Mid-Cycle Revision to the Core Operating Limits Report
ML062490404
Person / Time
Site: Perry FirstEnergy icon.png
Issue date: 08/28/2006
From: Pearce L
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PY-CEI/NRR-2987L
Download: ML062490404 (24)


Text

F'ENOC FirtEnergy Nuclear Operating Company Perry Nuclear Power Station 10 Center Road Perry, Ohio 44081 L. William Pearce tice President 440-280-5382 Fax: 440-280-8029 August 28, 2006 PY-CEI/NRR-2987L ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Perry Nuclear Power Plant Docket No. 50-440

Subject:

Mid-cycle Revision to the Core Operating Limits Report Enclosed is a mid-cycle revision to the Cycle 11 Core Operating Limits Report (COLR) for the Perry Nuclear Power Plant (PNPP). A description of the purpose of the revision is provided on page i of the Enclosure. This mid-cycle revision of the COLR is submitted in accordance with Technical Specification 5.6.5, "Core Operating Limits Report."

There are no regulatory commitments contained in this letter or its Enclosure. If there are any questions or if additional information is required, please contact Mr. Gregory A. Dunn, Manager-FENOC Fleet Licensing, at (330) 315-7243.

Sincry L. William Pearce Enclosure cc:

NRC Project Manager NRC Resident Inspector NRC Region III

ý00 ý

11 Enclosure PY-CEI/NRR-2987L Mid-Cycle Revision of the PNPP Core Operating Limits Report

PDB-F0001 Page:

i Rev. :

13 PERRY OPERATIONS MANUAL Plant Data Book Entry TITLE: CORE OPERATING LIMITS REPORT FOR THE PERRY NUCLEAR POWER PLANT UNIT 1 CYCLE 11 (RELOAD 10)

PDB F0001 /Rev.

13 MPL:

Jill EFFECTIVE DATE:

8-29-06

SUMMARY

OF LAST CHANGE:

Clarification of the administrative limit on MFLCPR during single loop operations.

REFERENCES:

Technical Specification 5.6.5, "Core Operating Limits Report" COMMITMENTS: None PREPARED BY:

J.

Meyer 7-11-06 Date

PDB-F0001 Page:

1 Rev.:

13 UNIT 1 CORE OPERATING LIMITS REPORT INDEX Specification Page INTRODUCTION AND REFERENCES 3 & 4 AVERAGE PLANAR LINEAR HEAT GENERATION RATE, APLHGR 5

(CORRESPONDS TO TS 3.2.1)

Figure 3.2.1-1 Flow Dependent MAPLHGR Factor (MAPFACf),

Fuel Types GEl4 6

Figure 3.2.1-2 Power Dependent MAPLHGR Factor (MAPFACp),

Fuel Types GE14 7

Figure 3.2.1-3 MAPLHGR Versus Average Planar Exposure, Fuel Type GEl4 8

MINIMUM CRITICAL POWER RATIO, MCPR (CORRESPONDS TO TS 3.2.2) 9 Figure 3.2.2-1 Power Dependent MCPR Limit (MCPRp),

Fuel Type GEl4 (Two Loop Operation) 11 Figure 3.2.2-2 Flow Dependent MCPR Limit (MCPRf),

Fuel Type GE14 (Two Loop Operation) 12 Figure 3.2.2-3 Power Dependent MCPR Limit (MCPRp),

Fuel Type GEl4 (Single Loop Operation).

13 Figure 3.2.2-4 Flow Dependent MCPR Limit (MCPRf),

Fuel Type GEl4 (Single Loop Operation) 14 Figure 3.2.2-5 Power Dependent MCPR Limit (MCPRP),

Fuel Type GEl4 (Two Loop Operation)

Pressure Regulator Out Of Service 15 Figure 3.2.2-6 Power Dependent MCPR Limit (MCPRp),

Fuel Type GEl4 (Single Loop Operation)

Pressure Regulator Out Of Service 16 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

2 Rev.:

13 UNIT 1 CORE OPERATING LIMITS REPORT INDEX (Continued)

Specification Figure 3.2.2-7 Page Maximum Fraction Limiting Critical Power Ratio Limit (MFLCPR),

Fuel Type GEl4 With One Pressure Regulator Out Of Service LINEAR HEAT GENERATION RATE, LHGR (CORRESPONDS TO TS 3.2.3)

Figure 3.2.3-1 LHGR Versus Average Planar Exposure, Fuel Type GE14 REACTOR PROTECTION SYSTEM INSTRUMENTATION (CORRESPONDS TO TS 3.3.1.1)

Simulated Thermal Power Time Constant OSCILLATION POWER RANGE MONITOR (OPRM)

INSTRUMENTATION (CORRESPONDS TO TS 3.3.1.3) 17 18 19 20 21 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

3 Rev.:

13 INTRODUCTION AND REFERENCES INTRODUCTION This Core Operating Limits Report for PNPP Unit 1 Cycle 11 is prepared in accordance with the requirements of PNPP Technical Specification Administrative Controls 5.6.5.

