PCT

.43 75 PCT

.26 96 PCT

.29 54 PCT

.72 149 PCT

.31 128 PCT

.31 99 PCT

.27 157 PCT

.53 102 PCT

.29 72 PCT

.42 132 PCT

. 29 117 PCT

.34 87 PCT

.61 96 PCT 12 19 12 11 7

10 10 12 8

11 15 10 10 19 11 12 10 16 10 14 10 11 17 P2 VS5 P2 09C P2 VS4 P2 BW2 P2 09H P2 VS4 P2 VS2 P2 BWl P2 BW2 P2 VS3 P2. BWl P2 BWl P2 08C P2 VS3 P2 BWl P2 09C P2 VS2 P2 BWl P2 VS3 P2 VS3 P2 BWl P2 VS2 P2 VS3

-. 78

-1. 25

-. 77

.92

.88

.83

-.80

-.84

-. 86

.71

1. 00

.96

-. 81

-.88

-.15

-1.00

-. 80

-.58

-. 73

-. 75

1. 22

-.80

-. 79 TEH TEC VS3 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 NBAZl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2 4 c 128 25 c 24 3 c 130 4 c 127 11 c 153 11 c 152 3 c 146 232 c 56 6 c 194 4 c 167 232 c 41 232 c 44 10 c 166 4 c 182 3 c 121 232 c 5

4 c 123 3 c 115 3 c 115 230 c 304 11 c 205 3 c 170 3 c 170

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

26 ST Max

8.

(JO 01 SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

111 166 111 166 131 166 38 167 58 167 60 167 70 167 76 167 52 169 76 169 106 169 106 169 128 169 111 170 125 170 48 171 84 171 120 171 122 171 35 172 39 172 65 172 121 172 1.08 108 PCT 24

.32 132 PCT 11

.35 67 PCT 12

.35 141 PCT 12

.32 54 PCT 11

.31 19 PCT 10

.55 127 PCT 16

.30 50 PCT 10

.34 87 PCT 11

.20 93 PCT 7

.36 123 PCT

.39 93 PCT

.36 83 PCT

.28 50 PCT

.68 126 PCT

.35 74 PCT

.26 85 PCT

.42 135 PCT 12 13 12 10 18 12 11 13

.88 104 PCT 22

.37 97 PCT 12

.34 32 PCT 11

.27 105 PCT 12

.29 79 PCT 10 P2 VS3 P2 BW2 P2 VS3 P2 BWl P2 BWl P2 09C P2 VS2 P2 08C P2 VS3 P2 VS2 P2 BWl P2 BW2 P2 VS3 P2 BWl P2 VS3 P2 09C P2 VS2 P2 VS3 P2 VS3 P2 BWl P2 BWl P2 VS3 P2 10H

-.88

-.95

-.92

.86

-. 61

-. 79

-. 95

-.88

-. 70

.88

-1.22

-1.22

-.81

.94

.46

-1.79

-.92

-. 91

-1.00

.97

-.66

-.82

-. 33 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2 3 c 172 3 c 172 3 c 119 230 c 268 10 c 181 10 c 182 10 c 187 10 c 190 231 c 226 11 c 217 3 c 190 3 c 190 3 c 116 3 c 201 3 c 192 230 c 210 13 c 11 4 c 209 3 c 206 231 c 187 231 c 185 13 c 32 3 c 207

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

27 ST Max

s.

O>

c.n SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 2!1l1611l411ll lll4/25/211l16 lll8:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UTILl UTIL2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

16 173 6(1) 173 108 173 118 173 122 173 122 173 59 174 75 174 llll7 174 6(/)

175 8(1) 175 88 175 116 175 116 175 87 176 44 177 82 177 84 177 31 178 75 178 113 178 26 179 44 179

