ML071160038
| ML071160038 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 04/24/2007 |
| From: | Hufnagel J Exelon Corp |
| To: | Ashley D NRC/NRR/ADRO/DLR |
| References | |
| TAC 8261 | |
| Download: ML071160038 (121) | |
Text
Info related to Hearing Page I of I
- Donnie, Following up our earlier discussion, the attached files submitted to the ASLB on 3/30 comprising the Motion for Summary Disposition contain info related to the details of the small area acceptance criterion and transition from the assumed 0.536" area out to the assumed 0.736" area. Pete's affidavit includes information and a diagram, and it also makes reference to Reference 22 of the large information package submitted to ACRS on December 8, 2006. The specific item was a GE Nuclear report, which is attached below.
Please let me know if that helps.
Talk with you later.
- John.
<<Summary Dismissal Motion cert and Exhs 1 and 2.pdf>> <<Summary Dismissal - Exhibit 3.pdf>> <<Summary Dismissal Supporting Affidavits.pdf>> <<22 Fixity local thinning.pdf>>
This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies.
This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout.
Thank You.
file://C:\\temp\\GW}OOOO1.HTM 04/24/2007
I c:\\tem p\\GW}00002.TMP Page 1 1 Mail Envelope Properties (461405E8.871 : 3 : 22641)
Subject:
Creation Date From:
Created By:
Info related to Hearing 04/04/2007 4:07:44 PM
<john.hufnagel(dexeloncorp.com>
iohn.hufnagel a(,exeloneoro.com Recipients nrc.gov OWGWPO0 I.HQGWDO01 DJAI (D. Ashley)
Post Office OWGWPOOI.HQGWDOOI Route nrc.gov Files Size Date & Time MESSAGE 1655 04 April, 2007 4:07:44 PM TEXT.htm 2546 Summary Dismissal Motion cert and Exhs I and 2.pdf 1422941 Summary Dismissal - Exhibit 3.pdf 363739 Summary Dismissal Supporting Affidavits.pdf 1064950 22 Fixity local thinning.pdf 2676441 Mime.822 7572809 Options Expiration Date:
Priority:
ReplyRequested:
Return Notification:
Concealed
Subject:
Security:
None Standard No None No Standard Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 1 1 D. Asly-Sm ayDsislMto crJn xs1ad2pfPg I
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD Before Administrative Judges:
E. Roy Hawkens, Chair Dr. Paul B. Abramson Dr. Anthony J. Baratta In the Matter of:.
AmerGen Energy Company, LLC (License Renewal for Oyster Creek Nuclear Generating Station)
March 30, 2007 Docket No. 50-219 AMERGEN ENERGY COMPANY, LLC MOTION FOR
SUMMARY
DISPOSITION ON CITIZENS' DRYWELL CONTENTION I-WA12677106
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 2]
TABLE OF CONTENTS TITLE Page(s)
- 1.
INTRODUCTION 3
Ii.
LEGAL STANDARDS 4
A.
Standards for Sum m ary Disposition................................................................
4 B.
Standards for License Renew al..........................................................................
7 III.
THE SCOPE OF THE ADMITTED CONTENTION...................................................
9 A.
T he C ontention and its B ases............................................................................
9 B.
Issues Outside the Scope of the Contention.....................................................
10 IV.
RELEVANT TECHNICAL BACKGROUND AND CORRECTIVE ACTIONS......... 13 A.
Physical L ayout..............................................................................................
.. 13 B.
OCNGS Identified the Problem and Fixed It...................................................
14 C.
Recent Monitoring Confirmed that Corrective Actions are Adequate........
16 D.
Comm itments Relevant to the Contention.......................................................
17 V.
CITIZENS HAVE FAILED TO IDENTIFY ANY GENUINE ISSUE OF M A T E R IA L FA C T...................................................................................................
18 A.
Intro d u ction...................................................................................................
18 B.
Citizens' Allegation that the Drywvell Is 0.026 Inches From Violating AmerGen's Acceptance Criteria Presents No Genuine Issue of Material F a c t.........................
...... 19 C.
Citizens' Allegation that, Under Corrosive Conditions, Long-Term Corrosion Rates of More Than 0.017 Inches Per Year Have Been Observed, Fails to Present a Genuine Issue of Material Fact.......................... 22 D.
Citizens' Allegation that a UT Monitoring Frequency of Once Per Year or More Is Necessary Presents No Genuine Issue of Material Fact.....................
28 E.
Citizens' Allegation that If the Next Scheduled UT Monitoring Shows that These Safety Margins Have Narrowed, then Even More Frequent Monitoring Would Be Needed Presents No Genuine Issue of Material Fact...... 29 F.
Citizens' Allegation That UT Monitoring is Necessary Even Where Visual Inspections of the Epoxy Coating Do Not Reveal Coating Deterioration Presents No Genuine Issue of M aterial Fact...................................................
29 V I.
C O N C L U SIO N S.......................................................................................................
.. 3 1 2
.D. Ashley-Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 3 D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 3]
INTRODUCTION AmerGen Energy Company, LLC ("AmerGen") hereby requests that the Atomic Safety and Licensing Board ("Board") grant summary disposition, pursuant to 10 C.F.R. § 2.1205, in favor of AmerGen on Citizens' 1 sole contention admitted by the Board related to the frequency of AmerGen's ultrasonic testing ("UT") of the drywell shell in the "sand bed" region of the Oyster Creek Nuclear Generating Station ("OCNGS").
The record in this proceeding and the sworn affidavits accompanying this Motion demonstrate that there is no genuine issue as to any material fact, and that AmerGen is entitled to a decision in its favor as a matter of law. In particular, there is no genuine issue of material fact that calls into question whether AmerGen's scheduled UT monitoring frequency for the sand bed region of the drywell is sufficient to maintain an adequate safety margin, in accordance with U.S.
Nuclear Regulatory Commission ("NRC") requirements applicable to the renewal of the OCNGS license. Because AmerGen's UT monitoring frequency fully complies with those applicable requirements, AmerGen is entitled to a decision as a matter of law.
Section I1 of this Motion sets forth the applicable NRC legal standards governing summary disposition motions and license renewal.Section III frames Citizens' admitted contention by addressing those issues that are within the scope of the contention and those that are not.Section IV presents technical background necessary to understand why the admitted contention is based on speculation, a misunderstanding of the governing acceptance criteria, and simple math errors.Section V discusses why there are no genuine issues of material fact and why AmerGen is entitled to a decision as a matter of law. The latter section is supported by "Citizens" are comprised of: Nuclear Infonnation and Resource Service; Jersey Shore Nuclear Watch, Inc.; Grandmothers, Mothers and More for Energy Safety; New Jersey Public Interest Research Group; New Jersey Sierra Club; and New Jersey Environmental Federation.
71 I
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf r-dyu n various sworn affidavits, which are appended to this Motion,Section V provides AmerGen's conclusions.
I!.
LEGAL STANDARDS Pursuant to 10 CF.R. § 2.1205(c), the Board must base its ruling on a summary disposition motion in this Subpart L proceeding on the standards for summary disposition set forth in 10 C.F.R. § 2.710, as applied to the license renewal regulations set forth in 10 C.FR. Part 54.
A.
Standards for Summary Disposition This proceeding is governed by the informal adjudicatory procedures prescribed in Subpart L of 10 C.F.R. Part 2..2 Pursuant to 10 C.F.R. § 2.1205 in Subpart L, any party may submit a motion for summary disposition at least 45 days before the commencement of a hearing.3 The motion must be in writing and include a written explanation of the basis for the motion, and affidavits to support statements of fact 2 In ruling on the motion, the Board is directed to apply the standards for summary disposition in Subpart G of Part 2, which are set forth in Section 2.710(d)(2).- Pursuant to that section, "the presiding officer shall render the decision sought if the filings in the proceeding....
together with the statements of the parties and the affidavits, if any, show that there is no genuine issue as to any material tfct and that the moving party is entitled to a decision as a matter of law." 6 Section 2.710 generally retains the provisions in former Section 2.749, prior to the AmerGen Energy Co., LLC (License Renewal for Oyster Creek Nuclear Generating Station), LBP-06-07, 63 N.R.C. 188, 228 (2006) ("LBP-06-07"),
10 C.F.R. § 2.1205(a).
id. A separate statement of facts is not required under Subpart L. Compare id. with 2.71 0(a); see also 69 Fed. Reg. 2182, 2228 (Jan. 14, 2004) (section 2.1205 "provides a simplified procedure for summary disposition in informal proceedings.").
1 0 C.F.R. at § 2.1205(c).
See Exrlon Geeratio, Coipaonv, LLC (Early Site Permit for Clinton ESP Site). LBP 19, 62 N.R.C.
134. 179-80 (2005) 4
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 5 revision of Part 2 in January 2004.' Therefore, precedents under the former Section 2.749 are applicable to motions for summary disposition under the current provisions in 10 C.F.R.
§§ 2.710 and 2.1205.
The Commission has held that motions for summary disposition under Section 2.749 are analogous to summary judgment motions under Rule 56 of the Federal Rules of Civil Procedure, and should be evaluated by the same standards.' As held by both the courts and the'former NRC Atomic Safetyand Licensing Appeal Board, summary disposition is not simply a "procedural shortcut"; rather, it is designed "to secure the just, speedy and inexpensive determination of every action," and should be granted when appropriate,5 In fact, 10 C.F.R. § 2.710(d)(1) authorizes a Board to consider a summary disposition motion if "its resolution will serve to expedite the proceeding if the motion is granted." In this case, summary disposition on Citizens' only admitted contention would terminate the proceeding. 0 Pursuant to both NRC and federal case law, the party seeking summary disposition must show the absence of a genuine issue as to any material fact.'- In response, the party opposing the motion must set forth speciflc facts showing that there is a genuine issue.L' To be considered a genuine issue of material fact, "the factual record, considered in its entiretv, must be enough in doubt so that there is a reason to hold a hearing to resolve the issue.""
Bare assertions or general 69 Fed. Reg. at 2227.
Advanced Med. Sms., Inc. (One Factor Row, Geneva, Ohio 44041), CLI-93-22, 38 N.R.C. 98, 102 (1993).
Celotex Corp, v. Catret, 477 U.S. 317, 327 (1986) (citations omitted); see also La. Enrichment Servs. L.P.
(National Enrichment Facility), CLI-06-15, 63 N.R.C. 687, 700 (2006) (affirming Board grant of summary disposition); Advanced Med. Svs., Inc., 38 N.R.C. 98; Tenn. Valetv Auth. (Hartsville Nuclear Plant, Units I A, 2A, I B, and 2B), ALAB-554, 10 N.R.C. 15, 19 (1979).
On February 6, 2007, Citizens submitted one additional proposed contention. Even if the Board were to admit this or another contention, the grant of summary disposition otn Citizens' admitted contention would clearly reduce the number of issues to be decided and expedite the proceeding.
See Adickes v. Kress & Co., 398 U.S. 144, 157 11970); Advonced Medical Syt-ens, Inc., 38 N.R.C. at 102.
-2 See I0 C.F.R. § 2.710(b).
J-1 C/eveland Elec. Illuminating Co. (Perry Nuclear Power 1Plant, Units I and 2), LB P-83-46, 18 N.R.C, 218, (footnote continued) 5
D. Ashle Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 6 denials are insufficient to oppose a motion for summary dispositionU as are mere "quotations from or citations to [the] published work of researchers [or experts] who have apparently reached conclusions at variances with the movant's affiants.,1 5 Furthermore, if the party opposing the motion fails to controvert any material fact, then that fact will be deemed admitted.h If the moving party makes a proper showing, and the opposing party does not show that a genuine issue of material fact exists, then the Licensing Board may summarily dispose of the contention on the basis of the pleadings.1L The existence of conflicting expert testimony does not preclude summary disposition.-
First, the expert witness/affiant must be competent to testify to the matters stated in the affidavit.L9 The Licensing Board may look at whether the witness qualifies as an expert by "knowledge, skill, experience, training, or education.'"2-Second, the Board "must focus on whether the expert opinions are sufficiently grounded upon a factual basis."21 As such, the nonmoving party cannot defeat summary disposition by presenting "subjective belief or unsupported speculation," or improperly supported expert opinion..-2 Thus, in opposing 223 (1983) (emphasis added).
L4 See 10 C.F.R. 2.710(b); Advanced Med. Si's.. Inc., 38 N.R.C. at 102; Houston Lighting and Power Co.
(Aliens Creek Nuclear Generating Station, Unit I), ALAB-629, 13 N.R.C. 75, 78 (1981).
.U Carolina Power & Light Co. (Shearon Harris Nuclear Plant, Units I and 2), LBP-84-7, 19 N.R.C. 432, 435-36 (1984); see also United States v. Various Slot Machines on Guamn, 658 F.2d 697, 700 (9th Cir. 1981)
(holding that "in the context of a motion for summary judgment, an expert must back up his opinion with specific facts" in an affidavit).
See 10 C. F.R. § 2.710(a); Advanced Med. Svs., Inc., 38 N.R.C. at 102-3.
12 N. States Power Co. (Prairie Island Nuclear Generating Plant, Units I and 2), CLI-73-12, 6 A.EC. 241,242 (I 973), uff'd sub. nomn. BPI v. AEC, 502 F.2d 424 (D.C. Cir. 1974).
See Duke Cogemna Stone & Webster (Savannah River Mixed Oxide Fuel Fabrication Facility), LBP-05-04, 61 N.R.C. 71, 80-81 (2005) ("DCS").
L) 10 C.F.R. §* 2.71 0(b).
DCS, LBP-05-04, 61 N.RC. at 80, citing Fed. R, Evid. 702.
Id at 81.
Id. at 80 (quoLing Daubert v. Merrell Dow Pharmaceuticals, Inc., 509 U.S. 579. 589-90 (1993)),
Id. at St 6
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 7 summary disposition, "expert opinion is admissible,only if the affiant is competent to give an expert opinion and only if the factual basis for that opinion is adequately stated and explained in the affidavit."L4 As discussed below, Citizens' contention is the type of contention for which no evidentiary hearing is necessary because it is based on speculation, a misinterpretation of the "local area" average thickness criterion, and simple errors in math. "To oppose... summary disposition, mere bare assertions, even assertions by an expert, without a fully explained factual basis are insufficient to create a genuine and material factual dispute."
Accordingly, the contention can be readily and expeditiously resolved in AmerGen's favor through summary disposition.
B.
Standards for License Renewal The basic standards governing the issuance of renewed licenses for operating commercial nuclear power plants are set forth in 10 C.F.R. §§ 54.21 and 54.29. The former requires AmerGen to demonstrate "that the effects of aging will be adequatelv managed so that the intended function(s) will be maintained consistent with the CLB for the period of extended operation."- The latter, as applied to the OCNGS drywell, requires the NRC to determine that AmerGen has identified and has or will take action to manage the effects of aging during the period of extended operation on the functionality of the drywell, so that there is "reasonable assurance that the activities authorized by the renewed license will continue to be conducted in accordance with the [current licensing basis ("CLB")], and that any changes made to the plant's L4 Id.
25 I. at 100.
L 10 C.F.R. § 54.21(a)(3) (emphasis added).
7
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 81 CLB...
are in accord with the Act and the Commission's regulations."
Both regulations thus require "reasonable assurance" that the effects of aging will be "adequately managed."2' Finally, AmerGen is required to establish an overall Aging Management Program
("AMP") that provides reasonable assurance that the effects of aging are effectively managed such that the drywell will perform its intended function during the period of extended operation.
consistent with the CLB. AmerGen has defined an AMP for the dryvell whosepuipose is to do just that. AmerGen's AMP for the drywell shell is based upon American Society of Mechanical Engineers ("ASME") Code Section X1, Subsection IWE for steel containments (Class MC), in accordance with the provisions of 10 C.F.R. §.50.55a.-
Section Xl, Subsection IWE is approved for use by tile NRC in 10 C.F.R. § 50.55a and, therefore, is not subject to challenge in this proceeding.9 While Citizens' contention challenges only the frequency of AmerGen's planned UT of the sand bed region, that UT is only a part of AmerGen's overall AMP. Citizens' contention fails to account for the remainder of AmerGen's AMP for managing corrosion. So long as AmerGen's AMP for managing corrosion in the sand bed region, taken as a whole, provides the requisite reasonable assurance, AmerGen satisfies the applicable requirements of 10 C.F.R. Part 54.
As demonstrated below, AmerGen's AMP satisfies Part 54 and, accordingly, summary disposition is appropriate.
10 C.F.R. § 54.29(a) (emphasis added),
Citizens' contention argues that a worst case projection of corrosion is needed, when there is no support for that either factually or legally. There is no regulatory basis for Citizens' demand.
S
-Motion for Leave to Add Contentions and Motion to Add Contentions (Dec. 20, 2006) ("December 20 Motion to Add Contentions"), Exh. ANC-I at 49 ("LRA Supplement").
L See AmnrGen Eneergy Co.. LLC (License Renewal for Oyster Creek Nuclear Generating Station) LBP 22 (slip op. at 24) (Oct. 10. 2006) ("LI3P-06-22").
8
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 9 III.
THE SCOPE OF THE ADMITTED CONTENTION A.
The Contention and its Bases Citizens' contention as admitted by the Board states:
AmerGen's scheduled UT monitoring frequency in the sand bed region is insufficient to maintain an adequate safety margin.3 The Board explained Citizens' argument as follows:
Citizens argue that - because the corrosion rate in the sand bed region is unknown due to the uncertain corrosive environment -
AmerGen's proposed plan to perform UT tests prior to the period of extended operation, two refueling outages later, and thereafter at an appropriate frequency not to exceed 10-year intervals, is insufficient to maintain an adequate safety margin.L The admitted contention is, therefore, limited to the frequency of UT measurements of the sand bed region of the OCNGS drywell shell?2 The "foundation" of Citizens' argument is that "UT measurements must be taken at least annually because the historical corrosion rate has been such that, if corrosion were to resume at that rate, the safety margin would be eliminated within two years." The only "bases" for Citizens' contention, as explained by the Board,35 are:
."the drywell shell is 0.026 inches or less from violating AmerGen's acceptance criteria";
- 2.
"[u]nder corrosive conditions, long-term corrosion rates of more than 0.01 7 inches per year have been observed";
It Id at 9.
L Idat 15.
