Final Status Survey Final Report Phase VI Appendix A5 Survey Unit Release Record 9512-0000, Northwest Site Grounds (Non-Protected Area)

February 2007

CYAPCO FINAL STATUS SURVEY RELEASE RECORD NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 A*ekHarnmond Prepared By:

Reviewed By:

Approved By:

Date:

//1///, 7 FSS Engineer t~

ArpýDate:

c, 12~)

FSS Engineer Tecmieal Support Manager Date:

67 Revision 0

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION......................................................

3

2.

CLASSIFICATION BASIS................................................................

3

3.

DATA QUALITY OBJECTIVES (DQO)..........................................

5

4.

SU RV EY D ESIGN.............................................................................

8

5.

SURVEY IMPLEMENTATION.......................................................

11

6.

SU RV EY RESU LTS........................................................................

12

7.

QUALITY CONTROL....................................................................

16

8.

INVESTIGATIONS AND RESULTS.............................................

16

9.

REMEDIATION AND RESULTS...................................................

16

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......

16

11. DATA QUALITY ASSESSMENT (DQA).......................................

17

12. A N O M A L IE S....................................................................................

18

13. C O N C LU SIO N..................................................................................

18

14. A TTA CH M EN TS.............................................................................

19 14.1 - Figures (5 pages including cover) 14.2 Attachment 2 - Scan Results (5 pages including cover) 14.3 Attachment 3 - Laboratory Data (81 pages including cover) 14.4 Attachment 4 - DQA Results (13 pages including covers)

TOTAL 123 Revision 0

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9512-0000, Northwest Site Grounds, is designated as Final Status Survey (FSS) Class 3 and consists of approximately 30,701 m2 (7.58 acres) of open land area located approximately 0.007 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP) (see Attachment 1, Figure 1).

The Northwest Site Grounds survey unit is bounded as follows: on the west by the Connecticut River; Survey Area 9506-0000, 9514-0000, 9302-0000 and 9304-0001 are to the east; Survey Area 9304-0001 is to the south and the property boundary bounds this unit to the north (called north as oriented with the north to south flow of the Connecticut River). The survey unit is comprised of predominately flat open land that slopes, slightly, from east to west toward the Connecticut River. At the far northeastern end of the survey unit, the topography changes from flat to steep hillside. The hillside is covered with large trees and thick brush. At the southern most section of the survey unit, the area is a steep hillside that falls off to the Connecticut River.

Connecticut Yankee (CY) memorandum, CY-06-093, addresses the abandonment of buried pipes, concrete, and drains onsite that will remain in place at the completion of the decommissioning. The sidewalk and two (2) electric/telephone duct banks that traverse the site adjacent to the access road will be abandoned in place.

Sufficient radiological assessment has been performed to confirm that the components or structures will meet all applicable unrestricted release criteria.

The reference coordinates associated with this survey area are E002 through E008 by S039 through S064 (refer to License Termination Plan Section 5.4.4, Figure 5-2). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit.

Some areas contained in this rectangle may not be part of this survey area. The boundary of the survey area was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification." The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9512-0000 as Class 3 in May 2006.

The "Classification Basis Summary" conducted for this survey unit consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment (HSA) Supplement, "

Revision 0 3

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD c) Historic and current survey records review, d) Visual inspections and a "walk-down."

A review of the IOCFR50.75(g)(1) database report identified one (1) significant radiological event that may have impacted this survey area.

Several small areas of low-level radioactive contaminated material were found on facility grounds through routine testing. (PIR 80-37)

The radioactive material was removed and no further radioactive material was located.

The historical documents reviewed included the "'Results of Scoping Survey",

(performed during late 1997) and the "Historical Site Assessment". No additional information was provided that was pertinent to this survey unit.

A review of the "Initial and Supplemental Characterization Reports " as well as the previous "Classification Basis Summaries " also provided no additional pertinent information.

Final characterization was performed by Site Closure personnel in May of 2005 to obtain data of sufficient quality for Final Status Survey (FSS) planning purposes.

This sampling was performed under Survey Sampling Work Plan (SSWP) 05-05-014. Ten (10) soil samples were taken from ten (10) biased locations. All of the samples were analyzed on-site using gamma spectroscopy. Hard-to-Detect (HTD) analyses were conducted on one (1) of the ten (10) samples. The only plant-related radionuclide identified in the samples was Cs-137 (refer to Table 1).

Table 1 -

Basic Statistical Quantities for Cs-137 from the Characterization Survey Cs-137 Parameter (pCi/g)

Minimum Value:

5.44E-02 Maximum Value:

4.95E-01 Mean:

2.65E-01 Median:

2.31E-01 Standard Deviation:

1.47E-01 The FSS Engineer performed a visual inspection and walk-down during September 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

At the time of the walk-down the area was being used for storage of heavy equipment and over-flow parking.

Revision 0 4

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Based upon a review of the historical information and the results of the characterization survey data, it was concluded that there was a low probability for residual radioactivity in concentrations greater than the Derived Concentration Guideline Levels (DCGLs), justifying a final survey unit classification of Class 3.

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process is provided herein.

The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is defined as the null hypothesis.

Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that the level of residual activity in the survey unit exceeded the release criteria. Therefore, the survey unit would satisfy the primary objective of the Final Status Survey Plan (FSSP).

The primary objective of the FSSP was to demonstrate that the level of residual radioactivity in Survey Unit 9512-0000 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL),

existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Revision 0 5

Revision 0 5

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Equation 1:

HTotal=Hsoil (sediment) + HExisting GW + HFuture GW The total dose under the LTP criteria is twenty five (25) mrem/yr Total Effective Dose Equivalent (TEDE) from all three (3) components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above. (reference CY memo ISC 06-024)

This survey unit is considered affected by existing groundwater radioactive contamination (reference CY memo ISC 06-024). Therefore, the dose contribution from existing groundwater is two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no radioactive concrete foundations or footings remaining within the groundwater saturated zone in the area.

Therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.

Equation 2:

19 mrem/yrTotal= 17 mrem/yrsoil+2 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above.

The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL(s), and has been established for the radionuclides of concern as provided in Table 2.

Revision 0 6

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Table 2 -

Radionuclide Specific Base Case Soil DCGLs, Operational DCGLs and Required Minimum Detectable Concentrations Base Case Soil Operational Required MDC Radionuclide )

DCGL DCGL (pCi/g) (2)

(pCi/g) (3)

(pCi/g) (4)

H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1 OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 9.58E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.O1E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+01 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+O1 1.75E+01 1.03E+00 Cm-243/244 2.90E+0 1 1.97E+01 1.16E+00 (1)

(2)

(3)

(4)

(5)

Bold indicates those radionuclides considered to be Hard to Detect (HTD)

The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE The Operational DCGL is equivalent to seventeen (17) mrem/yr TEDE The required MDC is equivalent to one (1) mrem/yr TEDE Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Revision 0 7

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Characterization was performed in May of 2005 as discussed in Section 2. Cs-137 was found to be the only radionuclide of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 are provided in Table 1.

Laboratory DQOs and analysis results were to be reported as actual calculated results.

Results reported as less than Minimum Detectable Concentration (MDC) would not be accepted for FSS. Sample report summaries were to include unique sample identification, analytical method, radionuclide, result, and uncertainty of two standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".

The FSSP uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that Cs-137 would be the radionuclide of concern in survey unit 9512-0000 (refer to Section 3). The characterization survey did not identify any HTD radionuclides of concern for this survey unit.

Other radionuclides identified during FSS would be evaluated to ensure adequate survey design and compliance with the unity rule.

Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".

Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since the survey unit is a Class 3 and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. In addition, this approach was conservative since it included background Cs-137 as part of the sample set.

Revision 0 8

Revision 0 8

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans" to 2.69 pCi/g Cs-137 to maintain the relative shift (A/CT) in the range of 1 and 3.

The resulting relative shift was 2. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E).

The result of the COMPASS computer run showed adequate power for the survey design. Survey design specified fifteen (15) soil samples for non-parametric statistical testing.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."

Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A random grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 3 area.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Table 3 -

Sample Measurement Locations with Associated GPS Coordinates Designation Northing Easting 9512-0000-OO1F 236938.75 667501.04 9512-0000-002F 236609.40 668025.17 9512-0000-003F 237055.61 667329.83 9512-0000-004F 237282.99 667275.84 9512-0000-005F 237238.76 667268.76 9512-0000-006F 237085.20 667324.58 9512-0000-007F 237370.49 667155.29 9512-0000-009F 237222.97 667187.94 9512-0000-01OF 237124.15 667504.61 9512-0000-013F 237033.24 667448.53 Revision 0 9

Revision 0 9

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Table 3 - (continued)

Designation Northing Easting 9512-0000-014F/FS 236957.70 667636.66 9512-0000-015F 236681.41 667973.12 9512-0000-017F/FS 236562.14 668058.53 9512-0000-018F 237153.95 667352.35 9512-0000-019F 236541.30 668115.12 The sample location designations of Table 3 are not sequentially inclusive because of the necessity to relocate three (3) of the original sample locations 9512-0000-008F/FS, 9512-0000-011F and 9512-0000-012F as they were located outside the survey unit. The initial design of the survey unit included area that was not within the property boundary. This was discovered during implementation of FSS. Addendum 1 to FSSP 9512-0000 was written to address the collection of three (3) additional samples.

Sample locations 9512-0000-017F/FS, 9512-0000-018F and 9512-0000-019F were selected randomly, in accordance with the FSSP 9512-0000 Addendum 1, as determined by using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying and Marking Surface Sample Locations for Final Status Survey".

Judgmental sampling was included as a feature of this survey design to account for any anomalies identified in the field.

Sample location 9512-0000-016F was selected as a judgmental location.

The judgmental sample location was selected based on its proximity to an area where radioactive material previously located and removed in 1980 (PIR 80-37).

Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans " specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples or 13% were analyzed for HTDs, exceeding the required percentage. The two (2) samples that were tested were randomly selected for HTD radionuclide analyses using the Microsoft Excel "RAND" function.

Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in Table 2.

The implementation of survey specific quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RAND" function. The number of quality control samples exceeded the 5 % requirement.

Revision 0 10

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD The LTP specifies that scanning will be performed along with random and judgmental measurements (samples) in a Class 3 survey unit. The scanning for a Class 3 survey unit can be judgmental. Approximately 10% of this survey unit was scanned. Scanning was biased to areas where radioactive material was previously located and removed in 1980 (PIR 80-37). Table 4 provides a synopsis of the survey design.

Table 4 -

Synopsis of the Survey Design ()

Feature Design Criteria Basis Based on AutoCAD-LT and Survey Unit Land Area 30,701 m2 Visual Sample Plan calculations Type 1 and Type 2 errors were 0.05, sigma was 0.147 pCi/g Cs-137 the LBGR Number of Measurements 15 was adjusted to 2.76 pCi/g Cs-137 to maintain Relative Shift in the range of 1 and 3.

Grid Spacing NA Based on random grid Operational DCGL 5.38 pCi/g Cs-137 To achieve 17 mremlyr TEDE To achieve 17 mrem/yr TEDE (').The Operational Soil Investigation Level 5.38 pCi/g Cs-137 DCGL meets the LTP Criteria for a Class 3 survey unit.

Scan Coverage Approximately 10% of the Judgmental bases area Detectable over Administratively set to Scan Investigation Level achieve 17 mrem/yr TEDE background(I (1) The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024.)

5.

SURVEY IMPLEMENTATION Final Status Survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0027.

The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.

Revision 0 I1I Revision 0 11

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey.

The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Three (3) scan areas were established that constituted approximately 10% of the surface area of the Survey Unit 9512-0000. Grid lines, one meter wide, were established in each of the three (3) scan areas.

Background was established at the beginning of each grid line, prior to scanning, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 5,200 counts per minute (cpm) up to 8,700 cpm.

The E-600 was operated in the rate-meter mode and used with the audio response.

The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second in a serpentine pattern.

Fifteen (15) soil samples were collected for non-parametric statistical testing and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.

Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples. "

Two (2) samples (9512-0000-003F and 9512-0000-007F) were randomly selected for HTD radionuclide analysis by the off-site laboratory.

One (1) biased soil sample, 9512-0000-016F, was collected and analyzed by the offsite laboratory for gamma spectroscopy.

The implementation of survey specific quality control measures included the collection of two (2) split samples at locations 9512-0000-014F and 9512-0000-017F for "split sample" analysis by the off-site laboratory.

6.

SURVEY RESULTS All field survey activities were conducted in October 2006.

The areas were scanned in accordance with the FSSP in October 2006. There were two areas of elevated activity identified during the scanning process of the sample measurement locations.

The fifteen (15) sample fixed measurement locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations.

