December 18, 2014 Dr. Jeffrey Geuther, Director Nuclear Reactor Facility Manager Kansas State University 112 Ward Hall Manhattan, KS 66506-2500

SUBJECT:

EXAMINATION REPORT NO. 50-188/OL-15-01, KANSAS STATE UNIVERSITY

Dear Dr. Geuther:

During the week of December 1, 2014, the U.S. Nuclear Regulatory Commission (NRC) administered operator licensing examinations at your Kansas State University TRIGA Reactor.

The examinations were conducted according to NUREG-1478, Operator Licensing Examiner Standards for Research and Test Reactors, Revision 2. Examination questions and preliminary findings were discussed at the conclusion of the examination with those members of your staff identified in the enclosed report.

In accordance with Section 2.390 of Title 10 of the Code of Federal Regulations, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. If you have any questions concerning this examination, please contact Mr. John T. Nguyen at (301) 415-4007 or via email John.Nguyen@nrc.gov.

Sincerely,

/RA/

Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-188

Enclosures:

1. Examination Report No. 50-188/OL-15-01
2. Facility Comments with NRC Resolution
3. Written examination with facility comments incorporated cc w/o enclosures: See next page

ML14345A687 OFFICE NRR/DPR/PROB NRR/DPR/PROB NRR/DPR/PROB NAME JNguyen CRevelle KHsueh DATE 12/11/2014 12/16/2014 12/18/2014

Kansas State University Docket No. 50-188 cc:

Office of the Governor State of Kansas Suite 2415 300 SW 10th Avenue Topeka, KS 66612-1590 Thomas A. Conley, RRPJ, CHP Section Chief Radiation and Asbestos Control KS Dept of Health & Environment 1000 SW Jackson, Suite 330 Topeka, KS 66612-1365 Mayor of Manhattan P.O. Box 748 Manhattan, KS 66502 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

ENCLOSURE 1 U. S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.:

50-188/OL-15-01 FACILITY DOCKET NO.:

50-188 FACILITY LICENSE NO.:

R-88 FACILITY:

Kansas State University EXAMINATION DATES:

December 01 - December 03, 2014 SUBMITTED BY:

_________/RA/_________________

____12/11/2014___

John Nguyen, Chief Examiner Date

SUMMARY

During the week of December 1, 2014, the NRC administered operator licensing examination to two Senior Reactor Operator - Upgrade (SROU), two new Reactor Operator (RO), and one RO-Retake license candidates. One RO failed the Section B of the written examination; other license candidates passed all applicable portions of the examinations.

REPORT DETAILS

1.

Examiners:

John Nguyen, Chief Examiner, NRC

2.

Results:

RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 2/1 0/0 2/1 Operating Tests 2/0 2/0 4/0 Overall 2/1 2/0 4/1

3.

Exit Meeting:

Jeffrey Geuther, Reactor Director, KSU Michele DeSouza, Reactor Engineer, NRC John Nguyen, Chief Examiner, NRC At the conclusion of the site visit, the examiner met with representative of the facility staff to discuss the results of the examinations.

ENCLOSURE 2 FACILITY COMMENTS ON THE WRITTEN EXAM WITH NRC RESOLUTION QUESTION A.15 Facility comments:

The question gives source strength S0 of 300 neutrons / sec, and a subcritical multiplication factor M of 0.7. Based on this information, the observed source strength should be S = S0 M = 210 neutrons / sec. (See for example DOE Fundamentals Handbook on Nuclear Physics and Reactor Theory, DOE-HDBK-1019/2-93, Module 4, Eq. 4-2). The intent of the question seems to be that the effective multiplication factor k

= 0.7, which would result in S = 1/(1-0.7)

  • 300 = 1000 neutrons / sec. However, by solving the problem as written, (not as was intended to be written), the calculated result is 210 neutrons / sec, which corresponds to answer (a).

Facility Recommendation:

Therefore the Facility recommends that the correct answer be changed from (b) to (a).

NRC Resolution:

The NRC agrees with the facility comment and the correct answer is (a).

QUESTION B.14 Facility comments:

The question asks what action must be taken if, during a fuel inspection, a fuel element is found to be deformed by 1/8 (0.125). According to Tech Specs 3.7.3(2), Fuel elements in the reactor core shall not be laterally bent by more than 1/8 in. Therefore, strictly speaking, a lateral bend of 0.125 would be permissible, but any greater bend would not be permissible.

Facility Recommendation:

Therefore the Facility recommends that the correct answer be changed from (c) to (a).

NRC Resolution:

The NRC agrees with the facility comment and the correct answer is (a).

QUESTION C.12 Facility comments:

In this problem, it is stated that the reactor is operated at an indicated power of 100 kWh, and that the temperature increased by 6°C in one hour. Based on the constant of 0.0526°C / kWh, the true power is calculated to be 114 kW. Based on this calculation, the indicated power is too low, and the detector must be lowered into the flux peak to match the true power of 114 kW (answer (b)). In the answer key, the correct answer is given as (a), that the detector must be raised to perform the calibration. The justification in the answer key is that the true power is 100 kW, and that the indicated power is 114 kW. It appears that these two numbers were reversed when creating the answer sheet.