L Citizens attempted to expand the scope of the litigation beyond the frequency of UT measurements on several occasions, to regions of the drywell shell above and below the sand bed region, as well as to other components within the scope of AmerGen's AMP. See id. at 5-6: AierGen Energy Co., LLC (License Renewal for Oyster Creek Nuclear Generating Station). LBP-06-11, 63 N.R.C. 399, 393-94 (Mar. 22, 2006) ('"LBP-06-1 I"). The Board, however, rejected these attempts. See LIBP-06-22 (slip op. at 5-6, 36);
LBP-06-1 I, 63 N.R.C. at 393-394, 402; Memorandum and Order (Denying Citizens' Motion for Leave to Add Contentions and Motion to Add Contention) (Feb. 9. 2007) (unpublished).
L4
-BP-06-22 (slip op. at 20 n. 16).
hi. at 15, 17 (quoting Citizens' Supplement to Petition to Add a New Contention at 9, 12 (July 25, 2006)
("July 25 Supplement"), and the June 23 and July 25, 2006 Memoranda from Dr. Rudolf H. HIausler to Richard Webster, Esq.).
9
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 10
- 3.
"[t]hus, if corrosive conditions are possible, a UT monitoring frequency of once per year or more would be necessary to prevent violation of the acceptance criteria";
- 4.
"if the next scheduled UT monitoring that is to occur before the end of the licensing period shows that these safety margins have narrowed, even more frequent monitoring would be needed"; and
- 5.
"UT monitoring is necessary even where visual inspections of the epoxy coating do not reveal that the coating has deteriorated, because corrosion may occur under the epoxy coating in the absence of visible deterioration due to non-visible holidays, or pinholes."
Throughout Citizens' Petition and Supplement,A and the accompanying memoranda from Dr.
Rudolf Hausler, Citizens make a number of other allegations regarding the thickness of the drywell, potential corrosion rates, and future compliance with the applicable acceptance criteria.
The Board did not recognize those arguments as adequate bases in LBP-06-22 and, therefore, they need not be addressed in this Motion for Summary Disposition. Accordingly, AmerGen demonstrates in Section V, below, why there is no genuine issue as to any material fact with respect to the bases that the Board recognized, and that AmerGen is entitled to a decision in its favor as a matter of law.
B.
Issues Outside the Scope of the Contention But first, because Citizens have a history of rearguing issues that the Board has explicitly precludecd,l AmerGen lists those areas that remain outside the scope of the contention so there is no confusion about what may be litigated as part of this proceeding:
- 1.
The upper and embedded regions of the drywell. The Board admitted Citizens' contention challenging the adequacy of AmerGen's UT monitoring frequency of the L
Citizens' Petition to Add a New Contention (June 23. 2006) ("June 23 Petition"); July 25 Supplement.
U Sec e.g.. Motion (br Leave to Add a Contention and Motion to Add a Contention (Feb. 6, 2007) ("February 6 Motion to Add New Contention"); Citizens' Motion for Reconsideration of Motion to Add New Contentions or Supplement the Basis of'the Current Contention and Leave to File Such a Motion (Aug. 6, 2006): December 20 Motion to Add Contentions.
10
I Page 11 J
0 D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page_ 11 drywell shell in the sand bed region.2 LBP-06-22 and previous orders in this proceeding make it clear that the scope of Citizens' admitted contention is limited to the sand bed region, and thus issues related to the upper region and embedded region of the drywell are excluded from litigation.-11
- 2.
The acceptance criteria for determining the minimum required thickness of the drywell. In rejecting everv aspect of Citizens' reformulated contention except for the frequency of AmerGen's UT monitoring in the sand bed region, the Board ruled that "any challenge to the adequacy of AmerGen's acceptance criteria should have been made at the time Citizens filed their initial Petition to Intervene. It cannot be submitted at this late juncture."L Thus, Citizens may not challenge the origin, derivation or adequacy of AmerGen's minimum required thickness acceptance criteria. To the extent that AmerGen demonstrates that its UT monitoring frequency is adequate to provide reasonable assurance that those acceptance criteria will continue to be satisfied during the period of extended operations, it also will have demonstrated that the frequency of UT monitoring proVides "an adequate safety margin," and answered the allegations in the contention.
- 3.
The monitoring programs for moisture and coating integrity. The adequacy of AmerGen's moisture monitoring program may not be litigated.1 This includes AmerGen's Protective Coating Monitoring and Maintenance Program ("PCMMP") and AmerGen's plans for L
LBP-06-22 (slip op. at 9).
, See LB11-06-07, 63 N.R.C.188,216 n. 27 (2006) (limiting Citizens' original contention of omission to the sand bed region); AmerGen Energy Co.. LLC (License Renewal for Oyster Creek Nuclear Generating Station), LBP-06-16, 63 N.R.C. 737, 744 (2006) ("LBP-06-16") (allowing Citizens to file a new contention "raising a specific substantive challenge to AmerGen's new periodic UT program for the sand bed region" and directed that "the substance of [the new contention] must be limited to the sand bed region").
4 LBP-06-22 (slip op. at 14).
Li Id. at 25.
II
I I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 12]
I
.Ahe umr imsa oio etadEh n
.d ae1 periodic visual inspections of the epoxy coating on the exterior of the sand bed region of the drywell.42
- 4.
AmerGen's response to any wet conditions and coating failure. The Board ruled that this aspect of Citizens' contention "effectively challenges the adequacy of AmerGen's PCMMP," and that since "AmerGen has committed" to an ASME Section XI, Subsection IWE compliant program, "Citizens are prohibited from challenging its adequacy.'-3
- 5.
'Where UT measurements are taken. Citizens alleged, in their reformulated contention, that the spatial scope of AmerGen's UT monitoring was insufficient to systematically identify' and sufficiently test all the degraded areas in the sand bed region.4-The Board rejected Citizens' untimely challenge to the spatial scope of AmerGen's UT monitoring regime because information regarding when and where UT measurements would be taken was available long before they submitted their new petition. Thus, "the appropriate time for a challenge by Citizens to the spatial scope of AmerGen's UT measurements was promptly after AmerGen docketed its December commitment."'s-
- 6.
The quality assurance program for UT measurements. The Board ruled that the adequacy of AmerGen's quality assurance program for UT measurements is not admissible noting, among other things, that "a licensee's quality assurance program is excluded from license renewal review" and that "Citizens' attack on AmerGen's quality assurance program is outside the scope of this proceeding."-IL 42 Id. at 23.
4 Id. at 26, 27.
!L Id. at 28.
45 Id. at 30.
L Id. at 32, 33.
12
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 13l1 r Gen analyzes UT measurements. Finally, the Board held that lues" and methodology for determining a corrosion rate are cope of the contention. -27
'ICAL BACKGROUND AND CORRECTIVE ACTIONS brief summary of the facts relevant to historical corrosion of the
-ckground is necessary to understand why the bases supporting the "ted by only speculation, a misinterpretation of the "local area" simple errors in math.
A.
Physical Layout The OCNGS drywell shell is a steel pressure vessel in the shape of an inverted light bulb, with a spherical lower section and a cylindrical upper section located inside the Reactor Building. Exhibits I and 2 depict the drywell shell and show, in particular, the sand bed region.
The drywell shell has a bottom elevation of 2' 3" and a top elevation of about 100'.L8 It is embedded in concrete on both sides from its bottom until elevation 8'1 1".-9 From there until OLi-'
.4...
,.n,,
4..,
4,..,
,[
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf
,Page 14 1 of the drywell shell in this area was filled with sand and, although the sand was removed about 15 years ago, this area is still called the "sand bed" region. This region of the shell is spherical and is divided into ten "bays" by the torus vent headers that connect the interior of the drywell to the torusY2 B.
OCNGS Identified the Problem and Fixed It In 1980, water was observed coming from the sand bed drains.53 The source of the water was subsequently confirmed to be leakage through small cracks in the reactor cavity liner. This leakage occurred only during refueling, when the reactor cavity was flooded, and should have been collected by a concrete trough and 2" drain pipe located beneath the refueling cavity bellows. The amount of water, however, was greater than the capacityof the trough and drain pipe. Furthermore, because the curb of the trough did not contain the water, the water instead flowed into the gap between the exterior of the drywell shell and the concrete shield wall, down to the sand bed region. Exhibit I shows the general location of the refueling cavity, the drywell shell, and the concrete shield wall.
Five floor drains are designed to remove any water that might reach the sand bed region.
However, not all of these drains historically performed as designed because they were either blocked or partially clogged. Also, the sand bed concrete floor in some bays was found to be unfinished, resulting in drains being located above the floor elevation.
The presence of corrosion-promoting water, elevated operating temperature, and sand (acting to keep the water in contact with an uncoated drywell shell) caused corrosion of the exterior of the drywell shell prior to the implementation of corrective actions. The corrosion was 5
Exhibit I. The surface of the floor in some of the bays was repaired with epoxy.
LI The bays are designated only with odd numbers, from I through 19.
L Id. at 1-2, 2-1, 4-1. This historical overview can be found in the LRA, the LRA supplement, and the ACRS February I, 2007 transcript.
14
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 151 D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 15 not, however, evenly distributed either among or within the ten bays. In general, corrosion was greatest in the vicinity of the torus vent headers and not in the middle of the bay. In addition, corrosion was greatest near the air-water interface located near the top of the sand bed region, between approximately elevations 11' and 12'. This area has been referred to as the "bath tub ring" of corrosion. For reference, the as-designed thickness of the drywell shell in the sand bed region was 1.154". The uneven distribution of corrosion resulted in a maximum general average metal loss of about 0.35" in part of Bay 19, and almost no metal loss in Bay 3.4 The maximum observed corrosion rate prior to 1992 was near 0.040" per year.55 Corrective actions initiated in the late 1980s and early 1990s to prevent additional corrosion of the exterior drywell shellin the sand bed region included:
0 applying metal tape and a strippable coating to the reactor cavity, prior to flooding for refueling outages, to reduce the amount of water leaking through the liner to at least below the capacity of the 2" drain line below the bellows;-
repairing the concrete curb below the refueling bellows to ensure that any water that reaches this area is directed to the 2" drain line; removing the sand from the sand bed region; repairing and finishing the concrete floor in those bays in the sand bed region that were unfinished, to ensure any water that entered that region would be directed to the sand bed drains:
clearing the five sand bed drains; removing the corrosion products from the exterior of the drywell shell in the sand bed region; and coating the exterior of the drywell shell in the sand bed region with a multi-layered epoxy system (i.e., one pre-primer coat, and two top coats) to prevent any water or moisture that might reach the sand bed region firom contacting the exterior shell.
4 See ACRS Intb. Package. Table 1, at 6-2.
Id. at 6-1, 8-4.
Metal tape and strippable coating were not applied during the 1994 and 1996 outages, but have been applied during each refueling outage since then.
15
Page 16 I
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 16 These corrective actions have protected the exterior of the drywell shell in the sand bed region from further corrosion. Accordingly, corrosion of the exterior of the drywell shell in the sand bed region has been arrested.
C.
Recent Monitoring Confirmed that Corrective Actions are Adequate AmerGen collected data during the October 2006 refueling outage which demonstrate that the corrective actions identified above are effective at preventing water from reaching the sand bed region, and protecting the drywell shell in the sand bed region.
Specifically, ArnerGen confirmed that no water leaked to the sand bed region through monitoring of the refueling trough drain and the five sand bed drains, as well as through visual inspection of the sand bed floor and drywell shell in all ten bays.
AmerGen also performed VT-I (i.e., visual) inspections of the epoxy coating in all ten bays in the sand bed region in accordance with ASME Section XI IWE. The VT-I-qualified inspectors did not identify any defects or deterioration of the epoxy coating. These visual inspections confirm that corrosion of the external drywell shell in the sand bed region remains arrested. AmerGen also took internal and external UT measurements of the drywell shell in all ten bays in the sand bed region: it took internal measurements from the 19 "grids" located at about elevation I 1'3", which were measured in 1992, 1994, and 1996; and it took external measurements from approximately 100 "points" at various elevations.throughout the ten bays, which were last measured in 1992. There are no statistically-significant differences between the current and previous data, further confirming that corrosion in this area has been arrested.2 L
Leakage can only occur during refueling outages when the reactor cavity is flooded to facilitate moving fuel. AmerGen currently refuels OCNGS every two years.
Citizens recently argued that the 2006 data are significantly different from the 1992 data. See February 6 Petition to Add New Contention, As explained in AmerGen's March 5, 2007 Answer, there is no genuine dispute of material fact on that issue. See also conversation between S. Armijo, ACRS member, and R.
Webster at the February 1, 2007 ACRS meeting. Tr. at 262-63 (Feb. I, 2007) ("Independently, I did something vety similar to what Mr. Licina did, and... I saw the same phenomena....
[T]here are systematic changes, systematic bias and there was no way I could conclude that there was continuing (footnote continued) 16
- 0. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 17 I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 17 1 D.
Commitments Relevant to the Contention AmerGen's AMP must provide reasonable assurance that the effects of aging will be adequately managed so that the intended functions of the drywell will be maintained consistent with the CLB for the period of extended operation.L As part of its AMP, AmerGen has committed to perfonr inspections of the drywell shell. A full list of the docketed commitments related to the AMP for the drywell shell are provided in Exhibit 3.6 For the sand bed region, which is the only region relevant to the admitted contention, these include visual inspections of the epoxy coating that protects the exterior of the drywell shell in all ten bays, every other refueling outage (i.e., every four years). These commitments also include internal and external UT measurements of the drywell shell in all ten bays in the sand bed region every other refueling outage.
At the time the Board admitted this contention, the Board characterized AmerGen's commitment as perfonning UT tests prior to the period of extended operation, two refueling outages later, and thereafter at an appropriate frequency not to exceed 10-year intervals.6" As shown in Exhibit 3, AmerGen has since modified its UT frequency commitment so that it will perform UT measurements during the refueling outage in 2008, and then every other refueling outage thereafter (i.e., every four years), using the same internal grid locations and the more than 100 external "points" that it measured during the 2006 refueling outage.
AmerGen's AMP commitments provide a "safety net" should unanticipated rates of corrosion be found during any refueling outage. In particular, if statistically-significant deviations from the prior UT results are found, AmerGen will take additional measurements to corrosion, that the most reasonable interpretation of the data is that the corrosion had been arrested since 1992.').
L 10 C.F,R. §§ 54.29 and 54.21: see discussion in Section It.tB., above.
L In some cases, these commitments already have been completed.
17
0.
A s l y
- S m a y D s i s l M t o n c r n
x s 1 a d 2 fP g
18 I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 18 1 confirm the readings, promptly notify the NRC, conduct additional visual inspections, perform additional engineering evaluations, and perform an operability determination prior to restart firom the associated outage. Clearly, these commitments provide reasonable assurance that, if unanticipated conditions are found, the plant will not be restarted without a determination, subject to review and concurrence by the NRC Staff, that the applicable acceptance criteria are satisfied. Furthermore, AmerGen's commitment necessarily includes the obligation to conduct more frequent UT thereafter if the established corrosion rates so warrant.
V.
CITIZENS HAVE FAILED TO IDENTIFY ANY GENUINE ISSUE OF MATERIAL FACT A.
Introduction The intended functions of the drywell are to serve as both structural support (i.e., to prevent buckling) and as a pressure boundary.r Before the sand was removed from the sand bed region in 1992, GE performed an engineering analysis of the Oyster Creek drywell shell to determine whether historical corrosion prevented the drywell from performing its intended functions. GE conducted this analysis in 1991, based on ASME Code requirements, to establish the minimum required general thickness, with the sand removed, for both pressure and buckling stresses.L The results of GE's analysis show that the minimum required thickness in the sand bed region is controlled by buckling. Moreover, a general thickness acceptance criterion of 0.736" will satisfy ASME Code requirements with a safety factor~of 2.0 against buckling for the controlling refueling load combination, and 1.67 safety factor for the post-accident load
.L.BP-06-22 (slip op. at 14).
LRA Supplement at 4-5.
ACRS Info. Package at 6-7.
18
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2:pdf P.....
page 1.9 combination (i.e., flooding of the containment).P Accordingly, UT measurements thicker than 0.736" are accepted without further evaluation.
If any local UT measurements reveal a thickness below 0.736", AmerGen performs a separate evaluation to confirm that the locally-thin areas, in the as-found condition, meet the ASME Code. Specifically, locally-thinned areas are evaluated, among other things, against a minimum local average thickness of 0.536" over an area not to exceed one square foot, with a surrounding one-foot transition area to 0.736", such that the total area with thickness below 0.736" is nine square feet.0 Figure I attached to the Affidavit of Mr. Pete Tamburro visually depicts this local area acceptance criterion. There is also a "very local" area average thickness of 0.490" over an area not to exceed 2.5 inches in diameter. 6 As demonstrated below, the admitted contention is based on a misunderstanding of this local area acceptance criterion, followed by impermissible speculation and mathematical errors.
AmerGen discusses each basis for Citizens' contention and demonstrates that Citizens have failed to raise aIny genuine issues of material fact. Accordingly, AmerGen is entitled to a decision in its favor as a matter of law.
B.
Citizens' Allegation that the Drywell Is 0.026 Inches From Violating AmerGen's Acceptance Criteria Presents No Genuine Issue of Material Fact The Board has stated that, according to Citizens, "'the drywell shell is 0.026 inches or less from violating AmerGen's acceptance criteria'."ýrt This allegation does not raise a genuine issue of material fact because, as explained below and in the attached Affidavit of Mr. Peter Tamburro, it is based on speculation, a misinterpretation of the 0.536" local area average See id at 6-8.
See id. at 6-8, 6-18. See u/so Citizens' June 23 Petition, Exh. NC3. at 4-6. Also, as discussed in Section 111.13. above, the Board has ruled that any challenge to the adequacy of those acceptance criteria is beyond the scope of the admitted contention.
5 Id.
~
LBP-06-22 (slip op. at 15),
19
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 20 1 thickness criterion, and simple errors in math. Such bases are ripe for rejection under the standards of summary disposition.9 The sole support offered by Citizens in their June 23 Petition and July 26 Supplement for their first allegation is the memorandum from Dr. Hausler which is appended to Citizens' June 23 Petition ("June 23 Hausler Memorandum"). In that memorandum, Dr. Hausler states:69 Applying the one square foot below 0.736 inches acceptance criterion..., the total area measured below I square foot was around 0.3 square feet. However, this area is very sensitive to additional corrosion because in a length of around 5 inches, the thickness changed from around 0.736 inches to 0.800 inches.
Assurning that the edge of the hole is a straight line, this means.
that a change of 0.064 inches in depth occurs over about 5 inches in length. Thus, for the radius of the thin area to change by two inches, the depth would have to change by only 0.026 inches. If this occurred the total area below 0.736 inches would be approximately 1.6 square feet, well beyond the current acceptance criterion. Assuming a worst case corrosion rate of 0.020 inches per year shows that the area acceptance criterion could be violated in around a year, even if the thin areas have not grown bigger since they were last measured in 1992.