Revision 0 12

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Table 5 - Scan Results for Sample Measurement Locations Sample Highest Logged Action Level (1)

Measurement Reading (kcpm)

> Action Level (2)

Location (kcpm) 1 5.86 7.34 NO 2

8.45 8.73 NO 3

7.19 6.33 YES 4

8.57 8.84 NO 5

9.54 10.0 NO 6

7.27 8.60 NO 7

7.50 8.86 NO 9

6.15 7.34 NO 10 6.14 6.03 YES 13 6.46 7.08 NO 14 5.50 6.28 NO 15 7.64 9.16 NO 17 8.22 8.88 NO 18 6.63 7.84 NO 19 6.71 7.44 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) FSS sample plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level. Sample locations 9512-0000-003F and 9512-0000-01 OF were moved accordingly.

The scan areas, that comprised approximately 10% of the total surface area for the survey unit, were scanned for elevated radiation levels.

Table 6 provides an overview of the scan area survey. Scan results are provided in.

Revision 0 13

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Table 6 - Scan Area Results Range of Highest Range of Action

>Action Scan Logged Logged Level (1)

Level )

Area Reading Reading (kcpm)

(kcpm)

(kcpm) 1 6.74-8.71 8.71 8.32-9.51 NO 2

6.15-7.94 7.94 7.31-9.39 NO 3

6.00-6.77 6.77 6.82-8.14 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan.

(2) There were no elevated readings detected in the scan areas.

The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) - Charleston, South Carolina. The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy.

Gamma spectroscopy analysis was performed to the required MDC. Gamma spectroscopy results identified some radionuclides meeting the acceptance criteria for detection (i.e., a result greater than two standard deviations uncertainty). All could be de-selected or excluded using the 5% and 10% rule described in Section 4.

Cs-137 was identified in eleven (11) of the fifteen (15) samples. None of the samples exceeded the Operational DCGL.

Gamma spectroscopy sample analysis did not require further investigation.

A summary of the sample results is provided in Table 7.

Table 7 -

Summary of Soil Sample Results Cs-137 Fraction of the pCi/g Operational DCGL )

9512-0000-OOIF 2.49E-01 0.04 9512-0000-002F 1.60E-01 0.03 9512-0000-003F 3.32E-01 0.06 9512-0000-004F 3.05E-01 0.05 9512-0000-005F 6.12E-01 0.11 9512-0000-006F 3.64E-01 0.06 9512-0000-007F 5.80E-01 0.10 9512-0000-009F 2.28E-01 0.04 Revision 0 14 Revision 0 14

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD Table 7 -

(continued)

Cs-137 Fraction of the pCi/g Operational DCGL )

9512-0000-01OF

-2.67E-03 0.00 9512-0000-013F 4.53E-02 0.00 9512-0000-014F 6.72E-03 0.00 9512-0000-015F 1.35E-03 0.00 9512-0000-017F 6.83E-02 0.01 9512-0000-018F 1.93E-02 0.00 9512-0000-019F 3.1OE-02 0.00 (1) The Operational DCGLs from Table 2 is 5.38 pCi/g for Cs-137 to achieve seventeen (17) mrem/yr TEDE.

The off-site laboratory also processed two (2) samples for HTD analyses as required by the sample plan.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. HTD analysis identified some radionuclides meeting the acceptance criteria for detection (i.e., a result greater than two standard deviations uncertainty). All could be de-selected or excluded using the 5% and 10% rule described in Section 4. All analyses met the required MDC.

One (1) biased sample was collected at a location selected by FSS Supervision based on professional judgment and observation.

Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC. The detectable radionuclide concentrations were a very small fraction of the Operational DCGL. No further action or investigations were required.

A summary of the sample results is provided in Table 8.

Table 8 -

Biased Sample Results Cs-137 Fraction of the pCi/g Operational DCGL )

9506-0000-016F 2.28E-01 0.043 (1)

The Operational DCGLs from Table 2 is 5.38 pCi/g for Cs-137 to achieve a TEDE of seventeen (17) mrem/yr.

Revision 0 15

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. The data was evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " There was acceptable agreement between the split results at location 9512-0000-017F/FS.

The other split sample, 9512-0000-014F/FS, K-40, a natural radioisotope, was found to be present at acceptable level of agreement, therefore, the comparison was determined to be acceptable. There was no Cs-137 to compare in this sample.

The sample analysis vendor, General Engineering Laboratories (GEL) -

Charleston, South Carolina, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachment 2 for data and data quality analysis results.

8.

INVESTIGATIONS AND RESULTS Sample investigation levels were not exceeded during the implementation of FSS in this survey unit. Consequently, no investigations were required.

9.

REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS.

Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN Three (3) of the systematic samples (samples 9512-0000-008F/FS, 9512-0000-011F and 9512-0000-012F) initially identified for non-parametric testing fell outside of the survey unit. The initial design of the survey unit included area that was not within the property boundary. This was discovered during the implementation of the FSSP. Three additional random samples were selected for non-parametric testing, in accordance with Addendum 1 of the FSSP.

The random samples were numbered 9512-0000-017F/FS, 9512-0000-018F and 9512-0000-019F.

Revision 0 16

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment," for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the sign test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible.

Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 3.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). See Table 9.

Table 9 -

Basic Statistical Quantities for Cs-137 from the Final Status Survey Cs-137 I

pCi/g DCGLop:

5.38E+00 Minimum Value:

-2.67E-03 Maximum Value:

6.12E-01 Mean:

2.OOE-01 Median:

1.60E-01 Standard Deviation:

2.06E-01 The sample standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a change to the original LBGR to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.

Revision 0 17 Revision 0 17

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD The range of the data is approximately 2.98 standard deviations.

The difference between the mean and median was 38.6% of the standard deviation which indicates some skewness in the data.

The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 0.859.

All data, assessments, and graphical representations are provided in.

12.

ANOMALIES No anomalies were noted in the performance of this FSS.

13.

CONCLUSION Survey Unit 9512-0000 has met the final DQOs of the FSS. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation were not required.

The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit was properly designated as Class 3.

The soil of this survey area meets the requirements for unrestricted release as a Class 3 survey unit under the criteria and requirements of the HNP License Termination Plan (LTP).

The dose contribution from soil is 0.50 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). The dose contribution from existing groundwater is two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is therefore zero (0) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity is 2.5 mrem/yr TEDE. Therefore, Survey Unit 9512-0000 is acceptable for unrestricted release.

Revision 0 18

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD

14.

ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 19 Revision 0 19

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD ATTACHMENT 1 (FIGURES)

(

N

/I R,*MWc CDWf S*-ut

-V-ud~*

NvrbhhI9 _ 23S~W3 / Ebs" WJ&14 IA IN, Nan

'-I jxtUlTcU? WZRJ-r Connecticut Yankee Atomic Power Company Date By Figure 1 Site Map With Reference To Survey Unit 9512-0000 Dbr200 A.L6.

n1 C

Li Legn 0 = Sample Locaton 4'q----."1 n

0 0

4 I---

t~.a a

Notes 9

18 9

5 6

Connecticut Yankee Atomic Power Company 9512-0000 Sample Locations

C a3 47 Legend 0

0 I---

K ý 0 = Sample Location 0.305 0

-p If-Notes 0.068 0.228 0.612 0.045 0.364 0.160 o

0.023 ei Connecticut Yankee Atomic Power Company 9512-0000 Cs-13 7 Posting Plot

4 7 L

6 0 = Sample Location 0

=ScanArea Notes A

0 a

1__

Scan Area 2 a

Scan Area 1 Connecticut Yankee Atomic Power Company 9512-0000 FSS Scan Areas

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Survey Release Record Sample Location Scan Results Survey Unit 9512-0000 Sample Name 9512-00-SL-00-01-0 9512-00-SL-00-02-0 9512-00-SL-00-03-0 9512-00-SL-00-04-0 9512-00-SL-00-05-0 9512-00-SL-00-06-0 9512-00-SL-00-07-0 9512-00-SL-00-09-0 9512-00-SL-00-1 0-0 9512-00-SL-00-1 3-0 9512-00-SL-00-14-0 9512-00-SL-00-15-0 9512-00-SL-00-17-0 9512-00-SL-00-1 8-0 9512-00-SL-00-19-0

Background

(cOm) 6.21 E+03 7.49E+03 5.29E+03 7.60E+03 8.67E+03 7.37E+03 7.61 E+03 6.21 E+03 5.02E+03 5.98E+03 5.25E+03 7.89E+03 7.63E+03 6.67E+03 6.31 E+03 Action Level (CPM) 7.34E+03 8.73E+03 6.33E+03 8.84E+03 1.OOE+04 8.60E+03 8.86E+03 7.34E+03 6.03E+03 7.08E+03 6.28E+03 9.16E+03 8.88E+03 7.84E+03 7.44E+03 Results Above (corn)

AL 5.86E+03 8.45E+03 7.19E+03

+

8.57E+03 9.54E+03 7.27E+03 7.50E+03 6.15E+03 6.14E+03

+

6.46E+03 5.50E+03 7.64E+03 8.22E+03 6.63E+03 6.71 E+03 Log Date Log Time E600 S/N Probe S/N 10/25/2006 10/25/2006 10/25/2006 10/26/2006 10/26/2006 10/26/2006 10/25/2006 10/26/2006 10/26/2006 10/25/2006 10/26/2006 10/25/2006 10/25/2006 10/26/2006 10/25/2006 13:30:00 13:04:00 13:57:00 10:03:00 8:21:00 7:52:00 14:52:00 8:19:00 7:47:00 14:28:00 9:34:00 13:05:00 13:25:00 9:44:00 13:59:00 1116 1116 1116 1115 1114 1114 1112 1115 1115 1116 1115 1112 1112 1114 1112 1006 1006 1006 1001 1014 1014 1013 1001 1001 1006 1001 1013 1013 1014 1013 A I A -.

Survey Release Record Scan Area Results Survey Unit 9512-0000 9512-0000 SCAN AREA 1 Sample Name 9512-00-SC-01-01-0 9512-00-SC-01-02-0 9512-00-SC-01-03-0 9512-00-SC-01-04-0 9512-00-SC-01-05-0 9512-00-SC-01-06-0 9512-00-SC-01-07-0 9512-00-SC-01-08-0 9512-00-SC-01-09-0 9512-00-SC-01-10-0 9512-00-SC-01-11-0 9512-00-SC-01-12-0 9512-00-SC-01-13-0 9512-00-SC-01-14-0

Background

(cpm) 7.67E+03 7.54E+03 8.17E+03 7.15E+03 7.12E+03 7.54E+03 7.23E+03 7.28E+03 8.15E+03 8.20E+03 7.55E+03 7.39E+03 8.27E+03 8.22E+03 Action Level (CPM)

Results Above Log Date Log Time E600 SIN Probe SIN (cpm)

AL 8.92E+03 7.95E+03 10/24/2006 9:51:00 1112 8.78E+03 9.46E+03 8.36E+03 8.32E+03 8.78E+03 8.44E+03 8.50E+03 9.44E+03 9.49E+03 8.79E+03 8.62E+03 9.57E+03 9.51 E+03 8.12E+03 7.25E+03 6.88E+03 7.88E+03 7.84E+03 6.74E+03 7.27E+03 8.38E+03 8.71 E+03 8.11 E+03 6.89E+03 7.54E+03 8.32E+03 10/24/2006 10/24/2006 11/1/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 9:57:00 10:00:00 7:29:00 10:08:00 10:12:00 13:30:00 13:33:00 13:37:00 13:41:00 13:44:00 13:47:00 13:51:00 13:54:00 1112 1112 1112 1112 1112 1112 1112 1107 1107 1107 1112 1107 1107 1013 1013 1013 1013 1013 1013 1013 1013 1003 1003 1003 1013 1003 1003 A I A -

Survey Release Record Scan Area Results Survey Unit 9512-0000 9512-0000 SCAN AREA 2 Sample Name 9512-00-SC-02-01-0 9512-00-SC-02-02-0 9512-00-SC-02-03-0 9512-00-SC-02-04-0 9512-00-SC-02-05-0 9512-00-SC-02-06-0 9512-00-SC-02-07-0 9512-00-SC-02-08-0 9512-00-SC-02-09-0 9512-00-SC-02-1 0-0 9512-00-SC-02-11-0 9512-00-SC-02-12-0 9512-00-SC-02-13-0 9512-00-SC-02-14-0 9512-00-SC-02-15-0 9512-00-SC-02-16-0 9512-00-SC-02-17-0 9512-00-SC-02-18-0 9512-00-SC-02-19-0 9512-00-SC-02-20-0 9512-00-SC-02-21 -0 9512-00-SC-02-22-0 9512-00-SC-02-23-0