It is clear that the indicated power is lower than the true power based on the calorimetric calculation.

Facility Recommendation:

Therefore the Facility recommends that the correct answer be changed from (a) to (b).

NRC Resolution:

The NRC agrees with the facility comment and the correct answer is (b).

ENCLOSURE 3 U. S. NUCLEAR REGULATORY COMMISSION NON-POWER REACTOR LICENSE EXAMINATION FACILITY:

KANSAS REACTOR TYPE:

TRIGA DATE ADMINISTERED:

December 3, 2014 CANDIDATE:

INSTRUCTIONS TO CANDIDATE:

Answers are to be written on the Answer sheet provided. Attach all Answer sheets to the examination. Point values are indicated in parentheses for each question. A 70% in each category is required to pass the examination. Examinations will be picked up three (3) hours after the examination starts.

% OF CATEGORY % OF CANDIDATE'S CATEGORY VALUE TOTAL SCORE VALUE CATEGORY 20.00 33.3 A. REACTOR THEORY, THERMODYNAMICS AND FACILITY OPERATING CHARACTERISTICS 20.00 33.3 B. NORMAL AND EMERGENCY OPERATING PROCEDURES AND RADIOLOGICAL CONTROLS 20.00 33.3 C. FACILITY AND RADIATION MONITORING SYSTEMS 60.00 % TOTALS FINAL GRADE All work done on this examination is my own. I have neither given nor received aid.

Candidate's Signature ENCLOSURE 2 A. RX THEORY, THERMO & FAC OP CHARS A N S W E R S H E E T Multiple Choice (Circle or X your choice)

If you change your Answer, write your selection in the blank.

A01 a b c d ___

A02 a b c d ___

A03 a b c d ___

A04 a b c d ___

A05 a b c d ___

A06 a b c d ___

A07 a b c d ___

A08 a b c d ___

A09 a b c d ___

A10 a b c d ___

A11 a b c d ___

A12 a b c d ___

A13 a b c d ___

A14 a b c d ___

A15 a b c d ___

A16 a b c d ___

A17 a b c d ___

A18 a b c d ___

A19 a b c d ___

A20 a b c d ___

(***** END OF CATEGORY A *****)

B. NORMAL/EMERG PROCEDURES & RAD CON A N S W E R S H E E T Multiple Choice (Circle or X your choice)

If you change your Answer, write your selection in the blank.

B01 a b c d ___

B02 a b c d ___

B03 a ___ b ___ c ___ d ___ (0.25 each)

B04 a b c d ___

B05 a b c d ___

B06 a b c d ___

B07 a b c d ___

B08 a b c d ___

B09 a b c d ___

B10 a b c d ___

B11 a b c d ___

B12 a b c d ___

B13 a b c d ___

B14 a b c d ___

B15 a b c d ___

B16 a b c d ___

B17 a b c d ___

B18 a b c d ___

B19 a b c d ___

B20 a b c d ___

(***** END OF CATEGORY B *****)

C. PLANT AND RAD MONITORING SYSTEMS A N S W E R S H E E T Multiple Choice (Circle or X your choice)

If you change your Answer, write your selection in the blank.

C01 a b c d ___

C02 a b c d ___

C03 a b c d ___

C04 a b c d ___

C05 a b c d ___

C06 a b c d ___

C07 a b c d ___

C08 a ___ b ___ c ___ d ___ (0.50 each)

C09 a b c d ___

C10 a b c d ___

C11 a b c d ___

C12 a b c d ___

C13 a b c d ___

C14 a b c d ___

C15 a ___ b ___ c ___ (0.33 each)

C16 a b c d ___

C17 a b c d ___

C18 a b c d ___

C19 a b c d ___

(***** END OF CATEGORY C *****)

(********** END OF EXAMINATION **********)

NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:

1.

Cheating on the examination means an automatic denial of your application and could result in more severe penalties.

2.

After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have neither received nor given assistance in completing the examination. This must be done after you complete the examination.

3.

Restroom trips are to be limited and only one candidate at a time may leave. You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.

4.

Use black ink or dark pencil only to facilitate legible reproductions.

5.

Print your name in the blank provided in the upper right-hand corner of the examination cover sheet and each Answer sheet.

6.

Mark your Answers on the Answer sheet provided. USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.

7.

The point value for each question is indicated in [brackets] after the question.

8.

If the intent of a question is unclear, ask questions of the examiner only.

9.

When turning in your examination, assemble the completed examination with examination questions, examination aids and Answer sheets. In addition turn in all scrap paper.

10.

Ensure all information you wish to have evaluated as part of your Answer is on your Answer sheet. Scrap paper will be disposed of immediately following the examination.

11.

To pass the examination you must achieve a grade of 70 percent or greater in each category.

