Duke REGIS T. REPKO Duke r ~
Vice President Energy.
McGuire Nuclear Station Duke Energy MGO IVP / 12700 Hagers Ferry Rd.
Huntersville, NC 28078 980-875-4111 980-875-4809 fax regis. repko@duke-energy. com June 28, 2011 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555
Subject:
Duke Energy Carolinas, LLC (Duke)
McGuire Nuclear Station Docket Number 50-370 Inservice Inspection Report Unit 2, End of Cycle 20 Refueling Outage In accordance with ASME Section XI, attached is the Inservice Inspection Report for the end of cycle 20 (EOC-20) refueling outage for McGuire Nuclear Station, Unit 2. This was the third outage of the Second Inspection Period of the Third Ten-Year Interval.
No reportable indications were identified during this report period. Section 4.4 of the report lists one limited examination item number.
Questions regarding this submittal should be directed to Kay L. Crane at (980) 875-4306.
Regis T. Repko Attachment www.duke-energy.conm Q
i t2
U. S. Nuclear Regulatory Commission June 28, 2011 Page 2 xc V. M. McCree Regional Administrator, Region II U.S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, GA 30303-1257 Senior Resident Inspector U.S. Nuclear Regulatory Commission McGuire Nuclear Station J.H. Thompson. (addressee only)
NRC Project Manager U.S. Nuclear Regulatory Commission 11555 Rockville Pike Mail Stop 0-8 G9A Rockville MD 20852-2738
INSERVICE INSPECTION REPORT Duke Energy Carolinas McGuire Nuclear Station Unit 2 Twentieth Refueling Outage Energy 8
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1.
Owner: Duke Enerav Carolinas. 526 S. Church St.. Charlotte. NC 28201-1006 (Name and Address of Owner)
- 2.
Plant: McGuire Nuclear Station. 12700 Haqer's Ferry Road Huntersville, N.C. 28078 (Name and Address of Plant)
- 3.
Plant Unit:
2
- 4. Owner Certificate of Authorization (if required) N/A
- 5.
Commercial Service Date: March 1, 1984 6. National Board Number for Unit 84
- 7.
Components Inspected:
Comnp on ent or A ppu rten an ce Manufacturer or M an ufactu rer or Installer Installer Serial N o.
State or Province No.
National Board N o.
See Section 1.1 in the Attached Report Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
Total number of pages contained in this report 188
(
- 9.
Examination Dates October 11, 2009 to April 5, 2011
- 9.
Inspection Period Identification:
- 10.
Inspection Interval Identification:
- 11.
Applicable Edition of Section XI
- 12.
Date / Revision of Inspection Plan:
Second Period Third Interval 1998 Addenda 2000 June 20, 2006 / Revision 2
- 13.
Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.
See Sections 2.0, 3.0 and 6.0
- 14.
Abstract of Results of Examinations and Tests.
- 15.
Abstract of Corrective Measures.
See Section 4.0 and 6.0 See Subsection 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.
Certificate of Authorization No. (if applicable)
N/A Expiration Date N/A Date
,. I 3 = 7-7 Z o, Signed Duke Energy Carolina's.
Owner By IMA9,- A.-
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina employed by
- HSBCT have inspected the components described in this Owner's Report during the period October 11, 2009 to April 5, 2011 and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor
- s employer shall be liable in any manner for any personal injury or property damage rloss of anýy k rng from or connected with this inspection assions N.C. 1524,-I NdA?
1Z // 7--
Instor nature National Board, State, Province, and Endorsements
/
A -ntur Date (0
/
0('0 1 / -
HSBCT 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbct.com
OWNER'S REPORT FOR INSERVICE INSPECTIONS MCGUIRE UNIT 2 2011 REFUELING OUTAGE EOC 20 (OUTAGE 5)
(Third Interval)
Plant Location:
McGuire Nuclear Station 12700 Hager's Ferry Road Huntersville, North Carolina 28078 - 9340 NRC Docket No. 50-370 National Board No. 84 Commercial Service Date: March 1, 1984 Document Completion Date: *-6.'7, 20t(
Owner: Duke Energy Carolinas 526 South Church Street Charlotte, N.C. 28201-1006 Revision 0 Originated By:
Checked By:
Approved By:
ODate aDate 0'7-
/3 -o/
Date
TABLE OF CONTENTS Section Title Revision 1.0 General Information 0
2.0 Third Ten-Year Interval Inspection Status 0
3.0 Final Inservice Inspection Plan 0
4.0 Results of Inspections Performed 0
5.0 Owner's Report for Repair / Replacement Activities 0
6.0 Pressure Testing 0
1.0 General Information This report describes the Inservice Inspection of Duke Energy Corporation's McGuire Nuclear Station Unit 2 during Outage 5 / EOC 20. This is the third outage of the Second Inspection Period of the Third Ten-Year Interval. ASME Section XI, 1998 Edition with the 2000 Addenda, was the governing Code for selection and performance of the ISI examinations.
Included in this report are the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective action(s) taken when reportable conditions were found. In addition, there is an Owner's Report for the Repair / Replacement Section included for completed NIS-2 documentation of repairs and replacements.
1.1 Identification Numbers Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No.
Province No.
No.
Reactor Vessel Rotterdam 30664 NC-201819 Pressurizer Westinghouse 1491 NC-201818 W10285 Steam Generator 2A BWI 7700-02 NC-302674 159 Steam Generator 2B BWI 7700-04 NC-302675 161 Steam Generator 2C BWI 7700-01 NC-302676 158 Steam Generator 2D BWI 7700-03 NC-302677 160 Centrifugal Charging Pump Pacific Pumps 2A - 48584 N/A 25 2B-48585 28 Containment Spray Heat Delta Southern Co.
2A-35005-73-3 NC-234203 3396 Exchanger Joseph Oat &
(2B) 2514 NC-201822 5765 Sons, Inc.
Excess Letdown Heat Westinghouse 1810 NC-234264 1555 Exchanger Letdown Heat Exchanger Joseph Oat &
2049-2B NC-201842 553 Sons, Inc.
Reciprocating Charging Union Pump Co.
N7210318-604 N/A N/A Pump EOC 20 Refueling Outage Report McGuire Unit 2 Section 1 Page 1 of 5 Revision 0 June 7, 2011
1.1 Identification Numbers (Continued)
Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No.
Province No.
No.
2A 5-114E841G02 Reactor Coolant Pump Westinghouse 2B 6-114E841G02 N/A N/A 2C 7-114E841G02 2D 8-114E841G02 Reciprocating Charging Metal Bellows Company 74730-002 N/A 002 Pump Accumulator Reciprocating Charging Richmond Engineering N-2409.20 N/A 75220 Pump Suction Stabilizer Supply Co.
Residual Heat Joseph Oat & Sons, Inc.
2A 2046-2C NC-169800 637 Removal Heat 2B 2046-2D NC-201823 638 Exchanger Safety Injection Pump Pacific Pumps 2A 49357 N/A 130 2B 49358 131 Regenerative Heat Joseph Oat & Sons, Inc.
2047-2B NC-201817 628 Exchanger 629 630 Seal Water Heat Atlas Industrial 1767 NC 201827 1549 Exchanger Manufacturing Company Seal Water AMF Cuno 2A - 20 N/A 4364 Injection Filter 2B - 22 4365 Main Steam Supply to Duke Power Co.
SA N/A 62 Auxiliary Equipment System Containment Air Release Duke Power Co.
VQ N/A 56 and Addition System Main Steam System Duke Power Co.
SM N/A 70 Main Steam Vent to Duke Power Co.
SV N/A 67 Atmosphere System Reactor Coolant System Duke Power Co.
NC N/A 82 EOC 20 Refueling Outage Report McGuire Unit 2 Section 1 Page 2 of 5 Revision 0 June 7, 2011
1.1 Identification Numbers (Continued)
Manufacturer Manufacturer or Installer State or National Item or Installer Serial No.
Province No.
Board No.
Liquid Waste Recycle Duke Power Co.
WL N/A 76 System Refueling Water System Duke Power Co.
FW N/A 54 Auxiliary Feedwater Duke Power Co.
CA N/A 73 System Residual Heat Removal Duke Power Co.
ND N/A 63 System Nuclear Service Water Duke Power Co.
RN N/A 60 System Chemical & Volume Duke Power Co.
NV N/A 80 Control System Component Cooling Duke Power Co.
KC N/A 78 System Main Feedwater System Duke Power Co.
CF N/A 61 Containment Spray Duke Power Co.
NS N/A 69 System Containment Ventilation Duke Power Co.
RV N/A 72 Cooling Water System Safety Injection System Duke Power Co.
NI N/A 83 Diesel Generator Engine Duke Power Co.
KD N/A 47 Cooling Water System Spent Fuel Cooling Duke Power Co.
KF N/A 81 System Diesel Generator Engine Duke Power Co.
LD N/A 51 Lube Oil System Unit 2 Duke Power Co.
N/A N/A 84 EOC 20 Refueling Outage Report McGuire Unit 2 Section 1 Page 3 of 5 Revision 0 June 7, 2011
1.2 Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke Energy Carolina's Corporate Office in Charlotte, North Carolina:
- 1.
Code Case N-460 (Alternative Examination Coverage for Class 1 and Class 2 Welds, Section Xl, Division 1.) Applicable to items in this report where less than 100% coverage of the required weld examination volume was achieved.
- 2.
Code Case N-665 (Alternative Requirements for Beam Angle Measurements using Refracted Longitudinal Wave Search Units.)
- 3.
Code Case N-700 (Alternative Rules for Selection of Classes 1, 2 and 3 Vessel Welded Attachments for Examination Section Xl, Division 1) (Categories B-K, CC and D-A)
- 4.
Code Case N-706 (Applicable to Category C-A Residual Heat Removal Heat Exchangers 2A and 2B and the Regenerative Heat Exchanger.)
- 5.
Problem Investigation Process (PIP) M-1 1-04257 (Covers documentation and tracking and completion of request for relief on weld limitations for EOC 20.) See Section 4.4 for list of limited exams.
- 6.
RFR 03-002 (Class 1, 2 and 3 snubber examination under station technical specification SLC 16.9.15.)
- 7.
RFR 01-005 (Risk Informed Inservice Inspection Program Submittal.)
- 8.
RFR 01-008 (Risk Informed ISI Alternative to Use VT-2 Instead of Volumetric Examination of Socket Welds.)
- 9.
Code Case N-722 (Additional Examinations for Pressure Retaining Welds in Class 1 Components Fabricated with Alloy 600 / 82 / 182 Materials, Section Xl, Division 1, 10 CFR Part 50, Federal Register, final rule was issued September 10, 2008 mandates the use of this code case.) (Effective date is October 10, 2008.)
- 10.
Code Case N-685 (Lighting Requirements for Surface Examinations, Section Xl, Division 1.)
- 11.
Code Case N-729-1 (Alternative Examination Requirements for PWR Reactor Vessel Upper Heads with Nozzles Having Pressure Retaining Partial Penetration Welds Section Xl, Division 1. 10CFR Part 50, Federal Register, final rule was issued September 10, 2008 mandates the use of this code case.)
- 12.
Plan Addenda 2MNS-065 (changed Category B-D B3.100 inspections req. from 36 to 40) and 2MNS-066 (changed Category RA inspections req. from 91 to 137.)
- 13.
PIP G-1 0-0134 This PIP was written to address changes to Category B-D B3.100's.
EOC 20 Refueling Outage Report Page 4 of 5 McGuire Unit 2 Revision 0 Section 1 June 7, 2011
- 14.
PIP M-1 1-1233 This PIP was written to address snubber being locked up.
Engineer evaluation determined snubber was not locked up documented in PIP.
- 15.
PIP G-10-3538 This PIP was written to address changes to Category RA.
- 16.
PIP M-1 1-1508 This PIP was written for Summary Number M2.G6.2.0001 to address accumulation of boron on PZR manway cover, Engineer evaluation determined powder to be insulation dust.
- 17.
PIP M-1 1-1846 This PIP was written to address adjacent weld 2NV2FW183-28 with linear indication outside of Section XI exam boundaries.
EOC 20 Refueling Outage Report McGuire Unit 2 Section 1 Page 5 of 5 Revision 0 June 7, 2011
2.0 Third Ten-Year Interval Inspection Status The completion status of inspections required by the 1998 ASME Code Section Xl through the 2000 Addenda is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections and IWF-2500-1 for Class 1, 2 and 3 Component Supports. Augmented, Elective, and Risk Informed Inspections are also included.
During the McGuire Third 10 Year Interval, piping welds will be examined under the Risk Informed Inservice Inspection Program developed in accordance with methodology contained in the Westinghouse Owner's Group (WOG) Topical Report, WCAP-14572, Revision 1-NP-A and its Supplement 2 Revision 1-NP-A. Request for Relief 01-005 was submitted to the NRC seeking approval to incorporate the Risk Informed Program into the Third 10 Year Interval ISI Plan for McGuire Unit 2. The NRC approved use of this program per SER dated June 12, 2002. Previous code examination Categories B-F, B-J, C-F-i, and C-F-2 will now be combined under the new Risk Informed Category R-A.
Class 1 Inspections Examination Description Inspections Inspections Percentage (1)Deferral Category Required Completed Completed Allowed B-A Pressure Retaining Welds 15 3
20.00%
Yes in Reactor Vessel B-B Pressure Retaining Welds 5
3 60.00%
No in Vessels Other than Reactor Vessel B-D Full Penetration Welded 40 20 50%
Partial Nozzles in Vessels (4)
Inspection Program B Reference B-F Pressure Retaining Risk N/A N/A (2)
Dissimilar Metal Welds in Informed Vessel Nozzles Program R1. Items B-G-1 Pressure Retaining Bolting 241 175 72.61%
Yes Greater than 2" in Diameter B-G-2 Pressure Retaining Bolting 22 15 68.18%
No 2" and Less in Diameter I
EOC 20 Refueling Outage Report McGuire Unit 2 Section 2 Page I of 5 Revision 0 June 7, 2011
Class I Inspections (Continued)
Examination Description Inspections Inspections Percentage 1Deferral Category Required Completed Completed Allowed Reference B-J Pressure Retaining Risk Informed N/A N/A (2)
Welds in Piping Program RI.
Items B-K Welded Attachments for 5
4 80%
No Vessels, Piping, Pumps (3)
(3) and Valves B-L-1 Pressure Retaining N/A N/A N/A Yes Welds in Pump Casings B-L-2 Pump Casings 1
0 00.00%
Yes B-M-1 Pressure Retaining N/A N/A N/A Yes Welds in Valve Bodies B-M-2 Valve Body > 4 in.
9 4
44.44%
Yes Nominal Pipe Size B-N-1 Interior of Reactor 3
2 66.66%
No Vessel B-N-2 Welded Core Support 2
0 00.00%
Yes Structures and Interior Attachments to Reactor Vessel B-N-3 Removable Core 1
0 00.00%
Yes Support Structures B-O Pressure Retaining 3
2 66.66%
Yes Welds in Control Rod Housings B-P All Pressure Retaining REFERENCE SECTION 6.0 OF THIS REPORT Components B-Q Steam Generator (5)
Tubing F-A Class 1 Component 58 36 62.10%
No F1.10.
Supports EOC 20 Refueling Outage Report McGuire Unit 2 Section 2 Page 2 of 5 Revision 0 June 7, 2011
Class 2 Inspections Examination Description Inspections Inspections Percentage Category Required Completed Completed C-A Pressure Retaining Welds 30 12.5 42%
in Pressure Vessels (6)
(6)
C-B Pressure Retaining Nozzle 11 7
63.63%
Welds in Vessels C-C Welded Attachments for 17 12 70.60%
Vessels, Piping, Pumps and Valves C-D Pressure Retaining Bolting N/A N/A N/A Greater Than 2" in Diameter Reference C-F-1 Pressure Retaining Welds Risk Informed (2)
(2) in Austenitic Stainless Program RI.
Steel or High Alloy Piping Items Reference C-F-2 Pressure Retaining Welds Risk Informed (2)
(2) in Carbon or Low Alloy Program RI.
Steel Piping Items C-G Pressure Retaining Welds 8
4 50%
in Pumps and Valves C-H All Pressure Retaining REFERENCE SECTION 6.0 OF THIS Components REPORT F-A Class 2 Component 230 148 64.30%
F1.20.
Supports Additional Component Support Examinations Class 1, 2 and 3 Examination Description Inspections Inspections Percentage Category Required Completed Completed F-A Supports other than Piping 42 30 71.40%
F1.40.
Supports Class 1, 2 & 3 F-A Component Supports (7)
F1.50.
Snubbers Class 1, 2 & 3 EOC 20 Refueling Outage Report McGuire Unit 2 Section 2 Page 3 of 5 Revision 0 June 7, 2011
Risk Informed Inservice Inspection Program Class I and 2 Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed (2)R-A Piping Examinations Class 137 71 51.80%
No 1 and 2 (8)
Weld Overlay Section XI Appendix Q Augmented / Elective Inspections Summary Description Percentage Complete Number G1.1 Reactor Coolant Pump Flywheels No examinations required for Outage 5/ EOC 20 G2.1 RPV Closure Head Studs and Nuts per No examinations required for Outage 5 I EOC 20 Nuclear Guide 1.65 G3.1 Pipe Rupture Protection No examinations required for Outage 5 / EOC 20 G5.1 RPV Head Penetration Nozzles No examinations required for Outage 5/ EOC 20 G5.2 RPV Vent Line No examinations required for Outage 5 I EOC 20 G6.2 Pressurizer Manway 100% of Outage 5 / EOC 20 Requirements Met B15.80 Reactor Vessel BMI Nozzles 100% of Outage 5 / EOC 20 Requirements Met B4.10 Reactor Vessel Head 100% of Outage 5 / EOC 20 Requirements Met B4.20 Reactor Vessel Head Pen and Reactor No examinations required for Outage 5 / EOC 20 Vessel Head Vent EOC 20 Refueling Outage Report McGuire Unit 2 Section 2 Page 4 of 5 Revision 0 June 7, 2011
NOTES:
(1) Deferral of inspection to the end of the interval as allowed by ASME Section XI Table IWB 2500-1. These examination categories are exempt from percentage requirements per IWB-2412 (a), Inspection Program B.
(2) RFR 01-005 (3) Beginning with EOC-19, Code Case N-700 has been incorporated for Category B-K. This reduced the required number of exams to five from six. The impact on percentages for this category is only due to implementation of the code case during the interval.
(4) Totals changed from 36 to 40 due to Plan Addendum 2MNS-065 adding (4) B3.100's reference PIP G-10-0134.
(5) Steam Generator Tubing is examined and documented by the Steam Generator Maintenance and Engineering Group as required by the Station Technical Specifications and is not included in this report.
(6) Beginning with EOC-19, Code Case N-706 has been incorporated for Category C-A. This code case covers the examinations associated with the Regenerative and Residual Heat Removal Heat Exchangers.
(7) Inspections to be performed per Relief Request 03-002 (8) Totals changed from 91 to 137 per Plan Addendum 2MNS-066, reference PIP M-10-3538.
EOC 20 Refueling Outage Report McGuire Unit 2 Section 2 Page 5 of 5 Revision 0 June 7, 2011
3.0 Final Inservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section Xl Class 1, Class 2, Class 3, Augmented and Risk Informed examinations credited for this report period.
EOC 20 Refueling Outage Report McGuire Unit 2 Section 3 Page 1 of 1 Revision 0 June 7, 2011
ScheduleWorks DUKE ENERGY NUCLEAR TECHNICAL SERVICES Inservice Inspection Database Management System Plan Report McGuire 2, 3rd Interval, Outage 5 (EOC-20)
This report includes all changes through addendum 2MNS-074 Summary Nui Category AUG M2.B15.80.0001 m
Component ID ISO/DWG Numbers Class I System 2-RPV-BMI-NOZZLES Class 1 NC MP\\0\\A\\7150-165 Procedure Insp Req Material Sched Description Comments Thick/NPS Cal Blocks Componenet ID 2 NDE-69 VT-2 Inconel Transition Weld to Stainless Steel Tube Bare Metal Visual Inspection by VT-2 qualified inspector of the BMI Nozzles per the requiements of Code Case N-722 (Item B15.80). The bare metal visual inspection shall include an inspection of the bottom head and Alloy 600 transition weld between the Alloy 600 tube and the stainless steel tube. This exam added per QA-513J ER-MNS-09-01. This exam should be scheduled every other outage begining with EOC-1 9. Reference Footnote 4 of Code Case N-722 for type of examination. Any questions concerning this exam should be directed to the Materials and NDE Services Group (Chris Cruz or Jody Suping).
These augmented examinations are being added to the ISI Plan per QA-513-J Form, Tracking Number ER-MNS-10-03, initiated by C.A. Cruz of the Materials and NDE Services Group. All bottom mounted instrument (BMI) nozzles and transition welds will be examined every refueling outage instead of every other outage outlined in ER-MNS-09-01.
M2.134.10.0001 2RPV-Head Class 1 NC MCFD 2553-01.00 MCM 2201.01-0021 001 NDE-70 VT-2 As specified in ASME Code Case N-729-1, a direct visual examination of the bare metal surface of the entire outer surface of the head, including essentially 100% of the intersection of each nozzle with the head (J-groove). For coverage requirements see Figure 1 of Code Case N-729-1. For additional information reference QA-513J (ER-MNS-09-06). Acceptance criteria specified in ASME Code Case N-729-1 subject to the conditions in 1 OCFR 50.55a (g)(6)(ii)(D)(2) through (6). Relevant conditions for the purpose of the VE shall include areas of corrosion, boric acid deposits, discoloration, and other evidence of nozzle leakage. If EDY<8 and no flaws unacceptable for continued service have been detected, the reexamination frequency may be extended to every third refueling outage or 5 calendar years, whichever is less, provided an IWA-2212 VT-2 visual examination of the head is performed under the insulation through multiple access points in outages that the VE is not completed. Last Bare Metal Visual occurred during 2EOC17, so next full bare metal visual will be due in 2EOC20, provided EDY remains less than 8 and IWA-2212 VT-2 visuals are performed in every outage these VE's are not. EDY Calculation will continue to be updated and if EDY greater than or equal to 8 these VE's will be required every refueling outage, with no flexibility. Schedule Flexibility: Time between inspections may be shortened, but not lengthened. For additional information, contact Rachel Doss in the Materials and NDE Services Section, Nuclear Technical Services Division. This inspection replaces Augmented examinations M2.G5.1.0001 and M2.G5.2.0004 required by NRC Order EA-03-009. Once licensee implements this requirement the First Revised NRC Order EA-03-009 no longer applies and is deemed to be withdrawn.
Printed 06/07/11 GJU8302 v.06/18/09.C.M.2 0131 Peo SDQA Cat "C" McGuire 2 6/7/20116:33:01 AM.
Page 1 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Category AUG M2.G6.2.0001 Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Class I System Description Comments ThickINPS Cal Blocks Componenet ID 2 2PZR-Manway Class 1 NC MCM 1201.01-140 NDE-68 VT-2 Pressurizer Manway Pressurizer Manway Diaphram Seal Weld. Bare Metal Visual Exam by VT-2 qualified Inspector. Examine the gap between the Pressurizer Manway Cover and Manway for evidence of diaphram plate seal weld leakage. (For responsible Individual, contact J.M. Shuping, Alloy 600 Engineer Nuclear Technical Services). Reference NRC Bulletin 2004-01.
Category B-B M2.B2.11.0002 Circumferential 2PZR-5 Class 1 NC MCM 2201.01-15 MCM 2201.01-16 NDE-640 UT CS 3.750 / N/A 50337 B02.01 1.00; Head to Shell PRESSURIZER UPPER HEAD TO SHELL.
This exam was moved from 2EOC-19 to 2EOC-20, to provide time to schedule Westinghouse to be on standby to perform analysis on weld if required. Reference Note from Rick Branch dated 8/13/2009 requesting rescheduling of weld.
Drawing EDSK 379624B in Manual MCM 1201.01-0371 shows 3.750 min. wall at weld.
M2.B2.11.0002 2PZR-5 Class 1 Circumferential NC MCM 2201.01-15 MCM 2201.01-16 NDE-820 UT CS 3.750 / N/A 50337 B02.01 1.00; Head to Shell PRESSURIZER UPPER HEAD TO SHELL.
This exam was moved from 2EOC-19 to 2EOC-20, to provide time to schedule Westinghouse to be on standby to perform analysis on weld if required. Reference Note from Rick Branch dated 8/13/2009 requesting rescheduling of weld.
Drawing EDSK 379624B in Manual MOM 1201.01-0371 shows 3.750 min. wall at weld.
M2.B2.12.0002 Longitudinal 2PZR-9 Class 1 NC MCM 2201.01-15 MCM 2201.01-16 NDE-640 UT CS 3.750 / N/A 50337 B02.012.00; Head to Shell PRESSURIZER UPPER HEAD TO SHELL.
This exam was moved from 2EOC-19 to 2EOC-20, to schedule exam to be done in conjunction with 2PZR-5 (M2.B2.11.0002).
Drawing EDSK 379624B in Manual MCM 1201.01-0371 shows 3.750 min. wall at weld.
M2.B2.12.0002 2PZR-9 Class 1 NC MCM 2201.01-15 Longitudinal MCM 2201.01-16 NDE-820 UT CS 3.750 / N/A 50337 B02.012.00; Head to Shell PRESSURIZER UPPER HEAD TO SHELL.
This exam was moved from 2EOC-19 to 2EOC-20, to schedule exam to be done in conjunction with 2PZR-5 (M2.B2.11.0002).
Drawing EDSK 379624B in Manual MCM 1201.01-0371 shows 3.750 min. wall at weld.
Printed 06/07111 GJU8302
- v. 06/18/09 SDQA Cat "C" McGuire 2 6/712011 6:33:01 AM Page 2 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Class I System Procedure Insp Req Material Sched Thick/NPS Description Comments Cal Blocks Componenet ID 2 Category B9-D M2.B3.140.0007 Circumferential 2SGD-INLET Class 1 NC MCM 2201.01-0207 MCM 2201.01-0216 MCM 2201.01-0126 NDE-680 UT CS 6.250/31 I.D.
