10 CFR 50.55a 0aps Palo Verde Nuclear Generating Station P.O. Box 52034 Phoenix, AZ 85072 Mail Station 7636 Tel: (623) 393-5764 102-06903-TNW/CJS June 27, 2014 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Dear Sirs:
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Unit 2, Docket No. STN 50-529 Third 10-Year Interval, Third Period:
Owner's Activity Report Number U2R18 Pursuant to 10 CFR 50.55a and in accordance with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Case N-532-4, Arizona Public Service Company (APS) hereby submits the Owner's Activity Report (Form OAR-i) for Unit 2 refueling outage 18 (U2R18). The outage ended on May 5, 2014.
No commitments are being made to the NRC by this letter. Should you need further information regarding this submittal, please contact me at (623) 393-5764.
Sincerely, Thomas N. Weber Department Leader, Regulatory Affairs TNW/CJS/hsc
Enclosure:
Unit 2 Eighteenth Refueling Outage Owner's Activity Report, Report U2R18 cc:
M. L. Dapas J. K. Rankin M. M. Watford M. A. Brown NRC Region IV Regional Administrator NRC NRR Project Manager (electronic and hard copy)
NRC NRR Project Manager (electronic and hard copy)
NRC Senior Resident Inspector for PVNGS (electronic)
A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway 0 Comanche Peak
- Diablo Canyon 0 Palo Verde 0 Wolf Creek A~Lr1
ENCLOSURE Unit 2 Eighteenth Refueling Outage Report Owner's Activity Report U2R18
FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number: 2R18 Plant: Palo Verde Nuclear Generating Station, 5801 S. Wintersburg Road, Tonopah, Arizona 85354-7529 Unit No.: 2 Commercial service date:
Sep 19, 1986 Refueling Outage No.: 18 (if applicable)
Current inspection interval IWB, IWC, IWD, IWF = 3rd, IWE, IWL = 2nd (1', 2', 3', 40, other)
Current inspection period IWB,IWC, IWO, IWF, IWE =3rd IWL = 2nd (11, 2m, 3")
Edition and Addenda of Section XI applicable to the inspection plans 2001 ed, 2003 ad, IWL 2007 ed 2008 ad Date and revision of inspection plans ISI = 8/28/13 R4, Press Test = 3/19/14 R4, IWE = 3/24/09 R0, IWL = 11/8/12 R1 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans 2001 ed 2003 ad Code Cases used: N-532-4 (if applicable)
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of U2R18 conform to the requirements of Section XI.
(refueling outage number)
Lehnman, Villiam Digitally signed by Lehman, William T(Z60076)
DN: cn=Lehman, William T(Z60076)
Signed T(Z60076)Date: 2014.06.11 08:40:06 -07'00' Date:
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Arizona and employed by HSB GS of Hartford, Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Digitally signed by Hogstrom,
- Hogstrom, Robert (YH2450)
DN: cn=Hogstrom, Robert Robert (YH2450) (YH245o)
Date: 2014.06.12 08:22:46 -07'00' Commissions N.B. 9685, Az 264, "IS, A, I, N, C" (Inspectors Signature)
National Board, State, Province, and Endorsements Date:
Jun 12, 2014 PV-E0796 Ver. 1
Palo Verde Nuclear Generating Station Owners Activity Report - Unit 2 Refueling Outage 18 Table 1 Items with flaws or relevant conditions that required evaluation for continued service Examination Item Description Evaluation Category Number of Work Description None None None None 2
Palo Verde Nuclear Generating Station Owners Activity Report - Unit 2_ Refueling Outage 18 Table 2 Abstract of repair/replacement activities required for continued service Item Description Date Repair/Replacement Code Class Description of Work Completed Plan Number 1
2MRCEE01A Hot leg tube plugging SG 1 04/28/14 4422035 1
2MRCEE01A Cold leg tube plugging SG1 04/28/14 4422036 1
2MRCEE01 B Hot leg tube plugging SG 2 04/28/14 4422037 1
2MRCEE01 B Cold leg tube plugging SG2 04/28/14 4422038 2
2PSGEL002 replaced piping for FAC 05/01/14 4335568 2
2PSGEL008 replaced piping for FAC 05/01/14 4479590 3
2MDGBE01B intercooler weld repair and stud replacement 03/31114 4021392 3
2MDGBE01A intercooler weld repair and stud replacement 03/31/14 4021245 3
2MDGBH01 DG JW piping to stand pipe weld repair 03131/14 4236310 3
2MDGBE05 JW cooler weld repair 03/31/14 4305288 3
2MDGBE04 LO cooler weld repair 03/31/14 4305330 4