12.

There is a time limit of three (3) hours for completion of the examination.

EQUATION SHEET DR - Rem, Ci - curies, E - Mev, R - feet 1 Curie = 3.7 x 1010 dis/sec 1 kg = 2.21 lbm 1 Horsepower = 2.54 x 103 BTU/hr 1 Mw = 3.41 x 106 BTU/hr 1 BTU = 778 ft-lbf

°F = 9/5 °C + 32 1 gal (H2O) 8 lbm

°C = 5/9 (°F - 32) cP = 1.0 BTU/hr/lbm/°F cp = 1 cal/sec/gm/°C

(

)

(

)

2 2

max

=

P 1

sec 1.0

=

eff

=

te P

P 0

eff K

S S

SCR

=

1

sec 10 1

4

x

=

+

=

eff SUR 06 26

(

)

(

)

2 1

1 1

2 1

eff eff K

CR K

CR

=

(

)

(

)

2 2

1 1

=

CR CR 2

1 1

1 eff eff K

K M

=

1 2

1 1

CR CR K

M eff

=

=

)

(

0 10 t

SUR P

P=

(

)

0 1

P P

=

eff eff K

K SDM

=1

=

+

=

eff 2

1 1

2 eff eff eff eff K

K K

K

=

693

.0 2

1 =

T eff eff K

K 1

=

t e

DR DR

=

0

( )

2 6

R n

E Ci DR=

2 2

2 2

1 1

d DR d

DR

=

(

)

(

)

1 2

1 2

2 2

Peak Peak

=

T UA H

m T

c m

Q P

=

=

=

ENCLOSURE 2 Kansas State University Operator Licensing Examination Week of December 01, 2014

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics QUESTION A.01

[1.0 point]

In a just critical reactor, the reactor operator immediately inserts a rabbit of $0.50 reactivity worth into the core. This insertion will cause:

Given:

T: reactor period, *: Prompt neutron lifetime; : reactivity insertion; : beta fraction; -eff:

delayed neutron precursor constant

a. A sudden drop in delayed neutrons
b. A number of prompt neutrons is twice as much as a number of delayed neutrons
c. The resultant period is a function of the prompt neutron lifetime (T=*/)
d. The resultant period is a function of the delayed neutron precursors QUESTION A.02

[1.0 point]

Reactor is increasing power from 10 W to 10 kW in the Steady State Mode. Which ONE of the following best describes the values of Keff and during the power increment?

a. Keff < 1 and 0< < 1
b. Keff = 1 and = 0
c. Keff > 1 and 0 < < -eff
d. Keff > 1 and -eff < < 1 QUESTION A.03

[1.0 point]

Few minutes following a reactor scram at full power, the reactor period has stabilized and the power level is decreasing at a CONSTANT rate. Reactor power is decreasing at time t = 10 kW, what will it be one minute later from 10 kW?

a. 0.2 kW
b. 4.7 kW
c. 7.5 kW
d. 21 kW

=

eff

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics QUESTION A.04

[1.0 point]

The MAJOR source of energy released during fission comes from:

a. Fission neutrons
b. Fission fragments
c. Prompt gamma rays
d. Fission product gamma decay QUESTION A.05

[1.0 point]

Reactor A with a Keff of 0.1 and reactor B with a Keff of 0.8, Keff is increased by 0.1 for each reactor. The amount of reactivity added in reactor A is ______ in reactor B for the same increment.

a. less than
b. same
c. eight times
d. thirty-six times QUESTION A.06

[1.0 point]

Which ONE of the following correctly describes the SIX-FACTOR FORMULA?

a. K = Keff
  • the utilization factor
b. K = Keff
  • the total leakage probability
c. Keff = K
  • the total non-leakage probability
d. Keff = K * (the resonance escape probability
  • the reproduction factor)

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics QUESTION A.07

[1.0 point]

Which ONE of the following describes the term PROMPT JUMP?

a. A reactor is subcritical at negative 80-second period
b. A reactor has attained criticality on prompt neutrons alone
c. The instantaneous change in power level due to inserting a control rod
d. The instantaneous change in power level due to withdrawing a control rod QUESTION A.08

[1.0 point]

Given the associated graph, which of the following answers best describe the neutron behavior within Region II?

a. The neutron cross section is inversely proportional to the neutron velocity (1/V)
b. The neutron cross section decreases steadily with increasing neutron energy (1/E)
c. Neutrons of specific energy levels (e.g., 50 ev, 100 kev) have more likely leakage from the reactor core
d. Neutrons of specific energy levels (e.g., 50 ev, 100 kev) are more likely to be absorbed than neutrons at other energy levels

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics QUESTION A.09

[1.0 point]

Which ONE of the following is a number of neutrons in the tritium nucleus (1T3 or 1 H3 )?

a. 1
b.
b. 2
c. 3
d. 4 QUESTION A.10

[1.0 point]

