ML16181A251
| ML16181A251 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 11/08/2017 |
| From: | Joseph Sebrosky Japan Lessons-Learned Division |
| To: | Entergy Operations |
| References | |
| CAC MF6086, EPID L-2015-JLD-0020 | |
| Download: ML16181A251 (40) | |
Text
Site Vice President UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 8, 2017 Entergy Operations, Inc.
Waterford Steam Electric Station, Unit 3 17265 River Road Killona, LA 70057-3093
SUBJECT:
NUCLEAR REGULATORY COMMISSION REPORT FOR THE AUDIT OF ENTERGY NUCLEAR OPERATIONS, INC'S. FLOOD HAZARD REEVALUATION REPORT SUBMITTAL RELATING TO THE NEAR-TERM TASK FORCE RECOMMENDATION 2.1-FLOODING FOR WATERFORD STEAM ELECTRIC STATION, UNIT 3 (CAC NO. MF6086; EPID L-2015-JLD-0020)
Dear Sir or Madam:
By letter dated August 25, 2015 {Agencywide Documents Access and Management System (ADAMS) Accession No. ML15231A354), the U.S. Nuclear Regulatory Commission (NRC) informed you of the staff's plan to conduct a regulatory audit of Entergy Nuclear Operations, lnc.'s (the licensee) Flood Hazard Reevaluation Report (FHRR) submittal related to the Near-Term Task Force Recommendation 2.1-Flooding for Waterford Steam Electric Station, Unit 3.
The audit was intended to support the NRC staff review of the licensee's FHRR and the subsequent issuance of a staff assessment.
The audit conducted on March 3, 2016, was performed consistent with NRC Office of Nuclear Reactor Regulation, Office Instruction LIC-111, "Regulatory Audits," dated December 29, 2008, (ADAMS Accession No. ML082900195). The purpose of this letter is to provide you with the final audit report which summarizes and documents the NRC's regulatory audit of the licensee's FHRR submittal.
If you have any questions, please contact me at (301) 415-1132 or by e-mail at Joseph.Sebrosky@nrc.gov.
Docket No. 50-382
Enclosure:
Audit Report cc w/encl: Distribution via Listserv Jos ebrosky, Senior Proj anager Be ond-Design-Basis Management Branch Di sion of Licensing Projects ice of Nuclear Reactor Regulation
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 NUCLEAR REGULATORY COMMISSION AUDIT REPORT FOR THE AUDIT OF ENTERGY NUCLEAR OPERATIONS, INC'S.
FLOOD HAZARD REEVALUATION REPORT SUBMITTALS RELATING TO THE NEAR-TERM TASK FORCE RECOMMENDATION 2.1-FLOODING FOR WATERFORD STEAM ELECTRIC STATION, UNIT 3 BACKGROUND AND AUDIT BASIS By letter dated March 12, 2012, the U.S. Nuclear Regulatory Commission (NRG) issued a request for information to all power reactor licensees and holders of construction permits in active or deferred status, pursuant to Title 1 O of the Code of Federal Regulations (10 CFR),
Section 50.54(f), "Conditions of license" (hereafter referred to as the "50.54(f) letter). The request was issued in connection with implementing lessons-learned from the 2011 accident at the Fukushima Dai-ichi nuclear power plant, as documented in The Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident. Recommendation 2.1 in that document recommended that the NRG staff issue orders to all licensees to reevaluate seismic and flooding hazards for their sites against current NRG requirements and guidance.
Subsequent staff requirements memoranda associated with SECY 11-0124 and SECY-11-0137, instructed the NRG staff to issue requests for information to licensees pursuant to 1 O CFR 50.54(f).
By letter dated July 21, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15204A321 ), Entergy Nuclear Operations, lnc.'s (Entergy, the licensee) submitted its Flood Hazard Reevaluation Reports (FHRRs) for Waterford Steam Electric Station, Unit 3 (Waterford, WSES). The NRC has completed a regulatory audit of the licensee to better understand the development of the submittal, identify any similarities/differences with past work completed and ultimately aid in its review of the licensee's FHRR. This audit summary is being completed in accordance with the guidance set forth in NRC Office of Nuclear Reactor Regulation, Office Instruction LIC-111, "Regulatory Audits,"
dated December 29, 2008 (ADAMS Accession No. ML082900195).
AUDIT LOCATION AND DATES The audit was completed by document review via a webinar session in conjunction with the use of the licensee's established electronic reading room (ERR) and webinar on March 3, 2016.
Enclosure AUDIT TEAM The NRG audit team, and audit partipants were as follows:
NRC AUDIT TEAM Oraanization Victor Hall, Team Leader NRR Lyle Hibler, Technical Lead NRO Andy Campbell NRO Chris Cook NRO Hosuno Ahn NRO Frances Ramirez RIV Stewart Bailey NRR Jessie Quichocho NRA Matthew McConnell NRA Joshua Miller NRR Kevin Roche NRA Scott DeNeale Oak Ridge National Laboratory (ORNL)
David Watson ORNL Sudershan Ganorade ORNL Chris Bender Taylor Enoineering AUDIT PARTICIPANTS Organization Don Bentley Enterav Mike Krupa Enterav Alan Harris Enterav Stephen Picard Entergy Dan Brown AREVA Cindy Fasano AREVA Chad Cox GZA David Leone GZA Brian Furtado GZA DOCUMENTS AUDITED of this report contains a list which details the documents that were reviewed by the NRG staff, in part or in whole, as part of this audit. The documents were located in an ERR during the NRG staff's review. Attachment 2 provides a discussion of the information needs and response to those needs that were addressed as part of the audit. Attachment 3 provides a table of a levee failure analysis.
AUDIT ACTIVITIES In general, the audit activities consisted mainly of the following actions:
Review background information on site topography and geographical characteristics of the watershed.
Review site physical features and plant layout.
Understand the selection of important assumptions and parameters that would be the basis for evaluating the individual flood causing mechanisms described in the 50.54(f) letter.
Review model input/output files to computer analyses such as Hydrologic Engineering Center - Hydrologic Modeling System (HEC-HMS) and FL0-2D to have an understanding of how modeling assumptions were programmed and executed. summarizes specific technical topics (and resolution) of important items that were discussed and clarified during the audit. The items discussed in Attachment 2 may be referenced/mentioned in the staff assessment in more detail.
EXIT MEETING/BRIEFING By letter dated April 12, 2016 (ADAMS Accession No. ML16090A327), the NRC staff issued a summary of the reevaluated flood-causing mechanisms. That letter concluded that the licensee's reevaluated flooding hazard information is a suitable input for assessments associated with Near-Term Task Force Recommendation 2.1 "Flooding." A closeout phone call was held with the licensee on November xx, 2017. The NRC communicated that no findings or oen/unresolved issues remain.
Attachments:
- 1) Waterford Steam Electric Station, Unit 3 Audit Document List
- 2) Waterford Steam Electric Station, Unit 3 Information Needs and Responses
- 3) Waterford Steam Electric Station, Unit 3 Tables and Figures
ATTACHMENT 1 Waterford Steam Electric Station, Unit 3 Audit Document List
- 1.
AREVA, 2014a, "Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Nuclear Power Island Structure Local Intense Precipitation," Rev 000, AREVA Document No. 32-9221496-000 (Entergy Nuclear WF3-CS-15-00018 Rev 0, EC No. 59098, Vendor Document No. 32-9231496-000), 2014, Signed August 13, 2015. Posted to Curtiss-Wright ERR as "Local Intense Precipitation Internal to the NPIS" on September 14, 2015.
- 2.
AREVA, 2014b, "Waterford Steam Electric Station Flooding Hazard Re-evaluation Ice Induced Flooding," Rev 000, AREVA Document No. 32-9227011-000 (Entergy Nuclear WF3-CS-15-00016 Rev 0, EC No. 59098, Vendor Document No. 32-9227011-000),
Signed September 25, 2014. Posted to Curtiss-Wright ERR as "Ice Induced Flooding" on September 14, 2015.
- 3.
AREVA, 2014c, 'Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Channel Diversion," Rev 000, AREVA Document No. 51-9227014-000 (Entergy Nuclear WF3-CS-15-00032 Rev 0, EC No. 59098), Signed September 26, 2014. Posted to Curtiss-Wright ERR as "Channel Diversion" on September 14, 2015.
- 4.
AREVA, 2014d, "Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Local Intense Precipitation," Rev 000, AREVA Document No. 32-9226993-000 (Entergy Nuclear WF3-CS-15-00011 Rev O, EC No. 59098, Vendor Document No. 32-9226993-000), Signed December 16, 2014. Posted to Curtiss-Wright ERR as "LIP External to Nuclear Plant Island Structure" on September 14, 2015.
- 5.
Entergy, 2014e. WSES Procedure Number OP-901-521 (Attachment 4) - "Severe Weather and Flooding," Revision 315, 2015. See AREVA Document No. 38-9243507-000.
- 6.
AREVA, 2015a, "Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Dam Failure," Rev 000, AREVA Document No. 32-9226999-000 (Entergy Nuclear WFS-CS-15-00013 Rev 0, EC No. 59098), Vendor Document No. 32-9226999-000), 2015, Signed January 22, 2015. Posted to Curtiss-Wright ERR as "Dam Failure" on September 14, 2015.
- 7.
AREVA, 2015b, "Waterford Steam Electric Station Flooding Hazard Re-evaluation Probable Maximum Precipitation," Rev 000, AREVA Document No. 32-9233937-000 (Entergy Nuclear WF3-CS-15-00019 Rev 0, EC No. 59098, Vendor Document No. 32-9233937-000), 2015, Signed March 23, 2015. Posted to Curtiss-Wright ERR as "Probable Maximum Precipitation" on September 14, 2015.
- 8.
AREVA, 2015c, 'Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Nuclear Power Island Structure Local Intense Precipitation," Rev 000, AREVA Document No. 32-9231496-000, Entergy Nuclear signed May 1, 2015. Included on hard drive submitted to NRC on September 4, 2015.
- 9.
AREVA, 2015d, "Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Combined Effects," Rev 000, AREVA Document No. 51-9227036-000 (Entergy Nuclear WF3-CS-15-00017 Rev 0, EC No. 59098, Vendor Document No. 32-9227036-000),
Signed June 8, 2015. Posted to Curtiss-Wright ERR as "Combined Effects" on September 14, 2015.
- 10.
