ML071090247

From kanterella
Jump to navigation Jump to search

Generator Tube Integrity Assessment from the 2006 Refueling Outage
ML071090247
Person / Time
Site: Palisades Entergy icon.png
Issue date: 04/11/2007
From: Schwarz C
Entergy Nuclear Operations
To:
Document Control Desk, NRC/NRR/ADRO
References
Download: ML071090247 (57)


Text

-Entergy Entergy Nuclear Operations, Inc.

Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 April 11,2007 Technical Specification 5.6.8 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Palisades Nuclear Power Plant Docket 50-255 License No. DPR-20 Steam Generator Tube Integrity Assessment from the 2006 Refueling Outage Entergy Nuclear Operations, Inc. (ENO) is providing the Palisades Nuclear Plant (PNP)

Steam Generator Tube Integrity Assessment Report for the 2006 refueling outage. The inservice inspection was completed on April 19, 2006. At the time of the inspection, PNP Technical Specification (TS) 5.6.8.b required that this report be submitted to the Nuclear Regulatory Commission within 12 months following the completion of the inservice inspection. Subsequent to this inspection, TS 5.6.8 was revised with implementation of Amendment 223. ENO is required to submit future Steam Generator Tube Integrity Assessment Reports within 180 days after the initial entry into mode 4.

Summary of Commitments This letter contains no new commitments and no revisions to existing commitments.

Christopher J2 "

arz" Site Vice President Palisades Nuclear Plant Enclosure (1)

CC Administrator, Region Ill, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC A /Da

ENCLOSURE 1 STEAM GENERATOR TUBE INTEGRITY ASSESSMENT 2006 REFUELING OUTAGE 55 Pages Follow

PALISADES NUCLEAR PLANT STEAM GENERATOR TUBE SURVEILLANCE REPORT 2006 REFUELING OUTAGE Assisment Sponsor 3 -

2-Z00 7 Date 2IA4'4R~O7' Eddy Current Level III Review Date Supervisor Review Date Marfa' ger Review Date

TABLE OF CONTENTS TITLE PAGE TABLE OF CONTENTS 1.0 PURPOSE 1.1 TECHNICAL SPECIFICATIONS TABLE 1 NUMBER AND EXTENT OF TUBES INSPECTED TABLE 2 IDENTIFICATION OF TUBES PLUGGED TABLE 3 SUPPORT STRUCTURE NOMENCLATURE TABLE 4 ACRONYMS AND THREE LETTER NDE CODES 1

2 3

3 3

4 5

5 ATTACHMENT 1 ATTACHMENT 2 STEAM GENERATOR E-50A INDICATIONS STEAM GENERATOR E-50B INDICATIONS 6

34 2

1.0 PURPOSE 1.1 TECHNICAL SPECIFICATIONS It is the intent of this Steam Generator Tube Surveillance Report to provide all the information required to meet the reporting requirements of Palisades Technical Specification 5.6.8b. The specific information is identified below:

Number (as a percentage) and extent of tubes inspected is located in Table 1.

" Identification of tubes plugged is located in Table 2.

Location and percent wall-thickness penetration for each indication of an imperfection is located in Attachment 1 for Steam Generator E-50A Indications and Attachment 2 for Steam Generator E-50B Indications.

Steam generator support structure nomenclature can be found Acronyms and three letter NDE codes be found in Table 4.

in Table 3.

Table 1 Number and Extent of Tubes Inspected Scope Probe Type SG E-50A SG E-50B Full LengthO Bobbin 100%

100%

Row 1 through 3 U-bends MRPC 100%

100%

Row 4 U-bends MRPC N/A 100%

Hot Leg Tubesheets TTS+3"/-1 3.5" MRPC 100%

100%

Cold Leg Periphery TTS+2"/-2" MRPC 11.3%

11.4%

Dings and Dents > 5.0 Volts MRPC 100%

100%

Eggcrate Dents > 2.0 but < 5.0 Volts MRPC 100%

100%

Historical Wear at Eggcrates MRPC 100%

100%

Historical Wear at Diagonal Bars MRPC 25%

25%

and Vertical Straps SupplementalO MRPC 100%

100%

Plug Visual N/A 100%

100%

(D)Except the bend portion ot rows 1 through 3 0 All DNI, DSI, NQI, PLP (Bound MRPC PLP's), PVN and new wear indications.

3

Table 2 Identification of Tubes Plugged SG Row Column Location Reason For Plugging E-50A 5

12 TSH Restricted Tube (RST) Foreign Object E-50A 93 32 VS6 + 16.81" Single Axial Indication (SAI)(10.5 Volt DNG)

E-50A 34 47 TSH + 0.02" Single Axial Indication (SAI)

E-50A 26 53 TSH + 0.43" Single Axial Indication (SAI)

E-50A 90 67 TSH + 0.25" Single Volumetric Indication (SVI)(PLP)

E-50A 134 67 VS7 + 0.78" 40% Throughwall Wear (WAR)

E-50A 137 72 VS6 - 0.86" 43% Throughwall Wear (WAR)

E-50A 70 75 TSH + 0.61" Single Axial Indication (SAI)

E-50A 133 76 VS2- 0.92" 40% Throughwall Wear (WAR)

E-50A 77 78 TSH + 0.01" Single Circumferential Indication (SCI)

E-50A 138 79 DBH + 1.99" 40% Throughwall Wear (WAR)

E-50A 72 81 TSH - 0.04" Single Circumferential Indication (SCI)

E-50A 71 84 01 H - 0.22" Single Axial Indication (SAI)

E-50A 72 87 TSH - 0.01" Single Circumferential Indication (SCI)

E-50A 133 90 04H + 7.52" Single Axial Indication (SAI)(NQI)

E-50A 73 96 TSH + 0.69" Single Axial Indication (SAI)

TSH + 0.22" E-50A 56 105 TSH + 0.23" Two Single Axial Indications (2 SAI's)

TSH - 0.44" E-50A 24 109 TSH - 0.97" Two Single Axial Indications (2 SAI's)

E-50A 126 113 VS1 - 0.63" 42% Throughwall Wear (WAR)

E-50A 27 118 TSH - 0.01" Single Circumferential Indication (SCI)

E-50A 57 128 TSH + 0.11" Single Circumferential Indication (SCI)

O5H + 18.61" E-50A 80 131 to 06H + 11.3" Seven Single Axial Indications (7 SAI's)

E-50B 26 3

TSC + 0.39" Single Volumetric Indication (SVI)(PLP)

E-50B 29 48 TSH + 0.63" Single Axial Indication (SAI)

E-50B 128 75 TSH + 0.78" Possible Loose Part (TBP)

TSH + 0.10" E-50B 130 75 to TSH + 0.92" Three Possible Loose Parts (TBP)

TSH + 0.33" E-50B 129 76 TSH + 0.60" Two Possible Loose Parts (TBP)

TSH + 0.06" E-50B 131 76 TSH + 0.41" Two Single Volumetric Indications (SVI)(PLP)

E-50B 79 90 TSH + 0.41" Single Axial Indication (SAl)

E-50B 74 95 TSH + 0.84" Single Axial Indication (SAI)

E-50B 3

130 05C/05H Administrative (TBP)

E-50B 45 136 VS4 + 0.91" 40% Throughwall Wear (WAR) 4

Table 3 Support Structure Nomenclature Name Description Name Description TEH Tube End - Hot Side VS4 Fourth Vertical Strap TSH Top of Tubesheet - Hot Side VS5 Fifth Vertical Strap 01H First Eggcrate - Hot Side VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side VS7 Seventh Vertical Strap 03H Third Eggcrate - Hot Side DBC Diagonal Strap - Cold Side 4H Fourth Eggcrate - Hot Side 08C Eighth Eggcrate - Cold Side 05H Fifth Eggcrate - Hot Side 07C Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side 06C Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side 05C Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side 4C Fourth Eggcrate - Cold Side DBH Diagonal Strap - Hot Side 03C Third Eggcrate - Cold Side VS1 First Vertical Strap 02C Second Eggcrate - Cold Side VS2 Second Vertical Strap 01C First Eggcrate - Cold Side VS3 Third Vertical Strap TSC Top of Tubesheet - Cold Side I

TEC Tube End - Cold Side Table 4 Acronyms and Three Letter NDE Codes Acronym Definition MRPC Motorized Rotating Pancake Coil (+Pt.TM)

NDE Non Destructive Examination NTE No Tube Expansion SAI Single Axial Indication SVI Single Volumetric Indication TBP To Be Plugged TTS Top of Tubesheet

<TS Less Than Technical Specification WAR Wear Indication 5

Steam Generator E-50A Indications NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 1