You are the reactor operator performing two pulsing operations. The first pulse has a reactivity worth of $1.20 which results in a peak power of 200 MW. If the second pulse has a reactivity worth of $2.00, the corresponding peak power is:

Given:

=0.0070

a. 1000 MW
b. 1750 MW
c. 2500 MW
d. 5000 MW QUESTION A.11 [1.0 point]

The reactor is on a CONSTANT positive period. Which ONE of the following power changes will take the longest time to complete?

a. 5%, from 95% to 100%
b. 10%, from 80% to 90%
c. 15%, from 15% to 30%
d. 20%, from 60% to 80%

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics QUESTION A.12

[1.0 point]

Delayed neutrons are produced by:

a. decay of Ar-41
b. Photoelectric Effect
c. decay of fission fragments
d. directly from the fission process QUESTION A.13

[1.0 point]

Which ONE of the following is the MAIN reason for operating reactor with thermal neutrons instead of fast neutrons?

a. The atomic weight of thermal neutrons is larger than fast neutrons, so thermal neutrons are easily to slow down and be captured by the fuel.
b. The neutron lifetime of thermal neutrons is longer than fast neutrons, so the fuel has enough time to capture thermal neutrons.
c. Fast neutrons give off higher radiation than thermal neutrons. Reactor needs to reduce radiation limit by using thermal neutrons.
d. The fission cross section of the fuel is much higher for thermal energy neutrons than fast neutrons.

QUESTION A.14

[1.0 point]

A reactor is subcritical with Keff of 0.955. Which ONE of the following is the MINIMUM reactivity (DK/K) that must be added to PROMPT criticality? Given eff=0.007

a. 0.0045
b. 0.0047
c. 0.0540
d. 0.1000

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics QUESTION A.15

[1.0 point]

Given a source strength of 300 neutrons per second (N/sec) and a subcritical multiplication factor, M, of 0.7, which ONE of the following is the expected stable neutron count rate?

a. 210 N/sec
b. 1000 N/sec
c. 2100 N/sec
d. 2500 N/sec QUESTION A.16

[1.0 point]

Which ONE of the following nuclides will cause a fast neutron to lose its most energy per collision?

a. H-1
b. B-10
c. C-12
d. U-235 QUESTION A.17

[1.0 point]

Two common FISSION PRODUCTS that have especially large neutron capture cross sections and play a significant role in reactor physics. One is Sm-149 and the other is:

a. B-10
b. Ar-41
c. Xe-135
d. Cs-137

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics QUESTION A.18

[1.0 point]

Reactor is at 100 % power. The following graph shows the reactor time behavior following a reactor scram. Which ONE of the following best describes the transition of power between point A and B after the initial insertion?.

a. An immediate decrease in the prompt neutron fraction due to leakage, absorption, and a reduction in the fission rate
b. Fission product gases such as xenon begin to buildup causing the expansion of fuel density
c. The longest lived delayed neutron precursor begins to effect
d. The short lived delayed neutron precursors begin to effect

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics QUESTION A.19 [1.0 point]

Section A - Reactor Theory, Thermohydraulics & Fac. Operating Characteristics Which ONE of the following physical characteristics of the TRIGA fuel is the main contributor for the prompt negative temperature coefficient?

a. As the fuel heats up the resonance absorption peaks broaden and increases the likelihood of neutron absorption in U-238
b. As the fuel heats up a rapid increase in moderator temperature occurs through conduction and convection heat transfer mechanisms which adds negative reactivity
c. As the fuel heats up fission product poisons (e.g., Xe) increase in concentration within the fuel matrix and add negative reactivity via neutron absorption
d. As the fuel heats up the oscillating hydrogen in the ZrH lattice imparts energy to a thermal neutron, thereby increasing its mean free path and probability of escape QUESTION A.20

[1.0 point, 0.25 each]

Which ONE of the following factors in the six factor formula is the MOST affected by the MODERATOR?

a. Fast fission factor
b. Reproduction factor
c. Thermal utilization factor
d. Resonance escape probability
                                  • End of Section A *****************

Section B - Normal/Emergency Procedures and Radiological Controls QUESTION B.01

[1.0 point]

Per KSU Emergency Classification, abnormal loss of shielding water from the reactor tank at a rate exceeding makeup capabilities is an example of:

a. Non-Classified Events
b. Medical Incident
c. Unusual Events
d. Alert QUESTION B.02

[1.0 point]

The reactor is in a SHUTDOWN condition, as defined by KSU Technical Specifications, when:

a. all rods are inserted to the reactor core
b. the reactor is subcritical by at least $1.00 in the reference core condition, but EXCLUDED the reactivity worth of all installed experiments
c. the console key is OFF position and no work is in progress involving core fuel, core structure, installed control rods, or control rod drives
d. the reactor is subcritical by at least $1.00 in the reference core condition with the reactivity worth of all installed experiments INCLUDED QUESTION B.03

[1.0 point, 0.25 each]

Match each of the Technical Specification Limits in column A with its corresponding value in column B. (Each limit has only one answer, values in Column B can be used once, more than once or not at all.)