.32 125 PCT

.27 121 PCT

.28 136 PCT

.34 131 PCT

.55 98 PCT

.62 105 PCT

.52 63 PCT

.25 llll6 PCT

.27 64 PCT

.22 911l PCT

.41 29 PCT

.29 152 PCT

.28 69 PCT

.28 135 PCT

.35 147 PCT

.311l 97 PCT

.32 102 PCT

.32 128 PCT

.32 llll6 PCT

.25 122 PCT

.34 llll9 PCT

.27 64 PCT

.34 132 PCT 1(/)

llll 9

11 16 17 16 llll 9

llll 15 llll 1(/)

10 11 llll 11 12 11 llll 13 10 12 P2 lll8H P2 VS3 P2 BWl P2 VS3 P2 VS3 P2 VS3 P2 BWl P2 VS2 P2 VS3 P2 lll8C P2 BW2 P2 VS3 P2 BWl P2 VS3 P2 VS2 P2 BWl P2 VS3 P2 VS2 P2 VS3 P2 VS2 P2 VS3 P2 VS3 P2 BW2

-. 77

-.91

-1.35

. 74

-.91

.84

.86

.80

-. 72

.72

.73

.67

-. 35

-. 95

-. 74

-. 87

.61

.76

-. 76

-. 8(1)

.62

.98

-. 73 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.6llll SBAYl

.6111l SBAY2

.6111l SBAY2

.6111l SBAY2

.610 SBAY2

.6llll SBAY2

.6llll SBAY2

.610 SBAY2

.6llll SBAY2

.61!1l SBAY2

.610 SBAY2

.6111l SBAY2

.6111l SBAY2

.6111l SBAY2

.6111l SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.6llll SBAYl

.6111l SBAY2

.6111l SBAY2

.610 SBAYl

.610 SBAYl 231 c 158 12 c 2(1) 6 c 51 3 c 211 3 c 195 3 c 195 12 c 24 12 c 34 6 c 56 13 c 58 13 c 48 6 c 67 3 c 213 3 c 213 6 c 94 231 c 126 12 c 42 12 c 41 23(1) c 137 12 c 64 5 c 12 23(/)

c 109 23(/) c 118

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

!DX UT Ill UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

28 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

48 179 52 179 76 179 39 180 77 180 109 180 52 181 106 181 31 182 41 182 85 182 101 182 103 182 58 183 76 183 96 183 98 183 102 183 48 185 98 185 98 185 17 186

. 56 111 PCT

.37 156 PCT

.23 63 PCT

.30 124 PCT

.25 129 PCT

.42 115 PCT

.38 137 PCT

.52 109 PCT

.28 58 PCT

. 35 118 PCT

.45 117 PCT

.34 132 PCT

.61 105 PCT

.24 73 PCT

.37 108 PCT

.39 107 PCT

.29 107 PCT

.50 135 PCT

.43 112 PCT

.24 130 PCT

.30 109 PCT

.37 80 PCT 17 13 11 10 11 13 12 15 10 12 15 11 16 11 15 12 9

14 13 8

10 13 P2 09C P2 BWl P2 VS2 P2 BW2 P2 BW2 P2 VS3 P2 BWl P2 VS3 P2 BWl P2 BW2 P2 VS2 P2 VS3 P2 VS3 P2 VS3 P2 VS2 P2 VS3 P2 VS3 P2 VS3 P2 09C P2 VS2 P2 VS4 P2 VS3

-.99

-. 91

.93

-.98

-. 94

-1. 00

-. 83

-.98 1.08

-. 76

-. 77

-.95

-. 92

-. 57

-. 64

-.94

-1.04

.85

-.96

.50

-. 71

-. 87 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAYl

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAY2

.610 SBAYl

.610 SBAY2

.610 SBAY2

.610 SBAYl 230 c 120 230 c 122 13 c 85 231 c 96 13 c 108 9 c 135 231 c 87 9 c 136 230 c 91 230 c 86 12 c 101 9 c 142 9 c 141 13 c 127 13 c 117 9 c 154 9 c 155 9 c 139 231 c 37 9 c 158 9 c 158 230 c 54