AREVA, 2015e, "Wateriord Steam Electric Station Flooding Hazard Re-Evaluation Report," Rev 000, AREVA Document No. 51-9227040-000 (Entergy Nuclear WF3-CS-15-00010 Rev 0, EC No. 58788, Vendor Document No. 51-9227040-00), 2015, Signed July 9, 2015. Posted to Curtiss-Wright ERR as "Flood Hazard Reevaluation Report" on September 14, 2015.
- 11.
AREVA, 2015f, "Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Probable Maximum Flood," Rev 000, AREVA Document No. 32-9226996-000 (Entergy Nuclear WF3-CS-15-00012 Rev 0, EC No. 59098, Vendor Document No. 32-9226996-000), Signed August 13, 2015. Posted to Curtiss-Wright ERR as "Probable Maximum Flood" on September 14, 2015.
- 12.
AREVA, 2015g, "Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Probable Maximum Hurricane," Rev 000, AREVA Document No. 32-9227002-000 (Entergy NuclearWF3-CS-15-00014 Rev 0, EC No. 59098, Vendor Document No. 32-9227002-000), Signed August 13, 2015. Posted to Curtiss-Wright ERR as "Probable Maximum Hurricane" on September 14, 2015.
- 13.
AREVA, 2015h, "Waterford Steam Electric Station Flooding Hazard Re-evaluation -
Probable Maximum Storm Surge," Rev 000, AREVA Document No. 32-9227005-000 (Entergy Nuclear WF3-CS-15-00015 Rev 0, EC No. 59098, Vendor Document No. 32-9227005-000)," Signed August 13, 2015. Posted to Curtiss-Wright ERR as "Probable Maximum Storm Surge" on September 14, 2015.
- 14.
AREVA, 2015i, "Waterford Steam Electric Station Unit 3 Fukushima Flood Hazard Re-evaluation -Topographic Survey," Rev 000, AREVA Document No. 38-9226991-000 (Entergy NuclearWF3-CS-15-00022 Rev 0, EC No. 59098, Vendor Document No. 32-9226991-000), Signed August 13, 2015. Posted to Curtiss-Wright ERR as "Topographic Survey" on September 14, 2015.
- 15.
AREVA, 2015j, "Waterford Steam Electric Station Flooding Hazard Re-evaluation Tsunami," Rev 000, AREVA Document No. 51-9227008-000 (Entergy Nuclear WF3-CS-15-00020 Rev 0, EC No. 59098, Vendor Document No. 51-9227008-000), Entergy Nuclear signed August 13, 2015. Posted to Curtiss-Wright ERR as "Tsunami" on September 14, 2015.
- 16.
Entergy Operations, Inc. (Entergy), 1992, Waterford Steam Electric Station Drawing No.
G-886, "Reactor Building Plan El. 21.00 Plumbing & Drainage", February 6, 1992.
- 17.
Entergy, 2000, "Route OCT Sumps Discharge to Circulating Water System," DC3521 Revision 4, Signed January 26, 2000. Letter dated February 3, 2000.
- 18.
Entergy, 2001, AREVA Document No. 38-9243507-000, Calculation EC-M99-010 Revision 0-2, Signed August 24, 2001.
- 19.
Entergy, 2002, "Route OCT Sumps Discharge to Circulating Water System," DC 3521 Revision 6, Signed May 7, 2002.
- 20.
Entergy, 2013, Final Safety Analysis Report-Revision 307, Letter dated July 11, 2013, ADAMS Accession No. ML13218A409 (Non-Public).
- 21.
Entergy, 2015a, "Waterford Steam Electric Station Flooding Hazard Re-evaluation Report," Enclosure to Letter from Michael R. Chisum to the NRC Document Control Desk,
Subject:
"Flood Hazard Reevaluation Report Waterford Steam Electric Station, Unit 3 (Waterford 3)", July 21, 2015, ADAMS Accession No. ML15204A344.
- 22.
Entergy, 2015b, "Flood Hazard Re-evaluation for Waterford Steam Electric Station,"
Letter from Cynthia Fasano, Advisory Engineer, AREVA Inc. to Victor Hall, Project Manager, U.S. Nuclear Regulatory Commission, Enclosure hard drives of files, September 4, 2015, ADAMS Accession No. ML17208A033.
- 23.
Entergy, 2015c, "(Off Normal Procedure) Severe Weather and Flooding," OP-901-521, Effective Date: 7/2/2015, Signed: 7/20/2015
- 24.
Entergy, 2016a, 'Waterford Steam Electric Station Flood Re-evaluation Audit - March, 2016". Posted to Curtiss-Wright ERR as 'WSES Audit Slides 3-3-16" on March 3, 2016.
- 25.
Entergy, 2016b, 'Waterford Steam Electric Station (WSES) Information Need Responses for the Flood Hazard Reevaluation Report," enclosures Attachment A (for Information Need 1), Attachment B (for Information Need 3), Attachment C (for Information Need 6), Attachment D (for Information Need 7), Attachment E (for Information Needs 10 and 13), Attachment F (for Information Need 12). Posted to Curtiss-Wright electronic reading room (ERR) on January 31, 2016.
Information Need No.
1 2
ATTACHMENT 2 Waterford Steam Electric Station, Unit 3 Information Needs and Responses Information Need Description Figures
Background:
Figures from the Combined Effects Calculation Package (AREVA, 2015b)) will need to be included in the U.S Nuclear Regulatory Commission (NRC) staff assessment.
Request: Provide legible, standalone copies of the following figures from the Combined Effects Calculation Package (AREVA, 2015b):
Figure 5 (FL0-20 Model Layou~
Figure 6 (FL0-20 Manning's Roughness Coefficient Rendering)
Figure 11 (Selected Locations at Waterford Steam Electric Station
[WSES] for Reporting Results)
Figure 40 (Water Level Timeseries Plot for Storm 302 in WSES Plant Datum
[feet, Mean Sea Level (MSL)])
Figure 41 (Water Level Timeseries Plot for Storm 402c in WSES Plant Datum
[feet, MSL])
All Flood-Causing Mechanisms - Comparison of Reevaluated Flood Hazard with Current Design Basis
Background:
Recommendation 2.1 of the 50.54(f) letter {NRC, 2012) provides instructions for the Flood Hazard Reevaluation Report {FHRR). Under Section 1, Hazard Reevaluation Report, Items c and d, licensees are requested to perform:
Response
Attachment A of the response {Entergy, 2016a) provided the requested figures.
The NRC staff reviewed the response and concluded the information provided was sufficient to resolve the information need. The staff and the licensee agreed the staff could use the following figures from the response in the staff assessment:
- 1. Figure 6: FL0-20 Manning's Roughness Rendering
- 2. Figure 11: Selected Locations at WSES for Reporting Results The response (Entergy, 2016a) stated that "[f]or the purposes of the WSES FHRR, the two terms, design basis and licensing basis, can be considered to have the same meaning and may be used interchangeably."
The licensee stated in the response that "flood levels reported within the Mississippi River refer to flooding that remains within the bounds of the Mississippi River levee network. Flood levels reported as beina at the WSES site refer to floodina within the
Information Information Need Description
Response
Need No.
- c. Comparison of current and reevaluated flood plain (no longer bound by the levee network) that could flood-causing mechanisms at the site.
inundate the site. Where not specified (i.e. FHRR Table 4-1 Provide an assessment of the current design probable maximum storm surge [PMSS] from Gulf of Mexico),
basis (COB) flood elevation to the the flood elevation refers to the WSES site. The COB includes reevaluated flood elevation for each flood flood levels both within the Mississippi River levee network, as causing mechanism. Include how the well as flood levels outside of the levee network which could findings from Enclosure 4 of this letter (i.e.,
potentially inundate the area around the site structures (i.e.,
Recommendation 2.3 flooding walkdowns) inundation of the flood plain outside of the levee network)".
support this determination. If the COB flood The licensee stated that "[t]he LIP Dry Cooling Tower (OCT) bounds the reevaluated hazard for all flood-causing mechanisms, include how this flood values reported in Table 4-1 are provided in terms of depth, not elevation. This is due to the varying relevant finding was determined.
elevations of the two OCT basins. The elevation important to
- d. Interim evaluation and actions taken or safety for the DCTs is the height (above the floor) of the lowest planned to address any higher flooding electrical termination in the Motor Control Center (MCC) in hazards relative to the design-basis, prior to either of the OCT basins. Additionally, pooling water will impact completion of the integrated assessment the sump pump motors prior to reaching the level of the MCCs.
described below, if necessary.
The specific elevations are described below (from EC-M99-010). These elevations are based on a survey and may vary The FHRR for the WSES site mentions both the relative to design drawings".
design-basis and licensing basis when comparing to reevaluated flood hazards and it is not clear which The response provides OCT A elevations (relative to MSL) for is correct due to inconsistencies. For example, in the floor, the sump pump motor, the MCC critical, and the Section 4.0 the text tends to refer to the licensing reevaluated flood, and OCT B elevations (relative to MSL) for basis, but for the flood elevation comparison the floor, the sump pump motor, the MCC critical, and the presented on Table 4-1 the same values are reevaluated flood.
referred to as the design-basis. It is particularly The licensee stated in its response that "[f]or the purpose of unclear if the 1.6 feet (ft.) Dry Cooling Tower ponding level is a design or licensing basis since impacting site safety, the MCC height and elevation for OCT B the reference for this level is WSES Calculation EC-is considered the controlling parameter and "[t]he design-basis M99-010, Revision 0-2, August 2001 (Entergy, for the internal LIP is described in UFSAR Section 2.4, pages 2001 a) not the revised WSES Updated Final Safety 2.4-9 and 2.4-10. EC-M99-010 provides the technical basis for Analysis Report (UFSAR) (Entergy, 2013). There is the UFSAR discussion regarding internal LIP flooding."
also some ambiguity in the wording of the FHRR which causes confusion with whether the design The NRC staff determined that ponding depths rather than basis or licensinq basis levels are for the Mississippi water surface elevations (WSE) were acceptable for Information Need No.
3 Information Need Description River or are established at the WSES site which is in the floodplain.
In addition, the local intense precipitation (LIP) internal to the Nuclear Plant Island Structure (NPIS) values presented in the FHRR are reported as ponding depths and not elevations and therefore, the FHRR does not currently provide flooding elevations for the LIP internal to the NPIS analysis in Section 3.1 or in the Flood Elevation Comparison table, Table 4-1.
Request: Clarify the inconsistencies identified in the FHRR with regard to the comparison of the reevaluated flood hazard to the COB and submit a revised hazard comparison consistent with the instructions provided in the §50.54(f) letter.
