ML16293A849
Text
Appendix E -
Project Data Quality Parameter Crosswalk
Appendix E - Project Data Quality Parameter Crosswalk Field Data Quality Parameters Data Quality Field Activity-Equipment Calibration
- Operability Acceptance Criteri.a
- Criteria Criteria Met.
Indicator Check Check Identified Y/N (PARCC Parameter)
Precision Soil Samples Duplicate Sample Not Not 10% Relative Quality y
applicable applicable Difference (RPD)
Assurance between duplicates, Project Plan -
1/10 samples and 2 A.6.1, B.5.2.1 duplicates per sub-area Precision No Soil Sample Equipment Not Not Less than Minimum Quality y
Cross-Rinsate Blanks applicable applicable Detectable Assurance Contamination Concentration Project Plan -
(MDC) on equipment A.6.1, B.4.1, rinsate blanks B.5.2.2 Precision No Sample Deionized Water Not Not Less than Detection Quality y
Equipment Blank applicable applicable Limits in DI water Assurance Cross-blanks Project Plan -
Contamination A.6.1, B.4.1, B.5.2.2 Accuracy Course Grid Ludlum 2241-2 Annual Daily {3 Within annual Quality y
Walkover Scaler/Ratemeter calibration.
times/day) calibration, +/-20%
Assurance coupled with Daily source source gross cpm Project Plan -
2"X2" Nal checks.
A.6.1, B.6.1, Gamma Detector B.7.1 and GPS Instrument Accuracy Location Specific Bicron Microrem Annual Daily {3 Within annual Quality y
Static Survey Meter calibration.
times/day) calibration,+/- 20%
Assurance Daily source source uRem/hr Project Plan -
checks.
A.6.1, B.6.1, B.7.1
Appendix E - Project Data Quality Parameter Crosswalk Accuracy Location Specific Ludlum 2241-2 Annual Daily (3 Within annual Quality y
Static Survey Scaler/Ratemeter calibration.
times/day) calibration, +/-20%
Assurance coupled with Daily source source Gross cpm Project Plan -
2"X2" Nal checks.
A.6.1, B.6.1, Gamma Detector B.7.1 Representativeness Walkover Area Global Not Daily.
At designated Quality y
Location Positioning.
applicable.
walkover location.
Assurance System (GPS)
Commercial Verified with Project Plan -
GPS.
multiple GPS' and A.6.1 landmarks.
Representativeness Sample Area GPS Not Daily.
At designated Quality y
Location applicable.
sample location.
Assurance Commercial Verified with Project Plan -
GPS.
multiple GPS' and A.6.1 landmarks.
Representativeness Soil Depth Standard Tape Not Not Samples collected at Quality y
Determination Measure/Ruler applicable.
applicable.
designated depths, Assurance Standard verified by second Project Plan -
measuring technician.
A.6.1 device.
Completeness Sampling Not applicable Not Not 95% of samples Quality y
applicable
- applicable targeted for Assurance Collection Project Plan -
A.6.1 Completeness Data Usability Not applicable Not Not 90% data usability Quality y
applicable applicable Assurance Project Plan -
A.6.1 l -
r Appendix E,.... Project Data Quality Parameter Crosswalk Laboratory Data Quality Parameters Data Quality Indicator Parameter Acceptance Criteria Criteria Identified Criteria Met Y /N (PARCC Parameter)
Precision Relative Percent Difference 10%
Quality Assurance Project y
(RPO)
Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Precision Relative Error Ratio (RER)
< 1.96 Quality Assurance Project y
Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Precision Background Data Initial startup calibration Quality Assurance Project y
Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Precision Count Time Per GEL analytical method Quality Assurance Project y
Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Accuracy Matrix Spike {MS) or GEL QAP Quality Assurance Project y
MS/Matrix Spike Duplicate Plan A.6.1, B.4, B.5.3,
{MSD) analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Accuracy Tracer Percent Recovery (R)
GEL QAP Quality Assurance Project y
Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Accuracy Sample & Standards prep 10%
Quality Asswance Project y
Appendix E - Project Data Quality Parameter Crosswalk Batch Calculations Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Accuracy/Precision Instrument Calibration (Initial 1 per 24 hrs (ICV) 1 per 12 Quality Assurance Project y
& Continuing) hrs (CCV)
Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Accuracy/Precision Frequency of Calibration 1 per 24 hrs (ICV) 1 per 12 Quality Assurance Project hrs (CCV)
Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Accuracy/Completeness 10% Sample and Standards NIST traceable standards Quality Assurance Project y
Traceability Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Representativeness Field and Method Blanks
< MDC and 2s counting Quality Assurance Project y
uncertainty Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5 Completeness Chain-of-Custody (COC) Review Completeness Quality Assurance Project y
- Plan A.6.1, B.4, B.5.3, analytical methods, GEL Quality Assurance Plan, es/er/ms-5