The core operating limits presented were developed using NRC-approved methods (Reference 2).

Results from the reload analysis for the General Electric fuel in PNPP Unit 1 for Cycle 11 are documented in References 3, 4 and 15.

The cycle-specific core operating limits for the following PNPP Unit 1 Technical Specifications are included in this report:

1. Average Planar Linear Heat Generation Rate (APLHGR) Limits for each fuel/lattice type, including the power and flow dependent MAPFAC curves with the single loop MAPLHGR reduction factor.

(Technical Specification 3.2.1)

2.

Minimum Critical Power Ratio Operating Limit including the power and flow dependent MCPR curves for Two Loop Operation and Single Loop Operation.

(Technical Specification 3.2.2)

Additional power dependent MCPR curves for Two Loop Operation and Single Loop Operation are provided for operation with one pressure regulator out of service.

3.

Linear Heat Generation Rate (LHGR) Limits for each fuel/lattice type, including the power and flow dependent MAPFAC curves with the single loop MAPLHGR reduction factor.

(Technical Specification 3.2.3)

4.

The simulated thermal power time constant.

(Technical Specification 3.3.1.1, SR 3.3.1.1.14)

5.

Oscillation Power Range Monitor (OPRM)

Instrumentation.

(Technical Specification 3.3.1.3)

REFERENCES

1.

Perry Nuclear Power Plant Updated Safety Analysis Report, Unit 1, Appendix 15B-Reload Safety Analysis.

2.

"General Electric Standard Application for Reactor Fuel-GESTAR II",

NEDE-24011-P-A-14 and NEDE-24011-P-A-14-US (US Supplement),

June 2000.

3.

"Supplemental Reload Licensing Report for Perry Nuclear Power Plant Unit 1 Reload I0 Cycle 11", GNF Document 0000-0028-4692SRLR, Rev 1, March 2005.

PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

4 Rev.:

13

4.

"Fuel Bundle Information Report for Perry Nuclear Power Plant Unit 1 Reload 10 Cycle 11", GNF Document 0000-0028-4692FBIR, Rev 0, December 2004.

5.

License Amendment No.

61 to Facility Operating License NPF - 58, June 2, 1994.

6.

Generic Letter 88-16, "REMOVAL OF CYCLE-SPECIFIC PARAMETERS FROM TECHNICAL SPECIFICATIONS".

7.

Technical Specification 3.2.1, Average Planar Linear Heat Generation Rate.

8.

Technical Specification 3.2.2, Minimum Critical Power Ratio.

9.

Technical Specification 3.2.3, Linear Heat Generation Rate.

10. Technical Specification 3.3.1.1, Reactor Protection System Instrumentation.
11. Technical Specification 5.6.5, Core Operating Limits Report.
12.

Technical Specification 2.1.1.2, Safety Limit MCPR.

13.

License Amendment No.

33 to Facility Operating License NPF - 58, September 13, 1990.

14.

License Amendment 112 to Facility Operating License NPF-58, June 1, 2000.

15.

"Supplemental Reload Licensing Report'for Perry Nuclear Power Plant Unit 1 Reload 8 Cycle 9",

GNF Document Jll-03754SRLR, Rev 1, January 2003.

16.

CR 03-01377, "Equation for OL MCPR(P) in the Core Operating Limits Report is Suspect."

17.

License Amendment 132, Perry Nuclear Power Plant, Unit 1 - Issuance of Amendment RE: Revision of the Minimum Critical Power Ratio Safety Limit (TAC No.

MC 2599),

February 3, 2005.

18.

License Amendment 134, Perry Nuclear Power Plant, Unit 1 - Issuance of Amendment RE: Single Recirculation Loop Operation (TAC No.

MC 4224),

March 31, 2005.

19.

Calculation FM-012, OPRM Device Settings and Setpoints, Revision 1, Addendum A-01.