Also clarify whether the LIP values are ponding depths or elevations. If the values are ponding depths, provide the flood elevations.
General - Nuclear Plant Island Structure
Background:
Section 2.2 of the FHRR (Entergy, 201 Sa) describes the NPIS as a rectangular, box-like reinforced concrete structure, surrounded by a wall with a minimum protection elevation of 29.25 ft.
Mean Sea Level (MSL). The FHRR notes that all structures, systems and components (SSCs) important to safety are flood protected by the NPIS enclosure.
Request: Describe the locations and elevations of the pumps within the NPIS, the conveyances through which the water is pumped, and the pump discharqe points. Provide a detailed diaqram Response characterization of the reevaluated LIP hazard within the NPIS.
The NRC staff reviewed the response and concluded that the information provided by the licensee was sufficient to address the information need request. The staff and the licensee agreed the staff could use the following figure from the response in the staff assessment:
- 1. Figure 3-1 Motor-Driven Pump Locations The response (Entergy, 2016a) refers to Figure 3-1 as provided in Attachment B, which is an update of FHRR Figure 3-4. The staff noted the updated figure includes the locations of multiple motor-driven pumps. The licensee also included the following clarifying response:
"The motor driven pumps discharge to the circulating water system and the storm drainage network (see Figure 3-7; modified from plant drawing G173). The diesel drive pumps discharge over the NPIS wall, at elevation 30 ft MSL (see Figure 3-7, "Dry Cooling Tower Pump Routing" in Attachment B [to Entergy, 2016a])."
Information Information Need Description
, Need No.
Response
illustrating this information as a part of the The response references AREVA, 201 Sa; Entergy, 2001 b; response.
Entergy, 1992a; Entergy 1992b; Entergy1998* and Entergy 2012 1*
The NRC staff reviewed the response and concluded that the information provided by the licensee was sufficient to address the information need request.
4 LIP - Precipitation The licensee stated (Entergy, 2016a) that Hierarchical Hazard
Background:
Evaluation of LIP flooding effects in Assessment (HHA) was used for the LIP analysis but that the the F~RR f?cused on two separate analyses: 1) a HHA approach for the LIP analysis outside the NPIS and inside two-d1mens1onal hydrodynamic simulation of the ~PIS differed. As the first condition, the licensee flooding outside of the NPIS using FL0-2D PRO considered that LIP flooding on the exterior of the NPIS could and 2) a mass-balance approach to simulate challenge the protection of the areas within the NPIS via ingress flooding within the NPIS (see WSES FHRR, AREVA from areas external toward areas internal to the NPIS. As a Document No. 32-9231496-000, and AREVA second condition, the licensee considered that LIP directly over Document No. 32-9226993-000) (Entergy, 201 Sa; the interior of the NPIS could challenge the SCCs within the AREY.A, 2015a; AREVA, 2014). Although a site-NPI~.. The licensee applied the HHA approach to both of these spec1f1c probable maximum precipitation (ssPMP) cond1t1ons separately and this found that the HHA process study was conducted for LIP, it appears that the termi.n.ated at different phases for both of these LIP flooding rainfall hyetograph resulting from this study was cond1t1ons. These two conditions are distinguished by use of used for the mass-balance approach for simulating the HMR probable maximum precipitation (PMP) for the exterior flooding within the NPIS, but higher NPIS and the ssPMP for the interior NPIS.
Hydrometeorological Report (HMR) values are used Outside of the NPIS: The licensee stated that no SSCs are for the two-dimensional model for simulating flooding outside the NPIS.
located outside of the NPIS.
R~que~t: Discuss the rationale for using different HMR-based PMP values (more conservative than ssPMP ra1nfall 1nputs for the two LIP evaluations and how valu~s) were ~sed for the external NPIS analysis. The available this impacts the predicted flooding levels inside the physical marg1.n w~s not exceeded using the HHA process, so NPIS and outside the NPIS.
refinement (pnmanly addition of realism) of the review was stopped for the LIP analysis external to the NPIS. An analysis
~ased on an ss~~P would only increase the margin. The licensee stated 1n its response that the (vertical) available 1 Figures from these sources were provided by the licensee as Attachment B to Entergy (2016a).
Information Information Need Description Need No.
Response
physical margin between the ground surface just outside the NPIS and the 29.25 ft. MSL protection level ranges from 11.6 to 14.9 ft.
Inside the NPIS: All WSES SSCs are internal to the NPIS which is protected from external flooding to elevation 29.2S ft.
MSL with watertight doors at elevations lower than that elevation. The available physical margin is smaller inside the NPIS (about 1.6 ft. of flooding depth) than outside of the NPIS and therefore, a more realistic rainfall analysis approach (i.e., an ssPMP) was used. The licensee stated that ssPMP was more
~ealist_ic due to the historical storms considered in the analysis, including the use of more recent events than considered in the HMR analysis.
The response references AREVA, 2014; NRC, 2011; Entergy, 2001; Entergy, 2013).
The NRC staff reviewed the response and determined the information provided by the licensee was sufficient to address the information need request 5
LIP - Roof Drainage and Sum~ Pum~
The licensee references the response to Information Need No. 3 Discharges for sump pump and discharge locations (Entergy, 2016). Both
Background:
Section 3.1.2.3 of the FHRR (Entergy, sump pumps and roof drains are connected to the storm drain 2015a) (also see AREVA Document No. 32-network which discharges at locations on north and east sides 9231496-000 [AREVA, 2015a]) documents the of the NPIS. The roof drains connect to the storm drain at calculation of water storage and conveyance for locations along the perimeter of the NPIS. The licensee buildings, which considers the geometry of parapet references figures which show the locations of storm drain walls, scuppers, and roof drains at various net~ork outfalls. The outfalls are located away from the locations. Section 3.1.2.1 of the FHRR states that perimeter of the NPIS and at ground elevations lower than that such conveyances "discharge outside of the NPIS" at the perimeter of the NPIS. The licensee stated that even if all but does not describe how or where the flow is of th~ rainf~ll into the NPIS area were discharged to a single discharged. In contrast, the FL0-20 files provided location adjacent to the NPIS, the resulting water elevation lack any refined modeling to consider these features and instead models buildinqs as flat Information Information Need Description
Response
Need No.
elevated grid elements of various heights. Rainfall would not exceed the physical margin available (11.6 to 14.9 ft.
simulated in FL0-20 as occurring on building as described in Information Need No. 4 response).
rooftops appears to be routed to the lowest nearby grid element. Similarly it is not clear where water The licensee's response also clarified and justified the approach from sump pumps in the NPIS is routed to.
used for the routing of building roof drainage and sump pump water discharge in the FL0-20 model to the areas exterior to Request: Clarify how rainfall onto building roofs the NPIS. The licensee stated that drainage from localized and water from sump pumps in the NPIS are points associated with parapet walls, scuppers and roof drains physically routed in the FL0-20 model, and were not specifically modelled. The licensee configured the demonstrate that the model implementation FL0-20 model to discharge all runoff from the NPIS at the accounts for roof runoff and sump pump discharges lowest single grid point near the NPIS and the approach does in a manner consistent with physical reality. If, in not credit the areas within the NPIS that would store runoff reality, rainfall and sump pump discharges are within the NPIS. The licensee stated the FL0-20 analysis used routed to concentrated discharge points, provide a the larger HMR-based PMP relative to the ssPMP for the discussion of how the model simulates localized analysis of LIP flooding of the exterior NPIS areas.
flooding impacts due to concentrated discharge. As necessary, provide sensitivity analysis results that The NRC staff reviewed the response and concluded that the demonstrate the significance of localized f loading information provided by the licensee was sufficient to address impacts from roof and sump pump discharges the information need request.
associated with various operational assumptions.
6 LIP - Site Pumps Operation The licensee response (Entergy, 2016a) reference the
Background:
The FHRR states (Entergy, 201 Sa)
"Equipment Database" and notes the following refers to both that permanent and portable pumps will be OCT basins:
operating after the onset of the LIP event as
- 1. SPMPMP0008A & B - Quality Rated "Important to Safety, described in FHRR Section 2.2.1 as being vulnerable from the LIP event. The details of the Seismic II/I" justification for assuming pumping capacity and
- 2. SPMPMP0014A & B - Quality Rated "Important to Safety, pump initiation time is not clear in the FHRR for the Seismic II/I" COB and the reevaluated hazard. Reasonable justification should be based on pump classification
- 3. SPMPMP0052A & B (Diesels) - Quality Rated "Important to consistent with Nuclear Energy Institute 12-07 (NEI, Safety", Non-Seismic" 2012), and Regulatory Guide 1.102 (NRC, 1976).
"OP-901-521 Rev 316, which implemented the changes for the Request: Provide the safety class (Category 1 FHRR, is provided in Attachment C [in the ERR]. There is a safety related or important to safety) of existina Information Information Need Description
Response
Need No.
OCT A and DCT B pumps (referred to in FHRR 50.59 evaluation and other discussions about classification in Section 2.2.1) for the ultimate heatsink that are the package."
potentially vulnerable to the LIP event, used in the CDB and reevaluated hazard analysis. Provide "Design Change Package 3521 Rev. 4, which implemented the how flood protection barriers (i.e. pumps) are mod[ification] to the procedure] to route the DCT Sumps to classified (incorporated, exterior or temporary) for various locations and installed the Diesel sump pumps, is all credited pumps used in the LIP CDB and the provided in Attachment C [in the ERR]."
reevaluated hazard analyses. If this information is "Design Change Package 3521 Rev. 6, which is the final Rev of not in the OP-901-521 (Entergy, 2014) Severe Weather and Flooding" Off-Normal Procedure, the package, is provided in Attachment C [in the ERR]."
provide in the ERR the operating procedure The response references Entergy, 2000; 2007; 2015b.
documentation used for the COB. Also provide in the ERR a copy of the revision to OP-901-521 The NRG staff reviewed the response and concluded that the described in the FHRR.
information provided by the licensee was sufficient to address the information need request.
The NRG staff notes that subsequent to the submittal of the FHRR, the licensee has also submitted the "Mitigation Strategies Assessment for Flooding Report" (Entergy, 2016b) and a Focused Evaluation for External Flooding for Waterford Steam Electric Station, Unit 3" (Entergy, 2017). Both of these reports discussed pump operations within the NPIS during LIP events.