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2 J

+- - - -+- - - -+- - - - - - - - -+- - - -+- - - -+- - - -+- - - - - - -+- - - - -+- - - -+- - - - - - - - -+- - - - - - - - -+- - - -+- - - -+- - - - - -+- - - - - -+- - - - - -+- -+- - - - -+- - - - - - - - -+- - - - - - - - -+

29 ST Max

SG - 12 Calls of Interest Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 08:22:19

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

19 186

.28 144 PCT 10 P2 VS3 23 186

.37 119 PCT 13 P2 VS3 25 186

.48 96 PCT 15 P2 VS3 87 186

.33 108 PCT 11 P2 VS2 93 186

.31 85 PCT 10 P2 BWl 32 187

.34 145 PCT 12 P2 VS3 38 187

.47 50 PCT 15 P2 VS3 42 187

.29 116 PCT 11 P2 VS3 52 187

.31 58 PCT 11 P2 BWl 54 187

.31 39 PCT 13 P2 BWl 63 190

.26 82 PCT 10 P2 BWl 45 192

.31 74 PCT 10 P2 BWl 29 194

.24 127 PCT 9

P2 VS3 56 195

.32 153 PCT 13 P2 BW2 64 195

1. 63 38 DTI P5 TSH 6

203

.33 106 PCT 12 P2 04C 8

203

.17 148 NQI Pl TSC 14 203

.34 129 PCT 11 P2 04C

-. 87

-.94

-.93

. 78

.87

-.86

-. 90

-. 91

-. 93

-1.03

.93

-. 83

.82

-1.25

. 05

. 74

.54

.82 TEH TEC

.610 SBAYl TEH TEC

.610 SBAYl TEH TEC

.610 SBAYl TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 TEH TEC

.610 SBAYl TEH TEC

.610 SBAYl TEH TEC

.610 SBAYl TEH TEC

.610 SBAYl TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 TEH TEC

.610 SBAY2 230 c 53 230 c 51 230 c 50 9 c 163 9 c 160 230 c 26 230 c 29 230 c 31 230 c 36 13 c 159 12 c 153 19 c 124 18 c 93 13 c 195 12 c 189 16 c 46 16 c 45 18 c 6

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTI L2 I

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

30 Tubes: 611 Records: 701 ST Max

APPENDIXD PLI & PLP DATA SHEETS 76 of 85

SG - 11 SI PlP Calls Palo Verde 1 UlR19 PVNGSl 20160401 04/25/2016 16:05:22

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

I ROW COL VOL TS DEG

!ND PER CRLEN CHN LOON INCHl INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2[

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

164 75 5.06 94 PLP 92 09C 33.57 VS3 TEC

.610 ZYAX2 28 c 76 HR I

164 75 18.86 72 PLP 8

09C 34.00 09C 10C

.600 NPAHZ 30 c 8

HR DOA[

I 165 76 2.20 107 PLP 60 09C 34.20 VSJ TEC

.610 ZYAX2 28 c 77 HR

[

-.J 165 76 10.19 64 PLP 8

09C 34.05 09C 10C

.600 NPAHZ 30 c 10 HR DOA!

-.J I

s.

32 79 19.94 113 PLP 76 TSH

.49 01H TEH

.610 ZYAX2 44 H 14 HR I

CX>

32 79 51.49 81 PLP 8

TSH

.35 TSH 01H

.580 NPUFZ 46 H

9 HR DOA[

01 I

33 80 4.50 79 PLP 164 TSH

.94 01H TEH

.610 ZYAX2 44 H 13 HR I

33 80

10. 91 94 PLP 8

TSH

.56 TSH 01H

.580 NPUFZ 46 H

11 HR DOA[

l 32 81

13. 70 97 PLP 164 TSH 1.66 01H TEH

.610 ZYAX2 44 H 19 HR I

32 81 41.18 84 PLP 8

TSH 1.34 TSH 01H

.580 NPUFZ 46 H

13 HR DOA!

I 3 192 13.08 105 PLP 72 03H 33.35 08H TEH

.610 ZYAX2 41 H

12 HR I

3 192 28.22 75 PLP 8

03H 33.27 03H 04H

.580 NPUFZ 46 H

17 HR DOA[

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

[ ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL2[

+----+--*-+-*-*-*---+***-+****+***-+*****--+*****+**-*+--*-*****+**-**-***+****+****+******+******+******+**+*****+---*-****+-*-*-**-*+

--J CX>

s.