Background

(c.m) 7.63E+03 7.66E+03 6.61 E+03 6.75E+03 6.19E+03 6.86E+03 6.80E+03 7.30E+03 6.93E+03 8.1OE+03 7.34E+03 6.92E+03 7.12E+03 7.20E+03 6.17E+03 7.30E+03 6.34E+03 6.57E+03 7.58E+03 6.72E+03 7.09E+03 6.50E+03 6.43E+03 Action Level fCPM) 8.88E+03 8.91 E+03 7.77E+03 7.92E+03 7.31 E+03 8.04E+03 7.98E+03 8.52E+03 8.12E+03 9.39E+03 8.56E+03 8.11 E+03 8.32E+03 8.41 E+03 7.29E+03 8.52E+03 7.48E+03 7.73E+03 8.82E+03 7.89E+03 8.29E+03 7.65E+03 7.58E+03 Results Above Log Date Log Time E600 S/N Probe S/N 7.18E+03 6.77E+03 6.73E+03 6.85E+03 7.02E+03 6.82E+03 7.68E+03 6.15E+03 7.79E+03 6.94E+03 7.73E+03 7.60E+03 7.44E+03 7.94E+03 6.89E+03 7.29E+03 7.06E+03 7.19E+03 7.06E+03 7.62E+03 7.07E+03 6.98E+03 7.45E+03 AL 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 10/24/2006 11/1/2006 10/24/2006 13:07:00 13:10:00 13:13:00 13:16:00 13:24:00 13:27:00 13:30:00 13:33:00 13:37:00 13:41:00 13:44:00 13:47:00 13:51:00 13:54:00 13:57:00 14:01:00 14:42:00 14:18:00 14:21:00 14:25:00 14:30:00 7:45:00 14:38:00 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1112 1107 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1013 1003

Survey Release Record Scan Area Results Survey Unit 9512-0000 9512-0000 SCAN AREA 3

Background

Action Level Results Above Log Date Log Time E600 SIN Probe SIN Sample Name (cpm)

(cDm)

(cpm)

AL 9512-00-SC-03-01 -0 6.12E+03 7.24E+03 6.OOE+03 10/2412006 14:09:00 1112 1013 9512-00-SC-03-02-0 6.19E+03 7.31E+03 6.21E+03 10/24/2006 14:13:00 1112 1013 9512-00-SC-03-03-0 6.62E+03 7.78E+03 6.15E+03 10/24/2006 14:15:00 1112 1013 9512-00-SC-03-04-0 5.74E+03 6.82E+03 6.12E+03 10/24/2006 14:19:00 1112 1013 9512-00-SC-03-05-0 6.44E+03 7.59E+03 6.22E+03 10/24/2006 14:23:00 1112 1013 9512-00-SC-03-06-0 6.77E+03 7.94E+03 6.77E+03 10/24/2006 14:26:00 1112 1013 9512-00-SC-03-07-0 6.32E+03 7.46E+03 6.42E+03 10/24/2006 14:29:00 1112 1013 9512-00-SC-03-08-0 6.95E+03 8.14E+03 6.50E+03 10/24/2006 14:32:00 1112 1013 9512-00-SC-03-09-0 5.75E+03 6.83E+03 6.29E+03 10/24/2006 14:49:00 1112 1013

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 175288 SDG: MSR#06-1425 November 06,2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on November 01, 2006 for analysis. Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Identification 175288001 175288002 175288003 175288004 175288005 175288006 175288007 175288008 175288009 175288010 175288011 175288012 175288013 175288014 175288015 175288016 175288017 175288018 Sample Description 9512-00-01OF 9512-00-006F 9512-00-005F 9512-00-009F 9512-00-014F 9512-00-014FS 9512-00-018F 9512-00-004F 9512-00-002F 9512-00-015F 9512-00-017F 9512-00-017FS 9512-00-O0IF 9512-00-019F 9512-00-003F 9512-00-016F 9512-00-013F 9512-00-007F Items of Note There are no items to note.

Case Narrative GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171 " Fax-43) 766-1178 www.get.com

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL)

Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Sixteen soil samples were analyzed for FSSGAM. Two soil samples were analyzed for FSSALL.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

ChPecl ones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171 Fex3a43) 786-1178 www.gel.com

List of current GEL Certifications as of 01 November 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SC012 Michigan 9903 Nevada SC12 New Jersey SC002 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 4

Chain of Custody and Supporting Documentation 5

C?)

0 0

0 Id~

0) 0ý kn C14 0

0 0

10 CM 0

40 z~z C.)

0.

rjj

.0 CC.

U-u c"

0 I.

.I.1.-

i-

.*-'.q-i.

E E

0u~

  • 0 E

ci~

.4-.

C0 0U NN S',.

0 El on

~0CO Ca-0

-)

0r 1.I I

I 2C1 01IVS W0)

S X1<1 I>

+/-

I CL v 0.4 0

0 0

uJ CE

.0 00 E m U)00 0

U) 0 aj 0

u, CY D

CO z0 66 LI 0

C.)

Ci EO C)

C) u.

0 E

0 z

Em z

Q C14 C'?

Ci o o 900 U

C) 4-0

(

Cd =O

-6 co~0 cd o 0 0

NM 00 El El d

C)

I.-

9-cc 1 r 00 00 C)

CD CD C 00 IMN Irr) Ir 'IN C

-, cN I

-rN IC 01ol I, oN I

ICD C01(=0C0 C)

C:

0 C0 0

0 0

0 CM I/N ON

'.0 0

0 0

C CM

'IN ON (a,

fL, ON CM

-"a.

0 C

0 CM If N ON C-i) 0 C

0 CM

'I-,

ON CD C14 01 0*

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00643 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use OOily.

Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: []30 D.E)14 D.N 7 D.l 3 D.

Container 7

2S /

Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9512-00-002F 10/25/06 1302 TS G

BP X

512-00-015F 10/25/06 1306 TS G

BP X

,9512-00-017F 10/25/06 1318 TS G

BP X

/'9512-00-017FS 10/25/06 1318 TS G

BP X

-'51.2-00-00IF 10/25/06 1327 TS G

BP X

4'1512-00-019F 10/25/06 1400 TS G

BP X

,9512-00-003F 10/25/06 1355 TS G

BP X

,9512-00-016F 10/25/06 1416 TS G

BP X

/9512-00-013F 10/25/06 1426 TS G

BP X

4512-00-007F 10/25/06 1450 TS G

BP X

NOTES: PO #: 002332 MSR #: 06-,*v& SSWP# NA M LTP QA E] Radwaste QA

[I Non QA

1) Relm i isheo y

Date/Time

2) Received By Date/Time
3) R~elinquished By Date/Time
4) Received By Date/Time Samples Shipped Via:

M Fed Ex II1 UPS

[] Hand DI Other 7?Blr 7f2V7 L

9adi Bill of Lading I#

Internal Container Temnp.:

F7 Deg.

C-Custody. Sealed?

Y Jý-N [1 Cust'ody Sea]

intact?

Y JŽN El

Connecticut Yankee Statement of Work for Analytical Lab Services

-CY-ISC-SOW-001 Figure 1. *Sample Check in List i

io 0o Date/Time Received:

c fl.qn i-Work Order Number:

1 t-"-S

-79 86. 00-39 I9i55_0 -.*1,7o Shipping Cdntainer ID:

/A5 3,3H-7 951?5/- -ihain of Custody

1.

Custody Seals oad shipping container intact?,..

2.

Custody Seals dated and signed?

3.

Chain-of-Custoiy record present?

4.

Cooler.temperature

-- 0w0cg

/,

5.

.Vermiculite/packing materials is:*

6.'

Number of samples in shipping container:

7.

Sample holding times exceeded?

a000 0- w OLqa,

.Yes t.zjlNo[

Yes'ifo[J Yes (tJ4ooI Wet []Dry Yes [

No W

.8. Samples have:

.t__pe

_hazard labels custody seals

-appropriate sample labels

9. Samples are:'

_____in good condition leaking

___broken

_____have air bubbles

10.

Were any anomalies identified in sample receipt?

Yes t] No 4-I...

  • Description of anomalies (include sample numbers):

Sample Custodian/Laboratory:

&.i Telephoned to:

_On f)~t~*

Dat IIV CP41~o

Data Review Qualifier Definitions 9

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound c

Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL c sample value < PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is

>10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC).

Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification x

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171, FaLJ3) 766-1178 www.gel.com

RADIOLOGICAL ANALYSIS 11

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 175288 Method/Analysis Information Product:

Alphaspec Am241, Cm, Solid ALL FSS Analytical Method:

DOE EML HASL-300, Am-05-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 584744 584632 584631 Sample ID 175288015 175288018 1201220201 1201220202 1201220203 1201220204 Client ID 9512-00-003F 9512-00-007F Method Blank (MB) 175290002(9106-0007-021F) Sample Duplicate (DUP) 175290002(9106-0007-021F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

12

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 175290002 (9106-0007-021F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 13

Product:

Alphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-I I-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 584747 584632 584631 Sample ID 175288015 175288018 1201220218 1201220219 1201220220 1201220221 Client ID 9512-00-003F 9512-00-007F Method Blank (MB) 175290002(9106-0007-021F) Sample Duplicate (DUP) 175290002(9106-0007-021F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC' Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 175290002 (9106-0007-021F).

QC Information All of the QC samples met the required acceptance limits.

14

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-I 1-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 584751 584632 584631 15

Sample ID Client ID 175288015 9512-00-003F 175288018 9512-00-007F 1201220222 Method Blank (MB) 1201220223 175290002(9106-0007-021F) Sample Duplicate (DUP) 1201220224 175290002(9106-0007-021F) Matrix Spike (MS) 1201220225 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 175290002 (9106-0007-021F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were recounted due to quench number being outside calibration range.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 16

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Sample ID 175288001 175288002 175288003 175288004 175288005 175288006 175288007 175288008 175288009 175288010 175288011 175288012 175288013 175288014 175288015 175288016 175288017 175288018 1201222576 1201222577 1201222578 Gamma,Solld-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 585612 584631 Client ID 9512-00-01OF 9512-00-006F 9512-00-005F 9512-00-009F 9512-00-014F 9512-00-014FS 9512-00-018F 9512-00-004F 9512-00-002F 9512-00-015F 9512-00-017F 9512-00-017FS 9512-00-00IF 9512-00-019F 9512-00-003F 9512-00-016F 9512-00-013F 9512-00-007F Method Blank (MB) 175288001(9512-00-01 OF) Sample Duplicate (DUP)

Laboratory Control Sample (LCS) 17

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 175288001 (9512-00-010F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and the duplicate, 1201222577 (9512-00-010F) and 175288001 (9512-00-010F), did not meet the relative percent difference requirement for Bi-214 and Ra-226, however they do meet the relative error ratio requirement with value of 2.12175 1.8

Oualifier information Qualifier U'

Reason Data rejected due to interference.

Data rejected due to low abundance.

U' Analyte Cesium-134 Europium-155 Manganese-54 Americium-241 Cesium-134 Niobium-94 Sample 175288013 175288016 175288013 175288018 175288013 175288017 175288001 175288003 175288004 175288005 175288008 175288009 175288010 175288011 175288012 175288014 175288015 175288017 175288018 175288012 Method/Analysis Information 19

Product:

GFPC, Sr90, solid - 0.025 pCi/g Analytical Method:

EPA 905.0 Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 584652 584632 584631 Sample ID 175288015 175288018 1201219935 1201219936 1201219937 1201219938 Client ID 9512-00-003F 9512-00-007F Method Blank (MB) 175288015(9512-00-003F) Sample Duplicate (DUP) 175288015(9512-00-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 175288015 (9512-00-003F).

QC Information All of the QC samples met the required acceptance limits.

20

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201219935 (MB) and 175288015 (9512-00-003F) were recounted due to high MDAs.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS DOE EML HASL-300, Tc-02-RC Modified Analytical Method:

Analytical Batch Number:

584644 Sample ID 175288015 175288018 1201219905 1201219906 1201219907 1201219908 Client ID 9512-00-003F 9512-00-007F Method Blank (MB) 175288015(9512-00-003F) Sample Duplicate (DUP) 175288015(9512-00-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this 21

narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 175288015 (9512-00-003F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 22

Product:

Liquid Scint Fe55, Solid-ALL FSS Analytical Method:

DOE RESL Fe-1, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 584650 584632 584631 Sample ID 175288015 175288018 1201219928 1201219929 1201219930 1201219931 Client ID 9512-00-003F 9512-00-007F Method Blank (MB) 175288015(9512-00-003F) Sample Duplicate (DUP) 175288015(9512-00-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 175288015 (9512-00-003F).

QC Information All of the QC samples met the required acceptance limits.

