ML062490037

From kanterella
Jump to navigation Jump to search

Technical Specifications, Application of the Alternative Source Term for Reevaluation of the Fuel Handling Accident Dose Consequences and Related Technical Specification Changes, MC8566
ML062490037
Person / Time
Site: Cooper Entergy icon.png
Issue date: 09/05/2006
From:
NRC/NRR/ADRO/DORL/LPLIV
To:
Benney B, NRR/DLPM, 415-3764
Shared Package
ML062260229 List:
References
TAC MC8566
Download: ML062490037 (11)


Text

Secondary Containment Isolation Instrumentation 3.3.6.2 Table 3.3.6.2-1 (page 1 of 1)

Secondary Containment Isolation Instrumentation APPLICABLE MODES OR REQUIRED OTHER CHANNELS SPECIFIED PER SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS TRIP SYSTEM REQUIREMENTS VALUE

1.

Reaclor Vessel Water 1.2,3, 2

SR 3.3.6.2.1

->- 42 inches Level - Low Low (Level 2)

(a)

SR 3.3.6.2.2 SR 3.3.6.2.3 SR 3.3.6.2.4

2.

Drywv.Il Pressure - High 1,2.3 2

SR 3.3.6.2.2

< 1.84 psig SR 3.3.6.2.3 SR 3.3.6.2.4

3.

Reactor Building Ventilation 1,2.3, 2

SR 3.3.6.2.1

<49mRfhr Exhaust Plenum (a),(b)

SR. 3.3.6.2.2 Radiation - High SR 3.3.6.2.3 SR 3.3.6.2.4 (a)

(b)

During operations with a potential for draining the reactor vessel.

During movement of recently Irradiated fuel assemblies In secondary containment.

I Amendment 222_..3_5 3.3-57

CREF System Instrumentation 3.3.7.1 Table 3.3.7.1-1 (page I of 1)

Control Room Emergency Filter System Instrumentation APPLICABLE MODES OR REQUIRED OTHER CHANNELS SPECIFIED PER TRIP SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM REQUIREMENTS VALUE

1. Reactor Vessel Water 1.2,3, 2

SR 3.3.7.1.1

>-421nches L,3vel - Low Low (Level 2)

(a)

SR 3.3.7.1.2 SR 3.3.7.1.3 SR 3.3.7.1.4

2. Drywell Pressure - High 1,2.3 2

SR 3.3.7.1.2

< 1.84 pslg SR 3.3.7.1.3 SR 3.3.7.1.4

3. Reactor Building Ventilation 1.2.3.

2 SR 3.3.7.1.1 S 49 mRPhr Exhaust Plenum (a),(b)

SR 3.3.7.1.2 Radiation - High SR 3.3.7.1.3 SR 3.3.7.1.4 (a)

Duwing operations wIth a potential for draining the reactor vessel.

(b)

Duitng movement of lately Irradiated fuel assemblies In the secondary containment I

Cooper 3.3-63 Amendment 2 22

Secondary Containment 3.6.4.1 3.6 CONTAINMENT SYSTEMS 3.6.4.1 Secondary Containment LCO 3.6.4.1 The secondary containment shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3, During movement of recently irradiated fuel assemblies in the secondary containment, During operations with a potential for draining the reactor vessel (OPDRVs).

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Secondary containment A.1 Restore secondary 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Inoperable in MODE 1, 2, containment to or 3.

OPERABLE status.

B.

Required Action and B.1 Be In MODE 3.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time of Condition A not AND met.

B.2 Be In MODE 4.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> C.

Secondary containment C.1 NOTE inoperable during LCO 3.0.3 Is not movement of recently applicable.

irradiated fuel assemblies in the secondary containment or during Suspend movement of Immediately OPDRVs.

recently Irradiated fuel assemblies In the secondary containment.

'AND (continued)

I Cooper 3.6-32 Amendment 2 2.2

Secondary Containment 3.6.4.1 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME C.

(continued)

C.2 Initiate action to suspend Immediately OPDRVs.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.6.4.1.1 Verify secondary containment vacuum is.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />

> 0.25 inch of vacuum water gauge.

SR 3.6.4.1.2 Verify all secondary containment equipment 31 days hatches are closed and sealed.

SR 3.6.4.1.3 Verify one secondary containment access door in 31 days each access opening Is closed.

SR 3.6.4.1.4 Verify each SGT subsystem can maintain 18 months on a

> 0.25 inch of vacuum water gauge in the STAGGERED secondary containment for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at a flow rate TEST BASIS

<1780 cfm.

I Cooper 3.6-33 Amendment 2 2_2

SCIVs 3.6.4.2 3.6 CONTAINMENT SYSTEMS 3.6.4.2 Secondary Containment Isolation Valves (SCIVs)

LCO 3.6.4.2 APPLICABILITY:

Each SCIV shall be OPERABLE.

