Cycle 24, Revision 2, Core Operating Limits Report (COLR)
ML16165A209
Person / Time
Site: Mcguire
Issue date: 05/31/2016
From:
Duke Energy Carolinas
To:
References
MCC-1553.05-00-0618, Rev 2 MCEI-0400-318, Rev 2
Download: ML16165A209 (31)


Text

McGuire Unit 2 Cycle 24 Core Operating Limits Report Revision 2 May 2016 Calculation Number: MCC-1553.05-00-0618, Revision 2 Duke Energy Carolinas, LLC QA Condition 1 MCEl-0400-3 18 Page I Revision 2 The information presented in this report has been prepared and issued in accordance with McGuire Technical Specification 5.6.5.

McGuire 2 Cycle 24 Core Operating Limits Report Implementation Instructions For Revision 2 Revision Description and CR Tracking MCEI-0400-318 Page2 Revision 2 Revision 2 of the McGuire Unit 2 Cycle 24 COLR contains limits specific to the reload core, and is revised to update the pressurizer pressure limits in Table 4 (TS 3.4.1). The power distribution monitoring factors from Appendix A of Revision 0 remain valid and are not transmitted as part of Revision 2.

There is no CR associated with this revision.

Implementation Schedule Revision 2 may become effective immediately upon receipt.

The McGuire Unit 2 Cycle 24 COLR will cease to be effective during No MODE between cycles 24 and 25.

Data Files to be Implemented No data files are transmitted as part of this document.

Revision 0

1 2

MCEI-0400-318 Page 3 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report Effective Date August 20l5 September 2015 May2016 REVISION LOG Pages Affected 1-31, Appendix A*

1-31 1-31 COLR M2C24 COLR, Rev. 0 M2C24 COLR, Rev. 1 M2C24 COLR, Rev. 2

  • Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. Appendix A is included only in the electronic COLR copy sent to the NRC.

L McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page4 Revision 2 1.0 Core Operating Limits Report TS Number 2.1.1 3.1.1 3.1.3 3.1.4 3.1.5 3.1.5 3.1.6 3.1.6 3.1.8 3.2.1 3.2.2 3.2.3 3.3.1 3.4.1 3.5.1 3.5.4 3.7.14 3.9.1 5.6.5 This Core Operating Limits Report (COLR) has been prepared in accordance with the requirements of Technical Specification 5.6.5. The Technical Specifications that reference this report are listed below along with the NRC approved analytical methods used to develop and/or determine COLR parameters in Technical Specifications.

NRC Approved COLR Methodology (Section Technical Specifications COLR Parameter Section 1.1 Number)

Reactor Core Safety Limits RCS Temperature and 2.1 6,7,8,9, 10, 12,15,16 Pressure Safety Limits Shutdown Margin Shutdown Margin 2.2 6,7,8,12,14,15,l6 Moderator Temperature Coefficient MTC 2.3 6,7,8,12,14,16, 17 Rod Group Alignment Limits Shutdown Margin 2.2 6,7,8,12,14,15,l6 Shutdown Bank Insertion Limits Shutdown Margin 2.2 6,7,8,12,14,15,16 Shutdown Bank Insertion Limits Shutdown Bank Insertion 2.4 2,4,6,7,8,9, 10, 12,14, 15, Limit 16 Control Bank Insertion Limits Shutdown Margin 2.2 6,7,8,12,14, 15,16 Control Bank Insertion Limits Control Bank Insertion 2.5 2,4,6,7,8,9, 10,12,14, 15, Limit 16 Physics Tests Exceptions Shutdown Margin 2.2 6,7,8,12,14,15,16 Heat Flux Hot Channel Factor Fq, AFD, OT~T and 2.6 2,4,6,7,8,9, 10, 12,15,16 Penalty Factors Nuclear Enthalpy Rise Hot Channel F~H, AFD and 2.7 2,4,6,7,8,9, 10, 12, 15, 16 Factor Penalty Factors Axial Flux Difference AFD 2.8 2,4,6,7,8,15,16 Reactor Trip System Instrumentation OT~T and OP~T 2.9 6,7,8,9,10, 12,15,16 Setpoints Constants RCS Pressure, Temperature, and Flow RCS Pressure, 2.10 6,7,8,9,10,12 DNB limits Temperature and Flow Accumulators Max and Min Boron Cone.

2.11 6,7,8,12,14,16 Refueling Water Storage Tank Max and Min Boron Cone.

2.12 6,7,8,12,14,16 Spent Fuel Pool Boron Concentration Min Boron Concentration 2.13 6,7,8,12,14,16 Refueling Operations - Boron Min Boron Concentration 2.14 6,7,8,12,14,16 Concentration Core Operating Limits Report (COLR)

Analytical Methods 1.1 None The Selected Licensee Commitments that reference this report are listed below:

COLR NRC Approved SLC Selected Licensing Commitment Section Methodology Number COLR Parameter (Section 1.1 Number) 16.9.14 Borated Water Source-Shutdown Borated Water Volume and 2.15 6,7,8,12,14,16 Cone. for BAT/RWST 16.9.11 Borated Water Source-Operating Borated Water Volume and 2.16 6,7,8,12,14,16 Cone. for BAT/RWST 16.9.7 Standby Shutdown System Standby Makeup Pump Water 2.17 6,7,8,12,14,16 Supply

McGuire 2 Cycle 24 Core Operating Limits Report 1.1 Analytical Methods MCEI-0400-318 Page 5 Revision 2 The analytical methods used to determine core operating limits for parameters identified in Technical Specifications and previously reviewed and approved by the NRC as specified in Technical Specification 5.6.5 are as follows.

1.

WCAP-9272-P-A, "Westinghouse Reload Safety Evaluation Methodology," (W Proprietary).

Revision 0 Report Date: July 1985 Not Used

2. WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model using the NOTRUMP Code," CTf_ Proprietary).

Revision 0 Report Date: August 1985 Addendum 2, "Addendum to the Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code: Safety Injection into the Broken Loop and COSI Condensation Model," CTf_

Proprietary). (Referenced in Duke Letter DPC-06-101)

Revision 1 July 1997

3. WCAP-10266-P-A, "The 1981 Version Of Westinghouse Evaluation Model Using BASH Code",

(W Proprietary).

Revision2 Report Date: March 1987 Not Used

4. WCAP-12945-P-A, Volume 1 and Volumes 2-5, "Code Qualification Document for Best-Estimate Loss of Coolant Analysis," CTf_ Proprietary).

Revision: Volume 1 (Revision 2) and Volumes 2-5 (Revision 1)

Report Date: March 1998

5. BAW-10168P-A, "B&W Loss-of-Coolant Accident Evaluation Model for Recirculating Steam Generator Plants, (B&W Proprietary).

Revision 1 SER Date: January 22, 1991 Revision 2 SER Dates: August 22, 1996 and November 26, 1996 Revision 3 SER Date: June 15, 1994 Not Used

McGuire 2 Cycle 24 Core Operating Limits Report 1.1 Analytical Methods (continued)

MCEI-0400-318 Page 6 Revision 2

6.

DPC-NE-3000-PA, "Thermal-Hydraulic Transient Analysis Methodology," (DPC Proprietary).

Revision Sa Repmt Date: October 2012

7. DPC-NE-3001-PA, "Multidimensional Reactor Transients and Safety Analysis Physics Parameter Methodology," (DPC Proprietary).

Revision Oa Report Date: May 2009 Note: The WLOP Correlation is used for the HZP Steam Line Break DNBR Analysis as approved by the following SER:

Letter from G. Edward Miller (NRC) to Mr. K Henderson (Duke Energy), "Catawba Nuclear Station, Units 1 and 2 and McGuire Nuclear Station Units 1 and 2 - Issuance of Amendments RE:

DPC-NE-3001-P, Multidimensional Reactor Transients and Safety Analysis Physics Parameters Methodology (TAC Nos. MF3119, MF3120, MF3121, and MF3122), March 25, 2015.

8.

DPC-NE-3002-A, "UFSAR Chapter 15 System Transient Analysis Methodology".

Revision 4b Repmt Date: September 2010

9. DPC-NE-2004P-A, "Duke Power Company McGuire and Catawba Nuclear Stations Core Thermal-Hydraulic Methodology using VIPRE-01," (DPC Proprietary).

Revision 2a Report Date: December 2008

10. DPC-NE-2005P-A, "Thermal Hydraulic Statistical Core Design Methodology," (DPC Proprietary).

Revision 4a Report Date: December 2008

11. DPC-NE-2008P-A, "Fuel Mechanical Reload Analysis Methodology Using TAC03," (DPC Proprietary).

Revision 0 Report Date: April 3, 1995 Not Used

12. DPC-NE-2009-P-A, "Westinghouse Fuel Transition Report," (DPC Proprietary).

Revision 3a Report Date: September 2011

McGuire 2 Cycle 24 Core Operating Limits Report 1.1 Analytical Methods (continued)

MCEI-0400-318 Page 7 Revision 2

13. DPC-NE-1004A, "Nuclear Design Methodology Using CASM0-3/SIMULATE-3P."

Revision la Report Date: January 2009 Not Used

14. DPC-NF-2010-A, "Duke Power Company McGuire Nuclear Station Catawba Nuclear Station Nuclear Physics Methodology for Reload Design."

Revision 2a Report Date: December 2009

15. DPC-NE-2011-PA, "Duke Power Company Nuclear Design Methodology Report for Core Operating Limits of Westinghouse Reactors," (DPC Proprietary).

Revision la Report Date: June 2009

16. DPC-NE-1005-PA, "Nuclear Design Methodology Using CASM0-4 I SIMULATE-3 MOX,"

(DPC Proprietary).