23

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-1, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 584649 584632 584631 Sample ID 175288015 175288018 1201219924 1201219925 1201219926 1201219927 Client ID 9512-00-003F 9512-00-007F Method Blank (MB) 175288015(9512-00-003F) Sample Duplicate (DUP) 175288015(9512-00-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS) 24

SOPReference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 175288015 (9512-00-003F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

25

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

LSC, Tritium Dist, Solid - 3 pCi/g Analytical Method:

Analytical Batch Number:

Sample ED 175288015 175288018 1201223381 1201223382 1201223383 1201223384 EPA 906.0 Modified 585989 Client ID 9512-00-003F 9512-00-007F Method Blank (MB) 175288015(9512-00-003F) Sample Duplicate (DUP) 175288015(9512-00-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 175288015 (9512-00-003F).

QC Information All of the QC samples met the required acceptance limits.

26

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201223381 (MB), 175288015 (9512-00-003F) and 175288018 (9512-00-007F) were reprepped due to high relative percent difference/relative error ratio.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:

NCR 380628 was generated due to Container scanning event for custody missed. 1. The analyst did not scan the samples 175288 015,018, 175290 002 into the batch prior to analysis, however the samples did remain in their custody at all times. 1. The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Solid Ali,FSS EPA EERF C-01 Modified Analytical Method:

Analytical Batch Number:

584648 Sample ID 175288015 175288018 1201219920 1201219921 1201219922 1201219923 Client ID 9512-00-003F 9512-00-007F Method Blank (MB) 175288018(9512-00-007F) Sample Duplicate (DUP) 175288018(9512-00-007F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General 27

Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 175288018 (9512-00-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 1201219920 (MB) was recounted due to the quench number being outside the calibration range. Samples 1201219922 (9512-00-007F) and 1201219923 (LCS) were recounted due to analyst error.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

28

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

Y F

29

General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.:

380628 Revision No.:

1 COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.

Division:

Quality Criteria:

Type:

08-NOV-06 Radiochemistry Specifications Process Instrument Type:

Test/ Method:

Matrix Type:

Client Code:

LSC EPA 906.0 Modified Solid YANK Batch ID:

Sample Numbers:

585989 See Below Potentially affected work order(s)(SDG): 175288(MSR#06-1425),175290(MSR#06-1310)

Application Issues:

Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

Description:

1. The analyst did not scan the samples 175288 015,018, 175290 002
1. The error has been corrected and the analyst has been instructed on the into the batch prior to analysis, however the samples did remain in their proper scanning procedures.

custody at all times.

Originator's Name:

Amy Scott Quality Review:

Data Validator/Group Leader:

Heather Anderson 08-NOV-06 08-NOV-06 Director:

Page 1 30

SAMPLE DATA

SUMMARY

31

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1425 GEL Work Order: 175288 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MIDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 32

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

9512-00-O0OF Project:

YANK01204 Sample ID:

175288001 ClientID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

26-OCT-06 Receive Date:

01-NOV-06 Collector:

Client Moisture:

4.27%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.673

+/-0.128 Americium-241 U

-0.0211

+/-0.0623 Bismuth-212 0.426

+/-0.192 Bismuth-214 0.404

+/-0.0624 Cesium-134 UI 0.00

+/-0.0215 Cesium-137 U -0.00276

+/-0.016 Cobalt-60 U

-0.0111

+/-0.016 Europium-152 U

0.0027

+/-0.0421 Europium-154 U

-0.022

+/-0.0486 Europium-t55 U

0.0578

+/-0.0544 Lead-212 0.612

+/-0.0489 Lead-214 0.558

+/-0.0655 Manganese-54 U

0.0218

+/-0.0214 Niobium-94 U

-0.0128

+/-0.0147 Potassium-40 9.85

+/-0.594 Radium-226 0.404

+/-0.0624 Silver-108m U 0.000905

+/-0.0131 Thallium-208 0.185

+/-0.0323 0.0504 0.0509 0.0882 0.0258 0.0172 0.0134 0.0127 0.0362 0.0402 0.0387 0.0203 0.0245 0.0135 0.0116 0.111 0.0258 0.0116 0.0124

+/-0.128

+/-0.0623

+/-0.192

+/-0.0624

+/-0.0215

+/-0.016

+/-0.016

+/-0.0421

+/-0.0486

+/-0.0544

+/-0.0489

+/-0.0655

+/-0.0214

+/-0.0147

+/-0.594

+/-0.0624

+/-0.0131

+/-0.0323 0.107 0.105 0.188 0.0543 0.0361 0.0283 0.0277 0.0756 0.0864 0.0801 0.0422 0.0513 0.0285 0.0246 0.244 0.0543 0.0244 0.0263 pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/03/062024 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1051 584631 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defi'ed as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 33

GENERAL ENGINEERING LABORATORIES, LLC

.2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-OlOF Project:

YANK01204 SamplelD:

175288001 ClientID:

YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MI)A Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result Ui Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.915 Americium-241 U

0.0533 Bismuth-212 0.670 Bismuth-214 0.524 Cesium-134 U

0.0467 Cesium-137 0.364 Cobalt-60 U

0.00 Europium-152 U

0.0321 Europium-154 U

0.0589 Europium-155 U

0.0473 Lead-212 0.766 Lead-214 0.600 Manganese-54 U

0.0276 Niobium-94 U -0.00446 Potassium-40 12.6 Radium-226 0.524 Silver-108m U

0.0164 Thallium-208 0.235 9512-00-006F 175288002 TS 26-OCT-06 01-NOV-06 Client 24.6%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 icertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.271 k/-0.0445

+/-0.364

+/-0.153

+/-0.0329

+/-0.0846

+/-0.0377

+1-0.105

+1-0.116

+/-0.0831 F/-0.0996

+/-0.120

+/-0.0311 V/-0.0303

+/-1.33

+/-0.153

+/-0.0309

+/-0.0798 0.0966 0.0354 0.226 0.0528 0.0313 0.0291 0.0311 0.0633 0.102 0.0546 0.035 0.0459 0.0287 0.0257 0.191 0.0528 0.0238 0.0264

+/-0.271

+/-0.0445

+/-0.364

+/-0.153

+/-0.0329

+/-0.0846

+/-0.00

+/-0.105

+/-0.116

+/-0.0831

+/-0.0996

+/-0.120

+/-0.0311

+/-0.0303

+/-1.33

+/-0.153

+/-0.0309

+/-0.0798 0.193 0.0707 0.451 0.106 0.0626 0.0581 0.0622 0.127 0.204 0.109 0.070 0.0917 0.0573 0.0513 0.382 0.106 0.0475 0.0527 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g MJH1 11/03/062046 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1138 584631 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-006F Project:

YANK01204 Sample ID:

175288002 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

36

GENERAL ENGINEERING LABORATORIES, LLC

...2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Ana1v~is Certificateof A alvsis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-005F 175288003 TS 26-OCT-06 01-NOV-06 Client 26.4%

Proeect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Garnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 1.21 U

-0.0785 0.930 0.882 UI 0.00 0.612 U

0.00618 U

0.00712 U

0.0308 U

0.0598 1.25 0.951 U

-0.0195 U

0.0142 12.5 0.882 U

0.0241 0.404

+/-0.195

+/-0.133

+/-0.273

+/-0.127

+/-0.0379

+/-0.0717

+/-0.0255

+/-0.0693

+/-0.0795

+/-0.0661

+/-0.0782

+/-0.119

+/-0.025

+/-0.0243

+/-1.02

+/-0.127

+/-0.0216

+/-0.0686 0.0648 0.0938 0.164 0.0371 0.0274 0.0195 0.0217 0.0559 0.0684 0.0581 0.0299 0.040 0.0189 0.0208 0.180 0.0371 0.0194 0.0189

+/-0.195

+/-0.133

+/-0.273

+/-0.127

+/-0.0379

+/-0.0717

+/-0.0255

+/-0.0693

+/-0.0795

+/-0.0661

+/-0.0782

+/-0.119

+/-0.025

+/-0.0243

+/-1.02

+/-0.127

+/-0.0216

+/-0.0686 0.140 0.194 0.347 0.0784 0.0578 0.0415 0.0474 0.116 0.148 0.120 0.062 0.0833 0.0404 0.0437 0.400 0.0784 0.0407 0.0401 pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCilg pCi/g MJH1 11/04/060751 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1139 584631 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 37

GENERAL ENGINEERING LABORATORIES, LLC

.2040 Savage Road Charleston SC 29407 - (843) 556-8171 mwww.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-005F Proiect:

YANK01204 Sample ID:

175288003 Client ID:

YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

38

GENERAL ENGINEERING LABORATORIES, LLC

- 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Ana1v~is A

Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-009F 175288004 TS 26-OCT-06 01 -NOV-06 Client 15.7%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.672 U

-0.0211 0.524 0.458 UI 0.00 0.228 U

0.00973 U

-0.013 U

-0.0326 U

0.0373 0.688 0.534 U -0.00843 U

0.00866 13.1 0.458 U

0.00168 0.234

+/-0.111

+/-0.0808

+/-*0.157

+/-0.0641

+/-0.0241

+/-0.0275

+/-0.013

+/-0.0342

+/-0.0458

+/-0.052

+/-0.041

+/-0.0555

+/-0.0128

+/-0.0116

+/-0.606

+/-0.0641

+/-0.0107

+/-0.0333 0.0369 0.0644 0.0851 0.0204 0.0147 0.0113 0.0119 0.0304 0.0316 0.0374 0.0189 0.0212 0.0107 0.0105 0.0891 0.0204 0.00953 0.0102

+/-0.111

+/-0.0808

+/-0.157

+/-0.0641

+/-0.0241

+/-0.0275

+/-0.013

+/-0.0342

+/-0.0458

+/-0.052

+/-0.041

+/-0.0555

+/-0.0128

+/-0.0116

+/-0.606

+/-0.0641

+/-0.0107

+/-0.0333 0.0781 0.133 0.179 0.0427 0.0307 0.0237 0.0254 0.0631 0.0675 0.077 0.0389 0.044 0.0225 0.0219 0.194 0.0427 0.0199 0.0214 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/04/060802 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1139 584631 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-009F Project:

YANK01204 Sample ID:

175288004 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-014F 175288005 TS 26-OCT-06 01-NOV-06 Client 4.95%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.574

+/-0.0992 Americium-241 U

0.0388

+/-0.0487 Bismuth-212 0.346

+/-0.159 Bismuth-214 0.322

+/-0.0534 Cesium-134 U1 0.00

+/-0.0199 Cesium-137 U

0.00672

+/-0.0144 Cobalt-60 U

0.0118

+/-0.0133 Europium-152 U

-0.0376

+/-0.0384 Europium-154 U

-0.0156

+/-0.0337 Europium-155 U

0.00184

+/-0.0371 Lead-212 0.493

+/-0.0391 Lead-214 0.440

+/-0.0553 Manganese-54 U

0.00801

+/-0.0124 Niobium-94 U

0.00139

+/-0.0136 Potassium-40 9.59

+/-0.499 Radium-226 0.322

+/-0.0534 Silver-108m U

0.00384

+/-0.0109 Thallium-208 0.158

+/-0.0241 0.0351 0.0424 0.0826 0.0191 0.013 0.0111 0.0122 0.0271 0.0278 0.0334 0.0165 0.0181 0.0109 0.0101 0.081 0.0191 0.00993 0.00948

+/-0.0992

+/-0.0487

+/-0.159

+/-0.0534

+/-0.0199

+/-0.0144

+/-0.0133

+/-0.0384

+/-0.0337

+/-0.0371

+/-0.0391

+/-0.0553

+/-0.0124

+/-0.0136

+/-0.499

+/-0.0534

+/-0.0109

+/-0.0241 0.0744 0.0871 0.174 0.0401 0.0272 0.0232 0.0259 0.0563 0.060 0.0687 0.0341 0.0377 0.023 0.0211 0.178 0.0401 0.0207 0.020 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/04/060803 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1139 584631 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-014F Project:

YANK01204 Sample ID:

175288005 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of A alysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-014FS 175288006 TS 26-OCT-06 01-NOV-06 Client 4.92%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.548

+/-0.140 Americium-241 U

0.0172

+/-0.0255 Bismuth-212 0.290

+/-0.249 Bismuth-214 0.415

+1-0.0831 Cesium-134 U

0.0222

+/-0.0248 Cesium-137 U -0.00913

+/-0.0187 Cobalt-60 U

0.00689

+/-0.0218 Europium-152 U

0.00464

+/-0.0577 Europium-154 U

-0.0215

+/-0.0621 Europium-155 U

0.0204

+/-0.0444 Lead-212 0.565

+/-0.0656 Lead-214 0.432

+/-0.0747 Manganese-54 U

0.0264

+/-0.0259 Niobium-94 U

0.00349

+/-0.0164 Potassium-40 8.96

+/-0.787 Radium-226 0.415

+/-0.0831 Silver-108m U -0.00508

+/-0.0153 Thallium-208 0.201

+/-0.0358 0.0573 0.0219 0.134 0.0322 0.0211 0.0162 0.0191 0.0399 0.0506 0.0366 0.0208 0.0274 0.0188 0.0149 0.155 0.0322 0.0134 0.0157

