ML070320454
| ML070320454 | |
| Person / Time | |
|---|---|
| Site: | Yankee Rowe |
| Issue date: | 12/20/2006 |
| From: | John Hickman NRC/FSME/DWMEP/DURLD |
| To: | Carson A Yankee Atomic Electric Co |
| References | |
| Download: ML070320454 (2) | |
Text
LJohin Hikman - Summary Comments on Yankee Rowe 00L-12 & 00L-14 Final Status Survey Reports Page 1 From:
John Hickman To:
Yankee, Alice Carson Date:
12/20/2006 3:41:55 PM
Subject:
Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final Status Survey Reports
- Alice, My bad on these. Tom gave me these comments about a month ago and I lost track. Please address when you get a chance.
- Thanks, John, OOL-12 Observations/Comments:
FSS Report Appendix A - Final Status Survey Planning Worksheets - indicates that after a boundary modification, two bias samples that had been taken were considered to be outside the survey unit. This information is different from the information in Section 5.4 - Survey Results - which indicates that two samples (OOL-12-021 & OOL-12-022) were taken as bias samples & are not listed in the results table.
This situation could confuse some readers. Please clarify OOL-14 Observations/comments:
No information on gamma survey/scan results were provided in Section 5.4 - Survey Results or in Section 6.0 - Conclusions. OOL-1 4-01 is a class 3 soil area, and the Yankee Rowe LTP, Rev. 1, specifies judgmental gamma surveys/scans. It appears that some judgmental surveys were made, but the results are not given. Please address.
gjývým 6q mri-JI I c:\\temp\\GW}OOOO1.TMP Pag~
[
Mail Envelope Properties (4589A013.6CB : 12: 35218)
Subject:
Survey Reports Creation Date From:
Created By:
Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final Status 12/20/2006 3:41:55 PM John Hickman JBH@nrc.gov Recipients comcast.net PM acarson1967 (Yankee Alice Carson)
Action Transferred Date & Time 12/20/2006 3:42:10 Post Office Delivered Route comcast.net Files MESSAGE Options Auto Delete:
Expiration Date:
Notify Recipients:
Priority:
ReplyRequested:
Return Notification:
Send Notification when Opened Concealed
Subject:
Security:
To Be Delivered:
Status Tracking:
I Size 2059 Date & Time 12/20/2006 3:41:55 PM N4o None Yes Standard N4o Standard mmediate Delivered & Opened