Revision 1 Report Date: November 12, 2008

17. DPC-NE-1007-P A, "Conditional Exemption of the EOC MTC Measurement Methodology,"

(DPC and W Proprietary)

Revision 0 Report Date: April 2015

McGuire 2 Cycle 24 Core Operating Limits Report 2.0 Operating Limits MCEI-0400-318 Page 8 Revision 2 Cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the following subsections. These limits have been developed using the NRC approved methodologies specified in Section 1.1.

2.1 Reactor Core Safety Limits (TS 2.1.1) 2.1.1 The Reactor Core Safety Limits are shown in Figure 1.

2.2 Shutdown Margin - SDM (TS 3.1.1, TS 3.1.4, TS 3.1.5, TS 3.1.6 and TS 3.1.8) 2.2.1 For TS 3.1.1, SDM shall be '.::.1.3% ~K/K in MODE 2 with k-eff < 1.0 and in MODES 3 and 4.

2.2.2 For TS 3.1.1, SDM shall be'.:'.:. 1.0% ~K/K in MODE 5.

2.2.3 For TS 3.1.4, SDM shall be '.::.1.3% ~K/K in MODES 1 and 2.

2.2.4 For TS 3.1.5, SDM shall be '.::.1.3% ~K/K in MODE 1 and MODE 2 with any control bank not fully inserted.

2.2.5 For TS 3.1.6, SDM shall be '.::.1.3% ~K/K in MODE 1 and MODE 2 with K-eff:::. 1.0.

2.2.6 For TS 3.1.8, SDM shall be '.::.1.3% ~K/K in MODE 2 during PHYSICS TESTS.

McGuire 2 Cycle 24 Core Operating Limits Report Figure 1 Reactor Core Safety Limits Four Loops in Operation MCEI-0400-318 Page 9 Revision 2 DO NOT OPERA TE IN THIS AREA 660 t------+-------1--------+

---t

~ 630 l------t------"'"""'-::--t----------11-----~=---------1-~----l Of)

~

t-c Cl)

~ 620 0.0 0.2 ACCEPTABLE OPERATION 0.4 0.6 0.8 1.0 1.2 Fraction of Rated Thermal Power

McGuire 2 Cycle 24 Core Operating Limits Report 2.3 Moderator Temperature Coefficient - MTC (TS 3.1.3) 2.3.l The Moderator Temperature Coefficient (MTC) Limits are:

MCEI-0400-318 Page 10 Revision 2 MTC shall be less positive than the upper limits shown in Figure 2. BOC, ARO, HZP MTC shall be less positive than 0.7E-04 LiKIK/°F.

EOC, ARO, RTP MTC shall be less negative than the -4.3E-04 ~°F lower MTC limit.

2.3.2 300 PPM MTC Surveillance Limit is:

Measured 300 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to -3.65E-04 Af(/K/°F.

2.3.3 The Revised Predicted near-EOC 300 PPM ARO RTP MTC shall be calculated using the procedure contained in DPC-NE-1007-PA If the Revised Predicted MTC is less negative than or equal to the 300 PPM SR 3.1.3.2 Surveillance Limit, and all benchmark data contained in the surveillance procedure is satisfied, then an MTC measurement in accordance with SR 3.1.3.2 is not required to be performed.

2.3.4 60 PPM MTC Surveillance Limit is:

60 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to

-4.125E-04 LiKIK/°F.

Where:

BOC = Beginning of Cycle (bumup corresponding to the most positive MTC)

EOC = End of Cycle ARO = All Rods Out HZP = Hot Zero Power R TP = Rated Thermal Power PPM = Parts per million (Boron) 2.4 Shutdown Bank Insertion Limit (TS 3.1.5) 2.4.1 Each shutdown bank shall be withdrawn to at least 222 steps. Shutdown banks are withdrawn in sequence and with no overlap.

2.5 Control Bank Insertion Limits (TS 3.1.6) 2.5.1 Control banks shall be within the insertion, sequence, and overlap limits shown in Figure 3. Specific control bank withdrawal and overlap limits as a function of the fully withdrawn position are shown in Table 1.

1.0 0.9 0.8

=

~

0.7

(,J

~

0 u~ 0.6

~ 0

~~ 0.5

~ <l 0.4

c. "':!"

89

~~ 0.3 oC

~

0.2

~

"C 0

0.1

~

0.0 McGuire 2 Cycle 24 Core Operating Limits Report Figure 2 MCEI-0400-318 Page 11 Revision 2 Moderator Temperature Coefficient Upper Limit Versus Power Level Unacceptable Operation Acceptable Operation 0

10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power NOTE: Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to OP/2/ A/6100/22 Unit 2 Data Book for details.

231 220 200

,-_ = 180

i
:

ell -

] 160

~ 140

g.

cu

~ 120

=

.s 100 c

~ 80

=

.s

..... - 60 cu

"' =

"O c 40

~

20 0

MCEI-0400-318 Page 12 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report Figure3 Control Bank Insertion Limits Versus Percent Rated Thermal Power Fully Withdrawn (Maximum= 23j~

~ - -

~

~ -

/

/

/

/

/

/

/

/

/

/

Fully Withdrawn

/

/

/

Control Bank B ~

(Min~mum = 222)

/

/

/

J I (100%, 161) !=

./

./

~ (0%, 163)

/

/

/

/

./

/

/

/

J

/

./

/

Control Bank C

/

/

/

./

/

/

J

/

/

/

/

/

./

/

/

Control Bank D

/

/

/

/

./

/

1=j *co%, 47) 1

/

/

J

~

] Fully Inserted

/

/

(30%, 0)

I

/

0 10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power The Rod Insertion Limits (RIL) for Control Bank D (CD), Control Bank C (CC), and Control Bank B (CB) can be calculated by:

Bank CD RIL = 2.3(P)- 69 {30<PS100}

Bank CC RIL = 2.3(P) +47

{O < P < 76.1} for CC RIL = 222{76.1<PS100}

Bank CB RIL = 2.3(P) + 163 {O < P < 25. 7} for CB RIL = 222 {25. 7 < P <JOO}

where P = %Rated Thermal Power NOTE:

Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to OP/2/ A/6100/22 Unit 2 Data Book for details.

McGuire 2 Cycle 24 Core Operating Limits Report Table 1 RCCA Withdrawal Steps and Sequence Fully Withdrawn at 222 Steps Control Control Control Control Bank A Bank B Bauk C Bank D 0 Start 116 222 Stop 222 222 222 222 0

0 Start 106 116 222 Stop 222 222 0

0 0

O Start 106 116 222 Stop 0

0 0

0 0

0 Start 106 Fully Withdrawn at 224 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 116 224 Stop 224 224 224 224 0

0 0 Start 0

108 0

116 O Start 224 Stop

!08 224 116 224 224 Stop 0

0 0

0 0

0 Start 108 Fully Withdrawn at 226 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

116 OStart 226 Stop 110 226 116 226 226 Stop 226 226 226 226 0

0 0

0 Start 110 116 226 Stop 0

0 0

0 0

0 Start 110 Fully Withdrawn at 228 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 116 228 Stop 228 228 228 228 0

0 Start 112 116 228 Stop 228 228 0

0 0

0 Start 112 116 228 Stop 0

0 0

0 0

0 Start 112 Fully Withdrawn at 230 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 230 Stop 114 0

0 230 116 0 Start 0

230 230 Stop 114 0

230 230 116 0 Start 230 230 230 Stop 114 Fully Withdrawn at 223 Steps Control Control BankA BankB 0 Start 116 223 Stop 223 223 223*

223 0

0 Start 107 116 223 Stop 223 223 Control BankC 0

0 0

O Start 107 116 223 Stop Control BankD 0

0 0

0 0

0 Start 107 Fully Withdrawn at 225 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 116 225 Stop 225 225 225 225 0

0 Start 109 116 225 Stop 225 225 0

0 0

0 Start 109 116 225 Stop 0

0 0

0 0

0 Start 109 Fully Withdrawn at 227 Steps Control Control BankA BankB 0 Start 116 227 Stop 227 227 227 227 0

0 Start Ill 116 227 Stop 227 227 Control BankC 0

0 0

0 Start 111 116 227 Stop Control BankD 0

0 0

0 0

0 Start Ill Fnlly Withdrawn at 229 Steps Control BankA 0 Start 116 229 Stop 229 229 229 229 Control BankB 0

0 Start 113 116 229 Stop 229 229 Control BankC 0

0 0

O Start 113 116 229 Stop Control BankD 0

0 0

0 0

0 Start 113 Fully Withdrawn at 231 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 231 Stop 115 0

o 231 116 0 Start o

231 231 Stop 115 o

231 231 116 0 Start 231 231 231Stop 115 MCEI-0400-318 Page 13 Revision 2

McGuire 2 Cycle 24 Core Operating Limits Report 2.6 Heat Flux Hot Channel Factor-FQ(X,Y,Z) (TS 3.2.1)

MCEI-0400-318 Page 14 Revision2 2.6.1 FQ(X, Y,Z) steady-state limits are defined by the following relationships:

where, F ~TP *K(Z)/P F ~TP *K(Z)/0.5 for P > 0.5 for P :S 0.5 P =(Thermal Power)/(Rated Power)*

Note: The measured FQ(X,Y,Z) shall be increased by 3% to account for manufacturing tolerances and 5% to account for measurement uncertainty when comparing against the LCO limits. The manufacturing tolerance and measurement uncertainty are implicitly included in the FQ surveillance limits as defined in Sections 2.6.5 and 2.6.6.

2.6.2 p~TP = 2.70 x K(BU) 2.6.3 K(Z) is the normalized FQ(X,Y,Z) as a function of core height. The K(Z) function for Westinghouse RFA fuel is provided in Figure 4.