+/-0.140

+/-0.0255

+/-0.249

+/-0.0831

+/-0.0248

+/-0.0187

+/-0.0218

+/-0.0577

+/-0.0621

+1-0.0444

+/-0.0656

+/-0.0747

+/-0.0259

+/-0.0164

+/-0.787

+/-0.0831

+/-0.0153

+/-0.0358 0.115 0.0438 0.267 0.0644 0.0421 0.0324 0.0382 0.0798 0.101 0.0731 0.0415 0.0547 0.0375 0.0297 0.310 0.0644 0.0267 0.0313 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/04/06 0841 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1139 584631 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-014FS Project:

YANK01204 Sample ID:

175288006 Client ID:

YANKOO1 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded 3

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-018F 175288007 TS 26-OCT-06 01-NOV-06 Client 8.19%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.484

+/-0.0824 Americium-241 U

0.00423

+/-0.0134 Bismuth-212 0.328

+1-0.114 Bismuth-214 0.292

+/-0.0497 Cesium-134 U

0.0157

+/-0.0156 Cesium-137 U

0.0193

+/-0.0159 Cobalt-60 U

0.00702

+/-0.0104 Europium-152 U

0.0066

+/-0.026 Europium-154 U

-0.0155

+/-0.0353 Europium-155 U

0.0126

+/-0.0269 Lead-212 0.466

+/-0.0291 Lead-214 0.353

+/-0.0422 Manganese-54 U

0.00584

+/-0.0109 Niobium-94 U -0.00465

+/-0.0104 Potassium-40 6.79

+/-0.462 Radium-226 0.292

+/-0.0497 Silver-108m U

0.00177

+/-0.00833 Thallium-208 0.158

+/-0.0244 0.0319 0.0109 0.0628 0.0165 0.0112 0.0104 0.00925 0.0223 0.0287 0.0187 0.0115 0.0155 0.00935 0.00858 0.0878 0.0165

+/-0.0824

+/-0.0134

+/-0.114

+/-0.0497

+/-0.0156

+/-0.0159

+/-0.0104

+/-0.026

+/-0.0353

+/-0.0269

+/-0.0291

+/-0.0422

+/-0.0109

+/-0.0104

+/-0.462

+/-0.0497 0.0673 0.0224 0.132 0.0345 0.0233 0.0217 0.0199 0.0461 0.0611 0.0384 0&0237 0.0321 0.0196 0.0179 0.190 0.0345 0.0156 0.0183 pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/04/06 1605 585612 1

0.00749 +/-0.00833 0.00877 +/-0.0244 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1139 584631 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-018F Project:

YANK01204 Sample ID:

175288007 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result U

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.34 Americiurn-241 U

-0.0019 Bismuth-212 0.754 Bismuth-214 0.900 Cesium-134 UI 0.00 Cesium-137 0.305 Cobalt-60 U

0.00202 Europium-152 U -0.00971 Europium-154 U

-0.0109 Europium-155 U

0.058 Lead-212 1.28 Lead-214 1.02 Manganese-54 U

0.0179 Niobium-94 U -0.00509 Potassium-40 11.7 Radium-226 0.900 Silver-108m U

0.0111 Thallium-208 0.400 9512-00-004F 175288008 TS 26-OCT-06 01-NOV-06 Client 16.8%

Proiect:

Client ID:

Vol. Recv.:

YAN'K01204 YANK001 ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.206

+/-0.0476

+/-0.263

+/-0.113

+/-0.0319

+/-0.045

+/-0.0149

+/-0.0425

+/-0.0434

+/-0.0507

+/-0.108

+/-0.109

+/-0.0139

+/-0.0137

+/-0.962

+/-0.113

+/-0.0134

+/-0.0497 0.0397 0.0388 0.0908 0.0222 0.0177 0.013 0.0127 0.0308 0.0361 0.0323 0.0175 0.0229 0.0128 0.0113 0.106 0.0222 0.0113 0.0127

+/-0.206

+/-0.0476

+/-0.263

+/-0.113

+/-0.0319

+/-0.045

+/-0.0149

+/-0.0425

+/-0.0434

+/-0.0507

+/-0.108

+/-0.109

+/-0.0139

+/-0.0137

+/-0.962

+/-0.113

+/-0.0134

+/-0.0497 0.0838 0.0792 0.190 0.0462 0.0367 0.0272 0.0271 0.0637 0.0768 0.066 0.036 0.0473 0.0267 0.0235 0.228 0.0462 0.0233 0.0265 pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCilg pCi/g MJH1 11/04/06 1605 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11101/06 1139 584631 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-004F Project:

YANK01204 Sample ID:

175288008 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MIDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL hI Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-002F 175288009 TS 25-OCT-06 01-NOV-06 Client 13%

Project:

YANK01204 Client ID:

YANKO00 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.714

+/-0.117 Americium-241 U

0.0428

+/-0.0428 Bismuth-212 0.407

+/-0.165 Bismuth-214 0.524

+/-0.0653 Cesium-134 UI 0.00

+/-0.0194 Cesium-137 0.160

+/-0.0231 Cobalt-60 U

0.00335

+/-0.0118 Europium-152 U

-0.0286

+/-0.0364 Europium-154 U

-0.0204

+/-0.0401 Europium-155 U-0.000292

+/-0.0323 Lead-212 0.726

+/-0.0665 Lead-214 0.590

+/-0.0686 Manganese-54 U

0.0164

+/-0.0131 Niobium-94 U

0.0178

+/-0.0136 Potassium-40 12.3

+/-0.878 Radium-226 0.524

+/-0.0653 Silver-108m U -0.00466

+/-0.0102 Thallium-208 0.233

+/-0.0296 0.034 0.0341 0.0717 0.0183 0.0124 0.0094 0.0101 0.0253 0.0328 0.0291 0.0155 0.0187 0.00889 0.00959 0.0933 0.0183 0.00874 0.00847

+/-0.117

+/-0.0428

+/-0.165

+/-0.0653

+/-0.0194

+/-0.0231

+/-0.0118

+/-0.0364

+/-0.0401

+/-0.0323

+/-0.0665

+/-0.0686

+/-0.0131

+/-0.0136

+/-0.878

+/-0.0653

+/-0.0102

+/-0.0296 0.068 0.0682 0.143 0.0366 0.0248 0.0188 0.0201 0.0506 0.0655 0.0581 0.031 0.0373 0.0178 0.0192 0.187 0.0366 0.0175 0.0169 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/04/06 1606 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 49

GENERAL ENGINEERING LABORATORIES, LLC

.2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-002F Project:

YANK01204 Sample ID:

175288009 Client ID:

YANK01I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wwWlgel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-015F 175288010 TS 25-OCT-06 01-NOV-06 Client 4.07%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganima,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Amnericium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-!55 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.648 U

0.0285 0.555 0.519 UI 0.00 U

0.00135 U

0.0192 U

-0.0294 U

-0.0206 U

0.0289 0.604 0.590 U

0.00387 U -0.00016 11.3 0.519 U -0.00216 0.181

+/-0.123

+/-0.0227

+/-0.233

+/-0.075

+/-0.0236

+/-0.0228

+/-0.0153

+/-0.0417

+/-0.0484

+/-0.0296

+1-0.0622

+/-0.0744

+/-0.0147

+/-0.0128

+/-0.698

+/-0.075

+/-0.012

+/-0.0348 0.0441 0.0178 0.0954 0.0224 0.0159 0.0129 0.015 0.0292 0.0395 0.0272 0.0155 0.0212 0.013 0.0113 0.113 0.0224 0.0105 0.011

+/-0.123

+/-0.0227

+/-0.233

+/-0.075

+/-0.0236

+/-0.0228

+/-0.0153

+/-0.0417

+/-0.0484

+/-0.0296

+/-0.0622

+/-0.0744

+/-0.0147

+/-0.0128

+/-0.698

+/-0.075

+/-0.012

+/-0.0348 0.0881 0.0357 0.191 0.0448 0.0317 0.0258 0.030 0.0584 0.079 0.0544 0.0309 0.0423 0.0261 0.0226 0.225 0.0448 0.0209 0.022 pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg MJHI 11/04/06 1607 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843)556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-015F Proiect:

YANK01204 Sample ID:

175288010 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

52

GENERAL ENGINEERING LABORATORIES, LLC

.. 2040 Savage Road Charleston SC 29407- (843) 556-8171 - WWW.gel.com Certificate of Analysis Certificate ofA alv-ds Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

9512-00-017F Project:

YANK01204 Sample ID:

175288011 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

25-OCT-06 Receive Date:

01-NOV-06 Collector:

Client Moisture:

8.78%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.637

+/-0.0927 Americium-241 U

0.0363

+1-0.0597 Bismuth-212 0.345

+1-0.157 Bismuth-214 0.552

+1-0.059 Cesium-134 UI 0.00

+/-0.0249 Cesium-137 0.0683

+/-0.0317 Cobalt-60 U

0.0105

+/-0.0114 Europium-152 U -0.0167

+/-0.0298 Europium-154 U

-0.0147

+/-0.0387 Europium-155 U

0.0182

+/-0.031 Lead-212 0.693

+/-0.0359 Lead-214 0.571

+/-0.0501 Manganese-54 U

0.00321

+/-0.0119 Niobium-94 U

0.00106

+/-0.0104 Potassium-40 9.24

+/-0.531 Radium-226 0.552

+/-0.059 Silver-108m U

0.00406

+/-0.00958 Thallium-208 0.232

+/-0.0264 0.0338 0.0497 0.0718 0.0176 0.0127 0.00905 0.0104 0.0248 0.032 0.0295 0.0152 0.0188 0.0102 0.00894 0.0969 0.0176

+/-0.0927

+/-0.0597

+/-0.157

+/-0.059

+/-0.0249

+/-0.0317

+/-0.0114

+/-0.0298

+/-0.0387

+/-0.031

+/-0.0359

+/-0.0501

+/-0.0119

+/-0.0104

+/-0.531

+/-0,059 0.0712 0.102 0.151 0.0368 0.0264 0.019 0.0222 0.0514 0.0679 0.0603 0.0312 0.0388 0.0214 0.0187 0.208 0.0368 0.0182 0.0215 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/04/06 1707 585612 1

0.00876 +/-0.00958 0.0103 +/-0.0264 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-017F Project:

YANK01204 Sample ID:

175288011 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gelcom Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-017FS 175288012 TS 25-OCT-06 01-NOV-06 Client 8.88%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.672 U

0.0487 0.409 0.467 UI 0.00 0.0598 U -0.00244 U

-0.0213 U

0.005 U

0.0565 0.621 0.584 U

0.0038 UI 0.00 9.75 0.467 U

0.00457 0.223

+/-0.0996

+/-0.0683

+/-0.197

+/-0.0453

+/-0.0203

+/-0.0169

+/-0.0115

+/-0.0289

+/-0.0363

+/-0.0307

+/-0.0347

+/-0.0495

+/-0.0114

+/-0.0194

+/-0.476

+/-0.0453

+/-0.00891

+/-0.0269 0.0298 0.0572 0.067 0.0177 0.0121 0.00891 0.00958 0.0239 0.0311 0.0303 0.015 0.0167 0.00976 0.00897 0.0863 0.0177

+/-0.0996

+/-0.0683

+/-0.197

+/-0.0453

+/-0.0203

+/-0.0169

+/-0.0115

+/-0.0289

+/-0.0363

+/-0.0307

+/-0.0347

+/-0.0495

+/-0.0114

+/-0.0194

+/-0.476

+/-0.0453 0.0629 0.117 0.141 0.0369 0.0251 0.0186 0.0205 0.0495 0.0658 0.0618 0.0307 0.0345 0.0204 0.0187 0.186 0.0369 0.017 0.0182 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/04/06 1713 585612 1

0.00821 +/-0.00891 0.00873 +/-0.0269 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-017FS Project:

YANK01204 Sample ID:

175288012 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-001F 175288013 TS 25-OCT-06 01-NOV-06 Client 27.4%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANKO01 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.02

+/-0.143 Americium-241 U -0.00964

+/-0.020 Bismuth-212 0.674

+/-0.209 Bismuth-214 0.614

+/-0.0673 Cesium-134 UI 0.00

+/-0.0252 Cesium-137 0.249

+/-0.0328 Cobalt-60 U -0.00252

+/-0.0172 Europium-152 U

0.0166

+/-0.0362 Europium-154 U

-0.0165

+/-0.0558 Europium-155 U!