Column A Column B (limit shall not exceed)

a. Maximum excess reactivity
1. $0.25
b. Maximum individual experiment worth
2. $0.50
c. Minimum Shutdown Margin
3. $2.00
d. Maximum Reactivity Insertion
4. $3.00 in Pulse Mode
5. $4.00
6. $5.00

Section B - Normal/Emergency Procedures and Radiological Controls QUESTION B.04

[1.0 point]

Assume an individual has received whole body occupational exposures of:

1 mrads of gamma 1 mrads of alpha What would be the cumulative dose equivalent (HT) in mrem for this individual?

a. 2 mrem
b. 11 mrem
c. 21 mrem
d. 31 mrem QUESTION B.05

[1.0 point]

Assume that there is no leak from outside of the demineralizer tank. You use a survey instrument with a window probe to measure the dose rate from the demineralizer tank.

Compare to the reading with a window CLOSED, the reading with a window OPEN will :

a. increase, because it can receive an additional alpha radiation from (Al-27) (n,), (Na-24) reaction
b. remain the same, because the Quality Factors for gamma and beta radiation are the same
c. increase, because the Quality Factor for beta and alpha is greater than for gamma
d. remain the same, because the survey instrument would not be detecting beta and alpha radiation from the tank QUESTION B.06

[1.0 point]

Which ONE of the listed radioisotopes produces the highest ionizing energy gamma?

a.

H3

b.

N16

c.

Ar41

d.

U235

Section B - Normal/Emergency Procedures and Radiological Controls QUESTION B.07

[1.0 point]

The radiation from an unshielded source is 1 rem/hr. When you insert 60 mm thickness of lead sheet, the radiation level reduces to 250 mrem/hr. What is the half-value-layer of lead? (HVL:

thickness of lead required so that the original intensity will be reduced by half)?

a. 10 mm
b. 20 mm
c. 30 mm
d. 40 mm QUESTION B.08

[1.0 point]

Which ONE of the following conditions is NOT a violation of a Limiting Condition for Operations?

a. Reactor operator conducted a pulse. The peak power reached 2000 MW
b. Reactor was at full power. The heat exchanger failed, cause the primary coolant temperature exceeding 130 °F
c. During a reactor startup, high voltage to reactor power detector failed the Channel Check
d. Reactor operator could withdraw the SHIM rod in the PULSE Mode QUESTION B.09

[1.0 point]

A radioactive source reads 2 Rem/hr on contact. Five hours later, the same source reads 1.0 Rem/hr. How long is the time for the source to decay from a reading of 2 Rem/hr to 20 mRem/hr?

a. 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />
b. 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />
c. 33 hours3.819444e-4 days <br />0.00917 hours <br />5.456349e-5 weeks <br />1.25565e-5 months <br />
d. 41 hours4.74537e-4 days <br />0.0114 hours <br />6.779101e-5 weeks <br />1.56005e-5 months <br />

Section B - Normal/Emergency Procedures and Radiological Controls QUESTION B.10

[1 point]

Per SOP 27, which ONE of the following is a MINIMUM staffing requirement during the fuel movement?

a. 2 trainees in the reactor bay + 1 RO at console
b. 1 RO at console + 2 trainees in the reactor bay + 1 SRO on call
c. 1 RO at console + 1 SRO and 1 trainee in the reactor bay
d. 1 SRO at console + 1 RO and 1 trainee in the reactor bay QUESTION B.11

[1.0 point]

Which ONE of the following materials shall NOT be irradiated at KSU?

a. Any corrosive material
b. Any short half-life material
c. Any explosive material
d. A moveable experiment with $1.50 worth QUESTION B.12

[1.0 point]

Exposing a 1 mCi check source to the continuous air monitor (CAM) detector to verify whether it is operable is considered to be _________________________.

a. a channel calibration
b. a channel check
c. a channel test
d. a channel validation

Section B - Normal/Emergency Procedures and Radiological Controls QUESTION B.13

[1.0 point]

Which ONE of the following requires the NRC APPROVAL for changes?

a. Revise the Procedure 10 - Fuel Element Inspection b

Change a frequency of the requalification written examination from once per year to twice per year c

Delete one of the procedures listed in the KSU Test and Maintenance Procedures d

Reduce a minimum of the Reactor Safeguards Committee from seven to five members QUESTION B.14

[1.0 point]

You perform a fuel element inspection. In measuring the lateral bend, you find the bend of one fuel element exceeds the original bend by 0.125 inches. For this measurement, you will:

a. continue the fuel inspection because this bend is within TS limit
b. continue the fuel inspection because the Technical Specifications require the elongation measurement only
c. stop the fuel inspection; you immediately report the result to the supervisor because it is considered a damaged fuel element d

stop the fuel inspection, you immediately report the result to the U.S. NRC since it is a reportable occurrence QUESTION B.15