7 LIP - SumE! PumE! OE!eration AssumE!tions The licensee refers to response to Information Need No. 3 and
Background:
Section 3.1.2.3.3 of the FHRR its associated diagram showing the location of the sump pumps (Entergy, 2015) (also see AREVA Document No.
(Entergy, 2016a).
32-9231496-000 [AREVA, 201x]) summarizes the The licensee states that "the design basis flood is established pumping discharge assumptions used to evaluate for a PMP event draining into the DCT basins. That design LIP (NPIS-lnternal} flooding in the Dry Cooling basis flood is calculated to be less than 1.6 ft of total flooding Tower (OCT) Basins. Per the FHRR, each DCT (flood depth}. See also response to Information Need No. 2."
basin is hydraulically connected to one sump pump, each rated for 350 gallons per minute (gpm), but In order to justify the basis for a 30-min standby time for Motor conservatively reduced to 300 gpm for this Driven Pumps, the licensee refers to Section 5.10 of EC-M99-evaluation. In addition, it is assumed that the site Information Need No.
Information Need Description will face loss of off-site power (LOOP). In order to allow operators time to restart the pumps, the licensee assumes that these sump pumps do not begin operating until 30 minutes (min) after the start of precipitation. As a result, the licensee performed eight pump operational scenarios to calculate ponding depths in the OCT Basins. The most conservative scenario (Base Case) considered includes "One installed sump pump for each OCT basin starting 30-min after the onset of precipitation (300 gpm)".
In deciding on a stand-by time of 30-min, the licensee references Entergy (2001 ). From staff's review of AREVA Document No. 32-9231496-000, Appendix F, Attachment 8.1, (AREVA, 2015a) the design basis requirement for the OCT sump pumps should consider.
To allow time for connecting the pumps to the functioning EOG [emergency diesel generators], a minimum of 30-min would elapse between commencement of the PMP and pump start. (A recommended evaluation would determine the maximum allowable elapsed time between commencement of PMP and pump start in order to establish a time margin for operator action).
In addition, Section 2.3 of the FHRR describes that:
During the design basis PMP event, it is assumed that one motor driven sump pump is engaged within 30 min of the onset of the event, and the diesel powered sump pump Response 010 (Entergy, 2001), which states that "Dry Cooling Tower sump pumps are not available for first 30-min of the PMP in order for operator actions to power the DCT pumps from the diesel-backed busses. This is based on Commitment P4392, which references CR-WF3-2007-1648 and evaluated the 30-min time requirement. CR-WF3-2007-1648 resulted in an Apparent Cause Evaluation and revisions to emergency operating procedures to ensure the remaining sump pump in each cooling tower is operating after the first half hour of the PMP with simultaneous LOOP (current revisions of relevant emergency operating procedures are provided in Attachment D in the ERR and are listed below):
a) OP-902-003 b) OP-902-008 c) OP-902-009 Appendix 20 d) OP-500-002 CR Cabinet Window" Justification for using an ssPMP was provided in response to Information Need No. 4. Please refer to that table entry for details.
The NRC staff reviewed the response and concluded that the information provided by the licensee was sufficient to address the information need request.
The NRC staff notes that after the audit, the licensee submitted the "Mitigation Strategies Assessment for Flooding Report" (Entergy, 2016b) and a Focused Evaluation for External Flooding for Waterford Steam Electric Station, Unit 3" (Entergy, 2017), which further revised operating procedures for the LIP hazard. The NRC staff has completed the MSA review and determine the licensee's submittal was reasonable (NRC, 2017) and the focused evaluation is currently under staff review.
Information Information Need Description
Response
Need No.
is engaged within 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> of the onset of the event.
Additionally, Section 5.1.1 of the FHRR mentions that:
The current design basis at WSES credits one motor driven sump pump activating 30 -
min after the onset of the PMP event, and a diesel powered sump pump activating 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> after the onset of the PMP event.
Based on the information provided in the FHRR and calculation packages, it is not clear whether the design-basis mitigating measures have been established for a LIP-type flood hazard and where the sump pumps discussed are located.
Finally, based on the information provided in Section 5.1.2 of the FHRR, the licensee plans to adopt mitigating measures to ensure that two sump pumps are activated within 30-min after the onset of a LIP event. While the results of the LIP (NPIS-Internal) evaluation demonstrate that such an arrangement would avoid submerging the sump pumps under a site-specific PMP, staff sensitivity analysis indicates that the proposed solution would not prevent sump pump submergence under an HMR-based PMP.
Request: Provide the following information:
a) Discuss the locations, number, and availability of sump pumps servicing the OCT Basins, and provide a diagram which clearly shows the locations of all sump pumps included in the LIP (NPIS-Information Information Need Description
Response
Need No.
Internal) evaluation and the locations of sump pump discharges.
b) Clarify whether the design basis described in Section 2.3 of the FHRR is established for LIP (NPIS-lnternal).
c) Justify the use of 30-min as the stand-by time period between commencement of the PMP and start of pump operation.
d) Provide justification for using a site-specific PMP rather than an HMR-based PMP for the LIP (NPIS-lnternal) evaluation (see Information Need No. 4).
8 Reevaluated and COB Flood Heights The licensee stated in the response (Entergy, 2016a) that "the reevaluated PMF flood height at the WSES site (as opposed to
Background:
Table 4-1 in the FHRR (Entergy, within the river channel on the water side of the levee adjacent 2015) reports the design-basis flood height and to the WSES site) is 20.0 ft. MSL," and "the reevaluated PMF reevaluated flood height for various flood hazard flood height at WSES is bounded by the reevaluated PMF with mechanisms. The design-basis flood height for Dam Failure flood height of 20.6 ft. MSL."
probable maximum flood (PMF) ~n the M~ss~ss~pp~
River is reported as 27.0 ft. MSL in the M1ss1ss1pp1 The licensee stated in the responses that the water surface River, while the design-basis flood height for elevation reported at WSES is the flood level directly applicable Combined Effect Flood is reported as 27.6 ft. MSL to the site. Flood levels in the Mississippi River were reported at WSES. Furthermore, the reevaluated flood for the following reasons:
height is reported as 29.9 ft. MSL in the Mississippi River for PMF, 29.9 ft. MSL in the Mississippi River a) for the PMF on the Mississippi River, only water levels for PMF + Dam Failure, and 20.6 ft. at WSES for in the Mississippi River were reported in the WSES PMF + Dam Failure.
Updated Final Safety Analysis Report (UFSAR)"
Request: Explain why an in-river reevaluated flood Part 1) PMF flood level at WSES height is reported for PMF + Dam Failure flooding The response provided a reevaluated flood height at and for PMF flooding, while a reevaluated flood WSES for PMF flooding the Stillwater value is 20.0 ft.
height at WSES is reported for PMF + Dam Failure MSL. This is bounded by PMF + upstream dam failure flooding, but not for PMF flooding. Describe the flooding at WSES {stillwater of 20.6 ft. MSL).
significance of both design basis and reevaluated
- Section 5 of the FHRR states "Flooding due to Local Intense Precioitation and the CCEF are the onlv flood Information Information Need Description
Response
Need No.
flood heights being reported in the Mississippi River mechanisms which challenge the design basis of the and how these elevations impact the WSES.
WSES site." There is no COB for flooding at WSES for PMF or PMF + Dam Failure.
Part 2) Significance of flood levels being reported in the Mississippi River, UFSAR only reports water levels in Mississippi River.
For the FHRR, the Mississippi River values were reported for comparison to the UFSAR.
Used for assessment of levee failure potential WSES existing procedure for calculating warning time is based on water levels in the Mississippi River.
The response references Entergy, 2013; AREVA 2015c; and AREVA, 2015x.
The NRC staff concluded that the information provided by the licensee was sufficient to address the information need request.
9 Combined Effect Flood-Stead)l-state The licensee's response (Entergy, 2016a) clarified the Assumption controlling combined effect flood, which the licensee refers to as
Background:
The evaluation of the controlling "H.3 - Floods along the shores of Open and Semi-Enclosed combined effect flood uses a steady-state HEC-Bodies of Water". This scenario includes the combination of the RAS [river analysis system] model (Entergy, 2015).
PMSS with coincident wind-wave effects, 25-year flood in the Mississippi River, and levee failure (Alternative 3 of H.3). The Request: Discuss the rationale for utilizing a licensee's consideration of Mississippi River Project Design steady-state flow analysis versus an unsteady-state Flood (PDF) used the USACE PDF flowrate, consistent with analysis in the HEC-RAS model and what other NPPs upstream of the Mississippi River.
differences (in terms of maximum water elevations and velocities) may be expected should an The licensee's rationale for using steady-state simulation for unsteady-state analysis be considered. Describe PMF/Dam Failure was that the historic storm hydrographs on how the use of the steady-state flow approach in the Mississippi River show a wide and flat peak, similar to a the controlling combined effect flood reevaluated steady-state assumption.
flood analysis allows for the estimation of warning time, duration of inundation and time of recession.
Summarize how the values were calculated.
Information Need No.
10 Information Need Description PMF/Dam Failure - Ineffective Flow Areas
Background:
The licensee's evaluation of flooding along streams and rivers and due to upstream dam failures uses ineffective flow areas for regions outside and below the left descending levees of the Mississippi River. While the documentation in the Response The staff performed sensitivity analysis to determine the differences between maximum water elevations using an unsteady-state analysis.
The licensee stated that for warning and inundation times:
Calculation of warning time begins when water level reaches 24 ft. MSL.
Reference was made to the warning time for combined effect Storm 402c Based on the staff's sensitivity analysis and the staff's review of licensee's response to the information need request, the NRC staff concluded that the licensee's rationale for use of a steady state was sufficient to address the information need request.
The licensee did not provide warning, inundation, or recession times during the audit and the licensee indicated that information would be submitted as part of a later assessment in the mitigating strategy assessment or the focused evaluation stage.
The NRC staff notes that subsequent to the audit, the licensee has submitted the "Mitigation Strategies Assessment for Flooding Report" (Entergy, 2016) with the necessary flood duration parameters. The MSA was reviewed by staff, and the associated effects and flood event durations were found to be reasonable and acceptable for use in the MSA and have been appropriately considered in the MSA (NRC, 2017).
The licensee explained that the HEC-RAS configuration included two inter-connected reaches (Entergy, 2106). Right and left areas were defined as if looking downstream.
Ineffective flow areas were used in areas where overtopping of levees would not be expected to occur.
