John Richmond From:

Sent:

To:

Cc:

Subject:

Attachments:

John Richmond Tuesday, September 09, 2008 4:55 PM David Pelton Richard Conte Oyster Creek LR Outage Commitments Inspection OC Priority Inspection Itemsrev-3.doc Dave, did we agree on 1 PM tomorrow (Wed)?

To facilitate tomorrow's discussion on OC drywell inspection, I've attached my DRAFT inspection task list. The inspection plan has not yet been written or approved.

As a remember, we've been directed to retain all documents & records regarding OC LR, in case a Hearing File is re-opened. That includes e-mails and attachments.

Thanks John Richmond 610-337-5220 1

Received: from R1 CLSTRO1.nrc.gov ([148.184.99.7]) by RI MS01.nrc.gov

([148.184.99.10]) with mapi; Tue, 9 Sep 2008 16:55:08 -0400 Content-Type: application/ms-tnef; name="winmail.dat" Content-Transfer-Encoding: binary From: John Richmond <John.Richmond@nrc.gov>

To: David Pelton <David.Pelton@nrc.gov>

CC: Richard Conte <Richard.Conte@nrc.gov>

Date: Tue, 9 Sep 2008 16:55:06 -0400

Subject:

Oyster Creek LR Outage Commitments Inspection Thread-Topic: Oyster Creek LR Outage Commitments Inspection Thread-Index: AckSvIbOF8eNQa/LQkO5BySlqKnIDQ==

Message-ID: <2856BC46F6A308418F033D973BBOEE72841EADAC12@R1CLSTR01.nrc.gov>

Accept-Language: en-US Content-Language: en-US X-MS-Has-Attach: yes X-MS-Exchange-Organization-SCL: -1 X-MS-TNEF-Correlator:

<2856BC46F6A308418F033D973BBOEE72841 EADAC1 2@R1!CLSTRO1.nrc.gov>

MIME-Version: 1.0

Oyster Creek Outage Inspection License Renewal Commitments - IP 71003 Drywell Shell Thickness Verifications Lower Drywell Shell Internal UT (at Sand Bed Region elevations) 19 Locations inside drywell [IS-328227-004, 3.2.2]

7x7 arrays over a 6"x6" area, and 1x7 arrays, on 1" increments 29 Oct Day Shift, R2096031 [date confirmed, by NDE]

Commitment 27, Item (1 & 21)

Lower Drywell Shell External UT (in Sand Bed Bays) 106 UT readings, in'the 10 bays (2-shift, 24-hr activities) [IS-328227-004, 3.2.3]

Access through 20" manway (tunnel)

Commitment 27, Item (9,14, & 21)

Bay 1 30 Oct

?? [critical bay, based on previous inspection]

Bay 3 30 Oct Bay 5 27 Oct Bay 7 29 Oct Bay 9 28 Oct Bay 11 28 Oct

?? [critical bay, based on previous inspection]

Bay 13 28 Oct

?? [critical bay, based on previous inspection]

Bay 15 29 Oct Bay17 3

Nov Bay 19 30 Oct Upper-Drywell Shell UT at Elev 71' (knuckle region)

Transition from 2.625" plate to 0.640(u plate [IS-328227-004, 3.2.8]

4 locations using a dynamic scan of a 6"x6" area 1 Nov 1700, R2096037 Commitment 27, Item (11)

Lower Drywell Shell UT at Elev 23' (bottom to middle spherical plates)

Transition from 0.770" plate to 1.154" plate [IS-328227-004, 3.2.7]

4 locations using a dynamic scan of a 6"x6" area Does NOT appear to be scoped into outage

[29 Oct 0600, C2017059 (one-time inspection of 4 butt welds)]

Commitment 27, Item (10)

Upper Drywell Shell UT at Various Elevations 9 locations using a 7x7 array, at elev. 87', 60', 51', and 50' [IS-328227-004, 3.2.1]

Commitment 27, Item (7)

Drywell Floor Inspection Access Trenches UT & VT in Bay 5 & Bay 17 Trenches [IS-328227-004, 3.2.6]

Remove & reinstall lower 6" of grout at bottom of Bay 5 trench Inspect caulk sealant (trench edge where concrete meets shell)

Verify no water accumulation 29 Oct 2100, R2117387 Commitment 27, Item (5,16, & 20)

Oyster Creek Outage Inspection License Renewal Commitments - IP 71003 Drywell Interior Service Level I Coating Inspect shell coating inside drywell 29 Oct 0500, R2096685 Commitment 33, Item (1)

Drywell Exterior Service Level II Coating in Sand Bed Bays VT epoxy coating in each bay (2-shift, 24-hr activities) [IS-328227-004, 3.2.4]

Commitment 27, Item (4 & 21)

Commitment 33 Bay.