50235 B03.140.00; Nozzle To Head STEAM GENERATOR 2D INLET NOZZLE TO LOWER HEAD. Y1-X1 QUADRANT. (INSIDE RADIUS SECTION).
Drawing MCM 2201.01-0126 shows 6.250 min. wall at weld.
This item changed from VT-1 to UT because greater than 90% coverage can now be achieved using UT.
M2.B3.140.0008 2SGD-(
Class 1 Circumferential OUTLET NC MCM 2201.01-0207 NDE-680 UT CS 6.250/ 311.D.
50235 B03.140.00i MCM 2201.01-0216 MCM 2201.01-0126 Nozzle To Head STEAM GENERATOR 2D OUTLET NOZZLE TO LOWER HEAD. Y2-X1 QUADRANT. (INSIDE RADIUS SECTION).
Drawing MCM 2201.01-0126 shows 6.250 min. wall at weld.
This item changed from VT-1 to UT because greater than 90% coverage can now be achieved using UT.
Category B-O M2.B14.10.0017 2RPV-CRDM-69 Class 1 NC MCM 2201.01-20/sht.7 MCM 2201.01-0001 MC-ISIN3-2553-01.00 NDE-35 PT SS-Inconel 0.642 / 4.000 B14.010.01!
Adapter To Housing Body CRD HOUSING WELD. (PERIPHERAL)
Shroud has to be lifted to inspect see W/O 1923497-10 and 13.
Category C-A M2.C1.10.0005 Circumferential 2ASWINJF-2 Class 2 NV MCM 1201.04-27 MC-ISIN3-2554-03.00 NDE-3630 UT SS 0.438 / 4.500 50424 C01.010.10, SHELL to LOWER FLANGE SEAL WATER INJECTION FILTER 2A.
SDQA Cat "C" Printed 06/07/11 GJU8302 v. 06/18/09 McGuire 2 6/7/2011 6:33:01 AM Page 3 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M2.C1.10.0008 2RHR-2B-3-4 Class 2 ND MCM 1201.06-22 NDE-68 VT-2 SS 0.750 / 35.750 C011.010.2559, C01.010.256(
Circumferential MC-ISIN3-2561-01.00 NOZZLE BELT to Flange RESIDUAL HEAT REMOVAL HEAT EXCHANGER 2B.
Residual Heat Removal Heat Exchanger 2B Nozzle Belt to Flange Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Residual Heat Removal Heat Exchanger 2B is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2561-01.00 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
M2.Cl.10.0009 2RHRHX-2A-3-4 Class 2 ND MCM 1201.06-22 NDE-68 VT-2 SS 0.750 / 35.750 C01.010.05(
Circumferential MC-ISIN3-2561-01.00 NOZZLE BELT to Flange RESIDUAL HEAT REMOVAL HEAT EXCHANGER 2A.
Residual Heat Removal Heat Exchanger 2A Nozzle Belt to Flange Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Residual Heat Removal Heat Exchanger 2A is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2561-01.00 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
Printed 06/07/11 GJUB302
- v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 4 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThickJNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M2.C1.20.0014 2RHR-2B-2-3 Class 2 ND MCM 1201.06-22 NDE-68 VT-2 SS 0.750 / 37.250 C01.020.2561, C01.020.256, Circumferential MC-ISIN3-2561-01.00 NOZZLE BELT to HEAD RESIDUAL HEAT REMOVAL HEAT EXCHANGER 2B.
Residual Heat Removal Heat Exchanger 2B Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Residual Heat Removal Heat Exchanger 2B is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2561-01.00and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
M2.Cl.20.0018 2RHRHX-2A-2-3 Class 2 ND MCM 1201.06-22 NDE-68 VT-2 SS 0.750 / 35.750 C01.020.03(
Circumferential MC-ISIN3-2561-01.00 NOZZLE BELT to HEAD RESIDUAL HEAT REMOVAL HEAT EXCHANGER 2A.
Residual Heat Removal Heat Exchanger 2A Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Residual Heat Removal Heat Exchanger 2A is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2561-01.00 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
Printed 06/07/11 GJU8302
- v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 5 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Category C-A M2.C1.20.0019 Circumferential Component ID ISOIDWG Numbers Class I System 2REGHX-1-HD1 Class 2 NV MCM 1201.06-054 MC-ISIN3-2554-01.02 MCM 1201.06-015 Procedure Insp Req Material Sched Description Comments Thick/NPS Cal Blocks Componenet ID 2 NDE-68 VT-2 SS 1.075 / 10.920 COl.020.07(
NOZZLE BELT to HEAD REGENERATIVE HEAT EXCHANGER. (SHELL 1)0 EOC-1 7 report references RFR to be submitted for this exam. Implementation of Code Case N-706 will be used in place of RFR for this outage.
Regenerative Heat Exchanger (Shell 1) Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternatine exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015.
A VT-2 visual exam will be performed for this weld.
SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 6 of 23 Printed 06/07/11 GJU8302 v. 06/18/09
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M2.C1.20.0020 2REGHX-1-HD2 Class 2 NV MCM 1201.06-054 NDE-68 VT-2 SS 1.075 / 10.920 C01.020.01" Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 SHELL to HEAD REGENERATIVE HEAT EXCHANGER. (SHELL 1)
EOC-17 report references RFR to be submitted for this exam. Implementation of Code Case N-706 will be used in place of RFR for this outage.
Regenerative Heat Exchanger (Shell 1) Shell to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos.
MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
M2.Cl.20.0021 2REGHX-2-HD1 Class 2 NV MCM 1201.06-054 NDE-68 VT-2 SS 1.075 / 10.920 C01.020.07, Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 NOZZLE BELT to HEAD REGENERATIVE HEAT EXCHANGER. (SHELL 2)0 Regenerative Heat Exchanger (Shell 2) Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an altematine exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
Printed 06/07/11 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 7 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Class I System Procedure Insp Req Material Sched Description Comments ThickINPS Cal Blocks Componenet ID 2 Category C-A M2.C1.20.0022 Circumferential 2REGHX-2-HD2 Class 2 NV MCM1201.06-054 MC-ISIN3-2554-01.02 MCM 1201.06-015 NDE-68 VT-2 SS 1.075 / 10.920 C01.020.07' SHELL to HEAD REGENERATIVE HEAT EXCHANGER. (SHELL 2)0 Regenerative Heat Exchanger (Shell 2) Shell to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos.
MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-011.02 and Plan Addendum M2-PT-015.
A VT-2 visual exam will be performed for this weld.
M2.Cie.20.0023 Circumferential 2REGHX-3-HD1 Class 2 NV MCM 1201.06-054 MC-ISIN3-2554-01.02 MCM 1201.06-015 NDE-68 VT-2 SS 1.075 1 10.920 C01.020.074 NOZZLE BELT to HEAD REGENERATIVE HEAT EXCHANGER. (SHELL 3)[1 Regenerative Heat Exchanger (Shell 3) Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternatine exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015 A VT-2 visual exam will be performed for this weld.
Printed 06/07/11 GJU8302
- v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 8 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Class I System Procedure Insp Req Material Sched Description Comments Thick/NPS Cal Blocks Componenet ID 2 Category C-A M2.Cl.20.0024 2REGHX-3-HD2 Class 2 NV MCM 1201.06-054 Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 NDE-68 VT-2 SS 1.075 / 10.920 C01.020.07!
SHELL to HEAD REGENERATIVE HEAT EXCHANGER. (SHELL 3)0 Regenerative Heat Exchanger (Shell 3) Shell to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos.
MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015.
A VT-2 visual exam will be performed for this weld.
M2.C1.30.0007 2BCSHX-50-B Class 2 NS Circumferential MCM 1201.06-0093 MC-ISIN3-2563-01.00 MCM 1201.06-0090 NDE-3630 UT SS 0.437 / 55.375 50420 C01.030.01' SHELL to BOTTOM TUBESHEET CONTAINMENT SPRAY HEAT EXCHANGER 2B.
M2.C1.30.0008 Circumferential 2BCSHX-50-A Class 2 NS MCM 1201.06-0093 MC-ISIN3-2563-01.00 MCM 1201.06-0090 NDE-3630 UT SS 0.437 / 55.375 50420 C01.030.01; SHELL to TOP TUBESHEET CONTAINMENT SPRAY HEAT EXCHANGER 2B.
SDQA Cat "C" Printed 06/07/11 GJU8302 v. 06/18/09 McGuire 2 6/7/2011 6:33:01 AM Page 9 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC.20)
Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M2.Cl.30.0015 2REGHX-2-TS-SH Class 2 NV MCM 1201.06-054 NDE-68 VT-2 SS 1.075 10.920 C01.030.02=
Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 TUBESHEET to SHELL REGENERATIVE HEAT EXCHANGER. (SHELL 2)
Regenerative Heat Exchanger (Shell 2) Tubesheet to Shell. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-01 5. A VT-2 visual exam will be performed for this weld.
M2.C1.30.0016 2REGHX-3-NB-TS Class 2 NV MCM 1201.06-054 NDE-68 VT-2 SS 1.075 / 10.920 C01.030.02d Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 NOZZLE BELT to TUBESHEET REGENERATIVE HEAT EXCHANGER. (SHELL 3)
Regenerative Heat Exchanger (Shell 3) Nozzle Belt to Tubesheet. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
Printed 06/07/11 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 10 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class / System Description Comments Category C-A M2.Cl.30.0017 2REGHX-3-TS-SH Class 2 NV MCM 1201.06-054 NDE-68 VT-2 SS 1.075 / 10.920 C01.030.02!
Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 TUBESHEET to SHELL REGENERATIVE HEAT EXCHANGER. (SHELL 3)
Regenerative Heat Exchanger (Shell 3) Tubesheet to Shell. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
M2.C1.30.0018 2REGHX-1-NB-TS Class 2 NV MCM 1201.06-054 NDE-68 VT-2 SS 1.075 / 10.920 C01.030.02(
Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 NOZZLE BELT to TUBESHEET REGENERATIVE HEAT EXCHANGER. (SHELL 1)
EOC-17 report references RFR to be submitted for this exam. Implementation of Code Case N-706 will be used in place of RFR for this outage.
Regenerative Heat Exchanger (Shell 1) Nozzle Belt to Tubesheet. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code# 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
Printed 06/07/11 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 11 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M2.C1.30.0019 2REGHX-1-TS-SH Class 2 NV MCM 1201.06-054 NDE-68 VT-2 SS 1.075 / 10.920 C011.030.02" Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 TUBESHEET to SHELL REGENERATIVE HEAT EXCHANGER. (SHELL 1)
EOC-17 report references RFR to be submitted for this exam. Implementation of Code Case N-706 will be used in place of RFR for this outage.
Regenerative Heat Exchanger (Shell 1) Tubesheet to Shell. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code # 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-0115. A VT-2 visual exam will be performed for this weld.
M2.C1.30.0020 2REGHX-2-NB-TS Class 2 NV MCM 1201.06-054 NDE-68 VT-2 SS 1.075 / 10.920 C01.030.02; Circumferential MC-ISIN3-2554-01.02 MCM 1201.06-015 NOZZLE BELT to TUBESHEET REGENERATIVE HEAT EXCHANGER. (SHELL 2)
Regenerative Heat Exchanger (Shell 2) Nozzle Belt to Tubesheet. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and File Nos. MC-1212.04, MC-1223.04, and MC-1223.11 (Record Retention Code# 000252).
If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected.
This exam will be performed under the Pressure Test Program, reference McGuire Third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISIL-2554-01.02 and Plan Addendum M2-PT-015. A VT-2 visual exam will be performed for this weld.
Printed 06/07/11 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 12 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Category C-C M2.C3.10.0011 Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Class I System Description Comments ThickINPS Cal Blocks Componenet ID 2 2RCHPSS-SUPPORT Class 2 NV MCM 1201.04-272 MC-ISIN3-2554-03.00 NDE-35 PT SS 0.375 / 0.000 C03.010.00(
RECIPROCATING CHRGING PUMP SUCTION STABILIZER SUPPORT. WELDED ATTACHMENT.
M2.C3.20.0016 Mech Snubber 2MCA-ND-6109 Class 2 ND MCSRD-2ND-350/sht. 7 MC-ISIN3-2561-01.00 2MCA-ND-6109 NDE-35 PT SS 0.125 / 8.000 C03.020.263(
Mech Snubber This item was exchanged with M2.C3.20.0001 2MCA-ND-6123, interference for that support made this change necessary.
Welded Attachment. Inspect with M2.F1.20.0359.
The Thickness 0.125 listed is a reference used to identify support as having a welded attachment since thickness can't be determined using the support sketch. If exact dimension is needed a field measurement will be required.
M2.C3.20.0021 Rigid Restraint 2MCA-ND-6117 Class 2 ND MCSRD-2ND-350/sht. 7 MC-ISIN3-2561-01.00 2MCA-ND-6117 NDE-35 PT SS 0.154 /8.000 C03.020.02ý Rigid Restraint WELDED ATTACHMENT. INSPECT WITH F01.020.122B.
Category D-A M2.D1.10.0009 Rigid Support 2MBD-SUPPORT-2A Class 3 NV MCM 2201.09-0008 MC-ISIN3-2554-04.00 NDE-65 VT-1 NA 0.250 / 0.000 D01.010.00' Rigid Support MIXED BED DEMINERALIZER 2A SUPPORT. WELDED ATTACHMENT. INSPECT WITH M2.F1.40.0094.
Item was exempted in second interval per Engineering notethat allowed a temperature and pressure exemption. Reference PIP M-06-2995 This item was rescheduled from 2EOC-18 to 2EOC-19 per Plan Addendum 2MNS-036. The Mixed Bed Demineralizer is surrounded in lead, this is rescheduled to allow the station time to prepare for examination during EOC-19, reference WO 1748102/03 and PIP M-08-03046.
Code Case N-700 requires only one welded attachment on a component to be examined. On drawing MCM 2201.09.0008 examine one support leg to vessel weld, facing tank and item #10 examine support on the right hand side (also lined up with lifting lug). Reference PIP G-08-00499 ACA#2 and CA#5.
This exam moved from EOC-19 to EOC-20 per station request per note dated September 3, 2009. This is to align the exam with sluice by Chemistry and the 36 Month PM. Work order needs to be created to address this exam.
Printed 06/07/11 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 2 6/712011 6:33:01 AM Page 13 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Category D-A M2.D1.20.0003 Rigid Support Category F-A Component ID ISOIDWG Numbers Procedure Insp Req Material Class I System Description Comments Sched Thick/NPS Cal Blocks Componenet ID 2 2MCA-RN-3086 Class 3 RN MCSRD-2RN-351/sht. 2 MC-ISIN-2574-03.01 2MCA-RN-3086 NDE-65 VT-1 NA 0.375 / 18.000 D01.020.01" Rigid Support Inspect with M2.F1.30.0049
- r.
M2.F1.10.0041 2MCR-NV-4443 Class 1 NV MCSRD-2NV-204/sht. 1 NDE-66 VT-3 NA 0.000 / 2.000 F01.010.102/
Rigid Support Rigid Support M2.F1.10.0042 2MCR-NV-4438 Class 1 NV MCSRD-2NV-204/sht. 1 NDE-66 VT-3 NA 0.000 1 3.000 FO1.010.103/
Rigid Support Rigid Support M2.F1.20.0022 Mech Snubber M2.F1.20.0023 Spring Hgr M2,F1.20.0024 Hyd Snubber M2.F1.20.0040 Rigid Restraint 2MCA-FW-5009 Class 2 FW MCSRD-2FW-350/sht. 1 2MCA-FW-5160 Class 2 FW MCSRD-2FW-350/sht. 2 NDE-66 VT-3 NA 0.000 / 24.000 F011.020.07813, F0l.020.078C Mech Snubber NDE-66 VT-3 NA 0.000 / 24.000 F01.020.079C Spring Hgr 2MCA-FW-5180 Class 2 FW MCSRD-2FW-350/sht. 2 2MCA-ND-6108 Class 2 ND MCSRD-2ND-350/sht. 1 NDE-66 VT-3 NA 0.000 / 24.000 F01.020.080C Hyd Snubber NDE-66 VT-3 NA 0.000 / 8.000 F01.020.108E Rigid Restraint Printed 06/07/11 GJU8302
- v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 14 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Class I System Description Comments Category F-A M2.F1.20.0054 2MCA-ND-6117 Class 2 ND MCSRD-2ND-350/sht. 7 NDE-66 VT-3 NA 0.154 / 8.000 Rigid Restraint Rigid Restraint INSPECT WITH C03.020.023.
M2.F1.20.0108 2MCA-NS-5305 Class 2 NS MCSRD-2NS-352/sht. 1 NDE-66 VT-3 NA 0.000 /10.000 Rigid Restraint Rigid Restraint M2.F1.20.0109 2MCA-NS-5308 Class 2 NS MCSRD-2NS-352/sht. 2 NDE-66 VT-3 NA 0.000 / 8.000 Rigid Restraint Rigid Restraint M2.F1.20.0316 2MCA-ND-5609 Class 2 ND MCSRD-2ND-350/sht. 4 NDE-66 VT-3 NA 0.125 /8.000 Rigid Support Rigid Support M2.F1.20.0359 2MCA-ND-6109 Class 2 ND 2ND-350(SHT.7OF7)
NDE-66 VT-3 NA 0.000 / 8.000 Mech Snubber Mech Snubber Inspect with M2.C3.20.0016.
M2.F1.20.0521 2MCA-NV-5036 Class 2 NV MCSRD-2NV-350/sht. 1 NDE-66 VT-3 NA 0.000 / 3.000 Rigid Support Rigid Support M2.F1.20.0844 2MCR-NI-4107 Class 2 NI MCSRD-2NI-209/sht. 1 NDE-66 VT-3 NA 0.000 / 4.000 Rigid Support Rigid Support Cal Blocks Componenet ID 2 F01.020.122E F01.020.224E F01.020.225E F01.020.131A, F01.020.653-F01.020.6619, F01.020.662(
F0l.020.264A, F01.020.691' F01.020.189A, FO1.020.748 Printed 06/07/11 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 15 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISO/DWG Numbers Class I System Procedure Insp Req Description Comments Material Sched Thick/NPS Cal Blocks Componenet ID 2 Category F-A M21F1.20.1139 Mech Snubber 2-MCA-S-NI-504-1-L Class 2 NI 2-MCA-S-NI-504-1 NDE-66 VT-3 NA 0.000 / 2.000 F01.020.179C Mech Snubber M2.F1`.20.1140 Rigid Support M2.F1.30.0047 Rigid Restraint 2-MCA-S-NI-504-1 -K Class 2 NI 2-MCA-S-NI-504-1 NDE-66 VT-3 NA 0.000 / 2.000 F01.020.180/
_____________Rigid Support 2MCA-RN-3028 Class 3 RN MCSRD-2RN-351/sht. 1 NDE-66 VT-3 NA 0.000 / 20.000 F01.030.154E Rigid Restraint M2.F1.30.0048 2MCA-RN-3083 Class 3 RN MCSRD-2RN-351/sht. 2 Rigid Restraint M2.F1.30.0049 2MCA-RN-3086 Class 3 RN MCSRD-2RN-351/sht. 2 NDE-66 VT-3 NA 0.594 /18.000 F01.030.155E Rigid Restraint NDE-66 VT-3 NA 0.375 / 18.000 F01.030.156A, F01.030.157/
Rigid Support Inspect with M2.1)1.20.0003 M2.F1.30.0403 Rigid Support 2MCA-KD-3130 Class 3 KD MCSRD-2KD-353/sht. 1 NDE-66 VT-3 NA 0.000 / 6.000 F01.030.102A, F01.030.858.
Rigid Support M2.F1`.30.0407 Mech Snubber 2MCA-KD-3144 Class 3 KD MCSRD-2KD-353/sht. 2 NDE-66 VT-3 NA 0.000 / 6.000 F01.030.103C, F01.030.858(
Mech Snubber Printed 06/07/11 GJU8302
- v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 16 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISO/DWG Numbers Class I System Procedure Insp Req Material Sched Thick/NPS Description Comments Cal Blocks Componenet ID 2 Category F-A M2.F1.40.0094 Rigid Support 2MBD-SUPPORT-2A Class 3 NV MCM 2201.09-0008 MC-ISIN3-2554-04.00 NDE-66 VT-3 NA 0.250 / 0.000 F01.040.011V Rigid Support MIXED BED DEMINERALIZER 2A SUPPORT. Inspect with M2.D1.10.0009 This item was rescheduled from 2EOC-18 to 2EOC-19 per Plan Addendum 2MNS-036. The Mixed Bed Demineralizer is surrounded in lead, this is rescheduled to allow the station time to prepare for examination during EOC-19, reference WO 1748102/03 and PIP M-08-03046.
This exam moved from EOC-19 to EOC-20 per station request per note dated September 3, 2009. This is to align the exam with sluice by Chemistry and the 36 Month PM. Work order needs to be created to address this exam.
M2.F1.40.0110 Rigid Restraint Category R-A M2.R1.1 1.0090 Circumferential 2RNP-SUPPORT-2B Class 3 RN MCM 1201.05-190 MC-ISIN3-2574-01.01 NDE-66 VT-3 NA 0.000 / 0.000 F01.040.023E Rigid Restraint NUCLEAR SERVICE WATER PUMP 2B SUPPORT.
2NV2FW 183-4 Class 2 NV MCFI-2NV183 MC-ISIN-2554-01.00 Risk Segment NV-020GP R01.011.14' NDE-12 RT SS 0.344 /2.000 Pipe to Reducer This weld has been verified by NDE Level III looking at the construction RT film to be a butt weld. Due to weld configuration UT is not possible, RT can be performed and about 80% coverage can be obtained. Work order needs to be generated to schedule RT of this weld during EOC-20.
Examination to be done with M2.R1.16.0039.
M2.R1.11.0092 2NV2FW54-18 Class 2 NV MCFI-2NV54 MC-ISIN-2554-03.00 Risk Segment NV-06, R01.011.14!
PDI-UT-2 UT SS 0.438 / 3.000 PDI-UT-2-C 50225 PDI-UT-2A-M Circumferential Tee to Pipe Examination to be done with M2.R1.16.0022.
Printed 06/07/11 GJU8302
- v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 17 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Class I System Category R-A M2.R1.11.0093 2NV2FW116-21 Class 2 NV MCFI-2NV1 16 MC-ISIN-2554-01.02 Procedure Insp Req Material Sched Description Comments Thick/NPS Cal Blocks Componenet ID 2 Risk Segment NV-077E R01.011.14(
PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C 8279-0410 PDI-UT-2A-M Circumferential Reducer to Pipe Examination to be done with M2.R1.16.0023.
M2.R1. 11.0276 2NV2FW216-60 Class 2 NV MCFI-2NV216 MC-ISIN-2554-01.02 Risk Segment NV-084A R01.011.15" PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2A-M PDI-UT-2-C 8279-0410 Circumferential Pipe To Pipe M2.R1.11.1538 2NV2FW33-23 Class 2 NV MCFI-2NV33 MC-ISIN-2554-03.00 Risk Segment NV-002E R01.011.13" PDI-UT-2 UT SS 0.237 1 4.000 PDI-UT-2-C 8279-0416 PDI-UT-2A-M Circumferential Pipe to Elbow Examination to be done with M2.R1.16.001 1.
M2.R1.11.156 4 2NV2FW179-31 Class 2 NV MCFI-2NV179 MC-ISIN-2554-01.01 Risk Segment NV-020C, R01.011.14" PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C 8279-0410 PDI-UT-2A-M Circumferential M2.R1.11.1593 Circumferential Pipe to Reducer Examination to be done with M2.R1.16.0020.
2NV2FW183-29 Class 2 NV MCFI-2NV183 MC-ISIN-2554-01.01 Risk Segment NV-020E, R01.011.14.
NDE-12 RT SS 0.344 / 2.000 Pipe to Reducer This weld has been verified by NDE Level III looking at the construction RT film to be a butt weld. Due to weld configuration UT is not possible, RT can be performed and about 80% coverage can be obtained. Work order needs to be generated to schedule RT of this weld during EOC-20.
Examination to be done with M2.R1.16.0038.
Printed06/07/11 JU8302 v.06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 18 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Class I System Description Comments Thick/NPS Cal Blocks Componenet ID 2 Category R-A M2,R1.11.1595 2NV2FW216-57 Class 2 NV MCFI-2NV216 MC-ISIN-2554-01.02 Risk Segment NV-081 R01.011.141 PDI-UT-2 UT SS 0.436 / 2.000 PDI-UT-2-C 8279-0411 PDI-UT-2A-M Circumferential M2.R1.11.1596 Pipe To Pipe Examination to be done with M2.R1.16.0024.
2NV2FW2 16-53 Class 2 NV MCFI-2NV216 PDI-UT-2 UT SS MC-ISIN-2554-01.02 Risk Segment NV-082 R01.011.14, 0.436 / 2.000 PDI-UT-2-C 8279-0411 PDI-UT-2A-M Circumferential Pipe To Pipe
_____________Examination to be done with M2.R1.16.0025.
M2.R1.11.1597 2NV2FW216-52 Class 2 NV MCFI-2NV216 MC-ISIN-2554-01.02 Risk Segment NV-082 R01.011.15(
PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C 8279-0410 PDI-UT-2A-M Circumferential Pipe To Pipe Examination to be done with M2.R1.16.0026.
M2.R1.16.0011 2NV2FW33-23 Class 2 NV MCFI-2NV33 MC-ISIN-2554-03.00 Risk Segment NV-002E PDI-UT-2 UT SS 0.237 / 4.000 PDI-UT-2-C 8279-0416 PDI-UT-2A-M Pipe to Elbow This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.
Examination to be done with M2.R1.11.1538.
Printed 06/07/11 GJU8302 v. 06118/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 19 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISOIDWG Numbers Class I System Procedure Insp Req Material Sched Description Comments Thick/NPS Cal Blocks Componenet ID 2 Category M2.R1.16.C R-A 0020 2NV2FW179-31 Class 2 NV MCFI-2NV179 MC-ISIN-2554-01.01 Risk Segment NV-020CP PDI-UT-2 UT SS 0.344 / 2.000 8279-0410 PDI-UT-2-C PDI-UT-2A-M Pipe to Reducer This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.
Examination to be done with M2.R1.11.1564.
Risk Segment NV-06!