FHRR (Entergy, 2015) and WSES PMF Calculation Package (AREVA Document No. 32-9226996-000)
(AREVA, 2015c) provides a description of the use of ineffective flow areas, no justification was provided. ln addition, since the calibrated and validated models do not overtop the left descending levees, model performance when using these ineffective flow areas was not tested.
Request: Describe and provide justification for how the ineffective flow areas are used in HEC-RAS for steady flow modeling and how the use of this modeling feature affects the conservativeness of the evaluation, especially considering the steady-state flow assumption and the fact that the coupled river system model has not been fully validated. The HEC-RAS reaches are: a) the Mississippi River and the region east of the river's left levee, and b) the floodplain west of the river's right levee. WSES is separated from the Mississippi River by the right levee (with top elevation 29.25 ft MSL). The right and left reaches are interconnected if the right levee is overtopped. Mississippi River water encounters WSES if a right levee failure occurs. The licensee stated that the Mississippi River water elevation cannot significantly exceed the levee top elevation due to expansive spreading that would occur in that event. Two ineffective flow areas along east of the Mississippi River left levee exist.
The licensee conducted sensitivity analysis by removing the ineffective flow areas and yielded the following results:
PMF o
+0.1 ft. in Mississippi River o
-0.5 ft. in Atchafalaya Floodplain PMF + Dam Failure o
+0.3 ft. in Miss. R. (31.2 ft. MSL) o
-0.4 ft. in Atchafalaya Floodplain The calibration and validation runs did not overtop the levees.
Use of ineffective flow areas was judged to be conservative.
The licensee found that excluding these areas (i.e. treating them as ineffective flow areas) resulted in reduced WSES flood elevations.
The licensee's sensitivity analysis considered the combination of a reduced weir coefficient (0.4) with the removal of the ineffective flow areas. The sensitivity demonstrated by the licensee shows little change in the floodplain. The staff also performed sensitivity runs with a quasi-steady state model.
Based on the review of the licensee's response and the staff's sensitivity analysis, the NRC staff considers the ineffective flow area assumption to be acceptable for determining flooding elevation and velocity and concluded that the information
Information Information Need Description
Response
Need No.
provided by the licensee was sufficient to address the information need request.
11 PMF/Dam Failure - Lateral Structure Weir The licensee's response stated (Entergy, 2016) that "The Coefficient selection of a weir coefficient of 2.6 is supported by the Brunner literature (Brunner, 2014)." The licensee provided in the
Background:
The HEC-RAS model used to response a table from the literature. The licensee stated that evaluate flooding along streams and rivers, and the levee was over 3 ft. high and, according to the table upstream dam failures was calibrated using provided, the range of weir coefficient for such leve~s is 1 :5. to historical observation data and validated using the 2.6. Thus, the licensee stated that the selected weir coeff1c1ent USAGE PDF, both of which represent events which of 2.6 was within the expected range based on the literature.
did not overtop levees, meaning that these model features were not tested, and the ability of the final The staff performed a sensitivity analysis _using ~ ~teady state model to predict flow distribution between the model to test a reduction of the lateral weir coeff1c1ent.
Mississippi River and Atchafalaya River floodplain is Based on the staff's sensitivity analysis and the staff's review of largely unknown (see FHRR and WSES PMF Calculation Package [AREVA Document No. 32-licensee's response to the information need request, the NRC 9226996-000]) (Entergy, 2015; AREVA, 2015c). In staff concluded that the information provided by the licensee particular, as a major driver of flo~ ~istributio~ in was sufficient to address the information need request.
the model, the selected weir coeff1c1ent value 1s unverified and is based on typical inline broad-crested weir coefficient values of 2.6 to 3.1.
Based on the HEC-RAS simulation for flooding in streams and rivers, the selected upstream flows entering the Mississippi and Atchafalaya Rivers at River Station (RS) 320 are 6,800,000 cubic feet per second (ft3/s) and 875,000 ft3/s, respectively.
Downstream at RS 130 (WSES location), the majority of the flow has been routed to the Atchafalaya River, with 5,875,000 ft3/s in the Atchafalaya River and 1,800,000 ft3/s in the Mississippi River. Based on these results, significant flow is routed from the Mis~issippi Ri~er to the Atchafalava River via overtopoina of the riaht Information Information Need Description
Response
Need No.
descending levee (modeled as a Lateral Structure in HEC-RAS).
Although presented in the context of the recently released 1-D/2-D version of HEC-RAS, Brunner (2014) discusses a common issue associated with modeling flow transfer from a river to a floodplain in which too much flow is transferred when using typical inline weir coefficients. As a solution, Brunner (2014) provides guidelines for weir coefficient values for various lateral weir scenarios, including modeling natural high ground barriers using weir coefficients of 0.5 to 1.0 and modeling overland flow escaping a main river using weir coefficients of 0.2 to 0.5, much lower than the selected value of 2.6. Based on the discussion provided in this literature and the fact that significant flow transfer to the floodplain occurs, the use of lower weir coefficients may be justified.
Request: Discuss the rationale for selecting a weir coefficient of 2.6 and the potential for this value to inadequately represent flow transfer to the floodplain. Considering the guidance presented in the Brunner (2014) literature, describe whether lower weir coefficients may be more appropriate, especially considering the steady-state flow assumption and the fact that the coupled river system model has not been fully validated.
12 Dam Failure - Peak Flow Attenuation The licensee stated in their response (Entergy, 2016) the use of
Background:
The evaluation of flooding due to peak flow attenuation for dam failure flooding evaluation reflects upstream dam failures assumes that attenuation NRC's JLD-ISG-2013-01 (NRC, 2013) for dam failure. The occurs between the most-downstream dam failed licensee's conservatism is present through the assumptions and the WSES location (see FHRR and WSES used to simulate two upstream "hypothetical" dams and the PMF Calculation Package (AREVA Document No.
empirical breach outflow assumed for these dams. The Information Information Need Description
Response
Need No.
32-9226996-000)) (Entergy, 2015c). The peak licensee also stated that historical dam failure characteristics breach flows calculated for the Arkansas-White-Red support greater attenuation associated with wider floodplains.
Region and Lower Mississippi Region hypothetical Part of the staff's initial concern was that historical dam failure dams are roughly 11.3 million ft3/s and 5.5 million attenuation had not been documented for attenuation ft3/s, respectively. After accounting for attenuation percentages as low as those used for WSES. The rationale using the U.S. Bureau of Reclamation (USBR) described by the licensee appears to make sense, though method, the peak breach flows are 34,000 ft3/s (0.3 attenuation of 0.3% of peak flow was used for the Arkansas-percent of the total flow) and 280,000 ft3/s (5.1 White-Red Region. The lowest value reported in the USBR percent of the total flow), respectively. These literature used to derive the equation is around 3% at a distance hypothetical dam failures are assumed to occur due of about 70 miles downstream of the dam or the location where to overtopping coincident with the PMF.
the peak discharge was recorded. The licensee response Consequently, the combined attenuated peak discusses the larger distances between the dams and the breach flows are added to the PMF flows as a WSES site than those discussed in the USBR literature.
steady-state flow for simulating dam failure flooding impacts.
The licensee presented a literature review of dam breach flow attenuation and concluded that the use of the USBR equation is Request: Justify the application of the USBR appropriate. Guidance in JLD-ISG-2013-01 (NRG, 2013) states attenuation method for peak flow attenuation, and "Regression equations for attenuation provided in USBR (1982) describe how the historical data used to develop the may be used, but should be tested against available models USBR empirical equation compares with the and/or studies to justify their applicability to the river/floodplain postulated dam failure being simulated.
system." The licensee did not provide reference to previous use of this method for this river/floodplain system. The staff reviewed additional literature, which detailed that significant attenuation could reasonably occur at the site.
Based on the staff's independent literature review and the staff's review of licensee's response to the information need request, the NRG staff concluded that the information provided by the licensee was sufficient to address the information need request.
13 Dam Failure - Model lnstabilit~
The licensee stated (Entergy, 2016) that the HEC-RAS model
Background:
Section 3.3.2 of the FHRR (Entergy, for the site is steady state with a split flow between the 2015a) (also see WSES PMF Calculation Package, Mississippi and Atchafalaya rivers.
AREVA Document No. 32-9226996-000 [Entergy, The licensee acknowledged the instability issue and conducted 2015c]) describes the dam failure flooding results sensitivity analysis to demonstrate that the results presented and indicates that, initially, dam failure peak breach Information Information Need Description
Response
Need No.
flow was added to the upstream end of the (from an unstable model) were more conservative than those Mississippi River in HEC-RAS; however, the displaying more stability {i.e., the floodplain peak WSE was additional flow resulted in HEC-RAS model higher/more conservative). The licensee's results are similar to instabilities {including decreasing the WSE in the those obtained by staff. The sensitivity of the model within the Mississippi River despite increases in flow). Since Atchafalaya Floodplain is insignificant relative to the noted the model is run in a steady-state mode, the instability..
increased flow added to the upstream boundary of Mississippi River is routed in the model to the The licensee references USAGE, 201 O and NRC, 2013 in the Atchafalaya River, which does not seem to be response.
technically reasonable. The licensee's solution was to instead add the dam failure flow to the upstream end of the Atchafalaya River, which results in a minor increase in elevation within the Atchafalaya River and no change in the Mississippi River.
Based on the licensee's unsuccessful attempt to route the dam failure flow through the upstream end of the Mississippi River, it would appear that there may be an issue with the way in which flow is routed between the two river systems {see Information Need No.10). Sensitivity analysis conducted by NRC staff using a lower lateral weir coefficient value was able to avoid the model instability reported by the licensee.
Request: Describe the factors which may contribute to the model instability observed when increasing flow at the upstream end of the Mississippi River, and justify the use of a model which demonstrates instability despite relatively minor changes in boundary conditions. Provide justification for the selected approach to routing dam breach flows, which resulted in no change in elevations in the Mississippi River at WSES despite an over 4 percent increase in flow that should have entered the system. Provide alternative modeling or enQineerinQ calculations which more Information Information Need Description
Response
Need No.
appropriately demonstrate the flooding impacts including WSE, velocities, and timing issues, associated with the increased flow from dam failure.