E-50A C

9 2

19 02C 0.12 0

<TS 2

E-50A C

13 2

9 02H

-1.01 0

<TS 3

E-50A C

13 2

19 02H 0.93 0

<TS 4

E-50A C

14 3

24 02C 0.79 0

<TS 5

E-50A C

26 3

20 02C

-1 0

<TS 6

E-50A C

26 5

8 02H

-1.02 0

<TS 7

E-50A C

26 5

16 02H

-0.17 0

<TS 8

E-50A C

28 5

16 DBC 1.48 0

<TS 9

E-50A C

40 5

16 01C

-0.86 0

<TS 10 E-50A C

42 5

15 02H 0.9 0

<TS 11 E-50A C

41 6

14 02C

-0.26 0

<TS 12 E-50A C

32 7

20 02C

-0.92 0

<TS 13 E-50A C

42 7

11 02C 0.06 0

<TS 14 E-50A C

42 7

21 02C 0.9 0

<TS 15 E-50A C

48 7

24 01C 0.86 0

<TS 16 E-50A C

47 8

16 01H

-0.85 0

<TS 17 E-50A C

55 8

15 01C

-0.03 0

<TS 18 E-50A C

28 9

25 05C

-1.2 0

<TS 19 E-50A C

49 10 20 VS4 0.92 0

<TS 20 E-50A C

53 10 16 01C

-0.95 0

<TS 21 E-50A C

62 11 16 01C

-0.84 0

<TS 22 E-50A C

64 11 13 06H 0.73 0

<TS 23 E-50A C

64 11 25 VS4

-0.86 0

<TS 24 E-50A C

64 11 16 VS5 1.14 0

<TS 25 E-50A C

63 12 16 01C

-0.92 0

<TS 26 E-50A C

65 12 22 06H 0.6 0

<TS 27 E-50A C

67 12 15 03H 0.86 0

<TS 28 E-50A C

64 13 17 04H 0.96 0

<TS 29 E-50A C

64 13 19 VS4

-0.95 0

<TS 30 E-50A C

67 14 25 05H 0.84 0

<TS 31 E-50A C

73 14 14 05H

-0.93 0

<TS 32 E-50A C

34 15 14 VS4

-0.96 0

<TS 33 E-50A C

74 15 22 VS4 0.79 0

<TS 34 E-50A C

74 15 14 01C

-0.91 0

<TS 35 E-50A C

76 15 31 DBC

-1.52 0

<TS 36 E-50A C

31 16 25 VS4 0.84 0

<TS 37 E-50A C

51 16 17 VS4

-0.54 0

<TS 38 E-50A C

75 16 28 VS5

-0.85 0

<TS 39 E-50A C

75 16 22 06C 0.09 0

<TS 40 E-50A C

77 16 29 VS4

-0.93 0

<TS 41 E-50A C

79 16 15 DBH

-1.24 0

<TS 42 E-50A C

38 17 20 05H

-0.11 0

<TS 43 E-50A C

51 18 7

VS4 0.47 0

<TS 6

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 44 E-50A C

51 18 7

DBC 1.98 0

<TS 45 E-50A C

79 18 14 VS4

-0.59 0

<TS 46 E-50A C

4 19 16 DBH 0.45 0

<TS 47 E-50A C

28 19 21 VS4

-0.8 0

<TS 48 E-50A C

44 19 11 VS4 0.58 0

<TS 49 E-50A C

48 19 34 VS4

-0.43 0

<TS 50 E-50A C

48 19 26 VS4 0.62 0

<TS 51 E-50A C

76 19 10 DBC 1.69 0

<TS 52 E-50A C

84 19 18 VS2 0.66 0

<TS 53 E-50A C

84 19 23 VS4

-0.92 0

<TS 54 E-50A C

84 19 22 VS4 0.65 0

<TS 55 E-50A C

84 19 18 VS5 0.84 0

<TS 56 E-50A C

41 20 15 05H 0.85 0

<TS 57 E-50A C

49 20 26 VS4

-0.73 0

<TS 58 E-50A C

49 20 24 VS4 0.82 0

<TS 59 E-50A C

51 20 31 VS3

-0.68 0

<TS 60 E-50A C

85 20 23 VS4

-0.84 0

<TS 61 E-50A C

85 20 21 VS4 0.65 0

<TS 62 E-50A C

87 20 18 VS4

-0.12 0

<TS 63 E-50A C

87 20 22 VS4 0.66 0

<TS 64 E-50A C

44 21 26 VS4

-0.77 0

<TS 65 E-50A C

44 21 20 VS4

-0.06 0

<TS 66 E-50A C

44 21 26 VS4 0.68 0

<TS 67 E-50A C

48 21 24 VS4

-0.75 0

<TS 68 E-50A C

68 21 22 VS4

-0.82 0

<TS 69 E-50A C

68 21 22 VS4 0.92 0

<TS 70 E-50A C

68 21 15 VS5

-0.06 0

<TS 71 E-50A C

68 21 19 VS5 0.9 0

<TS 72 E-50A C

88 21 23 VS4

-0.84 0

<TS 73 E-50A C

39 22 21 01H 0.82 0

<TS 74 E-50A C

69 22 25 VS4

-1.04 0

<TS 75 E-50A C

69 22 16 VS4

-0.03 0

<TS 76 E-50A C

69 22 27 VS4 0.88 0

<TS 77 E-50A C

69 22 24 VS5 0.88 0

<TS 78 E-50A C

81 22 13 DBC

-1.52 0

<TS 79 E-50A C

87 22 16 VS4

-0.83 0

<TS 80 E-50A C

91 22 31 VS4 0.65 0

<TS 81 E-50A C

90 23 13 VS4

-0.81 0

<TS 82 E-50A C

92 23 18 VS2 0.56 0

<TS 83 E-50A C

92 23 17 VS2 1.01 0

<TS 84 E-50A C

92 23 24 VS6 0.98 0

<TS 85 E-50A C

47 24 13 04H

-0.68 0

<TS 86 E-50A C

49 24 14 VS4

-0.8 0

<TS 87 E-50A C

67 24 25 06H 0.8 0

<TS 88 E-50A C

95 24 26 VS4

-0.72 0

<TS 89 E-50A C

95 24 18 VS4 0.32 0

<TS 7

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 90 E-50A C

14 25 17 05H

-1.1 0

<TS 91 E-50A C

18 25 14 VS4

-1.19 0

<TS 92 E-50A C

88 25 13 VS4

-0.68 0

<TS 93 E-50A C

94 25 17 VS4

-0.93 0

<TS 94 E-50A C

96 25 20 02H 0.84 0

<TS 95 E-50A C

96 25 35 VS4 0.88 0

<TS 96 E-50A C

85 26 17 03H 0.82 0

<TS 97 E-50A C

99 26 27 VS4

-0.7 0

<TS 98 E-50A C

56 27 13 03H

-0.76 0

<TS 99 E-50A C

66 27 14 06C 0.8 0

<TS 100 E-50A C

80 27 16 VS3 0.98 0

<TS 101 E-50A C

98 27 19 VS2 0.58 0

<TS 102 E-50A C

98 27 11 VS6

-0.73 0

<TS 103 E-50A C

98 27 18 VS6 0.87 0

<TS 104 E-50A C

100 27 25 VS4

-0.84 0

<TS 105 E-50A C

100 27 17 VS4 0.96 0

<TS 106 E-50A C

49 28 15 03C 0.9 0

<TS 107 E-50A C

48 29 17 03C 0.93 0

<TS 108 E-50A C

50 29 14 04C 0.9 0

<TS 109 E-50A C

54 29 18 02C 0.9 0

<TS 110 E-50A C

60 29 19 04H 0.96 0

<TS 111 E-50A C

84 29 20 VS2 0.82 0

<TS 112 E-50A C

100 29 17 04H 0.9 0

<TS 113 E-50A C

100 29 21 05H 0.86 0

<TS 114 E-50A C

100 29 21 06H 0.88 0

<TS 115 E-50A C

100 29 16 VS2

-0.74 0

<TS 116 E-50A C

100 29 22 VS2 0.93 0

<TS 117 E-50A C

100 29 20 VS4 0.82 0

<TS 118 E-50A C

102 29 23 VS4

-1.11 0

<TS 119 E-50A C

37 30 15 05H 0.83 0

<TS 120 E-50A C

45 30 16 04H

-0.84 0

<TS 121 E-50A C

45 30 12 04H

-0.15 0

<TS 122 E-50A C

51 30 13 06H

-0.82 0

<TS 123 E-50A C

59 30 17 03C 0.84 0

<TS 124 E-50A C

67 30 16 06C

-0.99 0

<TS 125 E-50A C

95 30 36 VS4

-0.68 0

<TS 126 E-50A C

95 30 31 VS4 0.88 0

<TS 127 E-50A C

101 30 20 04H

-0.11 0

<TS 128 E-50A C

101 30 17 VS4

-0.72 0

<TS 129 E-50A C

103 30 17 VS4 0.77 0

<TS 130 E-50A C

105 30 27 VS4

-0.52 0

<TS 131 E-50A C

28 31 20 VS4

-0.9 0

<TS 132 E-50A C

52 31 16 03C 0.81 0

<TS 133 E-50A C

66 31 20 04H 0.92 0

<TS 134 E-50A C

94 31 22 VS4

-1.03 0

<TS 135 E-50A C

104 31 19 VS4

-0.84 0

<TS 8

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 136 E-50A C

104 31 20 VS4 1

0

<TS 137 E-50A C

106 31 31 VS6

-0.77 0

<TS 138 E-50A C

106 31 29 VS6 0.97 0

<TS 139 E-50A C

106 31 23 04C 0.92 0

<TS 140 E-50A C

9 32 16 DBC 0.98 0

<TS 141 E-50A C

103 32 19 VS4

-0.92 0

<TS 142 E-50A C

105 32 18 0iC 0.15 0

<TS 143 E-50A C

107 32 32 VS4

-0.79 0

<TS 144 E-50A C

42 33 9

DBH

-1.64 0

<TS 145 E-50A C

42 33 15 DBC

-1.62 0

<TS 146 E-50A C

52 33 13 06H 0.82 0

<TS 147 E-50A C

60 33 16 DBC 1.88 0

<TS 148 E-50A C

62 33 17 03H 0.9 0

<TS 149 E-50A C

84 33 20 VS2

-0.79 0

<TS 150 E-50A C

106 33 19 VS4

-0.74 0

<TS 151 E-50A C

108 33 30 VS4

-0.79 0

<TS 152 E-50A C

108 33 27 VS4 0.9 0

<TS 153 E-50A C

13 34 20 03C

-0.92 0

<TS 154 E-50A C

37 34 22 DBC 1.65 0

<TS 155 E-50A C

41 34 15 03H

-0.78 0

<TS 156 E-50A C

47 34 14 03C 0.75 0

<TS 157 E-50A C

109 34 15 01H 0.98 0

<TS 158 E-50A C

109 34 31 VS4 0.6 0

<TS 159 E-50A C

38 35 23 03H 0.92 0

<TS 160 E-50A C

38 35 26 04H 0.92 0

<TS 161 E-50A C

38 35 14 05H 0.08 0

<TS 162 E-50A C

38 35 17 05H 0.78 0

<TS 163 E-50A C

40 35 15 02C 0.2 0

<TS 164 E-50A C

62 35 17 03H 0.85 0

<TS 165 E-50A C

66 35 16 03H 1

0

<TS 166 E-50A C

66 35 18 04H 0.91 0

<TS 167 E-50A C

106 35 21 03C 0.85 0

<TS 168 E-50A C

108 35 28 0iC 0.12 0

<TS 169 E-50A C

108 35 19 0iC 0.91 0

<TS 170 E-50A C

110 35 18 01H 1.01 0

<TS 171 E-50A C

37 36 8

04H

-0.96 0

<TS 172 E-50A C

37 36 14 04H

-0.22 0

<TS 173 E-50A C

113 36 19 VS4

-0.62 0

<TS 174 E-50A C

32 37 9

03H 0.03 0

<TS 175 E-50A C

32 37 15 03H 0.93 0

<TS 176 E-50A C

64 37 15 VS3 0.21 0

<TS 177 E-50A C

64 37 17 VS5 0.97 0

<TS 178 E-50A C

84 37 17 VS2

-0.84 0

<TS 179 E-50A C

96 37 15 VS6

-0.99 0

<TS 180 E-50A C

112 37 10 DBH

-2.3 0

<TS 181 E-50A C

112 37 21 02C

-1.05 0

<TS 9

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 182 E-50A C

114 37 31 DBH 1.28 0

<TS 183 E-50A C

114 37 39 VS2

-0.81 0

<TS 184 E-50A C

114 37 13 VS2 0.88 0

<TS 185 E-50A C

114 37 15 VS6 0.94 0

<TS 186 E-50A C

114 37 6

08C

-1.13 0

<TS 187 E-50A C

114 37 20 08C 1.03 0

<TS 188 E-50A C

37 38 19 03C 0.75 0

<TS 189 E-50A C

59 38 16 03H 0.86 0

<TS 190 E-50A C

67 38 14 06H 0.95 0

<TS 191 E-50A C

115 38 13 VS4 0.67 0

<TS 192 E-50A C

115 38 17 02C

-0.89 0

<TS 193 E-50A C

115 38 17 02C 0.06 0

<TS 194 E-50A C

50 39 14 04H 0.89 0

<TS 195 E-50A C

84 39 12 VS2

-0.8 0

<TS 196 E-50A C

84 39 20 VS3

-0.83 0

<TS 197 E-50A C

110 39 19 VS2 0.88 0

<TS 198 E-50A C

116 39 17 VS6

-0.56 0

<TS 199 E-50A C

116 39 30 02C

-0.84 0

<TS 200 E-50A C

23 40 16 VS4 1.02 0

<TS 201 E-50A C

55 40 9

DBC 1.49 0

<TS 202 E-50A C

69 40 16 04H 0.9 0

<TS 203 E-50A C

87 40 19 07H

-0.63 0

<TS 204 E-50A C

87 40 11 07H 0.03 0

<TS 205 E-50A C

87 40 18 07C 0.79 0

<TS 206 E-50A C

117 40 24 VS4

-0.93 0

<TS 207 E-50A C

117 40 13 02C

-0.17 0

<TS 208 E-50A C

117 40 24 02C 0.81 0

<TS 209 E-50A C

24 41 15 VS4

-0.87 0

<TS 210 E-50A C

42 41 30 VS4

-0.81 0

<TS 211 E-50A C

42 41 25 VS4 0.47 0

<TS 212 E-50A C

44 41 21 VS4

-0.03 0

<TS 213 E-50A C

48 41 35 VS4

-0.87 0

<TS 214 E-50A C

48 41 19 VS4 0.87 0

<TS 215 E-50A C

56 41 14 02H

-0.11 0

<TS 216 E-50A C

68 41 14 04H 0.93 0

<TS 217 E-50A C

96 41 14 VS6

-0.47 0

<TS 218 E-50A C

96 41 18 VS6 1.16 0

<TS 219 E-50A C

100 41 15 06C 0.7 0

<TS 220 E-50A C

108 41 17 VS4 0.86 0

<TS 221 E-50A C

112 41 18 VS4

-0.96 0

<TS 222 E-50A C

118 41 20 VS4

-0.87 0

<TS 223 E-50A C

118 41 27 02C

-0.03 0

<TS 224 E-50A C

39 42 18 03C

-0.86 0

<TS 225 E-50A C

59 42 12 VS3 0.84 0

<TS 226 E-50A C

113 42 16 VS4

-0.88 0

<TS 227 E-50A C

113 42 11 VS4 0.98 0

<TS 10

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 228 E-50A C

117 42 35 0iC

-1 0

<TS 229 E-50A C

42 43 21 04H 0.9 0

<TS 230 E-50A C

48 43 36 VS4

-0.75 0

<TS 231 E-50A C

48 43 10 VS4 0.24 0

<TS 232 E-50A C

48 43 23 VS4 0.75 0

<TS 233 E-50A C

118 43 34 0iC

-0.96 0

<TS 234 E-50A C

41 44 13 05C

-0.95 0

<TS 235 E-50A C

41 44 16 03C

-0.96 0

<TS 236 E-50A C

43 44 15 04C 0.95 0

<TS 237 E-50A C

73 44 16 04H 0.9 0

<TS 238 E-50A C

73 44 20 06C

-0.87 0

<TS 239 E-50A C

75 44 33 VS3

-0.96 0

<TS 240 E-50A C

75 44 20 VS3 0.84 0

<TS 241 E-50A C

77 44 17 VS3 1.06 0

<TS 242 E-50A C

77 44 18 VS4

-0.1 0

<TS 243 E-50A C

77 44 23 VS5 0.88 0

<TS 244 E-50A C

107 44 15 05H

-0.98 0

<TS 245 E-50A C

107 44 18 05H

-0.14 0

<TS 246 E-50A C

107 44 15 VS2 0.78 0

<TS 247 E-50A C

107 44 12 VS4 0.91 0

<TS 248 E-50A C

111 44 19 06C

-0.2 0

<TS 249 E-50A C

121 44 16 VS4 0.15 0

<TS 250 E-50A C

121 44 17 0iC

-1.02 0

<TS 251 E-50A C

68 45 15 06H 0.8 0

<TS 252 E-50A C

106 45 14 05H

-0.14 0

<TS 253 E-50A C

33 46 16 02H 0.86 0

<TS 254 E-50A C

43 46 24 VS4

-1.08 0

<TS 255 E-50A C

55 46 13 04H

-0.98 0

<TS 256 E-50A C

81 46 25 VS5 0.94 0

<TS 257 E-50A C

97 46 18 VS6

-0.7 0

<TS 258 E-50A C

97 46 16 VS6

-0.11 0

<TS 259 E-50A C

115 46 14 VS4

-0.8 0

<TS 260 E-50A C

38 47 16 02H 0.89 0

<TS 261 E-50A C

48 47 28 VS4

-0.84 0

<TS 262 E-50A C

48 47 37 VS4 1.05 0

<TS 263 E-50A C

106 47 15 04C

-0.06 0

<TS 264 E-50A C

106 47 15 04C 0.72 0

<TS 265 E-50A C

118 47 16 02H 0.89 0

<TS 266 E-50A C

79 48 15 04C

-0.17 0

<TS 267 E-50A C

91 48 19 07C 0.14 0

<TS 268 E-50A C

91 48 16 05C

-0.94 0

<TS 269 E-50A C

95 48 21 06C 0.97 0

<TS 270 E-50A C

97 48 16 VS4

-0.88 0

<TS 271 E-50A C

97 48 16 VS4 0.96 0

<TS 272 E-50A C

97 48 18 VS6

-0.78 0

<TS 273 E-50A C

97 48 17 VS6 0.89 0

<TS 11

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 274 E-50A C

97 48 10 DBC 1.74 0

<TS 275 E-50A C

123 48 16 05C 0.91 0

<TS 276 E-50A C

125 48 22 VS4

-0.63 0

<TS 277 E-50A C

18 49 13 VS4

-0.81 0

<TS 278 E-50A C

44 49 18 04H 0.96 0

<TS 279 E-50A C

44 49 28 VS4

-0.49 0

<TS 280 E-50A C

44 49 25 VS4 0.15 0

<TS 281 E-50A C

44 49 21 05C

-1.02 0

<TS 282 E-50A C

62 49 16 05H 0.89 0

<TS 283 E-50A C

124 49 15 01H 0.9 0

<TS 284 E-50A C

37 50 11 04H

-0.79 0

<TS 285 E-50A C

37 50 16 04H 0.96 0

<TS 286 E-50A C

47 50 16 VS4 0.93 0

<TS 287 E-50A C

59 50 15 06H 0.83 0

<TS 288 E-50A C

75 50 24 VS3

-1.01 0

<TS 289 E-50A C

75 50 17 VS3 0.9 0

<TS 290 E-50A C

97 50 29 VS2

-0.79 0

<TS 291 E-50A C

97 50 18 VS2 0.87 0

<TS 292 E-50A C

97 50 22 VS4

-0.8 0

<TS 293 E-50A C

97 50 21 VS4 0.93 0

<TS 294 E-50A C

97 50 22 VS6 0.84 0

<TS 295 E-50A C

115 50 16 VS4

-0.83 0

<TS 296 E-50A C

121 50 15 06C 0.86 0

<TS 297 E-50A C

38 51 30 04C 0.98 0

<TS 298 E-50A C

46 51 18 03H 0.86 0

<TS 299 E-50A C

50 51 14 03H 0.91 0

<TS 300 E-50A C

76 51 16 VS4 0.9 0

<TS 301 E-50A C

94 51 17 04C 0.85 0

<TS 302 E-50A C

98 51 16 05C 0.96 0

<TS 303 E-50A C

116 51 21 07H 0.97 0

<TS 304 E-50A C

126 51 24 03H 0.91 0

<TS 305 E-50A C

41 52 25 VS4

-0.68 0

<TS 306 E-50A C

45 52 15 03H 0.93 0

<TS 307 E-50A C

63 52 15 06C 0.79 0

<TS 308 E-50A C

97 52 10 VS2

-0.81 0

<TS 309 E-50A C

97 52 23 VS2 0.81 0

<TS 310 E-50A C

97 52 30 VS4

-0.83 0

<TS 311 E-50A C

97 52 28 VS6 0.73 0

<TS 312 E-50A C

107 52 16 02H 0.99 0

<TS 313 E-50A C

119 52 25 06C 0.84 0

<TS 314 E-50A C

127 52 13 03C

-0.11 0

<TS 315 E-50A C

28 53 18 02H 0.93 0

<TS 316 E-50A C

28 53 21 VS4

-0.9 0

<TS 317 E-50A C

28 53 11 DBC

-1.77 0

<TS 318 E-50A C

46 53 28 VS4

-0.87 0

<TS 319 E-50A C

46 53 23 VS4 1

0

<TS 12

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 320 E-50A C

68 53 14 04H

-0.11 0

<TS 321 E-50A C

70 53 23 03C 0.17 0

<TS 322 E-50A C

84 53 24 VS2

-0.84 0

<TS 323 E-50A C

88 53 20 VS4 0.9 0

<TS 324 E-50A C

88 53 23 07C 0.78 0

<TS 325 E-50A C

116 53 15 05C 0.92 0

<TS 326 E-50A C

122 53-16 06H 0.88 0

<TS 327 E-50A C

128 53 21 02H

-0.88 0

<TS 328 E-50A C

41 54 16 04C

-1.01 0

<TS 329 E-50A C

69 54 19 03C