M2.R1.16.0022 2NV2FW54-18 Class 2 NV MCFI-2NV54 MC-ISIN-2554-03.00 PDI-UT-2 UT SS 0.438 / 3.000 PDI-UT-2-C 50225 PDI-UT-2A-M Tee to Pipe This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.
Examination to be done with M2.R1.11.0092.
Risk Segment NV-077E M2.R1.16.0023 2NV2FW1 16-21 Class 2 NV MCFI-2NV116 MC-ISIN-2554-01.02 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C 8279-0410 PDI-UT-2A-M Reducer to Pipe This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.
Examination to be done with M2.R1.11.0093.
M2.R1.16.0024 2NV2FW216-57 Class 2 NV MCFI-2NV216 MC-ISIN-2554-01.02 Risk Segment NV-081 PDI-UT-2 UT SS 0.436 / 2.000 PDI-UT-2-C 8279-0411 PDI-UT-2A-M Pipe To Pipe This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.
Examination to be done with M2.R1.11.1595.
Printed 06/07/11 GJU8302
- v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 20 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Component ID ISO/DWG Numbers Class I System Procedure Insp Req Material Sched Thick/NPS Description Comments Cal Blocks Componenet ID 2 Category R-A M2.R1.16.0025 2NV2FW216-53 Risk Segment NV-082 Class 2 NV MCFI-2NV216 PDI-UT-2 UT SS 0.436 / 2.000 PDI-UT-2-C MC-ISIN-2554-01.02 8279-0411 PDI-UT-2A-M Pipe To Pipe This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.
Examination to be done with M2.RI.11.1596.
M2.R1.16.0026 2NV2FW216-52 Risk Segment NV-082 Class 2 NV MCFI-2NV216 MC-ISIN-2554-01.02 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C 8279-0410 PDI-UT-2A-M Pipe To Pipe This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.
Examination to be done with M2.R1.11.1597.
M2.Rl.16.0032 2NV2FW27-2 Class 2 NV MCFI-2NV27 MC-ISIN-2554-03.01 Risk Segment NV-001 PDI-UT-2 UT SS 0.148 / 8.000 8279-0415 PDI-UT-2-C PDI-UT-2A-M Elbow to Pipe Reference PIP M-08-00778. For this weld to be examined valve 2NV223 must be disassembled to allow for the draining of pipe.
This evaluation was made with the concurrence of the Operations Technical Group.
This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program. Procedure PDI-UT-2 to be used reference PIP M-1 0-3538.
(NOTE) This exam was performed under Summary Number M2.R1.11.1532 during EOC-19. UT examination will be performed during EOC-20 for this summary number.
Printed 06/07/11 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 2 6/7/2011 6:33:01 AM Page 21 of 23
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20)
Summary Num Category R-A M2,Ri,16,0033 Component ID ISO/DWG Numbers Class I System 2NV2FW1 15-5 Class 2 NV MCFI-2NV115 MC-ISIN-2554-03.01 Procedure Insp Req Material Sched Description Comments Thick/NPS Cal Blocks Componenet ID 2 Risk Segment NV-002AP PDI-UT-2 UT SS 0.148 /8.000 8279-0415 PDI-UT-2-C PDI-UT-2A-M This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program. Procedure PDI-UT-2 to be used reference PIP M-1 0-3538.
(NOTE)
This exam was performed under Summary Number M2.RI.11.0189 during EOC-18. UT examination will be performed during EOC-20 for this summary number.
M2.R1.16.0034 2NV2FW115-4 Class 2 NV MCFI-2NV115 MC-ISIN-2554-03.01 Risk Segment NV-002A, PDI-UT-2 UT SS 0.148/8.000 8279-0415 PDI-UT-2-C PDI-UT-2A-M Elbow to Pipe This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program. Procedure PDI-UT-2 to be used reference PIP M-10-3538.
(NOTE)
This exam was performed under Summary Number M2.R1.11.1534 during EOC-18. UT examination will be performed during EOC-20 for this summary number.
M2.R1.16.0038 2NV2FW183-29 Class 2 NV MCFI-2NV183 MC-ISIN-2554-01.01 Risk Segment NV-020EA NDE-12 RT SS 0.344 / 2.000 Pipe to Reducer This weld has been verified by NDE Level III looking at the construction RT film to be a butt weld. Due to weld configuration UT is not possible, RT can be performed and about 80% coverage can be obtained. Work order needs to be generated to schedule RT of this weld during EOC-20.
This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program. Procedure NDE-12 to be used reference PIP M-10-3538.
Examination to be done with M2.R1.11.1593.
.SDQA Cat "C" McGuire 2.6/7/2011 6:33:01 AM Pa.e 22 Printe 06/7/1 "CU0 vc.ir 06180 6//01:30 M
Pg 23 Printed 06/07/11 GJU8302 v. 06/18/09 v
f 23
Summary Num Component ID ISO/DWG Num Class I System Category R-A M2.RI.16.0039 2NV2FW183-4 Class 2 NV MCFI-2NV183 MC-ISIN-2554-01.
This report includes all changes through addendum 2MNS-074 McGuire 2, 3rd Interval, outage 5 (EOC-20) bers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Description Comments Risk Segment NV-020GP NDE-12 RT SS 0.344 / 2.000 00 Pipe to Reducer This weld has been verified by NDE Level III looking at the construction RT film to be a butt weld. Due to weld configuration UT is not possible, RT can be performed and about 80% coverage can be obtained. Work order needs to be generated to schedule RT of this weld during EOC-20.
This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program. Procedure NDE-12 to be used reference PIP M-10-3538.
Examination to be done with M2.R1.11.0090.
End of Report Class 1 12 Class 2 57 Class 3 9 Total by Class 78 Systems 78 Total Count 78 S TA TIS TICS ONL Y Printed 06/07/11 GJU8302 v. 06/18/09 SDQA Cat "C "
McGuire 2 6/7/2011 6:33:01 AM Page 23 of 23
4.0 Results of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.
4.1 Reportable Indications EOC 20 (Outage 5) had no reportable indications during this report period.
4.2 Corrective Action Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair /
replacement activities, and corrective measures.
There was no corrective action for the examinations associated with this report period.
4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities.. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke's Corporate Office in Charlotte, North Carolina.
4.4 Limited Examinations Limitations (i.e., 90% or less of the required examination coverage obtained) identified for examinations associated with this report period are shown below.
A relief request will be submitted to seek NRC acceptance of the limited coverage. This information will be on file at the Duke's Corporate Office in Charlotte, North Carolina.
Item Number PIP Number M2.R1.11.0276 M-11-04257 EOC 20 Refueling Outage Report Page 1 of 1 McGuire Unit 2 Revision 0 Section 4 June 7, 2011
DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES Scheduleworks Inservice Inspection Database Management System Inspection Results McGuire 2, 3rd Interval, Outage 5 (EOC-20)
EOC 20 Report Results Summary No Component ID M2.B14.10.0017 2RPV-CRDM-69 System NC Insp Date 03/08/11 Insp Status CLR Insp Geo Limited Ref RFR Comment N
N N
PT-11-029 M2.1B15.80.0001 M2.B2.11.0002 2-RPV-BM I-NOZZLES NC 03/01/11 CLR N
N N
VT-11-526 NC 03/02/11 2PZR-5 CLR Y
N N
UT-1i1-151 (Page 1)
NC 03/02/11 REC Y
N N
UT-1i1-151 (Page 2)
Indications sized and evaluated to Table IWB-3510-1 and found to be acceptable. Slag indication no change from previous data.
Y N
N UT-11-151 (Page 3)
N N
N UT-11-165 M2.B2.12.0002 2PZR-9 NC NC NC NC NC NC 03/02/11 03/02/11 03/02/11 03/02/11 03/02/11 03/02/11 CLR CLR CLR CLR CLR CLR N
N N
N N
N N
N N
N N
N UT-1 1-149 (Page 1)
UT-11-149 (Page 2)
UT-11-149 (Page 3)
UT-11-166 M2,13.140.0007 2SGD-INLET NC NC 03/03/11 03/03/11 CLR CLR N
N N
N N
N UT-1l1-153 (Page 1)
UT-1i1-153 (Page 2)
Printed 617/2011 9:29:58 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 1 of 12
EOC 20 Report Results Insp Geo Insp Insp Summary No Component ID System Date Status Limited Ref RFR Comment M2.B3.140.0007 2SGD-INL M2.B3.140.0008 2SGD-OU M2.14.10.0001 2RPV-Hea M2.C1.10.0005 2ASWINJ M2.C1.10.0008 M2.C1.10.0009 M2.C1.20.0014 M2.C1.20.0018 M2.C1.20.0019 ET NC 03/03/11 CLR N
N N
UT-1l1-153 (Page 3)
TLET NC 03/03/11 CLR N
N N
UT-1l1-154 (Page 1)
NC 03/03/11 CLR N
N N
UT-1 1-154 (Page 2)
NC 03/03/11 CLR N
N N
UT-1 1-154 (Page 3) d NC 03/08/11 CLR N
N N
VT-1 1-531 F-2 NV 03/10/11 CLR N
Y N
UT-11-167 (Page 1)
Signal response indicated geometry (flange taper) 360 deg. intermitten.
NV 03/10/11 CLR N
N N
UT-11-167 (Page 2) 3-4 ND 02/24/11 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
2A-3-4 ND 02/03/11 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
2-3 ND 02/24/11 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
2A-2-3 ND 02/03/11 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
1-HD1 NV 04/02/11 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
2RHR-2B-2RHRHX-.
2RHR-2B-2RHRHX-2REGHX-Printed 6/7/2011 9:29:58 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 2 of 12
EOC 20 Report Results Insp Insp Geo Status Limited Ref RFR Comment Summary No M2.C1.20.0020 M2.C1.20.0021 Component ID 2REGHX-1 -HD2 2REGHX-2-HD1 Insp System Date NV 04/02/11 NV 04/02/11 CLR CLR N
N N
VT-n/a See Pressure Test Program for additional results.
N N
N VT-n/a See Pressure Test Program for additional results.
2REGHX-2-HD2 NV 04/02/11 M2.C1.20.0022 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
M2.C1.20.0023 2REGHX-3-HD1 NV 04/02/11 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
M2.C1.20.0024 2REGHX-3-HD2 NV 04/02/11 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
M2.C1.30.0007 2BCSHX-50-B NS 02/16/11 CLR N
Y N
UT-11-148 (Page 1)
Indications were determined to be geometry.
NS 02/16/11 CLR N
N N
UT-11-148 (Page 2)
M2.C1.30.0008 2BCSHX-50-A NS 02/16/11 CLR N
Y N
UT-11-147 (Page 1)
Indications were determined to be geometry.
NS 02/16/11 CLR NV 04/02/11 CLR N
N N
UT-11-147 (Page 2)
M2.C1.30.0015 2REGHX-2-TS-SH N
N N
VT-n/a See Pressure Test Program for additional results.
Printed 6/7/2011 9:29:58 AM GJU8302 v. 01 /01 /08 SDOA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 3 of 12
EOC 20 Report Results Insp Insp Insp Geo Date Status Limited Ref Summary No M2.C1.30.0016 M2.C1.30.0017 M2.C1.30.0018 M2.C1.30.0019 M2.C1.30.0020 Component ID 2REGHX-3-NB-TS 2REGHX-3-TS-SH 2REGHX-1 -NB-TS 2REGHX-1 -TS-SH System RFR Comment NV 04/02/11 NV 04/02/11 NV 04/02/11 NV 04/02/11 CLR N
N N
VT-n/a See Pressure Test Program for additional results.
CLR N
N N
VT-n/a See Pressure Test Program for additional results.
CLR N
N N
VT-n/a See Pressure Test Program for additional results.
CLR N
N N
VT-n/a See Pressure Test Program for additional results.
CLR N
N N
VT-n/a See Pressure Test Program for additional results.
CLR N.
N N
PT-11-026 CLR N
N N
PT-11-027 CLR N
N N
PT-11-028 CLR N
N N
VT-11-510 2REGHX-2-NB-TS M2.C3.10.0011 2RCHPSS-SUPPORT M2.C3.20.0016 2MCA-ND-6109 M2.C3.20.0021 2MCA-ND-6117 M2.D1.10.0009 2MBD-SUPPORT-2A M2.D1.20.0003 2MCA-RN-3086 M2.F1.10.0041 2MCR-NV-4443 NV 04/02/11 NV 02/10/11 ND 02/10/11 ND 02/10/11 NV 01/14/11 RN 02/21/11 NV 03/04/11 CLR CLR N
N N
N N
N VT-11-525 VT-1 1-533 Printed 6/7/2011 9:29:59 AM GJU8302 v. 01/01/08 McGuire 2 6/7/2011 9:29:17 AM SDQA Cat "C" Page 4 of 12
EOC 20 Report Results Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M2.Fl.10.0042 2MCR-NV-4438 NV 03/04/11 REC N
N N
VT-11-532 Spherical bearing at the pipe attached end of the strut is dislodged. Eng.
evaluation: Spherical bearing is out 1/4" from flush position, this has no adverse affects on tension, compression, no operability issue W/R 1029564 written to make correction.
M2.F1.20.0022 2MCA-FW-5009 FW 03/02/11 CLR N
N N
VT-11-529 M2.F1.20.0023 2MCA-FW-5160 FW 02/17/11 CLR N
N N
VT-11-528 M2.F1.20.0024 2MCA-FW-5180 FW 02/17/11 CLR N
N N
VT-11-530 M2.F1.20.0040 2MCA-ND-6108 ND 02/07/11 CLR N
N N
VT-11-513 M2.F1.20.0054 2MCA-ND-6117 ND 02/03/11 CLR N
N N'
VT-11-517 M2.F1.20.0108 2MCA-NS-5305 NS 02/10/11 CLR N
N N
VT-11-518 M2.F1.20.0109 2MCA-NS-5308 NS 02/10/11 CLR N
N N
VT-11-520 M2.F1.20.0316 2MCA-ND-5609 ND 02/07/11 CLR N
N N
VT-11-514 M2.F1.20.0359 2MCA-ND-6109 ND 02/07/11 CLR N
N N
VT-11-516 M2.F1.20.0521 2MCA-NV-5036 NV 03/19/11 CLR N
N N
VT-11-535 M2.F1.20.0844 2MCR-NI-4107 NI 03/04/11 CLR N
N N
VT-11-534 M2.F1.20.1139 2-MCA-S-NI-504-1-L NI 01/31/11 CLR N
N N
VT-11-511 Printed 6/7/2011 9:29:59 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 5 of 12
EOC 20 Report Results Insp Geo Insp Insp Summary No M2.F1.20.1140 M2.F1.30.0047 M2.F1.30.0048 M2.F1.30.0049 M2.F1.30.0403 M2.F1.30.0407 M2.F1.40.0094 M2.F1.40.0110 M2.G6.2.0001 M2.R1.11.0090 M2.R1.11.0092 Component ID 2-MCA-S-NI-504 2MCA-RN-3028 2MCA-RN-3083 2MCA-RN-3086 2MCA-KD-3130 2MCA-KD-3144 2MBD-SUPPORT-2 2RNP-SUPPORT-2 2PZR-Manway 2NV2FW183-4 2NV2FW54-18 System Date Status Limited Ref RFR Comment
-K NI 01/31/11 CLR N
N N
VT-11-512 RN 02/07/11 CLR N
N N
VT-1 1-515 RN 02/10/11 CLR N
N N
VT-11-519 RN 02/21/11 CLR N
N N
VT-11-524 KD 02/22/11 CLR N
N N
VT-11-523-KD 02/22/11 REC N
N N
VT-11-522 Snubber item #8 is lockedup, pipe is not bearing on support. Eng. evaluation:
Snubber is not lockedup W/O 1971210 and PIP M-11-1233 documents this, pipe bearing 1/64" or less, this is an acceptable gap. No operability issue 2A NV 01/14/11 CLR N
N N
VT-11-509 B
RN 02/16/11 CLR N
N N
VT-11-521 NC 03/01/11 REC N
N N
VT-11-527 Small accumulation of boron and crystals on interface of pressurizer and manway cover and bolting. Eng. evaluation determined powder to be insulation dust. Reference PIP M-11-1508 and W/R 01028856 NV 03/02/11 REC N
N N
RT-n/a Indication acceptable: Film artifacts and root edge NV 03/04/11 CLR Y
N N
UT-11-161 (Page 1)
Tee is a forged fitting configuration causing limitation Printed 6/7/2011 9:29:59 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 6 of 12
EOC 20 Report Results Insp Insp Insp Geo System Date Status Limited Ref Summary No M2.R1.11.0092 Component ID 2NV2FW54-18 RFR Comment NV 03/04/11 CLR NV 03/04/11 CLR NV 03/04/11 CLR NV 03/04/11 CLR Y
N N
UT-11-161 (Page 2)
Tee is a forged fitting configuration causing limitation Y
N N
UT-1 1-161 (Page 3)
Tee is a forged fitting configuration causing limitation Y
N N
UT-1 1-161 (Page 4)
Tee is a forged fitting configuration causing limitation Y
N N
UT-11-161 (Page 5)
Tee is a forged fitting configuration causing limitation M2.R1.1 1.0093 2NV2FW1 16-21 NV NV 02/08/11 02/08/11 CLR CLR CLR CLR N
N N
N N
N N
N UT-11-141 (Page 1)
UT-11-141 (Page 2)
UT-1 1-141 (Page 3)
UT-11-141 (Page 4)
NV 02/08/11 NV 02/08/11 N
N N
N M2.R1.11.0276 2NV2FW216-60 NV 03/01/11 CLR CLR Y
N Y
UT-11-159 (Page 1)
Limitation due to welded pipe support PIP M-11-04257 was written to determine the corrective action for the limited coverage obtained for this item.
Y N
Y UT-1l1-159 (Page 2)
Limitation due to welded pipe support PIP M-1 1-04257 was written to determine the corrective action for the limited coverage obtained for this item.
NV 03/01/11 M2.R1.11.1538 2NV2FW33-23 NV 02/08/11 NV 02/08/11 Printed 6/7/2011 9:29:59 AM GJU8302 v. 01/01/08 CLR CLR N
N N
N N
N SDQA Cat "C" UT-11-143 (Page 1)
UT-1 1-143 (Page 2)
McGuire 2 6/712011 9:29:17 AM Page 7 of 12
EOC 20 Report Results Insp Geo Insp Insp Summary No M2.R1.11.1564 Component ID 2NV2FW179-31 System Date NV 02/08/11 Status Limited CLR Y
Ref RFR Comment N
N UT-11-145 (Page 1)
Limitation due to reducer configuration NV 02/08/11 CLR NV 02/08/11 CLR NV 02/08/11 CLR Y
N N
UT-1 1-145 (Page 2)
Limitation due to reducer configuration Y
N N
UT-11-145 (Page 3)
Limitation due to reducer configuration Y
N N
UT-1 1-145 (Page 4)
Limitation due to reducer configuration M2IR1.11.1593 M2.R1.11.1595 2NV2FW183-29 NV 03/02/11 REC Y
N N
RT-11-04 Indications are acceptable: Film artifacts, convexity, and root edge. Linear indications outside Section XI exam area in adjacent weld 2NV2FW183-28 see PIP M-11-1846.
N N
N UT-11-157 (Page 1) 2NV2FW216-57 NV 03/01/11 CLR M2.R1.11.1596 2NV2FW216-53 NV 03/01/11 CLR NV 03/01/11 CLR NV 03/16/11 CLR NV 03/16/11 CLR NV 03/16/11 CLR NV 03/16/11 CLR N
N N
UT-11-157 (Page 2)
N N
N UT-11-157 (Page 3)
N N
N UT-11-168 (Page 1)
N Y
N UT-1 1-168 (Page 2)
Indication intermitten geometry N
N N
UT-11-168 (Page 3)
N N
N UT-11-168 (Page 4)
Printed 6/7/2011 9ý29:59 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 8 of 12
EOC 20 Report Results Insp Insp Insp Geo System Date Status Limited Ref RFR Summary No M2.R1.11.1596 Component ID 2NV2FW216-53 Comment NV 03/16/11 CLR N
N N
UT-11-168 (Page 5)
M2.R1.11.1597 2NV2FW216-52 NV 03/01/11 CLR NV 03/01/11 CLR N
N N
UT-11-155 (Page 1)
N Y
N IUT-11-155 (Page 2)
Indication 360 deg. intermittent geometry at lower amplitudes seen from S1 (downstream side)
M2.R1.16.0011 2NV2FW33-23 NV 02/08/11 CLR NV 02/08/11 CLR N
N N
UT-11-144 (Page 1)
N N
N UT-1 1-144 (Page 2)
NV 02/08/11 M2.R1.16.0020 2NV2FW179-31 CLR NV 02/08/11 CLR NV 02/08/11 CLR NV 02/08/11 CLR Y
N N
UT-11-146 (Page 1)
Limitation due to reducer configuration Y
N N
UT-11-146 (Page 2)
Limitation due to reducer configuration Y
N N
UT-1 1-146 (Page 3)
Limitation due to reducer configuration Y
N N
UT-1 1-146 (Page 4)
Limitation due to reducer configuration M2.Rl.16.0022 2NV2FW54-18 NV 03/04/11 CLR NV 03/04/11 CLR Y
N N
UT-11-160 (Page 1)
Tee is a forged fitting configuration causing limitation Y
N N
UT-11-160 (Page 2)
Tee is a forged fitting configuration causing limitation SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Printed 6/7/2011 9:29:59 AM GJU8302 v. 01/01/08 Page9 of12
EOC 20 Report Results Summary No M2.R1.16.0022 Component ID 2NV2FW54-18 Insp Insp I
System Date Status Lin NV 03/04/11 CLR NV 03/04/11 CLR NV 03/04/11 CLR r1sp Geo nited Ref RFR Comment Y
N N
UT-11-160 (Page 3)
Tee is a forged fitting configuration causing limitation Y
N N
UT-11-160 (Page 4)
Tee is a forged fitting configuration causing limitation Y
N N
UT-1 1-160 (Page 5)
Tee is a forged fitting configuration causing limitation M2.R1.16.0023 M2.R1.16.0024 2NV2FW116-21 NV NV NV NV NV NV 02/08/11 02/08/11 02/08/11 02/08/11 03/01/11 03/01/11 CLR CLR CLR CLR CLR CLA N
N N
N N
N N
N N
N N
N N
N UT-11-142 (Page 1)
UT-11-142 (Page 2)
UT-11-142 (Page 3)
UT-1 1-142 (Page 4) 2NV2FW216-57 N
N N
N UT-1l1-158 (Page 1)
UT-1l1-158 (Page 2)
M2.R1.16.0025 2NV2FW216-53 NV 03/01/11 CLR NV 03/16/11 CLR NV 03/16/11 CLR
- N N
N UT-11-158 (Page 3)
N N
N UT-11-169 (Page 1)
N Y
N UT-11-169 (Page 2)
Indication 360 deg. intermitent geometry N
UT-1 1-169 (Page 3)
N UT-11-169 (Page 4)
NV NV 03/16/11 03/16/11 CLR CLR N
N N
N Printed 6/7/2011 9:30:00 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 10 of 12
EOC 20 Report Results Insp Geo Insp Insp Summary No M2.R1.16.0025 M2.R1.16.0026 Component ID 2NV2FW216-53 2NV2FW216-52 System Date NV 03/16/11 Status Limited Ref RFR Comment CLR CLR CLR N
N N
UT-1 1-169 (Page 5)
NV NV 03/01/11 03/01/11 N
N N
Y N
N UT-11-156 (Page 1)
UT-1l1-156 (Page 2)
Indication 360 deg. intermittent geometry at lower amplitudes seen from S1 (downstream side)
M2.R1.16.0032 2NV2FW27-2 NV NV NV NV 03/04/11 03/04/11 03/04/11 03/04/11 CLR CLR CLR CLR N
- N N
N N
N N
N N
N N
N UT-11-162 (Page 1)
UT-11-162 (Page 2)
UT-1 1-162 (Page 3)
UT-1 1-162 (Page 4)
M2.Ri.16.0033 M2.R1.16.0034 2NV2FW115-5 NV NV NV NV NV NV NV NV 03/04/11 03/04/11 03/04/11 03/04/11 03/04/11 03/04/11 03/04/11 03/04/11 CLR CLR CLR CLR CLR CLR CLR CLR N
N N
N N
N N
N UT-11-163 (Page 1)
UT-11-163 (Page 2)
UT-11-163 (Page 3)
UT-1 1-163 (Page 4)
UT-11-164 (Page 1)
UT-1 1-164 (Page 2)
UT-11-164 (Page 3)
UT-11-164 (Page 4) 2NV2FW115-4 Printed 6/7/2011 9:30:00 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 11 of 12
Summary No M2.R1.16.0038 Component ID 2NV2FW183-29 Insp System Date NV 03/02/11 Insp Status REC EOC 20 Report Results Insp Geo Limited Ref RFR Comment Y
N N
RT-11-04 Indications are acceptable: Film artifacts, convexity, and root edge. Linear indication outside section Xl exam area in adjacent weld 2NV2FW1 83-28 see PIP M-11-1846.
NV 03/02/11 REC M2.R1.16.0039 2NV2FW183-4 N
N N
RT-n/a Indications acceptable: Film artifacts and root edge.
Printed 6/7/2011 9:30:00 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/7/2011 9:29:17 AM Page 12 of 12
5.0 Owner's Report for Repair / Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.
No item was determined to have had work performed outside this report period.
The NIS-2 forms included in this section were completed for work performed during this report period. The individual work request documents and manufacturers' data reports are on file at McGuire Nuclear Station.
5.1 Class 1 and 2 Preservice Examinations As required by the applicable code, Preservice Inspection (PSI)
Examinations were performed on ISI Class 1 and 2 items during this report period. All Class 1 and 2 PSI examination data shown in Attachment A is on file in the McGuire Nuclear Station QA Vault. Also included in this listing are the Class 3 PSI Examinations performed during this report period.
See Attachment A listing for Repair and Replacements for McGuire EOC 20.