PERRY UNIT I CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-FO001 Page:

5 Rev.:

13 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (TS 3.2.1)

All AVERAGE PLANAR LINEAR HEAT GENERATION RATES (APLHGRs) shall not exceed the result obtained from multiplying the applicable MAPLHGR limits* by the smaller of either the flow dependent MAPLHGR factor (MAPFACf)

Figure 3.2.1-1 or the power dependent MAPLHGR factor (MAPFACp) Figure 3.2.1-2.

The following table lists the MAPLHGR limits as a function of exposure for GE14 fuel:

Exposure (GWD/st)

ECCS MAPLHGR Limit (KW/FT) 0.00 12.82 14.51 12.82 19.13 12.82 57.61 8.00 63.50 5.00 NOTE:

MAPLHGR Limits are defined in Reference 3.

MAPFACf and MAPFACp are defined in Reference 15.

NOTE:

The Single Loop Operation limits take effect when reset for single loop operation per LCO 3.4.1,"Recirculation Loops Operating".

This is consistent with note "(b)"

to Table 3.3.1.1-1 of the Technical Specifications.

Use FTI-B0012 Single Loop Operation to implement the revised MAPLHGR Limits.

These applicable MAPLHGR limits are:

1. Those for the respective fuel as a function of the average planar exposure (as described by the NRC approved methodology described in GESTAR-II) or,
2.

When hand calculations are required, the MAPLHGR limit as a function of the average planar exposure as shown in Figures 3.2.1-3 (GEl4).

PERRY UNIT 1 CYCLE II CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

6 Rev.:

13 Flow Dependent RAPLHGR Factor (MAPFACf),

Fuel TvYe GE14 1.1 1.0 0.9

',-C.,

~0.8 0.7 0.6 0.5 GE14 - Clamped at 0.80 During SLO MAPFACf-MIN(1.0,0.4574+0.006758F) 0 20 40 60 80 100 120 CORE FLOW (% RATED)

Figure 3.2.1-1 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

7 Rev.:

13 Power DeDendent MAPLHGR Factor (MAPFAC,),

Fuel Tvpes GEl4 1.9 0.0 0.9 0.

0.6 0.5 0/

MAPFACp=1.0+0.0052(iOF10 38%<P<=100%; All core flows 4

23.8%<=P<=38%; Core Flow <=-50%

4 - Clamped at urn SSLO or of I

MAPFACp=0.6+0.0021(P-38) 23.8%<=P<--38%; Core Flow >50%

,F

,I*

-I.

I.

0 20 40 60 80 100 CORE THERMAL POWER (% RATED)

Figure 3.2.1-2 PERRY UNIT 1 CYCLE II CORE OPERATING LIMITS REPORT

PDB-FO001 Page:

8 Rev.:

13 MAPLHGR Versus Average Planar Exposure, Fuel Type GEl4 14 12 10 LL 4-J U.)

wU 8

6 4

2 0

NOTE:

0 5

10 15 20 25 30 35 40 45 50 55 60 65 70 Average Planar Exposure (GWDIST)

1. Intermediate MAPLHGR values are obtained by linear interpolation between adjacent points.

Figure 3.2.1-3 PERRY UNIT 1 CYCLE II CORE OPERATING LIMITS REPORT

PDB-FO001 Page:

9 Rev.:

13 MINIMUM CRITICAL POWER RATIO (TS 3.2.2)

The MINIMUM CRITICAL POWER RATIO (MCPR) shall be equal to or greater than the higher of the MCPRf and MCPR, limits at the indicated core flow and THERMAL POWER as specified in Figures 3.2.2-1 and 3.2.2-2 for Two Loop Operation and Figures 3.2.2-3 and 3.2.2-4 for Single Loop Operation.

The MCPR Safety Limit for Cycle 11 is 1.08 and the MCPR Safety Limit for Single Loop Operation is 1.10 <TECHNICAL SPECIFICATIONS 2.1.1.2> (Reference 3 and 17).

During Single Loop Operation with 3D MONICORE monitor in "2 LOOPS ON" mode, the Maximum Fraction of Limiting Critical Power Ratio (MFLCPR) shall be equal to or less than 0.98.

Use FTI-B0012 Single Loop Operation to implement this revised MFLCPR.

NOTE 1:

For Cycle 11 no change to MCPR limits is required for planned reduction of feedwater temperature to as low as 325.5 0F.

Final feedwater temperature may be reduced to 255.5*F after all control rods are withdrawn at the end of cycle if the OPRMs are OPERABLE.

NOTE 2:

Planned reduction of rated feedwater temperature from nominal rated feedwater temperature is not permitted during plant operation with the reactor recirculation system in Single Loop Operation, if the OPRMs are operable.