-0.95 0

<TS 330 E-50A C

71 54 15 04H 0.97 0

<TS 331 E-50A C

71 54 14 03C 0.77 0

<TS 332 E-50A C

81 54 17 05C

-1.06 0

<TS 333 E-50A C

97 54 15 05C

-0.12 0

<TS 334 E-50A C

97 54 16 05C 0.87 0

<TS 335 E-50A C

129 54 26 02C

-0.92 0

<TS 336 E-50A C

46 55 19 VS4 0.93 0

<TS 337 E-50A C

70 55 23 03C

-0.69 0

<TS 338 E-50A C

72 55 19 03C

-0.89 0

<TS 339 E-50A C

76 55 23 03C 0.75 0

<TS 340 E-50A C

98 55 15 05H 0.92 0

<TS 341 E-50A C

98 55 14 DBC

-1.79 0

<TS 342 E-50A C

37 56 22 04H 0.95 0

<TS 343 E-50A C

53 56 17 03H 0.83 0

<TS 344 E-50A C

65 56 16 06C 0.79 0

<TS 345 E-50A C

69 56 16 03C 0.75 0

<TS 346 E-50A C

73 56 15 05C

-0.88 0

<TS 347 E-50A C

87 56 17 04C 0.8 0

<TS 348 E-50A C

127 56 16 VS1

-0.77 0

<TS 349 E-50A C

129 56 21 02H 1.01 0

<TS 350 E-50A C

88 57 21 07C 0.81 0

<TS 351 E-50A C

130 57 24 08H 0.82 0

<TS 352 E-50A C

87 58 13 VS2

-0.58 0

<TS 353 E-50A C

93 58 26 VS2

-0.85 0

<TS 354 E-50A C

93 58 22 VS2 0.93 0

<TS 355 E-50A C

93 58 21 VS4 0.8 0

<TS 356 E-50A C

93 58 28 VS6 0.93 0

<TS 357 E-50A C

97 58 19 07C 0.92 0

<TS 358 E-50A C

117 58 16 06C 0.9 0

<TS 359 E-50A C

129 58 30 02H 0.88 0

<TS 360 E-50A C

129 58 16 07H

-1 0

<TS 361 E-50A C

40 59 18 05H 0.95 0

<TS 362 E-50A C

42 59 19 04H 0.99 0

<TS 363 E-50A C

64 59 15 05C 0.84 0

<TS 364 E-50A C

66 59 18 06C 0.84 0

<TS 365 E-50A C

88 59 15 05C 0.21 0

<TS 13

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 366 E-50A C

88 59 18 05C 0.93 0

<TS 367 E-50A C

92 59 14 VS4

-0.73 0

<TS 368 E-50A C

92 59 15 VS4 0.95 0

<TS 369 E-50A C

92 59 14 VS6 0.69 0

<TS 370 E-50A C

96 59 18 04C

-0.84 0

<TS 371 E-50A C

106 59 24 VS4

-1.16 0

<TS 372 E-50A C

106 59 34 VS4 1.03 0

<TS 373 E-50A C

106 59 22 VS6

-0.81 0

<TS 374 E-50A C

112 59 26 VS4

-0.4 0

<TS 375 E-50A C

112 59 31 VS6 0.95 0

<TS 376 E-50A C

41 60 25 05H 0.84 0

<TS 377 E-50A C

87 60 19 VS2

-0.83 0

<TS 378 E-50A C

93 60 15 VS2

-0.74 0

<TS 379 E-50A C

93 60 22 VS2 0.83 0

<TS 380 E-50A C

93 60 17 VS6

-0.96 0

<TS 381 E-50A C

93 60 14 VS6 1.07 0

<TS 382 E-50A C

119 60 16 VS4

-0.91 0

<TS 383 E-50A C

133 60 13 02H

-0.87 0

<TS 384 E-50A C

133 60 13 02H 0.93 0

<TS 385 E-50A C

133 60 13 VS4 0.57 0

<TS 386 E-50A C

66 61 16 04H 0.79 0

<TS 387 E-50A C

82 61 18 VS3

-0.87 0

<TS 388 E-50A C

84 61 14 03C 0.09 0

<TS 389 E-50A C

84 61 30 03C 0.83 0

<TS 390 E-50A C

88 61 24 03C 0.54 0

<TS 391 E-50A C

88 61 24 02C 0.86 0

<TS 392 E-50A C

96 61 16 06H 0.92 0

<TS 393 E-50A C

96 61 19 06C 0

0

<TS 394 E-50A C

126 61 11 08C

-0.92 0

<TS 395 E-50A C

132 61 14 01H 0.22 0

<TS 396 E-50A C

37 62 22 04H 1.04 0

<TS 397 E-50A C

39 62 13 05H 0.17 0

<TS 398 E-50A C

97 62 20 06C 0.78 0

<TS 399 E-50A C

97 62 17 05C

-0.9 0

<TS 400 E-50A C

111 62 22 VS2

-0.89 0

<TS 401 E-50A C

133 62 16 03H 0.76 0

<TS 402 E-50A C

28 63 18 VS4

-0.87 0

<TS 403 E-50A C

34 63 15 DBC 1.27 0

<TS 404 E-50A C

56 63 19 VS5 0

0

<TS 405 E-50A C

86 63 14 06C 0.69 0

<TS 406 E-50A C

96 63 22 04C 0.93 0

<TS 407 E-50A C

104 63 15 07C

-0.84 0

<TS 408 E-50A C

106 63 13 VS4

-1.2 0

<TS 409 E-50A C

106 63 15 VS4 0.19 0

<TS 410 E-50A C

108 63 17 VS2 0.8 0

<TS 411 E-50A C

116 63 14 VS6

-0.4 0

<TS 14

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 412 E-50A C

118 63 19 VS4

-0.88 0

<TS 413 E-50A C

118 63 15 VS4 0.95 0

<TS 414 E-50A C

19 64 20 DBH

-1.5 0

<TS 415 E-50A C

19 64 21 DBC

-1.54 0

<TS 416 E-50A C

21 64 12 DBH

-1.39 0

<TS 417 E-50A C

97 64 20 06C

-0.95 0

<TS 418 E-50A C

133 64 17 05H

-0.08 0

<TS 419 E-50A C

133 64 13 VS1 0.96 0

<TS 420 E-50A C

44 65 23 VS4

-0.65 0

<TS 421 E-50A C

46 65 17 VS4 0.77 0

<TS 422 E-50A C

56 65 18 VS4 1

0

<TS 423 E-50A C

96 65 15 05H

-0.85 0

<TS 424 E-50A C

98 65 22 VS2

-0.74 0

<TS 425 E-50A C

102 65 30 05H

-0.75 0

<TS 426 E-50A C

134 65 23 07H

-0.11 0

<TS 427 E-50A C

134 65 16 08H 0.88 0

<TS 428 E-50A C

134 65 14 DBH

-1.97 0

<TS 429 E-50A C

49 66 19 VS4 0.03 0

<TS 430 E-50A C

49 66 19 VS4 0.81 0

<TS 431 E-50A C

91 66 17 05C 0.9 0

<TS 432 E-50A C

133 66 16 VS4

-0.58 0

<TS 433 E-50A C

94 67 19 VS6

-0.95 0

<TS 434 E-50A C

94 67 12 VS6 0.95 0

<TS 435 E-50A C

100 67 30 VS6

-0.95 0

<TS 436 E-50A C

102 67 13 07C 0.15 0

<TS 437 E-50A C

106 67 21 VS6 0.47 0

<TS 438 E-50A C

132 67 19 VS2

-0.87 0

<TS 439 E-50A C

134 67 24 VS4

-0.91 0

<TS 440 E-50A C

134 67 23 VS4 0.06 0

<TS 441 E-50A C

134 67 12 VS4 0.9 0

<TS 442 E-50A C

134 67 39 VS7

-0.84 0

<TS 443 E-50A C

75 68 19 02C 0.85 0

<TS 444 E-50A C

113 68 15 VS6 0.97 0

<TS 445 E-50A C

46 69 14 VS4

-0.25 0

<TS 446 E-50A C

48 69 32 VS4 0.81 0

<TS 447 E-50A C

70 69 15 05H

-0.11 0

<TS 448 E-50A C

92 69 17 05C 0.18 0

<TS 449 E-50A C

92 69 15 05C 0.8 0

<TS 450 E-50A C

106 69 15 VS4

-1.2 0

<TS 451 E-50A C

106 69 15 VS6 0.81 0

<TS 452 E-50A C

126 69 14 08H

-1.04 0

<TS 453 E-50A C

126 69 15 VS4

-0.93 0

<TS 454 E-50A C

126 69 35 VS4 0.89 0

<TS 455 E-50A C

128 69 18 08H 0.91 0

<TS 456 E-50A C

134 69 20 VS7 0.15 0

<TS 457 E-50A C

134 69 28 VS7 0.69 0

<TS 15

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 458 E-50A C

136 69 17 VS7

-0.98 0

<TS 459 E-50A C

136 69 13 DBC

-1.85 0

<TS 460 E-50A C

136 69 14 DBC 1.2 0

<TS 461 E-50A C

49 70 18 VS4 0.86 0

<TS 462 E-50A C

89 70 19 06C 0.96 0

<TS 463 E-50A C

89 70 14 05C

-0.8 0

<TS 464 E-50A C

91 70 15 VS6 0.98 0

<TS 465 E-50A C

97 70 15 07H 0.75 0

<TS 466 E-50A C

99 70 14 06H

-0.21 0

<TS 467 E-50A C

101 70 16 05H 0.88 0

<TS 468 E-50A C

131 70 13 DBC 1.7 0

<TS 469 E-50A C

82 71 15 VS3 1.01 0

<TS 470 E-50A C

94 71 14 05C

-0.83 0

<TS 471 E-50A C

104 71 15 DBH 1.99 0

<TS 472 E-50A C

128 71 20 VS1

-0.9 0

<TS 473 E-50A C

128 71 31 VS1 0.94 0

<TS 474 E-50A C

128 71 17 VS2 0.09 0

<TS 475 E-50A C

130 71 20 VS4

-0.96 0

<TS 476 E-50A C

134 71 16 VS1 0.22 0

<TS 477 E-50A C

134 71 20 VS1 0.89 0

<TS 478 E-50A C

79 72 17 VS3 0.09 0

<TS 479 E-50A C

127 72 20 VS6

-0.36 0

<TS 480 E-50A C

135 72 28 VS1

-1.03 0

<TS 481 E-50A C

135 72 16 VS1 0.91 0

<TS 482 E-50A C

135 72 15 VS7 0.36 0

<TS 483 E-50A C

137 72 17 VS2 0.68 0

<TS 484 E-50A C

137 72 26 DBC 1.29 0

<TS 485 E-50A C

84 73 17 05C 0.84 0

<TS 486 E-50A C

88 73 19 02H

-0.2 0

<TS 487 E-50A C

130 73 14 VS6 0.86 0

<TS 488 E-50A C

130 73 21 VS7 0.68 0

<TS 489 E-50A C

134 73 16 VS6 1.1 0

<TS 490 E-50A C

49 74 20 VS4

-0.8 0

<TS 491 E-50A C

83 74 15 05H 0.81 0

<TS 492 E-50A C

129 74 17 VS1

-0.99 0

<TS 493 E-50A C

133 74 19 VS4 0.15 0

<TS 494 E-50A C

133 74 24 VS4 0.75 0

<TS 495 E-50A C

135 74 18 VS4

-0.52 0

<TS 496 E-50A C

137 74 9

VS1

-0.41 0

<TS 497 E-50A C

137 74 18 VS1 0.28 0

<TS 498 E-50A C

137 74 17 VS1 0.87 0

<TS 499 E-50A C

78 75 12 02H 0.19 0

<TS 500 E-50A C

98 75 22 06C 0.96 0

<TS 501 E-50A C

102 75 16 VS2

-0.5 0

<TS 502 E-50A C

114 75 12 06H 0.87 0

<TS 503 E-50A C

136 75 11 06C 0.81 0

<TS 16

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 504 E-50A C

138 75 10 07H

-1.04 0

<TS 505 E-50A C

138 75 13 07H 0.78 0

<TS 506 E-50A C

138 75 24 DBH 1.7 0

<TS 507 E-50A C

138 75 9

08C

-0.99 0

<TS 508 E-50A C

138 75 15 08C 0.15 0

<TS 509 E-50A C

138 75 13 07C 0.9 0

<TS 510 E-50A C

65 76 12 02H

-0.08 0

<TS 511 E-50A C

83 76 17 02H 0.95 0

<TS 512 E-50A C

93 76 19 VS4 0.03 0

<TS 513 E-50A C

113 76 18 VS6 0.86 0

<TS 514 E-50A C

127 76 17 VS1

-0.91 0

<TS 515 E-50A C

133 76 18 VS1

-0.95 0

<TS 516 E-50A C

133 76 28 VS1 0.86 0

<TS 517 E-50A C

133 76 18 VS4 0.2 0

<TS 518 E-50A C

133 76 25 VS4 0.69 0

<TS 519 E-50A C

133 76 15 VS6

-0.68 0

<TS 520 E-50A C

133 76 28 VS6 0.98 0

<TS 521 E-50A C

135 76 18 DBC 1.88 0

<TS 522 E-50A C

137 76 28 VS4

-0.81 0

<TS 523 E-50A C

137 76 23 VS4

-0.26 0

<TS 524 E-50A C

80 77 20 04H 0.99 0

<TS 525 E-50A C

94 77 16 VS2

-0.46 0

<TS 526 E-50A C

94 77 27 VS2 0.79 0

<TS 527 E-50A C

120 77 10 07C 0.17 0

<TS 528 E-50A C

126 77 16 VS1 0.92 0

<TS 529 E-50A C

128 77 18 07C 0.97 0

<TS 530 E-50A C

136 77 25 DBC 1.86 0

<TS 531 E-50A C

71 78 12 VS4

-0.64 0

<TS 532 E-50A C

71 78 10 VS4 0.89 0

<TS 533 E-50A C

71 78 17 06C

-1.01 0

<TS 534 E-50A C

89 78 11 07H

-0.88 0

<TS 535 E-50A C

89 78 19 07H 0.88 0

<TS 536 E-50A C

115 78 21 06H

-0.72 0

<TS 537 E-50A C

135 78 15 VS1 0.95 0

<TS 538 E-50A C

135 78 33 VS6 0.83 0

<TS 539 E-50A C

135 78 21 08C

-1.02 0

<TS 540 E-50A C

135 78 10 08C 0.84 0

<TS 541 E-50A C

137 78 19 VS4

-0.67 0

<TS 542 E-50A C

137 78 20 VS4 1.03 0

<TS 543 E-50A C

137 78 14 VS7 0.78 0

<TS 544 E-50A C

82 79 16 07C 0.71 0

<TS 545 E-50A C

110 79 18 06C

-0.22 0

<TS 546 E-50A C

136 79 13 08C

-0.99 0

<TS 547 E-50A C

136 79 10 07C

-0.82 0

<TS 548 E-50A C

136 79 29 07C

-0.11 0

<TS 549 E-50A C

138 79 11 08H 0.03 0

<TS 17

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 550 E-50A C

138 79 14 08H 0.87 0

<TS 551 E-50A C

138 79 15 VS1

-0.86 0

<TS 552 E-50A C

138 79 18 VS1 0.95 0

<TS 553 E-50A C

138 79 16 VS6

-0.9 0

<TS 554 E-50A C

53 80 10 03H

-0.94 0

<TS 555 E-50A C

53 80 13 03H 0.97 0

<TS 556 E-50A C

55 80 13 02H 0.94 0

<TS 557 E-50A C

91 80 16 05C 0.96 0

<TS 558 E-50A C

127 80 15 VS7 0.63 0

<TS 559 E-50A C

127 80 18 06C 0.91 0

<TS 560 E-50A C

137 80 19 VS6

-0.97 0

<TS 561 E-50A C

137 80 17 VS7 0.23 0

<TS 562 E-50A C

137 80 26 VS7 0.82 0

<TS 563 E-50A C

68 81 7

03H

-0.85 0

<TS 564 E-50A C

68 81 17 03H 1.07 0

<TS 565 E-50A C

70 81 17 DBC 1.55 0

<TS 566 E-50A C

116 81 15 VS6

-0.85 0

<TS 567 E-50A C

120 81 20 07C 0.17 0

<TS 568 E-50A C

120 81 19 07C 0.96 0

<TS 569 E-50A C

120 81 16 06C 1.03 0

<TS 570 E-50A C

122 81 22 VS4 1.12 0

<TS 571 E-50A C

138 81 28 DBH 1.88 0

<TS 572 E-50A C

138 81 13 VS1

-0.93 0

<TS 573 E-50A C

138 81 8

VS1 0.99 0

<TS 574 E-50A C

138 81 21 VS4 0.94 0

<TS 575 E-50A C

138 81 36 VS6

-0.95 0

<TS 576 E-50A C

138 81 28 VS6 0.84 0

<TS 577 E-50A C

138 81 18 VS7 0.06 0

<TS 578 E-50A C

138 81 19 VS7 0.75 0

<TS 579 E-50A C

138 81 18 08C

-0.93 0

<TS 580 E-50A C

63 82 21 03H 1.05 0

<TS 581 E-50A C

63 82 11 06H 1.12 0

<TS 582 E-50A C

75 82 14 03H 1.09 0

<TS 583 E-50A C

79 82 18 03H 1.04 0

<TS 584 E-50A C

87 82 18 05H 0.9 0

<TS 585 E-50A C

103 82 12 05H

-0.77 0

<TS 586 E-50A C

103 82 19 05H

-0.16 0

<TS 587 E-50A C

103 82 10 06H 0.08 0

<TS 588 E-50A C

103 82 17 06H 0.88 0

<TS 589 E-50A C

117 82 14 05H

-0.89 0

<TS 590 E-50A C

121 82 17 VS4

-0.46 0

<TS 591 E-50A C

135 82 18 08H 0.84 0

<TS 592 E-50A C

54 83 21 03H 0.99 0

<TS 593 E-50A C

54 83 13 04H

-0.11 0

<TS 594 E-50A C

64 83 11 03H 1.1 0

<TS 595 E-50A C

66 83 13 06C 0.9 0

<TS 18

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 596 E-50A C

88 83 15 04H

-0.7 0

<TS 597 E-50A C

88 83 15 05H

-0.71 0

<TS 598 E-50A C

92 83 14 05C 0.72 0

<TS 599 E-50A C

126 83 15 07H 0.06 0

<TS 600 E-50A C

138 83 15 08H

-1.12 0

<TS 601 E-50A C

138 83 9

08H

-0.16 0

<TS 602 E-50A C

138 83 23 DBH 2.24 0

<TS 603 E-50A C

138 83 14 VS1

-0.42 0

<TS 604 E-50A C

63 84 11 DBH

-1.68 0

<TS 605 E-50A C

81 84 29 VS4 0.98 0

<TS 606 E-50A C

81 84 21 07C

-0.27 0

<TS 607 E-50A C

133 84 18 08H

-0.03 0

<TS 608 E-50A C

58 85 16 03H 1.06 0

<TS 609 E-50A C

70 85 16 03H 0.94 0

<TS 610 E-50A C

72 85 13 05C 0

0

<TS 611 E-50A C

84 85 12 04H

-0.99 0

<TS 612 E-50A C

84 85 18 04H 0.89 0

<TS 613 E-50A C

92 85 16 VS6 1.07 0

<TS 614 E-50A C

98 85 16 06C 0.7 0

<TS 615 E-50A C

128 85 17 DBH 1.89 0

<TS 616 E-50A C

136 85 17 08H

-1.07 0

<TS 617 E-50A C

138 85 16 08H

-1.07 0

<TS 618 E-50A C

138 85 21 VS7 0.87 0

<TS 619 E-50A C

138 85 16 DBC

-1.66 0

<TS 620 E-50A C

138 85 15 08C

-0.11 0

<TS 621 E-50A C

138 85 11 08C 0.68 0

<TS 622 E-50A C

63 86 16 03C

-1.08 0

<TS 623 E-50A C

63 86 14 02C

-0.97 0

<TS 624 E-50A C

69 86 17 06C 0.86 0

<TS 625 E-50A C

91 86 14 05H 0.11 0

<TS 626 E-50A C

103 86 16 VS2 0.22 0

<TS 627 E-50A C

103 86 18 VS2 0.69 0

<TS 628 E-50A C

135 86 18 VS4 0.92 0

<TS 629 E-50A C

135 86 18 DBC

-1.18 0

<TS 630 E-50A C

96 87 15 05H 0.91 0

<TS 631 E-50A C

96 87 19 05C 1.07 0

<TS 632 E-50A C

98 87 12 06C

-0.87 0

<TS 633 E-50A C

98 87 24 06C 0.87 0

<TS 634 E-50A C

104 87 24 04C

-0.75 0

<TS 635 E-50A C

138 87 15 08C 0.84 0

<TS 636 E-50A C

53 88 14 03C

-0.91 0

<TS 637 E-50A C

55 88 15 02C

-0.91 0

<TS 638 E-50A C

83 88 7

04C

-0.39 0

<TS 639 E-50A C

83 88 19 04C 0.82 0

<TS 640 E-50A C

137 88 16 VS4

-0.75 0

<TS 641 E-50A C

137 88 14 VS6

-0.69 0

<TS 19

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 642 E-50A C

137 88 18 VS6

-0.12 0

<TS 643 E-50A C

92 89 20 04C 0.65 0

<TS 644 E-50A C

102 89 19 04C 0.65 0

<TS 645 E-50A C

112 89 16 VS4

-0.86 0

<TS 646 E-50A C

116 89 21 VS1 0.94 0

<TS 647 E-50A C

116 89 31 VS4

-1.2 0

<TS 648 E-50A C

116 89 35 VS4

-0.91 0

<TS 649 E-50A C

116 89 35 VS6 0.97 0

<TS 650 E-50A C

130 89 13 DBC

-1.72 0

<TS 651 E-50A C

134 89 13 DBC

-1.98 0

<TS 652 E-50A C

51 90 15 04C

-0.14 0

<TS 653 E-50A C

59 90 13 02C