EOC 20 Refueling Outage Report McGuire Unit 2 Section 5 Page 1 of 1 Revision 0 June 7, 2011
592075 592077 592077 592077 1840801 1841062 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1850786 1864184 1864184 1865842 1865842 1865844 1883394 1892972 1897283 1897290 1900003 Task 13 3
15 24 2
3 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 19 39 16 26 16 1
3 11 7
4 Class B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
Description of work Cut out and replaced valve 2BB6 Replaced pivot pin in rear bracket on hanger 2MCR-BB-4520 Cut out and replaced valve 2BB8 Replaced bolting material in pipe clamp on hanger 2MCR-BB-4519 Replaced soft seat disc in valve 2VI149 Replaced bolting material at valve 2VB50 Modified hanger 2MCA-FW-5009 per MGMM15247 Deleted hanger 2MCA-FW-5185 Deleted hanger 2MCA-ND-5483 Deleted hanger 2MCA-ND-5487 Replaced gap support with snubber on hanger 2MCA-FW-5184 Replaced gap support with snubber on hanger 2MCA-FW-5103 Replaced gap support with snubber on hanger 2MCA-FW-5181 Replaced gap support with snubber on hanger 2MCA-ND-5204 Replaced gap support with snubber on hanger 2MCA-ND-5280 Replaced gap support with snubber on hanger 2MCA-ND-5306 Replaced gap support with snubber on hanger 2MCA-ND-5311 Replaced gap support with snubber on hanger 2MCA-ND-5405 Replaced two gap supports with two snubbers on hanger 2MCA-ND-5461 Replaced gap support with snubber on hanger 2MCA-ND-5480 Replaced gap support with snubber on hanger 2MCA-ND-5482 Replaced gap support with snubber on hanger 2MCA-ND-5484 Replaced gap support with snubber on hanger 2MCA-ND-5485 Modified hanger 2MCA-RN-3215 per EC99741 Modified hanger 2MCA-RN-3215 per EC99741 Installed hanger 2MCR-RV-4173 per EC99747 Deleted hanger 2MCR-RV-4112 per EC99747 Modified item# 9 on hanger 2MCA-RV-511 per EC99747 Replaced disc in valve 2NV1047 Installed 4 item# 8s (1/2" x 3 1/2" x 6" plates) on hanger 2MCR-NS-4767 per EC101538 Replaced bolting material in flange 2NVFE5300 Replaced bolting material in flange 2NVFE5330 Replaced valve 2NV155 Attachment A Page I of 2
1900647 5
B Replaced relief valve 2NV229 Page 2 of 2 1907056 14 B
Replaced item# 7 (2 x 2 tube steel) on hanger 2MCA-NV-5050 per EC104199 1907056 2
B Replaced valve 2NV494 and piping per EC104199 1922371 1
B Replaced snubber on hanger 2MCA-SM-20 1922374 1
B Replaced snubber on hanger 2MCA-CA-60 1923830 2
B Replaced #4 rear valve and #5 cone valve in snubber for 2D Steam Generator 1923837 19 A
Replaced bolting materialon hangers 2MCR-NV-4379, 4380, and 4381 per EC105482 1923857 28 B
Replaced pivit pin on hanger 2MCA-NV-6523 1923857 45 A
Replaced snubber on hanger 2MCR-NC-4000 1923857 49 B
Replaced load pin in hanger 2MCR-NI-4589 1923857 62 B
Replaced snubber on hanger 2MCA-BB-5218 1923857 68 B
Replaced snubber on hanger 2MCR-S-VS-150-01-l 1923857 69 B
Replaced snubber on hanger 2MCR-NI-4918 1923857 75 B
Replaced snubber on hanger 2MCR-NV-4483 1923857 76 B
Replaced snubber on hanger 2MCR-ND-6326 1924239 4
A Replaced valve 2NC1 1925900 B
Installed items 8, 9, and 10 on hanger 2MCR-NS-4516 per EC101538 1927185 2
B Replaced disc and yoke on valve 2WL1302 1929198 6
B Replaced bolting material in pipe clamp on hanger 2MCR-NV-5192 1930670 89 B
Replaced snubber on hanger 2MCA-NV-5405 1932306 2
B Replaced disc in valve 2NV248 1933815 7
A Replaced disc and bonnet nuts on valve 2NI71 1972897 2
B Made weld repair on weld NV2FW183-28 1973388 5
B Welds NV2FW293-12, 38, and 39 were cut out and remade 1974289 2
A Replaced bolting material in flange down stream of valve 2NV180
I. Owner
- 2. Plant Duke-Energy Carolinas, LL 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO.
gPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
--- Date 4/3/2011 Charlotte, NC, 282.01 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 592075-13
- 3. Work Performed by Work Order # (or Repair/Replacement Organization P.O No.lob No., etc.)
Type Code Symbol Stamp:
N/A Authnrizatinn Nn : N/A 526 South Church Street, Charlotte, N.C._2.8_20.!.:.1..0_06....-......
Address Expiration Date:
N/A
- 4. Identification of System BB - Steam Generator Blowdown Recycle
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition withthe_.1_999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2BB6 Borg Warner 9081 90 N/A 1976 Removed Yes 2BB6 Flowserve 02BPK 2503 N/A 2009 Installed Yes
- 7. Description of Work Replaced Component/Part/Appurtenance Additional Description valve 2BB6 was cut out and replaced
- 8. Tests Conducted:
Pneumatic -
Nominal Operation Pressure F Description (Optional): test performed per procedure M.P/O/A/7650/076.
Exempt F Other r-Pressure 910 PSI Test Temp. 53.9 IF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY
" As Required by the Provisions of the ASME Code Section X1
- 9. Remarks.(Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
2 in. (nomiCnal)
Weld Isometric Drawing No(s).:
MCFI-2BB60 & 62 System Class: ASME Class_2 Flow Diagram No(s).:
MCFD-2580-Ol.00 Support/Restraint'Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCM 1205.00-0381 001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date IN/A Signed FL Grass, Quality Assurance Technical Specialist Date April 3 20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
- North Carolina nA -
,.Hartford Steam Boiler Inspection and Insurance Company
ý4ý
..Connecticut have inspected the components described in this Owner's Report during the period k- /b to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither th nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspectio JF Swan
]
/!".-"
Commissions NC1524, N-1 F) A tp. r)
Inspector's Signature
-V National Board, State, Province, and Endorsements 2o_-R Dt~te.
20))
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*
As Required by the Provisions of the ASME Code,Section III, Division 1 2
Pg. 1 of
- 1. Manufactured and certified by Flowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 Itame and address of N Certificate Holder)
- 2. Manufactured for Duke Energy PO Box 37925 Charlotte, NC 28237 Inmanm and address of Purchaser)
- 3. Location of installation McGuire Site 13225 Hagers Ferry (HWY 73) Huntersville, NC 28078-8985 ename and addr*ss)
- 4. Model No., Series No., or Type 1500' Gate Valve Drawing 74450 Rev.
C CRN N/A
- 5. ASME Code,Section III, Division 1:
1971 Summer 1973 2
N/A (edition)
(addenda date)
(class) lCode Case no.)
- 6. Pump or valve Valve Nominal inlet size 2
Outlet size 2
(in.)
(in.)
- 7. Material:
(a) valve Body SA182-F316 Bonnet SA182-F316 Disk SA351-UO' Bolting N/A (b) pump Casing Cover Bolting la)
Cert.
Holder's Serial No.
02BPK/
03BPK,"
- (bW Nat'l Board No.
2503
/
2504 (c)
Body/Casing Serial No.
A2-76//
A2-77 (d)
Bonnet/Cover Serial No.
.18427-1-1 38427-1-2 (e)
Disk Serial No.
N9519-6 N9519-7
- Supplemental information in the form of lists, siketches. or drawings may be used provided (41 size is 81/% x 11, (2) information in items 1 through 4 on this Data is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the lop of this form.
I'll
FORM NPV-1 (Back -
Pg. 2 of
)
S02BPK /ANDO 03BPK' Certificate Holder's Serial No.
- 8. Design conditions 1200 pso 567 tF or valve pressure class 1500 (lcrsa~areI ttemptratui el
- 9. Cold working pressure 3600 psi at 100T 5400 3960
- 10. Hydrostatic lest psi. Disk differential test pressure psi
- 11. Remarks: S.0- 53881 DRAIN PIPE-MATI: SA312-304, HEAT: 801951 CERTIFICATION OF DESIGN Design Specification certified by R.E.Miller RE. State SC Reg. no. 4237 Design Report certified by N/A PE. State N/A Reg. no.
N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report ate correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.
N Certificate of Authorization No.
N-1562 Expires 11-26-09 Date
',_-9*
Name Flowserve Corporation Signed IN Ce~sficele I-QIderlta.,
ed pfcscfnLaloe)
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB CT of Hartford, CT have inspected the pump, or valve, described in this Data Report on
,and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve.
in accordance with the ASME Code,Section III, Division 1.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or properly damage or a loss of any kind arising from or connected with this inspection.
Date ol /
Signed Commissions A)B /7o,9/t/(
e-L/5Y7 I
Auflthorizad Nuclear Insp.tq lNatl. 1d. fincl. endorsements end state or pov. and no.)
FORM NIS-2 OWNER'S REPORT FO,
-PAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 4/12/2011
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL 526.Sou.th..Chu-urch Street., Charlotte,.NC, 28201 Address McGuire Nuclear Station Narne Sheet 1
of 2 Unit 2 1.2700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 2820 1-1006 Address 592077-03 592077-03 Work Order # (or Repair/Replacement Organization P.O. No., lob No, etc Type Code Symbol Stamp: N/A Authorization No.:
N/A N/A Expiration Date:
- 4. Identification of System BB - Steam Generator Blowdown Recycle
- 5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Editioh with the_19.99.and 2000 A dde.nda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Nane of alttfacturcr Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-BB-4520 Duke Energy N/A N/A N/A N/A Installed No
- 7. Description of Work Additional Description Replaced CopretprtApreac replaced pivot pin in rear bracket on hangrer 2MCR-BB-4520.
- 8. Tests Conducted:
Hydrostatic F Pneumatic F Nominal Operation Pressure F Exempt Fý Other F-Pressure PSI Test Temp. _
°F Description (Optional):
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).: MCFI-2BB60 & 63 Sheet 2 of 2 System Class:
ASME.Class2 Flow Diagram No(s).:
MCFD-2580-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCR-BB-4520 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requiremnents of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
,Q:
,*,A.
Date April 12 20.11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by.Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Zto
_* /2-.- //Z, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither t e Inspector nor his employer shall be liable in any manner for any persdnal injury or property damage or a loss of any kind arising fro or connected with this inspectio JF Swan O
2.21v0-tj-Commissions NC1524, N-I Dat/
Inspector's Signature National Board, State, Province, and Endorsements 20 //
Dat 20 /1
- 1. Owner
- 2. Plant Duke. Energy Carolinas, LL 526_South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOK JIPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 4/3/2011 Charlott.e.,.NC, 2820-1...
Sheet I
of 2 Station Name 12700 Hagers Ferry Road, Huntersville, NC 28.078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC.
Name 526 South Church Street, Charlotte, NC.2820!.-1006 Address Unit 2 592077-15 Work Order # (or Repair/Replacement Organization P.O. No, Job No., etc
,, r-,*, 1
.,Q.11 IQ...
N/A rp,*
Authorization No.:
Expiration Date:
- 4. Identification of System BB - Steam Generator Blowdown Recycle
- 5. (a) Applicable Construction Code ASME Ill 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacernent Activity 1998 Edition with.the 19.99 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Serial No.
Board No.
Identification Built Installed (Yes or No)
Name of Manut'acturerSeilNBorNodetfctoBut nald(YsrNo 2BB8 Borg Warner 9087 95 N/A 1976 Removed Yes 2BB8 Flowserve 04BPK 2501
'N/A 2009 Installed Yes
- 7. Description of Work Additional Description Replaced Componen.t/Part/Apipiureenance valve 2BB8 was cut out and replaced
- 8. Tests Conducted:
Pneumatic r Nominal Operation Pressure Description (Optional):
test performed. per procedure MP/0/A/7650/076.
Exempt r.
Other Fl-Pressure 910 PSI Test Temp. 53.9 OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2BB60 & 63 Sheet 2 of 2 Systern Class:
ASMEClass_2 Flow Diagram No(s).:
MCFD-2580-01.00 Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
- MCM 1205.00-0381 001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date April 3
,20 11 Owner or Owner's Designee, Title CERTI FICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by :Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
.*2 7-to
/Z'
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from i connected with this inspection.
- JF Swan Commissions NC1524, N-i Inspector's Signature National Board, State, Province, and Endorsements LI
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*
As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of__
- 1. Manufactured and certified by. Flowserve Corporation, 1900 South Saunders St. Raleigh. NC 27603 Iname and address of N Ceitilicate Holdai)
- 2. Manufactured for Duke Energy PO Box 37925 Charlotte, NC 28237 Insme and address oi Puidrascil
- 3. Location of installation McGuire Site 13225 Hagers Ferry (HWY 73) Huntersviile, NC 28078-8985 Inama and address)
- 4. Model No., Series No., or Type 1500# Gate Valve Drawing 74450 Rev.
C CRN N/A
- 5. ASME Code, Section I11, Division 1:
1971 Summer 1973 2
N/A (ediSon)
(addenda date)
Wclass) lCode Case no.)
- 6. Pump or valve Valve Nominal inlet size 2
Outlet size 2
jin.)
tin.)
.7. Material:
(a) valve Body SA182-F316 Bonnet SA182-F316 Disk SA351-8M Bolting N/A (b) pump Casing Cover Bolting (a)
Cen.
Holder's Serial No.
04BPK OSBPK Wb Nat'l Board No.
2501 2502 (c)
Body/Casing Serial No.
A2-78 A2-79 (d)
BonneVCover Serial No.
let Disk Serial No.
38427-1-3 N9519-8~
18427-114 N9519-9 y I supplemental information in the form of lists, sketches, or dfawings may be used provided 11) size is 8112 x 11. (2) information in items I through 4 on this Data Report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
rn~so(%/7
FORM NPV-1 (Back -
Pg. 2 of 02BPK THRU OSBPK Certificate Holder's Serial No. 02_PK___________
- 8. Design conditions 1200 psi 567 t or valve pressure class 1500 lprfessul tli pecralne)
- 9. Cold working pressure 3600 psi at 100'F s40Oo 3960
- 10. Hydrostatic test psi.
Disk difleiential test pressure psi
- 11. Remarks: S.O. 53881 f
DRAIN PIPE-MATL: SA312-304. HEAT; 801951 CERTIFICATION OF DESIGN Design Specification certilied by R.E.Miller RE. State SC Reg. no.4237 Design Report certified by N/A RE. State N/A Reg. no.
N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.
N Certificate of Authorization No.
N-1562 Expires 11-26-09 Date Name Sge IN Certie c Holdel)
"oor in Seientgdne CERTIFICATE OF INSPECTION I, the undersigned, holding a vaiid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB CT of Hartford, CT have inspected the pump, or valve, described in this Data Report on 9
2A
, and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with.the ASME Code,Section III, Division 1.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Date l
Commissions (AU:,J ze uclteo Irnspacror tNarl. Bd. (incl. endoisenen it3l and state Of prOi. and no.l p
63ro/'7:
- 1. Owner
- 2. Plant Duke Energy Carolinas,.LL 526.So.uthChurch Street,.
Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT F.
- EPAIP/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI C
Date 4/12/2011 Charlotte, NC_, 28201..
Sheet 1
of 2 Station Name Unit 2 12700 Hagers Ferry Road, _Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 592077-24 Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street,..Ch.arlotte,._NC 28201-1006 N/A Address Expiration Date:
- 4. Identification of System BB - Steam Generator Blowdown Recycle
- 5. (a) Applicable Construction Code ASME I11 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity.19.98 Edition with_the._199.9..and 2.000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of' Manufacturer National Other Year Removed, or Stamped ComponentIntle YsoN)
Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-BB-4519 Duke Energy N/A N/A N/A N/A in!Pstalled No
- 7. Description of Work Re Additional Description re
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Part/Apputecnance
~placed bolting material in pipe clamp on hanger 2MCR-BB-45 19.
Pneumatic F-Nominal Operation Pressure iF Exempt F Other F Pressure
-PSI Test Temp. _
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2BB60 & 63 Sheet 2 of 2 System Class:
ASME.Class 2 Flow Diagram No(s).:
.MCFD-2580-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCR-BB-4519 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date ýApril 12
,20W.l Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
-'2-7-62
/(
to
/-7./'Z.2,.--,
., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Insp tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.
JF Swan'
=
.*Commissions NC 1524, N-I Inspector's Signature ational Board, State, Province, and Endorsements L
- /Z-
,20/_/_
I. Owner
- 2. Plant Duk.e Energy Carolinas, LL 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT F REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC Date 4/3/2011 Charlotte, NC, 28201 Sheet I
of 2 Station
- 3. Work Performed by Name 12700 Hagers.Ferry Road, H.untersviIlle,.N.C 28078 Address Duke Energy Carolinas, LLC.....
Name 526 South Church Street,.Ch.arlotte, NC 28_20.1-1006 Address Unit 2 1840801-02 Work Order # (or Repair/Replacement Organization P 0. No., Job No., etc.)
Type Code Symbol Stamp:
N/A Authorization *No.: N/A Expiration Date:
N/A
- 4. Identification of System VI - Instrument Air
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with..the.19.99 an-d_2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Mantfacttrer Serial No.
Board No..
Identification Built Installed.
(Yes or No) 2V 1149 Kerotest S20-15 N/A N/A 1973 In.s*talled Yes
- 7. Description of Work Re Additional Description re
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Part/Appurtenance placed soft seat disc in valve 2V1149.
Pneumatic F Nominal Operation Pressure Exempt F Other F Pressure PSI Test Temp. _
°F
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASNIE Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2VI29 Sheet 2 of 2 SystemDClass:
ASMEClass2 Flow Diagram No(s).:
MCI Support/Restraint Sketch/Drawing No(s).:
N/A FD-2605-Ol.02 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2V1-250 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section.XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date April 3
,20 il Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
,,_ t.- /
Z to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither t Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspectio JF Swan Commissions NC1524, N-I National Board, State, Province, and Endorsements DateU-20//
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT I REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the.-\\SME Code Section XI
'C Date 3/31/20 I1 Charlotte, NC, 28201 Sheet I
of 2 Station Unit 2 Name
- 3. Work Performed by 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 28201-1006 Address 1841062-03 Work Qrder # (or Repair/Replacement Organization P 0. No.. lob No, etc.)
Type Code Symbol Statnp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of Systern VB - Breathing Air
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI CodeCase(s) N/A
- 6. Identification of Components Corrected, ASME Code Namne of Matnufacturer National Other Year Removed, or Stamped Component ofMaUfacturer Serial No.
Board No.
IdenTification Built Installed (Yes or No) 2VB50 Anderson Greenwood N 15025 26 N/A 1982 Installed Yes
- 7. Description of Work Replaced Component/Part/Appurtenance Additional Description replaced bolting material at valve 2VB50.
- 8. Tests Conducted:
Hydrostatic F Pneumatic F Nominal Operation Pressure [F Description (Optional):
test performed per procedure MP/0/A/7700/045.
Exempt F-Other r-Pressure PSI Test Temnp. _
IF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section X I
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
- 2) in. (nomninal)
Weld Isometric Drawing No(s).:
MCFI-2VB3 Sheet 2 of 2 System Class:
ASME Class 2 Flow Diagram No(s).:
MCFD-2605-03.Ol Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manutacturer'.s Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
.,,Date March,31
-. l Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Co-nnci
-c /
to h
?
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner'A Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any. kind arising from/ connected with this inspection.
JF Swan
=-
Commissions NC1524, N-I Dat C Inspector's Signature National Board, State, Province, and Endorsements
-)0_/a Dat 20/L
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FC
.ýEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC Date 3/22/2011 Charlotte, NC, 28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 28201-1006 Address 1850786-06 Work Order l9 (or Repair/Replacement Organization P.O. No.. lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System FW - Refueling Water
- 5. (a) Applicable Construction Code ASME I1l 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1.9.99 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Maltlttfcturer National Other Year Removed, or Stamped Component Nate of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-FW-5009 Duke Energy N/A N/A N/A N/A Installed No J
-~
4-4 4
1 4-
+
- 7. Description of Work Re:
Additional Description tn
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Part/Appurtenance odified hanger 2MCA-FW-5009 per MGMM 15247 Pneumatic r-Nominal Operation Pressure [-
Exempt.
Other r Pressure PSI Test Temp. _
°F
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
24 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class:
- Flow Diagram No(s).:
MCFD-257 1-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-FW-5009 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM 15247, MCSRD-2FW-350-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 22 201L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Q
/c/o to 2
2
//
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Ins tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or onnected with this inspection.
JF Swnom 7,,,.
.Commissions NC 1524, N-I SInspector's Signature National Board, State, Province, and Endorsements Dat e 0
20 /
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO.
.EPAIRJREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC Date 3/22/2011 Charlotte, NC, 28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC N*lve 526 South Church Street, Charlotte, NC 28201-1006 Address 1850786-07 Work Order # (or Repair/Replacernent Organization P 0) No., Job No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System FW - Refueling Water
.5. (a) Applicable Construction Code ASME Ill 19 71 Edition, Summer and Winter
- Addenda, N/A Code Case (b) Applicable Edition of Section X1 used for Repair/Replacement Activity 1998 Edition with the 1999 and 2.000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufaclurer National Other Year Removed, or Stamped Component Name of Manutitclurer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-FW-5185 Duke Power N/A N/A N/A N/A Removed No
- 7. Description of Work Additional Description
- 8. Tests Conducted:
Hydrostatic Description (Optional):
dther (Describe Below) deleted hanger 2MCA-FW-5 185 Pneumatic F-Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
12 in. (nominal)
Weld Isometric Drawing No(s).: N/A System Class: ASME Class.2 Flow Diagram No(s).:
MCFD-257 1 -01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-FW-5185 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM 15247, MCSRD-2FW-350-005 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality, Assurance Technical Specialist
/Date March 22
,20 11 Owner or Owner's Designee, Title CERTI FICATE OF INSERV ICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina *and employed by Hartford Steam Boiler Inspection and Insurance Company of
.Connecticut have inspected the components described in this Owner's Report during the period 2~
/
Z:
1 to
/
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o,, connected with this inspection JF Swan V 0,,,ý.
Commissions NC1524,N-I Date d Inspector's Signature 1/
National Board, State, Province, and Endorsements 20o//
Date 20 /1
FORM NIS-2 OWNER'S REPORT FL HEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
-Date 3/22/2011
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL 526 South Church Street, Charlotte, NC, 2820 1 Address McGuire Nuclear Station Name 12700 Hagers Ferry Road, Huntersville,.NC 28078 Address Sheet I
of 2 Unit 2 1850786 Work Order # (or Repair/Replacement Organization P.O. No., lob No., etc.)
- 3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC 2.820 1-.1006 Address N/A Expiration Date:
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME I11 19 71 Edition, Summer and Winter (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999_and 2000 Addenda.
Addenda, N/A Code Case (c) Applicable Section X1 Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Buiilt Installed (Yes or No) 2MCA-ND-5483 Duke Energy N/A N/A N/A N/A Removed No 4-F
+
4
+/-
- 4.
F t
-r i
+
F t
r
-r i
T
.1.
5 F
+
4
+
+/-
- 7. Description of Work Additional Description Other (Describe Below)
Deleted hanger 2MCA-ND-5483
- 8. Tests Conducted:
Hydrostatic F Pneumatic "-
Nominal Operation Pressure F Exempt F" Other F Pressure IPSI Test Temp. _
°F Description (Optional):
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
14 in. (nominal)
Weld Isometric Drawing No(s).: MCFI-2ND3 SystemFClass:
ASME CFass20 Flow Diagram No(s).:
MCFD-MvCFD-256 1-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5483 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM 15247, MCSRD-2FW-350-005 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 22
, 201L_
Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
.North Carolina and employed by Hartford Stearn Boiler Inspection and Insurance Company of have inspected the components described in this Owner's Report during the period Connecticut to 2-2-. - ii
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warrantvy expressed or implied, concerning the examinations and corrective rneasures described in this Owner's Report. Furthermore, neither t# Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from( connected with this inspectio JF Swan
,0 y,
Commissions NC1524, N-I Inspectors Signature D teý-2 -,
National Board, State, Province, and Endorsements 20//'
FORM NIS-2 OWNER'S REPORT F(
.ýEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 1. Owner Duke.Energy Carolinas, LLC Date 3/22/2011
- 2. Plant 526. South Church Street, Charlotte, NC, 28201 Address McGuire Nuclear Station Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Sheet I
of 2 Unit 2 1850786-09 Work Order I (or Repair/Replacement Organization P.O No., lob No, etc.)
- 3. Work Performed by Duke Energy Carolinas, LLC Naine Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
N/A N/A 526 South Church Street, Charlotte, NC 28201-1006 Address N/A
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME Il l 1971 Edition, Summer and Winter (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2.000 Addenda Addenda, N/A Code Case (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASIM E Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5487 Duke Energy N/A N/A N/A N/A Removed No
- 7. Description of Work Additional Description Other (Describe Below)
Deleted hanger 2MCA-ND-5487
- 8. Tests Conducted:
Hydrostatic F-Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Ternp.. _
Description (Optional):
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
14 in. (nominal.)
Weld Isometric Drawing No(s).:
MCFl-2ND3 System Class:
ASME Class.2 Flow Diagram No(s).:
MCFD-256 1 -0 1.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5487 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM 15247, MCSRD-2FW-350-005 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
-*Z,/,-_
Date March 22
,20jL Owner or Owner's Designee, Title D/
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina Connecticut and employed by, Hartford Steam Boiler Inspection and Insurance Company of have inspected the components described in this Owner's Report during the period
/
to 2-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore; neither the Ins ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o ed with this inspection.
JF Swan re Commissions NC 1524, N-I D t I[nspector's Signature Date 6-
-2 f
National Board, State, Province, and Endorsements 20./1 I
(
I. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FC
.EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI LC Date 3/21/2011 Charlotte, NC, 28201 Sheet I
of 2 rStation Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy.Carolinas, LLC Name 526 South. Church Street,_-Charlotte,. NC 28201-1006.