14 Combined Effects - Bounding Storm Selection The licensee's response (Entergy, 2016a) referenced the
Background:
According to Section 3.9.4 of the response to Information Need No. 4. The licensee states in the response that "Results for Storm 302 and Storm 402c are FHRR (Entergy, 2015a), "the Controlling Combined discussed in the FHRR to illustrate the steps used in the HHA Effect Flood (CCEF) scenario is considered to be process."
the result of H.3, Storm 402c." However, review of the results for the Storm 302 evaluations indicates The licensee references AREVA Document Nos. 32-9227036-Storm 302 bounds Storm 402c in terms of 000 (AREVA, 2015b) and 32-9227002-000 (AREVA, 2015e).
maximum WSE, maximum flow depth, maximum Storm 302 (offshore decay, no post-landfall, onshore decay) velocity, and time to maximum flow depth (FHRR, flood hazards indicated flood impacts to SSCs. Storm 402c Table 3-29).
(offshore and post landfall, onshore decay) was examined as HHA refinement to Storm 302. The licensee states that rates of Request: Explain why the results from the Storm decay are provided in AREVA Document Nos. 32-9227036-000 402c evaluation are used for the Controlling and 32-9227002-000. The rates are stated as being evaluated Combined Effect Flood, considering Storm 302 against historical data and as being more conservative than produces more severe flooding impacts.
published rates. The offshore decay rate was based on historical data.
The HHA approach was used by the licensee to evaluate combined effects floods at WSES as outlined in NU REG/CR-7046 (NRC, 2011)
Storm 302 considered offshore decay, onshore decay of PMH, indicating flood impacts to SSCs.
Storm 402c considered offshore decay, post landfall, and onshore decay that is used for controlling combined effect f load
- The simulations were performed in a step-wise manner to assess the sensitivity of the resulting surge elevations at the Waterford site to hurricane intensity decay.
The NRC staff reviewed the information in response to licensee's allowance for wind intensity decay and concluded Information Information Need Description Need No.
Response
that the information provided was sufficient to resolve the information need request. However, the staff issued a follow-up information need regarding Storm 401 a and why that storm was not considered after reviewing the licensee's response (see Information Need No. 19).
15 Combined Effects - Outflow Elements The licensee's response (Entergy, 2016a) stated that with
Background:
As described in Section 3.9.3.3 of the regard to the FL0-2D outflow hydrographs, even though the FHRR (Entergy, 2015a) (also see Combined Effects FL0-2D hydrographs start as a dry site, they reach maximum Calculation Package, AREVA Document No. 32-WSE at site of 24.0 ft. MSL prior to failure of levee. The 9227036-000 AREVA, 2015b]), FL0-2D outflow hydrograph started at 1.4 ft. MSL to maintain model stability.
elements were modeled as stage control elements The staff performed a sensitivity analysis to determine the by specifying time-stage relationships along the model computational boundary. One curve was impact of the time-stage relationships on the peak WSE.
established for outflow elements along the In addition to the staff's sensitivity analysis, the staff reviewed Mississippi River, with a different curve used along the remaining model boundary, representing the the licensee's response and concluded the information provided Atchafalaya floodplain.
by the licensee was sufficient to resolve the information need request.
Based on review of AREVA Document No. 32-9227036-000 (AREVA, 2015b), Figure 41, the time-stage relationships used in FL0-2D do not match the output hydrographs from the PMSS with 25-year river flood simulations. Most importantly, based on the curves used in FL0-2D and review of the FLO-2D time-depth output, the WSES site is dry when water begins to overtop the Mississippi River right descending levee. However, Figure 41 shows water elevation in excess of site grade for several hours prior to the levee being overtopped.
Request: Provide justification for selecting the time-stage relationships used in the final FL0-2D run that starts with a dry site, despite those curves not matching with the PMSS with 25-year river flood simulation results that shows the site to be wet prior Information Information Need Description
Response
Need No.
to overtopping. As a part of the response, consider impacts on both maximum WSE and associated effects (e.g., velocity, inundation time, etc.}. If necessary, provide a sensitivity analysis to demonstrate the relative impacts of changing the time-stage curves set for FL0-20 stage control elements.
16 Combined Effects - Levee Failure Trigger The licensee's response (Entergy, 2016a) refers to responses to Elevation Information Needs No. 14 and 15 regarding use of Storm 402c.
Background:
As described in Section 6.3.3.1 of The licensee indicated that the maximum stillwater elevation in Combined Effects Calculation Package (AREVA the Mississippi River based on ADCIRC+SWAN s.im.ulation_s for Document No. 32-9227036-000} (AREVA, 2015b},
Storm 402c + 25-year flood is 29.5 ft. MSL. Specifying a higher the simulation of Combined Effects scenario H.3, levee prescribed failure elevation is not realistic. The licensee Storm 402c uses a levee prescribed failure stated the failure elevation of the levee was set to 29.4 ft. MSL elevation of 29.4 ft. MSL, which is 0.5 ft. below the for Storm 402c and was based on the maximum WSE in the prescribed failure elevation used for scenario H.3, Mississippi River for this storm scenario. The l 1i 1censee st~ted in Storm 302 (29.9 ft. MSL} and 0.6 ft below the l~ve~
the response to Information Need No. 15, that the prescribed crest elevation of 28.6 ft. NAVD88. A change in this levee failure elevation of 29.4 ft. MSL corresponds to a failure parameter could have impacts on flooding at Mississippi River water surface elevation of 29._5 ft. MSL" or 0.1 WSES.
ft higher than the specified levee breach elevation and 0.5 ft.
Request: Provide justification for selecting a levee below the top of the levee elevation of 29.9 ft. MSL. The licensee stated in the response that "(h]ydrologic failure of the prescribed failure elevation of 29.4 ft MSL for Storm levees were conservatively assumed to result from wave 402c as opposed to the higher elevation used for overtopping for Storm 402c even though the levees are not Storm 302 (29.9 ft. MSL). As a part of the overtopped by the Stillwater flood."
response, consider impacts on bot.h ~aximun: WSE and associated effects (e.g., velocity, inundation The NRC staff reviewed the response and concluded the time, etc.}. If necessary, provide sensitivity information provided was sufficient to resolve the information analyses to demonstrate the relative impacts of need request.
increasing the levee prescribed failure elevation.
Information Information Need Description
Response
Need No.
17 Combined Effects - Manning's Roughness The licensee's response (Entergy, 2016a) stated that the Coefficient (n) selected Manning's n values used in the FL0-2D modeling
Background:
Comparison of Table 3 in WSES LIP (AREVA, 2015b; Table 3) were based on recommended Calculation Package (AREVA Document No. 32-Manning's n values for various land cover types in the FL0-2D 9226993-000) (AREVA, 2014) and Table 1 in Reference Manual and in the Open-Channel hydraulics text Combined Effects Calculation Package (AREVA book by Chow and upon engineering judgement. Depth Document No. 32-9227036-000) (AREVA, 2015b) variable Manning's Roughness Coefficients were used in the indicates that the same Manning's roughness n FL0-2D flood simulations. The licensee stated in the response coefficients were used for each land cover type (Entergy, 2016a) that Manning's roughness coefficients are a considered. However, review of the FL0-2D function of flow depth and that shallow flows (generally less than Reference Manual suggests that the selected 0.5 ft.) require high coefficients to account for increased Manning's roughness coefficients lie at the lower resistance to relatively greater surface roughness conditions.
end of the recommended range for overland flow.
The Manning's roughness was prescribed for flow depths less In the absence of any calibration data, a than 0.2 ft. and half that value for flow depths between 0.2 ft.
conservative approach is warranted, and, as such, and 0.5 ft. The Manning's roughness coefficient was set to a staff requests that model sensitivity to the selection deep flow value (flow depths of 3 ft and greater). The of Manning's n values be tested. The staff's Manning's roughness coefficient varied for flood depths experiences with other sites and sensitivity runs between 0.5 ft. and 3.0 ft. according to an exponential function conducted for the Waterford site indicate that use of within FL0-2D. The licensee stated that for Storm 402c, the a higher Manning's n value for this modeling will maximum flood depths ranged from 7.5 to 8.9 ft. At these flood result in a higher predicted WSE.
depths, the FL0-2D model would set the Manning's roughness coefficient to the licensee's specified deep flow value.
Request: Provide justification for selecting the Manning's n values used in the FL0-2D modelling.
If necessary, provide sensitivity analyses for using In the response the licensee discussed the reasonable ranges Manning's n values adjusted to the upper end of the of Manning's roughness coefficient as reported in the literature, ranges recommended in the FL0-2D Reference as recommended for FL0-2D models and other models, and as Manual. As a part of the response, consider influenced by whether the flow analysis was one-or two-impacts on both predicted maximum WSE and dimensional. The licensee stated that the values used were associated effects (e.g., velocity, inundation time, appropriate.
etc.) at the WSES site.
The licensee did not provide sensitivity analysis, but the staff determined that relatively minor changes resulted when varying the Manning's n values during its own sensitivity modeling runs.
Information Information Need Description Need No.
Response
The response references AREVA, 2015b; FL0-2D, 2012; and Chow, 1959.
The staff reviewed the response and concluded that the information provided, in addition to the results of staff's sensitivity runs, resolved the information need request.
18 Storm Surge Anal)lsis - Datum Conversion The licensee confirmed (Entergy, 2016a) that to convert from
Background:
The FHRR (Entergy, 21 Sa) contains NAVD88 to MSL, + 1.43 ft. is added. The licensee stated that two different references related to conversion of LMSL is not the same as Plant Datum (MSL). The licensee elevations in the NAVD88 and MSL datum.
stated that the only use of the LMSL to NAVD88 was for the AWL calculation. The licensee stated in the response that "the
- a. FHRR Section 1.5 states "To convert average LMSL adjustment for the South Louisiana Region was elevations from the North American Vertical based on the lnteragency Performance Task Force report Datum of 1988 (NAVD88)-2004.65 to Mean (USAGE, 2006; also see AREVA, 201 Sb)". The conversion of Sea Level (MSL) (Plant Datum), 1.43 ft is LMSL to NAVD88 is not the same conversion used to convert added to the NAVD88-2004.65 elevation from MSL to NAVD88.
(see Appendix A)". Appendix A contains The licensee references AREVA 2015b; AREVA, 2015f; and additional information on the NAVD88 and MSL conversion (Appendix includes the 1.43 UASCE, 2006 in this response.
ft value).
The NRC staff reviewed the response and concluded it is
- b. FHRR Section 3.4.4.2.1 provides the conversion between local mean seal level sufficient to resolve the information need request.
(LMSL) and NAVD88: 'The average LMSL to NAVD88-2004.65 adjustment for the South Louisiana region is calculated to be 0.135m (0.44 ft)." This conversion is applied in the Antecedent Water Level calculation.