-0.99 0

<TS 654 E-50A C

65 90 14 02C 0.89 0

<TS 655 E-50A C

79 90 11 04C

-1.01 0

<TS 656 E-50A C

79 90 19 04C

-0.21 0

<TS 657 E-50A C

91 90 22 03C 0.67 0

<TS 658 E-50A C

97 90 24 VS6

-0.62 0

<TS 659 E-50A C

105 90 19 05C 0.96 0

<TS 660 E-50A C

115 90 16 VS2

-1.02 0

<TS 661 E-50A C

115 90 39 VS4

-0.74 0

<TS 662 E-50A C

135 90 20 08C 0.82 0

<TS 663 E-50A C

76 91 16 02C 0.7 0

<TS 664 E-50A C

132 91 20 DBC

-1.71 0

<TS 665 E-50A C

134 91 20 VS6

-0.45 0

<TS 666 E-50A C

134 91 26 VS7

-0.9 0

<TS 667 E-50A C

134 91 30 DBC 1.96 0

<TS 668 E-50A C

136 91 20 08C

-0.89 0

<TS 669 E-50A C

136 91 26 08C 0.92 0

<TS 670 E-50A C

136 91 20 07C

-0.84 0

<TS 671 E-50A C

136 91 20 06C

-1.06 0

<TS 672 E-50A C

51 92 6

02C

-0.38 0

<TS 673 E-50A C

51 92 16 02C 0.94 0

<TS 674 E-50A C

53 92 19 03C 0.93 0

<TS 675 E-50A C

77 92 16 02C

-1.02 0

<TS 676 E-50A C

87 92 20 04C 0.68 0

<TS 677 E-50A C

115 92 27 VS1 0.75 0

<TS 678 E-50A C

133 92 24 VS6 0.89 0

<TS 679 E-50A C

137 92 33 VS6

-0.77 0

<TS 680 E-50A C

137 92 25 VS6

-0.14 0

<TS 681 E-50A C

137 92 17 VS6 0.94 0

<TS 682 E-50A C

137 92 18 08C

-0.84 0

<TS 683 E-50A C

137 92 25 08C 0.9 0

<TS 684 E-50A C

137 92 16 07C

-0.91 0

<TS 685 E-50A C

137 92 29 05C 0.03 0

<TS 686 E-5OA C

137 92 15 04C 0.77 0

<TS 687 E-50A C

137 92 18 02C 0.79 0

<TS 20

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 688 E-50A C

54 93 15 02C 0.91" 0

<TS 689 E-50A C

90 93 21 03C 0.62 0

<TS 690 E-50A C

132 93 28 VS2 0.73 0

<TS 691 E-50A C

53 94 14 03C 0.09 0

<TS 692 E-50A C

79 94 11 03C

-1.1 0

<TS 693 E-50A C

91 94 14 05H 0

0

<TS 694 E-50A C

129 94 18 VS4 0.86 0

<TS 695 E-50A C

131 94 15 08H

-0.77 0

<TS 696 E-50A C

131 94 19 08H 1.04 0

<TS 697 E-50A C

133 94 19 VS2 0.89 0

<TS 698 E-50A C

135 94 16 VS6

-0.67 0

<TS 699 E-50A C

135 94 23 VS6 0.97 0

<TS 700 E-50A C

135 94 25 VS7

-0.33 0

<TS 701 E-50A C

135 94 27 DBC

-1.19 0

<TS 702 E-50A C

90 95 21 06C 0.72 0

<TS 703 E-50A C

90 95 19 04C 0.69 0

<TS 704 E-50A C

94 95 18 07C

-0.9 0

<TS 705 E-50A C

130 95 24 VS4

-1.03 0

<TS 706 E-50A C

132 95 31 VS7 0.92 0

<TS 707 E-50A C

134 95 20 VS2 0.06 0

<TS 708 E-50A C

134 95 28 VS4

-0.89 0

<TS 709 E-50A C

134 95 9

VS4 1.16 0

<TS 710 E-50A C

134 95 31 VS6 1

0

<TS 711 E-50A C

134 95 28 VS7 0.86 0

<TS 712 E-50A C

49 96 16 03C 0.98 0

<TS 713 E-50A C

55 96 11 02C

-0.18 0

<TS 714 E-50A C

107 96 18 02H 0.87 0

<TS 715 E-50A C

131 96 22 06C 0.71 0

<TS 716 E-50A C

135 96 38 VS6 1.03 0

<TS 717 E-50A C

135 96 14 VS7

-0.49 0

<TS 718 E-50A C

135 96 18 VS7 1.1 0

<TS 719 E-50A C

48 97 29 VS4 0.8 0

<TS 720 E-50A C

52 97 16 02C

-0.95 0

<TS 721 E-50A C

76 97 12 04C 0.81 0

<TS 722 E-50A C

86 97 23 03H 0.98 0

<TS 723 E-50A C

96 97 13 05C 0.84 0

<TS 724 E-50A C

104 97 22 04C

-1.06 0

<TS 725 E-50A C

118 97 19 VS2

-0.85 0

<TS 726 E-50A C

132 97 11 08C 0.12 0

<TS 727 E-50A C

107 98 12 04C

-0.17 0

<TS 728 E-50A C

109 98 30 VS2

-0.85 0

<TS 729 E-50A C

80 99 11 07C 1

0

<TS 730 E-50A C

84 99 20 VS2

-0.91 0

<TS 731 E-50A C

92 99 7

07H

-0.87 0

<TS 732 E-50A C

104 99 17 06C 0.75 0

<TS 733 E-50A C

118 99 15 VS2 0.88 0

<TS 21

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 734 E-50A C

130 99 12 03C

-0.95 0

<TS 735 E-50A C

130 99 25 03C

-0.17 0

<TS 736 E-50A C

132 99 15 DBC 1.71 0

<TS 737 E-50A C

132 99 12 06C 0.94 0

<TS 738 E-50A C

134 99 17 04C

-1.01 0

<TS 739 E-50A C

75 100 10 03H

-1.02 0

<TS 740 E-50A C

75 100 17 03H 1.08 0

<TS 741 E-50A C

77 100 19 05H

-0.05 0

<TS 742 E-50A C

79 100 14 03H 1.15 0

<TS 743 E-50A C

79 100 11 05H 1.11 0

<TS 744 E-50A C

81 100 14 05H 0.96 0

<TS 745 E-50A C

83 100 22 04H 0.93 0

<TS 746 E-50A C

87 100 18 04H 1.01 0

<TS 747 E-50A C

93 100 18 VS2

-0.7 0

<TS 748 E-50A C

103 100 14 05C

-1.01 0

<TS 749 E-50A C

135 100 20 VS6

-0.78 0

<TS 750 E-50A C

135 100 32 VS7

-0.49 0

<TS 751 E-50A C

135 100 11 DBC

-1.75 0

<TS 752 E-50A C

135 100 20 DBC 1.63 0

<TS 753 E-50A C

135 100 15 04C

-0.99 0

<TS 754 E-50A C

135 100 20 02C 0.9 0

<TS 755 E-50A C

76 101 17 02H

-0.73 0

<TS 756 E-50A C

86 101 19 04H

-0.78 0

<TS 757 E-50A C

90 101 17 02C 0.17 0

<TS 758 E-50A C

92 101 17 VS2

-0.78 0

<TS 759 E-50A C

92 101 16 VS2 0.94 0

<TS 760 E-50A C

94 101 23 04C

-1.01 0

<TS 761 E-50A C

106 101 19 04H 1.01 0

<TS 762 E-50A C

118 101 14 04H 0.03 0

<TS 763 E-50A C

118 101 14 VS4 0.93 0

<TS 764 E-50A C

128 101 17 VS2

-0.72 0

<TS 765 E-50A C

51 102 5

03C

-0.29 0

<TS 766 E-50A C

51 102 16 03C 0.87 0

<TS 767 E-50A C

69 102 15 04H 0.86 0

<TS 768 E-50A C

81 102 19 07C

-1.07 0

<TS 769 E-50A C

81 102 12 07C

-0.14 0

<TS 770 E-50A C

83 102 18 05C

-0.28 0

<TS 771 E-50A C

87 102 22 05H 0.98 0

<TS 772 E-50A C

103 102 16 03C

-0.2 0

<TS 773 E-50A C

105 102 15 VS6 0.8 0

<TS 774 E-50A C

96 103 14 05C 0.93 0

<TS 775 E-50A C

98 103 18 06C

-0.86 0

<TS 776 E-50A C

98 103 20 04C

-0.99 0

<TS 777 E-50A C

98 103 14 04C 0.9 0

<TS 778 E-50A C

100 103 20 02C 0.88 0

<TS 779 E-50A C

104 103 12 DBC

-1.45 0

<TS 22

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 780 E-50A C

112 103 5

04H 0.13 0

<TS 781 E-50A C

112 103 16 04H 0.97 0

<TS 782 E-50A C

112 103 13 VS2

-0.59 0

<TS 783 E-50A C

126 103 9

VS2 0.88 0

<TS 784 E-50A C

126 103 32 VS4

-1 0

<TS 785 E-50A C

128 103 12 VS2 1

0

<TS 786 E-50A C

134 103 16 DBC

-1.67 0

<TS 787 E-50A C

134 103 16 02C

-0.94 0

<TS 788 E-50A C

39 104 12 04H 0.87 0

<TS 789 E-50A C

39 104 15 03C

-0.63 0

<TS 790 E-50A C

53 104 15 03C 0.91 0

<TS 791 E-50A C

63 104 13 04C

-0.14 0

<TS 792 E-50A C

63 104 18 03C 0.99 0

<TS 793 E-50A C

79 104 5

05H

-0.27 0

<TS 794 E-50A C

79 104 14 05H 0.88 0

<TS 795 E-50A C

87 104 11 06H 0.93 0

<TS 796 E-50A C

93 104 33 VS4

-0.42 0

<TS 797 E-50A C

93 104 13 VS6

-0.76 0

<TS 798 E-50A C

93 104 25 VS6 0.91 0

<TS 799 E-50A C

99 104 17 02C

-0.85 0

<TS 800 E-50A C

99 104 13 02C 0.14 0

<TS 801 E-50A C

101 104 14 05C

-0.06 0

<TS 802 E-50A C

111 104 12 04C

-0.17 0

<TS 803 E-50A C

121 104 14 VS4 0.85 0

<TS 804 E-50A C

121 104 14 VS6

-0.59 0

<TS 805 E-50A C

121 104 11 VS6 0.23 0

<TS 806 E-50A C

133 104 12 08C

-0.47 0

<TS 807 E-50A C

133 104 13 08C 0.86 0

<TS 808 E-50A C

133 104 14 07C 0.75 0

<TS 809 E-50A C

133 104 14 06C

-0.17 0

<TS 810 E-50A C

133 104 10 05C 0.03 0

<TS 811 E-50A C

133 104 15 05C 0.87 0

<TS 812 E-50A C

54 105 16 02C 0.94 0

<TS 813 E-50A C

90 105 22 05C 0.95 0

<TS 814 E-50A C

96 105 17 VS6

-0.94 0

<TS 815 E-50A C

98 105 20 05C

-1.02 0

<TS 816 E-50A C

98 105 22 04C 0.91 0

<TS 817 E-50A C

116 105 26 VS4

-1.11 0

<TS 818 E-50A C

122 105 14 04C 0

0

<TS 819 E-50A C

37 106 21 03C

-0.96 0

<TS 820 E-50A C

43 106 17 03C 0.73 0

<TS 821 E-50A C

55 106 11 06H 1.03 0

<TS 822 E-50A C

59 106 17 02C 0.78 0

<TS 823 E-50A C

65 106 19 04C 0.88 0

<TS 824 E-50A C

65 106 14 03C 0.96 0

<TS 825 E-50A C

65 106 16 02C 0.85 0

<TS 23

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 826 E-50A C

67 106 15 05C 0.95 0

<TS 827 E-50A C

69 106 13 VS5 1.19 0

<TS 828 E-50A C

93 106 22 VS2

-0.46 0

<TS 829 E-50A C

97 106 24 VS4

-0.83 0

<TS 830 E-50A C

97 106 16 VS4 0.91 0

<TS 831 E-50A C

101 106 16 04C 0.85 0

<TS 832 E-50A C

127 106 17 VS4

-0.61 0

<TS 833 E-50A C

66 107 19 03H 0.03 0

<TS 834 E-50A C

66 107 15 02C

-0.97 0

<TS 835 E-50A C

68 107 12 03H

-0.21 0

<TS 836 E-50A C

70 107 16 04C

-0.93 0

<TS 837 E-50A C

80 107 22 DBH 1.77 0

<TS 838 E-50A C

90 107 13 05C 0.19 0

<TS 839 E-50A C

90 107 18 05C 0.76 0

<TS 840 E-50A C

100 107 15 VS4

-0.88 0

<TS 841 E-50A C

100 107 9

VS4 1.06 0

<TS 842 E-50A C

100 107 7

04C

-0.19 0

<TS 843 E-50A C

100 107 15 04C 0.95 0

<TS 844 E-50A C

124 107 15 VS2

-0.59 0

<TS 845 E-50A C

128 107 17 03C 0.78 0

<TS 846 E-50A C

128 107 16 02C 0.98 0

<TS 847 E-50A C

130 107 17 03C

-0.3 0

<TS 848 E-50A C

130 107 20 02C 0.81 0

<TS 849 E-50A C

132 107 15 03C

-0.97 0

<TS 850 E-50A C

132 107 14 03C 0.75 0

<TS 851 E-50A C

41 108 15 03C 0.89 0

<TS 852 E-50A C

45 108 21 03C 0.98 0

<TS 853 E-50A C

65 108 17 03H

-0.88 0

<TS 854 E-50A C

69 108 16 04H 0.94 0

<TS 855 E-50A C

71 108 15 05C 0.95 0

<TS 856 E-50A C

71 108 15 04C 0.08 0

<TS 857 E-50A C

71 108 17 02C

-0.14 0

<TS 858 E-50A C

89 108 25 06H 0.93 0

<TS 859 E-50A C

103 108 18 07C

-0.22 0

<TS 860 E-50A C

103 108 8

07C 0.71 0

<TS 861 E-50A C

127 108 18 05C

-0.9 0

<TS 862 E-50A C

129 108 15 08C 0.8 0

<TS 863 E-50A C

44 109 17 DBH

-2.19 0

<TS 864 E-50A C

44 109 18 03C 0.03 0

<TS 865 E-50A C

66 109 14 03H

-0.83 0

<TS 866 E-50A C

66 109 15 04C 0.11 0

<TS 867 E-50A C

66 109 15 04C 0.94 0

<TS 868 E-50A C

66 109 20 02C 0.97 0

<TS 869 E-50A C

92 109 13 05C

-0.91 0

<TS 870 E-50A C

98 109 17 05C 1

0

<TS 871 E-50A C

104 109 18 VS6

-0.71 0

<TS 24

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 872 E-50A C

110 109 14 05C 0.82 0

<TS 873 E-50A C

126 109 11 05C 0

0

<TS 874 E-50A C

126 109 16 05C 0.9 0

<TS 875 E-50A C

126 109 14 03C 0.15 0

<TS 876 E-50A C

47 110 18 VS4

-0.72 0

<TS 877 E-50A C

57 110 11 02C

-0.2 0

<TS 878 E-50A C

57 110 16 02C 0.85 0

<TS 879 E-50A C

71 110 15 04H 0.88 0

<TS 880 E-50A C

95 110 14 02C

-0.88 0

<TS 881 E-50A C

101 110 15 VS2 0.17 0

<TS 882 E-50A C

101 110 18 VS2 0.76 0

<TS 883 E-50A C

111 110 17 VS4

-0.86 0

<TS 884 E-50A C

117 110 14 03C 1.02 0

<TS 885 E-50A C

119 110 20 04C

-0.93 0

<TS 886 E-50A C

123 110 12 VS2 0.99 0

<TS 887 E-50A C

125 110 22 03C 1.02 0

<TS 888 E-50A C

127 110 28 VS2

-0.93 0

<TS 889 E-50A C

127 110 17 VS2 1.12 0

<TS 890 E-50A C

127 110 13 VS4

-0.9 0

<TS 891 E-50A C

127 110 13 VS4

-0.2 0

<TS 892 E-50A C

129 110 19 04C 0.03 0

<TS 893 E-50A C

129 110 25 02C 0.88 0

<TS 894 E-50A C

46 111 8

02C

-0.99 0

<TS 895 E-50A C

46 111 14 02C 0.93 0

<TS 896 E-50A C

48 111 15 02C 0.94 0

<TS 897 E-50A C

52 111 21 02C 0.88 0

<TS 898 E-50A C

76 111 13 05C 0.9 0

<TS 899 E-50A C

76 111 17 04C 0.82 0

<TS 900 E-50A C

86 111 18 05C 0.78 0

<TS 901 E-50A C

96 111 21 05C 0.84 0

<TS 902 E-50A C

96 111 15 04C 0.16 0

<TS 903 E-50A C

96 111 16 04C 0.82 0

<TS 904 E-50A C

98 111 16 07H 0.18 0

<TS 905 E-50A C

98 111 11 VS2

-0.18 0

<TS 906 E-50A C

98 111 17 VS2 0.51 0

<TS 907 E-50A C

106 111 18 DBC 1.59 0

<TS 908 E-50A C

122 111 17 05C

-0.93 0

<TS 909 E-50A C

126 111 13 VS6

-0.87 0

<TS 910 E-50A C

126 111 18 VS7 0.82 0

<TS 911 E-50A C

126 111 13 07C 0.76 0

<TS 912 E-50A C

126 111 15 03C

-0.95 0

<TS 913 E-50A C

126 111 13 02C

-1.06 0

<TS 914 E-50A C

128 111 19 05C 0.7 0

<TS 915 E-50A C

49 112 22 VS4

-0.73 0

<TS 916 E-50A C

83 112 18 02C

-0.27 0

<TS 917 E-50A C

89 112 16 05H

-0.94 0

<TS 25

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 918 E-50A C

89 112 16 05H 0.23 0

<TS 919 E-50A C

89 112 16 05H 0.83 0

<TS 920 E-50A C

99 112 20 04C 0.71 0

<TS 921 E-50A C

105 112 21 05H 1.02 0

<TS 922 E-50A C

123 112 16 03C 0.72 0

<TS 923 E-50A C

125 112 23 07H

-0.1 0

<TS 924 E-50A C

125 112 12 04C

-1.11 0

<TS 925 E-50A C

125 112 19 03C

-0.05 0

<TS 926 E-50A C

127 112 28 03C

-1.09 0

<TS 927 E-50A C

66 113 16 03H 0.81 0

<TS 928 E-50A C

66 113 14 02C 0.85 0

<TS 929 E-50A C

78 113 20 02C 0.85 0

<TS 930 E-50A C

126 113 27 VS4

-0.67 0

<TS 931 E-50A C

126 113 31 VS4 0

0

<TS 932 E-50A C

126 113 17 VS6 0

0

<TS 933 E-50A C

126 113 24 VS6 1.13 0

<TS 934 E-50A C

55 114 15 02C 0.88 0

<TS 935 E-50A C

67 114 25 02C 0.99 0

<TS 936 E-50A C

77 114 16 04H 0.94 0

<TS 937 E-50A C

91 114 18 VS2

-0.76 0

<TS 938 E-50A C

97 114 16 VS4

-0.83 0

<TS 939 E-50A C

38 115 6

02C

-1.13 0

<TS 940 E-50A C

38 115 14 02C 0.91 0

<TS 941 E-50A C

56 115 19 02C 0.85 0

<TS 942 E-50A C

90 115 19 VS2

-0.89 0

<TS 943 E-50A C

90 115 18 VS6

-0.63 0

<TS 944 E-50A C

100 115 17 05H

-0.75 0

<TS 945 E-50A C

102 115 19 VS2

-0.72 0

<TS 946 E-50A C

102 115 21 VS2

-0.08 0

<TS 947 E-50A C

108 115 18 05H 0.97 0

<TS 948 E-50A C

120 115 16 04C 0.69 0

<TS 949 E-50A C

126 115 15 05H 0.99 0

<TS 950 E-50A C

126 115 17 VS6

-0.89 0

<TS 951 E-50A C

126 115 20 04C 0.69 0

<TS 952 E-50A C

126 115 21 02C

-1.03 0

<TS 953 E-50A C

126 115 12 02C 0.03 0

<TS 954 E-50A C

37 116 18 03C 0.9 0

<TS 955 E-50A C

65 116 15 VS3 0.87 0

<TS 956 E-50A C

87 116 21 04C 0.79 0

<TS 957 E-50A C

87 116 7

03C

-0.85 0

<TS 958 E-50A C

87 116 16 03C

-0.06 0

<TS 959 E-50A C

91 116 28 VS2

-0.98 0

<TS 960 E-50A C

93 116 10 04H 0.99 0

<TS 961 E-50A C

97 116 21 VS4

-0.88 0

<TS 962 E-50A C

97 116 21 05C 0.73 0

<TS 963 E-50A C

109 116 18 04H

-0.66 0

<TS 26

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 964 E-50A C

111 116 17 03C 0.84 0

<TS 965 E-50A C

121 116 21 03C 0.59 0

<TS 966 E-50A C

52 117 23 02C 0.85 0

<TS 967 E-50A C

102 117 21 03H 0.97 0

<TS 968 E-50A C

106 117 16 06C

-1.17 0

<TS 969 E-50A C

108 117 15 05C 0.97 0

<TS 970 E-50A C

120 117 15 04C 0.66 0

<TS 971 E-50A C

122 117 13 VS1 1