First, from the underlined parts of the quote above, it is clear that Dr. Hausler is speculating about what could happen to the drywell shell as opposed to what has happened. This speculation about future corrosion is unsupported by current data and amounts merely to Dr. Hausler's hypothetical musings. Such speculation does not survive summary disposition.-
Second, as Peter Tamburro demonstrates in Paragraphs 9-18 of his Affidavit, Dr. H-lausler misinterprets the acceptance criteria. The first criterion is a general average thickness of 0.736".
An area of average thickness less than 0.736" remains adequate from a buckling perspective if it See DCS. 61 N.R.C. at 81 (the Board "must focus on whether the expert opinions are sufficiently grounded upon a factual basis").
June 23 Hausler Memorandum at 7 (emphasis added).
M See DCS, 61 N.R.C. at 81.
20
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 21 1 meets the 0.536" local area average thickness criterion."1 Dr. Hausler's discussion assumes that the local area criterion is violated if the area below 0,736" is greater than one square foot.3 Dr. Hausler's interpretation of the local area acceptance criterion is incorrect. He appears to apply that criterion with an abrupt step-change (like a cliff) on all sides of the one square foot area that averages 0,536", such that the thickness increases to 0.736" with no transition.L3 However, AmerGen evaluates locally-thinned areas against, among other things, a minimum local average thickness of 0.536" over an area not to exceed one square foot, with a surrounding one-foot transition area to 0.736", such that the total area with thickness below 0.736" is nine squarefeet.uL Figure 1 attached to Mr. Tamburro's affidavit depicts this local area acceptance criterion. (Citizens are now aware of this transition area.T) Thus, even if Dr. Hausler's speculation that there could in the future be an area ofapproximately 1.6 square feet below 0.736" is correct-which it is not--then the local area acceptance criterion still would not be violated because that criterion allows for an area thinner than 0.736" of nine square feet. Dr.
Hausler's misinterpretation and misunderstanding of the criterion in no way creates a genuine issue of material fact requiring a hearing.
L' See, e.g., Citizens' Exh. NC3, at 5-6.
LA S'ee June 23 Hausler Memorandum at 7 ("If this occurred the total area below 0.736 inches would be approximately 1.6 square feet, well beyond the current acceptance criterion").
22 Tamburro Affidavit, ¶[
20.
_4 See ACRS Info. Package at 6-8, 6-18, discussing GE analyses. See also Citizens' June 23 Petition, Exh.
NC3, at 4-6; id. at 6 ("These [GE] studies contain analyses of the drywell... reducing the [0.736"]
thickness by 0.200 inches in an area 12 x 12 inches in the sandbed region, tapering to original thickness over an additional 12 inches"). AmerGen applies 0.536" and its transition area to 0.736" as a local area acceptance criterion in its calculations, taking into account the location, consfiguration, etc. of the locally thinned areas. Tamburro Affidavit, ¶) 20; see also.. Exhibit 3 to "AmerGen's Answer Opposing Citizens' February 6. 2007 Motion for Leave to Add a Contention and Motion to Add a Contention" (March 5, 2007)
(the "24 Calc.").
See Citizens' February 6 Motion to Add New Contention at 5. ("GE modeled an area of one square foot with a thickness of 0.536 inches, surrounded by a one square foot transition zone back to 0.736 inches... ").
21
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 22 1 Contrary to Citizens' allegations, there is quite a bit more than 0.026" margin remaining before the ASME Code is exceeded. The bounding general average thickness in the sand bed region is 0.800" located in Bay 19, which leaves a margin of 0.064" when compared to the 0.736" general area thickness criterion (i.e.. 0,800"-0.736").2-6 The bounding local area average thickness Dr. Hausler identified is 0.618" in Bay 13, which leaves a margin of 0.082" when compared to the 0.536" local area thickness criterion (i.e., 0.61 8-0.536").71 For all these reasons, only speculation and a misinterpretation of the acceptance criterion support Citizens' assertion that only 0.026" remains before the acceptance criteria are exceeded.
Accordingly, this first basis does not raise a genuine issue of material fact. Mr. Tamburro, in Paragraphs 24-33 of his Affidavit, also explains that Dr. Hausler's allegations are based on mathematical errors which similarly do not raise a genuine issue of material fact. The Board, however, need not delve into Mr. Tamburro's additional explanation about Dr. Hausler's math errors to dismiss the contention because Mr. Tamburro's explanation is in addition to Dr.
Hausler's misinterpretation and misunderstanding of the local area acceptance criterion which is, by itself, enough for the Board to now reject the contention.
C.
Citizens' Allegation that, Under Corrosive Conditions, Long-Term Corrosion Rates of More Than 0.017 Inches Per Year Have Been Observed, Fails to Present a Genuine Issue of Material Fact The next basis statement is that "[u]nder corrosive conditions, long-term corrosion rates of more than 0.017 inches per year have been observed."78 The source of this statement is
- 6 See ACRS Info. Package, Table I, at 6-2. All the other bays have greater margin, ranging from 0.074" in Bay 17, to 0.439" in Bay 3. See id.
71 Tamburro A/flidavir, ¶ 43. Citizens' also stated that AmerGen has "reported that over 20 areas in the sand bed region are now thinner than 0.736 inches and these areas have an average thickness of 0.703 inches."
June 23 Petition at 3. While there are approximately 201 individual UT "point" measurements that are below 0.736", see ACRS Into. Package, Table 2, at 6-12, the existence of these points does not raise a genuine issue of material fact. As discusses above, if any local UT measurements reveal a thickness below 0.736", AmerGen perlorms a separate evaluation to confirm that the locally-thin areas, in the as-found condition, meet the ASM1E Code using a local average thickness of 0.536".
7ý July 25 Supplement at 9.
22
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 23 1 ndum, which relies on a public AmerGen document for the highest long term corrosion rate estimated [by AmerGen per year."2" This statement is unsupported as applied to current or s to create a genuine issue of fact or law requiring a hearing.WO regarding a 0.017" per year corrosion rate are strikingly similar to s expert in the Construction Authorization proceeding for the Facility, which a Licensing Board rejected on summary ase, the intervenor's expert argued that a 7.0-plus magnitude earthquake could occur close enough to affect the facility and, therefore, that the applicant should have included such a large earthquake in the facility's design spectra.-' That Board granted summary disposition in the applicant's favor, finding, in part, that the intervenor's expert "fail(ed] to provide a factual foundation for his assertion that such an earthquake could occur."'3 The Board concluded that "[t]o oppose summary disposition, mere bare assertions, even assertions by.an expert, without a fully explained factual basis are insufficient to create a genuine
- 0. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf I-'age Ld4
ý D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf There are a myriad of reasons why an allegation of a current or future corrosion rate of 0.017" per year does not raise a genuine issue of material fact. First, this rate is solely historical as demonstrated by the basis statement's use of past tense, and AmerGen's document which is the source of the statement. Unsupported speculation that past corrosion rates can occur in the future does not raise a genuine issue of material fact.lý Second, Dr. Hausler can only speculate that this rate of corrosion could occur in the future on the exterior of the drywell shell in the sand bed region. The corrective actions identified in Section III.A., above, demonstrate why such a rate in that region is not reasonable.
The source of water-the flooded reactor cavity liner during refueling outages-has been identified and controlled such that this water is no longer expected to reach the sand bed region when a strippable coating is applied to the refueling cavity liner prior to refueling outages.
Even if some water did reach tile sand bed region it would not have the effect after 1992 that it would have had before that time. As Mr. Barry Gordon explains in Paragraph 13 of his Affidavit, part of the reason why the corrosion rate was historically as high as 0.017" per year in certain bays of the drywell shell sand bed region is because there was a medium (i.e., sand) to physically hold water against the drywell shell. The sand has been removed so there is no water-retaining media to facilitate future corrosion.
Third, Dr. Hausler ignores the flct that the historic corrosion occurred because the drywell shell in the sand bed region was no__t coated. The exterior shell is now protected by a three-layer epoxy coating. As Jon Cavallo states in Paragraph 12 of his Affidavit, this coating system was designed for submerged applications, such as tank bottoms, so even if water was always present in the sand bed region, it would have no effect on the coated steel shell.L
~
See id. at 88 (finding that Interenor's expert failed to provide a scientific explanation for his allegation).
It is not clear that Dr. Hausler is qualified to challenge Mr. Cavallo's affidavit. An affiant must be competent to testify to the matters stated in the affidavit. See 10 CF.R. 2.710(b). Although the Board (footnote continued) 24
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 25 Fourth, if a corrosion rate of 0.017" per year had occurred between 1992 and 2006, then it would have been readily detected by the VT-I (visual) and UT performed during the 2006 refueling outage. Based on the information contained in the VT-i inspection reports generated for the coating in all ten external drywell bays during the October 2006 outage, the epoxy coating is in good condition with no defects or deterioration.L The UT measurements collected from both the interior and exterior of the drywell shell did not identify a corrosion rate of 0.017" per year. Such a rate would have resulted in a loss of 0.238" (0.017" per year x 14 years), which is well within the expected equipment measurement error of 0.020".L Fifth, even if there was a 0.017" per year corrosion rate, Citizens have only argued that it would be localized, and localized corrosion at that rate does not create a genuine issue of material fact. Specifically, Citizens, through Dr. 1lausler, speculate that there might be tiny holes ("pinholes" or "holidays") in the epoxy coating which could allow water to contact the exposed shell in the pinhole or holiday, causing corrosion.L Citizens necessary imply, therefore, that these hypothetical defects in the epoxy coating are material to the contention.
By definition, a pinhole or a holiday is a defect in the original application of the coating.
But the possibility of this kind of defect decreases with each additional coat of epoxy applied.L has accepted Dr. Hausler as an expert relating to corrosion of the drywell shell, the Board has not accepted him as an expert relating to the performance of coatings. See LBP-06-22 (slip op. at t7 n.14). AmerGen believes that Citizens have not introduced information on the record to demonstrate that Dr, Hlausler is quali fied to present an expert opinion on the application and performance of coatings, specifically the mrulti-layer epoxy coating system on the exterior of the OCNGS drywell shell in the sand bred region.
"ramburro Affidavit at ¶ 40.
Id. at ¶ 33.
See e.g. LBP-06-22 (slip op. at 17), citing Citizens' July 25, 2006 Supplement at [2 ("Citizens also state that... corrosion may occur under the epoxy coating in the absence of visible deterioration due to non-visible holidays, or pinholes'); id. at 19, citing Dr. Hausler's Memorandum to R. Webster at (July 25, 2006) ("Hausler's July 25, 2006 Memorandum").
9*'
Cavallo Affidavit at ! 14.
25
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 26 I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf
,Page 26 1 The epoxy protecting the exterior of the drywell shell is comprised of a three layer (a pre-prime and two coats) coating system.
9' In fact, Citizens' argument that such local defects have existed since 1992 is inconsistent with their argument that the air in the sand bed region is moist and capable of corrosion.2 If a moist environment and pinholes coexisted for the past 14 years (1992 to 2006), then the resulting corrosion would be easily visible during the VT-I inspections.9 Even if such tiny defects existed, Dr. Gordon explains in Paragraphs 15-18 of his Affidavit, why they would not allow materially significant corrosion behind the coating even under unrealistic conditions. Dr. Gordon assumes, among other things, that water: enters the sand bed region during a refueling outage when inspections are not performed; finds its way to a pinhole that is conveniently located over the thinnest portion of the shell; begins to corrode the underlying shell immediately at the start of the outage at a rate of 0.039" per year (more than twice the rate Citizens postulate); and does not evaporate from behind the pinhole (terminating the corrosion process) until a year later even though the operating temperature in the sand bed region is 130'F. Sufficient margin remains even under these unrealistic conditions, demonstrating that AmerGen's UT frequency is adequate.
Mr. Tamburro also explains, in Paragraphs 42 and 43 of his Affidavit, why the 0.017" per year corrosion rate that Citizens proffer does not raise a genuine issue of material fact.
Corrosion behind a pinhole or holiday would be analyzed against the "very local" area acceptance criterion of 0.490" which applies to areas not to exceed 2.5 inches in diameter. The thinnest external UT point measurement identified by Dr. Hausler is 0.618", located in Bay 13.
Simple math demonstrates that there is 0.128" of margin available for a pinhole or holiday in this l /d.
92 Id. at 41119.
26
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 27 1 thinned area in Bay 13 (i.e., 0.618"-0.490"), and that it would take more than seven years for this margin to disappear with a corrosion rate of 0.017" per year (i.e., 0.128"/0.0 17 = 7.5 years").
AmerGen, however, is performing UT measurements and visual inspections of the shell in the sand bed region every four years. This frequency demonstrates that there is no genuine issue of material fact requiring a hearing.
Sixth, even if significant corrosion could occur behind a pinhole or holiday in the epoxy coating, Mr. Cavallo explains that corrosion at a rate of 0.017" per year would be visible through the VT--I inspections performed every four years.O-As carbon. steel corrodes, the reaction between oxygen and the iron in the steel results in an iron oxide byproduct. The epoxy coating would not allow the corrosion byproducts to migrate from the site of the corrosion, so these byproducts would either accumulate as a blister at the corrosion site, or they would seep out through the postulated pinhole or holiday, onto the otherwise gray epoxy coating. In either case, the Corrosion byproducts would be clearly visible in a VT-I inspection.
The corrosion byproduct occupies a volume seven to ten times greater than the corroding steel.
For example, if 0.017" of steel corrodes in a year under the epoxy coating, then between 0.119" and 0.170" of byproduct would result. Four years of corrosion at that rate-the interval that AmerGen will perform UT in the sand bed region-would result in between 0.476" and 0.680" of corrosion byproduct.-
This amount of corrosion would, therefore, cause a blister under the epoxy coating of around Y2-inch.L7 Such a blister would be clearly visible by an inspector qualified to perform VT-I inspections.
ý31 Id.
I' d. at !118.
Id. at ¶17.
92 To put this ludicrous alleged rate in perspective, a corrosion rate of 0.017" occurring in a pinhole since 1996 (which was the last time that strippable coating was not used during a refueling outage), would result (footnote continued) 27
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page, 2.28,I Finally, with 0.064" average thickness remaining in the bay with the least margin (i.e.,
Bay 19), and AmerGen performing UT and visual inspections every four years, the drywell shell in Bay 19 could tolerate an average of 0.016" per year of corrosion over an area larger than nine square feet before violating the general average thickness.98 Such a corrosion rate, as demonstrated above, is simply speculation, and the frequency of AmerGen's visual and UT inspections make it impossible that such a condition would exist without AmerGen identifying it, L.
For all these reasons, a corrosion rate of 0.017" per year is simply speculation about future events that cannot be supported by realistic arguments or data. Accordingly, this second basis does not raise a genuine issue of material fact.
1).
Citizens' Allegation that a UT Monitoring Frequency of Once Per Year or More Is Necessary Presents No Genuine Issue of Material Fact The Board stated that, according to Citizens,."if corrosive conditions are possible, a UT monitoring fiequency of once per year or more would be necessary' to prevent violation of the acceptance criteria."'m0 Again, Citizens made this statement in their Supplement (at p. 9). The apparent basis is their belief that the drywell is within 0.026" or less from violating AmerGen's acceptance criteria and, at a rate of 0.017 inches per year, the acceptance criteria would be violated in less than two years. This argument does not raise a genuine issue of material fact because, as discussed above in Section V.B. and C., the supporting allegations concerning a in a 1.2" to 1.7-blister in the epoxy coating. That blister conservatively would be as thick as the following dashes are wide: -.---------------
LN The drywell shell would not collapse if such corrosion occurred. The acceptance criteria are based on the ASME Code which includes a safety factor of 2.0 for buckling under refueling conditions. In other words, the drywell shell would be twice as thick as it needed to be to prevent actual buckling, even under Citizens' hypothetical scenario.
2-9 The eight to ten year rated lifetime dIiscussed in Citizens' Exhibit 6 to their Original Petition is also simply incorrect. The multilayer epoxy coating is designed to withstand a submerged environment and to last for the life of the plant, provided that proper VT-I inspections are conducted and necessary corrective maintenance is performed to address any discrepancies found. Cavallo Affidavit, ¶ 23.
28
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 29 1 0.026" or less margin, and a 0.017" per year corrosion rate do not themselves raise a genuine issue of material fact.
E.
Citizens' Allegation that If the Next Scheduled UT Monitoring Shows that These Safety Margins Have Narrowed, then Even More Frequent Monitoring Would Be Needed Presents No Genuine Issue of Material Fact The Board also stated that, according to Citizens, "'if the next scheduled UT monitoring that is to occur before the end of the licensing period shows that these safety margins have narrowed, even more frequent monitoring would be needed. ""n-1 Clearly, this statement is no more than pure speculation about possible future UT results and cannot, by itself, create a genuine issue of material fiact. Moreover, AmerGen performed this "next scheduled UT monitoring" in October 2006, and Citizens did not seek to amend their admitted contention to incorporate those results. Therefore, the Board can dismiss this basis statement because it is procedurally moot.1-2 In any event, the UT data-coupled with the VT-I inspection from the October 2006 refueling outage-confirmed that corrosion on the exterior of the drywell shell has been arrested. o0 F.
Citizens' Allegation That UT Monitoring is Necessary Even Where Visual Inspections of the Epoxy Coating Do Not Reveal Coating Deterioration Presents No Genuine Issue of Material Fact The Board stated that, according to Citizens, '"UT monitoring is necessary even where visual inspections of the epoxy coating do not reveal that the coating has deteriorated, because I
LBP-06-22 (slip op. at 15).
~
Id.; see also Citizens' July 25 Supplement at 9.
cc I.BP-06-16, 63 N.R.C. at 745.
S Tamburro Affidavit at ¶ 41.
29
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 30 1
- 0. Asly-Sm ayDsislMto etadEhJ n
.d ae3 corrosion may occur under the epoxy coating in the absence of visible deterioration due to non-visible holidays, or pinholes'."'1 4 This allegation fails to raise a genuine issue of material fact because, as discussed above in Section V.B., any localized corrosion beneath "pinholes" or "holidays" would be compared to the 0.490" very local area average thickness criterion, not the 0.736" general area average thickness criterion. And there is adequate thickness remaining even in the thinnest location in the thinnest bay, at the speculative 0.017" per year corrosion rate to allow for a frequency of UT or visual inspections to occur more than every four years. Because AmerGen is perfonning visual and UT inspections every four years, this does not raise a genuine issue of material fact.L°5 L*-_
LBP-06-22 at 17; see also Citizens' Supplement at 12.