Address 1850786-10 Work Order # (or Repair/Replacement Organization P.O. No., Job No, etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System FW - Refueling Water
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-FW-5184 Duke Energy 38039 N/A N/A N/A Installed No
- 7. Description of Work Rep Additional Description Re
- 8. Tests Conducted:
Description (Optional):
)laced Component/Part/Appurtenance eplaced gap support with snubber on hanger 2MCA-FW-5 184 Pneumatic r-"
Nominal Operation Pressure r-Exempt F Other F Pressure PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X I
- 9. Remarks (Should Include the Follow ing aInformation, as Applicable):
Component Line Size:
12 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class:
ASME'Class 2 Flow Diagram No(s).:
MCFD-257 1-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-FW-5184 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM15247 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
./
Date 'March 21
,20 1I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and emplnvoyed b Hartford Steam Boiler Inspection and Insurance Company of
-'J Connecticut have inspected the components described in this Owner's Report during the period 2/7"//
/
to
_S-2 2--g(
,and state that to the best of my knowl6dge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.
JF Swan Commissions NC1524, N-1 II~~pcLI0I
~.J~~gI~a~uI~,r
/
IN~Ij~
014 U
- 44C Av~s UIUCIUICIC Dat 6 1 In p ct r s Si n tr2 _
- 1N4aLtIion oar l,
- tatel, rlUVl ce, anll nlUUrsernetsli
, 20__/
- 1. Owner 2, Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC Date 3/21/2011 Charlotte, NC, 28.201 Sheet I
of 2 Station Unit 2
- 3. Work Performed by Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC._28201-1006 Address 1850786-11 Work Order # (or Repair/Replacement Organization P.O. No.,.Job No., etc Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System FW - Refueling Water
- 5. (a) Applicable Construction Code ASME III 19 7_1 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X I used for Repair/Replacement Activity 1998. Edition with the_19_99.9_and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Cotmponentitsald (Yso o
Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-FW-5103 Duke Energy 38040 N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description Rt
- 8. Tests Conducted:
Description (Optional):
placed Component/Part/Appurtenance eplaced gap support with snubber on hanger 2MCA-FW-5 103 Pneumatic F Nominal Operation Pressure F Exempt P.
Other F Pressure
-PSI Test Temp. _
°F
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
18 in. (nominal)
System Class:
ASME Class 2 Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
MCFD-2563-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-FW-5103 Other Applicable Information (e.g., W.O. No., EC No.) if ndt included elsewhere on NIS-2 Form:
MGMM 15247 Sheet 2 of 2
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist "DateMarch 21 20_11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina aHartford Steam Boiler Inspection and Insurance Company Norh aroin
.and employed by _____________________________________of Connecticut have inspected the components described in this Owner's Report during the period 13 --/ / --/1 to 3 - 2. Z -l(e, and state that to the 'best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's eport. Furthermore, neither the I ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o onnected with this inspection.
JF Swan Commissions NC 1524, N-I I
/
Inspector's Signature National Board, State, Province, and Endorsements I
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526.South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO
.EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
-C Date 3/21/2011 Charlotte, NC, 28201.
Sheet 1
of 2 Station Unit 2
- 3. Work Performed by Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 28201-.1006 Address Work Order # (or Repair/Replacernent Organization P.O. No., lob No. etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A 1850786-12
- 4. Identification of System FW - Refueling Water
- 5. (a) Applicable Construction Code ASME III 19 7_1 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xf Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of' Manufacturer National Other Year Removed, or Stamped Component Serial No.
Board No.
dentification Bult Installed (Yes or No)
Name of39Ma8N//cturerS No 2MCA-FW-5 181
.Duke Energy 37958 N/A N/A N/A Installed No
- 7. Description of Work ReF Additional Description Re
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
laced Component/Part/Appurtenance eplaced gap support with snubber on hanger 2MCA-FW-5 181 Pneumatic F' Nominal Operation Pressure F Exempt F Other F-Pressure PSI Test Temp. _
IF
FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
24 in. (nominal)
Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).:
MCFD-2563-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-FW-5181 Sheet 2 of 2 System Class: ASMECass.2.
Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere oin NIS-2 Form:
MGMMI5247 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March21 50f11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
.North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Z
.3 2
-/
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither t Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspectio JF Swan Commissions NC 1524, N-I Inspector's Signature National Board, State, Province, and Endorsements Date
()
3 Z -
,210 Itl
FORM NIS-2 OWNER'S REPORT FO.
..EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 1. Owner
- 2. Plant Duke Energy Carolinas, LLC 526 South Church Street, Charlotte, NC, 28201 Address McGuire Nuclear Station Name 12700 Hagers Ferry Road, Huntersville,.NC 28078 Address Date 3/21/2011 Sheet I
of 2 Unit 2 1850786-13 Work Order 9 (or Repair/Replacement Organization P 0 No.,,Job No., etc.)
- 3. Work Performed by Du.k.e Energy Caro.linas, LLC Name Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
526 South Church Street, Charlott., NC 2820 1 --1006 Address
- 4. Identification of System ND - Residual Heat Removal
- 5. (a).Applicable Construction Code ASME III (b) Applicable Edition of Section X l used for Repair/Replacement Activity 1998 Ed (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Comn)onents 19 71 Edition, Summer and Winter
[ition with the 1999 and 2000 Addenda Addenda, N/A Code Case Corrected.
ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5204 Duke Energy 36142 N/A N/A N/A Installed No
- 7. Description of Work Replaced Component/Part/Appurtenance Additional Description R
- 8. Tests Conducted:
Description (Optional):
eplaced gap support with snubber on hanger 2MCA-ND-5204 Pneumatic F Nominal Operation Pressure F Exempt F Other I-Pressure PSI Test Temp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions ofthe ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
12 in. (nominal)
Weld Isometric Drawing No(s).:
N/A System Class:
ASME Class.2 Flow Diagram No(s).:
MCFD-2561-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5204 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM 15247 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A SignedFL Grass, Quality Assurance Technical Specialist
,Date.March 21
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period to 3
/(and state that to the best of my knowledge and.belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his ployer makes any warranty, expressed or implied, concerning the examinations and corrective.measures described in this Owner's eport. Furthermore, neither the Ins 'tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o nnected with this inspection.
Swan Commissions NC1524, N-I eNational Board. State, Province, and Endorsements
I. Owner
- 2. Plant Duke Energy Carolinas, LL 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT Ft AEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 3/21/2011 harlotte,.NC_28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 1850786-14 1850786-14
- 3. Work Performed by Work Order # (or Repair/Replacement Organization P.O No, Job No, etc Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC 28201-1006 N/A Address Expiration Date:
N/A
- 4. Identification of System ND - Residual Heat Removal
- 5.
(a) Applicable Construction Code ASME Il1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition W\\ith the..1999 and 2000 Addenda (c) Applicable Section XI Code Case(s).N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name ofManufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5280 Duke Energy 37464 N/A N/A N/A Installed No
- 7. Description of Work Rel Additional Description Rt
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Pa&Appurtgrance eplaced gap support with snubber on hanger 2MCA-ND-5280 Pneumatic --
Nominal Operation Pressure r-Exempt F Other F Pressure
.PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASNIE Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
12 in. (nominal)
System Class: ASMEClass_2 Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
MCFD-2561-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5280 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM15247 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE, I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
- MDate March 21 2011 Owner or Owner's Designee, Title
/
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
.North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
.Lf zZ-..."
to Is 2
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Fuermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from9 connected ith this inspection.
JF Swan Commissions NC1524, N-1 C
~n~'r~ctor's Signature Date,
2-,
20fL National Board, State, Province, and Endorsements
I. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South. Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FG-- AEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
£C Date 3/21/2011 Charlotte, NC, 28201 Sheet 1
of 2 Station Unit 2 Name
.12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 1850786-15
- 3. Work Performed by Work Order 9 (or Repair/Replacemnent Organization P.O. No.. Job No., etc Type Code Symbol Stamp:
N/A Authorization No.: N/A 4.
5.
6.
526 South Church Street, Ch.arlotte. N.C 28201 -. 1006 N/A Address Expiration Date:
Identification of System ND - Residual Heat Removal (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity.199 _Edition with the 1999 and 2000 Addenda._
(c) Applicable Section Xl Code Case(s) N/A Ide~ntificntion of Cnmnone~nts Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5306 Duke Energy
.37465 N/A N/A N/A Installed No
- 7. Description of Work Rep Additional Description Re
- 8. Tests Conducted:
Hydrostatic r Description (Optional):
placed Component/.Part/Appurtenance tplaced gap support with snubber on hanger 2MCA-ND-5306 Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
12 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class: ASMEClasss 2 Flow Diagram No(s).:
MCFD-2561-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5306 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM15247 Applicable Manufacturer's Data Reports to be attached
- CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date :March 21
,2'IlI Owner or Owner's Designee, Title
,20 CERTI FICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
.3*.-*.'to S
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthennore, neithe ie Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this ins t
JF Swan Commissions NC1524,N-I Inspector's Signature
/
National Board, State, Province, and Endorsements
/
I
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI
.52.6__South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO.
.EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC Date 3/21/20 1'l Charlotte,NNC,2820_..
Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 1850786-16 Work Order # (or Repair/Replacement Organization P 0. No.,.lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC 2§1201-1.I006 N/A Address Expiration Date:
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME III 19 7_1 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998 Edition with the.1.9.9.*.and _2.000_Ad~dend.a (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5311 Duke Energy 37466 N/A N/A N/A Installed No 4
4 4
5
+
4 4
4 5
+
5 4
4 1
5
+/-
- 7. Description of Work Rel Additional Description R
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Comp onnt/Par/Appiurtenance eplaced gap support with snubber on hanger 2MCA-ND-531 I Pneumatic F' Nominal Operation Pressure F Exempt F7 Other --
Pressure PSI Test Temp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
12 Weld Isometric Drawing No(s).:
N/A in. (nominal)
System Class:
ASM.E Class.2 Flow Diagram No(s).:
MCFD-256 101.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5311 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM15247 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 21
,2011 Owner or Owner's Designee, Title D
2 11 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
,to
-Z. 2 -/
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither th Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from 1connected with, this inspection.
JF Swan_*
2 7A._ -.
^
Commissions.NC1524, N-I O
Inspector's Signature ooý National Board, State, Province, and Endorsements Date-20-/
FORM NIS-2 OWNER'S REPORT FO. _,*EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 1. Owner
- 2. Plant Duke Energy Carolinas, LLC 526 South Church Street, Charlotte,. NC, 28201.
Address McGuire Nuclear Station Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Date 3/21/2011 Sheet I
of 2 Unit 2 1850786-17 Work Order 9 (or Repair/Replacement Organization P 0. No., Job No., etc.)
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 2820 1-1006 Address Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME III (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components 19 71 Edition, Summer and Winter lition with the-1999 and 200.0 Addenda Addenda, N/A Code Case Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5405 Duke Energy 37467 N/A N/A N/A Installed No
- 7. Description of Work Additional Description Replaced Component/Part/Appurtenance Replaced gap support with sntibber on hanger 2MCA-ND-5405
- 8. Tests Conducted:
Description (Optional):
Pneumatic F]-
Nominal Operation Pressure F Exempt WF. Other F Pressure PSI Test Temp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of (he ASME Code Section X1
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
14
- in. (nominal)
Weld Isometric Drawing No(s).: N/A Sheet 2 of 2 System Class:
ASME Class_2 Flow Diagram No(s).:
MCFD-2561-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5405 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM 15247 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 21
,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
.Connecticut have inspected the components described in this Owner's Report during the period 54 /--
to 12.2-/, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' eport. Furthermore, neither the I ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from onnected with this inspection.
417 Swan tCommissions NC1524, N-I
-nspector's Signature
/
F National Board, State, Province, and Endorsements Date C'j -S, - ?,"2--
, 20_A/
- 1. Owner
- 2. Plant DukeEn.ergy Carolinas, LL
.526 South Church.Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT.
A REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI Q
-Date 3/21/2011 Charlotte,..NC,.28201 Sheet 1
of 2 Station Unit 2 Name 12700 Hagers Ferry Road,.Iuntersville, NC 28078 Address Duke EnergyCarolinas, LLC Narne 1850786-18 Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
- 3. Work Performed by Type Code Symbol Stamp:
N/A Authorization No : N/A 526 South Church Street, C.harlotteNC.?820-.0.6 1N/A Address Expiration Date:
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity _1998.Ed.i.tion with.th-e 1_999.and.2000_Add-en-da__
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manmfactttrer National Other Year Removed, or Stamped Component Installed (Yes or No)
Name oftManufacturer Serial No.
Board No.
ldeniication Bil(
2MCA-ND-5461 Duke Energy 37640 N/A N/A N/A Installed No 2MCA-ND-5461 Duke Energy 37468 N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description R
- 8. Tests Conducted:
Hydrostatic 7 Description (Optional):
placed Comip onent/Part/Appurtenance eplaced two gap supports with two snubbers on hanger 2MCA-ND-5461 Pneumatic [-
Nominal Operation Pressure F Exempt F.
Other [7 Pressure PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section X I
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
14 in. (nominal)
System Class:
ASME Class 2 Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
IVICFD-2561-Ol.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5461 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM 15247 Applicable Manufacturer's Data Reports'to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
-.--Date March 21
,20 li Owner or Owners Designee, Title Iw e orO nrsDsIne il CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina
,, Hartford Steam Boiler Inspection and Insurance Company Connecticut have inspectd te cy U0 have inspected the components described in this Owner's Report during tihe period m
- /d7-a to L-3 2
//
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fron* or connected with this inspec/n.
JF Swan V
/.Commissions NC1524, N-1 Date(I Inspector's Signature National Board, State, Province, and Endorsements 20 //
Dates 20J/
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI
.5.2. South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO..,EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC Date 3/21/2011 Charlotte, NC, 28201 Sheet 1
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 1850786-19 1850786-19
- 3. Work Performed by Work Order 9 (or Repair/Replacement Organization P.O No., Job No, etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 4.
5.
52.6 South Church Street, Charlotte, NC 2_8201 -1006 Dt:./
Address Expiration Date:
N/A Identification of System ND - Residual Heat Removal (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity.1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A Identification of Comn onents 6.
Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Matiracturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5480 Duke Energy 37469 N/A N/A N/A Installed No
- 7. Description of Work Rep Additional Description Re
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Part/Appurtenance eplaced gap support with snubber on hanger 2MCA-ND-5480 Pneumatic F-Nominal Operation Pressure F Exempt F.
Other F Pressure PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
14 in. (nominal)
System Class: ASMjE.CIass.2 Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
MCFD-256l-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5480 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM15247 Sheet 2 of 2 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 21
,0 1
Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut -
have inspected the components described in this Owner's Report during the period,12
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner'Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o onnected with this inspection.
F Swan Commissions NC1524, N-I U
e Inspector's Signature Date National Board, State, Province, and Endorsements 20//
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South _Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO.
-EPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 3/21/2011 Charlotte, NC, 2820!...
Sheet I
of 2 Station Unit 2 Name 12700 Hagers.Ferry Road, Huntersville _NC(.2807.8_
Address
- 3. Work Performed by DukeeEnergyCarolinas, LLC Name 526 South Church Street, Charlotte, NC 28201-100_6 Address 1850786-20 Work Order # (or Repair/Replacement Organization P.O. No., Job No, etc Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME Il1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with-the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5482 Duke Energy 37545 N/A N/A N/A Installed No
- 7. Description of Work Rep Additional Description Re
- 8. Tests Conducted:
Hydrostatic r Description (Optional):
ilaced Component/Part/Appurtenance placed gap support with snubber on hanger 2MCA-ND-5482 Pneumatic F-Nominal Operation Pressure Exempt f Other F Pressure PSI Test Ternp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR!REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
14 Weld Isometric Drawing No(s).:
N/A in. (nominal)
System Class:
ASME Class 2 Flow Diagram No(s).:
MCFD-2561-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5482 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM15247 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the.report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 21
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
'North Carolina H,,*
Hartford Steam Boiler Inspection and Insurance-Company r
.Connecticut have inspected the components described in this Owner's Report during the period
-Z..
3z.2.i*
to.3 -.
., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.
JF Swan (I.,,-t.'/
t Commissions NC1524, N-I Dat(2 Inspector's Signature -'-'
National Board, State, Province, and Endorsernents
'; 22 20-L
- 1. Owner
- 2. Plant
.Duk.e. Energy Carolinas, LL 526.South.Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO.
.EPAIR1REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 3/21/2011 Cha.rlotte,. NC,.28201..
Sheet I
of 2 Station Unit 2 Name 12700 Hagers FerryRoad,.Huntersvl lle, NC 28078 Address Duke Energy Carolinas, LLC Name 1850786-21 Work Order # (or Repair/Replacement Organization P 0. No,.Job No., etc )
- 3. Work Performed by N/A Type Code Symbol Starnp:
Authorization No.:
526 South Church Street, Charlotte, NC 2.8201-1006 N/A Address Expiration Date:
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1.9.98 Edition with t.he_1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name ofManufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5484 Duke Energy 37470 N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description Rt
- 8. Tests Conducted:
Hydrostatic r Description (Optional):
placed Component/Part/Appurtenance eplaced gap support with snubber on hanger 2MCA-ND-5484 Pneumatic F Nominal Operation Pressure r Exempt Wl Other F Pressure
.PSI Test Temp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
14 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
MCFD-2561-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5484 Sheet 2 of-2 System Class:
ASME Class 2 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM15247 r
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 21
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Noh CHartford Steam Boiler Inspection and Insurance Company North Carolina arid employed by oof
'Connecticut have inspected the components described in this Owner's Report during the period 7"to-
-//,
40,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector norhis employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ownerj# Report. Furthermore, neither thee spector nor his employer shall be liable in any manner for any personal injury or property' damage or a loss of any kind arising from connected with this inspection.
JF Swan Commissions NC1524, N-I Date Inspector's Signature National Board, State, Province, and Endorsements 1
20 //
Date (1
2-22~
201!
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL S526..South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FC EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC Date 3/21/2011 Charlot-te, NC, 28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC.
Name 1850786-22
- 3. Work Performed by Work Order # (or Repair/Replacement Organization P 0 No.,.lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, C~harlo~tte,. NC 28201 -1006..
Address Expiration Date:
" N/A
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity.1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name ofManufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-5485 Duke Energy 37558 N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description Ri
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Part/Appurtenance eplaced gap support with snubber on hanger 2MCA-ND-5485 Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp. _
°F
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
14 in. (nominal)
System Class:
ASME Class_2 Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
MCFD-2561-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-5485 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MGMM15247 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 21
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina Connecticut and employed by :Hartford Steam Boiler Inspection and Insurance Company of have inspected the components described in this Owner's Report during the period
/ 7-/
to 3 /
/
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nortis employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.
JF Swan
_Commissions NC1524, N-I J" Inspector's Signature' Dat 201-National Board, State, Province, and Endorsements Date 20o//
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL 52.6 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT F(,- AEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- ,C Date 3/21/2011 Tharlotte, NC, 28201 of 2 S heet I
o Station Unit 2 Narne 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 28201-10.06 Address
- 4. Identification of System RN - Nuclear Service Water
- 5. (a) Applicable Construction Code ASME III (b) Applicable Edition of Section XI used for Repair/Replacement Activity.1998 Ec (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components 1864184-19 Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A 19 71 Edition, Summer and Winter Addenda, N/A Code Case
[ition with. the 1999 and. 2000 A-ddenda Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-RN-3215 Duke Energy N/A N/A N/A N/A Installed No
- 7. Description of Work Replaced Cornponent/Part/Appurtenance Additional Description M
- 8. Tests Conducted:
Hydrostatic r Description (Optional):
odified hanger 2MCA-RN-3215 per EC99741 Pneumatic F Nominal Operation Pressure F Exempt F7 Other F Pressure
.PSI Test Temp. _
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
6 in, (nominal)
Weld Isometric Drawing No(s).:
N/A System Class: ASME Class 2 Flow Diagram No(s).:
MCFD-2574-04.OO Support/Restraint Sketch/Drawing No(s).:
2MCA-RN-3215 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
EC99741, MCSRD-2RV-350-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date :March 21 20:11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by :Hartford Steam Boiler Inspection and Insurance Company of have inspected the components described in this Owner's Report during the period Connecticut I
7 -.
.to 2-2 =//and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied; concerning the examinations and corrective measures described in this Owner'seport. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or/c nnected with this inspection.
JF Swan___
___Commissions NC1524, N-1 Inspector's Signature Date 2--
National Board, State, Province, and Endorsements 2O _f
FORM NIS-2 OWNER'S REPORT FG.. REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASNIE Code Section XI
- 1. Owner
- 2. Plant Duke Energy Carolinas, LLC
_5.26 South_ Church Street, Charlotte, NC, 28201 Address McGuire Nuclear Station Name 12700 Hagers Ferry Road,-Huntersville, NC 28078 Address Date 3/24/2011 Sheet I
of 2 Unit 2 1864184-39 Work Order # (or Repair/Replacement Organization P.O No., Job No., etc.)
- 3. Work Performed by Duke Energy _Carolinas, LLC.
Name S/IA Type Code Symbol Stamp: !XI Authorization No.:
N/A 526 South Church Street, Charlotte, NC 28201-1006 Address N/A Expiration Date:
- 4. Identification of System RN - Nuclear Service Water
- 5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter (b) Applicable Edition of Section Xl used for Repair/Replacement Activity -1998 Edition with the 1999 and 2000 Addenda Addenda, N/A Code Case (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Nate of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-RN-3215 Duke Energ*y N/A N/A N/A N/A
[nstalled No
- 7. Description of Work Additional Description Replaced Component/Pra rt-/Appurtenanc9e Modified hanger 2MCA-RN-32 15 per EC99741I
- 8. Tests Conducted:
Hydrostatic F Pneumatic F Nominal Operation Pressure F Exempt f7 Other F Pressure
.PSI Test Tetnp. _
OF Description (Optional):
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
6 Weld Isometric Drawing No(s).:
N/A in. (nominal)
System Class:
ASME Class_2 Flow Diagram No(s).:
MCFD-2574-04.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-RN-3215 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2RV-350-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 24
,20:11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina
, Hartford Steam Boiler Inspection and Insurance Company
ýýF
.Connecticut have inspected the components described in this Owner's Report during the period
- 2.
"2
- 61 to 2-.7'
//
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any varranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspect IJF Swan
- 0.
Commissions NC1524, N-1 D tea m
Inspector's SignatUre""/
National Board, State, Province, and Endorsements
FORM NIS-2 OWNER'S REPORT Fý_ -REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASMIE Code Section XI
- 1. Owner 2. Plant Duke Energy Carolinas, LLC 526 South Church Street, Charlotte, NC, 28201 Address McGuire Nuclear Station Name 1.2700 Hagers Ferry Road, Huntersville, NC 28078 Address Date 3/29/2011 Sheet I
of 2 Unit 2 1865842-16 Work Order # (.or Repair/Replacement Organization P.O No., Job No., etc.)
- 3. Work Performed by Duke Energy Carolinas, LLC Namne 526 South Church Street,.Charlotte, N.C 28.201-10.06 Address Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System RV -
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Surnmer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998 Edition with the 1.99.9 and2_2000.Ad-denda....
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Nane ot'ManufatUrer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-RV-4173 Duke Energy N/A N/A N/A N/A Installed Yes
- 7. Description of Work Additional Description Replaced Comnponent/Part/Appurtenance installed hanger 2-MCR-RV-4 173) per EC99747
- 8. Tests Conducted:
Hydrostatic F Pneumatic F Nominal Operation Pressure F Exempt Fi Other F-Pressure _
PSI Test Temp.
OF Description (Optional):
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASNIE Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
6 in. (nominal)
System Class:
ASME Class 2 Weld Isometric Drawing No(s).:
MCFI-2RV20 Flow Diagram No(s).:
MCFD-2604-03.00 Support/Restraint Sketch/Drawing No(s).:
2MCR-RV-4 173 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
EC99747 Sheet 2 of 2
Applicable Manuhacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 29
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected.the components described in this Owner's Report during the period to *3..-.
/
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descriteýi in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither e Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspecti JF Swan II *07,,,
.*_*.../
Comrnissions NC1524, N-1 Inspector's Signa""- e Z/
National Board, State, Province, and Endorsements DateU 2,
20//_
- 1. Owner
- 2. Plant Duke Energy.Carolinas, LL 526 South. Church.Street,.
Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT F REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI Q.
Date 3/24/2011 Charlotte,.NC, 28201...
Sheet 1
o Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC...
Name 526 South Church Street, Charlotte, NC 28201-1006 Address 1865842-26 Work Order # (or Repair/Replacement Organization P.O. No, lob No, etc )
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System RV - Containment Ventilation Cooling Water
- 5. (a) Applicable Construction Code ASME Ill 19 71 Edition, Summer and Winter Addenda, N/A (b) Applicable Edition of Section X I used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identificantion of Cnmnonents Code Case Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name ot ManllCtUrer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-RV-4112 Duke Energy N./A N/A N/A N/A Removed No
- 7. Description of Work Ot-Additional Description D
- 8. Tests Conducted:
Description (Optional):
ter (Describe Below) eleted hanger'- MCR-RV-41 12 per EC99747 Pneumatic r-Nominal Operation Pressure F Exempt F7 Other F Pressure PSI Test Temp. _
°F
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASMIE Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
6 in. (nominal)
Weld Isometric Drawing No(s).:
N/A System Class:
ASME Class 2 Flow Diagram No(s).:
MCFD-2604-03.00 Support/Restraint Sketch/Drawing No(s).:
2MCR-RV-4112 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2RV-207-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 24
,20:11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the. State or.Province of North Carolina
, Hartford Steam Boiler Inspection and Insurance Company
-f' Connecticut F
.7
.7 have inspected the components described in this Owner's Report during the period
- tZ to
- 2.4" -/1,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor'his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner'l Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from Pconnected ith this inspection.
JF Swan
/-
Cs JFSwn y' Comlmissions NC1524, N-1 Date_1
- ictor's Signature National Board, State, Province, and Endorseinents
FORM NIS-2 OWNER'S REPORT Ft..
AEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI I. Owner
- 2. Plant Duke Energy Carolinas, LLC 526 South Church Street, Charlotte, NC, 28201 Address McGuire Nuclear Station Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Date 3/24/2011 Sheet I
of 2 Unit 2 1865844-16 Work Order # (Or Repair/Replacement Organization P.O No., lob No., etc.)
