Dominion Energy Kewaunee, Inc.

~1N10 l h n u n ~ o n Houlevard, (;lcn Allcn, VA 23060 October 3, 2006 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 b Dominion' Serial No.06-801 KPSILICIGR: RO Docket No.

50-305 License No. DPR-43 DOMINION ENERGY KEWAUNEE. INC.

KEWAUNEE POWER STATION 2004 INSERVICE INSPECTION

SUMMARY

REPORT CORRECTION On February 24, 2005, Kewaunee Power Station (KPS) submitted the KPS 2004 lnservice Inspection (ISI) Summary Report (ADAMS Accession No. ML050620242).

Subsequently, an error was discovered in a Form NIS-2, "Owners Report for RepairIReplacement Activity," which was included in the report. This Form NIS-2 is located in Enclosure 9 of the IS1 Summary Report and is labeled as Work Order number 04-008484.

The corrected Form NIS-2 is enclosed.

Dominion Energy Kewaunee, Inc. (DEK) requests the Form NIS-2 for Work Order 04-008484 submitted in the February 24, 2005 IS1 Summary Report be replaced with the enclosed corrected Form NIS-2.

DEK apologizes for any inconvenience this may cause.

If you have questions or require additional information, please feel free to contact Mr.

Gerald 0. Riste, at 920-388-8424.

Very truly yours, Gerald T. Bischof

(/

Vice President - Nuclear Engineering Enclosure - Corrected Form NIS-2 for Work Order 04-008484 Commitments made by this letter: None

Serial No.06-801 Page 2 of 2 cc:

Regional Administrator U. S. Nuclear Regulatory Commission Region Ill 2443 Warrenville Road Suite 21 0 Lisle, Illinois 60532-4352 Mr. D. H. Jaffe Project Manager U.S. Nuclear Regulatory Commission Mail Stop 0-7-D-1 Washington, D. C. 20555 Mr. S. C. Burton NRC Senior Resident Inspector Kewaunee Power Station

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Dominion Enerqv-Kewaunee N490 Hiqhwav 42, Kewaunee, Wisconsin 54216-951 1
2. Plant Kewaunee Power Station N490 Hiqhwav 42. Kewaunee, Wisconsin 54216-951 1
3. Work Performed By Dominion Eneruv-Kewaune N490 Hiqhwav 42, Kewaunee, Wisconsin 54216-951 1 Date 09/07/2006 Sheet 1 of 2 Unit Work Order 04-008484 Type Code Sym. Stamp NA Authorization No. NA 4, Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B16.34-SEC. 111-1982 (c) Applicable Section XI Code Case NA (b) Applicable Edition of Section XI Used for RepairlReplacement Activity 1998 Edition 2000 Addenda
6. ldentification of Components Corrected, ASME Name of Name of Manufacturer National Other Year Removed, or Code Component Manufacturer Serial No.

Board No.

ID Built Installed Stamped CVC-5C KEROTESTMFGCORP AJ 03-7 N A CSOO2-015 1986 INSTALLED N

7. Description of Work REPLACE CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE CVC-5C AND 6 - 2" SOCKET WELDS.
8. Tests conducted
9. Remarks Hydrostatic Pneumatic Nominal Operating Pressure Exempt Other Pressure 2235 psi Test Temp.

112 deg. F NIS-2 FORM IS A CORRECTED COPY PER KEWAUNEE CAP 036348. IN DESCRIPTION OF WORK CHANGED 2" VALVE CVC-5C AND 2 - 2" SOCKET WELDS TO 2" VALVE CVC-5C AND 6 - 2" SOCKET WELDS.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 09/07/2006 Name of Component: CVC-5C Work Order Number: 04-008484 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this INSTALLED conforms to the requirements of the ASME Code.Section XI.

Type Code Symbol Stamp NA Certificate of Authorization No.

Expiration Date P&~&ri,,-i+~.++~~-

Signed

~ate,&&d&

8 2 0 Qk Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Insurance Company of CT have inspected the components described in this Owner's Report during the period Y/%/L to ?/!/06, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the lnspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB 11622, I, N, B, A WIS 100131 National Board, State, Province, and Endorsements