0

<TS 972 E-50A C

124 117 16 03C 0.09 0

<TS 973 E-50A C

51 118 18 02C

-0.88 0

<TS 974 E-50A C

53 118 16 02C 0.82 0

<TS 975 E-50A C

59 118 11 02C

-0.14 0

<TS 976 E-50A C

59 118 14 02C 0.91 0

<TS 977 E-50A C

63 118 20 03C 0.89 0

<TS 978 E-50A C

67 118 17 03C 0.76 0

<TS 979 E-50A C

97 118 24 VS4 0.65 0

<TS 980 E-50A C

109 118 17 04C

-0.9 0

<TS 981 E-50A C

113 118 17 04C 0.08 0

<TS 982 E-50A C

121 118 32 VS4

-0.8 0

<TS 983 E-50A C

121 118 29 03C 0.96 0

<TS 984 E-50A C

54 119 15 02C 0.93 0

<TS 985 E-50A C

60 119 23 02C 0.93 0

<TS 986 E-50A C

100 119 24 VS2

-0.63 0

<TS 987 E-50A C

100 119 27 VS2 0.05 0

<TS 988 E-50A C

100 119 13 VS2 0.79 0

<TS 989 E-50A C

100 119 18 VS4

-0.9 0

<TS 990 E-50A C

100 119 16 VS6 0.84 0

<TS 991 E-50A C

102 119 21 04H 0.88 0

<TS 992 E-50A C

106 119 13 VS4 0.9 0

<TS 993 E-50A C

114 119 14 07C 0.71 0

<TS 994 E-50A C

114 119 13 03C 0.67 0

<TS 995 E-50A C

116 119 22 03C 0.72 0

<TS 996 E-50A C

120 119 25 03C 0.7 0

<TS 997 E-50A C

124 119 12 02C

-0.92 0

<TS 998 E-50A C

39 120 21 04H 0.86 0

<TS 999 E-50A C

55 120 15 02C

-0.3 0

<TS 1000 E-50A C

67 120 13 06H

-0.13 0

<TS 1001 E-50A C

67 120 18 VS5 0.69 0

<TS 1002 E-50A C

75 120 18 03C 0.85 0

<TS 1003 E-50A C

79 120 13 04H 0.89 0

<TS 1004 E-50A C

87 120 18 VS2 0.11 0

<TS 1005 E-50A C

87 120 20 VS2 0.96 0

<TS 1006 E-50A C

97 120 16 VS2

-0.83 0

<TS 1007 E-50A C

97 120 29 VS2 0.91 0

<TS 1008 E-50A C

101 120 13 03C 0.71 0

<TS 1009 E-50A C

107 120 17 DBH 1.98 0

<TS 27

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 1010 E-50A C

109 120 23 03C

-0.24 0

<TS 1011 E-50A C

117 120 14 03H 1.03 0

<TS 1012 E-50A C

117 120 15 02C 0.68 0

<TS 1013 E-50A C

121 120 15 06H 0.81 0

<TS 1014 E-50A C

26 121 19 VS4

-0.63 0

<TS 1015 E-50A C

26 121 6

VS4

-0.12 0

<TS 1016 E-50A C

60 121 22 02C 0.79 0

<TS 1017 E-50A C

62 121 15 02C 0.91 0

<TS 1018 E-50A C

74 121 13 03H

-0.83 0

<TS 1019 E-50A C

82 121 11 05H 0.86 0

<TS 1020 E-50A C

96 121 18 VS6 1.14 0

<TS 1021 E-50A C

102 121 24 VS4

-0.62 0

<TS 1022 E-50A C

106 121 15 05C 0.03 0

<TS 1023 E-50A C

106 121 10 04C 0.03 0

<TS 1024 E-50A C

106 121 19 04C 0.93 0

<TS 1025 E-50A C

116 121 7

04C 0

0

<TS 1026 E-50A C

116 121 25 04C 0.99 0

<TS 1027 E-50A C

120 121 25 05C 0.91 0

<TS 1028 E-50A C

45 122 17 03C

-0.91 0

<TS 1029 E-50A C

47 122 26 VS4 0

0

<TS 1030 E-50A C

47 122 30 VS4 0.9 0

<TS 1031 E-50A C

49 122 12 04C

-0.88 0

<TS 1032 E-50A C

51 122 17 02C

-0.17 0

<TS 1033 E-50A C

53 122 13 04C 0.88 0

<TS 1034 E-50A C

53 122 23 02C

-0.17 0

<TS 1035 E-50A C

55 122 17 02C

-0.2 0

<TS 1036 E-50A C

63 122 22 03C 0.87 0

<TS 1037 E-50A C

103 122 22 DBC 1.5 0

<TS 1038 E-50A C

103 122 13 07C 0.94 0

<TS 1039 E-50A C

42 123 20 DBH 0.03 0

<TS 1040 E-50A C

44 123 17 06H 0

0

<TS 1041 E-50A C

44 123 22 VS4

-0.6 0

<TS 1042 E-50A C

44 123 22 VS4

-0.06 0

<TS 1043 E-50A C

44 123 15 VS4 0.81 0

<TS 1044 E-50A C

50 123 20 04C 0.17 0

<TS 1045 E-50A C

64 123 18 04C 0.79 0

<TS 1046 E-50A C

104 123 18 04C 0.74 0

<TS 1047 E-50A C

108 123 18 VS2

-0.96 0

<TS 1048 E-50A C

110 123 16 08H

-0.83 0

<TS 1049 E-50A C

114 123 21 03C

-1.03 0

<TS 1050 E-50A C

116 123 18 06C

-0.11 0

<TS 1051 E-50A C

120 123 18 01H 0.03 0

<TS 1052 E-50A C

33 124 18 03C 0.91 0

<TS 1053 E-50A C

45 124 24 VS4 0.87 0

<TS 1054 E-50A C

47 124 14 VS4

-0.79 0

<TS 1055 E-50A C

47 124 23 VS4 0.03 0

<TS 28

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 1056 E-50A C

47 124 24 VS4 0.76 0

<TS 1057 E-50A C

63 124 12 04C

-0.09 0

<TS 1058 E-50A C

63 124 17 04C 0.88 0

<TS 1059 E-50A C

87 124 14 04C

-0.94 0

<TS 1060 E-50A C

95 124 19 VS2

-0.8 0

<TS 1061 E-50A C

95 124 20 VS2 0.77 0

<TS 1062 E-50A C

107 124 17 VS2

-0.08 0

<TS 1063 E-50A C

119 124 15 VS4

-0.81 0

<TS 1064 E-50A C

119 124 9

VS4 0.6 0

<TS 1065 E-50A C

46 125 14 VS4

-0.11 0

<TS 1066 E-50A C

46 125 14 VS4 0.22 0

<TS 1067 E-50A C

46 125 15 VS4 0.81 0

<TS 1068 E-50A C

48 125 25 02C 0.08 0

<TS 1069 E-50A C

92 125 12 03H 0.87 0

<TS 1070 E-50A C

110 125 20 VS2 0.71 0

<TS 1071 E-50A C

118 125 20 VS7

-0.88 0

<TS 1072 E-50A C

31 126 20 VS4

-0.45 0

<TS 1073 E-50A C

39 126 20 03C 0.85 0

<TS 1074 E-50A C

43 126 30 VS4 0.93 0

<TS 1075 E-50A C

43 126 15 DBC 1.52 0

<TS 1076 E-50A C

47 126 25 VS4

-0.74 0

<TS 1077 E-50A C

47 126 25 VS4 0.03 0

<TS 1078 E-50A C

47 126 14 04C 0.11 0

<TS 1079 E-50A C

51 126 19 02C 0.09 0

<TS 1080 E-50A C

51 126 13 02C 0.79 0

<TS 1081 E-50A C

59 126 11 06H 0.85 0

<TS 1082 E-50A C

63 126 17 04C 0.76 0

<TS 1083 E-50A C

71 126 11 05C 0.11 0

<TS 1084 E-50A C

71 126 21 05C 0.71 0

<TS 1085 E-50A C

97 126 15 VS4 0.17 0

<TS 1086 E-50A C

111 126 17 04C 0.94 0

<TS 1087 E-50A C

2 127 22 05C 0.74 0

<TS 1088 E-50A H

2 127 14 DBH 0.57 0

<TS 1089 E-50A C

38 127 17 03H 0.93 0

<TS 1090 E-50A C

44 127 17 03C

-0.34 0

<TS 1091 E-50A C

50 127 13 03C

-0.82 0

<TS 1092 E-50A C

50 127 9

03C 0.17 0

<TS 1093 E-50A C

52 127 13 VS5

-1.11 0

<TS 1094 E-50A C

58 127 9

04C 0.09 0

<TS 1095 E-50A C

58 127 24 04C 0.88 0

<TS 1096 E-50A C

72 127 20 04C 0.81 0

<TS 1097 E-50A C

98 127 21 07H 1.01 0

<TS 1098 E-50A C

31 128 18 VS4

-0.76 0

<TS 1099 E-50A C

31 128 23 VS4 0.96 0

<TS 1100 E-50A C

37 128 21 VS4 0.94 0

<TS 1101 E-50A C

45 128 14 03H 0

0

<TS 29

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 1102 E-50A C

79 128 24 04C 0.91 0

<TS 1103 E-50A C

89 128 14 05H 0.89 0

<TS 1104 E-50A C

107 128 15 04C

-1.09 0

<TS 1105 E-50A C

111 128 21 03C

-0.93 0

<TS 1106 E-50A C

111 128 16 03C 0.83 0

<TS 1107 E-50A C

44 129 13 03C 0.92 0

<TS 1108 E-50A C

114 129 16 08H

-1.15 0

<TS 1109 E-50A C

114 129 23 VS4

-0.71 0

<TS 1110 E-50A C

39 130 12 DBC

-1.46 0

<TS 1111 E-50A C

81 130 19 VS3

-0.68 0

<TS 1112 E-50A C

83 130 10 VS2 0.89 0

<TS 1113 E-50A C

93 130 12 03H

-0.69 0

<TS 1114 E-50A C

93 130 22 VS2

-0.7 0

<TS 1115 E-50A C

93 130 15 VS2 0.89 0

<TS 1116 E-50A C

93 130 22 VS4

-0.93 0

<TS 1117 E-50A C

93 130 37 VS4 1.01 0

<TS 1118 E-50A C

95 130 13 04H 1.02 0

<TS 1119 E-50A C

95 130 20 VS2 0.79 0

<TS 1120 E-50A C

107 130 23 VS2

-0.76 0

<TS 1121 E-50A C

111 130 22 04C

-0.09 0

<TS 1122 E-50A C

113 130 21 VS4

-0.98 0

<TS 1123 E-50A C

113 130 24 VS4

-0.58 0

<TS 1124 E-50A C

34 131 13 05C

-0.26 0

<TS 1125 E-50A C

44 131 14 05C 0.86 0

<TS 1126 E-50A C

76 131 10 VS4 0.94 0

<TS 1127 E-50A C

92 131 13 04H 0.96 0

<TS 1128 E-50A C

96 131 22 04C

-1.1 0

<TS 1129 E-50A C

100 131 15 05C 0.95 0

<TS 1130 E-50A C

110 131 26 DBH

-1.77 0

<TS 1131 E-50A C

110 131 20 03C 0.89 0

<TS 1132 E-50A C

27 132 20 02H 0.41 0

<TS 1133 E-50A C

31 132 14 VS4 0.88 0

<TS 1134 E-50A C

49 132 17 02C 0.79 0

<TS 1135 E-50A C

95 132 20 VS2 0.95 0

<TS 1136 E-50A C

95 132 13 VS4 1.03 0

<TS 1137 E-50A C

97 132 17 VS4 1.02 0

<TS 1138 E-50A C

105 132 21 03C 0.85 0

<TS 1139 E-50A C

109 132 20 04C 0.9 0

<TS 1140 E-50A C

92 133 19 07H 0.92 0

<TS 1141 E-50A C

92 133 23 04C 0.93 0

<TS 1142 E-50A C

102 133 14 03C

-1.08 0

<TS 1143 E-50A C

102 133 11 03C 0.68 0

<TS 1144 E-50A C

104 133 14 05C

-0.28 0

<TS 1145 E-50A C

106 133 21 DBC 1.7 0

<TS 1146 E-50A C

108 133 17 04C

-0.95 0

<TS 1147 E-50A C

108 133 15 04C 0.81 0

<TS 30

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 1148 E-50A C

45 134 18 03C 0.94 0

<TS 1149 E-50A C

63 134 14 03C 0.73 0

<TS 1150 E-50A C

69 134 17 06C

-0.96 0

<TS 1151 E-50A C

71 134 13 VS3

-0.66 0

<TS 1152 E-50A C

73 134 16 06C

-0.9 0

<TS 1153 E-50A C

95 134 25 04C

-0.91 0

<TS 1154 E-50A C

95 134 15 03C

-1.07 0

<TS 1155 E-50A C

97 134 11 VS2 0.92 0

<TS 1156 E-50A C

97 134 12 VS4

-0.73 0

<TS 1157 E-50A C

97 134 19 VS4 0.96 0

<TS 1158 E-50A C

103 134 16 04C 0.11 0

<TS 1159 E-50A C

103 134 15 04C 0.68 0

<TS 1160 E-50A C

107 134 24 VS4

-0.91 0

<TS 1161 E-50A C

107 134 16 VS4 0.79 0

<TS 1162 E-50A C

107 134 27 02C

-1.03 0

<TS 1163 E-50A C

48 135 21 01C

-0.11 0

<TS 1164 E-50A C

82 135 14 VS3

-0.84 0

<TS 1165 E-50A C

90 135 12 04H 0.95 0

<TS 1166 E-50A C

90 135 18 04C 0.89 0

<TS 1167 E-50A C

92 135 17 04C 0.82 0

<TS 1168 E-50A C

98 135 14 03C 0.05 0

<TS 1169 E-50A C

102 135 18 04C 0.76 0

<TS 1170 E-50A C

102 135 19 03C

-0.34 0

<TS 1171 E-50A C

104 135 27 03C 0.82 0

<TS 1172 E-50A C

106 135 25 VS4

-0.62 0

<TS 1173 E-50A C

67 136 20 VS3 0.86 0

<TS 1174 E-50A C

69 136 16 VS3

-0.7 0

<TS 1175 E-50A C

69 136 17 VS5 0.86 0

<TS 1176 E-50A C

93 136 20 03C

-0.91 0

<TS 1177 E-50A C

93 136 17 03C 0.85 0

<TS 1178 E-50A C

95 136 19 VS2

-0.87 0

<TS 1179 E-50A C

95 136 24 VS2 0.82 0

<TS 1180 E-50A C

101 136 11 03C

-0.98 0

<TS 1181 E-50A C

101 136 16 02C 0.05 0

<TS 1182 E-50A C

12 137 13 02H

-0.87 0

<TS 1183 E-50A C

56 137 17 03C

-0.03 0

<TS 1184 E-50A C

90 137 19 06C 0.91 0

<TS 1185 E-50A C

100 137 13 VS4

-0.67 0

<TS 1186 E-50A C

100 137 17 05C

-0.98 0

<TS 1187 E-50A C

100 137 16 04C 0.87 0

<TS 1188 E-50A C

100 137 21 03C

-0.9 0

<TS 1189 E-50A C

100 137 27 03C

-0.03 0

<TS 1190 E-50A C

65 138 30 04C

-0.14 0

<TS 1191 E-50A C

91 138 9

04C

-1.06 0

<TS 1192 E-50A C

91 138 16 04C 0.82 0

<TS 1193 E-50A C

97 138 18 02C 0.74 0

<TS 31

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 1194 E-50A C

99 138 16 VS4 0

0

<TS 1195 E-50A C

99 138 17 VS4 0.68 0

<TS 1196 E-50A C

99 138 18 02C

-0.99 0

<TS 1197 E-50A C

99 138 15 02C 0.14 0

<TS 1198 E-50A C

101 138 21 VS4 0.74 0

<TS 1199 E-50A C

68 139 30 VS3

-0.67 0

<TS 1200 E-50A C

68 139 17 VS5

-0.9 0

<TS 1201 E-50A C

68 139 35 VS5 0.84 0

<TS 1202 E-50A C

98 139 16 02C

-0.16 0

<TS 1203 E-50A C

100 139 19 VS4

-0.59 0

<TS 1204 E-50A C

100 139 16 03C

-0.19 0

<TS 1205 E-50A C

55 140 22 06C

-0.27 0

<TS 1206 E-50A C

95 140 22 04C 0.71 0

<TS 1207 E-50A C

99 140 26 VS4

-0.67 0

<TS 1208 E-50A C

99 140 14 03C

-0.95 0

<TS 1209 E-50A C

99 140 18 03C

-0.14 0

<TS 1210 E-50A C

68 141 22 DBH 2.13 0

<TS 1211 E-50A C

82 141 22 VS3

-0.81 0

<TS 1212 E-50A C

84 141 22 04C 0.88 0

<TS 1213 E-50A C

92 141 16 02C

-0.4 0

<TS 1214 E-50A C

94 141 18 03C 0.92 0

<TS 1215 E-50A C

63 142 16 04C 0.87 0

<TS 1216 E-50A C

95 142 23 02C 0.6 0

<TS 1217 E-50A C

54 143 11 04C 0.8 0

<TS 1218 E-50A C

58 143 15 03C 0.84 0

<TS 1219 E-50A C

72 143 20 DBC 1.87 0

<TS 1220 E-50A C

86 143 16 03C

-1.03 0

<TS 1221 E-50A C

90 143 21 03C

-1 0

<TS 1222 E-50A C

90 143 14 03C

-0.08 0

<TS 1223 E-50A C

90 143 25 02C

-1.05 0

<TS 1224 E-50A C

90 143 22 02C 0.05 0

<TS 1225 E-50A C

59 144 15 04C 0.82 0

<TS 1226 E-50A C

61 144 14 DBH 1.56 0

<TS 1227 E-50A C

79 144 15 VS5

-0.84 0

<TS 1228 E-50A C

79 144 22 VS5 0.93 0

<TS 1229 E-50A C

87 144 20 03C

-0.8 0

<TS 1230 E-50A C

91 144 15 VS4 0.63 0

<TS 1231 E-50A C

32 145 21 VS4

-0.94 0

<TS 1232 E-50A C

70 145 14 DBC

-1.59 0

<TS 1233 E-50A C

86 145 18 04C 0.82 0

<TS 1234 E-50A C

88 145 20 VS4 0.79 0

<TS 1235 E-50A C

88 145 23 04C

-1.01 0

<TS 1236 E-50A C

88 145 32 02C 0.14 0

<TS 1237 E-50A C

11 146 15 03C 0.86 0

<TS 1238 E-50A C

85 146 24 03C

-0.71 0

<TS 1239 E-50A C

87 146 19 VS4

-0.99 0

<TS 32

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 1240 E-50A C

87 146 21 VS4 0.38 0

<TS 1241 E-50A C

40 147 27 VS4

-0.99 0

<TS 1242 E-50A C

40 147 23 VS4

-0.37 0

<TS 1243 E-50A C

66 147 13 03C

-0.16 0

<TS 1244 E-50A C

80 147 19 07H 0.82 0

<TS 1245 E-50A C

84 147 22 VS3 0.93 0

<TS 1246 E-50A C

77 148 17 07H

-0.94 0

<TS 1247 E-50A C

77 148 23 03C 0.8 0

<TS 1248 E-50A C

79 148 13 02C 1.02 0

<TS 1249 E-50A C

81 148 20 05C

-0.06 0

<TS 1250 E-50A C

83 148 20 03C

-0.98 0

<TS 1251 E-50A C

8 149 18 05H 0.76 0

<TS 1252 E-50A C

52 149 18 VS3 1.05 0

<TS 1253 E-50A C

52 149 13 VS4

-0.93 0

<TS 1254 E-50A C

72 149 21 DBH 1.95 0

<TS 1255 E-50A C

80 149 17 VS4

-0.75 0

<TS 1256 E-50A C

1 150 21 02C 0.83 0

<TS 1257 E-50A C

1 150 14 0iC

-0.4 0

<TS 1258 E-50A C

75 150 14 04C 0.96 0

<TS 1259 E-50A C

75 150 14 02C 0.96 0

<TS 1260 E-50A C

77 150 17 02C 0.89 0

<TS 1261 E-50A C

79 150 19 VS4 0.97 0

<TS 1262 E-50A C

79 150 18 02C

-0.03 0

<TS 1263 E-50A C

79 150 14 02C 0.74 0

<TS 1264 E-50A C

65 152 22 VS3 0.9 0

<TS 1265 E-50A C

69 152 24 VS3

-0.82 0

<TS 1266 E-50A C

69 152 22 VS3 0.94 0

<TS 1267 E-50A C

70 153 23 VS3

-0.84 0

<TS 1268 E-50A C

67 154 15 04C 0.8 0

<TS 1269 E-50A C

67 154 18 02C 0.86 0

<TS 1270 E-50A C

50 157 33 VS3

-0.85 0

<TS 1271 E-50A C

50 157 21 VS3 1

0

<TS 1272 E-50A C

22 159 16 02H 0.81 0

<TS 1273 E-50A C

48 159 10 01H

-0.9 0

<TS 1274 E-50A C

48 159 14 01H

-0.21 0

<TS 1275 E-50A C

48 159 6

01H 0.78 0

<TS 1276 E-50A H

1 160 18 04H

-0.18 0

<TS 1277 E-50A C

24 161 17 02C 0.66 0

<TS 1278 E-50A C

32 161 19 DBC

-0.28 0

<TS 1279 E-50A C

29 162 15 01H

-0.85 0

<TS 1280 E-50A H

4 163 19 04H

-1.19 0

<TS 1281 E-50A C

24 163 20 02C 0.69 0

<TS 33 Steam Generator E-50B Indications NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 1