- 3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A 526 South Church Street, Charlotte, NC 2820 1-1006 Address
- 4. Identification of System RV - Containment Ventilation Cooling Water
- 5. (a) Applicable Construction Code ASME I11 19 7_1 Edition, Sunmner and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected.
ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Serial No.
Board No.
Identification Built Installed (Yes or No)
Name of Manufacturer 2MCA-RV-511I Duke Energy N/A N/A N/A N/A Inrstalled No
- 7. Description of Work Additional Description RZeplaced Component/Part/Appurtenance modified item# 9 on hanger 2MCA-RV-511I per EC99747
- 8. Tests Conducted:
Hydrostatic F-Pneumatic Fr Nominal Operation Pressure F Exempt 7 Other [-
Pressure __
PSI Test Ternp. _
IF Description (Optional):
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
6 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class:
ASME.CI.ass 2 Flow Diagram No(s).:
MCFD-2604-03.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-RV-51 I Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
EC99747 Applicable Manufaclurer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date.March 24 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a Valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Z
to
-2 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the 14ispector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or onnected with this inspecti.
JF Swanfr Commissions NC1524, N-I Z
1 Inspector's Sipnature National Board, State, Province, and Endorsements
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FG,.4EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI Date 10/20/20 10 Charlotte, NC,28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferr2y-Road, ju-nntersvill, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 28201-1006.
Address
- 4. Identification of Svstem NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME III (b) Applicable Edition of Section XI used for Repair/Replacement Activity..1.99-8 E d (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components 1883394-01 Work Order 4 (or Repair/Replacement Organization P.O No., Job No, etc. )
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A 19 71 Edition, Summer and Winter Addenda, N/A Code Case it-ion with the_19_99 and.200_0 Addenda.
Corrected,.
ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2NV 1047 Kerotest CA014-6 26712 N/A 1979 Installed.
Yes
- 7. Description of Work Rel Additional Description re
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed C omiponent/Part/Appurtenance placed disc in valve 2NV 1047 Pneumatic r-Nominal Operation Pressure Exempt F7 Other F Pressure PSI Test Temp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASNIE Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2NV303 System Class:
ASME Class 2 Flow Diagram No(s).:
MCFD-2554-03.00 Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not includedelsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are con'ect and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October20 20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut
- have inspected the components described in this Owner's Report during the period
-6.)
to /6
-1', * /Cand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's !yport. Furthermore, neither the Ins tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or nnected with this inspection.
JF Swan
-Commissions
.NC 1524, N-I o
SNational Board, State, Province, and Endorsements Date 22Du 20.
FORM NIS-2 OWNER'S REPORT k
. REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASIME Code Section XI
- 1. Owner
- 2. Plant Duke Energy Carolinas, LLC 526 South Church Street, Charlotte, NC, 28201 Address McGuire Nuclear Station Name Date 3/11/2011 Sheet I
of 2 Unit 2 12700 Hagers Ferry Road,.Huntersvi.!le, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas,. LLC Name 526 South Church Street,.. Charlotte,.NC-28201-1006 Address 1892972-03 Work Order P (or Repair/Replacement Organization P.O. No., Job No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A 4.
5.
6.
Identification of System NS - Containment Spray (a) Applicable Construction Code ASME 11I 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X I used for Repair/Replacement Activity.1998 Edition with the 1999 and 2.000.Addenda.
(c) Applicable Section XI Code Case(s) N/A Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped C n Name of Manufacturer Serial No.
Board No.
Identification Built
.2MCR-NS-4767 Duke Energy N/A N./A N/A N/A Installed
'No t
4 4
4
.4-5 4
4 4
4
.4.
5 4
4 4
4
-4.
4 r
1 1
1 4
+/-
4
- 7. Description of Work Replaced Component/Part/Appurtenance Additional Description In
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
stalled 4 item# 8s (1/2" x 3 1/2" x 6" plates) on hanger 2MCR-NS-4767 per EC101538.
Pneumatic F" Nominal Operation Pressure r-Exempt F Other '-
Pressure
-PSI Test Temp. _
IF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
8 in. (nomninal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class:
ASME Class 2 Flow Diagram No(s).:
MCFD-2563-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCR-NS-4767 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
EC101538 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F L Grass, Quality Assurance Technical Specialist
\\'
.4-Date March 11 20 11 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own0 Is Report. Furthermore, neither the Ins ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro Ibr connected with this inspection.
JF Swan 1
/,
Commissions NC1524, N-1 (I
Insp/ctor's sS, Da
-3 gnaturV
/4 National Board, State, Province, and Endorsements 20_/_1
- 1. Owner
- 2. Plant FORM NIS-2 OWNER'S REPORT,
. REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASNME Code Section XI
.uke Energy Carol-inasjLIC.
Date 4/6/2011 526 South Church Street, Charlotte, NC, 2820_1......
Sheet I
of 2 Address McGuire Nuclear Station Unit 2 Name 12700 Hagers Ferry Road, H.untersvill.e.,NC 28078 Address 1897283-11 Work Order 9 (or Repair/Replacement Organization P.O. No., lob No., etc )
- 3. Work Performed by Duke Energy Carolinas,. LLC Name Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
526 South Church Street, Charlotte, NC. 28201-1006.
Address
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME I11 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name ot Manufacturer National Other Year Removed, or Stamped Component Name of Manulacturer Serial No Board No.
Identification Butilt Installed (Yes or No)
NV Piping Duke Energy N/A 80 2NVFE5300 1982
- 7. Description of Work Additional Description Rep lacec.. Com~ponent/Patrt/Appj~urtenance replaced bolting material in flange at 2NVFE5300
- 8. Tests Conducted:
Hydrostatic -'
Pneumatic -"
Nominal Operation Pressure Description (Optional):
test performed per prc*edure MP/0/A/7700/045.
Exempt I-Other F-Pressure PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
System Class: ASMEClass 2 Flow Diagram No(s).:
MCFD-2554-O 1.01 Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
\\7
,i---
Date April 6
-20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned,.holding a valid commission issued by theNational Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina r
In PA. a
, Hartford Steam Boiler Inspection and Insurance Company nýF
'Connecticut have inspected the components described in this Owner's Report during the period
- .9.*"C:Q--[_'to
-'7
./.
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fron/rr connected with this ins ction.
JF Swan z;.,,4-.
Commissions NC 1524, N-I Date 0-Inspector's National Board, State, Province, and Endorsements 20o/
Date 20 / 1
I. Owner
- 2. Plant Duke Energy Carolinas, LL
.526_South Church _. Street-Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT k. REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI C.Date 4/6/2011 Charlotte, N.C, 2.8201_..
Sheet 1
of 2 Station Name 12700 Hagers Ferry Road, Huntersyille,.N.C 28078 Address
- 3. Work Performed by Duke Energy.Caroli.nas, LLC Name Unit 2 1897290-07 Work Order (or Repair/Replacement Organization P.O. No,,lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 4.
5.
6.
526 South Church Street, Charlotte,.NC 28201-1006 N/A Address Expiration Date:
Identification of System NV - Chemical and Volume Control (a) Applicable Construction Code ASME Il1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity
.1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A Identification of Camn"onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No)
NV Piping Duke Energy N/A 80 N/A 1982 Installed Yes
- 7. Description of Work Replaced Component/Part/Appurtenance Additional Description replaced bolting material in flange 2NVFE5330
- 8. Tests Conducted:
Hydrostatic FV Pneumatic E-Nominal Operation Pressure F'_
Description (Optional): test performed perprocedure.MP P//A/7700/045.
Exempt F-Other r-Pressure PSI Test Temp. __
F
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
2 in. (norninal)
Weld Isometric Drawing No(s).:
MCFI-2NVI80 System Class: ASME.Class2 Flow Diagram No(s).:
MCFD-2554-01.00 Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date 'April 6
, 2 0 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
_ Z t
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report 'in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspect*
JF Swan
.b,,.
-AS Commissions NC1524,N-1 Date (ý,
Inspector's Signalt i/Jr7 National Board, State, Province, and Endorsements 1 20 //
- 1. Owner
- 2. Plant FORM NIS-2 OWNER'S REPORT I
. REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X I Duke Energy Carolinas, LLC Date 4/2/2011 526 South Church Street, Charlotte, NC, 28201 Sheet I
of 2 Address McGuire Nuclear Station Unit 2 Name 12700I Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church.Street, Charlotte, NC. 2.8201-1006 Address 1900003-04 Work Order 9 (or Repair/Replacement Organization P.O No., Job No., etc.)
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
- 4. Identification of System NV - Chemical Volume And Control
- 5. (a) Applicable Construction Code ASME-II 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Serial No.
Board No.
Identification Buit Installed (Yes or No)
Name of Manufiacturer 2NV 155 Dresser TE09049 293 N/A 1978 Removed No 2NV 155 Dresser TH03994 1936 N/A 1987 Installed No
- 7. Description of Work Additional Description Replaced Component/Part/Appurtenance replaced valve 2NV 155
- 8. Tests Conducted:
Hydrostatic F Pneumatic F Nominal Operation Pressure [
Description (Optional):
test performed perprocedlure M.P/O/A/770_/ 045 Exempt r-Other r-Pressure PSI Test Temp. _
IF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
4 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class: ASME Class 2 Flow Diagram No(s).:
MCI Support/Restraint Sketch/Drawing No(s).:
N/A FD-2554-O2.O I Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date :April 2
,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and ernnloved hv Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Z
//
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's eport. Furthermore, neither the In ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from onnected with this inspection.
JF Swan Commissions NC1524, N-I Inspector's Signature "
Dat "201/
National Board, State, Province, and Endorsements
I. Owner
- 2. Plant
.Duk-e.Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT I REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
.Date 4/3/2011 Tharlotte, NC, 28201..
Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road,.Huntersville,..NC 28078 1900647-05 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
- 3. Work Performed by Duke.Energy Qauolinas, LLC Type Code Symbol Stamp:
N/A Name Authorization No.:
N/A 526 South Church Street._Charlotte, NC 28201-1006 Address Expiration Date:
N/A
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998 Edition with the_.19.99.and 2000 Addenda...
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2NV229 Dresser TE09051 262 N/A 1978 Re.moved Yes 2NV229 Dresser TE09050 261 N/A 1978 Installed Yes
- 7. Description of Work Replaced Component/Part/Appurtenance Additional Description replaced relief valve 2NV229
- 8. Tests Conducted:
Hydrostatic F Pneumatic r-Nominal Operation Pressure F Description (Optional): test.performed per procedure M.P/O/A/7700/045.
Exempt r-Other i-Pressure PSI Test Temp.
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet.2 of 2 Component Line Size:
1 1/2 x 2 in. (nominal)
Weld Isometric Drawing No(s).:
N/A System Class:
ASME Class 2 Flow Diagram No(s).:
[vICFD-2554-03.O1 Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date April3
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
...*S zi**..to an statethattothebestofmyknowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's eport. Furthermore, neither the In ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o onnected with this inspection.
.JF Swan Commissions iNC1524, N-I 0*
Inspector's Signature JNational Board, State. Province, and Endorsements Date*
-)-
2
FOR)4 NV-I N CERTIFICATE HOLDERS* DATA REPORT FOR SAFETY AN; SAFETY RELIEF VALVES*
(AS REQUIRED BY THE PROVISIONS OF THE ASNIE CODE.
SECTION-III. DIV.
1)
I.
14m.
'.TURED BY DRESSER INDUSTRIAL VALVE & INSTR, DIV.
HIGK',XAY 71 NGRqWT ALEXANDRIA, LOUISIANA (NA2E AND ADDRESS OF
.i CERTIFICATE HOLDER)
- 2.
MAiUFACTURED FOR Mill Power Supply Co.,P.O. Box 1339, Charlotte, NC 28232 (HANME AND ADDRESS OF PIURCHASER OR OIWNER)
- 3.
LOCATION OF INSTALLATION Duke Power Co.,McGuire Nuclear Sta., Cowans Ford, NC (NAME AND ADDRESS) 4 3NC3004
ýi) 1978 (CNN)
(DRAWING NO.)
(H AT Nf*'t0 (YEAR BUILT)
- 5. VALVE ;I-12-/)1910-30F/S4-1LXRL1-NC3004 IDENTIFYINGNO.
/E95 (MODEL NO..SERIES NO.)
'(N
_CEaRS SERIAL.NO.f TYPE Safety Relief CLASS n2 (SAFETY.SAFETY RELIEF; PILOT;POWlER A4,t A:fD)
ORIFICE SIZE
.650 NOMINAL INLET SIZE 1-1/2" OUTLET SIZE 2"
INCH INCH INCH B. SET PRESSURE (PSIG) 220 RATED TEMPERATURE 189 0F STAMPED CAPACITY 3753 LBS/HR.
SAT.STEAAM
@ 10
% OVERPRESSURE BLOWOOIN (PSiG) 11.0 HYDROSTATIC TEST (PSIG)
INLET
- See.Below
- 7.
PRESSURE RETAINIKG PIECES SERIAL NO.
OR IDENTIFICATION OUTLET N/A (APPLICABLE TO VALVES FORCLOSED SYSTEMS ONLY)
MATERIAL SPECIFICATION INCL.
TYPE OR GRADE BODY BONNET OR YOAE SUPPORT RODS NOZZLE DISC SPRIN3 WASHERS ADJUSTING SCREW SPINDLE Head SPRING BOLTING OTHER PIECES AAD60 SA351 Cr. CF8M AAE32 SA351 Cr. CF8M AAA69 SA182 Gr. F316 X16110 SA182 Gr. F316 G9345/G9064 SA479 Type 316/SA182 Gr.
316 G9380 SA479 Type 316 G9380 SA479 Type 316 88540 ASTM A313 Type 316 Disc Holder Base stild5, r
G9392 C.I(I I SA182 Cr. F316 SA453 Gr.
660
_qA1 QL r.r GKI I Base stild N11t.q r, K6
- SUPPLEMENT SHEETS IN FORM OF LISTS.SXETCHES OR DRAIIHGS MAY BE USED PROVIDED (1) SIZE IS 8-1/2" v,I" (2) INFORNATION IN ITE3S 1-2 ON THIS DATA REPORT IS INCLUDED ON EACH SHEET, AND (3)
EACH SHEET IS HUNBEREU AND NUMBER OF SHEETS IS RECORDED AT TOP OF THIS FORM.
OArOO71-0178
FOr*HV-I (PACK)
=
FORN4 NY-I (BiACK)
CERTIFICATE OF COMPLIANCE VE CERTIFY THAT THE STATEMENTS MADE IN THIS REPORT ARE CORRECT AND THAT THIS VALVE CONFORNS TO THE POLES OF CONSTRUCTION OF THE ASME CODE FOR NUCLEAR POWER PLANT COMPONENTS.
SECTION 111, DIV.I.
1971' EDITION.
ADDENDA Summer 1973 CODE CASE NO.
N[A (DATE)
DATE 1-27-78 SIGNED Dresser IVID BY,/
(N CERTIFICATE HOLDER)
Princ al Q.A. E gineer OUR ASNE CERTIFICATE OF AUTHORIZATION NO.
N-1747 TO USE THE, NV SYMBOL. EXPIRES Nay 20, 1980 My (N)
(DATE)
CERTIFICATION OF DESIGK DESIGN INFORNATION CN FILE AT Dresser Plant, Alexandria, La.
STRESS ANALYSIS REPORT (CLASS I ONLY)
ON FILE AT DESIGN SPECIFICATIONS CERTIFIED BYI T.
F.
Wyke PE STATE North Carolina REG. NO.
4870
.STRESS REPORT CERTIFIED BYI PE S.TATE REG.NO.
1SICHATURE NOT REOUIRED-LIST NAME ONLY CERTIFICATE OF SHOP INSPECTION I.THE UNDERSIGNED.
HOLDING A VALID COMXISSIOH ISSUED BY THE NATIONAL BOARD OF BOILER AND PRESSURE VESSEL INSPECTORS AND THE STATE OR PROVINCE OF LOUISIANA AND EMPLOYED BY THE HARTFOM9 STS-.
BOILER I-&.
C04A?4Y OF RARTFO.", CONN..
HAVE iNSPECTED THE PUMP.OR VALVE.DESCRI,3ED IN THIS DATA REPORT ON 197I2ANOD STATE THIAT TO THE REST OF LY KNOWLEDGE AND BELIEF.THE N CERTIFICATE HOLDER HAS CONSTRUCTED.TNI$S
- PUNP, OR.VALVE.
IN ACCORDANCE WITH THE-ASME CODE FOR NUCLEAR POWER PLANT COMPONENTS.
BY SiNINg THIS CERTIFICAIE.
NEITHER THE INSPECTOR NOR HIS EMPLOYER MAKES ANY VARlffrrY.EXPRESSED OR IMPLIED.
CCHCERNiNtG THE EOJIPFENT OESCRIBED IN THIS DATA REPORT.FUTHERMORE.HEITHER THE INSPECTOR NOR HIS ENPLOYER SHALL BE LIABLE IN ANY MANNER FOR ANY PERSONAL INJURY OR PROPERTY DA4AGE OR A LOSS OF ANY KIND ARISINg F101 OR CONtE'TTED 1ITHT'HIS INSPECTION.
DATE.Ma[rch27.,ta 78 SIGNEO COmmISSIOnS. National Board No.
7779 (INSPECTOR)
(NATIL.BD.STATE PROV.AND NO.)
k
~cs~i;.h~. O~ -COil-OTTO
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT F(
.EPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASMIE Code Section XI C
Date 3/26/2011 Charlotte, NC, 28201.
Sheet 1
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC.
Name 1907056-14 Work Order # (or Repair/Replacement Organization P.O. No., lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC 28201-1006 Expiration N/A Address Expiration Date:
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity.1998 Edition with the1999.and 20.00 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification ofComponents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-NV-5050 Duke Energy N/A N/A N/A N/A Installed No
- 7. Description of Work Rer Additional Description Re
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Part/Appurtenance
- placed item# 7 (2x2 tube steel) on hanger 2MCA-NV-5050 per EC 104199.
Pneumatic F Nominal Operation-Pressure F Exempt F Other F Pressure PSI Test Temp.
F
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:.
in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class:
ASME Class 2 Flow Diagram No(s).:
MCFD-2554-03.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-NV-5050 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2NV-350-00I Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed ::FL Grass, Quality Assurance Technical Specialist
\\
Date March 26
.20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NHartford Steam Boiler Inspection and Insurance Company North Carolina and employed by oof Connecticut have inspected the components described in this Owner's Report during the period
- Z(
to - 2-b -//
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither th spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from *connected with this inspection JF Swan
/[e
'-,07 _.
/
,6,u-Commissions NC1524, N-1 Dater Inspector's Signature.,,-/'
National Board, State, Province, and Endorsements 20//-
fl~ rp 201/
I. Owner
- 2. Plant Duke.Energy Carolinas, LI
.526_South. Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT F(
AEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI S.
Date 4/3/2011 Charlotte,. NC,28.201.
Sheet I
of 2 Station Unit 2 Name 12700 Hagers. Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 1907056-02 1907056-02 Work Order 9 (or Repair/Replacement Organization P 0 No., lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC 28201-10.06 N/A Address Expiration Date:
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1.99.8 Edition with the 199_9 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No)
NV Piping Duke Energy N/A 80 N/A 1982 Installed Yes 2NV494 Flowserve E990A-2-3 2356 Body S/N 3 2000 Installed Yes 2NV494 Borg Warner 8003 53 N/A 1976 Removed Y e..S
- 7. Description of Work Additional Description Replaced.Component/Part/Appurtenance Replaced valve 2NV494 and piping per EC104199.
- 8. Tests Conducted:
Pneumatic -
Nominal Operation Pressure P Description (Optional): test performed p[er procedure.MP/0/A/7650/076.
Exempt --
Other --
Pressure 2516 PSI Test Temp. 86.1 OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
System Class: ASME Class_2 Weld Isometric Drawing No(s).:
MCFI-2NV294 Sheet 2 of 2 Flow Diagram No(s).:
MCFD-25554-03.00 Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
EC104199 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
,,.c-t, Date April 3
,20.11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
.Connecticut have inspected the components described in this Owner's Report during the period
~ Z/ I
- /7-to
,and state thato the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in an), manner for any personal injury or property damage or a loss of any kind arising from o connected with this inspection.
JF Swan Y
- Commissions NCI 524, N-lI
- National Board, State, Province, and EndorsenenIs Date 2o/_./_
Jun-15-]O 01:55pm From-FLOWSERVE WILLIAUSPORT
+T]73274922 T-642 P.01/04 F-513 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVESI As Required by the NIovLuions of the ASME Code, Section Ill. Divizion 1 I.
2 Pg.
of Flowserve Corp.
701 First Srreet, Williamsport.,
PA 17701 1
manui.taured 3n3 canft.-,a Oy
°..
n 1nal A 4l10011 01 N C.
MT.?,Cato MOO9 2
1 Duke Energy Corporation, P.O.
Box 1015, Charlotte, NC.
28201-IO15.
- 2. MaI utaclufc0 t (e'uinl 1*2l'e 0 ? Pjrnagim.If o O.n.e,e.
McGuire Nuclear Starion, 13225 hagers Ferry Rd.,
Highway 73, Huntersville, NC.
I1 Lac3tion of instauation
- 3.
a m 0clre""
'2 8 0 28 -8 9 8 5.
- 4. MOceI No., Serris No.. orT Y-Globe W9925265 Rau A
cRNN/A
- 5. ASME Coce. Section Ill. D,,isson 1:
1986 N/A N/A Wa~bbofn fiagoatnca cai*ni 104S3 4cocit C-*Oz -o I
8 Purp ar avalve Nomianal -nift s O&tie $Saz 2
SA351-CF8M 5A479-316 5A564-630-1C75 N/A 7
Material: floor Bonnlux OISI.
~
n lal aNo.
Sanas NO.
E990A 1 E990A-2-2 E990OA-2T E99 OA-2-4 E990A 5 to]
Na.'l NB9 2354 NB# 2355 NB# 2356 NB# 2357 NB#
2358 tC' Boav No.
SN: I SN: 2 SN: 3 SN: 4 SN: 5 (01 Bonne No.
HT#48908 Pc 2 HT448908 Pc 3 HT#48908 Pc 4 HT#48908 Pc S to) omsr Soara No HTT86684 Y-HT48656804 (TXY)
HT#8656804 (TX'i)
HT#8656804 (TXY)
HT48656804 ATXY) 0 5.vbcUmiivn
.15rmtxmWSW
'n birn 0? t 4=.
3&=Cr%i. Or *iWVsg MaY 06.0
".o-do bi A
.5 Bt s
- 11. 121 iom stbionbd nS.%am* I dIfirgb 4
.2nS tN, Oat Raoeort mi
,ucaao an.acri zriest. t31 eacri usa.?. nmbarooria ucrta p%.mw of a, Ioss -a 4K(obOOO at Ma Wog Or M5g bIrn (1 21861 Th~a vwm tE i0OO37i ma, ci6 oouata from vma Ownir Dept.. ASME-. 22 La. On. a. Sax 2300. Fwa..nm.
NJ O70O07.2rp
/~1Tf/:< /~d~V 764-1 qoo
Jun-15-00 01:55pm From-FLOWSERVE WILLIAMSPORT
+7173274922 T-642 P.02/04 F-513 FORM NPV-1 (back)
Serial Numbers: E990A-2-1 through E990A-2-5 Material; Gasket Retainer: SA564-630-1075; Cast#700781; Code: WGT.
- 9. Nsign conaalom 2735 680 "F or..,
prussure cla=
1878 iII
( preisuf"a1 l Iamleun','1*
- 10. Cold,workig pres3ure 4507 it a iooF0 1 1. H~yarcistatic tes-t 6775 ps,.
u;"* ataeonza,* cast prats.urn 4958 psi CERTIFICATION Of DESIGN F. A. Bensinger PA PE-31002-E Design soficao_
cf_
by FAensnP.E.
Stae Ag. no.
oesign Aeporz Certifie by Theron C. Bartlett I11 P.E. sra PA R.g no.
PE-039036-E CERTIFiCATE OF SHOP COMPLUANCE we carutf met me statements made,n xr" teport are corTect aiax mat mis pump or val-. conforms 'o te rules for construjction of trio ASME CocOa.Section III. Dhv.a.on 1.
N Certificate of AtnOrnzation No N1712 Epr, __ 4/15/01
,'WLDat 8 ame E1otserve Corp.
Signed e
[L 6
iN C1&rficme Malawi) toIral bO,greaoprolotat-al CERTICATE OF SHOP MISPECT"ON I. me undersigned. ho*Ling a vatic cOzmrw'4on a
z.rjo, d by, ife. Natiorial Board of B-odat &no Prxivure Vedsseo Inspectors ann Tr*ni szale
- J;ý Of per'nsylvai*ria an. employed yCor*nerci;al Union Ins.
Co.
.07 a
r*
la.o inspaecte the purp. of valve. desc.ibed in tmhs Date Repor* On 1-3
.. -- /.
and state ina t o trio m-e of my knowledge and belief. me Certificate Holoer has cons;njCEC Mtts Dump. Of valve,,n accordance witri Me ASME Coco, Secison lit. O;v;aion 1.
8y sigruN mis cartmficate. netul"r the tl:n cor nor tia employer makes anty warranty, expf'ssec or implieOd. conc.rn*ng tmel componeont described in tir3 Data Report. F-wr'rcrmo4'e. naotmeor Te inspector nor isz emplOvOyr somll be haole in any manner fOr any personal injury or ptoperrvy Damage or oa any kind aLrsng trom of corn'cted wrt tnhi,iln e ii--o.___
Date S/
Counm4om Pennsylvania 2392 44^,*
'q,*
re**'5'V70
- '0oVL.
So. o.
w.%oar -inj mta or pir,. a.d ;.).
i II For mri-rtally Opera-ted 'akwsve only.
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI
..526 South Church Street,.
Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOi ZPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI LC Date 3/9/2011 Charlotte, NC, 2820 Sheet 1
of 2 Station Unit 2 Name 12.700.Hagers Ferry Road, Huntersville, NC 280.78 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte,. NC 2820l!-.l006.