Request: Provide additional explanation of when or how each NAVD88 to MSL conversion was applied in the FHRR analyses.
19 Storm Surge Anal)lsis - Storm Selection The licensee stated (Entergy, 2016a) that although Storm 401 a results in a higher Mississippi River water level than Storm 402c, FL0-2D simulations for the levee breach analysis for Information Information Need Description
Response
Need No.
Background:
FHRR Section 3.9.3.3 (Alternative 3, Storm 401 a were not performed. The licensee determined that Part C) discusses the combined effects analysis for Storm 402c would produce higher peak WSEs at the site. The storm surge with the Probable Maximum Hurricane, licensee references the combined effects calculation (AREVA, 25-year river flow, Antecedent Water Level, and 2015b) to support this determination. In the response, the levee failure (Entergy, 2015a).
licensee included Table 19-1, which is an update of FHRR Table 4-1. The licensee's Table 19-1 in the response shows
- a. The discussion states "Levee failure results based on other storm simulations that included levee simulations using FL0-20 were breach analysis. The table focuses on the differential between performed for Storm 302 and Storm the Mississippi River and site water levels. Regarding the PMF 402c." FHRR Table 3-35 presents on the Mississippi River mechanism at the Waterford site, the ADCIRC+SWAN results for design-basis flood height was modified to "No flooding" and the representative storms including reevaluated flood height was stated as 20.0 ft. MSL at the Storms 302 and 402c. Storms 302 Waterford site. Regarding the mechanism description of the and 402c have storm tracks that Controlling Combined Flood Scenario, the licensee's update of head due north and produce the table included the following additional description: "PMSS maximum surge at the site (before from Gulf of Mexico with coincident wind-wave effects, 25-year levee failure analysis). FHRR Table flood in the Mississippi River, and levee failure." The original 4-1 presents the results, including FHRR Table 4-1 included a note that the LIP hazard levels was levee failure analysis, from Storm based on an assumed pumping criteria described in FHRR 402c as the Controlling Combined Section 5; in the revised table the reference was not included.
Effect Flood Scenario in the The relevant update in the information need response (Table Reevaluated Flood Height column.
19-1) is the explicit statement of the components of the controlling combined flood scenario.
- b. Table 3-35 also includes results from Storm 401a, which based on Table The licensee stated that "because the flood response at the 3-35, applies the same PMH forcing sites, after levee breach, is more dependent on the absolute as Storm 402c other than landfall differential head between the initial water elevation in the location and track angle (bearing).
M[ississippi] R[iver] and at the site than upon the actual Storm 401a features a track that elevation in the M[ississippi] R[iver]". The licensee illustrated moves the storm in a northwesterly the trend of the head differential between the Mississippi River direction (-40 degrees from North).
level and the site versus the change in elevation at site after Table 3-35 indicates Storm 401 a breach.
features higher maximum water levels in the Mississippi River near The staff reviewed the explanation provided by the licensee, the Waterford site than Storm 402c which stated that both the water level in the Mississippi River and the water level at the site at time of breach are important.
Information Information Need Description
Response
Need No.
31.8 ft MSL for Storm 401 a versus The licensee is deferring associated effects and flood event 29.5 ft MSL for Storm 402c).
duration parameters to the MSA stage.
Because the river water levels will propagate The response references AREVA, 201 Sb and Entergy, 201 Sa.
towards the site during the levee breach analysis (as input into the FL0-20 model), the staff notes The staff reviewed the licensee's response and concluded that that Storm 401 a forcing could potentially produce the information provided was sufficient to resolve the higher maximum water levels at the site than Storm information need request.
402c under a levee failure scenario.
Request: Provide discussion of why FL0-20 simulations for the levee breach analysis were not performed for Storm 401 a, a storm that resulted in higher Mississippi River water levels than Storm 402c.
20 Flood Event Timing Parameters The licensee requested to defer providing this information until
Background:
FHRR Section 3.1.2 (Entergy, 201 Sa) the MSA stage of the review.
indicated that the LIP internal to the NPIS was not The NRC staff notes that subsequent to the audit, the licensee bounded by the COB. The FHRR does not describe submitted the "Mitigation Strategies Assessment for Flooding the flood event timing parameters (warning time, Report" (Entergy, 2016) with flood duration parameters. The preparation time, flood duration and recession MSA was reviewed by staff and the associated effects and flood time). Warning time and preparation time is not event durations were found to be reasonable and acceptable for clearly stated for the current licensing basis. The use in the MSA, and have been appropriately considered in the staff noted that some of this information may be MSA (NRC, 2017).
provided in the OP-901-521 (Entergy, 2014)
"Severe Weather and Flooding" prior to it revision as described in the FHRR. The staff also noted that warning times are utilized in the Operational Decision Making Issue implementation action plan.
These procedures are mentioned in Section 5.1.2 of the FHRR as interim actions which are not equivalent to those under the current licensing basis (Enterav, 201 Sa).
Information Need No.
21 22 Information Need Description Request: Provide flood event duration parameters associated with the LIP and combined event, or describe when the parameters will be provided.
Local Intense Precipitation - Site Specific PMP The staff requests the following files be submitted on the docket for use in the staff assessment:
- 1. AWA SSPMP Main Report for Waterford Steam Electric Station This request is for the complete AW A ssPMP report in Adobe pdf format, including all appendices.
- 2. AWA ssPMP LIP Calculation Package for Waterford Nuclear Generating Station This request is for the complete calculation package for site-specific LIP calculations, including all appendices.
Local Intense Precipitation - Site Specific PMP The staff requests the following files be provided on a DVD for staff review as part of the audit:
1. The complete storm analysis information for LIP ssPMP. Provide the analysis information for all short list storms that were used for LIP ssPMP calculations (such as those reported in the previous AWA reports).
The detailed storm analysis information should include:
Storm spreadsheet Moisture inflow map Response The NRC staff determined that a detailed review of the licensee's site specific PMP review is not needed, and thus Waterford was informed they did not need to respond to this information need request.
The NRC staff determined that a detailed review of the licensee's site specific PMP review is not needed.
Information Information Need Description
Response
Need No.
- Depth-area-duration values and chart
- Storm cumulative mass curve chart
- Total storm isohyetal analysis map HYSPLIT trajectory map In-place storm representative dew point (or sea surface temperature) analysis map
- 2. AWA Initial Storm Long List In addition to the final storm short list, the licensee should also submit an Excel file documenting the complete initial long list storms that have been considered during the development of the LIP ssPMP. If a storm is excluded from the final short list, a brief justification should be provided. In addition, documentation should be provided to identify which long list storms have been previously evaluated by AWA and which have been newly evaluated as a part of the ssPMP study. If a subset of long list storms were included/excluded based on previous Federal Energy Regulatory Commission BOC or state PMP study conclusions, the exact reference should be clearly stated.
- 3. AWA Observed Hourly Dew Point Data Sheet For each short list storm, the licensee should submit an individual spread sheet documenting the hourly dew point data that were used for storm representative dew point selection (page 8, Section Storm Adjustments, item 2e in AWA PMP Development Workflow Description Information Information Need Description
Response
Need No.
submitted to NRG on May 7\\ 2015). If publicly-accessible dew point datum were used (e.g., NGOC ISO), the unique station identifier (e.g., USAF, WBAN, and/or ICAO) and the starting/ending dew point date and hour (used for the calculation of average 6-,
12-, or 24-hour dew points) should be clearly specified. If the selection of storm representative dew point location deviated significantly from the HYSPLIT trajectories, detailed meteorological reasoning should be provided. If sea surface temperature is used as a surrogate of surface dew point observation, the sea surface temperature observation should be provided.
- 4. AWA Calculation Sheet of 100-year Dew Point Climatology At locations where the 100-year dew points were derived from dew point climatology maps (i.e.,
moisture source before/after storm transposition),
the dew point bias resulting from map smoothing should be examined. Bias is defined as the difference between the nearest gauge estimates to the smoothed map values. If the bias is sufficiently large (e.g., negative 2 F leading to 8% reduction of maximized precipitation depth), the calculation sheet of 100-year dew point at the selected gauge should be provided for review.
Sources:
AREVA, 2014, "Waterford Steam Electric Station Flooding Hazard Re-evaluation - Local Intense Precipitation," Rev 000, AREVA Document No.
32-9226993-000 (Entergy Nuclear WF3-CS-15-00011 Rev 0, EC No. 59098, Vendor Document No. 32-9226993-000), Signed December 16, 2014. Posted to Curtiss-Wright ERR as "LIP External to Nuclear Plant Island Structure" on September 14, 2015.
AREVA, 2015a, 'Waterford Steam Electric Station Flooding Hazard Re-evaluation - Nuclear Power Island Structure Local Intense Precipitation,"
Rev 000, AREVA Document No. 32-9231496-000, Entergy Nuclear signed May 1, 2015. Included on hard drive submitted to NRC on September 4, 2015.
AREVA, 2015b, "Waterford Steam Electric Station Flooding Hazard Re-evaluation -Combined Effects," Rev 000, AREVA Document No. 51-9227036-000 (Entergy Nuclear WF3-CS-15-00017 Rev 0, EC No. 59098, Vendor Document No. 32-9227036-000), Signed June 8, 2015. Posted to Curtiss-Wright ERR as "Combined Effects" on September 14, 2015.
AREVA, 2015c, "Waterford Steam Electric Station Flooding Hazard Re-evaluation Probable Maximum Flood," Rev 000, AREVA Document No.
32-9226996-000 (Entergy Nuclear WF3-CS-15-00012 Rev 0, EC No. 59098, Vendor Document No. 32-9226996-000), Rev 000, Signed August 13, 2015. Posted to Curtiss-Wright ERR as "Probable Maximum Flood" on September 14, 2015.
AREVA, 2015d, "Waterford Steam Electric Station Flooding Hazard Re-evaluation - Dam Failure," Rev 000, AREVA Document No. 32-9226999-000 (Entergy Nuclear WF3-CS-15-00013 Rev 0, EC No. 59098), Vendor Document No. 32-9226999-000), 2015, Signed January 22, 2015. Posted to Curtiss-Wright ERR as "Dam Failure" on September 14, 2015.
AREVA, 2015e, "Waterford Steam Electric Station Flooding Hazard Re-evaluation - Probable Maximum Hurricane," Rev 000, AREVA Document No. 32-9227002-000 (Entergy Nuclear WF3-CS-15-00014 Rev 0, EC No. 59098, Vendor Document No. 32-9227002-000), Signed August 13, 2015. Posted to Curtiss-Wright ERR as "Probable Maximum Hurricane" on September 14, 2015.
