Zlev, Tracey From:
Sent:
To:
Subject:
Attachments:
Burritt, Arthur C2.*
Thursday, April 29, 2010 5:17 PM OHara, Timothy; Conte, Richard; Gray, Harold; Balian, Harry; Cline, 'Leonard; DeBoer, Joseph; Douglas, Christopher; Ennis, Rick; Johnson, Jonathan; Kern, Ludwig; Miller, Ed; Moore, Ross; Patel, Amar; Raymond, William; Schroeder, Daniel; Turilin, Andrey; Welling, Blake Branch 3 Status 4/29/10 B3-Status 4-29-10doc See attached The following are the remaining open AFW inspection questions as of a few days-ago Verify hydro/pressure test is code compliant - O'Hara, determined approach was acceptable, received test records but still needs to verify test results. PSEG will also provide the leak check procedure by 4/27 am.
Smart samples o
Verify repairs to the control air system elbow that was replaced (how will PSEG certify the repair) -
O'Hara, PSEG adding more detail to description of document, to provide by 4/27 PM o
Verify control air extent of condition - O'Hara o
Backfill procedure reviews to verify coating and backfill cure times - O'Hara, PSEG to provide by 4/27 pm o
Verify control air clamping material - O'Hara, PSEG to provide supporting document 4127 am o
AFW pipe weld records - O'Hara, PSEG to assess status'of documents by 4/27 pm Design records for as installed AFW piping on Unit 1 & 2 not found h*Mnewm n In tft usrexd was fetww In accordance wfth the rJo~e Einmpiions 171S~
IMM"M-d A-tc )03 1
p t 0
Y Outside of Scope BRANCH 3 DAILY STATUS 4/29/10 4
Highlighted items were discussed at DRPIDRS Coordination meeting T.
BOLD items are new Outside OT Scope W,,,,
Coerae7Da X>O Af666,7-
'AL2=2of3>O.11L:
AL3=IX>io.J7N3 AFW follow-up issues Verify hydro/pressure test is code compliant - O'Hara, determined approach was acceptable, received test records but still needs to verify test results. PSEG will also provide'the leak check procedure 4127 am.
Evaluate the 50.59 for AFW modifications - Scroeder reviewed no significant technical concerns or Issues Smart samples o
Verify repairs to the control air system elbow that was replaced (how will PSEG certify the repair) - O'Hara, PSEG adding more detail to description of document, to provide by 4127 PM o
Verify control air extent of condition - O'Hara o
Backfill procedure reviews to verify coating and backfill cure times - O'Hara, PSEG to provide by 4/27 pm o
Verify control air clamping material - O'Hara, PSEG to provide supporting document 4/27 am o
AFW pipe weld records - O'Hara, PSEG to assess status of documents by 4/27 pm Degraded Equipment Design records for as installed AFW piping on Unit 1 & 2 not found Outside of Scope
Outside of Scope A
U*nit 2 AFW Testinq - PSEG determined that they did not perform ASME code required pressure drop test for the buried sections of the S22 and 24 headers.
9 Confirm the PSEG risk assessment to delay AFW testing for 1 year is reasonable - Cahill, complete, no concerns Evaluate if performing a risk assessment to meet Technical Specification 4.0.5 is appropriate if a test was never performed verses missed - Conte/Ennis - discussions ongoing, no apparent ongoing compliance issues.
Operability, Initial assessment Unit 2 was that it is in better condition based on newer piping; 1994 inspection that identified intact coating; and ISI code gives more allowance to an operating unit (can take credit for up to 90% of the yield Stress).
Evaluate the Unit 2 AFW extent of condition operability assessment - Schroeder no significant technical issues or concerns 4
Confirm the finite element analysis for the Unit 1 as found condition is acceptable including the use of appropriate methods and assumptions - Gray, O'Hara, and HQ reviewed, no significant technical issues or concerns Outside of Scope
~A0.0onavi iteMS Ulu L!Status Board Items:
Salem 1, AFW buried piping generic communications Outside of Scope t