10 CFR 50.55a VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 January 30,2009 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Serial No.
NL&OS/ETS Docket No.
License No.
08-0595A RO 50-338 NPF-4 VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION)
NORTH ANNA POWER STATION UNIT 1 REVIEW AND APPROVAL SCHEDULE - FOURTH INTERVAL INSERVICE INSPECTION PLAN AND ASSOCIATED PROPOSED ALTERNATIVES AND RELIEF REQUESTS In a letter dated October 17, 2008 (Serial No. 08-0595), Dominion submitted the North Anna Power Station Unit 1 inservice inspection (lSI) program for the fourth inservice inspection (lSI) interval applicable to Class 1, 2, and 3, components and component supports. The lSI Plan described the programmatic aspects of lSI examinations of components and component supports.
Dominion requested review and approval of the associated relief requests by April 30, 2009 in order to implement the Plan at the start of the fourth lSI interval.
In a January 7, 2009 phone call, Dominion and the NRC discussed the need for each relief request.
It was determined that the majority of the relief requests were not required until October 2009.
Consequently, NRC review and approval of these requests could be deferred until October without effect on implementation of the fourth interval lSI program.
However, one relief request (NDE-004) is considered necessary for the start of the fourth interval to address any leak discovered in the Service Water System.
Therefore, Dominion continues to request approval of NDE-004 by April 30, 2009.
North Anna Unit 1 was not designed or licensed to standards that completely meet the detailed lSI examination and system pressure test requirements presently specified in the 2004 ASME Code.
Therefore, fourth interval program relief requests were submitted pursuant to 10 CFR 50.55a (a)(3)(i) and/or (ii) or 10 CFR 50.55a(g)(5)(iii) to request an alternative or relief from the specific code requirements.
The following summarizes the applicable paragraph of 10 CFR 50.55a for each requested relief/alternative:
Relief NDE-001 NDE-002 NDE-003 NDE-004 NDE-005 NDE-006 10 CFR 50 paragraph 10 CFR 50.55a(a)(3)(ii) 10 CFR 50.55a(a)(3)(ii) 10 CFR 50.55a(a)(3)(ii) 10 CFR 50.55a(g)(5)(iii) 10 CFR 50.55a(a)(3)(i) 10 CFR 50.55a(a)(3)(ii)
Relief SPT-001 SPT-002 SPT-003 SPT-004 SPT-005 SPT-006 G8-001 10 CFR 50 paragraph 10 CFR 50.55a(a)(3)(ii) 10 CFR 50.55a(a)(3)(i) 10 CFR 50.55a(a)(3)(ii) 10 CFR 50.55a(a)(3)(ii) 10 CFR 50.55a(a)(3)(ii) 10 CFR 50.55a(a)(3)(ii) 10 GFR 50.55a(a)(3)(i)
Serial No. 08-595A Docket No. 50-338 Review and Approval Schedule Fourth Interval lSI Plan Page 2 of 2 If you have any questions or require additional information, please contact Mr. Thomas Shaub at (804) 273-2763.
Respectfully, rice resident - Nuclear Engineering Commitments made in this letter:
- 1. None cc:
U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW Suite 23T85 Atlanta, Georgia 30303 Mr. J. E. Reasor, Jr.
Old Dominion Electric Cooperative Innsbrook Corporate Center 4201 Dominion Blvd.
Suite 300 Glen Allen, Virginia 23060 NRC Senior Resident Inspector North Anna Power Station Ms. D. N. Wright NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North MaiI Stop 0-8 H4A 11555 Rockville Pike Rockville, Maryland 20852 Mr. J. F. Stang, Jr.
NRC Project Manager U. S. Nuclear RegUlatory Commission One White Flint North MaiI Stop 0-8 G9A 11555 Rockville Pike Rockville, Maryland 20852