Address 1922371-01 Work Order I9 (or Repair/Replacement Organization P.O. No, Fob No.. etc Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System SM - Main Steam
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity.1998 Edition with the 1999 and_2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Com onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Serial No.
Board No.
Identification Built Installed (Yes or No)
Name of ManufacturerSeilN.BadN.detfctoBulInald (YsrN) 2MCA-SM-20 Duke Energy 21359 N/A
- N/A N/A Removed No 2MCA-SM-20 Duke Energy 37227 N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description Rt
- 8. Tests Conducted:
Hydrostatic r Description (Optional):
placed Com pon.ent/Pa.rt/Appurtegnan.ce eplaced snubber on hanger 2MCA-SM-20 Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure
" PSI Test Temp. _
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
42 in. (nominal)
Weld Isometric Drawing No(s).:
N/A System Class:
ASME Class 2 Flow.Diagram No(s).:
MCFD-2593-0 1.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-SM-20 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2SMA-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration.Date N/A Signed FL Grass, Quality Assurance Technical Specialist 4
- S,,
Date March 9 2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina andc emnonved bv Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
-to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither td Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fromn r connected with this inspection JF Swan (I*
AZv-L..------
Commissions NC 1524, N-I e
Inspector's Signature Date (-
/,
.National Board, State, Province, and Endorsements 20-d/
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL 526 South.Church. Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOi.
ZPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 3/8/2011 Charlotte, NC,.28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 1922374-01 Work Order # (or Repair/Replacement Organization P O. No, lob No., etc I Type Code Symbol Stamp:
N/A A
0,t
- ,t;,,
X1,-
N/A
- 3. Work Performed by 526 South Church Street, Charlotte, NC 28201l-1006
__-.N/A Address Expiration Date:
N/A
- 4. Identification of System CA - Auxiliary Feedwater
- 5.
(a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1.99_8.Edition with the 19_99 and 2000 Addenda, (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name ofMiutlCttrer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-CA-60 Duke Energy 18871 N/A N/A N/A Removed No 2MCA-CA-60 Duke Energy 37226 N/A N/A N/A Installed NO
.4-4 4
+
+
+
1 1
r
.4-5 1
7 1
r
.1.
1 _____________________
.4 ___________________
+/- ___________________________
a ___________________
- 7. Description of Work Rel Additional Description re
- 8. Tests Conducted:
Hydrostatic F' Description (Optional):
placed. Com ponent/Part/Appurte-nance placed snubber on hanger 2MCA-CA-60 Pneumatic F Nominal Operation Pressure -.
Exempt r-Other r Pressure
.PSI Test Temp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
6 in. (nominal)
Weld Isometric Drawing No(s).:
N/A System Class: ASMEClass 2 Flow Diagram No(s).:
MCFD-26 17-0 1.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-CA-60 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code. Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 8 20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina Hartford Steam Boiler Inspection and Insurance Company Connecticut have inspected the components described in this Owner's Report during the oeriod and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or cnected with this inspection.
JF Swan r
I Commissions.NC1524, N-1 Inspector's Signature.1 Date J 1 ec t
o
, 2 0..
National Board, State, Province, and Endorsements
FORM NIS-2 OWNER'S REPORT FOR PAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC
.Date 3/7/2011
- 1. Owner
- 2. Plant
.Duke Energy Carolinas, Li
.526 SouthChurch Street, Charlotte, NC, 28201.
Address McGuire Nuclear Station Name Sheet I
of 2 Unit 2 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 28201-1.0.06 Address 1923830-02 Work Order # (or Repair/Replacement Organization P.O. No, Job No, etc Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System NC - Reactor Coolant
- 5. (a) Applicable Construction Code ASME III (b) Applicable Edition of Section XI used for Repair/Replacement Activity 19 71 Edition, Summer and Winter Addenda, N/A 1998 Edition with the 1999 and 2000 Addenda Code Case (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2D S/G Lisega Duke Energy 9
N/A
- N/A N/A Installed No
- 7. Description of Work Additional Description Replaced Co nmp on0ent/Pa-rt/,A.p p.u.rten an._e Replaced #4 rear valve and #5 cone valve in snubber for 2D Steam Generator
- 8. Tests Conducted:
Hydrostatic f-Pneumatic r-Nominal Operation Pressure r-Exempt F7 Other r-Pressure PSI Test Temp. _
OF Description (Optional):
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
N/A in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class: ASME Class 2 Flow Diagram No(s).:
N/A Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCM 1117.03-0053.001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
.Date March 7
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
'.3.
iL.- -/
to
--Lc -
iL." *L and state that to the best of my knowledge and belief, the Owner has performed examinations and taketn corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Ins ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspection.
SCommissions'NC1524, N-I Inspectors Signature National Board, State, Province, and Endorsements Date 20
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL 526 South Church Street, Address M.cGuire Nuclear FORM NIS-2 OWNER'S REPORT FOi.
EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI CDate 3/25/2011 Tharlotte, NC, 28201 Sheet 1
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville_,NC 28078 Address
- 3. Work Performed by Duke Energy.Carolinas, LLC Name 1923837-19 Work Order P (or Repair/Replacernent Organization 13.0. No., lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC 28201-1006 N/A Address Expiration Date:
N/A
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the. 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-NV-4379 Duke Energy N/A N/A N/A N/A Installed No 2MCR-NV-4380 Duke Energy N/A N/A N/A N/A Installed No 2MCR-NV-4381 Duke Energy N/A N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description Rt
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Part/A~ppurte.nance eplaced the bolting material on hangers 2MCR-NV-4379, 4380, and 4381 per EC105482 Pneumatic F Nominal Operation Pressure --
Exempt F Other F Pressure PSI Test Temp. _
IF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
2 in. (nominal)
System Class:
ASMD5Class1 Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
MCFD-2554-0 1.01 Support/Restraint Sketch/Drawing No(s.pCANca,48 andr43 Other Applicable Information (e.g., WO. No., EC No.) if not included elsewhere on NIS-2 Form: o MCSRMD-2NV-209-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 25
, 20 11 Owner or Owner's Designee, Title
/
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
- Connecticut have inspected the components described in this Owner's Report during the period S-11 {
to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither thed nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or onnected with this inspection./
JF SwanCommissions NC 1524, N-I Inspector's Signature
/National Board, State, Province, and Endorsements Dat 3-20
I. Owner
- 2. Plant Duke Energy Carolinas, LL 526.South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FC EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- C Date 3/21/20 11 Charlotte, NC, 28201 Sheet I
of 2 Station Unit 2 Naine
- 3. Work Performed by 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Narne 526 South. ChuTch Street,.Charlotte, NC 28201-1006.
Address Work Order # (or Repair/Replacement Organization P.O. No.,.lob No., etc.)
1923857-28 Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME I11 19 7.1 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998 Edition with th-e_.1999 and 200OAdd.enda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of ManufactUrer National Other Year Removed, or Stamped Component Naite 01Mantiturer Serial No.
Board No.
Identification, Built Installed (Yes or No) 2MCA-NV-6523 Duke Energy N/A N/A N/A N/A Installed No
- 7. Description of Work Replaced Coin ponent/Part/Appurtenance Additional Description re
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed pivot pin on hanger 2MCA-NV-6523 Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure
.PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASNIE Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
3 Weld Isometric Drawing No(s).:
N/A in. (nominal)
System Class: ASME.Class.2 Flow Diagram No(s).:
MCFD-2554-0 1.02 Support/Restraint Sketch/Drawing No(s).:
2MCA-NV-6523 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FLGrass, Quality Assurance Technical Specialist 2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
.North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period J
/
_to__.___--_...2.-._-____
, and state that to the best of my knowledge and belief, the Owner has performed exarninations and taken corrective measures cescribed in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner'skeport. Furthermore, neither the In ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o 'Ionnected with this inspection.
.JF Swan Commissions NC 1524, N-I nspectors Signature
/
Date
.3 "-72----
/
National Board, State, Province, and Endorsements
.20j
-/
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOK.,EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI LC Date 3/21/2011 CharlotteNC, 28201 Sheet 1
of 2 Station Unit 2
- Narne 127.00 Hagers Ferry Road, Huntersyille, N.C 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC.
Name 526 South.Church Street, Charlotte, NC_28201-.1:006 Address 1923857-45 Work Order # (or Repair/Replacement Organization P C. No, lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System NC - Reactor Coolant
- 5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the...1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No)
.2MCR-NC-4000 Duke Energy 3605 N/A N/A N/A Removed No 2MCR-NC-4000 Duke Energy 38038 N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description re
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
placed Component/Part/Appurtenance placed snubber on hanger 2MCR-NC-4000 Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of. 2 Component Line Size:
14 in. (nominal)
Weld Isometric Drawing No(s).:
N/A System Class: ASME.Class.I Flow Diagram No(s).:
MCFD-2562-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCR-NC-4000 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2NC-201-001, PIP# M-1 1-01899 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, QUality Assurance Technical Specialist
\\7 Date March 21
,0 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina
- Connecticut and employed by Hartford Steam Boiler Inspection and Insurance Company of have inspected the components described in this Owner's Report during the period 3 -,/ `7-' ý/
to.3 -
2
- 1/, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from ed with this inspection.
F Swan
~Commissions NC1524,rN-I Dt Inspector's Signature 1/0/
Date 2-2 National Board, State, Province, and Endorsements 2o0
FORM°NIS-2 OWNER'S REPORT F6O. -EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI C..
Date 3/11/2011
- 1. Owner
- 2. Plant Duke.Energy Carolinas, LL
..526 South Church Street, Charlotte, NC, 282.01 Address McGuire Nuclear Station N arm e 12700 Hagers Ferry Road,.Huntersvile, NC 28078 Address Sheet I
of 2 Unit 2 1923857-49 Work Order 0 (or Repair/Replacement Organization P.O. No., lob No. etc
- 3. Work Performed by Duke.Energy Carolinas, LLC Name Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
526 South Church Street, Charlotte, NC 28201-1006 Address N/A
- 4. Identification of System NI - Safety Injection
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda Addenda, N/A Code Case (c) Applicable Section XI Code Case(s) N/A 6, Identification of Components Corrected.
ASME Code Name of MNanuifacturer National-Other Year Removed, or Stamped Component Name of MattufactUrer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-N[-4589 Duke Energy
.2816 N/A N/A N/A Installed No
- 7. Description of Work Additional Description Replaced Component/Part/Appurtenance.
Replaced load pin in hanger 2MCR-NI1-4589
- 8. Tests Conducted:
Hydrostatic F Pneumatic F' Nominal Operation Pressure F" Exempt 1F Other F Pressure PSI Test Temp. __
Description (Optional):
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
10 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class:
ASME Class 2 Flow Diagram No(s).:
MCFD-Support/Restraint Sketch/Drawing No(s).:
2MCR-NI-4589 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2N1-203-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 1I 1)011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
- Connecticut have inspected the components described in this Owner's Report during the period
".31-f..L[L[
to "2, - /
- 1/
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.
JF Swan Commissions NC 1524, N-I 1__7 Inspector's Signature
.x' National Board, State, Province, and Endorsements
/_/__
- 1. Owner
- 2. Plant Duke. Energy Carolinas,. L 526 -Sou.th.Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO.
.EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI Date 3/11/2011 Charlotte,.NC,..2.8201..
Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road.,Huntersville, NC 28078 Address Duke Energy. Carolinas, LLC..
Name 1923 85 7-62
- 3. Work Performed by Work Order # (or Repair/Replacement Organization P 0 No., lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church St reet._Charlotte, NC 28201-1006 N/A Address Expiration Date:
- 4. Identification of System BB - Steam Generator Blowdown Recycle
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998. Edition with.the 1_9.99_and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No)
.2MCA-BB-5218 Duke Energy 10425 N/A N/A N/A Removed No
.2MCA-BB-5218 Duke Energy 38035 N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description re
- 8. Tests Conducted:
Hydrostatic r Description (Optional):
tlaced Compon.ent/Part/A.ppurternanrce placed snubber on hanger 2MCA-BB-52 18 Pneumatic F-Nominal Operation Pressure F Exempt F Other F Pressure
.PSI Test Temp. _
FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section X I
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
4
-in.
(nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class:
ASME C.lass. 2 Flow Diagram No(s).:
MCFD-2580-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-BB-52 18 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March11
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
- North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report durincr the period i.w.* -*
/
z to.--
Z//'
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fromy*r connected with this inspection.
.JF Swan 6 //7 Commissions NC1524, N-1 D tea Inspector's Signature National Board, State, Province, and Endorsements 2~- i'1 20-9_
D te 2016
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FG.. AEPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
.Date 3/11/2011 Charlotte, NC, 28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name
- 3. Work Performed by 1923857-68 Work Order 9 (or Repair/Replacement Organization P.O. No., tob No, etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 4.
5.
6.
526 South Church Street, Charlotte, NC 28201-1006 N/A Address Expiration Date:
Identification of System VS - Station Air System - Station Air System (High Pressure)
(a) Applicable Construction Code ASME [II 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacernent Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A Identification of Components Corrected.
ASME Code Nameof Manutaciurer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2-MCR-S-VS-150-01-1 Duke Energy 6342 N/A N/A N/A Removed No 2-MCR-S-VS-150-01-1 Duke Energy 38034 N/A N/A N/A Installed No
- 7. Description of Work Re Additional Description re
- 8. Tests Conducted:
Hydrostatic r Description (Optional):
placed Component/Part/Appurtenance placed snubber on hanger 2-MCR-S-VS-150-01-1 Pneumatic --
Nominal Operation Pressure F Exempt 7" Other F-Pressure PSI Test Temp. __
IF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
System Class:
ASMEClasss2 Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 Flow Diagram No(s).:
N/A Support/Restraint Sketch/Drawing No(s).:
2-MCR-S-VS-150-01-1 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requiremnents of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March II 2)0 I1I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by "Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
-to
-. 31 9
and state that to the best of my knowledge and belief, the Owner has perforned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspecti JF SanCommissions NC1524, N-I Inspector's Signature National Board, State, Province, and Endorsements
,ate
-)"o 0.f/
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOk..EPAIRJREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 3/21/2011 Charlotte, NC, 28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charl.otte,.NC 2820 1-1006 Address 19233857-69 Work Order # (or Repair/Replacement Organization P 0 No., lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System NI - Safety Injection
- 5. (a) Applicable Construction Code ASME 11 19 71. Edition, Summer and Winter Addenda,, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity.1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Naome ofn Manut'aclurer National Other Year Removed, or Stamped Component N
e MatfaCtUrer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-NI-4918 Duke Energy 8916 N/A N/A N/A Removed No 2MCR-NI-4918 Duke Energy 37057 N/A N/A N/A Installed No
- 7. Description of Work Re[
Additional Description re
- 8. Tests Conducted:
Hydrostatic Description (Optional):
placed Component/Part/Appurtenance placed snubber on hanger 2MCR-NI-49 18 Pneumatic f-Nominal Operation Pressure F Exempt Other f-Pressure PS.J Test Ternp.
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
I 1/2 in. (norninal)
System Class:
ASME Class 2 Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
MCFD-2562-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCR-NI-4918 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2N1-214-001, PIP# M-11-01899 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XL.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
'$&X'a,#-
Date March 21
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
/'"'
/(
to.
2
( and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither th,Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind in ti Owner'snnReport.Frhroe ned "r
arising from d with this inspectio
- JF Swan
- Commissions NC 1524, N-I Inspctor's'Signaturet National Board, State, Province, and Endorsements Date 3 --2-?
n, I
I. Owner
- 2. Plant Duke Energy Carolinas, LI
.526. South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOR.
_PAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI LC Date 3/21/2011 Charlotte, NC, 28201....
Sheet 1
of 2 Station Unit 2 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LILC Name 1923857-75
- 3. Work Performed by Work Order 9 (or Repair/Replacemrent Organization P.O. No., lob No, etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC._2820 1-1006*
N/A Address Expiration Date:.
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name ofManufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-NV-4483 Duke Energy 61257-50 N/A N/A N/A
..Removed No 2MCR-NV-4483 Duke Energy 30800150-031 N/A N/A N/A
_In stalled No
- 7. Description of Work Rep Additional Description re
- 8. Tests Conducted:
Description (Optional):
)laced Component/Part/Appurtenance placed snubber on hanger 2MCR-NV-4483 Pneumatic F-Nominal Operation Pressure F Exempt F Other F Pressure
-PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
3 Weld Isometric Drawing No(s).:
N/A in. (nominal)
System Class: ASME Class2 Flow Diagram No(s).:
MCFD-2554-01.02 Support/Restraint Sketch/Drawing No(s).:
2MCR-NV-4483 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2NV-202-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
-"--Date:March 21 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
,Cormecticut have inspected the components described in this Owner's Report during the period
- ~
2
£'Z/
to 2- Ž -
/
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or nnected with this inspection.
JF Swan Commissions NC 1524, N-I
ýDate 6* I nspector's Signature 7*
National Board, State, Province, and Endorsements
, 20/t/
Date 201.6
I. Owner
- 2. Plant Duke Energy Carolinas, LL
_.526.South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOi LPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 3/21/2011 Charlotte, NC, 28201........1.
Sheet I
of 2 Station Unit 2 Name 12700.Hagers._Ferry Road_Hu.n.tersvill.e, NC 280_78 Address Duke Energy Carolinas, LLC Name 1923857-76
- 3. Work Performed by Work Order # (or Repair/Replacement Organization P 0. No., Job No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC 28201-1006 N/A Address Expiration Date:
- 4. Identification of System ND - Residual Heat Removal
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-ND-6326 Duke Energy 10977 N/A N/A N/A Removed No 2MCA-ND-6326 Duke Energy
- 38037 N/A N/A N/A Installed No.
- 7. Description of Work Rep Additional Description rei
- 8. Tests Conducted:
Hydrostatic "-
Description (Optional):
tlaced Component/Part/Appurtenance placed snubber on hanger 2MCA-ND-6326 Pneumatic F Nominal Operation Pressure F Exempt F" Other F Pressure PSI Test Temp. _
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
1 1/2 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Sheet 2 of 2 System Class:
ASSME Class 2 Flow Diagram No(s).:
MCFD-2561-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCA-ND-6326 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhereon NIS-2 Form:
PIP# M-I 1-0 1899 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 21
,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
.Connecticut have inspected the components described in this Owner's Report during the period
- -t '22.
/
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ownrs Report. Furthermore, neit.thpi he Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro0 r connected with this inspec n.
JF Swan Commissions NC 1524, N-I Dat a Inspector's Signature'!
National Board. State, Province, and Endorsements Dat
,20L6
- 1. Owner
- 2. Plant Duke Energy.Carolinas_, L 526 South Church. Street,..
Address McGuire Nuclear 12700 Haoers Fei FORM NIS-2 OWNER'S REPORT FC REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 Date 4/3/2011 Charlotte, NC,.28201 Sheet 1
of 2
.Station.
Unit 2 Name rry Road, Huntersville, NC 28078 1924239-04
- 3. Work Performed by Address DQuke Energy Carolinas,.LLC.
Name 526 South Church Street,. Charlotte,. NC 282l0-1006 Address Work Order # (or Repair/Replacement Organization P.O. No., lob No., etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System NC - Reactor Coolant
- 5. (a) Applicable Construction Code ASME III (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components 19 71 Edition, Summer and Winter it ion with the 1999 and 200.0 Addenda.
Addenda, N/A Code Case Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2NC I Crosby N56925-00-0003 27 N/A 1974 Renmoved Yes
- 2NC I*
Crosby N56925-00-0009 525 N/A 1978 Installed Yes
- 7. Description of Work RepJaned_ ComponetTart/Appurtenance Additional Description replaced valve 2NC 1.
- 8. Tests Conducted:
Hydrostatic F Pneumatic F Nominal Operation Pressure [7 Exempt F Other F Pressure 2235 PSI Test Temp. "535
'F Description (Optional): testperformedper procedure MP/0/A/7650/076 aga.instork_ order 0 _924575-01 (Class A Walk -Down fo2EOC20)
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
16 in. (nominal)
Weld Isometric Drawing No(s).: MCFI-2NC7 & 53 Sheet 2 of. 2 System1 Class:
ASME-Class-Flow Diagram No(s).:
MCI Support/Restraint Sketch/Drawing, No(s).:
N/A
~D-2561-01.00 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
-. 5#,
Date April 3
,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nort h Carolina and employed by: Hartford Steam Boiler Inspection and Insurance Company of
'Connecticut have inspected the components described in this Owner's Report during the period to
.t./"
_ t/t/"
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthennore, neither the I0ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspecttion "JFSvan h
Commissions.NC 1524, N-1 National Board. State, Province, and Endorsements Date(
2___________W____
K I
CI ziossV CROSBY VALVE 8
GA GE W R ENTH AM, MASS CO M PANY 4.-
FORM NV-i FOR SAFETY AND SAFETY RELIEF VALVES As required by the provisions of the ASME Code Rule*
DATA REPORT Safety and Safety Relief Valves Q.C.-44C I. Manufactured By Crosby Valve & Gage Co.,
43 Kendrick St., Wrentham, MA 02093 Name and Address Model No.
HB-8 6 -Brder No N300580J Contract Date
/25/76ational Board No.
525
- 2. Manufactured For Duke Power Co.,
Charlotte, No. Carolina Order No.
A 33957 Name and Address
- 3. owner Duke Power C,.
, 422 South Church St., Chariotte, North Carolina 28201 Name and Address
- 4. Location of Plant McGuire Nuclear Station Unit, Cowans Ford, North Carolina
- 5. Valve Identification SPARE -
3 Serial No.N 5 6 9 2 5 -OO-00O 9 Drawing No. DS-C-56925 Rev.
C I
Safety Type Orifice Size.
Pipe Size Inlet_1..
_Outlet._.
Inch Inch Inch inch SafetySafety Relief. pilot. power Actuated
- 6. Set pressure (PSIG) 2485 700 F
Rated Temperature Stamped Capacity 420006 lbs./hr.
Sat-.
3 Overpressure_
Blowdown OU100 57' rlf S P.
Hydrostatic Test (PSIC) Inlet 4575 Complete Valve 750
- 7. The material, design. construction and workmanship comply with ASME Code, Section I1I.
Class 1
Fdition 1971,Addenda Date Winter 1972 Case No.
Pressure Containing or Pressure Retaining Components t
- a. Castings Body Bonnet
- b. Bar Stock and Forgings Dellojw K56 3 8 3 0023 Nozzle Disc Insert Spring WashersK56380-30-0084 Adjusting Bolt Spindle K56381-50-0144 Serial No.
Identification N9039 7-33-0009 N90353-44-0123 N90356-41-0042 N90399-35-0009 N90426-36-0024 N90350-17-0.69 N90350-2-0025 N90351-44-01 2
N90354-52-0143 Material Specification Including Type or Grade ASME SA351 Gr.
CF8M ASME SA105 Inconel Alloy 718 ASME SA182 Gr.
F316 Haynes Stellite Alloy No.
6B ASMF SA15 ASTM A193-70 Gr.
B6 ASME SA193 Gr.
B6 F
arli~rr B6B
1.1...
Serial No. or Material Specification Identification Including Type or Grade
- c. Spring K56380-39-0084 NX2761-0088 ASTM A304-76 51B60H
- d. Bolting
- e. Other Parts such as Pilot Components Qonnet Stud 87589 ASTM A193 cr. B7 N
,We certify that the statements made in tbis report are correct.
DateZ
-7 19 '7ý Signed Crosbv Valve & Gage Co.
By Manufact rer
.ertificate of Authorization No.
1878 expires September 30, 1980 CERTIFICATE OF SHOP INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Proince of Mass and eniployed by Factory.
LMutual Svstemq,ý_
_'=o*
cd-
"gs.
/
ave inspected the equipment desciued in z.ib Dja Re:)or on
!9 and state that to the best of my knowledge and belief. the Manufacturer hoi* constructed this equip-ment in accordance with the applicable Subsections of ASME Section III.
By signing this certificate, neither the Inspector nor his emploYer makes an. warranty, ex-pressed or implied. concerning the ecn:prmenr described in this Data Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injur% or property danmage or a loss of any kind arisirg from or connected with this inspection.
Date i__"7,"h--
)
t' 1 Co.,missions (Inspector
.nn B.ad.
- Arkwright-Boston Manufacturers
'lutual Insurance Company Mutual Boiler
& Machinery Division.
I I.;
DUKE POWER COMPANY QUALITY ASSURANCE DEPARTMENT SUPPLIER QUALITY ASSURANCE CERTIFICATION Name of Supplier Crosby Valve & Gage Company Date March 14, 1978 Address of Supplier Plant 43 Kendrick Street Mill Power Order No.
A-33957 Wrentham, Mass, 02093 Duke Item or Req.
No.
Item 1 Spec.
No.
MCS-1205o09-i Rev.
Supplier ID Nos.
N56925-00-0007, N56925-OO-0008. N56925-00-0009 Description of Component(s) or Material(s)
Steel Safety Valves x
Attached Documentation covers all Components/Materials on Mill Power Order.
Attached Documentation covers partial shipment of Components/Materials on Mill Power Order.
The following listed tests, inspections and reports have been completed as required by the speci fication:
X Physical G Chemical Analysis X
Major Repair Records f Charts X
Hydro (Test Pressure - PSIG 2485)
X Personnel Qualifications on Record
- Crosby No.
Design Report N
Stress Report X
Heat Treatment Xj(
Radiographic Test X
Ultrasonic Test X
Magnetic Particle Penetrant Test X.
Repair NOE X
Cleanliness Operating Test N
Performance Curve ASME Data Report X
Dimensional Check N7/5 Deviation Record #
I)
Tested in accordance with Crosby Procedure T-16063 Opyv o
2) 3)
This certifies that the listed Component(s) or Material(s) conform to the requirements of the above referenced Duke Power documents including all codes, standards, test requirements and Quality Assurance requirements invoked therein.
Suppl ier Represenatni e Authiori S i gn,,I.re Title Q.
A.
Supervisor Date
'70_4ý1/
/4-/97c.
(See Instructions)
Form 930.IA / Rev.
3
- 1. Owner
- 2. Plant
.Duke.Energy Carolinas, LI 5.26 South Church Street,.
Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOR.
.?AIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI LC Date 3/16/2011 Charlotte, NC, 28201 n
.Un.-
Sheet I
of 2 rStation Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 1925900-05 Work Order 0 (or Repair/Replacernent Organization P.O. No, lob No., etc.)