MODES 1. 2, and 3, During movement of recently irradiated fuel assemblies In the secondary containment, During operations with a potential for draining the reactor vessel (OPDRVs).

I ACTIONS NOTES

1.

Penetration flow paths may be unisolated Intermittently under administrative controls.

2.

Separate Condition entry is allowed for each penetration flow path.

3.

Enter applicable Conditions and Required Actions for systems made Inoperable by SCIVs.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more penetration A.1 Isolate the affected 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> flow paths with one SCIV penetration flow path by inoperable, use of at least one dosed and de-activated automatic valve, dosed manual valve, or blind flange.

AND (continued)

Cooper 3.6-34 Amendment 222

SCIVs 3.6.4.2 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME D.

Required Action and D.1

-NOTE associated Completion LCO 3.0.3 is not Time of Condition A or B applicable.

not met during movement of recently irradiated fuel assemblies in the Suspend movement of Immediately secondary containment or recently Irradiated fuel during OPDRVs.

assemblies In the secondary containment.

AND D.2 Initiate action to suspend Immediately OPDRVs.

I I

Cooper 3.6-36 Amendment No. 2 2.2

SGT System 3.6.4.3 3.6 CONTAINMENT SYSTEMS 3.6.4.3 Standby Gas Treatment (SGT) System LCO 3.6.4.3 APPLICABILITY:

Two SGT subsystems shall be OPERABLE.

MODES 1,.2, and 3, During movement of recently irradiated fuel assemblies In the secondary containment, During operations with a potential for draining the reactor vessel (OPDRVs).

I ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One SGT subsystem A.1 Restore SGT subsystem 7 days Inoperable.

to OPERABLE status.

B.

Required Action and B.1 Be In MODE 3.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time of Condition A not AND met In MODE 1, 2, or 3.

B.2 Be In MODE 4.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> C.

Required Action and NOTE associated Completion LCO 3.0.3 is not applicable.

Time of Condition A not met during movement of recently Irradiated fuel C.1 Place OPERABLE SGT Immediately assemblies In the subsystem in operation.

secondary containment or during OPDRVs.

OR (continued)

I Cooper 3.6-38 Amendment No. 2 2.2

SGT System 3.6.4.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME C.

(continued)

C.2.1 Suspend movement of Immediately recently Irradiated fuel assemblies in secondary containment.

AND C.2.2 Initiate action to Immediately suspend OPDRVs.

D. Two SGT subsystems D.1 Enter LCO 3.0.3 Immediately Inoperable In MODE I 2, or 3.

E. Two SGT subsystems E.1 NOTE-Inoperable during LCO 3.0.3 Is not movement of recently applicable.

Irradiated fuel assemblies In the secondary Suspend movement of Immediately containment or recently irradiated fuel during OPDRVs.

assemblies In secondary containment.

AND (continued) 1 I

I Cooper 3.6-39 Amendment No. 222-

SGT System 3.6.4.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME E. (continued)

E.2 Initiate action to Immediately suspend OPDRVs.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.6.4.3.1 Operate each SGT subsystem for 10 continuous 31 days hours with heaters operating.

SR 3.6.4.3.2 Perform required SGT filter testing in accordance In accordance with the Ventilation Filter Testing Program (VFTP).

with the VFTP SR 3.6.4.3.3 Verify each SGT subsystem actuates on an actual 18 months or simulated initiation signal.

SR 3.6.4.3.4 Verify the SGT units cross tie damper is in the 18 months correct position, and each SGT room air supply check valve and SGT dilution air shutoff valve can be opened.

Amendment 2 22 3..2 3.6-40

CREF System 3.7.4 3.7 PLANT SYSTEMS 3.7.4 Control Room Emergency Filter (CREF) System LCO 3.7.4 The CREF System shall be OPERABLE.

APPLICABILITY: MODES 1, 2, and 3, During movement of lately irradiated fuel assemblies in the secondary containment, During operations with a potential for draining the reactor vessel (OPDRVs).

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

CREF System inoperable.

A.1 Restore CREF System to 7 days OPERABLE status.

B.

Required Action and B.1 Be in MODE 3.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time of Condition A not AND met in MODE 1, 2, or 3.

B.2 Be in MODE 4.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> (continued)

I Cooper 3.7-8 Amendment No..2.2

CREF Systerm 3.7.4 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C.

Required Action and NOTE.-O associated Completion LCO 3.0.3 is not applicable.

Time of Condition A not met during movement of lately irradiated fuel C.1 Suspend movement of lately Immediately assemblies In the irradiated fuel assemblies In secondary containment or the secondary containment.

during OPDRVs.

AN..DD C.2 Initiate action to Immediately suspend OPDRVs.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.4.1 Operate the CREF System for> 15 minutes.

31 days (continued)

Cooper-3.7-9 Amendment No. "7-e7, 2 2 2