0.00

+/-0.0478 Lead-212 0.972

+/-0.0491 Lead-214 0.701

+/-0.0716 Manganese-54 UI 0.00

+/-0.0296 Niobium-94 U 0.000854

+/-0.014 Potassium-40 14.1

+/-0.681 Radium-226 0.614

+/-0.0673 Silver-108m U -0.00305

+/-0.0134 Thallium-208 0.292

+/-0.039 0.0415 0.0178 0.103 0.0233 0.0138 0.0138 0.0143 0.0324 0.0397 0.0302 0.0191 0.0225 0.0126 0.0118 0.0987 0.0233 0.0115 0.0127

+/-0.143

+/-0.020

+/-0.209

+/-0.0673

+/-0.0252

+/-0.0328

+/-0.0172

+/-0.0362

+/-0.0558

+/-0.0478

+/-0.0491

+/-0.0716

+/-0.0296

+/-0.014

+/-0.681

+/-0.0673

+/-0.0134

+/-0.039 0.0878 0.0362 0.215 0.0484 0.0289 0.0287 0.0304 0.0669 0.0843 0.0617 0.0392 0.0465 0.0263 0.0246 0.216 0.0484 0.0238 0.0265 pCi/g pCi/g pCi/g pCi/g pCilg pCilgc pCilg pCilg pCilg pCilg pCi/g pCi/g pCi/g pCi/g pCilg pCilg pCi/g pCilg MJH1 11/04/06 1714 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-O0IF Proiect:

YANK01204 Sample ID:

175288013 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-019F 175288014 TS 25-OCT-06 01-NOV-06 Client 4.65%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.558

+/-0.0973 Americium-241 U -0.00653

+/-0.0518 Bismuth-212 0.417

+/-0.177 Bismuth-214 0.439

+/-0.0517 Cesium-134 UI 0.00

+/-0.0208 Cesium-137 0.031

+/-0.0196 Cobalt-60 U

0.0179

+/-0.0116 Europium-152 U

-0.0274

+/-0.032 Europium-154 U

0.0352

+/-0.0372 Europium-155 U

0.0338

+/-0.0291 Lead-212 0.494

+/-0.034 Lead-214 0.496

+/-0.0538 Manganese-54 U

0.00994

+/-0.0113 Niobium-94 U

0.00576

+/-0.0102 Potassium-40 8.61

+/-0.520 Radium-226 0.439

+/-0.0517 Silver-108m U -0.00993

+/-0.0104 Thallium-208 0.182

+/-0.0251 0.035 0.0424 0.0721 0.0171 0.0137 0.0106 0.0113 0.0268 0.0343 0.0286 0.0157 0.0188 0.0102 0.00921 0.0983 0.0171 0.00835 0.00978

+/-0.0973

+/-0.0518

+/-0.177

+/-0.0517

+/-0.0208

+/-0.0196

+/-0.0116

+/-0.032

+/-0.0372

+/-0.0291

+/-0.034

+/-0.0538

+/-0.0113

+/-0.0102

+/-0.520

+/-0.0517

+/-0.0104

+/-0.0251 0.0737 0.0868 0.152 0.0357 0.0284 0.0221 0.024 0.0554 0.0726 0.0584 0.0323 0.0389 0.0214 0.0192 0.211 0.0357 0.0174 0.0204 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/04/06 1714 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-019F Project:

YANK01204 Sample ID:

175288014 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171.- www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-003F 175288015 TS 25-OCT-06 01-NOV-06 Client 17.4%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U

0.135 Curium-242 U

0.003 Curium-243/244 U

-0.0893 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

0.0468 Plutonium-239/240 U

0.108 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

0.00

+/-0.254 0.180

+/-0.255

+/-0.115 0.0951

+/-0.115

+/-0.166 0.168

+/-0.167

+/-0.0877 0.039 +/-0.0878 0.457 0.292 0.433 0.161 0.161 16.1 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA 11/03/06 0749 584744 1

1 MXA 11/03/06 0749 584747 2

1

+/-0.122 0.039

+/-0.123

+/-9.14 7.67

+/-9.14 MXA 1

11/07/06 1001 584751 3

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.877

+/-0.0946 Americium-241 U

0.00132

+/-0.0467 Bismuth-212 0.430

+/-0.154 Bismuth-214 0.469

+/-0.0605 Cesium-134 UI 0.00

+/-0.0199 Cesium-137 0.332

+/-0.0314 Cobalt-60 U -0.00483

+/-0.0122 Europium-152 U

0.0384

+/-0.0286 Europium-154 U

-0.0308

+/-0.0369 Europium-155 U

0.0286

+/-0.0319 Lead-212 0.712

+/-0.0372 Lead-214 0.567

+/-0.0539 Manganese-54 U 0.000228

+/-0.0115 Niobium-94 U-0.000419

+/-0.0106 Potassium-40 11.9

+/-0.554 Radium-226 0.469

+/-0.0605 Silver-108m U

0.00798

+/-0.0104 Thallium-208 0.211

+/-0.0282 Rad Gas Flow Proportional Counting 0.0335 0.0438 0.0749 0.0173 0.0131 0.0102 0.00987 0.0268 0.0293 0.0296 0.0154 0.0179 0.0101 0.00894 0.0783 0.0173 0.00942 0.00958

+/-0.0946

+/-0.0467

+/-0.154

+/-0.0605

+/-0.0199

+/-0.0314

+/-0.0122

+/-0.0286

+/-0.0369

+/-0.0319

+/-0.0372

+/-0.0539

+/-0.0115

+/-0.0106

+/-0.554

+/-0.0605

+/-0.0104

+/-0.0282 0.0703 0.0893 0.156 0.036 0.0272 0.0213 0.021 0.0552 0.062 0.0603 0.0315 0.0369 0.0211 0.0186 0.169 0.036 0.0194 0.0199 0.016 pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCilg pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/04/06 1710 585612 5

KSDI 11/07/06 1103 584652 6

GFPC, Sr90, solid - 0.025 pCi/g Strontium-90 Rad Liquid Scintillation Analysis 0.0264

+/-0.0119 0.00695 +/-0.0119 61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 " (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

9512-00-003F 175288015 Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritiun Dist, Solid -

3 pCi/g Tritium U

0.178 Liquid Scint C14, Solid All, FSS Carbon-14 U

-0.0691 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

-20.5 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-1.75 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.0477

+/-0.744 0.613

+/-0.744

+/-0.122 0.104

+/-0.122

+/-52.3 39.0

+/-52.3 1.32 pCi/g 0.212 81.5 pCi/g pCilg pCi/g pCi/g DFA1 11/07/06 1718 585989 7

AXD2 11/03/060413 584648 10 MXP1 11/03/06 1512 584650 11 MXPI 11/06/06 1230 584649 12 KXR1 11/06/06 0714 584644 13

+/-9.40 7.95

+/-9.40 16.5

+/-0.270 0.225

+/-0.270 0.465 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description 1

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-11-RC Modified 3

DOE EML HASL-300, Pu-1 1-RC Modified 4

DOE EML HASL-300, Pu-lI -RC Modified 5

EML HASL 300, 4.5.2.3 6

EPA 905.0 Modified 7

EPA 906.0 Modified 8

EPA 906.0 Modified 9

EPA 906.0 Modified 10 EPA EERF C-01 Modified 11 DOE RESL Fe-1, Modified 12 DOE RESL Ni-i, Modified 13 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Alphaspec Am24 1, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS 87 94 (15%-125%)

(15%-125%)

62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 -www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

9512-00-003F 175288015 Proiect:

YANKO1204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Plutonium-241 Strontium-90 Carrier/Tracer Recovery Iron-55 Nickel-63 Carrier/Tracer Recovery Technetium-99 Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý GFPC, Sr9O, solid - 0.025 pCi/g GFPC, Sr9O, solid - 0.025 pCi/g Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 82 72 72 67 88 88 75 75 (25%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407.- (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-016F 175288016 TS 25-OCT-06 01 -NOV-06 Client 28.8%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actiniumn-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.848 U

0.00581 0.505 0.597 UI 0.00 0.228 U

0.009 U -0.00605 U

0.00481 U

0.0755 0.856 0.640 U

0.0185 U 0.000615 13.2 0.597 U

-0.0114 0.274

+/-0.148

+/-0.112

+/-0.185

+/-0.0838

+/-0.0238

+/-0.0392

+/-0.0148

+/-0.0368

+/-0.0504

+/-0.0433

+/-0.0816

+/-0.0811

+/-0.0136

+/-0.0132

+/-1.04

+/-0.0838

+/-0.0128

+/-0.0402 0,040 0.087 0.0874 0.0219 0.0124 0.0125 0.0131 0.0312 0.0376 0.038 0.0173 0.022 0.0122 0.0113 0.110 0.0219 0.0103 0.0116

+/-0.148

+/-0.112

+/-0.185

+/-0.0838

+/-0.0238

+/-0.0392

+/-0.0148

+/-0.0368

+/-0.0504

+/-0.0433

+/-0.0816

+/-0.0811

+/-0.0136

+/-0.0132

+/-1.04

+/-0.0838

+/-0.0128

+/-0.0402 0.0839 0.177 0.182 0.0455 0.026 0.026 0.0278 0.0642 0.0795 0.0774 0.0354 0.0454 0.0255 0.0235 0.235 0.0455 0.0213 0.0241 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/04/06 1710 585612 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-016F Project:

YANK01204 Sample ID:

175288016 Client ID:

YANK001 Vol. Recv.:

.Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample 1D:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-013F 175288017 TS 25-OCT-06 01-NOV-06 Client 15.3%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganrna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.634

+/-0.105 Americium-241 UI 0.00

+/-0.0386 Bismuth-212 0.416

+/-0.178 Bismuth-214 0.557

+/-0.0681 Cesium-134 UI 0.00

+/-0.021 Cesium-137 0.0453

+/-0.0174 Cobalt-60 U -0.00114

+/-0.0101 Europium-152 U

-0.0134

+/-0.031 Europium-154 U

-0.0275

+/-0.0331 Europium-155 U

0.0266

+/-0.0305 Lead-212 0.699

+/-0.0634 Lead-214 0.630

+/-0.0699 Manganese-54 U

0.00909

+/-0.00907 Niobium-94 U

0.00367

+/-0.00968 Potassium-40 10.7

+/-0.747 Radium-226 0.557

+/-0.0681 Silver-108m U

0.0029

+/-0.011 Thallium-208 0.225

+/-0.0299 0.0288 0.0334 0.0647 0.0171 0.0119 0.00989 0.00858 0.024 0.0271 0.0286 0.0145 0.017

+/-0.105

+/-0.0386

+/-0.178

+/-0.0681

+/-0.021

+1-0.0174

+/-0.0101

+/-0.031

+/-0.0331

+1-0.0305

+/-0.0634

+/-0.0699 0.0603 0.0677 0.135 0.0352 0.0246 0.0205 0.0182 0.0493 0.057 0.0581 0.0297 0.0349 0.0176 0.0176 0.142 0.0352 0.017 0.0179 pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCilg pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/04/06 1711 585612 1

0.00842 +/-0.00907 0.00852 +/-0.00968 0.0657

+/-0.747 0.0171 +/-0.0681 0.00823

+/-0.011 0.00864 +/-0.0299 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description 1

EML HASL,300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 -www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 8, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9512-00-013F Project:

YANK01204 Sample ID:

175288017 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MEDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

November 8, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9512-00-007F 175288018 TS 25-OCT-06 01-NOV-06 Client 31.7%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U

-0.134 Curium-242 U

-0.0418 Curium-243/244 U

-0.0174 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

-0.0136 Plutonium-239/240 U

0.0148 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

-3.43

+/-0.0868 0.108 +/-0.0873

+/-0.0367 0.0699

+/-0.037

+1-0.165 0.144

+/-0.165

+/-0.0588 0.0361 +/-0.0589

+/-0.0588 0.0361 +/-0.0588

+/-7.18 6.18

+/-7.18 Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 Americium-241 U

0.00711 Bismuth-212 1.10 Bismuth-214 0.656 Cesium-134 UI 0.00 Cesium-137 0.580 Cobalt-60 U

0.00358 Europium-152 U

-0.0382 Europium-154 U

0.0107 Europium-155 UI 0.00 Lead-212 0.947 Lead-214 0.742 Manganese-54 U

0.0184 Niobium-94 U

0.00423 Potassium--40 15.9 Radium-226 0.656 Silver-I08m U

0.00366 Thallium-208 0.301 Rad Gas Flow Proportional Counting GFPC, Sr90, solid - 0.025 pCi/g Strontium-90 0.0356 Rad Liquid Scintillation Analysis

+/-0.171

+/-0.0259

+/-0.290

+/-0.0915

+/-0.0383

+/-0.0449

+/-0.0191

+/-0.0492

+/-0.0607

+/-0.0715

+/-0.0525

+/-0.0742

+/-0.0269

+/-0.0179

+/-0.780

+/-0.0915

+/-0.016

+/-0.0484

+/-0.0191 0.0591 0.0222 0.127 0.0298 0.0213 0.0169 0.0161 0.0398 0.0511 0.0327 0.0211 0.0302 0.0168 0.0151 0.152 0.0298 0.0141 0.0165