2.6.4 K(BU) is the normalized F Q(X, Y,Z) as a function of bumup. F ~TP with the K(BU) penalty for Westinghouse RFA fuel is analytically confirmed in cycle-specific reload calculations. K(BU) is set to 1.0 at all bumups.

The following parameters are required for core monitoring per the Surveillance Requirements ofTechnical Specification 3.2.1:

L F~(X, Y,Z)

  • M9(X, Y,Z) 2.6.5 FQ(X,Y,Z)OP =

UMT *MT* TILT

where:

MCEI-0400-318 Page 15 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report F~ (X,Y,Z)OP =

Cycle dependent maximum allowable design peaking factor that ensures FQ(X,Y,Z) LOCA limit will be preserved for operation within the LCO limits. F~ (X,Y,z)OP includes allowances for calculation and measurement uncertainties.

Ft(X,Y,Z)

MQ(X,Y,Z)

UMT MT TILT Design power distribution for FQ. Ft (X,1:'",Z) is provided in Appendix Table A-1 for normal operating conditions, and in Appendix Table A-4 for power escalation testing during initial startup operation.

Margin remaining in core location X,Y,Z to the LOCA limit in the transient power distribution. MQ(X,Y,Z) is provided in Appendix Table A-1 for normal operating conditions and in Appendix Table A-4 for power escalation testing during initial startup operation.

Total Peak Measurement Uncertainty. (UMT = 1.05)

Engineering Hot Channel Factor. (MT= 1.03)

Peaking penalty to account for allowable quadrant power tilt ratio of 1.02. (TILT= 1.035)

L RPS 2.6.6 FQ(X,Y,Z)

=

F~(X,Y,Z)

  • Mc(X,Y,Z)

UMT *MT* TILT where:

Ft(X,Y,Z)RPS =

Cycle dependent maximum allowable design peaking factor that ensures the FQ(X,Y,Z) Centerline Fuel Melt (CFM) limit will be preserved for operation within the LCO limits.

Ft(X,Y,Z)RPS includes allowances for calculation and measurement uncertainties.

D FQ(X,Y,Z)

Defined in Section 2.6.5.

McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page 16 Revision 2 Mc(X,Y,Z) = Margin remaining to the CFM limit in core location X,Y,Z from the transient power distribution. Mc(X,Y,Z) is provided in Appendix Table A-2 for normal operating conditions and in Appendix Table A-5 for power escalation testing during initial startup operation.

UMT Defined in Section 2.6.5.

MT Defined in Section 2.6.5.

TILT Defined in Section 2.6.5.

2.6.7 KSLOPE = 0.0725 where:

KSLOPE is the adjustment to K1 value from the OT~T trip setpoint required to RPS compensate for each 1 % that F/; (X,Y,Z) exceeds F~ (X,Y,Z) 2.6.8 FQ(X,Y,Z) penalty factors for Technical Specification Surveillances 3.2.1.2 and 3.2.1.3 are provided in Table 2.

MCEI-0400-318 Page 17 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report Figure 4 K(Z), Normalized FQ(X,Y,Z) as a Function of Core Height for Westinghouse RFA Fuel 1.200 ~--------------------------~

(0.0, 1.00)

(4.0, 1.00) i.ooo.,_ ________...

1 0.800 g 0.600

~

0.400 0.200 Core Heii:;ht (ft}

0.0

S4.0

>4.0 12.0 (4.0, 0.9259)

K(Z}

1.0 1.0 0.9259 0.9259 (12.0, 0.9259) 0.000 +------+------+-----+------+-----+--------<

0.0 2.0 4.0 6.0 8.0 10.0 12.0 Core Height (ft)

McGuire 2 Cycle 24 Core Operating Limits Report Table 2 FQ(X,Y,Z) and F AfI{X,Y) Penalty Factors MCEI-0400-318 Page 18 Revision 2 For _Technical Specification Surveillance's 3.2.1.2, 3.2.1.3 and 3.2.2.2 Burn up FQ(X,Y,Z)

FLrn(X,Y)

(EFPD)

Penalty Factor (%)

Penalty Factor(%)

0 2.00 2.00 4

2.00 2.00 12 2.51 2.00 25 2.21 2.00 50 2.00 2.00 75 2.00 2.00 100 2.00 2.00 125 2.00 2.00 150 2.00 2.00 175 2.00 2.00 200 2.00 2.00 225 2.00 2.00 250 2.00 2.00 275 2.00 2.00 300 2.00 2.00 325 2.00 2.00 350 2.00 2.00 375 2.00 2.00 400 2.00 2.00 425 2.00 2.00 450 2.00 2.00 465 2.00 2.00 475 2.00 2.00 496 2.00 2.00 511 2.00 2.00 521 2.00 2.00 531 2.00 2.00 Note: Linear interpolation is adequate for intermediate cycle burnups. All cycle burnups outside of the range of the table shall use a 2% penalty factor for both FQ(X,Y,Z) and F ~H(X,Y) for compliance with the Technical Specification Surveillances 3.2.1.2, 3.2.1.3 and 3.2.2.2.

McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page 19 Revision 2 2.7 Nuclear Enthalpy Rise Hot Channel Factor - F MJ(X,Y) (TS 3.2.2)

F ~H steady-state limits referred to in Technical Specification 3.2.2 is defined by the following relationship.

2.7.1 Fltt(X, Y)LCO= MARP (X,Y) * [ 1.0 + ~

  • (1.0 - P)J where:

FkH (X, Y)Lco is the steady-state, maximum allowed radial peak and includes allowances for calculation/measurement uncertainty.

MARP(X,Y) = Cycle-specific operating limit Maximum Allowable Radial Peaks. MARP(X,Y) radial peaking limits are provided in Table 3.

Thermal Power p = ~~~~~,....-~-

Rated Thermal Power RRH = Thermal Power reduction required to compensate for each 1 % that the measured radial peak, F~ (X,Y), exceeds its limit. RRH also is used to scale the MARP limits as a function of power per the FkH (X, Y) Leo equation. (RRH = 3.34 (0.0 < P ~ 1.0))

The following parameters are required for core monitoring per the surveillance requirements of Technical Specification 3.2.2.

2.7.2 L

SURV -

FfH (X, Y) x M iiH (X, Y)

F iiH (X, Y)

-="-------"'"-'----

UMR x TILT where:

L SURV _

F8H (X,Y)

Cycle dependent maximum allowable design peaking factor that ensures the F 8 H(X, Y) limit will be preserved for operation within the LCO limits. FkH (X,Y)suRv includes allowances for calculation/measurement uncertainty.

MCEI-0400-318 Page 20 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report F~H (X,Y) = Design radial power distribution for Fm* F~H (X,Y) is provided in Appendix Table A-3 for normal operation and in Appendix Table A-6 for power escalation testing during initial startup operation.

M11H(X, Y) =The margin remaining in core location X, Y relative to the Operational DNB limits in the transient power distribution.

Mm(X,Y) is provided in Appendix Table A-3 for normal operation and in Appendix Table A-6 for power escalation testing during initial startup operation.

UMR =Uncertainty value for measured radial peaks (UMR = 1.0).

UMR is 1.0 since a factor of 1.04 is implicitly included in the variable M1m(X,Y).

TILT = Peaking penalty to account for allowable quadrant power tilt ratio of 1.02 (TILT= 1.035).

2.7.3 RRH is defined in Section 2.7.1.

2.7.4 TRH=0.04 where:

TRH =Reduction in the OT Ll T K 1 setpoint required to compensate for each 1 %

that the measured radial peak, F~ (X,Y) exceeds its limit.

2.7.5 F~H (X,Y) penalty factors for Technical Specification Surveillance 3.2.2.2 are provided in Table 2.

2.8 Axial Flux Difference - AFD (TS 3.2.3) 2.8.1 The Axial Flux Difference (AFD) Limits are provided in Figure 5.

Core Ht (ft.)

1.05 1.2 0.12 1.8092 1.8553 1.9248 1.2 1.8102 1.8540 1.9248 2.4 1.8093 1.8525 1.9312 3.6 1.8098 1.8514 1.9204 4.8 1.8097 1.8514 1.9058 6.0 1.8097 1.8514 1.8921 7.2 1.8070 1.8438 1.8716 8.4 1.8073 1.8319 1.8452 9.6 1.8072 1.8102 1.8093 10.8 1.7980 1.7868 1.7611 11.4 1.7892 1.7652 1.7250 McGuire 2 Cycle 24 Core Operating Limits Report Table 3 Maximum Allowable Radial Peaks (MARPS)

RFAMARPS Axial Peak 1.3 1.4 1.5 1.6 1.7 1.8 1.9146 1.9179 2.0621 2.0498 2:0090 1.9333 1.9146 1.9179 2.1073 2.0191 1.9775 1.9009 1.9146 1.9179 2.0735 1.9953 1.9519 1.8760 1.9146 1.9179 2.0495 1.9656 1.9258 1.8524 1.9146 1.9179 2.0059 1.9441 1.9233 1.8538 1.9212 1.9179 1.9336 1.8798 1.8625 1.8024 1.8930 1.8872 1.8723 1.8094 1.7866 1.7332 1.8571 1.8156 1.7950 1.7359 1.7089 1.6544 1.7913 1.7375 1.7182 1.6572 1.6347 1.5808 1.7163 1.6538 1.6315 1.5743 1.5573 1.5088 1.6645 1.6057 1.5826 1.5289 1.5098 1.4637 1.9 1.8625 1.8306 1.8054 1.7855 1.7836 1.7472 1.6812 1.6010 1.5301 1.4624 1.4218 MCEI-0400-318 Page 21 Revision 2 2.1 3.0 1.7780 1.3151 1.7852 1.3007 1.7320 1.4633 1.6996 1.4675 1.6714 1.2987 1.6705 1.3293 1.5982 1.2871 1.5127 1.2182 1.4444 1.1431 1.3832 1.1009 1.3458 1.0670 3.25 1.2461 1.2235 1.4616 1.3874 1.2579 1.2602 1.2195 1.1578 1.0914 1.0470 1.0142

-50 MCEI-0400-318 Page 22 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report Figure 5 Percent of Rated Thermal Power Versus Percent Axial Flux Difference Limits

(-18, 100)

(+10, 100)

Unacceptable Operation 90 Unacceptable Operation 80 Acceptable Operation 70 60 50

(-36, 50)

(+21, 50) 40 30 20 10

-40

-30

-20

-10 0

10 20 30 40 50 Axial Flux Difference (% Delta I)

NOTE: Compliance with Technical Specification 3.2.l may require more restrictive AFD limits. Refer to OP/2/A/6100/22 Unit 2 Data Book for more details.

McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page 23 Revision 2 2.9 Reactor Trip System Instrumentation Setpoints (TS 3.3.1) Table 3.3.1-1 2.9.l Overtemperature AT Setpoint Parameter Values Parameter Nominal Tavg at RTP Nominal RCS Operating Pressure Overtemperature Ii T reactor trip setpoint Ove11emperature /j.T reactor trip heatup setpoint penalty coefficient Overtemperature /j. T reactor trip depressurization setpoint penalty coefficient Time constants utilized in the lead-lag compensator for !iT Time constant utilized in the lag compensator for Ii T Time constants utilized in the lead-lag compensator for Tavg Time constant utilized in the measured T avg lag compensator f1 (/j.I) "positive" breakpoint f 1 (/j.I) "negative" breakpoint fi (/j.I) "positive" slope f 1 (/j.I) "negative" slope T'.:S 585.1°F P' = 2235 psig Kl.:S 1.1978 K2 = 0.03341°F K3 = 0.001601/psi

't 1 ::::: 8 sec.

't2 _:::: 3 sec.

't3 :::; 2 sec.

't4::::: 28 sec.

'tS _:::: 4 sec.

't6 :::; 2 sec.

= 19.0 %/j.I

=NIA*

=NIA*

The f1 (M) "negative" breakpoint and the fi (M) "negative" slope are less restrictive than the OP/j.T f1(!1I) negative breakpoint and slope. Therefore, during a transient which challenges the negative imbalance limits, the OP Ii T f1(/j.I) limits will result in a reactor trip before the OT Ii T fi (M) limits are reached. This makes implementation of the OT/j.T fi (M) negative breakpoint and slope unnecessary.

MCEI-0400-318 Page 24 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report 2.9.2 Overpower AT Setpoint Parameter Values Parameter Nominal Tavg at RTP Overpower !ff reactor trip setpoint Overpower ~ T reactor trip Penalty Overpower ~T reactor trip heatup setpoint penalty coefficient Time constants utilized in the lead-lag compensator for ~ T Time constant utilized in the lag compensator for ~T Time constant utilized in the measured Tavg lag compensator Time constant utilized in the rate-lag controller for Tavg fi(M) "positive" breakpoint fi(M) "negative" breakpoint f2(M) "positive" slope fi(M) "negative" slope T" :S 585.1°F Ks= 0.02/°F for ~ncreasing Tavg Ks= 0.0 for decreasing Tavg K6 = 0.001179/°F for T > T" K6 = 0.0 for T :ST"

  • i :'.".: 8 sec.
  • 2 :=: 3 sec.
  • 3 ::: 2 sec.
  • 6 :=: 2 sec.
  • 7 :'.".: 5 sec.

= 35.0 %~I

=-35.0 %M

= 7.0 %~Tof %~I

= 7.0 %~T0/ %~I

McGuire 2 Cycle 24 Core Operating Limits Report 2.10. RCS Pressure, Temperature and Flow Limits for DNB (TS 3.4.1)

MCEI-0400-318 Page 25 Revision 2 2.10.1 RCS pressure, temperature and flow limits for DNB are shown in Table 4.

2.11 Accumulators (TS 3.5.1) 2.11.1 Boron concentration limits during MODES 1 and 2, and MODE 3 with RCS pressure > 1000 psi:

Parameter Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator maximum boron concentration.

Applicable Burnup 0 -200 EFPD 200.1 - 250 EFPD 250.1 - 300 EFPD 300.1 - 350 EFPD 350.1 - 400 EFPD 400.1 - 450 EFPD 450. l - 465 EFPD 465.1 - 521 EFPD 521.1 - 531 EFPD 0- 531 EFPD 2.12 Refueling Water Storage Tank - RWST (TS 3.5.4) 2.12.1 Boron concentration limits during MODES 1, 2, 3, and 4:

Parameter R WST minimum boron concentration.

R WST maximum boron concentration.

Limit 2,475 ppm 2,475 ppm 2,398 ppm 2,292 ppm 2,214 ppm 2,143 ppm 2,077 ppm 2,057 ppm 1,972 ppm 2,875 ppm Limit 2,675 ppm 2,875 ppm

McGuire 2 Cycle 24 Core Operating Limits Report Table 4 Reactor Coolant System DNB Parameters No. Operable Parameter Indication Channels

1. Indicated RCS Average Temperature meter 4

meter 3

computer 4

computer 3

2. Indicated Pressurizer Pressure meter 4

meter 3

computer 4

computer 3

3. RCS Total Flow Rate MCEI-0400-318 Page 26 Revision 2 Limits
S 587.2 °F
S 586.9 °F
S 587.7 °F
S 587.5 °F
2212.3 psig
2215.0 psig
2209.1 psig
2211.3 psig
388,000 gpm

McGuire 2 Cycle 24 Core Operating Limits Report 2.13 Spent Fuel Pool Boron Concentration (TS 3.7.14)

MCEI-0400-318 Page 27 Revision 2 2.13.1 Minimum boron concentration limit for the spent fuel pool. Applicable when fuel assemblies are stored in the spent fuel pool.

Parameter Spent fuel pool minimum boron concentration.

2,675 ppm 2.14 Refueling Operations - Boron Concentration (TS 3.9.1) 2.14.1 Minimum boron concentration limit for the filled portions of the Reactor Coolant System, refueling canal, and refueling cavity for MODE 6 conditions. The minimum boron concentration limit and plant refueling procedures ensure that core Keff remains within MODE 6 reactivity requirement of Keff.::::: 0.95.

Parameter Minimum boron concentration of the Reactor Coolant System, the refueling canal, and the refueling cavity.

2,675 ppm

MCEl-0400-318 Page 28 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report 2.15 Borated Water Source - Shutdown (SLC 16.9.14) 2.15.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during MODE 4 with any RCS cold leg temperature.:S 300 °F and MODES 5 and 6.

Parameter Note: When cycle burnup is > 476 EFPD, Figure 6 may be used to determine required BAT minimum level.

BAT minimum contained borated water volume BAT minimum boron concentration BAT minimum water volume required to maintain SDM at 7,000 ppm RWST minimum contained borated water volume RWST minimum boron concentration RWST minimum water volume required to maintain SDM at 2,675 ppm 10,599 gallons 13.6% Level 7,000 ppm 2,300 gallons 47,700 gallons 41 inches 2,675 ppm 8,200 gallons

MCEI-0400-318 Page 29 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report 2.16 Borated Water Source - Operating (SLC 16.9.11) 2.16.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during MODES I, 2, 3, and MODE 4 with all RCS cold leg temperature> 300 °F.

Parameter Note: When cycle burnup is > 476 EFPD, Figure 6 may be used to determine required BAT minimum level.

BAT minimum contained borated water volume BAT minimum boron concentration BAT minimum water volume required to maintain SDM at 7,000 ppm R WST minimum contained borated water volume RWST minimum boron concentration RWST maximum boron concentration (TS 3.5.4)

RWST minimum water volume required to maintain SDM at 2,675 ppm 2.17 Standby Shutdown System - (SLC-16.9.7) 22,049 gallons 38.0% Level 7,000 ppm 13,750 gallons 96,607 gallons 103.6 inches 2,675 ppm 2,875 ppm 57, 107 gallons 2.17.1 Minimum boron concentration limit for the spent fuel pool required for Standby Makeup Pump Water Supply. Applicable for MODES 1, 2, and 3.

Parameter Spent fuel pool minimum boron concentration for TR 16.9.7.2.

2,675 ppm

McGuire 2 Cycle 24 Core Operating Limits Report Figure 6 Boric Acid Storage Tank Indicated Level Versus RCS Boron Concentration (Valid When Cycle Burnup is> 476 EFPD)

MCEI-0400-318 Page 30 Revision 2 This figure includes additional volumes listed in SLC 16.9.14 and 16.9.11 40.0,-----------------------~--.,-------------,

35.0 30.0 I

Acceptable 10.0 I Unacceptable Operation I 5.0 j

RCS Boron Concentration BAT Level (ppm)

(%level) 0 < 300 37.0 300 < 500 33.0 500 < 700 28.0 700 < 1000 23.0.

1000 < 1300 1~

~ 1300 8.7 O.O-t-------;---.----~----r--.---~--r---~----r--.---~--r---~---1 0

200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 RCS Boron Concentration (ppmb)

McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page 31 Revision 2 NOTE: Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. This data was generated in the McGuire 2 Cycle 24 Maneuvering Analysis calculation file, MCC-1553.05-00-0613. Due to the size of the monitoring factor data, Appendix A is controlled electronically within Duke and is not included in the Duke internal copies of the COLR. The Plant Nuclear Engineering Section will control this information via computer file(s) and should be contacted if there :is a need to access this information.

