Trapp, James From:

Hardies, Robert Sent:

Thursday, October 04, 2012 8:34 AM To:

Gray, Harold Cc:

Screnci, Diane; Sheehan, Nell; Trapp, James; Burns, Thomas; Wilson, Peter; Miller, Chris

Subject:

RE: Newspaper opinion article RE reactor vessel cracks Thanks for this Harold.

We are going to have a public meeting after we all get back from another round of meetings with the Belgian regulator during the week of October 15.

The public meeting is not set up yet, so I don't have a date.

Vermont Yankee doesn't have any Rotterdam forgings, and no forgings at all for the shell courses.

They were all welded plate construction.

The flanges are forgings, but the flanges have bolt holes and sealing surfaces and weld preps that were examined with surface techniques that would have picked up large numbers (or even small numbers) of linear indications.

So it is safe to say that the indications found at Doel 3 cannot exist at Vermont Yankee.

La._

(b)(5)

Robert Hardies Senior Level Advisor for Materials Engineering Division of Engineering Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission r

ffice Phone 301 415-5802 Cell ZIIb)Z Original Message -----

From: Gray, Harold Sent: Thursday, October 04, 2e12 7:49 AM To: Hardies, Robert Cc: Screnci, Diane; Sheehan, Neil; Trapp, James; Burns, Thomas; Wilson, Peter; Miller, Chris

Subject:

FW: Newspaper opinion article RE reactor vessel cracks

Bob, in case you do not already have it, the attached.

Is NRC going to issue a summary on the significance to US plants of these UT indications, which have been characterized as hydrogen flaking, small indications In the plane of the shell surface, similar to laminations?

As I read the related info, it looks like the vacuum degassing or post forming heat treatment of the shell ring forging by the steel producer were factors in the indication development.

Harold Gray Original Message -----

From: Rutenkroger, Scott Sent: Thursday, October 94, 2912 7:25 AM To: Gray, Harold; Burns, Thomas

Subject:

FW: Newspaper opinion article RE reactor vessel cracks 1

Either of you know anything? Or, are the current ISI and NDE inspections such that we already know it isn't possible?

Thanks, Scott Original Message -----

From: Rutenkroger, Scott Sent: Thursday, October 04, 2012 7:20 AM To: Bellamy, Ronald; Setzer, Thomas; Keighley, Elizabeth; DeBoer, Joseph; Guzman, Richard

Subject:

Newspaper opinion article RE reactor vessel cracks I read this article in a local newspaper last night. I'm evaluating it for potential to be an allegation.

I would think this would be an issue for which the validity is known, making it NOT an allegation. However, I don't recall any such discussion or Information.

Anyone know anything?