+/-0.171

+/-0.0259

+/-0.290

+/-0.0915

+/-0.0383

+/-0.0449

+/-0.0191

+/-0.0492

+/-0.0607

+/-0.0715

+/-0.0525

+/-0.0742

+/-0.0269

+/-0.0179

+/-0.780

+/-0.0915

+/-0.016

+/-0.0484 0.308 0.234 0.379 0.149 0.149 13.0 0.123 0.0451 0.263 0.0616 0.044 0.0349 0.034 0.0817 0.107 0.0667 0.0431 0.062 0.0348 0.0313 0.323 0.0616 0.029 0.034 0.0263 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA 11/03/06 0749 584744 1

1 MXA 11/03/06 0749 584747 2

1 MXA 11/07/06 1017 584751 3

1 MJ-H1 11/04/06 1715 585612 5

KSD1 11/03/06 1524 584652 6

0.011 +/-0.0192 68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

9512-00-007F 175288018 Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g Tritium U

-0.529 Liquid Scint C14, Solid All,FSS Carbon-14 U

-0.013 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

6.40 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

2.37 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.0522 Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mtd

+/-0.760 0.673

+/-0.760

+/-0.127 0.106

+/-0.127

+/-37.7 27.4

+/-37.7

+/-10.5 8.72

+/-10.5

+/-0,267 0.223

+/-0.267 1.44 0.217 57.4 18.1 0.460 pCilg pCilg pCilg pCi/g pCi/g DFAI 11/07/06 1820 585989 7

AXD2 11/03/06 0505 584648 10 MXPI 11/03/06 1529 584650 11 MXP1 11/06/06 1246 584649 12 KXR1 11/06/060731 584644 13 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 11/01/06 1142 584631 The following Analytical Methods were performed Method Description 1

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-11-RC Modified 3

DOE EML HASL-300, Pu-i 1-RC Modified 4

DOE EMI HASL-300, Pu-11-RC Modified 5

EML HASL 300, 4.5.2.3 6

EPA 905.0 Modified 7

EPA 906.0 Modified 8

EPA 906.0 Modified 9

EPA 906.0 Modified 10 EPA EERF C-01 Modified 11 DOE RESL Fe-1, Modified 12 DOE RESL Ni-i, Modified 13 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Arnericium-243 Plutonium-242 Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Recovery%

80 96 Acceptable Limits (15%-125%)

(15%-125%)

69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 8, 2006 Client Sample ID:

Sample ID:

9512-00-007F 175288018 Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Plutonium-241 Liquid Scint Pu241. Solid-ALL F5 102 (25%-125%)

Strontium-90 Carrier/Tracer Recovery Iron-55 Nickel-63 Carrier/Tracer Recovery Technetium-99 Carrier/Tracer Recovery GFPC, Sr90, solid - 0.025 pCi/g GFPC, Sr90, solid - 0.025 pCi/g Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 89 89 72 87 87 75 75 (25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

70

QUALITY CONTROL DATA 71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 - www.gel.com QC Summary Client:

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: November 8,2006 Page 1 of 9 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

175288 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Alpha Spec Batch 584744 QC1201220202 Americium-241 175290002 DUP Curium-242 Curium-243/244 QC 1201220204 LCS Americium-241 Curium-242 Curium-243/244 U

0.0491 Uncert:

+/-0.185 TPU:

+/-0.185 U

0.134 Uncert:

+/-0.303 TPU:

+/-0.303 U

0.224 Uncert:

+/-0.307 TPU:

+/-0.308 13.5 Uncert:

TPU:

Uncert:

TPU:

16.3 Uncert:

TPU:

U

-0.037

+/-0.122

+/-0.122 U

-0.0189

+/-0.159

+/-0.159 U

-0.0959

+/-0.292

+/-0.292 14.2

+/-1.38

+/-2.23 U

-0.0168

+/-0.0725

+/-0.0725 17.1

+/-1.52

+/-2.60 U

-0.0992

+/-0.126

+/-0.127 U

0.056

+/-0.126

+/-0.127 U

0.00871

+/-0.212

+/-0.212 pCi/g 1420 pCi/g 266 pCilg 499 pCi/g (0% -100%) 4XA1 11/03/06 07:49 (0% -100%)

(0%-100%)

105 (75%-125%)

QC1201220201 Americium-241 MB Curium-242 Uncert:

TPU:

Uncert:

TPU:

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g 105 (75%-125%)

Curium-243/244 QC 1201220203 Americium-241 175290002 MS Uncert:

TPU:

13.6 Uncert:

TPU:

Uncert:

TPU:

16.6 Uncert:

TPU:

U 0.0491

+/-0.185

+/-0.185 U

0.134

+/-0.303

+/-0.303 U

0.224

+/-0.307

+/-0.308 Curium-242 U

12.8

+/-1.38

+/-2.13 0.0501

+/-0.133

+/-0.133 16.8

+/-1.58

+/-2.65 94 (75%-125%)

Curium-243/244 101 (75%-125%)

Batch 584747 QC1201220219 175290002 DUP Plutonium-238 U

0.00833 U

0.00 pCig 200 (0% - 100%) AXA1 11/03/06 07:49 72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -.(843) 556-8.171 - www.gel.corn QC Summary Workorder:

175288 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Alpha Spec Batch 584747 Phutonium-239/240 Uncert:

+/-0.0631 TPU:

+/-0.0631 U

0.038 Uncert:

+/-0.0857 TPU:

+/-0.0857 QC1201220221 1.CS Plutonium-238 Plutonium-239/240 QC1201220218 MB Plutonium-238 Plutonium-239/240 QC1201220220 175290002 MS Plutonium-238 Plutonium-239/240 Uncert:

TPU:

12.5 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0586

+/-0.0586 U

0.00955

+/-0.0907

+/-0.0907 U

0.178

+/-0.266

+/-0.267 13.7

+/-1.54

+/-2.21 U

-0.00987

+/-0.0829

+/-0.083 U

-0.00987

+1-0.0829

+/-0.083 PCi/g PCi/g PCi/g PCi/g PCi/g PCi/g pCi/g 120 (0% - 100%)

(75%-125%)

11/03/06 07:49 110 (75%-125%)

11/03/06 07:49 u

0.00833 Uncert:

+/-0.0631 TPU:

+/-0.0631 12.6 U

0.038 Uncert:

- +/-0.0857 TPU:

+/-0.0857 u

3.26 Uncert:

+/-8.75 TPU:

+/-8.76 0.289

+/-0.200

+/-0.203 11.0

+/-1.20

+/-1.66 (75%-125%)

87 (75%-125%)

Batch 584751 QC1201220223 175290002 DUP Plutonium-241 QC1201220225 LCS Plutonium-241 QC1201220222 MB Plutonium-241 QC1201220224 175290002 MS Plutonium-241 Rad Gamma Spec Batch 585612 QC1201222577 175288001 DUP Actinium-228 U

-2.83

+/-7.80

+/-7.80 pCi/g 0

(0% - 100%) VXA1 143 Uncert:

TPU:

Uncert:

TPU:

146

, U Uncert:

TPU:

142

+/-19.1

+/-25.7 U

-4.48

+/-8.90

+/-8.90 PCi/g PCi/g PCi/g 99 (75%-125%)

11/07/06 11:06 11/07/06 11:39 11/07/06 10:50 11/07/06 11:22 3.26

+/-8.75

+/-8.76 128

+/-13.8

+/-19.2 88 (75%-125%)

0.673

+/-0.128 Uncert:

0.647

+/-0.109

+/-0.109 pCi/g 4

(0%- 100%) MJH1 11/04/06 17:06 73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 294.07 -1(843) 556-8171 - www.gel.corn QC Summary Workorder:

175288 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 585612 Aniericium-241 Bismuth-2 12 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:

+/-0.128 u

-0.0211 Uncert:

+/-0.0623 TPU:

+/-0.0623 0.426 Uncert:

+/-0.192 TPU:

+/-0.192 0.404 Uncert:

+/-0.0624 TPU:

+/-0.0624 UI 0.00 Uncert:

+/-0.0215 TPU:

+/-0.0215 U

-0.00276 Uncert:

+/-0.016 TPU:

+/-0.016 U

-0.0111 Uncert:

+/-0.016 TPU:

+/-0.016 U

0.0027 Uncert:

+/-0.0421 TPU:

+/-0.0421 U

-0.022 Uncert:

+/-0.0486 TPU:

+/-0.0486 U

0.0578 Uncert:

+/-0.0544 TPU:

+/-0.0544 0.612 Uncert:

+/-0.0489 TPU:

+/-0.0489 0.558 Uncert:

+/-0.0655 TPU:

+/-0.0655 U

0.0218 Uncert:

+/-0.0214 TPU:

+/-0.0214 U

-0.0128 Uncert:

+/-0.0147 TPU:

+/-0.0147 9.85 Uncert:

+/-0.594 TPU:

+/-0.594 0.404 Uncert:

+/-0.0624 TPU:

+/-0.0624 U

0.000905 Uncert:

+/-0.0131 U

0.00554

+/-0.0527

+/-0.0527 0.416

+/-0.179

+/-0.179 0.505

+/-0.0702

+/-0.0702 U

0.0113

+/-0.0236

+/-0.0236 U

0.00161

+/-0.0123

+/-0.0123 U

0.0135

+/-0.0139

+/-0.0139 U

-0.00261

+/-0.0404

+/-0.0404 U

0.00369

+/-0.0366

+/-0.0366 U

0.0297

+/-0.0451

+/-0.0451 0.675

+/-0.0666

+/-0.0666 0.560

+/-0.0698

+/-0.0698 U

-0.000765

+/-0.0125

+/-0.0125 U

-0.00673

+/-0.0114

+/-0.0114 9.06

+/-0.729

+/-0.729 0.505

+/-0.0702

+/-0.0702 U

-0.00715

+/-0.011 pCilg 342 pCi/g 3

pCilg 22 pCi/g 130 pCi/g 759 pCi/g 2090 pCi/g 200 pCi/g 280 pCi/g 64 pClg 10 pCi/g 0

pCilg 200 pCilg 200 pCi/g 8

pCi/g 22 pCilg 200 (0% - 100%)

(0%- 100%)

(0% - 100%)

(0%- 100%)

(0% - 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0% - 20%)

(0% - 20%)

(0%- 100%)

(0%- 100%)

(0%-20%)

(0% - 100%)

(0%- 100%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-lO8m 74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder:

175288 Page 4 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Timi Rad Gamma Spec Batch 585612 e

Thallium-208 TPU:

+/-0.0131 0.185 Uncert:

+/-0.0323 TPU:

+/-0.0323

+/-0.011 0.181

+/-0.0328

+/-0.0328 pCi/g 2

(0% - 100%)

QC1201222578 Actinium-228 Americium-24 I LCS Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-1 55 Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.54 Uncert:

TPU:

14.2 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.115

+/-0.248

+/-0.248 24.3

+/-0.234

+/-0.234 U

0.0978

+/-0.365

+/-0.365 U

0.0897

+/-0.0917

+/-0.0917 U

-0.00517

+/-0.0559

+/-0.0559 10.5

+/-0.187

+/-0.187 15.2

+/-0.250

+/-0.250 U

-0.0164

+/-0.0974

+/-0.0974 U

-0.0205

+/-0.102

+/-0.102 U

-0.0362

+/-0.0824

+/-0.0824 U

0.0045

+/-0.0684

+/-0.0684 U

0.000938

+/-0.0721

+/-0.0721 U

-0.00555

+/-0.0507

+/-0.0507 U

-0.0445

+/-0.0419

+/-0.0419 U

0.455 pci/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 110 (75%-125%)

107 (75%-125%)

104 (75%-125%)

11/04/06 17:06 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.corm QC Summary Workorder:

175288 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 585612 Radium-226 Silver-108m Thallium-208 QC1201222576 MB Actinium-228 Americium-241 B3ismuth-212 B3ismutLh-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-1 55 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.363

+/-0.363 U

0.0897 pCilg

+/-0.0917

+/-0.0917 U

-0.00252 pCi/g

+/-0.0399

+/-0.0399 U

0.0196 pCi/g

+/-0.0446

+/-0.0446 U

0.0232 pCilg

+/-0.0382

+/-0.0382 U

0.0133 pCi/g

+/-0.0331

+/-0.0331 U

0.0153 pCi/g

+/-0.0386

+/-0.0386 U

0.00701 pCi/g

+/-0.0311

+/-0.0311 U

-0.00104 pCilg

+/-0.00572

+/-0.00572 U

0.00215 pCi/g

+/-0.00537

+/-0.00537 U

-0.00015 pCi/g

+/-0.00538

+/-0.00538 U

0.0175 pCi/g

+/-0.0136

+/-0.0136 U

0.00143 pCi/g

+/-0.0168

+/-0.0168 U

0.00185 pCi/g

+/-0.0153

+/-0.0153 U

0.00297 pCi/g

+/-0.0137

+/-0.0137 U

0.0159 pCi/g

+/-0.021

+/-0.021 11/04106 17:06 (75%-125%)