Appendix A is included in the COLR copy transmitted to the NRC.

McGuire Unit 2 Cycle 24 Core Operating Limits Report Revision 2 May 2016 Calculation Number: MCC-1553.05-00-0618, Revision 2 Duke Energy Carolinas, LLC QA Condition 1 MCEl-0400-3 18 Page I Revision 2 The information presented in this report has been prepared and issued in accordance with McGuire Technical Specification 5.6.5.

McGuire 2 Cycle 24 Core Operating Limits Report Implementation Instructions For Revision 2 Revision Description and CR Tracking MCEI-0400-318 Page2 Revision 2 Revision 2 of the McGuire Unit 2 Cycle 24 COLR contains limits specific to the reload core, and is revised to update the pressurizer pressure limits in Table 4 (TS 3.4.1). The power distribution monitoring factors from Appendix A of Revision 0 remain valid and are not transmitted as part of Revision 2.

There is no CR associated with this revision.

Implementation Schedule Revision 2 may become effective immediately upon receipt.

The McGuire Unit 2 Cycle 24 COLR will cease to be effective during No MODE between cycles 24 and 25.

Data Files to be Implemented No data files are transmitted as part of this document.

Revision 0

1 2

MCEI-0400-318 Page 3 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report Effective Date August 20l5 September 2015 May2016 REVISION LOG Pages Affected 1-31, Appendix A*

1-31 1-31 COLR M2C24 COLR, Rev. 0 M2C24 COLR, Rev. 1 M2C24 COLR, Rev. 2

  • Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. Appendix A is included only in the electronic COLR copy sent to the NRC.

L McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page4 Revision 2 1.0 Core Operating Limits Report TS Number 2.1.1 3.1.1 3.1.3 3.1.4 3.1.5 3.1.5 3.1.6 3.1.6 3.1.8 3.2.1 3.2.2 3.2.3 3.3.1 3.4.1 3.5.1 3.5.4 3.7.14 3.9.1 5.6.5 This Core Operating Limits Report (COLR) has been prepared in accordance with the requirements of Technical Specification 5.6.5. The Technical Specifications that reference this report are listed below along with the NRC approved analytical methods used to develop and/or determine COLR parameters in Technical Specifications.

NRC Approved COLR Methodology (Section Technical Specifications COLR Parameter Section 1.1 Number)

Reactor Core Safety Limits RCS Temperature and 2.1 6,7,8,9, 10, 12,15,16 Pressure Safety Limits Shutdown Margin Shutdown Margin 2.2 6,7,8,12,14,15,l6 Moderator Temperature Coefficient MTC 2.3 6,7,8,12,14,16, 17 Rod Group Alignment Limits Shutdown Margin 2.2 6,7,8,12,14,15,l6 Shutdown Bank Insertion Limits Shutdown Margin 2.2 6,7,8,12,14,15,16 Shutdown Bank Insertion Limits Shutdown Bank Insertion 2.4 2,4,6,7,8,9, 10, 12,14, 15, Limit 16 Control Bank Insertion Limits Shutdown Margin 2.2 6,7,8,12,14, 15,16 Control Bank Insertion Limits Control Bank Insertion 2.5 2,4,6,7,8,9, 10,12,14, 15, Limit 16 Physics Tests Exceptions Shutdown Margin 2.2 6,7,8,12,14,15,16 Heat Flux Hot Channel Factor Fq, AFD, OT~T and 2.6 2,4,6,7,8,9, 10, 12,15,16 Penalty Factors Nuclear Enthalpy Rise Hot Channel F~H, AFD and 2.7 2,4,6,7,8,9, 10, 12, 15, 16 Factor Penalty Factors Axial Flux Difference AFD 2.8 2,4,6,7,8,15,16 Reactor Trip System Instrumentation OT~T and OP~T 2.9 6,7,8,9,10, 12,15,16 Setpoints Constants RCS Pressure, Temperature, and Flow RCS Pressure, 2.10 6,7,8,9,10,12 DNB limits Temperature and Flow Accumulators Max and Min Boron Cone.

2.11 6,7,8,12,14,16 Refueling Water Storage Tank Max and Min Boron Cone.

2.12 6,7,8,12,14,16 Spent Fuel Pool Boron Concentration Min Boron Concentration 2.13 6,7,8,12,14,16 Refueling Operations - Boron Min Boron Concentration 2.14 6,7,8,12,14,16 Concentration Core Operating Limits Report (COLR)

Analytical Methods 1.1 None The Selected Licensee Commitments that reference this report are listed below:

COLR NRC Approved SLC Selected Licensing Commitment Section Methodology Number COLR Parameter (Section 1.1 Number) 16.9.14 Borated Water Source-Shutdown Borated Water Volume and 2.15 6,7,8,12,14,16 Cone. for BAT/RWST 16.9.11 Borated Water Source-Operating Borated Water Volume and 2.16 6,7,8,12,14,16 Cone. for BAT/RWST 16.9.7 Standby Shutdown System Standby Makeup Pump Water 2.17 6,7,8,12,14,16 Supply

McGuire 2 Cycle 24 Core Operating Limits Report 1.1 Analytical Methods MCEI-0400-318 Page 5 Revision 2 The analytical methods used to determine core operating limits for parameters identified in Technical Specifications and previously reviewed and approved by the NRC as specified in Technical Specification 5.6.5 are as follows.

1.

WCAP-9272-P-A, "Westinghouse Reload Safety Evaluation Methodology," (W Proprietary).

Revision 0 Report Date: July 1985 Not Used

2. WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model using the NOTRUMP Code," CTf_ Proprietary).

Revision 0 Report Date: August 1985 Addendum 2, "Addendum to the Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code: Safety Injection into the Broken Loop and COSI Condensation Model," CTf_

Proprietary). (Referenced in Duke Letter DPC-06-101)

Revision 1 July 1997

3. WCAP-10266-P-A, "The 1981 Version Of Westinghouse Evaluation Model Using BASH Code",

(W Proprietary).

Revision2 Report Date: March 1987 Not Used

4. WCAP-12945-P-A, Volume 1 and Volumes 2-5, "Code Qualification Document for Best-Estimate Loss of Coolant Analysis," CTf_ Proprietary).

Revision: Volume 1 (Revision 2) and Volumes 2-5 (Revision 1)

Report Date: March 1998

5. BAW-10168P-A, "B&W Loss-of-Coolant Accident Evaluation Model for Recirculating Steam Generator Plants, (B&W Proprietary).

Revision 1 SER Date: January 22, 1991 Revision 2 SER Dates: August 22, 1996 and November 26, 1996 Revision 3 SER Date: June 15, 1994 Not Used

McGuire 2 Cycle 24 Core Operating Limits Report 1.1 Analytical Methods (continued)

MCEI-0400-318 Page 6 Revision 2

6.

DPC-NE-3000-PA, "Thermal-Hydraulic Transient Analysis Methodology," (DPC Proprietary).

Revision Sa Repmt Date: October 2012

7. DPC-NE-3001-PA, "Multidimensional Reactor Transients and Safety Analysis Physics Parameter Methodology," (DPC Proprietary).

Revision Oa Report Date: May 2009 Note: The WLOP Correlation is used for the HZP Steam Line Break DNBR Analysis as approved by the following SER:

Letter from G. Edward Miller (NRC) to Mr. K Henderson (Duke Energy), "Catawba Nuclear Station, Units 1 and 2 and McGuire Nuclear Station Units 1 and 2 - Issuance of Amendments RE:

DPC-NE-3001-P, Multidimensional Reactor Transients and Safety Analysis Physics Parameters Methodology (TAC Nos. MF3119, MF3120, MF3121, and MF3122), March 25, 2015.

8.

DPC-NE-3002-A, "UFSAR Chapter 15 System Transient Analysis Methodology".

Revision 4b Repmt Date: September 2010

9. DPC-NE-2004P-A, "Duke Power Company McGuire and Catawba Nuclear Stations Core Thermal-Hydraulic Methodology using VIPRE-01," (DPC Proprietary).

Revision 2a Report Date: December 2008

10. DPC-NE-2005P-A, "Thermal Hydraulic Statistical Core Design Methodology," (DPC Proprietary).

Revision 4a Report Date: December 2008

11. DPC-NE-2008P-A, "Fuel Mechanical Reload Analysis Methodology Using TAC03," (DPC Proprietary).

Revision 0 Report Date: April 3, 1995 Not Used

12. DPC-NE-2009-P-A, "Westinghouse Fuel Transition Report," (DPC Proprietary).

Revision 3a Report Date: September 2011

McGuire 2 Cycle 24 Core Operating Limits Report 1.1 Analytical Methods (continued)

MCEI-0400-318 Page 7 Revision 2

13. DPC-NE-1004A, "Nuclear Design Methodology Using CASM0-3/SIMULATE-3P."

Revision la Report Date: January 2009 Not Used

14. DPC-NF-2010-A, "Duke Power Company McGuire Nuclear Station Catawba Nuclear Station Nuclear Physics Methodology for Reload Design."

Revision 2a Report Date: December 2009

15. DPC-NE-2011-PA, "Duke Power Company Nuclear Design Methodology Report for Core Operating Limits of Westinghouse Reactors," (DPC Proprietary).

Revision la Report Date: June 2009

16. DPC-NE-1005-PA, "Nuclear Design Methodology Using CASM0-4 I SIMULATE-3 MOX,"

(DPC Proprietary).

Revision 1 Report Date: November 12, 2008

17. DPC-NE-1007-P A, "Conditional Exemption of the EOC MTC Measurement Methodology,"

(DPC and W Proprietary)

Revision 0 Report Date: April 2015

McGuire 2 Cycle 24 Core Operating Limits Report 2.0 Operating Limits MCEI-0400-318 Page 8 Revision 2 Cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the following subsections. These limits have been developed using the NRC approved methodologies specified in Section 1.1.