[1.0 point]

Each fuel experiment, except for a standard TRIGA instrumented element, shall be limited such that the total radioactivity inventory of iodine isotopes 131 through 135 is no greater than

a. 1 millicuries
b. 5 millicuries
c. 10 millicuries
d. 50 millicuries

Section B - Normal/Emergency Procedures and Radiological Controls QUESTION B.16

[1.0 point]

Which ONE of the following modifications would be considered a 50.59 and the KSU Reactor Facility must file a request to NRC for change? The facility plans to:

a. Replace an identical NPP-1000
b. Change a control rod worth calibration from stop watch to computer
c. Replace a fission chamber with a compensated ion chamber for the Wide Range Log Channel
d. Measure a control rod drop time with new technique QUESTION B.17

[1.0 point]

A significant loss of water occurs in the reactor pool during a rupture of the pool wall. Per SAR-Chapter 13, which ONE of the following is most likely the greatest concern as a result of this event?

a. Zirconium-Hydrides interact with oxygen in air, releasing explosive hydrogen gas due to TRIGA fuel overheat
b. Cladding rupture, fission products release
c. Groundwater contamination to the surrounding water table
d. Increased personnel exposure due to higher amounts of radiation QUESTION B.18

[1.0 point]

The reactor room shall contain a minimum free volume of 144,000 cubic feet. This is an example of

a. Design Features
b. Surveillance Requirements
c. Limiting Conditions for Operation (LCO)
d. Limiting Safety System Setting (LSSS)

Section B - Normal/Emergency Procedures and Radiological Controls QUESTION B.19

[1.0 point]

You plan to perform a pulse. Per KSU Technical Specifications, The MAXIMUM rod drive positioned for reactivity insertion (upon withdrawal) is _____.

a. $1.5
b. $2.0
c. $3.0
d. $4.0 QUESTION B.20

[1.0 point]

In the event of a suspected fuel leak, which ONE of the following nuclides would most likely be found in a Continuous Air Monitor?

a. Ar-41
b. Kr-85
c. N-16
d. Co-60
                                                            • End of Section B ********************************

Section C: Plant and Rad Monitoring Systems QUESTION C.01

[1.0 point]

Which ONE of the following systems will be received an emergency battery backup power in event of a power loss?

a. Primary coolant pump
b. Secondary coolant pump
c. Telephone systems
d. Fire alarm system QUESTION C.02

[1.0 point]

PA-1000 Preamplifier is a part of:

a. Fuel Temperature Channel
b. NLW-1000 Wide Range Log Channel
c. NMP-1000 Multi Range Linear Channel
d. NPP-1000 Percent Power and Pulsing Channel QUESTION C.03

[1.0 point]

A purpose of the pulse rod interlock is to prevent:

a. inadvertently prompt critical while in the Steady State Mode
b. initiation of a pulse while in a low count rate
c. damage of Transient rod drive system
d. Transient rod stuck after pulsing

Section C: Plant and Rad Monitoring Systems QUESTION C.04

[1.0 point]

After pulsing, you measure a pulse peak power. The peak power information comes from

a. NMP 1000
b. NLW 1000
c. NPP 1000
d. PA 1000 QUESTION C.05

[1.0 point]

Per KSU Technical Specifications, which ONE of the following safety system functions must be operable for both steady-state and pulsing operations?

a. Fuel Temperature Scram
b. Pulse Rod Interlock
c. Reactor Power Level Scram
d. Control Rod (standard) Position Interlock QUESTION C.06

[1.0 point]

The Reg rod is located in ______ of the reactor core.

a. E ring
b. D ring
c. C ring
d. B ring

Section C: Plant and Rad Monitoring Systems QUESTION C.07

[1.0 point]

The source interlock system will prevent rod withdrawal unless source level is above a preset level. Which ONE of the following detectors provides the source interlock information?

a. Fission Chamber
b. Compensated Ion Chamber
c. Uncompensated Ion Chamber
d. Fuel Element Thermocouple QUESTION C.08

[2.0 point, 0.5 each]

Reactor is at 100 kW. Match the input signals listed in column A with the reactor AUTOMATICALLY responses listed in column B. (Items in column B may be used more than once or not at all.)

Column A Column B

a. Loss of NPP-1000 High Voltage
1. Just indication ONLY
b. Exhaust fan turned OFF by operator
2. Alarm ONLY
c. Pool water conductivity = 0.5 µmho/cm
3. Interlock
d. Perform a pulse
4. Scram

Section C: Plant and Rad Monitoring Systems QUESTION C.09

[1.0 point]

Attached is the gas-filled detector curve (detector effect vs. voltage). Different regions of this curve are useful for different detectors. Which ONE of the following is the Geiger Mueller region?

a. Region II
b. Region III
c. Region IV
d. Region V

Section C: Plant and Rad Monitoring Systems QUESTION C.10

[1.0 point]

The MAIN purpose of the dashpot installed at the bottom of the barrel is to:

a. prevent structure damage to the barrel
b. reduce bottoming impact during a scram
c. increase the rod scram time for the rod drop test
d. Increase the rod speed during an initial withdrawal

Section C: Plant and Rad Monitoring Systems QUESTION C.11

[1.0 point]

Using the diagram of an instrumented fuel element, select the appropriate materials associated with its locator.