CX>

01 SG - 12 SI PLP Calls Palo Verde 1 U1R19 PVNGSl 20160401 04/25/2016 16:05:22

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

t ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCHl INCH2 BEGT ENDT PDIA PTYPE CAL l

IDX UTILl UTIL2(

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

76 163 16.13 90 PLP 160 TSH

.68 01H TEH

.610 ZYAX2 29 H

16 SR(

76 163

39. 64 82 Pl P B

TSH

. 83 TSH TSH

. 600 NPAHZ 35 H

7 SR DQA(

+----+----+---------+----+----+-***+*-**---+-****+----+---------+-------*-+***-+----+------+------+-*****+*-+*-*--+---------+---------+

( ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH!

INCH2 BEGT ENDT PDIA PTYPE CAL L

IDX UTILl UTIL21

+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+

APPENDIXE PLUG MAPS 79 of 85

co 0

Q, co

(]1 SG - 11 Tubes Plugged in U1R19 Palo Verde U1 R19 PVNGS11RSG 170 165 160 155 150 145 140 135 130 125 120 115 110 105 100 95 90 as 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10

  • 53 Stay Rod a 88 Plugged Tu be
  • 23 Tube Plugged ln U1R19 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200

~-+-~t--+-~+---+~-+-~+--+-~+---+~-+-~+---+~-+-~t--+-~+---+~-+--'-+---+~+---ll---+-~+---+~-+-~t--+-~+---+~-+-~+---+~+---+~-+-~+--+-~+- 1 7 0

~-+-~t--+-~+---+~-+-~+--+-~+---+~-+-~+---+~-+-~t--+~+---+~-+-.;....;;.+---+~-+---ll---+-~+---+~-+-~t--+-~+---+~-+-~+---+~+---+~-+-~+--+-~+- l 6 5

~-t-~t---t-~+---t~-t-~+--t-~+---+~-t-~+---+~-+-~t---+~+---+~-t-~+---+~+---+l---+~+---+~-+-~t--+~+---+~-+~+---+~+---+~-+~+--+~+-- l 60

~-t-~t--t-~+---+~-+-~+--+-~+---+~-+~+---+~-+-~t--+-~+---+~-+-~+---+~-+---+l---+~+---+~-+-~1---+-~+---+~-+-~+---+~+---+~-+~+--+-~+-- 1 55

~-t-~t---t-~+---+~-+-~+--+~+---+~-+~+---+~-+-~t--+-~+---+~-+-~+---+~+---+l---+~+---+~-+-~t--+~+---+~-+~+---+~+---+~-+~+--+~+-- l 5 0

~-+-~t--+-~+---+~-+-~+--+-~-+---+~-+-~+---+~-+-~t--+-~+---+--'-+-~+---+~-+---11---+-~+---+~-+-~l---+-~+---+~-+-~+---+~+---+~-+-~+--+-~+- 1 45

~-1-~t--+~+---+~-+-~+--+-~-+---+~-+-~+---+~-+-~t--+-~+---+~-+-~+---+~-+---11---+-~+---+~-+-~t--+-~+---+~-+-~+---+~-+---+~-+-~+--+-~+- 1 4 0

~-+-~+--+-~+---+~-+-~+--+-~-+---+~-+-~+---+~-+--'-t--+~+---+~-+--'-+---+~-+---ll---+--'-+---+~-+-~t--+----'+---l~-+-~+---+~-+---+~-+-~+--+-~+- 13 5

~-+---<l---+-~+--+~-+-~1---+-~+---+~-+-~+--+~-+---<l---+-~+---+~-+-~l---+~+---+~-+-~+--+~-+---<~-+-~+---+~-+-~1---+~+---+~-+---<l---+-~+-- 1 3 0