E-50B C

8 3

18 03C

-0.2 0

<TS 2

E-50B C

28 3

12 VS4

-0.8 0

<TS 3

E-50B C

35 4

29 DBC 1.84 0

<TS 4

E-50B C

22 5

18 VS4

-0.54 0

<TS 5

E-50B C

32 5

20 02C 1.03 0

<TS 6

E-50B C

40 5

20 02C

-0.81 0

<TS 7

E-50B C

43 6

16 02C

-0.9 0

<TS 8

E-50B C

43 6

25 02C

-0.23 0

<TS 9

E-50B C

45 6

22 02C

-0.91 0

<TS 10 E-50B C

45 6

20 02C

-0.08 0

<TS 11 E-50B C

46 7

20 01C

-0.11 0

<TS 12 E-50B C

46 7

6 01C 0.71 0

<TS 13 E-50B C

50 7

15 DBH 1.95 0

<TS 14 E-50B C

41 8

23 04C 0.84 0

<TS 15 E-50B C

49 8

25 VS4 0.59 0

<TS 16 E-50B C

53 8

15 01C 0.84 0

<TS 17 E-50B C

48 9

28 VS4

-0.79 0

<TS 18 E-50B C

48 9

27 VS4

-0.03 0

<TS 19 E-50B C

48 9

19 VS4 0.82 0

<TS 20 E-50B C

37 10 18 03C

-0.82 0

<TS 21 E-50B C

49 10 19 01C 0.87 0

<TS 22 E-50B C

34 11 18 VS4 0.81 0

<TS 23 E-50B C

33 12 14 VS4

-1.01 0

<TS 24 E-50B C

33 12 20 VS4 1.2 0

<TS 25 E-50B C

37 12 15 VS4

-0.9 0

<TS 26 E-50B C

41 12 16 VS4

-0.34 0

<TS 27 E-50B C

41 12 16 VS4 0.03 0

<TS 28 E-50B C

41 12 25 VS4 0.62 0

<TS 29 E-50B C

41 12 20 05C 0.14 0

<TS 30 E-50B C

47 12 15 VS4

-0.7 0

<TS 31 E-50B C

47 12 23 VS4 0.91 0

<TS 32 E-50B C

61 12 15 06H

-0.28 0

<TS 33 E-50B C

34 13 25 VS4 0.68 0

<TS 34 E-50B C

38 13 18 VS4 0.71 0

<TS 35 E-50B C

48 13 22 VS4

-0.34 0

<TS 36 E-50B C

48 13 27 VS4 0.23 0

<TS 37 E-50B C

48 13 21 VS4 0.76 0

<TS 38 E-50B C

41 14 24 VS4

-0.09 0

<TS 39 E-50B C

41 14 18 VS4 0.5 0

<TS 40 E-50B C

47 14 24 VS4 0.7 0

<TS 41 E-50B C

76 15 24 DBH 1.72 0

<TS 42 E-50B C

57 16 18 06H

-0.15 0

<TS 43 E-50B C

66 17 18 06H 0.68 0

<TS 44 E-50B C

72 17 22 DBH 1.6 0

<TS 45 E-50B C

74 17 21 VS3

-0.8 0

<TS 34

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 46 E-50B C

74 17 14 VS3 0.85 0

<TS 47 E-50B C

74 17 20 VS4

-0.98 0

<TS 48 E-50B C

80 17 30 DBH 1.6 0

<TS 49 E-50B C

84 19 24 07H

-1.08 0

<TS 50 E-50B C

47 20 25 VS4

-1.03 0

<TS 51 E-50B C

47 20 27 VS4 0.88 0

<TS 52 E-50B C

44 21 24 VS4

-1.01 0

<TS 53 E-50B C

44 21 29 VS4 0.84 0

<TS 54 E-50B C

66 21 18 06H 0.74 0

<TS 55 E-50B C

68 21 14 VS5

-1.06 0

<TS 56 E-50B C

76 21 18 VS4

-1.14 0

<TS 57 E-50B C

76 21 28 VS4 0.79 0

<TS 58 E-50B C

47 22 18 VS4

-0.18 0

<TS 59 E-50B C

77 22 23 01H

-0.34 0

<TS 60 E-50B C

81 22 24 VS3 0.84 0

<TS 61 E-50B C

81 22 21 VS4 0.67 0

<TS 62 E-50B C

91 22 25 VS6 0.94 0

<TS 63 E-50B C

30 23 13 VS4

-0.84 0

<TS 64 E-50B C

44 23 23 DBH

-1.75 0

<TS 65 E-50B C

44 23 19 VS4 0.95 0

<TS 66 E-50B C

46 23 18 VS4

-0.91 0

<TS 67 E-50B C

46 23 23 VS4 0.97 0

<TS 68 E-50B C

62 23 17 VS5 0.97 0

<TS 69 E-50B C

74 23 17 VS3

-0.8 0

<TS 70 E-50B C

74 23 15 VS4

-0.89 0

<TS 71 E-50B C

78 23 18 DBH

-1.57 0

<TS 72 E-50B C

75 24 14 DBC

-1.55 0

<TS 73 E-50B C

79 24 21 VS4

-0.04 0

<TS 74 E-50B C

79 24 26 VS4 0.6 0

<TS 75 E-50B C

81 24 19 VS3

-0.81 0

<TS 76 E-50B C

40 25 15 05H

-0.91 0

<TS 77 E-50B C

40 25 14 VS4

-0.84 0

<TS 78 E-50B C

46 25 15 VS4

-0.79 0

<TS 79 E-50B C

72 25 25 VS3

-0.64 0

<TS 80 E-50B C

27 26 17 05H 0.79 0

<TS 81 E-50B C

42 27 21 VS4

-0.34 0

<TS 82 E-50B C

44 27 24 VS4

-0.88 0

<TS 83 E-50B C

44 27 25 VS4 0.99 0

<TS 84 E-50B C

74 27 18 VS4

-0.84 0

<TS 85 E-50B C

76 27 9

06H

-0.91 0

<TS 86 E-50B C

98 27 18 04C

-0.78 0

<TS 87 E-50B C

100 27 24 VS4

-0.97 0

<TS 88 E-50B C

1 28 10 02C 1.01 0

<TS 89 E-50B C

83 28 22 VS6

-0.82 0

<TS 90 E-50B C

97 28 18 03C 1.02 0

<TS 91 E-50B C

44 29 27 VS4

-0.15 0

<TS 92 E-50B C

44 29 12 VS4 0.76 0

<TS 93 E-50B C

74 29 13 VS5

-0.94 0

<TS 35

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 94 E-50B C

76 29 15 VS3

-0.33 0

<TS 95 E-50B C

76 29 23 VS3 0.06 0

<TS 96 E-50B C

76 29 22 VS3 0.72 0

<TS 97 E-50B C

76 29 24 VS4 0.07 0

<TS 98 E-50B C

96 29 13 VS4 1:05 0

<TS 99 E-50B C

96 29 15 DBC

-1.85 0

<TS 100 E-50B C

100 29 20 VS6

-0.71 0

<TS 101 E-50B C

100 29 22 03C 0.97 0

<TS 102 E-50B C

102 29 15 04C 1

0

<TS 103 E-50B C

93 30 19 VS4

-0.6 0

<TS 104 E-50B C

101 30 15 04C 1.08 0

<TS 105 E-50B C

101 30 16 03C

-0.83 0

<TS 106 E-50B C

101 30 11 03C 0.97 0

<TS 107 E-50B C

101 30 10 02C 0.96 0

<TS 108 E-50B C

103 30 14 0iC 0.2 0

<TS 109 E-50B C

105 30 29 VS4 0.93 0

<TS 110 E-50B C

105 30 21 02C 0.8 0

<TS 111 E-50B C

34 31 22 VS4 0.62 0

<TS 112 E-50B C

40 31 19 VS4 0.53 0

<TS 113 E-50B C

44 31 34 VS4

-0.82 0

<TS 114 E-50B C

44 31 19 VS4 0.26 0

<TS 115 E-50B C

102 31 16 VS4 0.7 0

<TS 116 E-50B C

102 31 20 02C

-0.71 0

<TS 117 E-50B C

104 31 18 VS4 0.87 0

<TS 118 E-50B C

104 31 9

DBC

-1.6 0

<TS 119 E-50B C

104 31 16 02C

-0.06 0

<TS 120 E-50B C

106 31 15 VS4 0.2 0

<TS 121 E-50B C

106 31 21 VS4 0.81 0

<TS 122 E-50B C

106 31 15 03C 1.08 0

<TS 123 E-50B C

106 31 15 02C 1.02 0

<TS 124 E-50B C

45 32 23 VS4

-0.81 0

<TS 125 E-50B C

45 32 21 VS4 0.09 0

<TS 126 E-50B C

45 32 19 VS4 0.99 0

<TS 127 E-50B C

67 32 14 VS3 0.39 0

<TS 128 E-50B C

91 32 18 02C

-0.8 0

<TS 129 E-50B C

99 32 12 VS2

-0.82 0

<TS 130 E-50B C

99 32 14 02C 0.95 0

<TS 131 E-50B C

101 32 16 VS2 0.85 0

<TS 132 E-50B C

107 32 17 VS4

-0.93 0

<TS 133 E-50B C

46 33 26 VS4

-0.75 0

<TS 134 E-50B C

72 33 26 VS3

-0.87 0

<TS 135 E-50B C

72 33 27 VS3

-0.03 0

<TS 136 E-50B C

102 33 18 03C

-0.77 0

<TS 137 E-50B C

106 33 17 03C 0.26 0

<TS 138 E-50B C

108 33 27 08H 0.5 0

<TS 139 E-50B C

108 33 17 DBH

-1.6 0

<TS 140 E-50B C

45 34 16 VS4

-0.68 0

<TS 141 E-50B C

45 34 24 VS4

-0.06 0

<TS 36

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 142 E-50B C

45 34 15 VS4 0.71 0

<TS 143 E-50B C

49 34 14 VS4

-0.8 0

<TS 144 E-50B C

49 34 20 VS4 0.86 0

<TS 145 E-50B C

77 34 20 VS3 0.69 0

<TS 146 E-50B C

97 34 13 VS6

-0.77 0

<TS 147 E-50B C

105 34 16 03C

-0.72 0

<TS 148 E-50B C

105 34 17 02C 0.22 0

<TS 149 E-50B C

109 34 22 VS4

-0.84 0

<TS 150 E-50B C

109 34 22 04C 0.2 0

<TS 151 E-50B C

46 35 18 VS4

-0.6 0

<TS 152 E-50B C

76 35 18 DBH 1.58 0

<TS 153 E-50B C

102 35 18 03C 0.97 0

<TS 154 E-50B C

106 35 20 04H 0.79 0

<TS 155 E-50B C

106 35 15 02C 0.06 0

<TS 156 E-50B C

108 35 24 04H 0.67 0

<TS 157 E-50B C

108 35 16 04C

-0.77 0

<TS 158 E-50B C

108 35 16 04C 0.94 0

<TS 159 E-50B C

110 35 24 VS4 1

0

<TS 160 E-50B C

35 36 21 VS4 0.66 0

<TS 161 E-50B C

45 36 26 VS4 0.16 0

<TS 162 E-50B C

45 36 20 VS4 0.85 0

<TS 163 E-50B C

71 36 14 VS3

-0.24 0

<TS 164 E-50B C

71 36 20 VS3 0.77 0

<TS 165 E-50B C

71 36 20 VS4 0.73 0

<TS 166 E-50B C

71 36 16 VS5

-0.7 0

<TS 167 E-50B C

71 36 24 VS5 0.17 0

<TS 168 E-50B C

95 36 16 VS4

-1 0

<TS 169 E-50B C

95 36 16 VS4 0.97 0

<TS 170 E-50B C

107 36 22 VS2 0.91 0

<TS 171 E-50B C

109 36 17 02C

-0.77 0

<TS 172 E-50B C

111 36 21 VS4

-0.78 0

<TS 173 E-50B C

111 36 17 02C 0.19 0

<TS 174 E-50B C

111 36 12 02C 0.94 0

<TS 175 E-50B C

111 36 16 0iC 0.94 0

<TS 176 E-50B C

113 36 11 VS6

-0.81 0

<TS 177 E-50B C

113 36 13 VS6 0.7 0

<TS 178 E-50B C

113 36 15 02C 0.91 0

<TS 179 E-50B C

44 37 22 VS4

-0.25 0

<TS 180 E-50B C

44 37 25 VS4 0.13 0

<TS 181 E-50B C

44 37 16 VS4 0.69 0

<TS 182 E-50B C

46 37 15 VS4

-0.69 0

<TS 183 E-50B C

46 37 16 VS4 0.78 0

<TS 184 E-50B C

94 37 11 VS2

-0.9 0

<TS 185 E-50B C

106 37 25 VS2

-0.77 0

<TS 186 E-50B C

112 37 33 04C

-0.85 0

<TS 187 E-50B C

114 37 27 DBH 1.08 0

<TS 188 E-50B C

114 37 24 VS2

-0.71 0

<TS 189 E-50B C

114 37 28 VS2 0.05 0

<TS 37

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 190 E-50B C

114 37 18 VS4

-0.78 0

<TS 191 E-50B C

114 37 30 VS4 0.96 0

<TS 192 E-50B C

89 38 17 VS2

-0.8 0

<TS 193 E-50B C

105 38 15 03C 0.94 0

<TS 194 E-50B C

115 38 33 o1C 0.06 0

<TS 195 E-50B C

46 39 10 VS4

-0.57 0

<TS 196 E-50B C

46 39 14 VS4 0.15 0

<TS 197 E-50B C

46 39 19 VS4 0.57 0

<TS 198 E-50B C

66 39 15 VS5

-0.81 0

<TS 199 E-50B C

86 39 14 VS6

-0.39 0

<TS 200 E-50B C

106 39 25 VS2

-0.85 0

<TS 201 E-50B C

106 39 27 03C 0.97 0

<TS 202 E-50B C

114 39 22 VS2

-0.87 0

<TS 203 E-50B C

114 39 36 VS4 0.81 0

<TS 204 E-50B C

114 39 19 VS6

-0.6 0

<TS 205 E-50B C

107 40 19 VS2

-0.85 0

<TS 206 E-50B C

107 40 20 VS2 0.93 0

<TS 207 E-50B C

109 40 20 VS2

-0.79 0

<TS 208 E-50B C

109 40 18 VS2 0.82 0

<TS 209 E-50B C

117 40 21 04C 0

0

<TS 210 E-50B C

117 40 23 03C

-0.78 0

<TS 211 E-50B C

117 40 23 02C

-1.11 0

<TS 212 E-50B C

117 40 18 02C 0.06 0

<TS 213 E-50B C

117 40 18 02C 0.81 0

<TS 214 E-50B C

42 41 20 VS4

-0.82 0

<TS 215 E-50B C

42 41 27 VS4 0.19 0

<TS 216 E-50B C

42 41 33 VS4 0.88 0

<TS 217 E-50B C

44 41 20 02C

-0.06 0

<TS 218 E-50B C

60 41 26 02H

-0.08 0

<TS 219 E-50B C

66 41 18 VS3

-0.69 0

<TS 220 E-50B C

68 41 22 04H 0.75 0

<TS 221 E-50B C

72 41 26 06C 0.86 0

<TS 222 E-50B C

82 41 24 VS3 0.86 0

<TS 223 E-50B C

98 41 15 VS2

-0.87 0

<TS 224 E-50B C

98 41 22 VS2 0.89 0

<TS 225 E-50B C

98 41 26 VS4 0.79 0

<TS 226 E-50B C

98 41 12 VS6 0.86 0

<TS 227 E-50B C

102 41 7

06H

-0.81 0

<TS 228 E-50B C

102 41 16 06H 0.7 0

<TS 229 E-50B C

35 42 17 05H 0.9 0

<TS 230 E-50B C

45 42 21 VS4

-0.6 0

<TS 231 E-50B C

45 42 16 VS4 0.87 0

<TS 232 E-50B C

53 42 11 VS5

-0.44 0

<TS 233 E-50B C

61 42 16 VS3 0.73 0

<TS 234 E-50B C

63 42 15 VS3 0.91 0

<TS 235 E-50B C

97 42 15 VS2

-0.8 0

<TS 236 E-50B C

107 42 26 VS2

-0.79 0

<TS 237 E-50B C

107 42 29 VS2 0.9 0

<TS 38

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 238 E-50B C

107 42 18 VS4 0.21 0

<TS 239 E-50B C

107 42 29 VS4 0.95 0

<TS 240 E-50B C

107 42 18 VS6

-0.8 0

<TS 241 E-50B C

107 42 12 VS6 0.8 0

<TS 242 E-50B C

113 42 14 VS4 0.97 0

<TS 243 E-50B C

119 42 20 VS7

-0.83 0

<TS 244 E-50B C

119 42 19 04C

-0.06 0

<TS 245 E-50B C

119 42 15 03C 1.03 0

<TS 246 E-50B C

46 43 25 01H 0.84 0

<TS 247 E-50B C

74 43 11 VS3

-0.51 0

<TS 248 E-50B C

74 43 17 VS4

-0.36 0

<TS 249 E-50B C

82 43 9

VS3

-0.3 0

<TS 250 E-50B C

82 43 19 VS3 0.22 0

<TS 251 E-50B C

82 43 17 VS3 0.91 0

<TS 252 E-50B C

82 43 20 VS5

-0.94 0

<TS 253 E-50B C

82 43 21 VS5 0

0

<TS 254 E-50B C

108 43 16 VS4

-0.91 0

<TS 255 E-50B C

112 43 21 VS2

-0.82 0

<TS 256 E-50B C

112 43 19 VS2 0.93 0

<TS 257 E-50B C

112 43 17 VS4

-0.88 0

<TS 258 E-50B C

114 43 10 07H 0.97 0

<TS 259 E-50B C

116 43 14 VS4 1

0

<TS 260 E-50B C

118 43 18 VS4 0.99 0

<TS 261 E-50B C

118 43 20 VS6

-0.14 0

<TS 262 E-50B C

120 43 21 0iC

-0.8 0

<TS 263 E-50B C

119 44 18 02H 0.69 0

<TS 264 E-50B C

121 44 20 01H 0.86 0

<TS 265 E-50B C

30 45 18 VS4 0.88 0

<TS 266 E-50B C

36 45 18 VS4

-0.67 0

<TS 267 E-50B C

38 45 16 02C 0.08 0

<TS 268 E-50B C

44 45 22 VS4 0.78 0

<TS 269 E-50B C

44 45 17 04C 0.85 0

<TS 270 E-50B C

44 45 14 03C 0.75 0

<TS 271 E-50B C

74 45 16 VS5

-0.89 0

<TS 272 E-50B C

80 45 23 06H 0

0

<TS 273 E-50B C

120 45 16 02C 0.92 0

<TS 274 E-50B C

9 46 20 DBH 0.37 0

<TS 275 E-50B C

47 46 18 VS4

-0.51 0

<TS 276 E-50B C

47 46 15 VS4 0.11 0

<TS 277 E-50B C

49 46 12 VS4

-0.6 0

<TS 278 E-50B C

67 46 12 DBC 2

0

<TS 279 E-50B C

97 46 13 VS4 0.86 0

<TS 280 E-50B C

107 46 24 VS6

-0.87 0

<TS 281 E-50B C

44 47 24 VS4

-0.7 0

<TS 282 E-50B C

58 47 15 VS5

-0.91 0

<TS 283 E-50B C

68 47 12 VS4 0.96 0

<TS 284 E-50B C

80 47 19 VS3

-0.75 0

<TS 285 E-50B C

80 47 21 VS5 0.89 0

<TS 39

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 286 E-50B C

108 47 16 VS2

-0.52 0

<TS 287 E-50B C

112 47 22 VS2

-0.81 0

<TS 288 E-50B C

114 47 12 VS4

-0.75 0

<TS 289 E-50B C

114 47 11 VS4 0.86 0

<TS 290 E-50B C

116 47 17 VS4 0.97 0

<TS 291 E-50B C

120 47 19 03C 0.96 0

<TS 292 E-50B C

43 48 23 05C 0.92 0

<TS 293 E-50B C

45 48 18 VS4

-0.91 0

<TS 294 E-50B C

45 48 21 VS4 0.27 0

<TS 295 E-50B C

45 48 23 VS4 0.63 0

<TS 296 E-50B C

47 48 18 06C 0.81 0

<TS 297 E-50B C

59 48 18 06H 0.81 0

<TS 298 E-50B C

59 48 24 03C 0.83 0

<TS 299 E-50B C

77 48 18 VS4 0.92 0

<TS 300 E-50B C

103 48 17 VS4

-1.05 0

<TS 301 E-50B C

113 48 28 VS2

-0.87 0

<TS 302 E-50B C

113 48 34 VS4

-0.75 0

<TS 303 E-50B C

125 48 19 VS4 0.85 0

<TS 304 E-50B C

125 48 18 VS6 0.95 0

<TS 305 E-50B C

38 49 19 VS4 0.72 0

<TS 306 E-50B C

72 49 24 03C 1.05 0

<TS 307 E-50B C

92 49 18 05H 0.89 0

<TS 308 E-50B C

98 49 20 VS2

-0.69 0

<TS 309 E-50B C

120 49 17 VS2 0.11 0

<TS 310 E-50B C

124 49 19 02C

-0.83 0

<TS 311 E-50B C

111 50 17 VS2 0.9 0

<TS 312 E-50B C

36 51 11 VS4

-0.79 0

<TS 313 E-50B C

36 51 15 VS4 0.98 0

<TS 314 E-50B C

38 51 16 VS4

-0.76 0

<TS 315 E-50B C

42 51 33 VS4

-0.76 0

<TS 316 E-50B C

42 51 20 VS4 0.98 0

<TS 317 E-50B C

64 51 19 VS5 0.09 0

<TS 318 E-50B C

64 51 16 VS5 0.88 0

<TS 319 E-50B C

88 51 21 VS4

-0.56 0

<TS 320 E-50B C

102 51 16 07C 0.97 0

<TS 321 E-50B C

106 51 19 07C 0.9 0

<TS 322 E-50B C

108 51 24 VS2

-0.52 0

<TS 323 E-50B C

108 51 16 VS2 0.8 0

<TS 324 E-50B C

124 51 17 VS4 0.55 0

<TS 325 E-50B C

69 52 19 VS3 0

0

<TS 326 E-50B C

69 52 22 VS4

-0.8 0

<TS 327 E-50B C

69 52 14 VS4 0.13 0

<TS 328 E-50B C

69 52 17 VS5

-1.03 0

<TS 329 E-50B C

69 52 16 VS5 1.03 0

<TS 330 E-50B C

71 52 17 03C 0.88 0

<TS 331 E-50B C

81 52 29 VS3 0.73 0

<TS 332 E-50B C

109 52 20 VS2

-0.9 0

<TS 333 E-50B C

109 52 31 VS2 0.85 0

<TS 40

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 334 E-50B C

109 52 17 VS6 1.07 0

<TS 335 E-50B C

123 52 19 02C 1.04 0

<TS 336 E-50B C

30 53 17 02C 0.72 0

<TS 337 E-50B C

112 53 19 VS2

-0.84 0

<TS 338 E-50B C

112 53 18 VS2 0.89 0

<TS 339 E-50B C

41 54 15 VS4

-0.73 0

<TS 340 E-50B C

41 54 22 VS4 0.88 0

<TS 341 E-50B C

85 54 6

VS4

-0.52 0

<TS 342 E-50B C

91 54 16 02C 1.05 0

<TS 343 E-50B C

105 54 22 VS6

-0.85 0

<TS 344 E-50B C

127 54 16 01H

-1.09 0

<TS 345 E-50B C

36 55 13 VS4 0.94

.0

<TS 346 E-50B C

72 55 18 VS3

-0.82 0

<TS 347 E-50B C

98 55 27 VS2

-0.49 0

<TS 348 E-50B C

110 55 29 VS2

-0.86 0

<TS 349 E-50B C

116 55 11 VS2

-0.88 0

<TS 350 E-50B C

116 55 18 VS4 0.91 0

<TS 351 E-50B C

128 55 22 0iC 0