AREVA, 2015f, "Waterford Steam Electric Station Flooding Hazard Re-evaluation - Probable Maximum Storm Surge," Rev 000, AREVA Document No. 32-9227005-000 (Entergy Nuclear WF3-CS-15-00015 Rev 0, EC No. 59098, Vendor Document No. 32-9227005-000)," Signed August 13, 2015. Posted to Curtiss-Wright ERR as "Probable Maximum Storm Surge" on September 14, 2015.
Brunner, 2014, Gary W. Brunner, "Combined 1 D and 2D Modeling with HEC-RAS," Hydrologic Engineering Center (HEC), October, 2014, Available at http://www.hec.usace.army.mil/misc/files/ras/Combined_ 1 D_and_2D_Modeling_with_HEC-RAS.pdf and http://hecras mod el. b logs pot.com/2013/12/lateral-structu re-coefficients. html.
Chow, 1959, "Open Channel hydraulics", McGraw Hill Book Company, Inc.
Entergy Operations, Inc. (Entergy), 1992a, Waterford Steam Electric Station Drawing No. G-874 S01, "Fuel Handling Building Plan El. -34.75 =
SH. 1 Plumbing & Drainage," March 10, 1992.
Entergy, 1992b, Waterford Steam Electric Station Drawing No. G-886, "Reactor Building Plan El 21.00 Plumbing & Drainage," February 6, 1992.
Entergy, 1998, Waterford Steam Electric Station Document No. G-886 "DRN No. M9702663," Page 2 of 2, November 18, 1998.
Entergy, 2012, Waterford Steam Electric Station Drawing No. G-492 "General Plant Area Grading & Drainage-Plan," December 5, 2012.
Entergy, 2000, "Route DCT Sumps Discharge to Circulating Water System," DCP-3521, Revision 4, Signed January 26, 2000.
Entergy, 2001 a, AREVA Document No. 38-9243507-000, Calculation EM-M99-01 O Revision 0-2, Signed August 24, 2001.
Entergy, 2001 b. Waterford Steam Electric Station Drawing No. G-210, "General Arrangement Cooling Tower Plan," April 16, 2001.
Entergy, 2007, "Route OCT Sumps Discharge to Circulating Water System," DCP3521, Signed June 6, 2007.
Entergy, 2013, Final Safety Analysis Report-Revision 307, Letter dated July 11, 2013, ADAMS Accession No. ML13218A409 (Non-Public).
Entergy, 2014, WSES Procedure Number OP-901-521, Revision 315, "Severe Weather and Flooding," See AREVA Document No. 38-9243507-000.
Entergy, 2015a, "Watertord Steam Electric Station Flooding Hazard Re-evaluation Report," Enclosure to Letter from Michael R. Chisum to the NRG Document Control Desk,
Subject:
"Flood Hazard Reevaluation Report Waterford Steam Electric Station, Unit 3 (Waterford 3)", July 21, 2015, ADAMS Accession No. ML15204A344.
Entergy 2015b, WSES Procedure Number OP-901-521, Revision 316, "Severe Weather and Flooding," Off Normal Procedure Severe Weather and Flooding, July 2, 2015.
Entergy, 2016a, "Waterford Steam Electric Station Flood Re-evaluation Audit - March, 2016". Posted to Curtiss-Wright ERR as "WSES Audit Slides 3-3-16" on March 3, 2016.
Entergy, 2016b, "Mitigating Strategies Assessment for Flooding Report," Enclosure to Letter from Michael R. Chisum, Vice President Operations Waterford 3, to NRG Document Control Desk,
Subject:
Mitigating Strategies Assessment (MSA) Report for Flooding Hazard, Waterford Steam Electric Station, Unit 3 (Waterford 3), November 14, 2016, ADAMS Accession No. ML16319A089 (Public).
Entergy, 2017, "2017 Focused Evaluation for External Flooding at Waterford Steam Electric Station 3," Enclosure to Letter from of Michael R.
Chisum, Site Vice President Waterford 3, to NRG Document Control Desk,
Subject:
Focused Evaluation of External Flooding for Waterford Steam Electric Station, Unit 3 (Waterford 3), Dated May 17, 2017, ADAMS Accession No. ML17137A355 (Public).
FL0-20, 2012, FL0-2D Professional Version References Manual, FL0-2D Software Inc., Nutrioso, Arizona, 2012.
Nuclear Energy Institute (NEI), 2012, "Guidelines for Performing Verification Walkdowns of Plant Flood Protection Features," Enclosure to Letter from James H. Riley, Principal Engineer, Nuclear Generation Division, NEI, to NRG Document Control Desk, Subject Submittal of NEI 12-07, Revision 0, Guidelines for Performing Verification Walkdowns of Plant Flood Protection Features, May 21, 2012, ADAMS Accession No. ML121440522 (Public).
U.S. Nuclear Regulatory Commission (NRG), 1976, "Flood Protection for Nuclear Power Plants," Regulatory Guide 1.102, Revision 1, September 1976, Reviewed September 2014, ADAMS Accession No. ML003740308 (Public).
NRG, 2011, "Design-Basis Flood Estimation for Site Characterization at Nuclear Power Plants in the United State of America," NUREG/CR-7046, November 2011, ADAMS Accession No. ML11321A195 (Public).
NRG, 2012, Letter from Michael R. Johnson, Director, Office of New Reactors, to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status,
Subject:
"Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident," March 12, 2012, ADAMS Accession No. ML12056A046 (Public).
NRG, 2013, "Guidance For Assessment of Flooding Hazards Due to Dam Failure," Japan Lessons-Learned Project Directorate, Interim Staff Guidance JLD-ISG-2013-01, Revision 0, July 29, 2013, ADAMS Accession No. ML13151A153 (Public).
NRG, 2017, "Staff Assessment Related to the Mitigation Strategies for Waterford Steam Electric Station, Unit 3 As a Result of the Reevaluated Flooding Hazards Report Near-Term Task Force Recommendation 2.1 - Flooding," Enclosure to Letter from Robert Bernardo, Project Manager, to Site Vice President, Entergy Operations, Inc.,
Subject:
Waterford Steam Electric Station, Unit 3 - Flood Hazard Mitigation Strategies Assessment, February 27, 2017, ADAMS Accession No. ML17023A282 (Public).
U.S. Bureau of Reclamation (USBR), 1982, "Guidelines for Defining Inundated Areas Downstream from Bureau of Reclamation Dams," Reclamation Planning Instruction No. 82-11, June 15, 1982.
USBR, 1988, "Downstream Hazard Classification Guidelines", ACER Technical Memorandum No. 11, U.S. Department of the Interior, Denver, CO., December, 1988.
USAGE (U.S. Army Corps of Engineers), 2010, HEC-RAS River Analysis System, Hydraulic Reference Manual, Report No. CPD-69, Version 4.1, USAGE Hydrologic Engineering Center, January 2010. Available online at http://www.hec.usace.army.mil/software/hec-ras/.
USAGE, 2006, Performance Evaluation of the New Orleans and Southeast Louisiana Hurricane Protection System, Draft Final Report of the lnteragency Performance Evaluation Task Force, June 2006.
ATTACHMENT 3 Waterford Steam Electric Station, Unit 3 Tables and Figures Table 1. Summary of Results of FL0-20 Levee Failure Analysis in WSES Combined Effect Calculation (adapted from Table 19-1 in Entergy, 2016) 1, 2 Flooding Initial Water Mississippi Resulting Head Change in Water Scenario ( # 1 )
Elevation at River Water Differential Elevation at Site Site, ft.-MSL Elevation, ft.-
Elevation at between after Levee
(#2)
MSL (#3)
Site after River and Breach, ft. (#6)4 Levee Site prior to Breach, ft.-
Levee MSL (#4)
Breach, ft.
(#5)4 Column 2
3 4
5 6
H.2 -Water level 17.09 30.03 20.83 12.94 3.74 in river at top of levee elevation and site dry H.1 - PMF+
20.53 30.03 23.38 9.5 2.85 Upstream Dam Failure H.3-Storm Surge 25.73 31.33 28.00 5.6 2.27
+ 25-yr flood No Offshore Decay (302)
H.3-Storm Surge 24.03 29.53 25.97 5.5 1.94
+ 25-yr flood Offshore Decay Interpolated Information based on Figure 19-1 in Entergy, 2016 H.3 Storm 401a3 20.53 31.93 23.93 11.4 3.4 Note:
1 Results at the northwest corner of the Nuclear Plant Island Structure (grid element #24028) are used as representative results at the site. Ground elevation at grid element #24028 is 17.09 ft. MSL.
2 The values in this table were converted NAVD88 to MSL by the staff.
3 Values in the table are taken from the Waterford Steam Electric Station Combined Effects Calculation.
Values in bold for Storm 401 a are derived based on interpolation from plot provided in the information need response.
4 Values in Column 5 were computed by subtracting Column 2 from Column 3. Values in Column 6 were computed by subtracting Column 2 from Column 4.
NUCLEAR REGULATORY COMMISSION REPORT FOR THE AUDIT OF ENTERGY NUCLEAR OPERATIONS, INC'S. FLOOD HAZARD REEVALUATION REPORT SUBMITTAL RELATING TO THE NEAR-TERM TASK FORCE RECOMMENDATION 2.1-FLOODING FOR WATERFORD STEAM ELECTRIC STATION, UNIT 3 DATED November 8, 2017 DISTRIBUTION:
PUBLIC RBernardo, NRR RidsNrrDorllpl4 Resource RidsRgn4MailCenter Resource LQuinn-Willingham, NRO BHarvey, NRO PBMB R/F LQuinn-Willingham, NRO RidsNrrDorl Resource RidsNrrLASLent MWillingham, NRO MShams, NRR RidsNRRDLP Resource RidsNroDsea Resource RidsNrrPMWaterford Resource CCook, NRO RRivera-Lugo, NRO ADAMS Accession No.: ML16181A251
- via email OFFICE NRR/DLP/PBMB/PM NRR/DLP/PBMB/LA NRO/DSEA/RHM/BC NAME JSebroskv Slent SDevlin-Gill DATE 10/30/2017 10/30/2017 9/13/2017 OFFICE NRR/DLP/PBMB/BC NRR/DLP/PBMB/PM NAME MShams JSebrosky DATE 10/31/17 11/8/17 OFFICAL RECORD COPY