~-1-~t--+~+---+~-+-~+--+~-+---+~-+~+---+~-+-~t--+'---+---i~-+-~+---+~-+---11---+-~+---+'---+-~t--+-~+---+~-+-~+---+~+---+~-+~+--+~+-- 125

~-+---<1---+-~+--+~-+-~1---+-~+---+~-+-~+--+~-+---<l---+-~+--+~-+-~1---+~+---+~-+-~+--+~-+---<~-+-~+--+~-+-~1---+~+--+~--t---<l---+-~+-- 1 2 0

~-+---+1---+~+---+~-+-~t--+~+---t~-t-~+--+~+---11---+~+---+~-+-~t--+~+---+~-t-~+---+~+---1>---+--,+---+~-t-~t--+-~+---t~-t---i1---+~+- 1l 5

~-+---ll---+-~+---+~-+-~t--+-~+---+~-+-~+--+-~-+---lf'---+-~+---+~-+-~t--+-~+---+~-+--'-+---+~+---ll---+-~+---+~-+-~t--+-~+---+~-t---'l---+-~+-11 0

~-+---<l---+-~+--+~-+-~1---+-~+--+~-+-~+--+~-+---<l---+-~+--+~-+-~1---+~+---+~-+-~+--+~-+---<l---+-~+--+~-+-~1---+~+--+~-+-----=l---+-~+-- 1 0 5

~-+---ll---+-----=+---+~-+-~t--+-~+---+~-+-~+--+-~-+---ll---+-~+---+~-+-~t--+-~+--'-l~-t--'-+---+~-+---ll---+-~+---+~-t-~t--+-~+---+~-t-----=l---+-~+- 1 0 0

~-+---ll---+-~+---+~-+-~t--+-~+---+~-+-~+--+-~-+---ll---+-~+---+~-+-~t--+-~+---+~-+-~+---+~-+---11---+-~+---+~-+-~t--+-~+---+~-+-~t--+-~+-9 5

a

~--t---<1---+-~+--+~-+-~1---+-~+--t~-+-~+--+~-+---<l---+-~+--t~-+-~1----+~+---+~-+-~+--+~-+---<l---+-~+--t~-+-~1---+~+--t~-+-~1---+-~+--75

~-t---11---t-~+---+~-+-~t--t-~+---t~-t-~+--+~+-----=l---+~+---+~-+-~t--+~+---+~-t-~+---+~+---11---1-~+---+~-t-~t--+~+---+~-t-~t--+~+- 7 0

~--t---<l---+-~+--+~-+-~1---+-~+--t~-+-~+--+~-+-~1---+-~+--+~-+-~+---+~+---+~-+-~+--+~-+---<l---+-~+--+~-+-~1---+~+--+~-+-~1---+-~+--65

~-+---<l---+-~+--+~-+-~1----+-~-+---+~-+-~+--+~-+-~1----+-~+---+~-+-~+--+~-+---+~-+-~+---+~-+---<l----+-~+---+~-+-~+--+~+---+~-+-~1----+-~+-6 0

~-+---ll---+-~+---+~-+-~t--+-~+---+~-+-~+--+-~-+--'--t--+~+---+~-+--'-t--+----'+---+~-+-~+---+~-+---11---l----'+---+~-+-~t--+-~+---+~-+--'-l---+~+-55

~-+---+l---+-~+---+~-+-~t--+-~+---+~-+-~+--+-~-+-~t--+-~+---+~-+-~l---+-'--+---l~-+-~+---+~-+---11---+-~+---+~-+-~t--+-~+---+~-+-~t--+-~+-5 0

~-t-~t--t-~+---t~-+-~t--t-~+---+~-+-~+--+~-+-~t--t-~+---=t----=..ts~

    • M: r:~::;:~:~:~*=~

= 7* -+---ll---+~+---+~-t-~+--+~+---ll---+~+---+~+---+l---t-~+---+~45

~-t-~1---+-~+---+~-+-~t--+-~+---+~-t-~+---+~-+-~t--+-~+-,,..-

  • *_*-+-~t--+-~*+-
    • ~==~* ~=~* 1---1-~+---+~-t-~+--+-~+---11---+~+---+~+---11---+-~+---+~40