0

<TS 352 E-50B C

130 55 14 02C 0.99 0

<TS 353 E-50B C

45 56 15 03H 0.84 0

<TS 354 E-50B C

47 56 15 VS4

-0.83 0

<TS 355 E-50B C

47 56 29 VS4 0.92 0

<TS 356 E-50B C

111 56 14 VS4

-0.69 0

<TS 357 E-50B C

111 56 10 VS6

-0.72 0

<TS 358 E-50B C

129 56 19 01H 0.75 0

<TS 359 E-50B C

42 57 12 VS4 0.23 0

<TS 360 E-50B C

42 57 27 VS4 0.82 0

<TS 361 E-50B C

44 57 11 VS4

-0.61 0

<TS 362 E-50B C

44 57 11 VS4 0.15 0

<TS 363 E-50B C

78 57 14 03C 0.96 0

<TS 364 E-50B C

47 58 8

VS4

-0.95 0

<TS 365 E-50B C

47 58 16 VS4 0.88 0

<TS 366 E-50B C

51 58 18 01H 1.02 0

<TS 367 E-50B C

51 58 19 03H 0.8 0

<TS 368 E-50B C

67 58 9

03C 0.19 0

<TS 369 E-50B C

67 58 14 03C 0.89 0

<TS 370 E-50B C

105 58 18 VS2

-0.91 0

<TS 371 E-50B C

105 58 16 VS6 0.71 0

<TS 372 E-50B C

131 58 28 0iC 0.88 0

<TS 373 E-50B C

44 59 20 VS4

-0.06 0

<TS 374 E-50B C

44 59 13 VS4 0.75 0

<TS 375 E-50B C

46 59 20 03C 0.88 0

<TS 376 E-50B C

48 59 12 VS4 0.8 0

<TS 377 E-50B C

76 59 15 VS3

-0.84 0

<TS 378 E-50B C

98 59 16 VS2

-0.84 0

<TS 379 E-50B C

98 59 14 VS2 0.92 0

<TS 380 E-50B C

108 59 19 VS2

-0.92 0

<TS 381 E-50B C

108 59 18 VS2 0.87 0

<TS 41

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 382 E-50B C

112 59 18 VS2

-0.32 0

<TS 383 E-50B C

112 59 19 VS2 0.09 0

<TS 384 E-50B C

112 59 17 VS2 0.35 0

<TS 385 E-50B C

89 60 15 04C

-0.85 0

<TS 386 E-50B C

97 60 18 VS2 0.93 0

<TS 387 E-50B C

78 61 21 VS3

-0.8 0

<TS 388 E-50B C

120 61 19 08C 0.73 0

<TS 389 E-50B C

132 61 27 02H

-0.93 0

<TS 390 E-50B C

13 62 13 DBC

-1.77 0

<TS 391 E-50B C

13 62 11 05C

-0.83 0

<TS 392 E-50B C

57 62 11 DBC 0.89 0

<TS 393 E-50B C

65 62 18 04H

-1.13 0

<TS 394 E-50B C

101 62 16 VS2

-0.87 0

<TS 395 E-50B C

103 62 17 03C 0.94 0

<TS 396 E-50B C

109 62 17 07C 0.91 0

<TS 397 E-50B C

44 63 11 VS4

-0.91 0

<TS 398 E-50B C

44 63 19 VS4 0.92 0

<TS 399 E-50B C

66 63 19 VS3

-0.81 0

<TS 400 E-50B C

66 63 19 VS3

-0.39 0

<TS 401 E-50B C

106 63 23 VS2 0.16 0

<TS 402 E-50B C

134 63 16 DBH

-1.79 0

<TS 403 E-50B C

21 64 14 DBC

-1.64 0

<TS 404 E-50B C

25 64 16 DBH

-1.73 0

<TS 405 E-50B C

91 64 21 03C

-0.9 0

<TS 406 E-50B C

103 64 27 VS2 0.94 0

<TS 407 E-50B C

123 64 17 VS4 0.93 0

<TS 408 E-50B C

131 64 28 VS7 0.93 0

<TS 409 E-50B C

44 65 16 VS4

-0.21 0

<TS 410 E-50B C

44 65 16 VS4 0.03 0

<TS 411 E-50B C

44 65 21 VS4 0.72 0

<TS 412 E-50B C

48 65 26 VS4

-0.75 0

<TS 413 E-50B C

130 65 20 VS4 0.99 0

<TS 414 E-50B C

130 65 28 VS7 1.01 0

<TS 415 E-50B C

134 65 24 02H 0.73 0

<TS 416 E-50B C

59 66 17 02H

-1 0

<TS 417 E-50B C

97 66 11 VS2

-0.92 0

<TS 418 E-50B C

101 66 11 VS4

-0.75 0

<TS 419 E-50B C

101 66 14 VS4 1.04 0

<TS 420 E-50B C

111 66 19 07H 0.95 0

<TS 421 E-50B C

48 67 16 VS4

-0.03 0

<TS 422 E-50B C

88 67 15 VS2

-0.8 0

<TS 423 E-50B C

88 67 16 VS2 0.73 0

<TS 424 E-50B C

92 67 17 VS6

-0.76 0

<TS 425 E-50B C

92 67 13 VS6 0.68 0

<TS 426 E-50B C

61 68 15 02H

-0.8 0

<TS 427 E-50B C

117 68 21 05H 0.96 0

<TS 428 E-50B C

135 68 19 VS7 1.06 0

<TS 429 E-50B C

46 69 16 DBH

-1.6 0

<TS 42

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 430 E-50B C

90 69 14 07H

-0.91 0

<TS 431 E-50B C

90 69 13 07H 0.77 0

<TS 432 E-50B C

92 69 16 04C 0.92 0

<TS 433 E-50B C

108 69 17 05H 0.87 0

<TS 434 E-50B C

134 69 17 04H 0.11 0

<TS 435 E-50B C

134 69 22 04H 0.93 0

<TS 436 E-50B C

134 69 29 VS7 1.02 0

<TS 437 E-50B C

47 70 16 VS4

-0.68 0

<TS 438 E-50B C

63 70 15 04H 0.79 0

<TS 439 E-50B C

113 70 19 07C 0

0

<TS 440 E-50B C

113 70 19 07C 0.78 0

<TS 441 E-50B C

60 71 14 VS5 0.55 0

<TS 442 E-50B C

98 71 13 VS2 0.95 0

<TS 443 E-50B C

106 71 15 VS2

-0.38 0

<TS 444 E-50B C

59 72 18 03H 0.94 0

<TS 445 E-50B C

69 72 17 06C

-0.93 0

<TS 446 E-50B C

123 72 21 VS4

-0.74 0

<TS 447 E-50B C

80 73 19 03H

-0.8 0

<TS 448 E-50B C

92 73 15 VS2 0.79 0

<TS 449 E-50B C

118 73 20 VS6

-0.99 0

<TS 450 E-50B C

128 73 27 VS1 0.15 0

<TS 451 E-50B C

128 73 19 VS4 0.8 0

<TS 452 E-50B C

49 74 15 DBH

-1.68 0

<TS 453 E-50B C

106 75 15 VS2 0.9 0

<TS 454 E-50B C

69 76 14 VS5 0.79 0

<TS 455 E-50B C

105 76 18 VS2 0.9 0

<TS 456 E-50B C

135 76 22 VS7

-0.83 0

<TS 457 E-50B C

135 76 24 08C

-1.16 0

<TS 458 E-50B C

135 76 22 08C 0.83 0

<TS 459 E-50B C

72 77 20 02H 0.82 0

<TS 460 E-50B C

84 77 16 05C

-0.9 0

<TS 461 E-50B C

106 77 24 VS2 0.93 0

<TS 462 E-50B C

116 77 21 VS2 0.78 0

<TS 463 E-50B C

130 77 23 VS2 0.97 0

<TS 464 E-50B C

130 77 20 VS4 0.67 0

<TS 465 E-50B C

136 77 21 03H 1.01 0

<TS 466 E-50B C

138 77 19 VS4 1.12 0

<TS 467 E-50B C

85 78 16 05H 0.88 0

<TS 468 E-50B C

105 78 13 VS2 0.89 0

<TS 469 E-50B C

105 78 21 VS6

-0.93 0

<TS 470 E-50B C

105 78 22 VS6 0.96 0

<TS 471 E-50B C

107 78 11 VS2

-1.03 0

<TS 472 E-50B C

107 78 14 VS2 0.9 0

<TS 473 E-50B C

109 78 15 04C

-0.87 0

<TS 474 E-50B C

110 79 19 VS2

-0.05 0

<TS 475 E-50B C

112 79 20 VS2 0.64 0

<TS 476 E-50B C

138 79 25 VS1

-0.67 0

<TS 477 E-50B C

138 79 9

VS1 0.84 0

<TS 43

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 478 E-50B C

138 79 21 VS2 0.65 0

<TS 479 E-50B C

138 79 18 VS4 0.92 0

<TS 480 E-50B C

138 79 17 VS6

-0.91 0

<TS 481 E-50B C

138 79 16 VS6 0.91 0

<TS 482 E-50B C

53 80 23 03C 0.71 0

<TS 483 E-50B C

105 80 25 VS2

-0.23 0

<TS 484 E-50B C

125 80 14 VS4 0.93 0

<TS 485 E-50B C

137 80 16 08H 0.73 0

<TS 486 E-50B C

78 81 19 03H 0.76 0

<TS 487 E-50B C

84 81 20 02C 0.83 0

<TS 488 E-50B C

98 81 19 VS2 0.93 0

<TS 489 E-50B C

98 81 24 VS4

-0.75 0

<TS 490 E-50B C

116 81 23 VS7

-1.02 0

<TS 491 E-50B C

116 81 19 07C

-1.04 0

<TS 492 E-50B C

116 81 17 07C

-0.27 0

<TS 493 E-50B C

132 81 16 05H 0.92 0

<TS 494 E-50B C

138 81 18 VS4

-0.81 0

<TS 495 E-50B C

59 82 11 VS4 0.82 0

<TS 496 E-50B C

63 82 23 VS4 1.05 0

<TS 497 E-50B C

63 82 21 VS5 1.05 0

<TS 498 E-50B C

85 82 13 VS6

-0.62 0

<TS 499 E-50B C

87 82 16 03H 0.76 0

<TS 500 E-50B C

99 82 11 VS2

-0.74 0

<TS 501 E-50B C

103 82 16 VS2 0.91 0

<TS 502 E-50B C

107 82 30 VS2

-0.6 0

<TS 503 E-50B C

107 82 25 VS2 0.96 0

<TS 504 E-50B C

125 82 14 VS1

-0.65 0

<TS 505 E-50B C

135 82 22 VS7

-0.74 0

<TS 506 E-50B C

135 82 27 VS7 0.85 0

<TS 507 E-50B C

92 83 18 05H 0.94 0

<TS 508 E-50B C

79 84 20 VS4

-0.47 0

<TS 509 E-50B C

89 84 21 03H 1.01 0

<TS 510 E-50B C

91 84 19 VS6 0.03 0

<TS 511 E-50B C

97 84 20 07C

-0.92 0

<TS 512 E-50B C

97 84 16 07C

-0.18 0

<TS 513 E-50B C

109 84 17 04H

-0.2 0

<TS 514 E-50B C

113 84 18 02H

-0.8 0

<TS 515 E-50B C

113 84 17 04H

-0.87 0

<TS 516 E-50B C

115 84 18 03H

-0.78 0

<TS 517 E-50B C

129 84 19 06H 0.9 0

<TS 518 E-50B C

56 85 25 03C 0.98 0

<TS 519 E-50B C

56 85 15 02C

-0.8 0

<TS 520 E-50B C

102 85 28 VS6

-0.83 0

<TS 521 E-50B C

106 85 13 02C 0.88 0

<TS 522 E-50B C

112 85 13 VS6 0.79 0

<TS 523 E-50B C

124 85 17 VS4

-0.62 0

<TS 524 E-50B C

138 85 22 DBH 1.46 0

<TS 525 E-50B C

63 86 12 02C

-0.83 0

<TS 44

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 526 E-50B C

79 86 16 03H 0.92 0

<TS 527 E-50B C

118 87 15 VS2 0.96 0

<TS 528 E-50B C

126 87 31 VS2 0.94 0

<TS 529 E-50B C

126 87 31 VS4

-0.55 0

<TS 530 E-50B C

126 87 17 VS4 1.16 0

<TS 531 E-50B C

126 87 18 VS6 0.67 0

<TS 532 E-50B C

136 87 14 08C

-1.04 0

<TS 533 E-50B C

138 87 18 VS1

-0.79 0

<TS 534 E-50B C

138 87 19 VS4

-0.68 0

<TS 535 E-50B C

91 88 18 04H

-0.84 0

<TS 536 E-50B C

119 88 22 08C 0.78 0

<TS 537 E-50B C

118 89 22 VS2 0.92 0

<TS 538 E-50B C

118 89 17 VS4 0.68 0

<TS 539 E-50B C

136 89 23 VS2 0.61 0

<TS 540 E-50B C

138 89 14 VS4

-0.57 0

<TS 541 E-50B C

138 89 28 VS7 0.95 0

<TS 542 E-50B C

57 90 13 03C

-0.92 0

<TS 543 E-50B C

57 90 18 03C 0.91 0

<TS 544 E-50B C

101 90 9

VS6

-0.81 0

<TS 545 E-50B C

105 90 19 VS2 0.95 0

<TS 546 E-50B C

105 90 21 VS4 0.9 0

<TS 547 E-50B C

105 90 17 07C 0.73 0

<TS 548 E-50B C

135 90 29 VS7 0.65 0

<TS 549 E-50B C

137 90 20 DBH 1.51 0

<TS 550 E-50B C

137 90 14 VS4 0.87 0

<TS 551 E-50B C

137 90 16 VS6

-0.74 0

<TS 552 E-50B C

137 90 19 VS7

-0.8 0

<TS 553 E-50B C

137 90 17 VS7 0.97 0

<TS 554 E-50B C

137 90 11 DBC 1.93 0

<TS 555 E-50B C

116 91 15 VS2

-0.74 0

<TS 556 E-50B C

130 91 24 DBC 1.66 0

<TS 557 E-50B C

136 91 17 DBC 1.98 0

<TS 558 E-50B C

127 92 21 08C

-0.11 0

<TS 559 E-50B C

135 92 39 VS7

-0.76 0

<TS 560 E-50B C

135 92 36 08C 0.9 0

<TS 561 E-50B C

135 92 20 07C 0.76 0

<TS 562 E-50B C

137 92 19 VS6

-0.74 0

<TS 563 E-50B C

137 92 18 VS6 1.12 0

<TS 564 E-50B C

137 92 20 VS7

-0.72 0

<TS 565 E-50B C

84 93 15 02C

-1 0

<TS 566 E-50B C

94 93 10 04C

-1.05 0

<TS 567 E-50B C

94 93 17 04C

-0.12 0

<TS 568 E-50B C

94 93 13 03C

-0.7 0

<TS 569 E-50B C

124 93 11 VS1 0.7 0

<TS 570 E-50B C

124 93 18 VS2

-0.71 0

<TS 571 E-50B C

124 93 26 VS2 0.08 0

<TS 572 E-50B C

124 93 15 VS2 0.87 0

<TS 573 E-50B C

124 93 13 VS4

-0.84 0

<TS 45

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 574 E-50B C

103 94 19 VS2

-0.75 0

<TS 575 E-50B C

103 94 9

VS2 0.99 0

<TS 576 E-50B C

125 94 18 VS2

-0.62 0

<TS 577 E-50B C

135 94 28 DBC 1.68 0

<TS 578 E-50B C

80 95 24 04H 0.87 0

<TS 579 E-50B C

88 95 20 03C 0.98 0

<TS 580 E-50B C

96 95 17 VS2

-0.81 0

<TS 581 E-50B C

96 95 17 VS2 1

0

<TS 582 E-50B C

102 95 7

VS6

-0.91 0

<TS 583 E-50B C

104 95 17 VS2

-0.66 0

<TS 584 E-50B C

104 95 13 VS2 0.06 0

<TS 585 E-50B C

104 95 16 VS2 0.8 0

<TS 586 E-50B C

124 95 15 VS4

-0.81 0

<TS 587 E-50B C

124 95 19 VS4 0.95 0

<TS 588 E-50B C

126 95 28 VS4

-0.66 0

<TS 589 E-50B C

126 95 20 VS6 0.99 0

<TS 590 E-50B C

134 95 23 DBC 1.47 0

<TS 591 E-50B C

136 95 17 03C 0.95 0

<TS 592 E-50B C

47 96 13 VS4

-0.34 0

<TS 593 E-50B C

47 96 19 VS4 0.67 0

<TS 594 E-50B C

105 96 16 04C

-0.93 0

<TS 595 E-50B C

107 96 21 VS2 0.97 0

<TS 596 E-50B C

107 96 14 VS4 0.26 0

<TS 597 E-50B C

131 96 21 04C 0.92 0

<TS 598 E-50B C

56 97 15 04C 0.77 0

<TS 599 E-50B C

74 97 17 VS4 1.19 0

<TS 600 E-50B C

92 97 7

04C

-0.09 0

<TS 601 E-50B C

92 97 13 04C 0.91 0

<TS 602 E-50B C

110 97 20 08H 1.18 0

<TS 603 E-50B C

132 97 17 VS2

-0.23 0

<TS 604 E-50B C

136 97 27 VS7

-0.74 0

<TS 605 E-50B C

136 97 14 VS7 1.03 0

<TS 606 E-50B C

136 97 15 08C

-1.09 0

<TS 607 E-50B C

136 97 11 08C 0

0

<TS 608 E-50B C

136 97 16 07C 0.67 0

<TS 609 E-50B C

136 97 19 03C 0.78 0

<TS 610 E-50B C

47 98 22 VS4 0.9 0

<TS 611 E-50B C

131 98 24 VS6 1.12 0

<TS 612 E-50B C

131 98 30 VS7 0.86 0

<TS 613 E-50B C

70 99 20 VS3 0.76 0

<TS 614 E-50B C

102 99 10 07C 0.29 0

<TS 615 E-50B C

102 99 18 07C 0.82 0

<TS 616 E-50B C

126 99 19 08C 0.85 0

<TS 617 E-50B C

126 99 19 07C 0.97 0

<TS 618 E-50B C

134 99 17 VS6

-0.74 0

<TS 619 E-50B C

134 99 25 VS6 1.14 0

<TS 620 E-50B C

133 100 18 VS7 0.2 0

<TS 621 E-50B C

74 101 15 VS5

-0.93 0

<TS 46

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 622 E-50B C

106 101 18 VS2

-0.77 0

<TS 623 E-50B C

128 101 22 05C 0.76 0

<TS 624 E-50B C

132 101 13 06C

-0.2 0

<TS 625 E-50B C

132 101 17 06C 0.84 0

<TS 626 E-50B C

134 101 23 VS7 1.05 0

<TS 627 E-50B C

39 102 17 VS4

-0.92 0

<TS 628 E-50B C

61 102 16 05C

-0.2 0

<TS 629 E-50B C

63 102 20 04C

-0.94 0

<TS 630 E-50B C

127 102 16 07C

-0.11 0

<TS 631 E-50B C

129 102 19 08C

-0.98 0

<TS 632 E-50B C

131 102 22 06C

-1.04 0

<TS 633 E-50B C

131 102 19 05C 0.81 0

<TS 634 E-50B C

133 102 18 07C

-0.96 0

<TS 635 E-50B C

44 103 29 VS4 1

0

<TS 636 E-50B C

46 103 11 04C 0.82 0

<TS 637 E-50B C

92 103 19 DBC 0.78 0

<TS 638 E-50B C

116 103 11 VS2

-0.79 0

<TS 639 E-50B C

126 103 20 VS4 0.88 0

<TS 640 E-50B C

67 104 17 06C

-0.06 0

<TS 641 E-50B C

77 104 21 05H 0.84 0

<TS 642 E-50B C

77 104 22 05C 0.94 0

<TS 643 E-50B C

83 104 27 DBC 1.57 0

<TS 644 E-50B C

101 104 22 DBH 1.51 0

<TS 645 E-50B C

109 104 28 VS2 0.89 0

<TS 646 E-50B C

119 104 17 VS1

-0.72 0

<TS 647 E-50B C

121 104 18 05H 0.67 0

<TS 648 E-50B C

125 104 20 07H 0.87 0

<TS 649 E-50B C

125 104 20 07C

-0.2 0

<TS 650 E-50B C

131 104 28 VS7 0.88 0

<TS 651 E-50B C

133 104 20 VS7 0.91 0

<TS 652 E-50B C

118 105 15 VS4

-0.6 0

<TS 653 E-50B C

120 105 21 VS2

-0.77 0

<TS 654 E-50B C

95 106 22 04C

-0.94 0

<TS 655 E-50B C

127 106 23 07C

-0.34 0

<TS 656 E-50B C

129 106 9

08C

-0.2 0

<TS 657 E-50B C

129 106 18 08C 0.96 0

<TS 658 E-50B C

133 106 37 VS6 0

0

<TS 659 E-50B C

133 106 26 VS6 0.96 0

<TS 660 E-50B C

133 106 24 VS7

-0.85 0

<TS 661 E-50B C

38 107 20 02C 0.92 0

<TS 662 E-50B C

44 107 15 VS4

-0.86 0

<TS 663 E-50B C

44 107 20 VS4 1.12 0

<TS 664 E-50B C

48 107 12 04C 0.87 0

<TS 665 E-50B C

48 107 12 02C 0.74 0

<TS 666 E-50B C

132 107 23 02C

-0.95 0

<TS 667 E-50B C

39 108 15 DBH

-1.71 0

<TS 668 E-50B C

47 108 22 06H 0.73 0

<TS 669 E-50B C

47 108 19 VS4

-0.69 0

<TS 47

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 670 E-50B C

47 108 21 VS4 0.91 0

<TS 671 E-50B C

61 108 14 VS3 0.75 0

<TS 672 E-50B C

103 108 19 VS6

-0.73 0

<TS 673 E-50B C

113 108 14 VS2 0.71 0

<TS 674 E-50B C

34 109 16 03C 0.8 0

<TS 675 E-50B C

38 109 16 VS4

-0.33 0

<TS 676 E-50B C

68 109 17 02H 0.87 0

<TS 677 E-50B C

70 109 16 VS4

-1.01 0

<TS 678 E-50B C

78 109 14 02H

-0.91 0

<TS 679 E-50B C

78 109 9

03H 0.08 0

<TS 680 E-50B C

78 109 17 03H 0.89 0

<TS 681 E-50B C

100 109 26 VS2

-0.48 0

<TS 682 E-50B C

102 109 10 04C

-0.84 0

<TS 683 E-50B C

126 109 18 04H 0.77 0

<TS 684 E-50B C

130 109 16 04H 0.78 0

<TS 685 E-50B C

63 110 19 03H

-0.11 0

<TS 686 E-50B C

65 110 19 03H 0.89 0

<TS 687 E-50B C

69 110 17 03C 0.78 0

<TS 688 E-50B C

71 110 18 04H

-0.86 0

<TS 689 E-50B C

79 110 28 VS5 0.81 0

<TS 690 E-50B C

85 110 19 04C 0.77 0

<TS 691 E-50B C

113 110 14 04C 0.96 0

<TS 692 E-50B C

30 111 17 03C

-0.91 0

<TS 693 E-50B C

36 111 19 VS4 0.85 0

<TS 694 E-50B C

116 111 23 04C

-0.83 0

<TS 695 E-50B C

109 112 20 07H 0.74 0