NOTE 3:

Figures 3.2.2-1 and 3.2.2-2 depict the limiting fuel type for Two Loop Operation.

Figures 3.2.2-3 and 3.2.2-4 depict the limiting fuel type for Single Loop operation.

Specific values are found in References 3 and 15.

Figures 3.2.2-5 and 3.2.2-6 depict power dependent MCPR curves for Two Loop Operation and Single Loop Operation for operation with one pressure regulator out of service.

This may be implemented as either a change to the core monitoring software or appropriate administrative limit.

Figure 3.2.2-7 depicts implementing an administrative limit to the Maximum Fraction Limiting Critical Power Ratio with One Pressure Regulator Out Of Service.

In the case where a Pressure Regulator is out of service and the plant is in Single Loop Operations, limit MFLCPR to the smaller of 0.98 and Figure 3.2.2-7, MFLCPR Limit With One Pressure Regulator Out Of Service.

NOTE 4:

There are a total of 19 safety/relief valves, the two lowest setpoint valves are assumed to be out-of-service in the transient analysis.

NOTE 5:

The MCPR operating limit is increased 0.02 to account for the increase in the single loop MCPR safety limit with the reactor recirculation system in Single Loop Operation.

PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

10 Rev.:

13 NOTE 6:

The Single Loop Operation limits take effect when reset for Single Loop Operation per LCO 3.4.1, "Recirculation Loops Operating".

This is consistent with note "(b)"

to Table 3.3.1.1-1 of the Technical Specifications.

NOTE 7:

The standard off-rated limits established as part of the GEl4 new fuel introduction from Cycle 9 are applicable for the current Cycle 11 with the appropriate scaling.

The SLMCPR basis for MCPR(P) limits below Pbypass for GEl4 is 1.10, and the MCPR(F) coefficients are based on a SLMCPR of 1.07.

Therefore, scaling of (1.08/1.10) was applied to the MCPR(P) graphs and scaling of (1.08/1.07) is applied to MCPR(F) coefficients to account for the changes in the SLMCPR (Reference 3).

PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

11 Rev.:

13 Power Dependent MCPR Limit (MCPRp),

Fuel Type GE14 (Two Loop Operation)*

0 Ix 0

00 0.

o0

-j 0

0.

0 20 40 60 80 CORE THERMAL POWER (% RATED) 100

  • Refer to NOTE 3 on Page 9 Figure 3.2.2-1 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

12 Rev.:

13 Flow Dependent MCPR Limit (MCPRf),

Fuel Type GE14 (Two Loop Operation)*

1.8 1.7 c

~1.6 Q

0 0

_1 01.5 U

1.4 1.3 1.2 0

20 40 60 80 100 120 CORE FLOW (% RATED)

  • Refer to NOTE 3 on Page 9 and Note 7 on Page 10 Figure 3.2.2-2 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-FO001 Page:

13 Rev.:

13 Power Dependent MCPR Limit (MCPR)),

Fuel Type GEl4 (Single Loop Operation)*

.2 0

0.

0 cm C,,

w.

0 20 40 60 80 CORE THERMAL POWER (% RATED)

  • Refer to NOTE 3 and NOTE 5 on Page 9 Figure 3.2.2-3 100 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

14 Rev.:

13 Flow Dependent MCPR Limit (MCPRf),

Fuel Type GEl4 (Single Loop Operation)*

1.8 1.

0 0

3.

2 1.4 1.3 1.2 0

20 40 60 80 100 120 CORE FLOW (% RATED)

  • Refer to NOTE 3 and NOTE 5 on Page 9 and Note 7 on Page 10.

Figure 3.2.2-4 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-FO001 Page:

15 Rev.:

13 Power Dependent MCPR Limit (MCPRp),

Fuel Type GE14 (Two Loop Operation)*

Pressure Regulator Out Of Service 2.5 2.4 2.3 2.2 "2.1 00 C

2.0 0

0 1.9 CL 0

00 1.8

-j 0

-~1.7 C.

W.,

~1.6 1.5 1.4 1.3 1.2 0

20 40 60 80 CORE THERMAL POWER (% RATED) 100

  • Refer to NOTE 3 on Page 9 Figure 3.2.2-5 PERRY UNIT 1 CYCLE II CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

16 Rev.:

13 Power Dependent MCPR Limit (MCPRp),

Fuel Type GE14 (Single Loop Operation)*

Pressure Regulator Out Of Service 2.5 2A 2.3 2.2

/

2.1 0

0,w W

62.0 0

CL 1.9 0

0 0

_ 1.8 CO 1.7 0.