1 Although cited by the Board, AmerGen believes that this concern is outside the scope of the admitted contention. Citizens allege that "corrosion could occur below the damaged coating without being observed visually" (Citizens' Supplement at 12), and that "[hlolidays and pinholes in the coating cannot be assessed by 'visual examination"' (Dr. tausler July 25, 2006 Memorandum at 6). These allegations go to the adequacy of AmerGen's coatings monitoring program, an issue already excluded from the admitted contention by the Board.
30
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page,3.1 VI.
CONCLUSIONS The only admitted contention in this proceeding is based on speculation, misinterpretation of the governing acceptance criterion, and errors in math. These bases in no way raise a genuine issue as to any material fact. The Board should, therefore, grant summary disposition in AmerGen's favor and terminate the proceeding.
Respectfully submitted, Donald J. Silverman, Esq.
Kathryn M. Sutton, Esq.
Alex S. Polonsky, Esq.
MORGAN, LEWIS & BOCKIUS, LLP Il II Pennsylvania Avenue, N.W.
Washington, DC 20004 Phone: (202) 739-5502 E-mail: dsilverman{i0morganlewis.com E-mail: ksutton(amorganlewis.com E-mail: apolonskyvmorganlewis.com J. Bradley Fewell Associate General Counsel Exelon Corporation 4300 Warrenville Road Warrenville, IL 60555 Phone: (630) 657-3769 E-mail: Bradley.Fewell(cý.exeloncorp.com COUNSEL FOR AMERGEN ENERGY COMPANY, LLC Dated in Washington, D.C.
this 30th day of March 2007 31
I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 32,1 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD
)
In the Matter of:
AmerGen Energy Company, LLC (License Renewal for Oyster Creek Nuclear Generating Station)
)
_____)
March 30, 2007 Docket No. 50-219 CERTIFICATE OF SERVICE I hereby certify that copies of"AmerGen's Motion for Summary Disposition" were served this day upon the persons listed below, by E-mail and first class mail, unless otherwise noted.
Secretary of the Commission*
U.S. Nuclear Regulatory Commission Attn: Rulemakings and Adjudications Staff One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 (E-mail: HEARINGDOCKET(nrc.gov)
Administrative Judge Paul B. Abramson Atomic Safety and Licensing Board Panel Mail Stop - T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 (E-mail: pba(').nrc.gov )
Administrative Judge E. Roy Hawkens, Chair Atomic Safety and Licensing Boa~d Panel Mail Stop - T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 (E-mail: erh(canrc.gov)
Administrative Judge Anthony J. Baratta Atomic Safety and Licensing Board Panel Mail Stop - T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 (E-mail: aib5@nrc.gov)
I-WA/2725010
D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 33 I D. Ashley - Summary Dismissal Motion cert and Exhs 1 and 2.pdf Page 331 John A. Covino Valerie Anne Gray Division of Law Environmental Permitting and Counseling Section p.o. Box 093 Hughes Justice Complex Trenton, NJ 08625 (E-mail: john.covino('ddol.lps.state.ni.us)
(E-mail: Valerie.Grav dol.lps.state.ni.us)
Suzanne Leta NJPIRG 11 N. Willow Street Trenton, NJ 08608 (E-mail: sletainipirg.org)
Mitzi A. Young Steven C. Hamrick Jody C. Martin Office of the General Counsel, 0-15D21 U.S. Nuclear Regulatory Commission Washington, D.C. 20555 (E-mail: may nrc.gov)
(E-mail: schl (Qnrc.gov)
(E-mail: icm5(@nrc.gov)
Office of Commission Appellate Adjudication**
U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Richard Webster Rutgers Environmental Law Clinic 123 Washington Street Newark, NJ 07102-5695 (E-mail: rwebstertkinoy.rutgers.edu)
Paul Gunter Nuclear Information and Resource Service 1424 16th Street, NW Suite 404 Washington, DC 20036 (E-mail: pgunter@nirs.org)
Debra Wolf Law Clerk Atomic Safety and Licensing Board Mail Stop: T-3F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: dawl nrc.gov)
- Original and 2 copies
- First Class Mail only Alex S. Polonsky 2
[Exhibit i M l~xc!.
orn (oa~r A '-
Jr Ss/,
0~
_0 x
C-)
0 E
E C')
a)
U)
.Ei!.31 -_!,
-SEE DETAIL 'C' EL r~
Exhibil 2 A
3/4f'~n.,
LOW ER DRYWELL/SANDBED REGION PM--r.e
/E:
~LEAKAC; PAMI. FROM O071FR DETAIL C RYw,-. TO OUTER J*
- ]T::]}.::[,*ISANDRDE)
Sl ir~i
/
//
7q
/
iF
//
"N:~~i::iii:
. 2;
!]IS NIlfI FAR RFGI]I ATC)RY COMMISSION TN: DT-06-18 To:
NRC Management Directives Custodians Transmittal of Management Directive 8.7, Operating Experience Program"
Subject:
Purpose:
Office of Origin:
Contact:
Date Approved:
Volume:
Directive:
Availability:
"Reactor Directive 8.7 is being issued to provide agency-level guidance for the recently implemented Reactor Operating Experience (OpE) Program. The implementation of this new program is a result of recommendations from the Davis-Besse Lessons Learned Task Force (DBLLTF).
Office of Nuclear Reactor Regulation Carla P. Roquecruz, 301-415-1455 September 28, 2006 8
Licensee Oversight Programs 8.7 Reactor Operating Experience Program Rulemaking, Directives and Editing Branch Office of Administration Michael T. Lesar, 301-415-7163 Christy Moore, 301-415-7086 OFFICE OF ADMINIS TRA TION
D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 1 AmerGen...
10 CFR 50 10 CFR 51 10 CFR 54 2130-07-20464 February 15, 2007 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Oyster Creek Generating Station Facility Operating License No. DPR-16 NRC Docket No. 50-219
Subject:
Additional Commitments Related to the Aging Management Program for the Oyster Creek Drywell Shell, Associated with AmerGen's License Renewal Application (TAC No. MC7624)
References:
- 1. January 18, 2007 Meeting Between ACRS License Renewal Subcommittee, AmerGen Energy Company, LLC and NRC Staff, related to License Renewal of Oyster Creek Generating Station
- 2. February 1, 2007 Meeting Between Full ACRS, AmerGen Energy Company, LLC and NRC Staff related to License Renewal of Oyster Creek Generating Station
- 3.
ACRS Letter Dated February 8, 2007, Describing the Outcome of the February 1, 2007 ACRS Review of the Oyster Creek Generating Station License Renewal Application In the Reference 1 meeting, AmerGen Energy Company, LLC (AmerGen) presented detailed information related to the condition of and aging management program activities for the primary containment drywell shell, as part of AmerGen's efforts to renew the operating license for the Oyster Creek Generating Station (OCGS). The Subcommittee identified several specific issues related to the drywell shell structural analysis and certain aspects of the program proposed by AmerGen to manage aging of the drywell shell for the extended period of operation.
During the full ACRS review of the Oyster Creek License Renewal Application (LRA) in the Reference 2 meeting, AmerGen presented its proposed responses to the issues identified by the Subcommittee in the January 18, 2007 meeting. In its February 1st presentation, AmerGen made three additional commitments to address these previous Subcommittee items. This letter documents these commitments.
In addition, AmerGen is making a commitment to perform the full scope of drywell sand bed region inspections, consistent with what was performed during the 2006 refueling outage, on a frequency of every other refueling outage. AmerGen believes that this commitment is
I D. Ashley - Summary Dismissal - Exhibit 3.pdf DAshley - Summary Dismissal - Exhibit 3.pdf P~n#~ 2 IPaae 2
I February 15, 2007 Page 2 of 2 responsive to a recommendation made by NRC Staff at the February 1, 2007 ACRS meeting, which was endorsed by the ACRS in its February 8, 2007 letter to the NRC Chairman.
The details of these four new commitments are provided in the Enclosure to this letter. The ASME Section XI, Subsection IWE Primary Containment Inspection aging management program (commitment 27) is modified to include these new commitments, and to clarify the effect of these new commitments on previously made IWE program commitments.
If you have any questions, please contact Fred Polaski, Manager License Renewal, at 610-765-5935.
I declare under penalty of perjury that the foregoing is true and correct.
Respectfully, Executedoon
-o7 Michael P. Gallagher Vice President, License Renewal AmerGen Energy Company, LLC
Enclosure:
Regional Administrator, USNRC Region I USNRC Project Manager, NRR - License Renewal, Safety USNRC Project Manager, NRR - License Renewal, Environmental USNRC Project Manager, NRR - Project Manager, OCGS USNRO Senior Resident Inspector, OCGS Bureau of Nuclear Engineering, NJDEP File No. 05040
ý D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 3]
February 15, 2007 Enclosure Page 1 of 13 ENCLOSURE - REGULATORY COMMITMENTS The following table identifies additions being made to item #27 of the License Renewal Commitment List, Table A.5 of the Oyster Creek LRA. Four commitments are being added to the ASME Section XI, Subsection IWE Primary Containment Inspection Program as part of this submittal.
These new commitments are numbered to sequentially follow the commitments made in previous LRA correspondence as part of the IWE Inspection Program. The full set of commitments made as part of the IWE Program is repeated here for convenience. Bold font is used to highlight new information.
In addition, clarifications are made to certain previously made IWE Program commitments to indicate 1) commitments that were completed during the 2006 refueling outage and 2) the effects, if any, of the new commitments on the scope or frequency of previously made commitments. Again, bold font is used to highlight information introduced in this submittal.
UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION
_(LRA APP. A)
SCHEDULE Existing program is credited. The program will be A.1.27 Prior to the period of Section enhanced to include:
extended operation B.1.27
- 1. Ultrasonic Testing (UT) thickness measurements of Prior to the period of the drywell shell in the sand bed region will be extended operation performed on a frequency of every 10 years, except (completed during that the initial inspection will occur prior to the period 2006 refueling
- 27) ASME Section of extended operation and the subsequent outage); then every Xl, Subsection IWE inspection will occur two refueling outages after the other refueling initial inspection, to provide early confirmation that outage thereafter corrosion has been arrested. The UT measurements will be taken from the inside of the drywell at the same locations where UT measurements were performed in 1996.
The inspection results will be compared to previous results. Statistically significant deviations from the
D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 4 1 February 15, 2007 Enclosure Page 2 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION
_(LRA APP. A)
SCHEDULE 1992, 1994, and 1996 UT results will result in corrective actions that include the following:
Perform additional UT measurements to confirm the readings.
Notify NRC within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of confirmation of the identified condition.
Conduct visual inspection of the external surface in the sand bed region in areas where any unexpected corrosion may be detected.
Perform engineering evaluation to assess the extent of condition and to determine if additional inspections are required to assure drywell integrity.
Perform operability determination and justification for operation until next inspection.
These actions will be completed prior to restart from the associated outage.
Note: The frequency for the inspections described in commitment 1 (above) has been changed to every other refueling outage, in accordance with commitment 21 of the IWE Inspection Program.
- 2. A strippable coating will be applied to the reactor Refueling outages prior cavity liner to prevent water intrusion into the gap to and during the between the drywell shield wall and the drywell shell period of extended during periods when the reactor cavity is flooded, operation
I D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 5 February 15, 2007 Enclosure Page 3 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION ILRAAPP. A)
SCHEDULE
- 3. The reactor cavty seal leakage trough drains andy Periodically the drywell sand bed region drains will be monitored for leakage.
The sand bed region drains will be Daily during refueling monitored daily during refueling outages outages. If leakage is detected, procedures will be in place to determine the source of leakage and investigate and address the impact of leakage on the drywell shell, including verification of the condition of the drywell shell coating and moisture barrier (seal) in the sand bed region and performance of UT examinations of the shell in the upper regions. UTs will also be performed on any areas in the sand bed region where visual inspection indicates the coating is damaged and corrosion has occurred.
UT results will be evaluated per the existing program. Any degraded coating or moisture barrier will be repaired.
These actions will be completed prior to exiting the associated outage.
- The sand bed region drains will be Quarterly during non-monitored quarterly during the plant outage periods operating cycle. If leakage is identified, the source of water will be investigated, corrective actions taken or planned as
I D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 6 February 15, 2007 Enclosure Page 4 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION (LRAAPP. A)
SCHEDULE appropriate. In addition, if leakage is detected, the following items will be performed during the next refueling outage:
Inspection of the drywell shell coating and moisture barrier (seal) in the affected bays in the sand bed region UTs of the upper drywell region consistent with the existing program UTs will be performed on any areas in the sand bed region where visual inspection indicates the coating is damaged and corrosion has occurred UT results will be evaluated per the existing program Any degraded coating or moisture barrier will be repaired.
- 4. Prior to the period of extended operation, AmerGen Prior to the period of will perform additional visual inspections of the extended operation epoxy coating that was applied to the exterior (completed during surface of the Drywell shell in the sand bed region, 2006 refueling such that the coated surfaces in all 10 Drywell bays outage); then every will have been inspected at least once. In addition, otherrefueling the Inservice Inspection (ISI) Program will be outagethereafter enhanced to require inspection of 100% of the epoxy coating every 10 years during the period of
I D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 7 1 February 15, 2007 Enclosure Page 5 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION (LRA APP. A)
SCHEDULE extended operation. These inspections will be performed in accordance with ASME Section XI, Subsection IWE. Performance of the inspections will be staggered such that at least three bays will be examined every other refueling outage.
Note: The scope and frequency forthe inspections described in commitment4 (above) has been changed to all 10 bays every other refueling outage, in accordance with commitment2l of theIWE Inspection Program.
- 5. A visual examination of the drywell shell in the Prior to the period of drywell floor inspection access trenches will be extended operation performed to assure that the drywell shell remains (completedduring intact. If degradation is identified, the drywell shell 2006 refueling condition will be evaluated and corrective actions outage) taken as necessary.
In addition, one-time ultrasonic testing (UT) measurements will be taken to confirm the adequacy of the shell thickness in these areas.
Beyond these examinations, these surfaces will either be inspected as part of the scope of the ASME Section X1, Subsection IWE inspection program or they will be restored to the original design configuration using concrete or other suitable material to prevent moisture collection in these areas.
Note: Commitment 5 (above) is supplemented by
D. Ashley - Summary Dismissal - Exhibit 3.pdf Page.8.]
February 15, 2007 Enclosure Page 6 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENTOR SOURCE LOCATION IMPLEMENTATION
_(LRA APP. A)
SCHEDULE commitments16 and 20 of the IWE Inspection Program.
- 6. The coating inside the torus will be visually Every other refueling inspected in accordance with ASME Section Xl, outage prior to Subsection IWE, per the Protective Coatings (completed during Program. The scope of each of these inspections 2006 refueling will include the wetted area of all 20 torus bays.
outage) and during the Should the current torus coating system be period of extended replaced, the inspection frequency and scope will, operation as a minimum, meet the requirements of ASME Section XI, Subsection IWE.
- 7. AmerGen will conduct UT thickness measurements Every other refueling in the upper regions of the drywell shell every other outage prior to refueling outage at the same locations as are (completed during currently measured, 2006 refueling outage) and during the period of extended operation
- 8. The IWE Program will be credited for managing corrosion in the Torus Vent Line and Vent Header exposed to an Indoor Air (External) environment.
- 9. During the next UT inspections to be performed on Prior to the period of the drywell sand bed region (reference AmerGen extended operation 4/4/06 letter to NRC), an attempt will be made to (completed during locate and evaluate some of the locally thinned 2006 refueling
0 D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 9 February 15, 2007 Enclosure Page 7 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION
_LRA APP. A)
SCHEDULE areas identified in the 1992 inspection from the outage);then every exterior of the drywell. This testing will be otherrefueling performed using the latest UT methodology with outage thereafter existing shell paint in place. The UT thickness measurements for these locally thinned areas may be taken from either inside the drywell or outside the drywell (sand bed region) to limit radiation dose to as low as reasonably achievable (ALARA).
Note: Commitment9 (above) is supplemented by commitments14 and 21 of the IWE Inspection Program.
- 10. AmerGen will conduct UT thickness measurements Prior to the period of on the 0.770 inch thick plate at the junction between extended operation the 0.770 inch thick and 1.154 inch thick plates, in and two refueling the lower portion of the spherical region of the outages later drywell shell. These measurements will be taken at four locations using the 6"x6" grid. The specific locations to be selected will consider previous operational experience (i.e., will be biased toward areas that have had corrosion or leakage). These measurements will be performed prior to the period of extended operation and repeated at the second refueling outage after the initial inspection, at the same location. If corrosion in this transition area is greater than areas monitored in the upper drywell, UT inspections in the transition area will be performed on the same frequency as those in the
D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 10t February 15, 2007 Enclosure Page 8 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION (LRA APP. A)
SCHEDULE upper drywell (every other refueling outage).
- 11. AmerGen will conduct UT thickness measurements Prior to the period of in the drywell shell "knuckle" area, on the 0.640 inch extended operation thick plate above the weld to the 2.625 inch thick and two refueling plate. These measurements will be taken at four outages later locations using the 6"x6" grid. The specific locations to be selected will consider previous operational experience (i.e., will be biased toward areas that have had corrosion or leakage). These measurements will be performed prior to the period of extended operation and repeated at the second refueling outage after the initial inspection, at the same location. If corrosion in this transition area is greater than areas monitored in the upper drywell, UT inspections in the transition area will be performed on the same frequency as those in the upper drywell (every other refueling outage).
- 12. When the sand bed region drywell shell coating Prior to the period of inspection is performed (item 27, commitments 4 extended operation and 21), the seal at the junction between the sand (completed during bed region concrete and the embedded drywell shell 2006 refueling will be inspected per the Protective Coatings outage);then every Program.
other refueling Note: The frequency forthe inspections outagethereafter described in commitment 12 (above) has been I
changed to every other refueling outage, in I
II I
I D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 11 I February 15, 2007 Enclosure Page 9 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION (LRA APP. A)
SCHEDULE accordance with commitment2l of the IWE Inspection Program.
- 13. The reactor cavity concrete trough drain will be Once per refueling verified to be clear from blockage once per refueling cycle cycle. Any identified issues will be addressed via the corrective action process.