2.1 Reactor Core Safety Limits (TS 2.1.1) 2.1.1 The Reactor Core Safety Limits are shown in Figure 1.

2.2 Shutdown Margin - SDM (TS 3.1.1, TS 3.1.4, TS 3.1.5, TS 3.1.6 and TS 3.1.8) 2.2.1 For TS 3.1.1, SDM shall be '.::.1.3% ~K/K in MODE 2 with k-eff < 1.0 and in MODES 3 and 4.

2.2.2 For TS 3.1.1, SDM shall be'.:'.:. 1.0% ~K/K in MODE 5.

2.2.3 For TS 3.1.4, SDM shall be '.::.1.3% ~K/K in MODES 1 and 2.

2.2.4 For TS 3.1.5, SDM shall be '.::.1.3% ~K/K in MODE 1 and MODE 2 with any control bank not fully inserted.

2.2.5 For TS 3.1.6, SDM shall be '.::.1.3% ~K/K in MODE 1 and MODE 2 with K-eff:::. 1.0.

2.2.6 For TS 3.1.8, SDM shall be '.::.1.3% ~K/K in MODE 2 during PHYSICS TESTS.

McGuire 2 Cycle 24 Core Operating Limits Report Figure 1 Reactor Core Safety Limits Four Loops in Operation MCEI-0400-318 Page 9 Revision 2 DO NOT OPERA TE IN THIS AREA 660 t------+-------1--------+

---t

~ 630 l------t------"'"""'-::--t----------11-----~=---------1-~----l Of)

~

t-c Cl)

~ 620 0.0 0.2 ACCEPTABLE OPERATION 0.4 0.6 0.8 1.0 1.2 Fraction of Rated Thermal Power

McGuire 2 Cycle 24 Core Operating Limits Report 2.3 Moderator Temperature Coefficient - MTC (TS 3.1.3) 2.3.l The Moderator Temperature Coefficient (MTC) Limits are:

MCEI-0400-318 Page 10 Revision 2 MTC shall be less positive than the upper limits shown in Figure 2. BOC, ARO, HZP MTC shall be less positive than 0.7E-04 LiKIK/°F.

EOC, ARO, RTP MTC shall be less negative than the -4.3E-04 ~°F lower MTC limit.

2.3.2 300 PPM MTC Surveillance Limit is:

Measured 300 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to -3.65E-04 Af(/K/°F.

2.3.3 The Revised Predicted near-EOC 300 PPM ARO RTP MTC shall be calculated using the procedure contained in DPC-NE-1007-PA If the Revised Predicted MTC is less negative than or equal to the 300 PPM SR 3.1.3.2 Surveillance Limit, and all benchmark data contained in the surveillance procedure is satisfied, then an MTC measurement in accordance with SR 3.1.3.2 is not required to be performed.

2.3.4 60 PPM MTC Surveillance Limit is:

60 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to

-4.125E-04 LiKIK/°F.

Where:

BOC = Beginning of Cycle (bumup corresponding to the most positive MTC)

EOC = End of Cycle ARO = All Rods Out HZP = Hot Zero Power R TP = Rated Thermal Power PPM = Parts per million (Boron) 2.4 Shutdown Bank Insertion Limit (TS 3.1.5) 2.4.1 Each shutdown bank shall be withdrawn to at least 222 steps. Shutdown banks are withdrawn in sequence and with no overlap.

2.5 Control Bank Insertion Limits (TS 3.1.6) 2.5.1 Control banks shall be within the insertion, sequence, and overlap limits shown in Figure 3. Specific control bank withdrawal and overlap limits as a function of the fully withdrawn position are shown in Table 1.

1.0 0.9 0.8

=

~

0.7

(,J

~

0 u~ 0.6

~ 0

~~ 0.5

~ <l 0.4

c. "':!"

89

~~ 0.3 oC

~

0.2

~

"C 0

0.1

~

0.0 McGuire 2 Cycle 24 Core Operating Limits Report Figure 2 MCEI-0400-318 Page 11 Revision 2 Moderator Temperature Coefficient Upper Limit Versus Power Level Unacceptable Operation Acceptable Operation 0

10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power NOTE: Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to OP/2/ A/6100/22 Unit 2 Data Book for details.

231 220 200

,-_ = 180

i
:

ell -

] 160

~ 140

g.

cu

~ 120

=

.s 100 c

~ 80

=

.s

..... - 60 cu

"' =

"O c 40

~

20 0

MCEI-0400-318 Page 12 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report Figure3 Control Bank Insertion Limits Versus Percent Rated Thermal Power Fully Withdrawn (Maximum= 23j~

~ - -

~

~ -

/

/

/

/

/

/

/

/

/

/

Fully Withdrawn

/

/

/

Control Bank B ~

(Min~mum = 222)

/

/

/

J I (100%, 161) !=

./

./

~ (0%, 163)

/

/

/

/

./

/

/

/

J

/

./

/

Control Bank C

/

/

/

./

/

/

J

/

/

/

/

/

./

/

/

Control Bank D

/

/

/

/

./

/

1=j *co%, 47) 1

/

/

J

~

] Fully Inserted

/

/

(30%, 0)

I

/

0 10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power The Rod Insertion Limits (RIL) for Control Bank D (CD), Control Bank C (CC), and Control Bank B (CB) can be calculated by:

Bank CD RIL = 2.3(P)- 69 {30<PS100}

Bank CC RIL = 2.3(P) +47

{O < P < 76.1} for CC RIL = 222{76.1<PS100}

Bank CB RIL = 2.3(P) + 163 {O < P < 25. 7} for CB RIL = 222 {25. 7 < P <JOO}

where P = %Rated Thermal Power NOTE:

Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to OP/2/ A/6100/22 Unit 2 Data Book for details.

McGuire 2 Cycle 24 Core Operating Limits Report Table 1 RCCA Withdrawal Steps and Sequence Fully Withdrawn at 222 Steps Control Control Control Control Bank A Bank B Bauk C Bank D 0 Start 116 222 Stop 222 222 222 222 0

0 Start 106 116 222 Stop 222 222 0

0 0

O Start 106 116 222 Stop 0

0 0

0 0

0 Start 106 Fully Withdrawn at 224 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 116 224 Stop 224 224 224 224 0

0 0 Start 0

108 0

116 O Start 224 Stop

!08 224 116 224 224 Stop 0

0 0

0 0

0 Start 108 Fully Withdrawn at 226 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

116 OStart 226 Stop 110 226 116 226 226 Stop 226 226 226 226 0

0 0

0 Start 110 116 226 Stop 0

0 0

0 0

0 Start 110 Fully Withdrawn at 228 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 116 228 Stop 228 228 228 228 0

0 Start 112 116 228 Stop 228 228 0

0 0

0 Start 112 116 228 Stop 0

0 0

0 0

0 Start 112 Fully Withdrawn at 230 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 230 Stop 114 0

0 230 116 0 Start 0

230 230 Stop 114 0

230 230 116 0 Start 230 230 230 Stop 114 Fully Withdrawn at 223 Steps Control Control BankA BankB 0 Start 116 223 Stop 223 223 223*

223 0

0 Start 107 116 223 Stop 223 223 Control BankC 0

0 0

O Start 107 116 223 Stop Control BankD 0

0 0

0 0

0 Start 107 Fully Withdrawn at 225 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 116 225 Stop 225 225 225 225 0

0 Start 109 116 225 Stop 225 225 0

0 0

0 Start 109 116 225 Stop 0

0 0

0 0

0 Start 109 Fully Withdrawn at 227 Steps Control Control BankA BankB 0 Start 116 227 Stop 227 227 227 227 0

0 Start Ill 116 227 Stop 227 227 Control BankC 0

0 0

0 Start 111 116 227 Stop Control BankD 0

0 0

0 0

0 Start Ill Fnlly Withdrawn at 229 Steps Control BankA 0 Start 116 229 Stop 229 229 229 229 Control BankB 0

0 Start 113 116 229 Stop 229 229 Control BankC 0

0 0

O Start 113 116 229 Stop Control BankD 0

0 0

0 0

0 Start 113 Fully Withdrawn at 231 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 231 Stop 115 0

o 231 116 0 Start o

231 231 Stop 115 o

231 231 116 0 Start 231 231 231Stop 115 MCEI-0400-318 Page 13 Revision 2

McGuire 2 Cycle 24 Core Operating Limits Report 2.6 Heat Flux Hot Channel Factor-FQ(X,Y,Z) (TS 3.2.1)

MCEI-0400-318 Page 14 Revision2 2.6.1 FQ(X, Y,Z) steady-state limits are defined by the following relationships:

where, F ~TP *K(Z)/P F ~TP *K(Z)/0.5 for P > 0.5 for P :S 0.5 P =(Thermal Power)/(Rated Power)*

Note: The measured FQ(X,Y,Z) shall be increased by 3% to account for manufacturing tolerances and 5% to account for measurement uncertainty when comparing against the LCO limits. The manufacturing tolerance and measurement uncertainty are implicitly included in the FQ surveillance limits as defined in Sections 2.6.5 and 2.6.6.

2.6.2 p~TP = 2.70 x K(BU) 2.6.3 K(Z) is the normalized FQ(X,Y,Z) as a function of core height. The K(Z) function for Westinghouse RFA fuel is provided in Figure 4.

2.6.4 K(BU) is the normalized F Q(X, Y,Z) as a function of bumup. F ~TP with the K(BU) penalty for Westinghouse RFA fuel is analytically confirmed in cycle-specific reload calculations. K(BU) is set to 1.0 at all bumups.