1.5 1.4 1.3 1.2 0

20 40 60 80 CORE THERMAL POWER (% RATED)

  • Refer to NOTE 3 and NOTE 5 on Page 9 Figure 3.2.2-6 100 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Rev. :

13 Page:

17 Maximum Fraction Limiting Critical Power Ratio Limit (MFLCPR),

Fuel Type GEl4 With One Pre~~ure PecniTht-or Out Of Service MFLCPR Limit With One Pressure Regulator Out Of Service 1.010 1.005 1.000 0.995 0.990 0.985 0.980 0.975 0.970 0.965 0.960 0.955 0.950 S0.945 0

0.940

-J 0.935

.~0.930 0.925 0.920

.s 0.915 0.910 0.905 0.900 0.895 0.890 0.885 0.880 0.875 0.870 0.865 0.860 0.855 0.850 Single Loop--

Operating Limit Z I+/- d Unsafe-

~~~~~~I--------------

-fl---1~--------------------------

R I

V I

?A 80%.

RTP 38% RTP Sf I...,-

20 25 30 35 40 45 50 55 60 65 70 75 80 85

% Reactor Thermal Power 90 95 100

  • Refer to NOTE 3 and NOTE 5 on Page 9 Figure 3.2.2-7 PERRY UNIT 1 CYCLE 11 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

18 Rev.:

13 LINEAR HEAT GENERATION RATE (TS 3.2.3)

All LINEAR HEAT GENERATION RATES (LHGRs) shall not exceed the result obtained from multiplying the applicable LHGR values* by the smaller of either the flow dependent MAPLHGR factor (MAPFACf)

Figure 3.2.1-1 or the power dependent MAPLHGR factor (MAPFAC.) Figure 3.2.1-2.

NOTE:

LHGR Limits are defined in Reference 4.

MAPFACf and MAPFACp are defined in Reference 15.

NOTE:

The Single Loop Operation limits take effect when reset for single loop operation per LCO 3.4.1,"Recirculation Loops Operating".

This is consistent with note "(b)"

to Table 3.3.1.1-1 of the Technical Specifications.

Use FTI-B0012 Single Loop Operation to implement the revised LHGR Limits.

These applicable LHGR values are:

1.

Those for the respective fuel type and Gadolinium content as a function of the average planar exposure (as described by the NRC approved methodology described in GESTAR-II) or,

2.

When hand calculations are required, the LHGR as a function of the average planar exposure shown in Figures 3.2.3-1 (GE14).

PERRY UNIT I

PDB-FO001 Page:

19 Rev.:

13 LHGR Versus Average Planar Exposure, Fuel Type GEl4 16 14 12 10

-J 8

U02 LHGR Limi LHGR =13.4 for Exposures </= 14.51 LHGR z 13.4 + {.0.12529)*(Exposure - 14.51) for 14.51 < Exposures </= 57.61 LHGR =8.0 + (.0.50934)*(Exposure -.57.61) for 57.61 < Exposures </= 63.5 UO2IGd LHGR UmIt LHGR 12.00 for Exposures <1= 12.17 LHGR =12.00 + (.0.11410)*(Expasure -12.17) for 12.17 < Exposures </= 54.59 LHGR =:7.16 + (.0.46207)*(Exposure -.54.59) for 54.59 < Exposures </= 60.39

. A. A A *A

- A 6

4 2

0 0

5 10 15 20 25 30 35 40 45 50 55 60 I

Peak Pellet Exposure (GWD/ST) 65 70 NOTE:

1. Intermediate LHGR values are obtained by linear interpolation between adjacent points.

Figure 3.2.3-1 PERRY UNIT 1

PDB-FO001 Page:

20 Rev.:

13 REACTOR PROTECTION SYSTEM INSTRUMENTATION (TS 3.3.1.1)

The simulated thermal power time constant shall be 6+/-0.6 seconds.

PERRY UNIT 1

PDB-FO001 Page:

21 -

LAST Rev.:

13 OSCILLATION POWER RANGE MONITOR (OPRM)

INSTRUMENTATION (TS 3.3.1.3)

These are the Cycle 11 OPRM setpoints for operable OPRMs.

Current Settings:

1. Confirmation Count Setpoint (Np = N2):

10

2.

Amplitude Setpoint (Sp):

1.07

Reference:

Calculation:

FM-012, Revision 1, Addendum A-01 PERRY UNIT I CYCLE 11 CORE OPERATING LIMITS REPORT