- 14. UT thickness measurements will be taken from During the 2008 outside the drywell in the sandbed region during the refueling outage and 2008 refueling outage on the locally thinned areas every other refueling examined during the October 2006 refueling outage.
outage thereafter The locally thinned areas are distributed both vertically and around the perimeter of the drywell in all ten bays such that potential corrosion of the drywell shell would be detected.
Note: The frequency for the inspections described in commitment 14 (above) has been changed to every other refueling outage, in accordance with commitment2l of the IWE Inspection Program.
- 15. Starting in 2010, drywell shell UT thickness All 10 bays will be measurements will be taken from outside the drywell inspected during the in the sandbed region in two bays per outage, such 2008 refueling outage that inspections will be performed in all 10 bays and every other
D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 121 February 15, 2007 Endosure Page 10 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION (LRA APP. A)
SCHEDULE within a 10-year period. The two bays with the most refueling outage locally thinned areas (bay #1 and bay #13) will be thereafter.
inspected in 2010. If the UT examinations yield unacceptable results, then the locally thinned areas in all 10 bays will be inspected in the refueling outage that the unacceptable results are identified.
Note: The scope and frequencyfor the inspections described in commitment15 (above) have been changed to all 10 bays every other refueling outage, in accordance with commitment 21 of the IWE Inspection Program.
- 16. Perform visual inspection of the drywell shell inside During the 2008 the trenches in bay #5 and bay #17 and take UT refueling outage and measurements inside these trenches in 2008 at the subsequent refueling same locations examined in 2006. Repeat (both the outages until trenches UT and visual) inspections at refueling outages are restored to original during the period of extended operation until the configuration trenches are restored to the original design configuration using concrete or other suitable material to prevent moisture collection in these areas.
Note: Commitment16 (above) is supplemented by commitment20 of the IWE Inspection Program.
I D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 131 February 15, 2007 Enclosure Page 11 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENTOR SOURCE LOCATION IMPLEMENTATION (LERA APP. A)
SCHEDULE
- 17. Perform vsual inspection of the moisture barrier In accordance with between the drywell shell and the concrete ASME Section XI, floor/curb, installed inside the drywell during the Subsection IWE October 2006 refueling outage, in accordance with ASME Section Xi, Subsection IWE during the period of extended operation,
- 18. AmerGen will perform a 3-D finite element Prior to the period of structural analysis of the primary containment extended operation drywell shell using modern methods and current drywell shell thickness data to betterquantify the margin that exists above the Code required minimum for buckling. The analysis w ill include sensitivity studies to determine the degree to which uncertainties in thesize of thinnedareas affect Code margins. If the analysis determines that the drywell shell does not meet required thickness values, the NRC will be notified in accordance with 10 CFR 50 requirements.
- 19. AmerGen will perform an engineering studyto Prior to the period of investigate cost-effective replacement or repair extended operation options to eliminate or reduce reactor cavity liner leakage.
- 20. AmerGen is committed to perform visual and UT Every refueling inspections of the dryw ell shell in the inspection outage until trenches trenches in drywell bays 5 and 17 during the are restored
I D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 141 February 15, 2007 Enclosure Page 12 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION (LRAAPP. A)
SCHEDULE Oyster Creek 2008 refueling outage (see commitment'16 of AmerGen's IWE Program (item 27), made in its letter 2130-06-20426).
AmerGen will extend this commitment and also perform these inspections during the 2010 refueling outage. In addition, AmerGen will monitorthetwo trenches for the presence of water during refueling outages. Visual and UT inspections of the shell within the trenches will continueto be performed until no water is identified in the trenches for two consecutive refueling outages, at which timethe trenches will be restored to theiroriginal design configuration (e.g., refilled with concrete) to minimize the risk of future corrosion.
- 21. Perform the full scope of drywell sand bed During the 2008 region inspections prior to the period of refueling outage and extended operation and then every other every other refueling refueling outage thereafter. The full scope is outagethereafter. If defined as:
the analysis being UT measurements from inside the drywell performed under (commitment1) commitment 18
- Visual inspections of the drywell external above establishes shell epoxy coating in all 10 bays increased margin, or (commitment4) if ongoing
- Inspection of theseal at thejunction inspections continue between the sand bed region concrete and to demonstrate that the embedded drywell shell (commitment drywell shell
D. Ashley - Summary Dismissal - Exhibit 3.pdf Page 151 February 15, 2007 Enclosure Page 13 of 13 UFSAR ITEM NUMBER COMMITMENT SUPPLEMENT ENHANCEMENT OR SOURCE LOCATION IMPLEMENTATION (LRA APP. A)
SCHEDULE
- 12) corrosion has been LUT measurements at the external locally sufficiently arrested, thinned areas inspected in 2006 the period between (commitments 9 and 14) inspections may be increased to minimize personnel radiation exposure.
Page 1]
- 0. Ashley - Summary Dismissal Supporting Affidavits.pdf Pae UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD Before Administrative Judges:
E. Roy Hawkens, Chair Dr. Paul B. Abramson Dr. Anthony J. Baratta In the Matter of:
AmerGen Energy Company, LLC (License Renewal for Oyster Creek Nuclear Generating Station)
Docket No. 50-219 AFFIDAVIT OF PETER TAMBURRO Lacey Township
))
State of New Jersey Peter Tamburro, being duly sworn, states as follows:
INTRODUCTION
- 1.
This Affidavit is submitted to support AmerGen Energy Company, LLC's Motion for Summary Disposition on the contention filed by environmental and citizen groups ("Citizens") opposed to the renewal of the Oyster Creek Nuclear Generating Station ("OCNGS") operating license, and admitted by the Licensing Board on October 10, 2006.
- 2.
The contention, as admitted by the Licensing Board states: "AmerGen's scheduled [ultrasonic testing ("UT")] monitoring frequency in the sand bed region is insufficient to maintain an adequate safety margin." The purpose of my
D. Ashley - Summary Dismissal Supporting Affidavits.pdf
.Page 2
Affidavit is to address Citizens' allegations regarding the frequency of AmerGen's UT measurements.
- 3.
It is my expert opinion that these allegations have no technical merit because they are based on a misinterpretation of the governing thickness criteria, calculation errors, and speculation about future conditions.
- 4.
It is also my opinion that the frequency of UT of the sand bed region of the dry-well shell reflected in AmerGen's existing commitments to the NRC is sufficient to provide reasonable assurance that the applicable thickness acceptance criteria will be met, that an adequate safety margin will be maintained during the period of extended operation under a renewed license, and that the drywell will continue to serve its intended functions.
EDUCATION AND EXPERIENCE
- 5. 1 received my B.S. degree in Chemical Engineering from Clarkson University, Potsdam, New York, in 1980. I received my M.S. in Computer Science from Fairleigh Dickinson University, Teaneck, New Jersey, in 1986. 1 first registered as a Professional Engineer in the State of New Jersey around 1986.
- 6. I currently am employed as Senior Mechanical Engineer in the Engineering Department at the Oyster Creek Nuclear Generation Station. My current responsibilities include:
" Implementing the above-and below-ground piping monitoring program to ensure piping is capable of performing its intended function. This includes maintaining operating history, risk-ranking plant piping systems, establishing inspection scope and criteria, analyzing inspection results, sponsoring modification and replacement based on inspection results, and overseeing the design and 2
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 3 installation of new piping systems. My responsibilities also include the temporary and permanent repair of piping leaks at OCNGS.
> Implementing the OCNGS Drywell Vessel Monitoring Program. This program ensures that the Drywell Vessel (a.k.a. "shell") is inspected consistent with current regulatory commitments, This includes setting scope for future inspections and analysis of inspection results.
- 7. My past responsibilities included designing and implementing modifications at OCNGS. This included new below-and above-ground piping from 1992 to 2006, and engineering oversight and implementation of all Security Upgrades at the plant from 1998 to 2006.
- 8. I am very familiar with the historical corrosion of the OCNGS drywell shell. My involvement began in 1988 when I took over the responsibility for "10 CFR 50.59" Evaluation of the issue. This included comparing the design requirements of the shell with the inspection results. This also included setting the outage-related inspection scope, and reporting to the NRC throughout that time period on the results of those inspections.
- 9. Since 1996, 1 have been responsible for ensuring upper drywell inspections are performed every other outage. I have also analyzed those inspection results.
- 10. With respect to license renewal, I have provided historical perspective on drywell corrosion, corrective actions, and inspection. I reviewed and commented on the drywell-related portions of the OCNGS License Renewal Application ("LRA")
submitted to the NRC on July 22, 2005, and the LRA supplement submitted to the NRC on December 3, 2006.
3
D. Ashley-Summary Dismissal Supporting Affidavits.pdf
"...,.*........Page 4
II. I supported the NRC license renewal audits and inspections in 2006 as the lead engineer responsible for drywell-related inspections. I supported the response to the NRC Staff's requests for additional information.
- 12. 1 assisted in developing the inspection scope for the October 2006 refueling outage, and I analyzed all inspection results.
- 13. 1 also participated, as a site engineer knowledgeable about drywell issues, in meetings with the Advisory Committee on Reactor Safeguards (ACRS) on October 3, 2006, January 18, 2007 and February 1,. 2007.
OPINIONS OF PETER TAMBURRO I.
Citizens' Allegation of 0.026" Remaining Margin Is Technically Unsupportable
- 14. I understand that Citizens have asserted that the drywell shell in the sand bed region is 0.026" or less away from exceeding the acceptance criteria for buckling developed by GE Nuclear in the early 1990s. As I explain below, this assertion is based on a misinterpretation of the 0.536" local area average thickness criterion.
- 15. By way of background, the acceptance criteria for the drywell shell in the Oyster Creek sand bed region are the minimum thicknesses required for the drywell to perform its intended functions. GE Nuclear analyses established these criteria in 1991 and 1992, and they form part of the Oyster Creek current licensing basis.
- 16. Before the sand was removed from the sand bed region, GE Nuclear performed an engineering analysis of the drywell shell to determine whether historical corrosion prevented the drywell from performing its intended functions. GE Nuclear conducted this analysis in 1991, based on ASME Code requirements, to establish the minimum 4
Page 5]
r~ A..kI~,, - ~
fliQmie~d.~iinnr~rtinci Affir1~vitsndf Page 5 required general thickness, with the sand removed, for both pressure and buckling stresses.
- 17. The results of GE Nuclear's analysis show that the minimum required thickness in the sand bed region is controlled by buckling. By "controlled", I mean that for the analyses performed to model design conditions that might lead to structural degradation, the analysis for buckling showed the least margin. Moreover, a general thickness of 0.736" will satisfy ASME Code requirements with a safety factor of 2.0 against buckling for the controlling operating load combination (i.e., during refueling), and 1.67 safety factor for the accident flooding load combination (i.e,,
during operations).
- 18. At that time, a "very local" area thickness of 0.490", not to exceed 2.5 inches in diameter, was also identified. This "very local" thickness criterion is relevant to Citizens' argument about pinholes or holidays, which I discuss in paragraphs 42 and 43, below. However, it is not pertinent to Citizens' argument about 0.026" remaining margin, as I discuss below.
- 19. In 1992, GE Nuclear performed a series of sensitivity analyses on the original 0.736" criterion. These analyses sequentially evaluated locally-thinned areas using one square foot areas of 0.636" and 0.536", each with a transition to the surrounding shell at a uniform thickness of 0.736". Since Dr. Hausler only references the 0.536" analysis, I will discuss only that analysis.
- 20. Thus, there are two criteria relevant to Citizens' argument. The first criterion is a general average thickness of 0.736". An area of average thickness less than 0.736" remains adequate if it meets the second criterion, which is the 0.536" local area average thickness, and other factors such as location, configuration, etc. This local 5
- 'age o
D. Ahle - ummry DsmisalSuportng Afidvit~pd iPage 6 area criterion includes a one-foot transition area to 0.736" on all four sides of the 0.536" area, such that the total allowable contiguous area with thickness below 0.736 is nine square feet. This is clearly shown on Figure 1 which I created, and which is based on the GE Nuclear report that was attached to the AmerGen submittal to the ACRS on December 8, 2006, as Reference 22.
- 21. Dr. Hausler interprets the local area criterion as being exceeded if the area thinner than 0.736" is greater than one square foot. He states in his June 23, 2006, memorandum that an area "approximately 1.6 square feet" thinner than 0.736" would be "well beyond the current acceptance criterion." This statement can only be based on a misunderstanding of the local area thickness criterion, which allows for nine square feet.
- 22. Dr. Hausler's misunderstanding seems to stem from his belief that the local area acceptance criterion is configured with an abrupt step-change (like a cliff) on all sides of the one square foot area that averages 0.536", such that the thickness increases to 0.736" with no transition. See Figure 2.
- 23. Thus, even if an area of approximately 1.6 square feet thinner than 0.736" existed, the local area acceptance criterion still would not be exceeded because that criterion allows for an area thinner than 0.736" of nine square feet.
- 24. The actual bounding general average thickness in the sand bed region is 0.800" located in Bay 19, which leaves a margin of 0.064" when compared to the 0.736" general area thickness criterion, not 0.026". All the other bays have greater margin, ranging from 0.074" in Bay 17, to 0.439" in Bay 3. The thinnest local measurement identified by Dr. Hausler was 0.618" located in Bay 13. This leaves a margin of 0.082" when compared to the 0.536" local area thickness criterion.
6
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page7
- 25. Citizens' assertion that the margin above the acceptance criteria is as low as 0.026",
therefore, is not supported by the data.
- 26. The entirety of Dr. Hausler's argument about the 0.026" of metal thickness can be found on page 7 of his June 23, 2006 memorandum. I will now walk through Dr.
Hausler's argument and demonstrate that in addition to misinterpreting the local area acceptance criterion as one square foot, his calculations also are wrong. In order to argue that this criterion will be exceeded in the future, he takes a thin point in Bay 13, and makes an assumption that future corrosion will increase the area around this point such that the area will be larger than one square foot. In other words, he speculates that corrosion-which cannot occur while the epoxy coating is intact-will make the thinned area wider.
- 27. Dr. Hausler bases his conclusion about 0.026" on the UT data collected from single measurement points on the exterior of the drywell shell in the sand bed region in Bay 13 in 1992.
- 28. In general, the drywell shell in the sand bed region of Bay 13, prior to 1992, experienced a significant amount of corrosion from the presence of wetted sand. In that bay, the corrosion caused the formation of indentations in a pattern visually similar to the surface of a golf ball. In 1992, before the exterior drywell shell was coated with epoxy, UT measurements showed that the thinnest of these indentations averaged approximately 0.800" in thickness.
- 29. In 1992, Bay 13 had nine, locally-thin areas less than 0.736". By "locally-thin", I mean the area was less than 2.5" in diameter. The thinnest of these locally thin areas is referred to as "point 7" which had the single thinnest reading of 0.618". Around 7
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page.
this point, the evaluation of the data from 1992 found a larger 6" by 6" square area that averaged at least 0.677" thick.
- 30. On page 7 of his June 23, 2006 memorandum, Dr. Hausler states that the total area less than 0.736" at "point 7", referring to the area which averages 0.677", is 0.3 square feet. Although the 1992 Oyster Creek reports describe this area as a 6" by 6" square area, Dr. Hausler elects to convert this area into a circular area. The corresponding radius of the circular area, which is 0.3 feet square, is 3.7 inches.
I have created Figure 2 to show a profile representing these measurements.
- 31. Dr. Hausler's next statement is an assumption that is not supported by the data.
Dr. Hausler states on page 7 of his June 23, 2006 memorandum that "this area is very sensitive to corrosion because in a length of around 5 inches, the thickness changed from around 0.736 inches to 0.800 inches. Assuming the edge of the hole is a straight line, this means that a change of 0.064 inches in depth occurs over about 5 inches in length." Dr. Hausler assumes that the transition from the thinner area less than 0.736" to areas that are 0.800" or thicker is 5" long (radially). As I said, this assumption is not supported by the data. However, if you construct a model of a hypothetical indentation as described in this unsupported assumption using the 5" transition zone and the corresponding inner radius of the 3.7", the total radius of the model is 8.7" or 17.4" in diameter. Figure 2 also shows this configuration.
- 32. Dr. Hausler continues with his unsupported assumptions. He concludes that "[tWhus, for the radius of the thin area to change by two inches, the depth would have to change by only 0.026"." The statement that the radius would change 2" can only be an assumption because such a change could only occur through corrosion, and corrosion on the exterior of the drywell shell in the sand bed region has been arrested.
8
Hage u I II r Achlcý
- Suimmary, Dismkisa Siinnortino Affidavits.Ddf l'g Regardless, by expanding the radius of the indentation by 2", the diameter of the indentation would increase by 4", for a total diameter of 21.7" (this is larger than Dr. Haulser's memo which mentions 17.4" diameter). I have created Figure 3 to show the increase of the radius of the hypothetical indentation by 2".
- 33. Dr. Hausler then mistakenly concludes that if the 2" radius expansion occurred, then "the total area below 0.736 inches would be approximately 1.6 square feet, well beyond the current acceptance criterion." This conclusion is misleading for a number of reasons.
- 34. First, this conclusion is proved false by Dr. Hausler's own model. The radius of the expanded area less than 0.736" (shown on Figure 4) is 5.7". Simply calculating the area of a 5.7" radius circle results in 0.709 square feet. This value is significantly less than the 1.6 square foot value that Dr. Hausler offers.
- 35. Second, Dr. Hausler underestimates how much metal needs to corrode to meet his (incorrect) definition of the local area acceptance criterion. The radius of a 1.6 square foot circle is approximately 8.6". As I explain in 131 above, Dr. Hausler uses 8.7" for this value rather than 8.6". See Figure 2. In my opinion, by arriving at his conclusion that a 1.6 square feet area is less than 0.736", Dr. Hausler has made another assumption that the entire original 17.4" diameter indentation is less than 0.736".
This assumption would require an additional section of material, 0.033" deep to simply disappear (see Figure 5). Assuming this metal disappeared through corrosion, this corrosion would be in addition to the 0.026" of corrosion that Dr. Hausler hypothesizes. I have created Figure 5 to show the material that would need to disappear (see area designated as "Second Assumed Material Loss").
9
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 10
- 36. Finally, as I state above, Dr. Hausler then misinterprets the local area acceptance criterion by assuming that an area of one square foot that is thinner than 0.736" exceeds that criterion. He is wrong and I have created Figure 6 to show how the additional corrosion that Dr. Hausler postulates would not exceed the local area thickness criterion. In Figure 6, 1 have reproduced the acceptance criteria profile from Figure 1, and overlaid Dr. Hausler's assumed contour from Figure 5. The new Figure clearly shows that the acceptance criterion is not exceeded.