.*a o*o* *

~-t-~t---t-~+---t~-+-~t--+~+---+~-+-~+---+~+-~t---+~

=*~+---i~-t-~+---t~-+--*.,..,,

~~~;-.t----'+---+~-+-~+--+~+---+t---+~+---+~-+---it---+~+---+~35

~-t-~t---+-~+---+~-+-~t--+-~+---+~-+-~+---+~-+-~t---fo~+---+~-+-~t--+-~+---+~-t--.+---+~+---11---+~+---+~-t-~t--+~+---+~-t-~t--+-~+--3 0

~-+-~l---+-~+---+~-+-~l---+-~+---+~-+-~+---+~-+-~i-.~~+---+~-+-~l---+-~+---+~-+-~J---+~-+---11---+-~+---+~-+-~l---+-~+---+~-+-~l---+-~+-25

~-t-~1---+-~+---+~-+-~t--+-~+---+~-+-~+---+~-+-~1---+-~+---+~-t-~t--+-~+---+~-+-~+---+~+---'t---+~+---+~-t-~t--+~+---+-'--+-~t--+~+-- 2 0

~-+-~1---+~+---+~-+-~l---+-~+---+~-+-~+---+~-+---,l---+-~+---+~-+-~t---+~+---+~-+-~+-..,,+~+---'l---+~+---+~-t-~t--+~+---+~-+-~t--+-~+-- l 5

~-t-~t---+~+---t~-+-~t--+-~+---+~-+-~+---+~+-~t---+~+---+~-t-~t---+~+---+~-+-~+---t~+-~t---+-~+---+~-t-~t---+~+---+~-t-~t---+~-r-- 1 0 10 15 20 25 30 36 40 45 50 55 60 65 70 75 60 85 90 95 100 106 110 116 120 125 130 136 141l 146 160 165 160 165 170 175 180 186 190 196 200

SG - 12 Tubes Plugged in U1R19 Palo Verde U1R1 9 PVN GS1 1RSG 53 Stay Rod a 107 Plugged Tu be 23 Tube Plugged in U1R19 10 15 20 25 30 35 40 45 50 55 60 65 70 76 8 0 85 90 95 UHl 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 170 170 165 165 160 160 155 155 150 150 145 145 140 140 135 135 130 130 CX>

125 125

~

8.

120 120 CX>

115 115 110 110 105 106 100 100 95 A5 9 0 0

85

  • 5 80
o 75 75 70 70 65 65 60 60 55 55 50 so
  • a*o

.. *=*=

o "o* *=** :*

45 45

  • *o*o...

40 40 35 35 30 30 25 25 20 20 15 15 10.*

10 10 16 20 25 30 35 40 45 50 65 60 65 70 75 80 85 9 0 95 100 106 110 115 120 125 130 135 141l 146 160 166 160 165 170 176 180 186 190 196 200

'/\\'~m rQ"ic*.ne-tric. C'r.r.o.rrtU.C * $1 Ma. OU2er.'201G 14.M 20

APPENDIXF FORM NIS-1 82 of 85

APS NIS-1 FORM OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS

1. OWNER ARIZONA PUBLIC SERVICE COMPANY, et al la. ADDRESS P. 0. BOX 52034; PHOENIX, ARJZONA 85072
2. PLANT PALO VERDE NUCLEAR GENERATING STATION 2a. ADDRESS 5801 SOUTH WTNTERSBURG ROAD, TONOPAH, ARJZONA 85354
3. UNIT NUMBER I
4. OWNERS CERTIFICATE OF AUTHORIZATION NONE
5. COMMERCIAL SERVICE DATE 1-28-86
6. COMPONENTS INSPECTED:

COMPONENT OR MANUFACTURER SERIAL STATE OR NATIONAL APPURTENANCE OR INSTALLER NUMBER PROVINCE BOARD NO IMRCEEOIA Ansaldo 224 NA 173 STEAM GENERA TOR 11 IMRCEEOIB Ansaldo 225 NA 174 STEAM GENERATORl2 83 of 85

NIS-1 BACK APS OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS

7. EXAM DATES April 2016
8. INSPECTION INTERVAL 7-18-08 to 7-17-18
9. ABSTRACT OF EXAM INATIONS. INCLUDE A LIST OF EXAMINATIONS ANO A TATEME T CO CERNINC STAT S OF WORK REQUIRED FOR CURRE TI TERVAL.

Table I in the report summary section documents the number and type of each examination performed.

A summary of the tubes with indications of degradation is listed in Appendix Band C of this report for SG 11 and 12 respectively. The tubes identified on page 3 were plugged as a result of this examination.

WE CERTIFY THAT THE STATEME TS MADE I THIS REPORT ARE CORRECT A D THE EXAMINATIO S AND CORRECTIVE MEASURES TAKE CONFORM TO THE RULES OF THE ASME CODE, SECTION XI.

Hansen Douglas Digitallysigned by Hansen, 1

Douglas B(Z4 l 530)

DATE _____ SIG ED: ARIZONA PUBLIC SERVICE COMPgtL~Y530) g~;e~~o~~~~e~i~~~~l~~~~z7~~g.3o)

CERTIFICATE OF INSERVICE INSPECTION I, THE UNDERSIGNED, HOLDING A VALID COMM ISSIO ISSUED BY THE AT!ONAL BOARD OF BOILER AND PRESSURE VESSEL INSPECTORS AND THE STATE OF PROVINCE OF ARIZONA EMPLOYED BY HSB CT OF HARTFORD, CO ECT!CUT HA VE INSPECTED THE COMPONE TS DESCRIBED THIS OW ERS REPORT DURING THE PERIOD 04-01-16 TO 10-20-16, AND STATE THAT TO THE BEST OF MY KNOWLEDGE A D BELIEF, THE OWNER HAS PERFORMED EXAMINATIO SAND TAKE CORRECTIVE MEASURES DESCRIBED IN THIS OWNERS REPORT IN ACCORDANCE WITH THE REQUIREME TS OF THE ASME CODE, SECTION XI. BY SIGN! G THIS CERTIFICATE NEITHER THE I SPECTOR OR HIS EMPLOYER MAKES ANY WARRA TY, EXPRESSED OR IMPLIED, CONCER I G THE EXAMl ATIO S A D CORRECTIVE MEASURES DESCRIBED IN THIS OW ERS REPORT.

FURTHERMORE, NEITHER THE INSPECTOR OR HIS EMPLOYER SHALL BE LIABLE I ANY MANNER FOR A Y PERSO AL I JURY OR PROPERTY DAMAGE OR A LOSS OF A Y KIND ARISING FROM OR CONNECTED WITH THJS INSPECTION.

Hog stro m, Digitally signed by Hogstrom, Robert (YH2450)

R b rt (YH2450)

DN: cn=Hogstrom, Robert (YH2450)

INSPECTOR 0 e oate: 2016.10.20 18:00:48-07'00*

COMMISSIO S

.B. 9685 "A,,l,C Az 264 NATL' BOARD, STATE, PROVINCE 84 of 85

APS NIS - 1 BACK (page 3)

OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS Plugged Tubes (Row - Column):

SG 11 SG 12 ROW COL ROW COL 34 123 32 123 35 124 37 120 38 121 39 120 39 120 40 119 41 120 41 80 42 119 41 120 43 114 42 89 43 116 42 117 43 118 42 119 44 89 43 88 44 113 43 90 45 88 43 118 46 109 43 120 47 92 44 91 47 104 44 115 48 95 46 115 48 113 47 84 49 104 47 86 49 106 47 114 49 108 48 97 49 110 49 116 53 108 51 94 121 44 90 101 85 of 85