<TS 696 E-50B C

111 112 13 VS2 0.94 0

<TS 697 E-50B C

117 112 18 04H 0.81 0

<TS 698 E-50B C

119 112 20 04C 0.79 0

<TS 699 E-50B C

125 112 20 02C 0.81 0

<TS 700 E-50B C

127 112 20 02C 0.83 0

<TS 701 E-50B C

36 113 21 03C 0.78 0

<TS 702 E-50B C

68 113 17 03H 0.86 0

<TS 703 E-50B C

68 113 17 04H

-0.78 0

<TS 704 E-50B C

68 113 22 04H 0.76 0

<TS 705 E-50B C

72 113 17 02H

-0.93 0

<TS 706 E-50B C

72 113 9

02H 0.87 0

<TS 707 E-50B C

72 113 15 04C 0.81 0

<TS 708 E-50B C

106 113 16 VS2 0

0

<TS 709 E-50B C

108 113 22 VS4

-0.82 0

<TS 710 E-50B C

108 113 20 VS4 0.9 0

<TS 711 E-50B C

120 113 24 VS2

-0.76 0

<TS 712 E-50B C

120 113 20 VS2 0.91 0

<TS 713 E-50B C

128 113 21 02C

-0.96 0

<TS 714 E-50B C

55 114 13 03C 0.2 0

<TS 715 E-50B C

55 114 13 03C 0.96 0

<TS 716 E-50B C

61 114 13 04C 0.88 0

<TS 717 E-50B C

81 114 15 VS5

-0.17 0

<TS 48

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 718 E-50B C

109 114 23 VS2

-0.32 0

<TS 719 E-50B C

109 114 17 VS2 0.05 0

<TS 720 E-50B C

109 114 36 VS4

-0.62 0

<TS 721 E-50B C

109 114 32 VS6

-0.54 0

<TS 722 E-50B C

109 114 6

VS6 0.72 0

<TS 723 E-50B C

121 114 18 VS4

-0.85 0

<TS 724 E-50B C

125 114 18 03C 0.81 0

<TS 725 E-50B C

127 114 18 02C 0.96 0

<TS 726 E-50B C

22 115 16 04C

-0.77 0

<TS 727 E-50B C

80 115 16 VS3 0.74 0

<TS 728 E-50B C

80 115 18 VS4

-0.96 0

<TS 729 E-50B C

108 115 14 07C 0.84 0

<TS 730 E-50B C

116 115 22 VS4 0.96 0

<TS 731 E-50B C

120 115 25 03C 0.86 0

<TS 732 E-50B C

126 115 12 02C 0.09 0

<TS 733 E-50B C

126 115 24 02C 0.74 0

<TS 734 E-50B C

39 116 19 VS4

-0.85 0

<TS 735 E-50B C

39 116 32 VS4 0.74 0

<TS 736 E-50B C

107 116 23 VS2

-0.86 0

<TS 737 E-50B C

107 116 17 VS2 0.13 0

<TS 738 E-50B C

107 116 25 VS2 0.76 0

<TS 739 E-50B C

123 116 34 VS6

-0.87 0

<TS 740 E-50B C

125 116 19 02H 0.9 0

<TS 741 E-50B C

125 116 18 VS4

-0.77 0

<TS 742 E-50B C

40 117 17 03C 0.86 0

<TS 743 E-50B C

74 117 13 VS3

-0.98 0

<TS 744 E-50B C

116 117 14 03C

-0.87 0

<TS 745 E-50B C

116 117 19 03C

-0.12 0

<TS 746 E-50B C

118 117 14 04C

-0.06 0

<TS 747 E-50B C

124 117 17 VS7

-0.14 0

<TS 748 E-50B C

124 117 20 04C 0.8 0

<TS 749 E-50B C

45 118 18 06H 0.24 0

<TS 750 E-50B C

123 118 28 VS6

-0.81 0

<TS 751 E-50B C

123 118 16 VS7

-0.92 0

<TS 752 E-50B C

39 120 22 VS4 1.04 0

<TS 753 E-50B C

41 120 8

05C 0.77 0

<TS 754 E-50B C

45 120 14 VS4

-0.46 0

<TS 755 E-50B C

57 120 17 05C 0.58 0

<TS 756 E-50B C

69 120 11 03C 0.11 0

<TS 757 E-50B C

69 120 15 03C 0.86 0

<TS 758 E-50B C

107 120 13 DBC 1.68 0

<TS 759 E-50B C

40 121 16 VS4

-0.86 0

<TS 760 E-50B C

40 121 25 VS4 0.9 0

<TS 761 E-50B C

76 121 15 04C 0.78 0

<TS 762 E-50B C

102 121 11 VS2

-0.78 0

<TS 763 E-50B C

116 121 11 VS2

-0.59 0

<TS 764 E-50B C

37 122 30 VS4

-0.88 0

<TS 765 E-50B C

41 122 19 VS4

-0.93 0

<TS 49

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 766 E-50B C

41 122 19 VS4 0.66 0

<TS 767 E-50B C

45 122 25 VS4

-0.92 0

<TS 768 E-50B C

45 122 30 VS4 0.8 0

<TS 769 E-50B C

49 122 12 VS4

-0.48 0

<TS 770 E-50B C

49 122 17 04C 0.91 0

<TS 771 E-50B C

59 122 17 03C

-0.09 0

<TS 772 E-50B C

65 122 16 02C 0.74 0

<TS 773 E-50B C

79 122 17 03H 0.94 0

<TS 774 E-50B C

40 123 18 VS4 0.49 0

<TS 775 E-50B C

42 123 32 VS4 0.71 0

<TS 776 E-50B C

118 123 23 04C

-1 0

<TS 777 E-50B C

1 124 16 02C 0.91 0

<TS 778 E-50B C

37 124 25 VS4

-0.79 0

<TS 779 E-50B C

37 124 26 VS4 0.93 0

<TS 780 E-50B C

55 124 17 VS3 0.72 0

<TS 781 E-50B C

69 124 12 03C

-0.72 0

<TS 782 E-50B C

91 124 13 04C 0.97 0

<TS 783 E-50B C

115 124 19 05C

-0.73 0

<TS 784 E-50B C

38 125 17 VS4

-1.04 0

<TS 785 E-50B C

38 125 36 VS4 0.92 0

<TS 786 E-50B C

56 125 15 VS4

-0.94 0

<TS 787 E-50B C

66 125 15 02C 0.83 0

<TS 788 E-50B C

72 125 19 06C 1.02 0

<TS 789 E-50B C

100 125 27 VS2

-0.65 0

<TS 790 E-50B C

100 125 29 VS2 0

0

<TS 791 E-50B C

100 125 15 VS4

-0.76 0

<TS 792 E-50B C

100 125 21 VS4 0.94 0

<TS 793 E-50B C

100 125 16 VS6 0

0

<TS 794 E-50B C

100 125 18 VS6 0.79 0

<TS 795 E-50B C

116 125 15 04C 0.19 0

<TS 796 E-50B C

116 125 18 04C 1

0

<TS 797 E-50B C

116 125 31 03C 0.97 0

<TS 798 E-50B C

33 126 18 VS4 0.7 0

<TS 799 E-50B C

45 126 19 02C 0.84 0

<TS 800 E-50B C

47 126 31 VS4

-0.91 0

<TS 801 E-50B C

47 126 31 VS4 1.06 0

<TS 802 E-50B C

63 126 15 VS3 0.98 0

<TS 803 E-50B C

69 126 13 VS5

-0.56 0

<TS 804 E-50B C

81 126 20 07C 0.78 0

<TS 805 E-50B C

103 126 18 04H 0.93 0

<TS 806 E-50B C

103 126 28 VS2 0

0

<TS 807 E-50B C

103 126 32 VS6 0.77 0

<TS 808 E-50B C

109 126 24 04H 0.78 0

<TS 809 E-50B C

109 126 13 VS4 0.96 0

<TS 810 E-50B C

38 127 27 VS4 0.97 0

<TS 811 E-50B C

44 127 22 02C 0.89 0

<TS 812 E-50B C

74 127 20 DBH

-1.62 0

<TS 813 E-50B C

76 127 16 DBH

-1.18 0

<TS 50

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 814 E-50B C

112 127 28 03C

-0.03 0

<TS 815 E-50B C

114 127 18 03C 0.96 0

<TS 816 E-50B C

37 128 21 VS4

-0.55 0

<TS 817 E-50B C

37 128 22 VS4 1.04 0

<TS 818 E-50B C

47 128 28 VS4

-0.85 0

<TS 819 E-50B C

53 128 19 03C 1.13 0

<TS 820 E-50B C

69 128 12 03C 0.97 0

<TS 821 E-50B C

73 128 18 VS4 0.03 0

<TS 822 E-50B C

79 128 12 03C 0.92 0

<TS 823 E-50B C

115 128 16 VS4

-0.86 0

<TS 824 E-50B C

46 129 22 VS4 0.84 0

<TS 825 E-50B C

48 129 13 03C

-0.08 0

<TS 826 E-50B C

56 129 12 03C

-0.91 0

<TS 827 E-50B C

56 129 20 03C 1.01 0

<TS 828 E-50B C

70 129 16 06C

-0.81 0

<TS 829 E-50B C

72 129 16 VS5

-0.91 0

<TS 830 E-50B C

15 130 24 05C

-0.8 0

<TS 831 E-50B C

45 130 17 VS4 1.15 0

<TS 832 E-50B C

103 130 15 VS2

-0.27 0

<TS 833 E-50B C

105 130 20 VS2

-0.84 0

<TS 834 E-50B C

105 130 14 VS2

-0.27 0

<TS 835 E-50B C

105 130 16 VS2 0.83 0

<TS 836 E-50B C

105 130 24 03C 0.78 0

<TS 837 E-50B C

107 130 20 03H 0.82 0

<TS 838 E-50B C

109 130 29 02C 0.83 0

<TS 839 E-50B C

111 130 22 VS4 0.96 0

<TS 840 E-50B C

113 130 22 VS4

-0.81 0

<TS 841 E-50B C

38 131 17 VS4

-0.97 0

<TS 842 E-50B C

38 131 23 VS4 1.06 0

<TS 843 E-50B C

44 131 20 03C 1.08 0

<TS 844 E-50B C

48 131 17 VS4

-0.63 0

<TS 845 E-50B C

52 131 27 VS5

-0.62 0

<TS 846 E-50B C

108 131 16 03C 0.12 0

<TS 847 E-50B C

108 131 24 02C 0.83 0

<TS 848 E-50B C

110 131 16 03C

-0.88 0

<TS 849 E-50B C

110 131 27 03C 0.9 0

<TS 850 E-50B C

110 131 16 02C

-0.83 0

<TS 851 E-50B C

110 131 7

02C 0.06 0

<TS 852 E-50B C

110 131 16 02C 0.79 0

<TS 853 E-50B C

39 132 39 VS4 0.7 0

<TS 854 E-50B C

39 132 18 03C 1.13 0

<TS 855 E-50B C

41 132 17 VS4 0.84 0

<TS 856 E-50B C

43 132 14 VS4 1

0

<TS 857 E-50B C

45 132 17 VS4 0.85 0

<TS 858 E-50B C

47 132 14 VS4

-0.69 0

<TS 859 E-50B C

47 132 16 VS4 1.06 0

<TS 860 E-50B C

53 132 20 02C 0.81 0

<TS 861 E-50B C

59 132 11 VS4

-0.75 0

<TS 51

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 862 E-50B C

63 132 18 VS3 0.77 0

<TS 863 E-50B C

71 132 13 VS5 0.99 0

<TS 864 E-50B C

99 132 20 VS2

-0.79 0

<TS 865 E-50B C

99 132 24 VS2 0.77 0

<TS 866 E-50B C

99 132 10 VS4

-0.84 0

<TS 867 E-50B C

99 132 16 VS4 0.9 0

<TS 868 E-50B C

103 132 16 VS2 0.03 0

<TS 869 E-50B C

107 132 25 03C 1

0

<TS 870 E-50B C

109 132 17 05C 0.97 0

<TS 871 E-50B C

109 132 18 04C 0.14 0

<TS 872 E-50B C

22 133 24 VS4 0.64 0

<TS 873 E-50B C

34 133 19 03C 1.01 0

<TS 874 E-50B C

60 133 19 03C

-0.78 0

<TS 875 E-50B C

100 133 15 VS4

-0.71 0

<TS 876 E-50B C

108 133 15 02C 0.28 0

<TS 877 E-50B C

39 134 26 VS4

-1 0

<TS 878 E-50B C

39 134 19 VS4 0.82 0

<TS 879 E-50B C

41 134 14 03C 0.98 0

<TS 880 E-50B C

51 134 14 03C

-0.83 0

<TS 881 E-50B C

53 134 17 03C 1.01 0

<TS 882 E-50B C

67 134 23 06C

-0.97 0

<TS 883 E-50B C

67 134 14 03C 0.75 0

<TS 884 E-50B C

69 134 18 VS3

-0.52 0

<TS 885 E-50B C

69 134 32 VS4

-0.59 0

<TS 886 E-50B C

69 134 29 VS4 0.85 0

<TS 887 E-50B C

69 134 18 VS5

-0.56 0

<TS 888 E-50B C

105 134 25 02C 0.83 0

<TS 889 E-50B C

38 135 20 VS4 0.21 0

<TS 890 E-50B C

46 135 15 VS4

-0.51 0

<TS 891 E-50B C

64 135 12 VS3

-0.73 0

<TS 892 E-50B C

98 135 22 VS2 0

0

<TS 893 E-50B C

98 135 25 VS4

-0.56 0

<TS 894 E-50B C

98 135 26 VS4 0.89 0

<TS 895 E-50B C

104 135 17 VS4 0.84 0

<TS 896 E-50B C

45 136 11 VS4

-0.61 0

<TS 897 E-50B C

63 136 13 VS5 0.82 0

<TS 898 E-50B C

69 136 17 VS5

-0.99 0

<TS 899 E-50B C

69 136 12 VS5 0.93 0

<TS 900 E-50B C

71 136 15 06C

-0.83 0

<TS 901 E-50B C

71 136 10 06C

-0.14 0

<TS 902 E-50B C

99 136 15 04C 0.89 0

<TS 903 E-50B C

101 136 12 03H 0.84 0

<TS 904 E-50B C

103 136 16 VS4 0.96 0

<TS 905 E-50B C

6 137 16 04C

-0.92 0

<TS 906 E-50B C

96 137 11 VS4

-0.31 0

<TS 907 E-50B C

96 137 20 VS4 0.9 0

<TS 908 E-50B C

96 137 17 04C

-0.06 0

<TS 909 E-50B C

102 137 12 VS4

-0.84 0

<TS 52

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 910 E-50B C

102 137 17 VS4 0.9 0

<TS 911 E-50B C

63 138 18 03C 0.72 0

<TS 912 E-50B C

67 138 22 VS3 0

0

<TS 913 E-50B C

67 138 18 03C 0

0

<TS 914 E-50B C

67 138 22 03C 0.83 0

<TS 915 E-50B C

95 138 39 VS4 0.83 0

<TS 916 E-50B C

99 138 17 DBH 2.18 0

<TS 917 E-50B C

96 139 16 VS2 0.98 0

<TS 918 E-50B C

96 139 21 03C

-0.89 0

<TS 919 E-50B C

96 139 12 03C 0.83 0

<TS 920 E-50B C

98 139 26 VS4 0.44 0

<TS 921 E-50B C

98 139 21 VS4 0.71 0

<TS 922 E-50B C

45 140 20 VS4 0.88 0

<TS 923 E-50B C

47 140 17 VS4 0.91 0

<TS 924 E-50B C

69 140 18 VS5

-0.95 0

<TS 925 E-50B C

69 140 11 VS5 0.77 0

<TS 926 E-50B C

83 140 12 VS3

-0.71 0

<TS 927 E-50B C

95 140 17 03C

-1.08 0

<TS 928 E-50B C

97 140 15 VS4

-0.9 0

<TS 929 E-50B C

18 141 14 03C

-1.07 0

<TS 930 E-50B C

70 141 16 VS3

-0.77 0

<TS 931 E-50B C

76 141 17 DBH 1.7 0

<TS 932 E-50B C

78 141 10 VS3

-0.81 0

<TS 933 E-50B C

78 141 10 VS4

-0.83 0

<TS 934 E-50B C

96 141 17 VS2 1.1 0

<TS 935 E-50B C

96 141 20 VS4 0.49 0

<TS 936 E-50B C

49 142 18 DBC

-0.47 0

<TS 937 E-50B C

95 142 23 VS4 0.99 0

<TS 938 E-50B C

95 142 13 VS6

-0.87 0

<TS 939 E-50B C

2 143 17 02C 0.99 0

<TS 940 E-50B C

68 143 16 06H 0.75 0

<TS 941 E-50B C

82 143 28 VS3

-0.61 0

<TS 942 E-50B C

82 143 20 VS4

-0.49 0

<TS 943 E-50B C

55 144 19 VS3

-0.39 0

<TS 944 E-50B C

61 144 14 06H 0.76 0

<TS 945 E-50B C

69 144 16 VS3

-0.89 0

<TS 946 E-50B C

69 144 21 VS5

-0.95 0

<TS 947 E-50B C

71 144 28 VS3

-0.97 0

<TS 948 E-50B C

71 144 19 VS3 1

0

<TS 949 E-50B C

91 144 14 VS4

-0.84 0

<TS 950 E-50B C

91 144 14 VS4 0.92 0

<TS 951 E-50B C

38 145 10 VS4

-0.94 0

<TS 952 E-50B C

38 145 13 VS4 0.97 0

<TS 953 E-50B C

56 145 18 04C

-0.78 0

<TS 954 E-50B C

80 145 31 VS4

-0.7 0

<TS 955 E-50B C

80 145 21 VS5 0.89 0

<TS 956 E-50B C

82 145 24 VS3

-0.59 0

<TS 957 E-50B C

82 145 18 VS3 1.02 0

<TS 53

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 958 E-50B C

82 145 19 VS4

-0.62 0

<TS 959 E-50B C

82 145 27 VS4 0.95 0

<TS 960 E-50B C

49 146 14 VS4

-0.33 0

<TS 961 E-50B C

71 146 17 VS4 1.15 0

<TS 962 E-50B C

71 146 30 VS5

-1.03 0

<TS 963 E-50B C

87 146 20 VS4

-0.64 0

<TS 964 E-50B C

87 146 31 03C 0.89 0

<TS 965 E-50B C

38 147 23 VS4

-1.09 0

<TS 966 E-50B C

38 147 11 VS4 0.97 0

<TS 967 E-50B C

66 147 13 VS3

-0.92 0

<TS 968 E-50B C

66 147 14 VS3 0.89 0

<TS 969 E-50B C

70 147 15 VS3

-0.85 0

<TS 970 E-50B C

37 148 19 VS4

-1 0

<TS 971 E-50B C

45 148 10 VS4

-0.85 0

<TS 972 E-50B C

45 148 13 VS4 0.94 0

<TS 973 E-50B C

45 148 15 06C

-0.28 0

<TS 974 E-50B C

47 148 13 04C 0.95 0

<TS 975 E-50B C

81 148 14 VS4

-0.93 0

<TS 976 E-50B C

81 148 17 VS4 1.06 0

<TS 977 E-50B C

81 148 17 04C 0.84 0

<TS 978 E-50B C

83 148 22 VS4

-0.96 0

<TS 979 E-50B C

4 149 8

04C

-0.85 0

<TS 980 E-50B C

66 149 19 06H 0.84 0

<TS 981 E-50B C

72 149 27 DBH 1.68 0

<TS 982 E-50B C

80 149 21 01H

-0.76 0

<TS 983 E-50B C

1 150 17 0iC

-0.86 0

<TS 984 E-50B C

1 150 17 0iC

-0.14 0

<TS 985 E-50B C

39 150 23 VS4 0.85 0

<TS 986 E-50B C

67 150 16 VS3

-0.7 0

<TS 987 E-50B C

67 150 16 VS3 0.9 0

<TS 988 E-50B C

69 150 23 VS3

-0.78 0

<TS 989 E-50B C

69 150 18 VS3 0.87 0

<TS 990 E-50B C

69 150 11 VS4 0.92 0

<TS 991 E-50B C

69 150 16 VS5 0.77 0

<TS 992 E-50B C

77 150 22 DBH 2

0

<TS 993 E-50B C

77 150 9

VS3

-0.84 0

<TS 994 E-50B C

77 150 13 VS4

-0.82 0

<TS 995 E-50B C

77 150 19 VS4 0.82 0

<TS 996 E-50B C

46 151 27 VS4 0.73 0

<TS 997 E-50B C

68 151 19 VS3

-0.67 0

<TS 998 E-50B C

68 151 10 VS5 0.83 0

<TS 999 E-50B C

71 152 13 VS4 0.83 0

<TS 1000 E-50B C

71 152 16 VS5 0.96 0

<TS 1001 E-50B C

30 153 13 VS4

-0.52 0

<TS 1002 E-50B C

70 153 14 VS4

-0.86 0

<TS 1003 E-50B C

70 153 13 VS4 0.91 0

<TS 1004 E-50B C

70 153 15 03C 0.19 0

<TS 1005 E-50B C

37 154 16 VS4

-0.06 0

<TS 54

NO.

S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEVTO STATUS 1006 E-50B C

41 154 11 VS4

-0.8 0

<TS 1007 E-50B C

41 154 14 VS4 0.83 0

<TS 1008 E-50B C

61 154 11 VS5 0.86 0

<TS 1009 E-50B C

33 156 13 VS4

-0.86 0

<TS 1010 E-50B C

37 156 22 VS4

-0.79 0

<TS 1011 E-50B C

37 156 27 VS4 1.18 0

<TS 1012 E-50B C

51 156 20 VS5

-0.87 0

<TS 1013 E-50B C

50 157 22 01H

-0.97 0

<TS 1014 E-50B C

1 158 20 02C 0.91 0

<TS 1015 E-50B C

33 158 20 02C 0.84 0

<TS 1016 E-50B C

49 158 17 0iC 0.06 0

<TS 1017 E-50B C

44 159 13 01H

-1 0

<TS 1018 E-50B C

46 159 13 0iC 0.19 0

<TS 1019 E-50B H

1 160 11 04H

-0.14 0

<TS 1020 E-50B H

1 160 17 04H 0.89 0

<TS 1021 E-50B C

37 160 15 VS4

-0.56 0

<TS 1022 E-50B C

37 160 16 VS4 0.85 0

<TS 1023 E-50B C

39 160 17 02H 0.72 0

<TS 1024 E-50B C

38 161 26 02H 0.83 0

<TS 1025 E-50B H

2 163 15 02H 0.96 0

<TS 1026 E-50B C

22 163 17 02C 0.75 0

<TS 1027 E-50B C

1 164 21 02C

-0.85 0

<TS 1028 E-50B C

11 164 21 04C 0.84 0

<TS 1029 E-50B C

11 164 17 02C

-0.94 0

<TS 1030 E-50B C

19 164 19 02C 0.84 0

<TS 1031 E-50B C

2 165 18 o1C 0.93 0

<TS 1032 E-50B C

6 165 17 02C

-0.88 0

<TS 1033 E-50B C

8 165 19 02C

-0.89 0

<TS 1034 E-50B C

10 165 20 02H 0.7 0

<TS 55