- 11.
A Future 0.017" Annual Corrosion Rate Is Also Technically Unsupportable
- 37. Citizens next argue that corrosion rates around 0.0 17" per year have been observed.
Corrosion rates in the range of.017" per year were observed in the sand bed region prior to 1992. Those rates were developed based upon UT data gathered between 1987 and 1992.
- 38. If Citizens are suggesting that a corrosion rate of 0.017" per year continued to occur after removal of the sand in 1992, or could occur in the future, they are incorrect for numerous reasons.
- 39. First, such an allegation ignores corrective actions implemented to date. Much has happened to prevent corrosion from continuing in the sand bed region of the drywell shell. The source of water-the flooded reactor cavity liner during refueling outages-has been identified and controlled. No water is expected to reach the sand bed region when strippable coating is applied to the reactor cavity during refueling outages. Even if some water did reach the sand bed region during refueling outages, the sand has been removed so there is no media to physically hold the water against the drywell shell's exterior. And the historic corrosion occurred because the drywell 10
1 D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 11 1 D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 11 I shell in the sand bed region was not coated. The exterior shell is now protected by a three-layer epoxy coating.
- 40. Second, if a corrosion rate of 0.017" per year had occurred between 1992 and 2006, it would have been readily detected by the VT-1 and UT performed during the 2006 refueling outage. VT-1 inspections are visual inspections performed in accordance with ASME Section XI subsection IWE, by ASME-qualified inspectors. Based on the information contained in the VT-I inspection reports generated for the coating in all ten external drywell bays during the October 2006 outage, the epoxy coating is in good condition with no defects or deterioration.
- 41. AmerGen also collected UT measurement data from both the interior and exterior of the drywell shell in the sand bed region during the 2006 refueling outage. Between 1992 and 2006, the alleged rate of corrosion of 0.017" per year would have resulted in a loss of 0.238" of metal from the drywell shell (0.017" x 14 years), which would easily have been detected, as it is well within the expected equipment measurement error of 0.020". Yet the UT data, coupled with the VT-I inspection results, confirmed that corrosion on the exterior of the drywell shell has been arrested.
- 42. Third, even if there was a 0.017" per year corrosion rate, Citizens only have argued that it would be localized. Specifically, Dr. Hausler, in his July 2006 memorandum, speculates that there might be tiny holes-"pinholes" or "holidays"-in the epoxy coating which could allow water to contact the exposed shell in the pinhole or holiday, causing very localized corrosion.
II
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 12 SD. Ashley - Summary Dismissal Supporting Affidavit's.pdif Page 12.I
- 43. Such very localized corrosion would not call into question the appropriateness of AmerGen's UT frequency. Pinholes and holidays are analyzed against the "very local" area acceptance criterion of 0.490" which applies to areas not to exceed 2.5 inches in diameter. The thinnest external point measurement identified by Dr.
Hausler was 0.618" located in Bay 13. Simple math demonstrates that there is 0.128" of margin available for a pinhole or holiday in this thinned area in Bay 13 (i.e.,
0.618"-0.490"), and that it would take over seven years for this margin to disappear with a corrosion rate of 0.017" per year (i.e.. 0.128"/0.017"). AmerGen, however, is performing UT measurements and visual inspections of the drywell shell in the sand bed region, from internal and external locations, in 2008 and then every four years.
I declare under penalty of perjury that the foregoing affidavit and the matters stated therein are true and correct to the best of my knowledge, information, and belief.
Peter Tamburro Oyster Creek Nuclear Generating Station Route 9 Forked River, NJ 08731 Subscribed and sworn before me this k day of March 2007.
Notary Public VALERIE LAUDEMAN My Comnission Expires:I 12
Figure 1 Schematic Demonstrating Local Area Average Acceptance Criterion CD cn C
3 0)
(n C"
0, (0
12" }
12" {
12" {
>. 0.536"1 Transition from 0.536"to 0.736" i
I Plan 0.736" 0.536"
~-----
fo Transition from
(<
> (E
<---0.536"to 0.736" 12" 6"
over a 12" length Profe12" Profile Not to Scale
Figure 2 Centerline of circular indentation at point 7 as postulated by Dr. Hausler Dr. Hausler's assumption that the transition from
.736" to.800" occurs over a 5 inch length CD' C
3 C,'
C-o 0
(0 Q-C,'
.800"
.736" "064'{
Thickness
.677" I
.618"1----------
3.7" 5"
8.7" Not to Scale Profile CD 4ý-
Figure 3 Cn CD Cn Cd, 0)
Assumption that the transition from
.736" to.800" occurs over a 5 inch length Not credible assumption that the entire
/indentation grows by 2" in radius
.800"
.064" :
.736"
.026"
.677" 2"
2" Contour of expanded area Profile
.677" 3.7" 9
5,,
Not to Scale
Figure 4 Increase in depth due to expansion by 2" 8.7" 2"1
.800"1
.736"1.0 Expanded area I ;s than 0.736 thick 4
First Assumed Material Loss (between arrows)
.677"
.033" 1
Contour of expanded area rýz 3.7" 2"
3, 2,
Profile Radius of expanded area less than 0.736 inches thick (Area of this circle is 0.709 feet square)
Not to Scale
Figure 5 8.7" 0
('
D,)
CD Bn C
3 3
Cn
'0 (0
0' (0
Assumption that this area also corroded to less than 0.736 inches Radius of the original indentation (See Figure 2)
.800" I.064"
.09"[
1.026"
.033"
.677"'............
Not to Scale 2"
2" Second Assumed Material Loss
.736" (between arrows) i Contour of assumed area less than 0.736 inches 3.7" 2"
2.9" 2"
Profile 8.6" radius = 1.6 square toot circle
Figure 6 (D
(/2 C
3 3
_0
'0
~0 a
8.6" Contour Assumed by Dr. Hausler
.736"
.677"
- Contour representing Local Area
!Average Acceptance Criterion i
.536" 6"
12" 8.6" Not to Scale Profile
D. Ashley - Summary Dismissal Supporting AfdvspfPae19]
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD Before Administrative Judges:
E. Roy Hawkens, Chair Dr. Paul B. Abramson Dr. Anthony J. Baratta In the Matter of:
AmerGen Energy Company, LLC (License Renewal for Oyster Creek Nuclear Generating Station)
Docket No. 50-219 AFFIDAVIT OF BARRY GORDON City of San Jose
)
State of California Barry Gordon, being duly sworn, states as follows:
INTRODUCTION I
This Affidavit is submitted to support AmerGen Energy Company, LLC's Motion for Summary Disposition on the contention filed by environmental and citizen groups
("Citizens") opposed to the renewal of the Oyster Creek Nuclear Generating Station
("OCNGS") operating license, and admitted by the Licensing Board on October 10, 2006. That contention challenges the frequency of AmerGen's UT measurements of the drywell shell in the sand bed region. In part of their contention, Citizens speculate that significant corrosion of the exterior of the OCNGS drywell shell in the sand bed region could occur through tiny defects (called "pinholes" or holidays") in
I D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 20 the three-layer epoxy coating system: "corrosion may occur under the epoxy coating in the absence of visible deterioration due to non-visable holidays, or pinholes."
- 2. As I discuss below, it is my expert opinion that these allegations have no technical merit because: (a) significant corrosion is not possible with an epoxy-coated drywell shell; and (b) even if such a corrosion rate was possible, AmerGen's committed frequency of UT measurements is more than adequate to detect such corrosion (even under unrealistic assumptions), before the ASME Code-specified margins are exceeded. Accordingly, Citizens' argument is not only factually irrelevant but simply immaterial to the integrity of the drywell shell during the proposed period of extended operation.
EDUCATION AND EXPERIENCE
- 3. For the past 38 years, I have been an engineer focusing on corrosion and material issues in light-water reactors, with special emphasis on stress corrosion cracking (SCC). I have addressed numerous materials and corrosion issues in the nuclear industry in a wide range of contexts including reactor internals, piping, fuel hardware, water chemistry transient and core flow issues, weld overlays and repairs, crack growth rate modeling, alloy selection, failure analysis, license renewal, NRC inspection relief, dry fuel storage, and decontamination.
- 4. I received my B.S. and MS. degrees in Metallurgy and Material Science from Carnegie Mellon University in 1969 and 1971, respectively. Since then, I have completed additional courses from MIT., the University of Pittsburgh and the National Association of CoTosion Engineers (NACE) in Corrosion Science.
2
I D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 2-1 1
- 5. 1 am a Registered Professional Engineer in Corrosion Engineering in the State of California (4208), a Registered Corrosion Specialist with NACE International
(#1986) and a Member of the International Cooperative Group on Environmentally Assisted Cracking (ICG-EAC).
- 6. 1 was certified as an Instructor for the International Atomic Energy Agency (IAEA) on February 2001 and am an Adjunct Professor at the Colorado School of Mines, in Golden, Colorado where I currently supervise one Ph.D candidate. I teach the following course: "Corrosion and Corrosion Control in LWRs" for Structural Integrity Associates, Inc. and have taught "Corrosion and Corrosion Control in BWRs" for GE Nuclear Energy (GENE). I have held instructor credentials for Engineering in California Community Colleges since 1986.
- 7. From 1969 to 1975, I was employed as a materials engineer by Westinghouse Electric at the Bettis Atomic Power Laboratory, located in West Mifflin, Pennsylvania.
- 8. From 1975 to 1998, 1 was employed by GE Nuclear Energy, located in San Jos&,
California. While at GE Nuclear Energy, I was a technical expert in corrosion engineering, a project manager in corrosion technology, and a program manager in stress corrosion cracking.
- 9. Since 1998, 1 have been employed by Structural Integrity Associates, Inc., also located in San Jos6, California, as an Associate.
- 10. 1 am familiar with the historical corrosion of the OCNGS drywell shell because I started working on that issue in 1986 as the OCNGS drywell project manager when I was employed by GENE.
3
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page
.1 D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 22
- 11. More recenily, I prepared an evaluation report on the corrosion of steel embedded in concrete on the exterior of the drywell (June 5, 2006) and on effects of water on corrosion propensities of concrete embedded steel identified in the interior of the drywell (November 3, 2006). 1 also testified before the Advisory Committee on Reactor Safeguards (ACRS) on both subjects on January 18, 2007.
OPINIONS OF BARRY GORDON
- 12. In his June 23, 2006, memorandum, Dr. Rudolf Hausler suggests that a future corrosion rate of 0.017" per year is possible for the external surface of the drywell shell in the sand bed region at OCNGS. He correctly asserts that this corrosion rate was observed by the former owner of the OCNGS in certain areas of the sand bed region prior to 1992 (after which the external surface of the drywell shell was protected from further corrosion by a sand bed removal and the installation of a multi-layer epoxy coating system). As I demonstrate below, however, this corrosion rate is not possible with an epoxy-coated drywell shell. Moreover, even if this or a significantly higher corrosion rate was possible, AmerGen's committed frequency of UT measurements is more than adequate to detect such corrosion before the ASME Code-specified margins are exceeded.
- 13. Part of the reason why the corrosion rate was historically as high as 0.017" per year in certain bays of the drywell shell sand bed region is because there was a medium (i.e.,
sand) to physically hold water against the drywell shell. Specifically, the sand bed region got its name from the sand that was placed there as part of the original design.
Once water entered this area, the sand physically held the water against the shell, ensuring a constant source of water to facilitate corrosion of the metal drywell shell.
4
- 0. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 23 I D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 23I This sand, however, was removed as part of the corrective actions completed in 1992 to prevent additional corrosion in the sand bed region. So there is no water-retaining media to facilitate future corrosion.
- 14. Of course, such a corrosion rate of 0.017" per year is unrealistic because the drywell shell is protected from further corrosion by a multi-layer epoxy coating system.
AmerGen has demonstrated that corrosion of the external surface of the drywell shell has been arrested, and no additional Corrosion is possible umless there is a defect in the coating and water is able to come into contact with the metal drywell shell through that defect. Accordingly, it is my opinion that no corrosion is possible beneath an intact epoxy coating system, such as the one applied on the exterior of the OCNGS. This is because corrosion of a kind significant enough to affect the integrity of the drywell shell requires the presence of water and oxygen, and there is no water or oxygen adjacent to the metal surface of the drywell shell to initiate, let alone sustain, thie corrosion process.
- 15. Dr. Hausler, however, has speculated that there could be tiny defects in the coating, referred to as "pinholes" or "holidays." He essentially argues that water could get to the metal surface of the underlying drywell shell through these hypothetical, tiny defects. It is my opinion that even if there were such defects, they would not allow sufficient oxygenated water to reach the underlying drywell shell for corrosion to exceed ASME Code-specified margins before AmerGen would detect it through its committed inspections (i.e., every four years). Accordingly, this argument is simply not relevant to the long-term integrity of the drywell shell. The support for my opinion is presented in the next paragraphs.
5
I D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 24
- 16. We know that the maximum measured historical corrosion rate was not 0.017" per year, but was more than twice that at 0.039" per year (in location Bay 13A).1 So we know that with the presence of water, wetted sand holding that water adjacent to the uncoated shell, blocked drains preventing that water from being drained out of the sand bed region, and the temperature specific to the exterior of the drywell shell in the sand bed region during operations, that loss of metal at a rate of 0.039" per year is possible.
- 17. To show how absurd Citizens' argument is-that corrosion significant enough to affect the integrity of the drywell shell could occur through a pinhole or holiday in the epoxy coating-[ have made the following assumptions in my calculation, some of which are unrealistic and overly conservative:
" AmerGen performs the visual and UT inspections of the sand bed region in 2008 that it has already committed to; AmerGen does not perform inspections of the sand bed region in 2010, also consistent with its commitments (inspections are to be performed every four years after 2008);
The drywell shell is exposed to water during the 2010 scheduled refuieling outage. The source of the water is minor leakage from the refueling cavity, which only contains water during refueling outages, so the shell could not get wet prior to a refueling outage; Citizens' Petition states that a 'reasonable estimate of the worst case potential corrosion rate that may occur could be obtained by analyzing the pre-1992 data [i.e., before the sand was removed from the sand bed region].... Observed corrosion rates to 1990 ranged up to 0.035 inches per year and were very uncertain." While it is my understanding that AmerGen is not required to perform "worst case" analyses, the corrosion rates that occurred prior to removal of the sand from the sand bed region simply are not representative of the potential corrosion rates after removal of the sand. As I demonstrate in this Affidavit, even this order of magnitude corrosion does not challenge the integrity of the drywell shell.
6
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 25
- This water is not detected. This is conservative because AmerGen's commitments include monitoring the refueling cavity liner drain during outages, as well as the five sand bed region drains both quarterly and daily during outages;
- The water enters Dr. Hausler's hypothetical pinhole or holiday on the first day of the 2010 refueling outage. This is conservative because the refueling cavity is not even flooded on the first day of the outage;
" The pinhole or holiday is located within the region that has the least remaining margin (i.e., Bay 13). This is conservative because it is statistically unlikely that the thinnest area of the shell also has the defect in the coating;
" Corrosion at the maximum historical rate of 0.039" per year instantly begins as water enters the pinhole or holiday;
" Oxygen's contact with the metal surface is not mitigated by the presence of corrosion products. This is conservative because corrosion tends to be self-limiting when corrosion films are produced on the metal surface and corrosion byproducts (i.e., rust) create a diffusion barrier that reduces the amount of subsequent corrosion of the shell; The refueling outage takes four weeks to complete, and the cavity is filled with water during the entire refueling outage;
- The water stays in the pinhole during the entire four-week outage; and
- The water in the pinhole or holiday does not evaporate until a year after the refueling outage is over, and the 0.039" per year corrosion rate continues for the entire year after the outage, for a total of 56 weeks of new corrosion. This 7
D.AheI umr imsa uprigAfdvt~d ae2 D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 26 ervative because the temperature in the sand bed region of Put 1307F during operations, which would result in the e small amount of water in the pinhole or holiday in time. For example, at 130TF, a drying out rate of about 0.3 per square foot, is reasonable for a sand bed region with no d result in evaporation of water in the pinhole or holiday in There are many factors involved in the calculation of water One of the most important factors is the air or wind velocity across the water surface. I derived the 0.3 pounds per hour, per square foot value from the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) equation for evaporation from ponds or pools: W = [A + (B)(V)I(Pw - Pa)/Hv (where: W - water evaporation rate, (lb/hr) per sq.ft. of the water's surface area; A = a constant = 95; B = a constant = 37.4; V = air velocity over the pond surface, miles/hr (which I assumed was zero)' Pw = vapor pressure of water at the water temperature, inches of Hg; Pa = vapor pressure of water at the air dewpoint temperature, inches of Hg; and Hv = heat of vaporization of water at the pond water
0 D. Ashley - Summary Dismissal Supporting Affidavits.pdf P~oR 27 Page 27 I against the general average thickness criterion of 0.736"; and (b) the margin of 0.128" remaining in Bay 13A, when measured against the very local area average thickness of 0.490".
I declare under penalty of perjury that the foregoing affidavit and the matters stated therein are true and correct to the best of my knowledge, infnrnation, and belief.
Barry Cordon Structural Integrity Associates, Inc.
3315 Almaden Expressway, Suite 24 San Jose, CA 95118-1557 Subscribed and sworn before me this._._
day of March 2007.
- PAULA RODGERS Commtislon # 15404992 Noktry Pub4Ic
-Cawtornia Soant Clamr cw t
Notary Public y*ommisionE.xpires, i,
6 My Commission Expires:
-Jt*
9
I D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 281 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD Before Administrative Judges:
E. Roy Hawkens, Chair Dr. Paul B. Abramson Dr. Anthony J. Baratta In the Matter of:-
AmerGen Energy Company, LLC (License Renewal for Oyster Creek Nuclear Generating Station)
Docket No, 50-219 AFFIDAVIT OF JON R. CAVALLO City of Portsmouth State of New Hampshire Jon R. Cavallo, being duly sworn, states as follows:
INTRODUCTION I. This Affidavit is submitted to support ArnerGen Energy Company, LLC's Motion for Summary Disposition on the contention Filed by environmental and citizen groups
("Citizens") opposed to the renewal of the Oyster Creek Nuclear Generating Station operating license, and admitted by the Licensing Board on October 10, 2006.
Citizens' contention as admitted by the Licensing Board is: "AmerGen's scheduled
[ultrasonic testing ("UT")] monitoring frequency in the sand bed region is insufficient to maintain an adequate safety margin." The purpose of my Affidavit is provide
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page.29 ie multi-layer epoxy coating used on the exterior of the Oyster ie sand bed region, in order to address Citizens' contention.
hat Citizens' allegations have no technical merit because they standing of the nature of the epoxy coating, and of the n that coating.