4 Nov Bay 3 28 Oct Bay 5 2 Nov Bay 7 29 Oct Bay 9 28 Oct Bay 11 28 Oct Bay 13 28 Oct Bay 15 29 Oct Bay 17 2 Nov Bay 19 28 Oct Rx Cavity Concrete Trough Drain Camera Inspection of Rx cavity drain line for blockage 29 Oct 0300,- R2095857 Commitment 27, Item (13)

[how many drain lines??]

Rx Cavity Seal Leakage Trough Drains Daily leakage check R2102695 Commitment 27, Item (3)

[how many drain lines??]

Sand Bed Region Drains (5 drain lines)

Daily leakage check R2102695 Commitment 27, Item (3)

Moisture Barrier Seal between Sand Bed Region Concrete and Embedded Drywell Shell Inspect seal at junction between concrete and shell [IS-328227-004, 3.2.4.1.4]

?? Oct, ??

Commitment 27, Item (3,12, & 21)

Moisture Barrief between Drywell Shell and Concrete Floor Curb inside Drywell Inspect moisture barrier between curb and shell 30 Oct 0600, R2097321 Commitment 27, Item (17)

Oyster Creek Outage Inspection License Renewal Commitments - IP 71003 Cavity Strippable Coating prior to flood-up 27 Oct 1500, R2098683 Commitment 27, Item (2)

Isolation Condenser One-time Inspection of two stainless steel pipe sections in stagnant or low flow area in the Isolation Condenser System, to verify no stress corrosion cracking.

A2184119 (AR/Library)

?? NOT yet scoped into outage Commitment 24, Item (8)

Isolation Condenser One-time Inspection UT of "B" Isolation Condenser shell below the waterline, to verify no pitting corrosion and confirm effectiveness of Water Chemistry Program.

?? May have been completed in previous outage Commitment 24, Item (2)

Feeder Cable to Auxiliary Transformer (Bank 4)

Inaccessible Medium Voltage Cable Perform power factor test of 4 kV transformer feeder cable 30 Oct 1000, R2026131 Commitment 36 Feeder Cable to Startup Transformer (Bank 6)

Inaccessible Medium Voltage Cable Power factor test of 4 kV transformer feeder cable 2 Nov 0600, R2033700 Commitment 36 Feeder Cable to P-37-1 Inaccessible Medium Voltage Cable Hi-Pot feeder cable 29 Oct 0500, R2054006 Commitment 36 Feeder Cable to P-37-5 Inaccessible Medium Voltage Cable Hi-Pot feeder cable

?? Oct ??, R2059713 Commitment 36 Cable Inspection in Trunion Room Visually inspect a representative sample of accessible cables and connections located in adverse localized environments, for indications of accelerated insulation aging 26 Oct 0400, R2122597 Commitment 34

Oyster Creek Outage Inspection License Renewal Commitments - IP 71003 Cable Inspection in Drywell Visually inspect a representative sample of accessible cables and connections located in adverse localized environments, for indications of accelerated insulation aging 29 Oct 0500, R2122597 Commitment 34 ESW Expansion Joint Periodic inspection 27 Oct 1400, R2081668 Commitment ??

ESW Buried Pipingc Replace previously un-replaced buried ESW piping

?? May have been completed in previous outage Commitment 63 ESW Intake Structure Periodic inspection of components submerged in salt water Structures Monitoring Program, inspect ESW/SW piping & components located under the Deck NOT yet scoped into outage NOT yet planned

?? R2120584 ??

Commitment 31 Item (7)

Commitment 32 Item (2)