The following parameters are required for core monitoring per the Surveillance Requirements ofTechnical Specification 3.2.1:

L F~(X, Y,Z)

  • M9(X, Y,Z) 2.6.5 FQ(X,Y,Z)OP =

UMT *MT* TILT

where:

MCEI-0400-318 Page 15 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report F~ (X,Y,Z)OP =

Cycle dependent maximum allowable design peaking factor that ensures FQ(X,Y,Z) LOCA limit will be preserved for operation within the LCO limits. F~ (X,Y,z)OP includes allowances for calculation and measurement uncertainties.

Ft(X,Y,Z)

MQ(X,Y,Z)

UMT MT TILT Design power distribution for FQ. Ft (X,1:'",Z) is provided in Appendix Table A-1 for normal operating conditions, and in Appendix Table A-4 for power escalation testing during initial startup operation.

Margin remaining in core location X,Y,Z to the LOCA limit in the transient power distribution. MQ(X,Y,Z) is provided in Appendix Table A-1 for normal operating conditions and in Appendix Table A-4 for power escalation testing during initial startup operation.

Total Peak Measurement Uncertainty. (UMT = 1.05)

Engineering Hot Channel Factor. (MT= 1.03)

Peaking penalty to account for allowable quadrant power tilt ratio of 1.02. (TILT= 1.035)

L RPS 2.6.6 FQ(X,Y,Z)

=

F~(X,Y,Z)

  • Mc(X,Y,Z)

UMT *MT* TILT where:

Ft(X,Y,Z)RPS =

Cycle dependent maximum allowable design peaking factor that ensures the FQ(X,Y,Z) Centerline Fuel Melt (CFM) limit will be preserved for operation within the LCO limits.

Ft(X,Y,Z)RPS includes allowances for calculation and measurement uncertainties.

D FQ(X,Y,Z)

Defined in Section 2.6.5.

McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page 16 Revision 2 Mc(X,Y,Z) = Margin remaining to the CFM limit in core location X,Y,Z from the transient power distribution. Mc(X,Y,Z) is provided in Appendix Table A-2 for normal operating conditions and in Appendix Table A-5 for power escalation testing during initial startup operation.

UMT Defined in Section 2.6.5.

MT Defined in Section 2.6.5.

TILT Defined in Section 2.6.5.

2.6.7 KSLOPE = 0.0725 where:

KSLOPE is the adjustment to K1 value from the OT~T trip setpoint required to RPS compensate for each 1 % that F/; (X,Y,Z) exceeds F~ (X,Y,Z) 2.6.8 FQ(X,Y,Z) penalty factors for Technical Specification Surveillances 3.2.1.2 and 3.2.1.3 are provided in Table 2.

MCEI-0400-318 Page 17 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report Figure 4 K(Z), Normalized FQ(X,Y,Z) as a Function of Core Height for Westinghouse RFA Fuel 1.200 ~--------------------------~

(0.0, 1.00)

(4.0, 1.00) i.ooo.,_ ________...

1 0.800 g 0.600

~

0.400 0.200 Core Heii:;ht (ft}

0.0

S4.0

>4.0 12.0 (4.0, 0.9259)

K(Z}

1.0 1.0 0.9259 0.9259 (12.0, 0.9259) 0.000 +------+------+-----+------+-----+--------<

0.0 2.0 4.0 6.0 8.0 10.0 12.0 Core Height (ft)

McGuire 2 Cycle 24 Core Operating Limits Report Table 2 FQ(X,Y,Z) and F AfI{X,Y) Penalty Factors MCEI-0400-318 Page 18 Revision 2 For _Technical Specification Surveillance's 3.2.1.2, 3.2.1.3 and 3.2.2.2 Burn up FQ(X,Y,Z)

FLrn(X,Y)

(EFPD)

Penalty Factor (%)

Penalty Factor(%)

0 2.00 2.00 4

2.00 2.00 12 2.51 2.00 25 2.21 2.00 50 2.00 2.00 75 2.00 2.00 100 2.00 2.00 125 2.00 2.00 150 2.00 2.00 175 2.00 2.00 200 2.00 2.00 225 2.00 2.00 250 2.00 2.00 275 2.00 2.00 300 2.00 2.00 325 2.00 2.00 350 2.00 2.00 375 2.00 2.00 400 2.00 2.00 425 2.00 2.00 450 2.00 2.00 465 2.00 2.00 475 2.00 2.00 496 2.00 2.00 511 2.00 2.00 521 2.00 2.00 531 2.00 2.00 Note: Linear interpolation is adequate for intermediate cycle burnups. All cycle burnups outside of the range of the table shall use a 2% penalty factor for both FQ(X,Y,Z) and F ~H(X,Y) for compliance with the Technical Specification Surveillances 3.2.1.2, 3.2.1.3 and 3.2.2.2.

McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page 19 Revision 2 2.7 Nuclear Enthalpy Rise Hot Channel Factor - F MJ(X,Y) (TS 3.2.2)

F ~H steady-state limits referred to in Technical Specification 3.2.2 is defined by the following relationship.

2.7.1 Fltt(X, Y)LCO= MARP (X,Y) * [ 1.0 + ~

  • (1.0 - P)J where:

FkH (X, Y)Lco is the steady-state, maximum allowed radial peak and includes allowances for calculation/measurement uncertainty.

MARP(X,Y) = Cycle-specific operating limit Maximum Allowable Radial Peaks. MARP(X,Y) radial peaking limits are provided in Table 3.

Thermal Power p = ~~~~~,....-~-

Rated Thermal Power RRH = Thermal Power reduction required to compensate for each 1 % that the measured radial peak, F~ (X,Y), exceeds its limit. RRH also is used to scale the MARP limits as a function of power per the FkH (X, Y) Leo equation. (RRH = 3.34 (0.0 < P ~ 1.0))

The following parameters are required for core monitoring per the surveillance requirements of Technical Specification 3.2.2.

2.7.2 L

SURV -

FfH (X, Y) x M iiH (X, Y)

F iiH (X, Y)

-="-------"'"-'----

UMR x TILT where:

L SURV _

F8H (X,Y)

Cycle dependent maximum allowable design peaking factor that ensures the F 8 H(X, Y) limit will be preserved for operation within the LCO limits. FkH (X,Y)suRv includes allowances for calculation/measurement uncertainty.

MCEI-0400-318 Page 20 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report F~H (X,Y) = Design radial power distribution for Fm* F~H (X,Y) is provided in Appendix Table A-3 for normal operation and in Appendix Table A-6 for power escalation testing during initial startup operation.

M11H(X, Y) =The margin remaining in core location X, Y relative to the Operational DNB limits in the transient power distribution.

Mm(X,Y) is provided in Appendix Table A-3 for normal operation and in Appendix Table A-6 for power escalation testing during initial startup operation.

UMR =Uncertainty value for measured radial peaks (UMR = 1.0).

UMR is 1.0 since a factor of 1.04 is implicitly included in the variable M1m(X,Y).

TILT = Peaking penalty to account for allowable quadrant power tilt ratio of 1.02 (TILT= 1.035).

2.7.3 RRH is defined in Section 2.7.1.

2.7.4 TRH=0.04 where:

TRH =Reduction in the OT Ll T K 1 setpoint required to compensate for each 1 %

that the measured radial peak, F~ (X,Y) exceeds its limit.

2.7.5 F~H (X,Y) penalty factors for Technical Specification Surveillance 3.2.2.2 are provided in Table 2.

2.8 Axial Flux Difference - AFD (TS 3.2.3) 2.8.1 The Axial Flux Difference (AFD) Limits are provided in Figure 5.

Core Ht (ft.)

1.05 1.2 0.12 1.8092 1.8553 1.9248 1.2 1.8102 1.8540 1.9248 2.4 1.8093 1.8525 1.9312 3.6 1.8098 1.8514 1.9204 4.8 1.8097 1.8514 1.9058 6.0 1.8097 1.8514 1.8921 7.2 1.8070 1.8438 1.8716 8.4 1.8073 1.8319 1.8452 9.6 1.8072 1.8102 1.8093 10.8 1.7980 1.7868 1.7611 11.4 1.7892 1.7652 1.7250 McGuire 2 Cycle 24 Core Operating Limits Report Table 3 Maximum Allowable Radial Peaks (MARPS)

RFAMARPS Axial Peak 1.3 1.4 1.5 1.6 1.7 1.8 1.9146 1.9179 2.0621 2.0498 2:0090 1.9333 1.9146 1.9179 2.1073 2.0191 1.9775 1.9009 1.9146 1.9179 2.0735 1.9953 1.9519 1.8760 1.9146 1.9179 2.0495 1.9656 1.9258 1.8524 1.9146 1.9179 2.0059 1.9441 1.9233 1.8538 1.9212 1.9179 1.9336 1.8798 1.8625 1.8024 1.8930 1.8872 1.8723 1.8094 1.7866 1.7332 1.8571 1.8156 1.7950 1.7359 1.7089 1.6544 1.7913 1.7375 1.7182 1.6572 1.6347 1.5808 1.7163 1.6538 1.6315 1.5743 1.5573 1.5088 1.6645 1.6057 1.5826 1.5289 1.5098 1.4637 1.9 1.8625 1.8306 1.8054 1.7855 1.7836 1.7472 1.6812 1.6010 1.5301 1.4624 1.4218 MCEI-0400-318 Page 21 Revision 2 2.1 3.0 1.7780 1.3151 1.7852 1.3007 1.7320 1.4633 1.6996 1.4675 1.6714 1.2987 1.6705 1.3293 1.5982 1.2871 1.5127 1.2182 1.4444 1.1431 1.3832 1.1009 1.3458 1.0670 3.25 1.2461 1.2235 1.4616 1.3874 1.2579 1.2602 1.2195 1.1578 1.0914 1.0470 1.0142

-50 MCEI-0400-318 Page 22 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report Figure 5 Percent of Rated Thermal Power Versus Percent Axial Flux Difference Limits

(-18, 100)

(+10, 100)

Unacceptable Operation 90 Unacceptable Operation 80 Acceptable Operation 70 60 50

(-36, 50)

(+21, 50) 40 30 20 10

-40

-30

-20

-10 0

10 20 30 40 50 Axial Flux Difference (% Delta I)

NOTE: Compliance with Technical Specification 3.2.l may require more restrictive AFD limits. Refer to OP/2/A/6100/22 Unit 2 Data Book for more details.

McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page 23 Revision 2 2.9 Reactor Trip System Instrumentation Setpoints (TS 3.3.1) Table 3.3.1-1 2.9.l Overtemperature AT Setpoint Parameter Values Parameter Nominal Tavg at RTP Nominal RCS Operating Pressure Overtemperature Ii T reactor trip setpoint Ove11emperature /j.T reactor trip heatup setpoint penalty coefficient Overtemperature /j. T reactor trip depressurization setpoint penalty coefficient Time constants utilized in the lead-lag compensator for !iT Time constant utilized in the lag compensator for Ii T Time constants utilized in the lead-lag compensator for Tavg Time constant utilized in the measured T avg lag compensator f1 (/j.I) "positive" breakpoint f 1 (/j.I) "negative" breakpoint fi (/j.I) "positive" slope f 1 (/j.I) "negative" slope T'.:S 585.1°F P' = 2235 psig Kl.:S 1.1978 K2 = 0.03341°F K3 = 0.001601/psi

't 1 ::::: 8 sec.

't2 _:::: 3 sec.

't3 :::; 2 sec.

't4::::: 28 sec.

'tS _:::: 4 sec.

't6 :::; 2 sec.

= 19.0 %/j.I

=NIA*

=NIA*

The f1 (M) "negative" breakpoint and the fi (M) "negative" slope are less restrictive than the OP/j.T f1(!1I) negative breakpoint and slope. Therefore, during a transient which challenges the negative imbalance limits, the OP Ii T f1(/j.I) limits will result in a reactor trip before the OT Ii T fi (M) limits are reached. This makes implementation of the OT/j.T fi (M) negative breakpoint and slope unnecessary.

MCEI-0400-318 Page 24 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report 2.9.2 Overpower AT Setpoint Parameter Values Parameter Nominal Tavg at RTP Overpower !ff reactor trip setpoint Overpower ~ T reactor trip Penalty Overpower ~T reactor trip heatup setpoint penalty coefficient Time constants utilized in the lead-lag compensator for ~ T Time constant utilized in the lag compensator for ~T Time constant utilized in the measured Tavg lag compensator Time constant utilized in the rate-lag controller for Tavg fi(M) "positive" breakpoint fi(M) "negative" breakpoint f2(M) "positive" slope fi(M) "negative" slope T" :S 585.1°F Ks= 0.02/°F for ~ncreasing Tavg Ks= 0.0 for decreasing Tavg K6 = 0.001179/°F for T > T" K6 = 0.0 for T :ST"

  • i :'.".: 8 sec.
  • 2 :=: 3 sec.
  • 3 ::: 2 sec.
  • 6 :=: 2 sec.
  • 7 :'.".: 5 sec.

= 35.0 %~I

=-35.0 %M

= 7.0 %~Tof %~I

= 7.0 %~T0/ %~I

McGuire 2 Cycle 24 Core Operating Limits Report 2.10. RCS Pressure, Temperature and Flow Limits for DNB (TS 3.4.1)

MCEI-0400-318 Page 25 Revision 2 2.10.1 RCS pressure, temperature and flow limits for DNB are shown in Table 4.

2.11 Accumulators (TS 3.5.1) 2.11.1 Boron concentration limits during MODES 1 and 2, and MODE 3 with RCS pressure > 1000 psi:

Parameter Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator minimum boron concentration.

Accumulator maximum boron concentration.

Applicable Burnup 0 -200 EFPD 200.1 - 250 EFPD 250.1 - 300 EFPD 300.1 - 350 EFPD 350.1 - 400 EFPD 400.1 - 450 EFPD 450. l - 465 EFPD 465.1 - 521 EFPD 521.1 - 531 EFPD 0- 531 EFPD 2.12 Refueling Water Storage Tank - RWST (TS 3.5.4) 2.12.1 Boron concentration limits during MODES 1, 2, 3, and 4:

Parameter R WST minimum boron concentration.

R WST maximum boron concentration.

Limit 2,475 ppm 2,475 ppm 2,398 ppm 2,292 ppm 2,214 ppm 2,143 ppm 2,077 ppm 2,057 ppm 1,972 ppm 2,875 ppm Limit 2,675 ppm 2,875 ppm

McGuire 2 Cycle 24 Core Operating Limits Report Table 4 Reactor Coolant System DNB Parameters No. Operable Parameter Indication Channels

1. Indicated RCS Average Temperature meter 4

meter 3

computer 4

computer 3

2. Indicated Pressurizer Pressure meter 4

meter 3

computer 4

computer 3

3. RCS Total Flow Rate MCEI-0400-318 Page 26 Revision 2 Limits
S 587.2 °F
S 586.9 °F
S 587.7 °F
S 587.5 °F
2212.3 psig
2215.0 psig
2209.1 psig
2211.3 psig
388,000 gpm

McGuire 2 Cycle 24 Core Operating Limits Report 2.13 Spent Fuel Pool Boron Concentration (TS 3.7.14)

MCEI-0400-318 Page 27 Revision 2 2.13.1 Minimum boron concentration limit for the spent fuel pool. Applicable when fuel assemblies are stored in the spent fuel pool.

Parameter Spent fuel pool minimum boron concentration.

2,675 ppm 2.14 Refueling Operations - Boron Concentration (TS 3.9.1) 2.14.1 Minimum boron concentration limit for the filled portions of the Reactor Coolant System, refueling canal, and refueling cavity for MODE 6 conditions. The minimum boron concentration limit and plant refueling procedures ensure that core Keff remains within MODE 6 reactivity requirement of Keff.::::: 0.95.

Parameter Minimum boron concentration of the Reactor Coolant System, the refueling canal, and the refueling cavity.

2,675 ppm

MCEl-0400-318 Page 28 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report 2.15 Borated Water Source - Shutdown (SLC 16.9.14) 2.15.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during MODE 4 with any RCS cold leg temperature.:S 300 °F and MODES 5 and 6.

Parameter Note: When cycle burnup is > 476 EFPD, Figure 6 may be used to determine required BAT minimum level.

BAT minimum contained borated water volume BAT minimum boron concentration BAT minimum water volume required to maintain SDM at 7,000 ppm RWST minimum contained borated water volume RWST minimum boron concentration RWST minimum water volume required to maintain SDM at 2,675 ppm 10,599 gallons 13.6% Level 7,000 ppm 2,300 gallons 47,700 gallons 41 inches 2,675 ppm 8,200 gallons

MCEI-0400-318 Page 29 Revision 2 McGuire 2 Cycle 24 Core Operating Limits Report 2.16 Borated Water Source - Operating (SLC 16.9.11) 2.16.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during MODES I, 2, 3, and MODE 4 with all RCS cold leg temperature> 300 °F.

Parameter Note: When cycle burnup is > 476 EFPD, Figure 6 may be used to determine required BAT minimum level.

BAT minimum contained borated water volume BAT minimum boron concentration BAT minimum water volume required to maintain SDM at 7,000 ppm R WST minimum contained borated water volume RWST minimum boron concentration RWST maximum boron concentration (TS 3.5.4)

RWST minimum water volume required to maintain SDM at 2,675 ppm 2.17 Standby Shutdown System - (SLC-16.9.7) 22,049 gallons 38.0% Level 7,000 ppm 13,750 gallons 96,607 gallons 103.6 inches 2,675 ppm 2,875 ppm 57, 107 gallons 2.17.1 Minimum boron concentration limit for the spent fuel pool required for Standby Makeup Pump Water Supply. Applicable for MODES 1, 2, and 3.

Parameter Spent fuel pool minimum boron concentration for TR 16.9.7.2.

2,675 ppm

McGuire 2 Cycle 24 Core Operating Limits Report Figure 6 Boric Acid Storage Tank Indicated Level Versus RCS Boron Concentration (Valid When Cycle Burnup is> 476 EFPD)

MCEI-0400-318 Page 30 Revision 2 This figure includes additional volumes listed in SLC 16.9.14 and 16.9.11 40.0,-----------------------~--.,-------------,

35.0 30.0 I

Acceptable 10.0 I Unacceptable Operation I 5.0 j

RCS Boron Concentration BAT Level (ppm)

(%level) 0 < 300 37.0 300 < 500 33.0 500 < 700 28.0 700 < 1000 23.0.

1000 < 1300 1~

~ 1300 8.7 O.O-t-------;---.----~----r--.---~--r---~----r--.---~--r---~---1 0

200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 RCS Boron Concentration (ppmb)

McGuire 2 Cycle 24 Core Operating Limits Report MCEI-0400-318 Page 31 Revision 2 NOTE: Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. This data was generated in the McGuire 2 Cycle 24 Maneuvering Analysis calculation file, MCC-1553.05-00-0613. Due to the size of the monitoring factor data, Appendix A is controlled electronically within Duke and is not included in the Duke internal copies of the COLR. The Plant Nuclear Engineering Section will control this information via computer file(s) and should be contacted if there :is a need to access this information.

Appendix A is included in the COLR copy transmitted to the NRC.