DUCATION AND EXPERIENCE 1.
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 30 7
well as performed coating system failure analysis and attendant repair plans for operating nuclear generating facilities.
" After leaving Stone & Webster, I worked with Metalweld, Inc. until 1986 as its Northeastern United States regional manager. I was the project manager for all of the protective coatings work for the Seabrook Nuclear Plant.
From 1986 to 1991, 1 was a Senior Associate in the consulting engineering firm of S.G. Pinney & Associates, hic. During my employment with the firm, I performed protective coating and lining work at a number of nuclear generating facilities. I was the Professional Engineer assigned to all underwater protective lining work conducted by the firm.
)
From 1991 to 1998, 1 was an independent professional engineer performing corrosion engineering consulting services.
> From 1998 to the present, I have worked in my current capacity as Vice President of Corrosion Control Consultants & Labs, Inc.
- 6. 1 received my B.S. degree in Engineering Technology, curn laude, from Northeastern University in Boston, Massachusetts, in 1979. 1 have completed a variety of engineering and engineering management study programs, including U.S. Naval Nuclear Power Training, the University of Colorado (engineering project management), and NACE International (corrosion prevention in oil and gas production). I am a Registered Professional Engineer in six states, President of the Maine Society of Professional Engineers, and an SSPC-Society for Protective Coatings certified Protective Coating Specialist.
3
0.Ahe umr imsa uprigAfdvtrd Page.
1 I D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 31 l1
- 7. 1 am active on a number of national technical societies including SSPC, NACE and ASTM. I have served as Chairman of the Northern New England Chapter of SSPC from 1991 to 1998, Chairman of the New England Chapter of SSPC from 2000 to the present, and was a member of the SSPC National Strategic Planning Committee. I was elected Chairman of ASTM Committee D-33 (Protective Coating and Lining Work for Power Generation Facilities) for the period 2004 through 2008. 1 have also served as Chairman of the Industry Coating Phenomena Identification and Ranking Table (PIRT) Panel reviewing the work of Savannah River Technical Center on the USNRC Containment Coatings Research Project (Generic Safety Issue -191 ).
- 8. Based on my review of the relevant historical documentation, I am familiar with the historical corrosion of the OCNGS drywelt shell, and the actions taken to control corrosion.
- 9. 1 have also reviewed the relevant portions of the OCNGS License Renewal Application ("LRA") submitted to tile NRC on July 22, 2005, and the LRA supplement submitted to the NRC on December 3, 2006.
- 10. Finally, I testified before the Advisory Committee on Reactor Safeguards (ACRS) license renewal subcommittee on January 18, 2007, on the topic of the Oyster Creek drywell shell epoxy coating.
OPINIONS OF JON R. CAVALLO
- 11. Citizens have asserted that under corrosive conditions, long-term corrosion rates of more than 0.01 7 inches per year have been observed in the sand bed region of the Oyster Creek drywell shell. This assertion is based on public documents estimating 4.
-D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 32 long term corrosion rates in the period before the application of the epoxy coating to the drywell shell.
- 12. The historic corrosion occurred because, among other things, the drywell shell in the sand bed region was not coated. The exterior shell is now protected by a three-layer (pre-prime and two coats) epoxy coating system. This coating system was designed for submerged applications, such as tank bottoms, so even if water was always present in the sand bed region, it would have no effect on the coated steel shell. This coating was applied in the following manner:
)
Prior to application, Oyster Creek personnel created a mock-up of the sand bed region. Using the same mechanics, and with the same restricted access, personnel prepared the surface and applied to the coating to this mock-up. Through this process, Oyster Creek personnel qualified the surface preparation, coating application, and inspection techniques for use on the drywell shell.
> Following surface preparation of the drywell shell by SSPC-SP 2 hand tool cleaning that removed loose rust, loose mill scale, and loose coating, the pre-prime was applied.
- The pre-prime is a red epoxy coating that soaks and penetrates into the semi-irregular shape of the substrate metal.
Then two coats of the whitish-gray Devran-184 epoxy were applied with a brush and roller.
> Finally, a Devmat 124S caulking was used to seal the interface between the concrete floor and the steel substrate.
I D. Ashley - Summary Dismissal Supporting Affidavits.pdf pa'ge3.31 D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 33
- 13. Citizens speculate that there might be tiny holes in the epoxy coating - "pinholes" or "holidays" - which would allow water to get behind the coating, causing corrosion of the underlying drywell shell. Dr. Hausler has suggested that such holidays would be so small that they could not be detected with the naked eye during a visual inspection.
By definition, a pinhole or holiday is a very localized defect in the coating that occurs during the application and cure of the coating. Thus, these localized defects could only be caused by a defect in the original application of the coating, and cannot be caused by degradation over time.
- 14. As would be expected, the possibility of a pinhole or holiday decreases with each layer of coating that is applied. As I noted, the epoxy protecting the exterior of the drywell shell is comprised of a three layer (a pre-prime and two coats) coating system.
- 15. AmerGen's protective coating monitoring program includes VT-I visual inspections of the epoxy coating by qualified inspectors in accordance with NUREG-1801 and ASME Section 11, Subsection IWE. Under the VT-I method, trained and qualified individuals inspect surfaces such as the drywell shell for evidence of flaking, blistering, peeling, discoloration, and other signs of degradation. The VT-I technique is a proven method, used throughout the industry, on both boiling water reactors and pressurized water reactors. If a corrosion rate of 0.017" per year had occurred between 1992 and 2006, then it would have been readily detected by the VT-I inspections performed during the 2006 refueling outage. Future corrosion would also be detectable in a VT-I inspection.
6
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 34
- 16. This is because as carbon steel corrodes, the reaction between oxygen and the iron in the steel results in an iron oxide byproduct. The epoxy coating would not allow the corrosion byproducts to migrate from the site of the corrosion, so these byproducts would either accumulate as a blister at the corrosion site, or they would seep out through the postulated pinhole or holiday in the coating onto the otherwise whitish-gray epoxy coating. In either case, the corrosion byproducts would be clearly visible in a VT-I inspection.
- 17. It is well accepted cor~rosion science that corrosion byproduct occupies a volume seven to ten times greater than the underlying corroding steel. For example, if 0.017" of steel corrodes in a year under an epoxy coating, then between 0.119" and 0.170" of byproduct would result. Four years of corrosion at that rate--the interval that AmerGen will perform UT in the sand bed region-would result in between 0.476" and 0.680" of corrosion byproduct. Thus, the amount of corrosion that Citizens postulate would, in a four-year period, generate a blister under the epoxy coating of around '2-inch thickness. Such a blister would be clearly visible to an inspector qualified to perform VT-I inspections.
- 18. Therefore, a corrosion rate of 0.017" occurring in a pinhole since 1996 (the last time that strippable coating was not used during a refueling outage), would result in a 1.2" to 1.7" blister in the epoxy coating. Even if significant corrosion could occur behind a pinhole or holiday in the epoxy coating, corrosion at a rate of 0.017" per year would be visible through the VT-I inspections performed every four years.
- 19. In fact, Citizens' argument that such local defects have existed since 1992 is inconsistent with their argument that the air in the sand bed region is moist and 7
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 35 capable of corrosion. If a moist environment and pinholes coexisted for the past 14 years (1992 to 2006), then the resulting corrosion would be easily visible during the VT-1 inspections.
- 20. The VT-I inspections would also detect the corrosion products caused by much lower corrosion rates. Even a corrosion rate of 0.002 inches per year would yield corrosion products that would cause a blister of between 0.056" and 0.080" in the four year interval between inspections. Such a blister would also be visible in a VT-I inspection performed by a qualified inspector.
- 21. The VT-I Inspection is designed to be used on any type of steel or concrete surface, including textured concrete and irregular surfaces.such as welds. Therefore, the techniques used in this inspection would be adequate to use on surfaces such as the Oyster Creek drywell shell.
- 22. Also, the eight to ten year rated lifetime discussed in Citizens' Exhibit 6 to their original contention (this exhibit is a letter submitted to the NRC in 1995 by the previous owner of Oyster Creek Nuclear Generating Station) is simply incorrect. The multilayer epoxy coating is designed to withstand a submerged environment and to last for the life of the plant, including the extended period of operation, provided that proper VT-1 inspections are conducted and necessary corrective maintenance is performed to address any discrepancies found. This type of coating is commonly used throughout the nuclear industry, and there is no such limitation in life span.
8
D. Ashley - Summary Dismissal Supporting Affidavits.pdf Page 36 I declare under penalty of perjury that the foregoing affidavit and the matters stated therein are true and correct to the best of my knowledge, information, and belief.
J9 R. Cavallo 35 Heritage Avenue, Suite 2 Portsmouth, NH 03801 Subscribed and sworn before me this :____-'Jday of March, 2007.
ýqotary Public My Commission Expires:
JOVCE L. GOODWIN, Notary-Pubiic My OW=Wsloon Expres January 15 2W8 9
D. Ashley - 22 Fixity local thinning.pdf P.age 1 GE Nuclea.: £nerg
- ~O-
/7Y December 11, 1992 To:
Dr. Stephen Tumminelli Manager, Engineering Mechanics GPU Nuclear Corporation I Upper Pond Road Parsippany, NJ 07054
Subject:
Sandbed Local Thinning and Raising the Fixity Height Analyses (Line Items I and 2 in Contract # PC-0391407)
Dear Dr. Tumminelli:
The attached letter report documents the results of subject analyses. The original purchase order called for the analyses to be conducted on a spherical panel model rather than on the full pie slice model. However, the results are more useful when conducted on the full pie slice model since in that case no interpretation is required regarding the relationship between the sphcrical panel results and the pie slice model results. The pie slice model we have used in these studies has the refined mesh in the sandbed region.
A 3.5" PC Disk containing three ANSYS input files (0.636* case, 0.536" case and I foot wall case) is also enclosed with this letter. The detailed calculations have been filed in Chapter 10 of our Design Record File No. 00664.
This transmittal completes the scope of work identified in the subject PO. If you have any questions on the above item, please give me a call.
Sincerely, H.S. Mehta, Principal Engineer Materials Monitoring & Structural Analysis Services Mail Code 747; Phone (408) 925-5029
Attachment:
Letter Report cc:
D.K. Henrie (w/o Attach,)
J.M. Miller (w/o Attach.)
S. Ranganath (w/o Attach.)
HSMOC-57.wp
[ D. Ashley - 22 Fixity local thinning pdf
_Page,2 7/ y LETTER REPORT ON ADDITIONAL SANDBED REGION ANALYSES L0 SCOPE AND BACKGROUND Structural Analyses of the Oyster Creek drywell assuming a degraded thickness of 0.736 inch in the sandbed region (and sand removed) were documented in GENE Report Numbers 9-3 and 9-4. A separate purchase order was issued (Contract # PC-0391407) to perform additional analyses, The PO listed the additional analyses under two categories:
Line Item 001 and Line Item 002. This letter report documents the results of these analyses.
The additional analyses are the following:
(1)
Investigate the effect on the buckling behavior of drywell from postulated local thinning in the sandbed region beyond the uniform projected thickness of 0.736" used in the above mentioned reports (Line Item 001),
(2)
Determine the change in the drywell buckling margins when the fixity point at the bottom of the sandbed is moved upwards by -
I foot to simulate placement of concrete (Line Item 002).
The original PO called for the Line Item 001 analyses to be conducted on a spherical panel. The relative changes in the buckling load factors were to be assumed to be the same for the global pie slice model. However, the mesh refinement activity on the global pie slice model and the availability of work station, has given us the capability to conduct the same analyses on the global pie slice model itself, thus eliminating the uncertainties regarding the correlation between the panel model and the pie slice model.
All of the results reported in this report are based on the pie slice model with a refined mesh in the sandbed region.
2.0 LINE ITEM 001 Figure la shows the local thickness reductions modeled in the pie slice model. A locally thinned region of - 6"x12" is modeled. The thickness of this region is 0.636" in one
-I-
Page 3
[D. Ashley - 22 Fixity local thinning.pdf Page. 3 case and 0.536" in the other case. The transition to the sandbed projected thickness of 0.736" occurs over a distance of 12" (4 elements).
The various thicknesses indicated in Figure la were incorporated in the pie slice model by defining new real constants for the elements involved. The buckling analyses conducted as a result of mesh refinement indicated that the refueling loading condition is the governing case from the point of view of ASME Code margins. Therefore, the stress and buckling analyses were conducted using the refueling condition loadings. The center of the thinned area was located close to the calculated maximum displacement point in the refueling condition buckling analyses with uniform thickness of 0.736 inch. Figure lb shows the location of the thinned area in the pie slice model.
2.1 0.536 Inch Thickness Case Figures 2 through 5 show the membrane meridional and circumferential stress distributions from the refueling condition loads. As expected, the tensile circumferential stress (Sx in element coordinate system) and the compressive meridional stress (Sy in element coordinate system) magnitudes in the thinned region are larger than those at the other edge of the model where the thickness is 0.736 inch. However, this is a local effect and the average meridional stress and the average circumferential stress is not expected to change significantly.
Figures 6 and 7 show the first buckling mode with the symmetric boundary conditions at both the edges of the model (sym-sym).
This mode is clearly associated with the thinned region. The load factor value is 5.562. The second mode with the same boundary conditions is also associated with the thinned region. Figure 8 shows the buckled shape.
The load factor value is 5.872.
Next, buckling analyses were conducted with the symmetric boundary conditions specified at the thinned edge and the asymmetric boundary conditions at the other edge (sym-asym),
The load factor of the first mode for this case was 5.58. Figure 9 shows the buckling mode shape. It is clearly associated with the thinned region. Figure 10 shows the buckled mode shape with asymmetric boundary conditions at the both edges (asym-asym). As expected, the load factor for this case is considerably higher (7.037).
D. Ashley - 22 Fixity local thinning.pdf Page 4 I D. Ashley - 22 Fixity local thinning.pdf Page, i4 Thus, the load factor value of 5.562 is the lowest value obtained. The load factor for the same loading case (refueling condition) with a uniform thickness of 0.736" was 6.141.
Thus, the load factor is predicted to change from 6.141 to 5,562 with the postulated thinning to 0,536'.
2.2 0.636 Inch Thickness Case Figures II through 14 show the membrane meridional and circumferential stress distributions from the refueling condition loads. As expected, the tensile circumferential stress (Sx in element coordinate system) and the compressive meridional stress (Sy in element coordinate system) magnitudes in the thinned region are larger than those at the other edge of the model where the thickness is 0.736 inch. However, this is a local effect and the average meridional stress and the average circumferential stress is not expected to change significantly.
Figures 15 and 16 show the first buckling mode with the symmetric boundary conditions at both the edges of the model (sym-sym).
This mode is clearly associated with the thinned region. The load factor value is 5.91.
Next, buckling analysis was conducted with the symmetric boundary conditions specified at the thinned edge and the asymmetric boundary conditions at the other edge. The load factor of the first mode for this case was 5.945. Figure 17 shows the buckling mode shape. It is clearly associated with the thinned region. Based on the results of 0.536" case, the load factor for asym-asym case is expected to be considerably higher.
Thus, the load factor value of 5.91 is the lowest value obtained. The load factor for the same loading case (refueling condition) with a uniform thickness of 0.736" was 6,141.
Thus, the load factor is predicted to change from 6. 141 to 5.91 with. the postulated thinning to 0.636".
2.3 Summary The load factors for the postulated 0.536" and 0.636" thinning cases are 5.562 and 5.91, respectively. These values can be compared to 6.141 obtained for the case with a uniform sandbed thickness of 0.736 inch.
I D. Ashley - 22 Fixity local thinning.pdf Page 5I 3.0 LINE ITEM 002 The objective of this task was to determine the change in the drywell buckling margins when the fixity point at the bottom of the sandbed is moved upwards by -
I foot to simulate placement of concrete. The elements in the sandbed region are approximately 3-inch square. Thus the nodes associated with the bottom four row of elements (nodes 1027 through 1271, Figure 18) were fixed in all directions.
The buckling analyses conducted as a result of mesh refinement indicated that the refueling loading condition is the governing case from the point of view of ASME Code margins. Therefore, the stress and buckling analyses were conducted using the refueling condition loadings.
Figure 19 through 22 show the membrane meridional and circumferential stress distributions from the refueling condition loads. Figure 23 shows the calculated average values of meridional and circumferential stresses that are used in the buckling margin evaluation.
Figure 24 shows the first buckling mode with sym-sym boundary conditions. The load factor for this mode is 6.739. The load factor with asym-sym boundary conditions is 6.887 and the mode shape shown in Figure 25. It is clear that the sym-sym boundary condition gives the least load factor. Figure 26 shows the buckling margin calculation. It is seen that the buckling margin is 5.3% compared to 0% margin in the base case calculation.
To summarize, the load factor changes to 6.739 for the refueling condition when the fixity point at the bottom of the sandbed is moved upwards by -1 foot. This results in an excess margin of 5.3% above that required by the Code.
HSMOC-57. wp D. Ashley - 22 Fixity local thinning.pdf Page 6 MNuclear Calculation Sheet
? 2I-7 O,1~nAww Ro.sv'd by Dabo Th~ei L~ 4i?~U1/41-A e*d~
k
~
CAow Co.
0.73 CAM~ U) 7,
- J 1 '4 J
-I
~1 11 m
-l m
D. Ashley - 22 Fixity local thinning.pdf Page 7 I.
XV
-1 YV
=-D.8 DIST-718.786 XF
-303.031 ZF
-639.498 ANGZ--90 CENTROID HIDDEN
-3561
-2319
-1078 163.887 1406 2647 3889 5131 6372 7614
ANSYS 4.4A1 DEC 9 1992 17:43:35 POSTI STRESS STEP-I ITER=l SX (AVG)
MIDDLE ELEM CS DMX -0.222715 SMN -- 3561 SMX -7614
-xv
-1 zV
=-i ODIST-121.539 OXF
-46.39 70 OYF
-- 1.382 OZF =382.857 ANGZ--90 CENTROID HIDDEN
-3561
-2319
-1078 163.887 1406 2647 3889
[* 5131 s3J 6372 7614 OYSTFR CRFFK n ANAIYSIS -
OCRFTHI (NO SAND.
