Pu-Plant Maintenance Shop (Room, 116)

During productionf this room contained one glovebox used for re-building contaminated *quipment.

The major source of contamination in this area was the glovebox exhaust duct and solvent extraction exhaust'duct, that ran, through the overhead of this room.

We had some leakage from these two systems.due to condensate build up in-side'these ducts.

After removal of these systems, we removed some piping and supply duct that had been dripped on by this condensate, and removed the floor coating.

We blasted the wall and floor before final release surveys were started.

"We used a Ludlum 2220 with a Ludlum 43-17 low energy gamma probe to survey all cracks'and seams.

A Ludlum 2220 with a Ludlum 43-68, 43-4, or 43-27 was used with P-10 gas for all alpha release surveys.

All smears were taken on Whatman smear paper and counted in a Hewlett

-Packard 5560 A (low background) automatic sample counter.

W. A. Rogers

Pu PLANT RELEASE SURVEY PLAN

1. -For initial decontamination all surfaces will be scanned with an
  • Eberline PRM-6 with a Radeco alpha scintillation probe.

Back-,.'-

ground will be maintained at less than 100 CPM(200 dpm).

All areas greater than twice background will be marked and reading will be taken with a release survey instrument to document "cont-,

,amination levels and random large area smears will be taken.

2. After these initial areas are decontaminated, all floor
surfaces, and the base of each wall will be completely surveyed with a digital readout release instrument and a Ludlum. large area gas proportional alpha detector and random smear samples will be

, taken.,Release instrumentation shall have a minimum detectable level of at least 50 dpm/100 cm2.

3.

All hot spots greater than or equal to 100 dpm/100 cm 2 ident-ified will be decontaminated.

4.

A random survey with a release instrument will be taken on the walls and ceiling to try to identify any other problem areas.

5.

If no problems are identified, each room will be gridded off into approximately 2 meter on a side square on the walls and floor and five readings will be taken in each grid.

Readings shall be taken in the center and at the midpoint from the center to each corner.

6. Each ceiling has closely spaced rafters that will not be easily divided into 2 meter squares.

Because of this, we will take readings on the bottom of each rafter at 2 meter inter-vals and one reading centered on the ceiling between rafters.

Readings on each rafter will be staggered one meter.

7. These release readings will be documented on a map that is drawn to approximately scale measurements in meters.
8. Data provided on each map:
1. Survey block numbers, identifiable on a scale drawings.
a. room or area name or number.
b. surface surveyed.
c. type of measurement and units.
2.

Name of surveyor taking measurements, date of survey, and location.

r. q

'ta W

3.

Type, model number, calibration data, sensitivity' limit, background, and source response of instruments used in'......

-survey.

4.

When a block surveyed is below the sensitivity of the instru-ment,-the fact that such a measurement was made should be

.included as significant data,

9.

All release survey smears will be taken on Whatman smear paper and counted in the automatic sample counters.

Each smear will cover approximately 100 cm2.

10. There'will be at least 30 survey.blocks in each area to be released.

11." Piping and ductwork will be surveyed on all accessable sides at 2 meter intervals.

If more than one line is running parallel in.'

'a pipe rack, readings shall be staggered at one meter intervals.

12.'All readings taken that only cover part of a probe area will be corrected to dpm/100 cm2.

13.

No survey block will measure less than one meter on a si 4..

' *. -:14. NO survey block will measure more than 3 meters on a side.:.-J.-,.

iI

15. All portable release survey instruments will be calibrated quarterly and all instruments in use will be source checked daily.

Table I-I.

Acceptable surface contamination levels Nuclides' Average Maximum U-nat, 1-235, U-238, and associated decay products Transuranics, Ra-226, Ra-228, Th-230, Th-228, Pa-231, Ac-227, 1-125, 1-129 Th-nat, Th-232, Sr-90 Ra-223, Ra-224, U-232, 1-126.

1-131, 1-133 Beta-gamma emitters (nuclides with decay modes other than alpha emission or spontaneous fission) except Sr-90 and other noted above.

5,000 dpm a/1011 cm2 100 dpm/100 cm2 1,000 dpm/lO00 cmz S,000 dpm 8y/IO0 cmI IS,000 dlpm t1/lI ln cm2 3111) dpln/ 1)11) cn -

3,000 dpm/tlO cm 2 15,000O dpm f-1/l00 cm'

~RemovabIe 1,000) d1vm (i/100 cm' 20 dpm/IOU cm'2 200 dpm/l100 cm?

1,000 dpm By/lOO cm2 I-a 0Where surface contamination by both alpha-and beta-gamma-emitting nuclides exists, the limits established for alpha-and beta-gamma-emitting nuclides should apply independently.

bAs used in this table, dpm (disintegrations per minutel means the rate of emission by rndloactive material as determined by correcting the counts per minute observed by an appropriate detector for background, efficiency, and geometric factors associated with the instrumentation.

CMeasurements of average contaminant should not he avoraged over more than I square meter.

I or Objects of less surface area. the average should be derived for each such object.

d.rhe maximum contamination level applies to an area of not more than 100 cm'.

The amount of removable radioactive material per 100 cm2 of surface area should he determined by wiping that area with dry filter or soft absorbent paper, applying moderate pressure, and assessing the amount of radioactive material on the wipe with an appropriate instrument of known efficiency.

When removable contamination on objects of less surface area is..

determined, the pertinent levels should be reduced proportionally and the entire surface should he wiped.

fThe average and maximum radiation levels associated with surface contamination resulting from beta-gamma emitters should not exceed 0.2 mrad/hr at I cm and 1.0 mrad/hr at I cm, respectively, measured through not more than 7 milligrams per square centimeter of total absorber.