- 3. Work Performed by Type Code Symbol Stamp:
Authorization No.:
526. South Church Street,.Char.lotte,.N.C._28.20.-..
1-.0.0.6 N/A Address Expiration Date:
- 4. Identification of System NS - Containment Spray
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped ComponentIntle (esoN)
Name ofManufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-NS-4516 Duke Energy N/A N/A N/A N/A installed
- 7. Description of Work Additional Description
- 8. Tests Conducted:
Hydrostatic Description (Optional):
Replaced Com ponent/Part/A ppurte. ance Installed items 8 (3x3x3/8 angle), 9 (3/8 x 5 x 8 plate), and 10 (3/8 x 3 3/4 x 7 1/16 plate) on hanger 2MCR-NS-4516 per EC101538.
FI Pneumatic F Nominal Operation Pressure r7 Exempt F Other F-Pressure
.PSI Test Temp.
OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
8 in. (nominal)
Weld Isometric Drawing No(s).:
N/A Flow Diagram No(s).:
MCFD-2563-01.00 Support/Restraint Sketch/Drawing No(s).:
2MCR-NS-4516 System Class:
ASME Class 2 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
EC101538 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed 'FL Grass, Quality Assurance Technical Specialist
.,,/
Date.March 16 20 I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
.North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
.to
/-3 Z/
and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective rnefsures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fr onnected with this pection.
JF Swan F",
Commissions :NC 1524, N-I 6/
Inspector's Signature Date
(
National Board, State, Province, and Endorsements 20o//
I. Owner
- 2. Plant DukeEnergy Carolin.as, Lt_
526 South Church Street, Address McGuire Nuc~lear FORM NIS-2 OWNER'S REPORT FOl%
JPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi LQ
Date 3/27/2011 Charlotte, NC,28201..
Sheet 2
of 2 Station Unit 2 N'arne 12700 Hagers Ferr..Ty Road Huntersv ille, NC 28078 Address
- 3. Work Performed by Duke Energy !Carol inas, LLC Narne 5.26. South Church Street, Charlotte, N.C_9820 I-1006 Address 1927185-02 Work Order N (or Repair!Replacement Organization P 0. No., lob NoJ, etc.)
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
- 4. Identification of System WL - Liquid Waste Recycle System
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998_Edition with the 1-999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Code Case Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No)
WL system Duke Energy N/A 76 N/A 1982 Installed Yes 1
1
.1 1:
[
____ I
- 7. Description of Work Additional Description Rep laced Component/PartUAppunrteance
-Replaced disc and yoke on valve 2WL 1302.
- 8. Tests Conducted:
Hydrostatic F Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure 15 PSI Test Temp. amb OF Description (Optional): test performed per procedure PT/2/A/4200/00.C by OPS. This ptipingoi openendedtocontainment and only sees system pressure for accide...
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2WL206 Sheet 2 of 2 System Class: ASME Class 2 Flow Diagram No(s).:
MCI Support/Restraint Sketch/Drawing No(s).:
N/A FD-2565-0 1.00 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCM-1205.01-0246.001 & 002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 27
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
.North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 3
.Z*L/i
.'L to-
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the In ctor nor his employer shiall be liable in any manner for any personal inijury or property damage or a loss of any kind arising from or nnected with this inspection.
JF Swan
/.Commissions NC 1524, N-I
.Inspector's Signature National Board, State, Province, and Endorsements Date 20_fl
- 1. Owner
- 2. Plant FORM NIS-2 OWNER'S REPORT FOR K
'AIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI Duke Energy Carolinas, LLC Date 3/21/2011 526 South Church Street, Charlotte,.NC, 28201 Sheet I
of 2 Address McGuire. Nuclear. Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC. 2.80.78 Address
- 3. Work Performed by Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 2820 1-1006 Address 192919 8-06 1929198-06 Work Order # (or Repair/Replacement Organization P.O No, lob No, etc.)
,*,"a*c
.. t^le....
N/A 1T',I ype: Code S.ymbol Oatml~p; Authorization No.:
Expiration Date:
N/A
- 4. Identification of System NV - Chernical and Volume Control
- 5. (a) Applicable Construction Code ASME Il 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000.Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected.
ASME Code Name of Manufacturer National Other Year Removed, or Stamped ComponentName oManufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCR-NV-5192 Duke Energy N/A N/A N/A N/A Installed No
- 7. Description of Work Re.placed Co m pQoDpertIn
/Pappt ena nce.
Additional Description re
- 8. Tests Conducted:
Hydrostatic r Description (Optional):
placed bolting material in pipe clamp on hanger 2MCR-NV-5192 Pneumatic F-Nominal Operation Pressure Fl Exempt FW Other F Pressure PSI Test Temp. _
I'
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:N/
System Class:
ASME.C ass_2 Flow Diagram No(s).:
.N/A Support/Restraint Sketch/Drawing No(s).:
2MCR-NV-5 192 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2NV201-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 21
, 2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by, Hartford Steam Boiler Inspection and Insurance Company of
.Connecticut have inspected the components described in this Owner's Report during the period
-S-
/
-/-.
to.
" Z. 2"
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the In ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspectin.
JF Swan Commissions ýNC 1524, N-I Inspector's Signature National Board, State, Province, and Endorsements IDate Dat
-2 L
,20//'
I. Owner
- 2. Plant Duke Energy Carolinas, Lt 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOR K AIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASRIE Code Section X I LC Date 3/20/2011 Charlotte, NC,-282.01 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road,. Hunt.ersville, NC 28078 Address Duke Energy Carolinas, LL.C Name 01930670-89
- 3. Work Performed by Work Order # (or Repair/Replacement Organization P.O. No., lob No.. etc.)
Type Code Symbol Stamp:
N/A Authorization No.:
N/A 4.
5.
6.
526 South Church Street, Charlotte, NC 28201-1006..
Address Expiration Date:
N/A Identification of System NV - Chemical and Volume Control (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the.1999 and 200.0 Addenda (c) Applicable Section Xl Code Case(s) N/A Identifittcatin nf C'nmn"ctnentt Corrected, ASME Code Name of' Manufacturer National Other Year Removed, or Stamped Component Name of N'lanttrer Serial No.
Board No.
Identification Built Installed (Yes or No) 2MCA-NV-5405 Duke Energy 3565 N/A N/A N/A Removed No 2MCA-NV-5405 Duke Energy 30700004/010 N/A N/A N/A Installed No
- 7. Description of Work Rep Additional Description re
- 8. Tests Conducted:
Hydrostatic Description (Optional):
placed Component/Part/Appurtenance placed snubber on hanger 2MCA-NV-5405 Pneumatic "-
Nominal Operation Pressure F Exempt F" Other F-Pressure PSI Test Temp. _
(
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2.
of 2 Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
N/A System Class: ASNE Class 2 Flow Diagram No(s).:
MCFD-2554-03.01 Support/Restraint Sketch/Drawing No(s).:
2MCA-NV-5405 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2*NV-_53-0001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 20
")011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Confpany of Connecticut have inspected the components described in this Owner's Report during the period
/
/
to 3-2.- 2 -2/1
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspection.
JF Swanot
-Commissions NC1524, N-I
- Inspector's Signature_..
/
National Board, State. Province, and Endorsements
-j 2--2--
20/
- 1. Owner
- 2. Plant FORM NIS-2 OWNER'S REPORT FOi
£PAIR/REPLACEMENT ACTIVITY As Required hy the Provisions of rhe AS ME Code Section XI Duke Energy Carolinas, LLC Date 4/3/2011 526 South Church Street, Charlotte, NC, 28201 Sheet 1
of 2 Address McGuire Nuclear Station Unit 2 Name 12700 Hagers Ferry Road, Huntersvit!e_.NC 28Q78 Address
- 3. Work Performed by Duke Energy Carolinas_,_L.C Name 526 South.Chturch Street, Charlotte,.NC.28201-1.00_6 Address 1932306-02 Work Order # (or Repair/Replacement Organization P.O. No., lob No, etc )
Type Code Symbol Stamp:
N/A Authorization No.:
N/A Expiration Date:
N/A
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A (b) Applicable Edition of Section X I used for Repair/Replacement Activity 1998 Editjon with the 1999 and 2..00.0 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Corn onents Code Case Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2NV248 Kerotest ATH7-4 38542 N/A 1991 Installed Yes
- 7. Description of Work Additional Description Replaced Component/Part/Appurtenance replaced disc on valve 2NV248.
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
Pneumatic F-Nominal Operation Pressure F..
Exempt F Other F-Pressure PSI Test Temp. __
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASIME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Sheet 2 of 2 Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2NV294 System Class: ASME Class 2 Flow Diagram No(s).:
MCFD-2554-03-.OO Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCM 1205.01-0042.001, MCSRD-2NV350 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date April 3
, 20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
- Connecticut have inspected the components described in this Owner's Report during the period
-t to
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither t Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this
.1sectio JF Swan J
-/
Commissions NC 1524, N-I Inspctors Sinatr'l--
- lop, ational Board, State, Province, and Endorsements Date20L
- 1. Owner
- 2. Plant.
Duke-Energy Carolinas, LL
.52.6._South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO, 7PAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 4/3/2011 Charlotte,.NC, 28201 Sheet I
of 2 Station Unit 2
- 3. Work Performed by Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Name 526 South Church Street, Charlotte, NC 28201-1006 Address 1933815-07 Work Order N (or Repair/Replacement Organizaton P1 No., lob No., etc.)
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
- 4. Identification of System NI - Safety Injection
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Sumnmer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Namie of' Manufacturer National Other Year Removed, or Stamped CoN eponent of tvla cturer Serial No.
Board No.
Identification Built Installed (Yes or No) 2N171 Walworth A0148 209 N/A 1974 Installed Yes
- 7. Description of Work Replaced Component/Part/Appurtenance Additional Description replaced disc and bonnet nuts on valve 2N17 1.
- 8. Tests Conducted:
Hydrostatic r Pneumatic r Nominal Operation Pressure F Exempt I Other F Pressure 2235 PSI Test Temp. 535 OF Description (Optional):
test performed per procedure MP/0/A/7650/076_against work order 0 924575-01 _(Class A Walk -Down for 2EOC20)
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 9.. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
10 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2NV254 Sheet 2 of 2 System Class: ASME Class I Flow Diagram No(s).:
MCFD-2562-02.00 Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date April 3 20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
,North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
- Connecticut have inspected the components described in this Owner's Report during the period S.to-
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and.corrective measures described in this Owner's eport. Furthermore, neither the Insp or nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o fonnected with this inspection.
JF Swan Commissions,NC 1524, N-1 I
tor's r
Nitional Board, State, Province, and Endorsements Date q
20
- 1. Owner
- 2. Plant Duke Energy Carolinas, LL
.526._South Church Street,,
Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO.
.EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- C Date 4/3/2011 Charlotte,. NC_,..2820] 1......
Sheet I
of 2 Station Name 1.2700 Hagers.Ferry. Road, Huuntersville._NC 28078 Address Duke Energy Carolinas, LLC Name Unit 2 1972897-02 Work Order N (or Repair/Replacement Organization P.O. No, lob No, etc.)
- 3. Work Performed by kr/A Type Code Symbol Stamp:
Authorization No.:
N/A 526 South Church Street, Charlotte, NC 28.201-10.066.
Da:N/A Address Expiration Date:
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity
- 1998 Edition with.the 1999. and.2000.Ad0denda (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected.
ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Installed (Yes or NO)
Name of Manufacturer Serial No.
Board No.
Identification Built NV Piping Duke Energy N/A 80 N/A 1982 Installed Yes
- 7. Description of Work Ad Additional Description mt
- 8. Tests Conducted:
Hydrostatic F Description (Optional):
d New Compo_.e(nt/Part/Appurtienance/ýWeld ade.weld repair on weld NV2FW 183-28 Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure 2514 PSI Test Temp. 90.6 OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the AS ME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2NV183 Sheet 2 of 2 System Class:
ASME C-lass 2 Flow Diagram No(s).:
MCI Support/Restraint Sketch/Drawing No(s).:
N/A FD-2554-01.01 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Z/
Date April 3
,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fromor connected with this inspect JF Swanl 0-
-j2-I
.n,,.-.
Commissions NC 1524, N-l Inspector'sonal Board, State Province, and Endorsements Date0
- //-.S
, 20.__
- 1. Owner
- 2. Plant Duke Energy Carolinas, LI 526 South Church Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FO,
.EPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Cede Section XI LC Date 4/3/2011 Charlotte, NC, 28201 Sheet I
of 2
-Station Unit 2 Namne 12700 Hagers Ferry Road, Huuntersville, NC 28078 1973388-05 Address Work Order 9 (or Repair/Replacement Organization P.O No lob No., etc
- 3. Work Performed by Duke Energy Carolinas, LLC Tvpe Code Symbol Stamp:
NiA Name Authorization No.:
N/A 526 South Church Street, Charlotte,_NC_.8_20 1-1006 N/A Address Expiration Date:
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Y'ear Removed, or Stamped Component Name of ManUfacturer Serial No.
Board No.
Identification Built Installed (Yes or No)
NV Piping Duke Energy N/A 80 N/A 1982 Installed Yes
- 7. Description of Work Re Additional Description W
- 8. Tests Conducted:
Description (Optional):
placed Component/Part/Appurtenance elds NV2FW293-12, 38, and 39 were cut out and remade Pneumatic F Nominal Operation Pressure Exempt F Other F Pressure 2500 PSI Test Temp. 90.6 OF
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2NV293 Sheet 2 of 2 System Class:
ASME.Cl1a.ss.2 Flow Diagram No(s).:
MCF Support/Restraint Sketch/Drawing No(s).:
N/A D-2554-03.00 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify, that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist
-. :-x Date April 3 20.1L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
- North Carolina and employed by !Hartford Steam Boiler Inspection and Insurance Company of
ýConnecticut have inspected the components described in this Owner's Report during the period
-to V-5; -
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the lpector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fr*om oconnected with this inspection.
Swan Commissions NC1524, N-I
/ Inspector's Signature 11/National Board, State, Province, and Endorsements Date
°
),
20 /
- 1. Owner
- 2. Plant Duke.Energy Carolinas, LL 526 South Church. Street, Address McGuire Nuclear FORM NIS-2 OWNER'S REPORT FOR PAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI C
Date 4/19/2011 Charlotte, NC, 28201 Sheet I
of 2 Station Unit 2 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 Address Duke Energy Carolinas, LLC Narne 1974289-02
- 3. Work Performed by Work Order fP (or Repair/Replacement Organization P 0. No lob No., etc Type Code Symbol Stamp:
N/A Authorization No.:
N/A 526 South Church Street, Charlotte, NC 28201-1006 N/A Address Expiration Date:
- 4. Identification of System NV - Chemical and Volume Control
- 5. (a) Applicable Construction Code ASME II1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 19918 Edition with the. 1999 and 200...Adden~da.
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name otMantacturer Serial No.
Board No.
Identification Built Installed (Yes or No)
.NV Piping Duke Energy N/A 80 N/A 1982 Installed Yes
- 7. Description of Work Additional Description Replaced Component/Part/Appurtenance Rep!aced bolting material in flange down stream of valve 2NV810.
- 8. Tests Conducted:
Hydrostatic F Pneumatic F Nominal Operation Pressure F' Exempt F Other F Pressure 2235 PSI Test Temp. 535 OF Description (Optional): test performed per procedure MP/0/A/07650/076 on w/o 1924575 (Class A walk-down for 2EOC20)
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
- 9. Remarks (Should Include the Following Information, as Applicable):
Component Line Size:
1 1/2 in. (nominal)
Weld Isometric Drawing No(s).:
MCFI-2NV275 Sheet 2 of 2 System Class:
ASME_Class I Flow Diagram No(s).:
MCFD-2554-0 1.00 Support/Restraint Sketch/Drawing No(s).:
N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:
MCSRD-2NV-206-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date April 19
- , 2011 Owner or Owner's Designee, Tttle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by.Hartford Steam Boiler Inspection and Insurance Company of
- .Connecticut have inspected the components described in this Owner's Report during the period 2-.6 1
to I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthemore, neither the Ins ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from /connected with this inspection.
JF Swan 10 Cnmmissions NBI 1473-NC1524, N-I Inspector's Signature Date/
National Board, State, Province, and Endorsements 2)0 Y
6.0 Pressure Testina Second Period-Third JO-Year Interval There is (1) Class I (Category B-P) pressure test zone that requires pressure testing each refueling outage. Table 6-1 shows a completion status of the Class I (Category B-P) pressure test zone conducted during refueling cycle EOC 20. There was no through-wall leakage observed during this pressure test.
Table 6-1 Detailed Class I Listing EOC20 Zone Completion EOC20 VT-2 Number Boundary Dwg Status Examination Date Code Cases Used 2NC-001L-A MC-ISIL-2553-01.00 Complete 04/01/2011 None MC-ISIL-2553-02.00 MC-ISIL-2553-02.01 MC-ISIL-2554-01.00 MC-ISIL-2554-01.01 MC-ISIL-2554-01.02 MC-ISIL-2561-01.00 MC-ISIL-2562-01.00 MC-ISIL-2562-02.00 MC-ISIL-2562-02.01 MC-ISIL-2562-03.00 I____
MC-ISIL-2562-03.01 I
I There are (66) Risk Informed Segments (Category R-A) that are required to receive a pressure test each refueling cycle. Table 6-2 shows a completion status of the (66)
Risk Informed Segments pressure tested during refueling cycle EOC 20. There was no through-wall leakage observed during these pressure tests.
Table 6-2 Detailed Risk Informed Pressure Test Listing EOC20 Zone Segment Completion EOC20 VT-2 Number Boundary Dwp Number Status Examination Date I
2NC-001L-A MC-ISIL-2553-01.00 NC-18 Complete 04/01/2011 2
MC-ISIL-2553-02.00 NC-19 3
MC-ISIL-2554-01.00 NC-20 4
MC-ISIL-2554-01.01 NC-21 5
MC-ISIL-2562-01.00 NC-23 6
NC-086 7
NC-89 8
NC-90 9
NC-054 10 1
NC-055 I
EOC 20 / Outage 5 McGuire Unit 2 Section 6 - Third Ten-Year Interval Page 1 of 6 Revision 0 May 25, 2011
Table 6-2 Detailed Risk Informed Pressure Test Listing EOC20 Zone Segment Completion EOC20 VT-2 Number Boundary Dwg Number Status Examination Date 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 2NC-0I1L-A (Continued)
NC-056 NV-033A NV-033B NV-034A NV-034B NV-037 NV-038 NV-041A NV-041B NV-042A NV-042B NV-030A NV-030B NV-032A NV-032B NV-035 NV-036 NV-039A NV-039B NV-040A NV-040B NI-068 NI-069 NI-070 NI-071 2RI-001 L-B MC-ISIL-2554-01.00 MC-ISIL-2554-01.01 MC-ISIL-2554-01.02 MC-ISIL-2554-01.03 MC-ISIL-2554-03.00 MC-ISIL-2554-03.01 MC-ISIL-2561-01.00 MC-ISIL-2562-01.00 MC-ISIL-2562-03.00 NI-063B ND-008C ND-009C NV-002AB NV-002C NV-002D NV-011A NV-019B NV-019C NV-019D NV-019E NV-019AA NV-019AB Complete 04/02/2011 U
J A
EOC 20/ Outage 5 McGuire Unit 2 Section 6 - Third Ten-Year Interval Page 2 of 6 Revision 0 May 25, 2011
Table 6-2 Detailed Risk Informed Pressure Test IUstng EOC20 Zone Segment Completion EOC20 VT-2 Number Boundary Dwg Number Status Examination Date 49 2RI-001 L-B NV-019AD 50 (Continued)
NV-020AA 51 NV-020AB 52 NV-020AD 53 NV-020AE 54 NV-021A 55 NV-021B 56 NV026 57 NV027 58 NV-028 59 NV-029 60 NV-080A 61 NV-080B 62 NV-084A 63 NV-084B 64 NV-084C 65 NV-108A 66 1
NV-109 EOC 20 / Outage 5 McGuire Unit 2 Section 6 - Third Ten-Year Interval Page 3 of 6 Revision 0 May 25, 2011
There are (35) Class 2 (Category C-H) pressure test zones that require pressure testing once each Inspection Period. Table 6-3 shows a completion status of the (35) Class 2 (Category C-H) pressure tests zones that require pressure testing for the Second Period of the Third Ten-Year Interval (from 03/01/07 through 07/15/11). There was no through-wall leakage observed during these pressure tests.
Table 6-3 Detailed Class 2 Second Period Listing VT-2 Code Examination Cases Zone Number Boundary Dwg Completion Status Date Used 1
2BB-040L-B MC-ISIL-2580-01.00 Incomplete N/A 2
2BB-074L-B MC-ISIL-2572-03.00 Complete 10/0912009 None MC-ISIL-2580-01.00 MC-ISIL-2584-01.00 3
2CA-040L-B MC-ISIL-2592-01.00 Incomplete N/A 4
2CA-043L-B MC-ISIL-2584-01.00 Incomplete N/A MC-ISIL-2591-01.01 MC-ISIL-2592-01.00 MC-ISIL-2617-01.00 5
2FW-007L-B MC-ISIL-2554-03.00 Complete 11/10/2010 None MC-ISIL-2554-03.01 MC-ISIL-2561-01.00 MC-ISIL-2562-03.00 MC-ISIL-2563-01.00 MC-ISIL-2571 -01.00 6
2NC-001L-A MC-ISIL-2553-01.00 Complete 04/10/2008 None MC-ISIL-2553-02.00 MC-ISIL-2554-01.00 MC-ISIL-2554-01.01 7
2ND-009L-B MC-ISIL-2554-01.02 Incomplete N/A MC-ISIL-2561-01.00 MC-ISIL-2562-03.00 MC-ISIL-2562-03.01 MC-ISIL-2563-01.00 MC-ISIL-2571-01.00 MC-ISIL-2572-01.00 EOC 20 / Outage 5 McGuire Unit 2 Section 6 - Third Ten-Year Interval Page 4 of 6 Revision 0 May 25, 2011
Table 6-3 Detailed Class 2 Second Period Listin g
VT-2 Code Zone Number Boundary Dwg Completion Status Examination Cases I
Date Used 8
2ND-010L-B MC-ISIL-2561-01.00 Incomplete NIA MC-ISIL-2562-03.01 MC-ISIL-2563-01.00 9
2NI-012L-B MC-ISIL-2562-02.00 Complete 04/08/2008 None MC-ISIL-2572-01.01 10 2NI-013L-B MC-ISIL-2562-02.01 Complete 04108/2008 None MC-ISIL-2572-01.01 11 2NI-014L-B MC-ISIL-2562-02.01 Complete 04/03/2008 None MC-ISIL-2562-03.00 12 2NI-015L-B MC-ISIL-2562-03.00 Incomplete N/A 13 2NI-016L-B MC-ISIL-2562-03.00 Complete 11/01/2010 None 14 2NI-017L-B MC-ISIL-2562-03.00 Incomplete N/A MC-ISIL-2562-03.01 15 2NI-01 8L-B MC-ISIL-2562-03.01 Complete 03104/2011 None 16 2NI-060L-B MC-ISIL-2562-03.00 Complete 10/05/2009 None 17 2NI-061 L-B MC*-ISIL-2562-01.00W Complete 02/25/2011 None 18 2NI-062L-B MC-ISIL-2562-01.00 Incomplete N/A 19 2NM-026L-B MC-ISIL-2572-01.01 Complete 10/09/2009 None 20 2NM-027L-B MC-ISIL-2572-03.00 Incomplete N/A 21 2NS-019L-B MC-ISIL-2563-01.00 Complete 01/1412011 None 22 2NS-020L-B MC-ISIL-2563-01.00 Complete 12/02/2010 None 23 2NV-003L-B MC-ISIL-2554-01.00 Incomplete N/A MC-ISIL-2554-01.01 MC-ISIL-2554-01.02 MC-ISIL-2554-01.03 24 2NV-004L-B MC-ISIL-1 554-05.00 Incomplete N/A MC-ISIL-2554-01.00 MC-ISIL-2554-01.01 MC-ISIL-2554-01.02 MC-ISIL-2554-02.00 MC-ISIL-2554-02.01 EOC 20 / Outage 5 McGuire Unit 2 Section 6 - Third Ten-Year Interval Page 5 of 6 Revision 0 May 25, 2011
Table 6-3 Detailed Class 2 Second Period Listing VT-2 Code Zone Number Boundary Dwg Completion Status Examination Cases Date Used 24 2NV-004L-B MC-ISIL-2554-03.00 Incomplete N/A MC-ISIL-2554-03.01 MC-ISIL-2561-01.00 MC-ISIL-2562-01.00 MC-ISIL-2562-03.00 25 2NV-005L-B MC-ISIL-2554-01.02 Incomplete N/A 26 2NV-006L-B MC-ISIL-2554-03.00 Complete 02/02/2011 None 27 2NV-008L-B MC-ISIL-2554-01.02 Complete 10/4/2009 None 28 2NV-011L-B MC-ISIL-2554-03.01 Complete 10/18/2010 N'ri" 29 2RN-044L-B MC-ISIL-2574-04.00 Incomplete N/A 30 2RV-048L-B MC-ISIL-2604-03.00 Complete 08/30/2010 None 31 2SA-047L-B MC-ISIL-2593-01.02 Incomplete N/A 32 2SM-040L-B MC-ISIL-2591-01.01 Incomplete N/A MC-ISIL-2593-01.00 MC-ISIL-2593-01.03 33 2SM-045L-B MC-ISIL-2593-01.00 Complete 09/20/2010 None MC-ISIL-2593-01.02 MC-ISIL-2593-01.03 34 2SM-046L-B MC-ISIL-2593-01.00 Complete 09/20/2010 None MC-ISIL-2593-01.03 35 2YA-063L-B MC-ISIL-2617-01.00 Incomplete N/A Section 6 Prepared By:
Date:
Section 6 Revirwed By:
Dae:
(.
(,
"N EOC 20 / Outage 5 McGuire Unit 2 Section 6 - Third Ten-Year Interval Page 6 of 6 Revision 0 May 25, 2011