REFUELING)I I
-11 A'4 I C 4
AI N
DG OYSTER CREEK D~ ANALYSS CIH N
AD EULN ANSYS 4.4A1 DEC 9 1992 17:42:08 POST1 STRESS STEP-1 ITER=1 SY (AVG)
MIDDLE ELEM CS DMX -0.222715 SMN
-- 9943 SMX -701.049 XV
-l YV
-- 0.8 DIST-718.786 XF
-303.031 ZF
=639.498 ANGZ--90 CENTROID HIDDEN
-9943
-8760
-7577
-6395 5m
-212
-4030
-2847
-1664
-481.591 701.849
-V
olI T
ANSYS 4.4A1 DEC 9 1992 17:43:49 POSTI STRESS STEP-1 ITER=l SY (AVG)
MIDDLE ELEM CS DMX -0,222715 SMN -- 9943 SMX =701.049 XV
-1 ZV
--1
- DIST-121.539
- XF
-46.39 DYF
-- 1.382 OZF
-382.857 ANGZ--90 CENTROID HIDDEN
-9943
-8760
-7577
-6395
-5212
- 4030
-2847
-1664
-481.591 701.049 C
OYSTER CREEK DW A*ALYSIS OCRFTHI (NO SAND, REFUELING)
.ANSYS 4.4A1 K.. v.-:'..'
DEC 10 1992 S...POST1 STRESS
/STEP-1 Syfr~.'/,"I TER~l
- .u.g
",.,)..FACT-S
.552 ux D NODAL
)'y M
I D X -11.006073 SMN
-- 0.006072 SMX -0. 00345
-11xv
-1
- .,,*YV
--0.8 1DIST-89.401
,*F
-262. 142 rYF
-- 51. Il 42F
-148-214 0 ",
- :z A :
A NM Z -
! - U CENTROID HIDDEN
-0.006072
-0.005014
....].
-0.003956
-0.002898
-0.00184
-0 782E-03 SM0.276E-03 0.001334 o.002392 0.00345 OYSTER CREEK DRYWEL'L ANALYSIS OCRFUSBSS (NO SAND.
REFUELINGI OYSTER CREEK DRYWELL ANALYSIS - OCRFBSBSS (NO SAND REFUELING)
I
rAqbl-3.o/4 Ux D NODAL DMX -0.006414 SMN
-- 0.00641 SNX =0.002261 xv
-1 ZV
-- 1
- DIST-110.004
- XF
-29.455 OYF
-0.460954 SZF
-365.922 ANGZ--90 CENTROID HIDD
-0.00641
-0.00545
-0. 00448
-0.00352
--0. 0255
-0.00159
-0. 630E-0.333E-0 0.001297 0.002261 ANSYS 4.4A1 DEC 10 1992 8:10:04 POST1 STRESS STEP-i ITER=2 0
(0
-o ANSYS 4.4A1 DEC 10 1992 6:57:10 POSTI STRESS STEP-i ITER1I FACT-5.562 Ux O NODAL DMX -0.006073 SMN -- 0.006072 SNX -0.00345 XV
-1 xv-1 ZV
--I oDIST-1O.004
- XF -29.455 GYF -0.460954 OZF
-365.922 ANGZ--90 CENTROID HIDDEN
-0.006072
-0.005014
-0.003956
-0 002898
-0*00184
-0 782E-03 0.276E-03 E* 0.001334 0.002392 0.00345 ocRP5oaSs ANALYSIS -
Q (NO
- SAND, REFUELING)
ANSYS 4.4A1 J
I
- '..*DEC 10 1932
- t 8
- 10 :G4 I--
POSTI STRESS 7-......-
STEP-I
--- B'*(" "---"
?
ITER=2
- FACT-S
.,72
- X 0 NODAL y zDMX -0.006414
/*
/ '
£"*
"'K"....
/
SMN -- 0.006414
-t-/~I'-
I I
L zv
=-1
{
ODIST-110.004
-r-
- (iF
-29.455
- YF
-0.460954 S
- ZF
-365.922 ANGZ--90 CENTROID HIDDEN.
-0. 006414 o00.
-o.0o545 BFt
-Q0.0 448,6 r'
-0.003522
/
-0
- 002558,
- I
-0.001594 r-- 0.630E-03
- 0. 333E-03 0.001297 0.002261 OYSTER CEKDRY,/ELL ANALYSIS
-t!F (NO SAND, REFUELING)"
CREE0
ANSYS 4.4AI DEC 10 1992 10:12:22 POSTI STRESS STEP-i ITER-1 FACT-7.037 ux D NODAL DMX -0.003492 SMN -- 0.002088 S4X =0.002164 xV
-1 ZV
=-1
- DIST-110.004
- XF
-29.455 OYF
-0.460954
- ZF
-365.922 ANGZ--90 CENTROID HIDDE
-0.002088
-0.001615
-0.o001143
-0. 6-7O0E-0
-0.198E-0 0.274E-03 0.747E-03 0.001219 0.001691 0.002164 ANSYS 4.4A1 DEC 10 1992 7:29:08 POSTI STRESS STEP-1 ITER=i FACT-5.58 ux D NODAL DMX -0.005974 SMN -- 0.005972 SMX -0.003682 XV
-1 2v
=-1 o0IST-110.004
- XF
-29.455 oYF
-0.460954 QZF
-365.922 ANGZ--90 CENTROID HIDDEN
-0.005972
-0.0049
-0.003827
-0.002754
-0.001681
-0.609E-03 0.464E-03 0.001537 0.00261 0.003682 C..
N
-c CREEK 0'D AMALYSIS -
OCRFUSAS (NO
- SAND, REFUELING)
ANSYS 4.4A1 DEC 10 1992 10:12:22 POSTH STRESS STEP-i ITER-1 FACT-7.037 ux D NODAL DMX -0.003492 SNN -- 0.002088 SMX -0.002154 XV
-1 zv
=-1
-0DIST-11O.004 OXF
-29.455 OYF
=0.460954 T*
ZF
-365.922 rT]
ANGZ--90 CENTROID HIDDEN
-0.002088
-0.001615
-0.001143 S. -0.67 0E-03
-0.198E-03 0.274E-03 0.747E-03 0.001219 0.001691 0.002164 OYSTER CREEK OW AMALYSIS
-OCRFDSAA*
(NO
- SAND, REFUELING)
Yv
-- 0.8 DIST-718.786 XF
-303.031 ZF
=639.49a ANGZ--90 CENTROID HIDDEN
-3554
-2387
-1220
-52.809 1114 2281 3448 4615 5783 69501
-Z\\
I-
!j ANSYS 4.4A1 DEC 10 1992 8:21 :15 POSTI STRESS STEP-1 ITER=I SX (AVG)
MIDDLE ELEM CS DMX -0.222456 SMN -- 3554 SMX =6950 XV
-1 ZV
=-I
- DIST-121.539 I*XF
-46.39 UeYF
=-1.382
'ZF
-382.857
- t
- /
- ANGZ--90 CENTROID HIDDEN
-3554
-2387
-1220
-52.809
~1114 2281
~3448 4615 m
5783 6950 OYSTER CREEK DV ANALYSIS OCRFU.6S (NO
- SAND, REFUELING)
ANSYS 4.4A1 DEC 10 1992 8:l:45 POSTI STRESS STEP-I ITER-1 SY (AVG)
MIDDLE ELEM CS DMX -0.222456 SMN -- 8767 SMX =694.653 XV
-1 YV
=-0.8 DIST=718. 786 XF
-303.031 ZF
=639.498 ANG2=-91J
-CCENTROID HIDDEN
-8767
-7716 k
k
-6664 us*
-5613 v.L~ ~-4562
-2459
-356.637 694.6S3 OYSTER CREEK OW ANALYSIS -
OCRF06S (NO SAND, REFUELING)
C ci N,,
ANSYS
- 4. 4A1 C
DEC 10 1992"-
- r*--
1 8:1 30
- ' POSTI STRESS 0DSTE-12.3
- *SY (AVG)
MIDDLE E L EM C S DMX -0.222456
,SMN
-- 8767 S
SMX
-694. 653 "n '
i v =-1
-7716 vF I
-4562
- F
-1.382
- ZF
-356..857 OYSTER CREEK Did ABdALYSIS OCRFOSS (NO
- SAND, REFUELING}
i ANSYS 4.4AI DEC 10 1992 10 :36 :45
" A;':~
,pPOSTI STRESS STEP-1
"'0*{
ITER= 1 now"*(
FACT =5 9 D MODAL DNX -
0.0S 175 SMN -- 0.005174 SMX =0.00326 ixv
-1
,1
-0.
-o0.01
°DIST-89. 401 OXF
-262.142 O YF
=-Sl.lll P
- ZF
-148.214
.~ANG U-90
- j CENTROI D HIDDEN
~-0.005174
,*r~i
- -0.004237 I
-0.00233
-0.001425
-0. 488E-03
- 0. 001386
- 0. 002323 0.00326 "R4" tVT{O florrie nDwLIACI I A*£ AI VCTC nlP nCR<C -
n
-- Arfl OFI I 1 l
T"r.
1 9
1
.=:
- .p-,
L -
I I
XV
-1
- DIST-100.004
- F-29.455.
OYF
-0.4603254 r
=ZF
-365.922;,
~~ANGZ--g0 CENTROID HIDDEN 0.005174 II
- NOSN,
-U.LI4237 i
-o*oo2362
-0.001425 J~
f 0.488E-03 i
/
P0.449E-03
~0.
001386 0.002323 0.00326 (Ida SAND, REFUELING)
IN
AN5"YS 4.4AI DEC 10 1992 16:48:07 POST1 STRESS STEP=l ITER=l FACT=5.945 UX D NODAL DMX =0.005178 5MN =-0.005177 AM SMX =0.003584 XV
=1 "DIST=1I0.004
-XF
=29.455 C
-YF
=0.460954 ZF
=365.922 ANGZ=-90 CENTROID HIDDEN gm -0.005177 Ul
-0.0042o03
-0.00323
-0.002256
-0 001283
~-0.310E-03 0.664E-03 0.001637 0.002611 0.003584 OYSTER CREEK DW ANALYSIS - OCRF06AS (HO SAND, REFUELING)
ANSYS 4.4A1 DEC 7 1992 J!
12.44:31 POST1 STRESS I
STEP-1 ITER-I SX (AVG)
MIDDLE ELEM CS DMX
'0.211959 SMN -- 3547 SMX =6041 XV
-1 YV
-- 0.8 DIST-71a.786 XF
-303.031 ZF
-639.498 ANGZ=-90 CENTROID HIDDE
-3547 U
-24a2
-1416
-350.884 714. 437 1780 2845 4976 6041 Ni EFUELIUG)
ANSYS 4.4A1 DEC 7 1992 12:44:31 POST1 STRESS STEP-1 ITER-1 SX (AVG)
MIDDLE ELEM CS DMX -9.211959 SMN -- 3547 SMX =6041
-XV
-1 YV
-- 0.8 C
DIST-718.786 XF
-303.031 ZF
=633.49a ANGZ--90 CENTROID HIDDEN
-3547
-2482
-1416
-350. 884 714.437
'1780 2845 3910 4976 6041 NN OS.
OYSTER CREEK DRYV/ELL ANALYSIS OYCR1S (NO
- SAND, REFUELING})
.41
.i ANSYS 4.4A1 IaL DEC 7 19S2 12:3 3 33 POSTI STRESS t-N, STEP-I ITER=I Sx (AVG)
MIDDLE ELEM CS DMX -0.21159 SMN -- 3547 SMX =6041 XV
-1 ZV
=-i oDIST=121.539
- XF
-46.39
- YF
=-1. 382 ZF
-382.857 ANGZ--90 CENTROID HIDDEN S-3547 0i
-24a2 l -
1"-416
-350.8a4 714.437
_1780 2845 3910 i
4976 5041 OYSTER CREEK DRYWELL ANALYSIS OYCRlS (NO
- SAND, REFUELING)
.In c;
OYSTER CREEK DRYVELL AMALYSIS -OYCRIS (NO SAND, REFUELING)J ANSYS 4.4A1 DEC 7 1992 12:44:44 POST1 STRESS STEP-i ITER=I SY (AVG)
MIDDLE ELEM CS DMX -0.211959 SMN -- 7956 SNX -766.953 XV
-1 YV
-- 0.8 DIST-718.786 XF
-303.031 ZF
-639.498 ANGZ--90 CENTROID HIDDEN
-7956
-6987 n -6018
-5049
-4079
-2141
-1172
-202.301 766.953
'3
j.ANSYS 4.4A1 DEC 7 1992 12:34:18 q
POSTI STRESS STEP-1 ITER=I SY (AVG)
MIDDLE ELEM CS DMX -0.2119S9 SMN
-- 7956
-SMX 766. 953 zxv =-1
- J oIsT-1 1.539
- XF
-46.39 "YF
-- 1.382
- ZF
-382.8S7 ANGZ--90 CENTROID HIDDEN.
-7956
-6987
-6018
-j
-5049
-4079
-3110
-2141
-1172
-202.301 766.953 OYSTER CREEK ORYWELL ANALYSIS OYCRIS (MO SAND, REFUELING)
I D. Ashley - 22 Fixity local thinning.pdf Page 29 1 APPLIED MERIDIONAL AND CIRCUMFERENTIAL STRESSES REFUELING CONDITION ONE FOOT INCREASE ;N FIXITY CASE; STRESS RUN: OCRFRLSB.OJT AVERAGE APPLIED MERIDIONAL STRESS:
The average meridional stress is defined as the average stress across the elevation inctuding nodes 1W19 through 1467. Stresses at nodes 1419 and 1467 are aeithted only one nael as much as the other nodes Uecaouse they lie on the edge of the modeled 1/10th section of the dryweil and thus represent only '42 of t-e area represented by the other nodes.
N of Nodes
- of Meridfonat Meridional Nodes Nodes Stress (ksi)
Stress (ksi) 1419-14,67 1423-1463 1427-1459 1431 -*(55 1435-1451 1439-1447 1443 Total 1
2 2
2 12
-7.726
-7.738
-7.760
-7.682
.7.394
-7,014
-6.834
-7.726
-15.476
-15.520
-15.364
-14. 78
- 14.028
-6.834
-89.736 12 Average Meridional Stress:
AVERAGE APPLIED CIRCUMFERENTIAL STRESS:
The circýroferential stress is averaged along node 1223 to node 2058.
-7.4n8 (kvi)
Nodes 1 223 1419 1615 1811 2058
- of Nodes 0
Circuinferentiat Stress (ksi)
-1.175 0.505 4.165 5.846 5.024 the vertical line from N of Nodes Clrcuwferentiat Stress (ksi) 0.000 0.505 4.165 5.846 5.024 15.54 4
3.885 (ksi)
Average Circumferential Stress:
OCRFS106.WKI
ANSY5 4.4AI DEC 8 1992
-Aw 6: 15: 38 POSTI STRESS STEP=I ITER=I W
FACT=6.739 D NODAL DMX =0.003681 SMN =-0.00368 SMX =0.001848 zv=-
C
~
- DIST=110.004
-XF =29.455
~T1
-YF
=0.460954
- ZF
=365.922 ANGZ=-90 CENTROID HIDDEN
-0.00368
-0.003065
-0.002451
-0.001837
-0.001223
___-0.609E-03 0.567E-05 0.620E-03 0.001234 0.001848 OYSTER CREEK ORYWELL ANALYSIS ocrfs-s 0NO SAND.
REFUELING)
REFUELING CASE, NO SAND
- UN OCRFRLSB.OUT, LOAD UNITS VALUE FACTOR (in.)
(in.)
(ksi)
(ksi) 420 0.736 38 29600 2
E Stress, Ste
- tress, Sm Stress, Sc
.ULATION it Pressure, Peq
^2
- or, ALPHA i,mod
.ss, Se kLCULATION L = NUi x Se
'ALCULATION ill = Si/FS Ill/Sm -1) x 100%
(ksi) 50.394 6.739 (ksi) 7.478 (ksi) 3.885 ANSYS 4.4AI DEC 9 1992 11:35:17 POST1 STRESS STEP-1 ITER=I FACT-6.88?
UX D MODAL DMX =0.005136 SMN -- 0.005134 SMX =0.003244 XV
-1 zv
-- l ODIST=IlO.004
- XF
-29.455 OYF
-0.460954 OZF
=365.922 AIMGZ= -90 CENTROID HIDDEM
- 0.005134
-0.004Z03
-0.003273
--0.002342
-0.001411
- 0.
8OE-03 0.4S1E-03 a.001382 0.002313 0.003244 (psi)
(ksi) 0.207 13.616 0.075 0.064 0.313 15.753 0.415 1.000 (ksi) 15.753 (ksi) 7.877 f%)
5.3 2.107 2.107 1.053
CALCULATION OF AILOWABLE BUCKLING STRESSES -
REFUELING CASE, NO SAND ONE FOOT INCREASE IN FIXITY CASE; STRESS RUN OCRFRLSB.OUT, BUCKLING RUN OYCRSBBK.OUT ITEM PARAMETER 1
2 3
4 5
DRYWELL GEOMETRY AND MATERIALS Sphere Radius, R
Sphere Thickness, t Material Yield Strength, Sy Material Modulus of Elasticity, E Factor of Safety, FS UNITS (in.)
(in.)
(ks i)
(ksi)
LOAD VALUE FACTOR 420 0.736 38 29600 2
11" C
ri BUCKLING ANALYSIS RESULTS 6
Theoretical Elastic Instability Stress, Ste STRESS ANALYSIS RESULTS 7
Applied Meridional Compressive Stress, Sm 8
Applied Circumferential Tensile Stress, Sc (ksi) 50.394 6.739 (ksi) 7.478 (ksi) 3.885 t,.)
9 10 11 12 13 14 15 16 17 CAPACITY REDUCTION FACTOR CALCULATION Capacity Reduction Factor, ALPHAi Circumferential Stress Equivalent Pressure, Peq
'X' Parameter, X= (Peq/4E) (d/t)^2 Delta C (From Figure
)
Modified Capacity Reduction Factor, ALPHA,i,mod Reduced Elastic Instability Stress, Se
- PLASTICITY REDUCTION FACTOR CALCULATION Yield Stress Ratio, DELTA=Se/Sy Plasticity Reduction Factor, NUi Inelastic Instability Stress, Si = NUi x Se (psi)
(ksi) 0.207 13.616 0.075 0.064 0.313 15.753
- 2. 107 0.415 1.000 (ksi) 15.753 (ksi) 7.877
(%)
5.3 2.107 1..053
- ALLOWABLE COMPRESSIVE STRESS CALCULATION 18 Allowable Compressive Stress, Sall=
Si/FS 19 Compressive Stress Margin, M=(Sall/Sm -1) x 100%
-¶1 REFNSND2.WK1