Column A Column B I

A. Zirconium Hydride-Uranium II B. Stainless steel III C. Erbium Burnable Poison IV D. Graphite Reflector E. Zirconium Rod F. Spacer G. Thermocouples

a. I.A, II.E, III.C, IV.G
b. I.D, II.G, III.A, IV.F
c. I.D, II.E, III.A, IV.G
d. I.C, II.A, III.B, IV.G

Section C: Plant and Rad Monitoring Systems QUESTION C.12

[1.0 point]

The Annual Power Level Calibration for NPP-1000 is performed at 100 KW/ hour and the initial temperature of 20 °C. After 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> run, the temperature reaches 26 °C. After obtaining the calibration data, which ONE of the following is a correct method for power adjustment? You should:

Given pool constant = 0.0526 °C per kWh

a. raise the Uncompensated Ion Chamber position to obtain the true power
b. lower the Uncompensated Ion Chamber position to obtain the true power
c. adjust the gain of NPP-1000 Channel to obtain the true power
d. No adjustment of detector is required because the actual power and indicated power are within the range QUESTION C.13

[1.0 point]

The MAIN purpose for placing a Geiger-Mueller detector near the demineralizer and cartridge filter is to detect a present of _____ in the primary water.

a. N-16
b. A-41
c. Tritium
d. fission products QUESTION C.14

[1.0 point]

The MAIN purpose to measure the pressure drop across the filter of the water clean up system is to determine whether:

a. the filter is clogging
b. the demineralizer is clogging
c. the primary pump motor is overheated
d. the heat exchanger is clogging

Section C: Plant and Rad Monitoring Systems QUESTION C.15

[1.0 point, 1/3 each]

Use the following diagram of the control rod. Match the three limit switches listed in Column A to the appropriate labels in Column B?

Column A Column B

a. Magnet Down 1
b. Rod Down 2
c. Magnet Up 3

Section C: Plant and Rad Monitoring Systems QUESTION C.16

[1.0 point]

Which ONE of the following is NOT a basic function of the secondary automatic control system?

a. Maintain the primary water at a set temperature
b. Control the cooling tower fan speed to maintain secondary water temperature within a set range
c. Prevent cooling water freeze-up during cold weather operations
d. Control the primary pressure during reactor operations QUESTION C.17

[1.0 point]

Which ONE of following experimental facilities provides the HIGHEST fast flux?

a. Central Thimble
b. Pneumatic Transfer System
c. Piercing Beam Port next to core
d. Rotary Specimen Rack QUESTION C.18

[1.0 point]

Air to the piston of the Transient rod mechanism is controlled by a _________ solenoid valve mounted below the support structure.

a. one-way
b. two-way
c. three-way
d. four-way

Section C: Plant and Rad Monitoring Systems QUESTION C.19

[1.0 point]

Attached is the KSU Cooling System Layout. Which ONE of the following labels is indicated a location of the N-16 diffuser?

a. Label A
b. Label B
c. Label C
d. Label D
                                      • End of Section C ****************************
                                      • End of the Exam ***************************

Section A Theory, Thermo & Facility Operating Characteristics A.01 Answer d

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 4.6, page 4-

17.

A.02 Answer:

c

Reference:

Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 4.2 A.03 Answer:

b

Reference:

P = P0 et/T = 10 kW e(60sec/-80sec) = 10 kW

  • e-0.75 = 0.472 10 kW = 4.7 kW A.04 Answer:

b

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 3.2.1, page 3-

5.

A.05 Answer:

d

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 3.3.3, page 3-21.

reactor A = (Keff1-Keff2)/(Keff1*Keff2). (0.2-0.1)/(0.2*0.1) = 5 k/k reactor B = (Keff1-Keff2)/(Keff1*Keff2). (0.9-0.8)/(0.9*0.8) = 0.139 k/k 5/0.139 = 36 A.06 Answer:

c

Reference:

Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3 A.07 Answer:

d

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Page 4-21.

A.08 Answer d

Reference:

DOE Fundamentals Handbook Nuclear Physics and Reactor Theory Vol. 2 A.09 Answer:

b

Reference:

Nuclides and Isotopes N = A - Z 3-1 = 2

Section A Theory, Thermo & Facility Operating Characteristics A.10 Answer:

d

=($)*; 1=$1.20*0.007= 0.0084 k/k 2=$2.0*0.007= 0.014 k/k Peak2 = Peak1*(0.014-.007/.0084-.007)2 = 5000 MW Or Peak2 = Peak1*($2-$1 / $1.2-$1)2 = 5000 MW A.11 Answer:

c

Reference:

Time is related to ratio of final power to initial power. 2:1 is the largest ratio.