L~ead-212 Lead-214 76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comr QC Summary Workorder:

175288 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 585612 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Rad Gas Flow Batch Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.00475

+/-0.00931

+/-0.00931 U

0.000918

+1-0.005

+1-0.005 U

0.0596

+/-0.131

+/-0.131 U

0.00701

+1-0.0311

+/-0.0311 U -2.OOOE-05

+/-0.00452

+/-0.00452 U

0.008

+/-0.0102

+/-0.0102 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 584652 QC1201219936 Strontium-90 175288015 DUP 0.0264 Uncert:

+/-0.0119 TPU:

+/-0.0119 QC1201219938 LCS Strontium-90 QC1201219935 MB Stiontium-90 QC1201219937 175288015 MS Strontium-90 Rad Liquid Scintillation Batch 584644 QC1201219906 175288015 DUP Technetium-99 QC1201219908 LCS Technetium-99 QC1201219905 MIB Technetium-99 0.0609

+/-0.0184

+/-0.0185 1.05

+/-0.107

+/-0.110 pCilg 79*

(0%- 100%) KSDI 1.18 Uncert:

TPU:

Uncert:

TPU:

2.20 Uncert:

TPU:

U 0.00653

+/-0.00814

+/-0.00814 pCi/g pCi/g pCilg 89 (75%-125%)

11/03/06 15:25 11/03/06 16:37 11/07/06 11:03 11/03/06 15:44 0.0264

+/-0.0119

+/-0.0119 1.71

+/-0.188

+/-0.192 77 (75%-125%)

U 0.0477 Uncert:

+/-0.270 TPU:

+/-0.270 U

-0.0932

+/-0.255

+/-0.255 12.2

+/-0.489

+/-0.576 pCi/g 0

(0% - 100%) KXR1 13.0 Uncert:

TPU:

pCi/g 94 (75%-125%)

11/06/06 08:20 11/06/06 08:53 11/06/06 08:03 U

-0.00874 pCi/g 77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary AXI I-A-0 1 17C') QQ r

Page 7 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Liquid Scintillation Batch 584644 Uncert:

TPU:

QC1201219907 175288015 MS Technetium-99 13.0 U

Uncert:

TPU:

0.0477

+/-0.270

+/-0.270 Batch 584648

+/-0.231

+/-0.231 12.2

+/-0.513

+/-0.596

-0.0381

+/-0.119

+/-0.119 6.38

+/-0.376

+/-0.389 pCi/g 93 (75%-125%)

11/06/06 08:36 QC1201219921 175288018 DUP Carbon-14 U

-0.013 Uncert:

+/-0.127 TPU:

+/-0.127 U

pCi/g 0

(0% - 100%) kXD2 QC1201219923 LCS Carbon-14

" QC1201219920 MB Carbon-14 6.74 Uncert:

TPU:

Uncert:

TPU:

6.99 U

Uncert:

TPU:

U 0.0531

+/-0.108

+/-0.108 pCi/g pCi/g pCilg 95 (75%-125%)

11/03/06 08:12 11/03/06 09:27 11/06/06 10:43 11/03/06 09:03 QC1201219922 175288018 MS Carbon-14

-0.013

+/-0.127

+/-0.127 6.34

+/-0.319

+/-0.334 91 (75%-125%)

Batch 584649 QC1201219925 175288015 DUP Nickel-63 QC1201219927 LCS Nickel-63 QC1201219924 MB Nickel-63 QC1201219926 175288015 MS Nickel-63 U

-1.75 Uncert:

+/-9.40 TPU:

+/-9.40 U

5.23

+/-9.62

+/-9.62 pCi/g 0

(0% - 100%) V4XP1 508 Uncert:

TPU:

Uncert:

TPU:

562 U

Uncert:

TPU:

417

+/-19.6

+/-24.3 U

3.97

+/-9.36

+/-9.36 pCi/g pCi/g pCi/g 82 (75%-125%)

11/06/06 13:35 11/06/06 14:08 11/06/06 13:19 11/06/06 13:51

-1.75

+/-9.40

+/-9.40 432

+/-20.1

+/-25.4 77 (75%-125%)

Batch 584650 QC1201219929 175288015 DUP Iron-55 QC1201219931 LCS Iron-55 U

-20.5 Uncert:

+/-52.3 TPU:

+/-52.3 U

-20

+/-32.0

+/-32.0 pCi/g 0

(0% - 100%) VIXPI 11/03/06 16:18 11/03/06 16:51 587 Uncert:

TPU:

573

+/-46.4

+/-64.1 pCi/g 98 (75%-125%)

78

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

175288 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Liquid Scintillation Batch 584650 QC1201219928 MB Iron-55 QC1201219930 175288015 MS Iron-55 Uncert:

TPU:

U

-11.8

+/-27.9

+/-27.9 pCi/g pCi/g 11/03/06 16:02 11/03/06 16:34 632 U

Uncert:

TPU:

-20.5

+/-52.3

+/-52.3 Batch 585989 QC1201223382 175288015 DUP Tritium QC1201223384 LCS Tritium QC1201223381 MB Tritium QC1201223383 175288015 MS Tritium U

0.178 Uncert:

+/-0.744 TPU:

+/-0.744 U

610

+/-54.5

+/-74.9

-0.159

+/-0.801

+/-0.801 18.5

+/-3.05

+/-3.06 97 (75%-125%)

pCi/g 0

(0% - 100%) DFA1 20.2 Uncert:

TPU:

Uncert:

TPU:

21.2 U

Uncert:

TPU:

U 0.326

+/-0.728

+/-0.728 pCi/g pCi/g pCi/g 92 (75%-125%)

11/07/06 21:28 11/07/06 22:48 11/07/06 20:25 11/07/06 22:30 0.178

+/-0.744

+/-0.744 17.3

+/-3.22

+/-3.23 82 (75%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

U1 Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

175288 Page 9 of 9 Parmnane NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time A

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

80

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

Health Physics Procedure GPP-GGGR-R512 1 -001 Attachment B, Rev. CY-00 1 MAJOR Health Physics Procedure GPP-GGGR-R5121-001 Attachment B, Rev. CY-001 MAJOR Preliminary Data Review Form - Samples for the Sign Test Survey Unit:

9512- 0000 Survey Unit Name: Northwest Site Grounds Classification:

Survey Media:

Type of Survey:

Type of Measurement:

Number of Measurements:

Operational DCGL (pCi/g) 3 Soil Final Status Survey Radionuclide Specific 15 5.38E+00 BASIC STATISTICAL QUANTITIES Cs-137 Minimum Value:

-2.67E-03 Maximum Value:

6.12E-01 Mean:

2.OOE-01 Median:

1.60E-01 Standard Deviation:

2.06E-01 NUMBER 9512-0000-OOIF 9512-0000-002F 9512-0000-003F 9512-0000-004F 9512-0000-005F 9512-0000-006F 9512-0000-007F 9512-0000-009F 9512-0000-01OF 9512-0000-013F 9512-0000-014F 9512-0000-015F 9512-0000-017F 9512-0000-018F 9512-0000-019F RADIONUCLIDE CONCENTRATION (pCi/g)

Cs-137 Identified?

2.49E-01 Y

1.60E-01 N

3.32E-01 Y

3.05E-01 Y

6.12E-01 Y

3.64E-01 Y

5.80E-01 Y

2.28E-01 Y

-2.67E-03 Y

4.53E-02 N

6.72E-03 Y

1.35E-03 Y

6.83E-02 Y

1.93E-02 N

3.1 OE-02 N

Performed By:

Independent Review:

/4 e

Date:

,.1-Date:

21// 1)7

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

. Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium - 137 Survey Unit:

9512-0000 Survey Unit Name: Northwest Site Grounds Mean:

2.OOE-01 pCi/g 7.OOE-01 6.OOE-Q1 S5.OQE-O1 4.OOE-O1

~-

0= 3.00E-01--------------

tv 2.OOE-01 L-----------

0 1.OOE-O1--

O.OOE+O0

-i.OOE-O1 2- 0 T

4ec 6,

8O Percentage Cs-1 37 Rank Percentage

-2.67E-03 1

3 %

1.35E-03 2

10%

6.72E-03 3

17 %

1.93E-02 4

23 %

4.53E-02 5

30 %

6.83E-02 6

37 %

1.60E-01 7

43 %

2.28E-01 8

50 %

2.28E-01 9

57 %

2.49E-01 10 63 %

3.05E-01 11 70 %

3.32E-01 12 77 %

3.64E-01 13 83 %

5.80E-01 14 90 %

6.12E-01 15 97 %

Prepared By:,

  • (

/

Reviewed By:

.5 Date:

,/'4/49 Date:-

-n_?

Date:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cs - 137 Survey Unit:

9512-0000 Survey Unit Name: Northwest Site Grounds Mean:

0.200 pCi/g 14-12 -7 u_'

4--

2 0

0.00 0.25 0.50 0.75 1.00 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency 0.00 2

13%

0.25 12 80%

0.50 0

0%

0.75 1

7%

1.00 0

0%

Total 15 100%

Prepared By:

Date:

Reviewed By:,p, A

/1,rS5e i

1 D

Date:

(-ý) / / 3> Z ZýýOD 9-f

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Health Physics Procedure GPP-GGGR-R512 1-000 Attachment A, Rev. CY-001I MAJOR Health Physics Procedure GPP-GGGR-R5 12 1-000 Attachment A, Rev. CY-001 MAJOR Sign Test Calculation Sheet For Single Radionuclisde Survey Unit Number:

9512-0000 Survey Unit Name: Northwest Site Grounds WP&IR#: 2006-0038 Classification : 3

.TYPE I (CL error):0.05 (N) 15 Radionuclides: Cs-137 Survey Design DCGL (pCi/g): 5.38 Cs-137 Results Weighted Sum (W.)

DCGL-Result Sign

--- 1 01 46fE 02' 9.54E-01 1

1f6OE 01 3

9.69E-01 1

3.32 01 6 ME 02 9.39E-01 1

3.05 5

9.44E-01 6 1 13E701 8.87E-01 1

6. 7 4

E9.33E-01 1

ON PA. I M

8.93E-01 1

80 9.58E-01 1

12-6*7F,03

- 4EO,4%

1.00E+00 1

4.531-02 8.3 8E-01 9.92E-01 1

6.72E-03 1.24E-03 9.99E-01 I 135E'3 2.5QO4 1.00E+00 1

6.83E-021 26E 02 9.87E-01

  • ,K1.93*E*02 3.57E.03 9.96E-01 1

~3.1E702 5.70Eý03 K9.94E-01 1

Number of Positive Differences (S+):

15 Critical Value:

11 Survey Unit:

Meets Acceptance Criterion Performed By:

dd.49/

Date: _

/0____7 Independent Review:

j2.M Date:___

Page 1 of I

NORTHWEST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9512-0000 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area Survey 000Survey 9512 unit 0000 unNe:

Northwest Site Grounds Unit #:

Unit Name:

Sample Plan or WPIR#: 2006-038 SMIL #: 9512-0000-014FS Sample

Description:

Comparison of split samples collected from sample measurement location #14 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9512-0000-014F the comparison sample was 9512-0000-014FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137 6.72E-03 7.20E-03 I

NONE -

-9.13E-03 9.35E-03

-1.36 NA K-40 9.59E+00 2.50E-01 38 0.75-1.33 8.96E+00 3.94E-01 0.93 Y

Comments/Corrective Actions: In consideration of Cs-137 results, guidance for agreement ranges, obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations cannot be made. The agreement level for K-40 was found to be acceptable, no further actions are warranted.

Table is provided to show acceptance criteria used to assess split samples.

Resolution Agreement Range 4

8 16 51 7

15 50 200

> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Performed By:

WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I

Connecticut Yankee Decommissioning Project Health Physics. Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Survey Survey Unit Arey 9512 Unit 0000 Name:

Northwest Site Grounds Area#:

Unit #:

Name:

Sample Plan or WPIR#: 2006-0038 SML #: 9512-0000-017FS Sample

Description:

Comparison of split samples collected from sample measurement location #17 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9512-0000-017F, the comparison sample was 9512-0000-017FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137 6.83E-02 1.59E-02 4

0.5 2

5.98E-02 8.45E-03 0.88 Y

Comments/Corrective Actions: The agreement level for Cs-137 was found to be acceptable, no further actions are warranted.

Table is provided to show acceptance criteria used to assess split samples.

Resolution [

Agreement Range 4

8 16 51 7

15 50 200

> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Reviewed By: j?/7' l t Date:

WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation C)

Page I of 1