A.12 Answer:

c

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 3.2.

A.13 Answer:

d

Reference:

Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Figure 2.6, page 2-39 A.14 Answer:

c

Reference:

from k=0.955 to criticality (k=1), D = (k-1)/k = -0.047 Dk/k or D = 0.047 Dk/k needed to reach criticality. From criticality to JUST prompt, Dk/k = eff required, so minimum reactivity added to produce prompt criticality will be: 0.047+0.007= 0.054 A.15 Answer:

b a

per facility comment

Reference:

CR = S/(1-K) CR = 300/(1 -.7) = 1000 S = S0 M = 210 neutrons / sec A.16 Answer:

a

Reference:

Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 2.4.5 A.17 Answer c

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 8.1 A.18 Answer:

a

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, ©4.5, 1988 Peak

)

(

=

Peak

)

(

1 1

2 2

2 2

Section A Theory, Thermo & Facility Operating Characteristics A.19 Answer:

d

Reference:

TRIGA Fuel Design A.20 Answer:

c

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 3.3.1, page 3-16.

Section B Normal, Emergency and Radiological Control Procedures B.01 Answer:

d

Reference:

EP 4.4 and 8.2 B.02 Answer:

d

Reference:

TS 1.0 B.03 Answer:

a(5) b(3) c(2) d(4)

Reference:

TS 3.1, 3.2, and 3.6 B.04 Answer: c

Reference:

10 CFR 20 B.05 Answer:

d

Reference:

BASIC Radiological Concept (Betas and alpha don't make through the demineralizer tank)

B.06 Answer:

b

Reference:

Chart of the Nuclides B.07 Answer:

c

Reference:

DR = DR*e -X Find : 250 = 1000* e -*60 ; = 0.0231 If insertion of an HVL (thickness of lead), the original intensity will be reduced by half.

Find X: 1 = 2* e -0.0231*X ; X= 30 mm Find HVL by shortcut:

1000mR-500 mR is the 1st HVL 500 mR - 250 mR is the 2nd HVL So HVL=60mm/2 = 30 mm B.08 Answer:

a

Reference:

TS 3.3, 3.4, and 3.8

Section B Normal, Emergency and Radiological Control Procedures B.09 Answer:

c

Reference:

DR = DR*e -t 1 rem/hr =2 rem/hr* e -(5hr)

Ln(1.0/2) = -*5 --> =0.1386; solve for t: Ln(.02/2)=-0.1386 (t) t=33 hours B.10 Answer:

c

Reference:

SOP 27 B.11 Answer:

d

Reference:

TS 5.4 B.12 Answer:

c

Reference:

TS 1.0 B.13 Answer:

d

Reference:

TS 6.2 (TS changes required an amendment)

B.14 Answer:

c a per facility comment

Reference:

TS 3.7 B.15 Answer:

b

Reference:

TS 5.4 B.16 Answer:

c

Reference:

10 CFR 50.59 B.17 Answer:

d

Reference:

SAR 13.1 B.18 Answer:

a

Reference:

TS 5.3 B.19 Answer:

c

Reference:

TS 3.2 B.20 Answer:

b

Reference:

NRC standard question for TRIGA design

Section C Facility and Radiation Monitoring Systems C.01 Answer:

d

Reference:

SAR, Chapter 8.2 C.02 Answer:

b

Reference:

SAR, Chapter 7.3 C.03 Answer:

a

Reference:

TS 3.4 C.04 Answer:

c

Reference:

Training Manual, Chapter 7 C.05 Answer:

a

Reference:

TS 3.3 and 3.4 C.06 Answer:

a

Reference:

SAR C.07 Answer:

a

Reference:

Training Manual, Figure 8 C.08 Answer:

a(4) b(1) c(1) d(3)

Reference:

SAR Chapter 7 and TS 3.5 C.09 Answer:

d

Reference:

Bevelacqua, J. Basic Health Physics C.10 Answer:

b

Reference:

NRC Standard Question

Section C Facility and Radiation Monitoring Systems C.11 Answer:

c

Reference:

Triga Fuel Element C.12 Answer:

a b

per facility comment

Reference:

Delta T at true 100 kWh =0.0526 °C per kWh *100 kW =5.26 °C at 100 kWh True power = (6 °C/5.26 °C)*100 kW =114 kW, so you need to raise lower the detector to obtain the true power at 114 kW C.13 Answer:

d

Reference:

Training Manual, Reactor Cooling System C.14 Answer:

a

Reference:

Training Manual, Reactor Cooling System C.15 Answer:

a(1) b(3) c(2)

Reference:

Training Manual, Figure 9 C.16 Answer:

d

Reference:

Training Manual, Reactor Cooling System C.17 Answer:

a

Reference:

Training Manual 5.7 C.18 Answer:

c

Reference:

Training Manual, Transient Rod Drive Mechanism C.19 Answer:

b

Reference:

SAR Figure 5.1