ML062400461

From kanterella
Jump to navigation Jump to search
Drawing 25212-26902, Rev 16 and 12179-EM-102F, Piping & Instrumentation Diagram, Reactor Coolant System. Sheet 6 of 6
ML062400461
Person / Time
Site: Millstone Dominion icon.png
Issue date: 11/07/2005
From:
Dominion, Dominion Nuclear Connecticut, Stone & Webster Engineering Corp
To:
Office of Nuclear Reactor Regulation
References
12179-EM-102F, 25212-26902, Rev 16
Download: ML062400461 (1)


Text

REACTOR PLANT GASEOUS DRAINS 3-DGS-004-274-4 X

X X

X X

X X

X X

S NITROGEN SUPPLY EM-139B J-11 26939 SH 2 REACTOR PLANT SAMPLING EM-144B B-2 26944 SH 2 3-GSN-750-70-4 V192 8047 3-RCS-750-94-4 V193 8011 CL 152 CL 151 3-SSR-375-23-4 3-RCS-750-96-4 V194 8092 V199 8048 V

3-RCS-750-100-4 3-RCS-750-100-4 RUPTURE DISCS PSE 37 PSE 38 FC V195 PCV 469 FO A/S HS MB4 I

PRIMARY GRADE WATER 3-PGS-003-41-4 REACTOR PLANT GASEOUS DRAINS 3-RCS-750-101-4 PAH MB4 469 PT 469 C

V196 8049A SOV 469 LT 470 V197 8049B 2

26904 SH 1 3-CHS-001-525-4 TI 125 MB3 TAH 468 TI C

TE 468 3-RCS-004-90-4 TE 125 CHEMICAL &

VOLUME CONTROL EM-112A D-3 26904 SH 1 3-RCS-004-91-4 3-RCS-006-97-4 3-RCS-006-111-4 26912 SH 1 3-RCS-001-218-4 NOTE 13 EM-112A A-4 26912 SH 1 CL 1502 CL 153 NOTE 13 3-RCS-001-219-4 3-RCS-012-78-4 S

D D

V EM-103A G-1 26903 SH 1 REAC COOLANT PUMP SEALS M

IMB C

HS HS ASP MB3 I

S S

S S

FC FC C

C I

I HS HS ASP ASP MB3 MB3 I

I HS HS HS ASP MB3 MB3 C

C FC FC S

3-RCS-001-232-2(Z-)

FG 47 3-RCS-001-233-4 FC FC 442B 442B1 (ZP)

(ZP)

(ZP)

(ZP) 442B 442B1 3-RCS-001-234-2(Z-)

LI 470 C

S FO FC SV 8037A HS MB4 A/S 3-RCS-002-127-1(A-)

8039A 3-RCS-750-180-2(A-)

3-SSR-375-11-2(A-)

3-RCS-002-172-1(A-)

EM-144B G-2 26944 SH 2 REACTOR PLANT SAMPLING 3-RCS-002-126-1(A-)

LC 8040A 3-RCS-002-173-1(A-)

S FO FC HS MB4 A/S LC EM-144B E-2 26944 SH 2 REACTOR PLANT SAMPLING 3-SSR-375-12-2(B-)

3-RCS-750-181-2(B-)

8039B 3-RCS-002-130-1(B-)

SV 8037B 3-RCS-002-174-1(B-)

3-RCS-002-175-1(B-)

8040B 3-RCS-002-129-1(B-)

IMB OMB S

FO FC HS MB4 A/S LC 3-RCS-002-135-1(C-)

8039C 8040C SV 8037C 3-RCS-750-182-2(C-)

3-RCS-002-176-1(C-)

REACTOR PLANT SAMPLING EM-144B F-2 26944 SH 2 3-SSR-375-13-2(C-)

3-RCS-002-134-1(C-)

3-RCS-002-177-1(C-)

S FO FC HS MB4 A/S LC 3-RCS-002-143-1(D-)

8039D 3-RCS-750-183-2(D-)

SV 8037D 3-RCS-002-178-1(D-)

REACTOR PLANT SAMPLING EM-144B F-2 26944 SH 2 3-SSR-375-14-2(D-)

3-RCS-002-142-1(D-)

8040D 3-RCS-002-179-1(D-)

EM-103A F-2 26903 SH 1 S

FO FC HS A/S 3-CHS-001-269-2(Z-)

MB3 C

3-RCS-750-216-2(Z-)

3-RCS-750-217-2(Z-)

V 3-RCS-001-113-1(Z-)

3-RCS-750-215-2(Z-)

D 3-RCS-002-148-1(Z-)

REACTOR PLANT GASEOUS DRAINS 3-DGS-002-19-4 8350 LC CL 1502 CL 152 NOTES:

1.

REACTOR COOLANT SYSTEM 71-156 EM-107A I-7 EM-104A B-8 EM-104A I-2 26904 SH 1 26912 SH 1 EM-107A M-4 FOR GENERAL NOTES AND REFERENCE DRAWINGS SEE EM-102A (26902 SH 1).

REACTOR COOLANT PUMP SEAL NOTE 13 EM-107A G-2

  • V943(Z-)
  • V944(Z-)
  • V954(Z-)
  • V940(Z-)

8096B (ZP)

ASP TAH MB3 TI 400 PI MB4 3DGS*SV8031 EM-107A J-7 TAH MB4 CHEMICAL &

VOLUME CONTROL EM-104A B-8 LP SAFETY INJECTION LP SAFETY INJECTION LP SAFETY INJECTION LP SAFETY INJECTION CHEMICAL &

VOLUME CONTROL SH SH 3-CHS-025-304-2(Z-)

3-RHS-750-45-2(A-)

3-RHS-750-46-2(B-)

OMB C

MB3 ASP 3-RCS-001-228-2(Z-)

MB3 (Z0)

(Z0)

(Z0)

(Z0) 442A1 442A1 HS HS (Z0)

I 442A2 FTSP MB3 MB3 ASP ASP 442A 442A MB4 MB3 MB4 MB4 Q.A.

26912 SH 1 CL 1502 CL 153 CL 1502 CL ICN-9 CL 1502 CL ICN-9 CL 1502 CL ICN-9 CL 1502 CL ICN-9 1"

CL ICN-9 CL 152 CL 1502 CL 602 EM-112A A-5 EM-112A E-2 HS LOCAL/

REMOTE TSPB A

HS HS TSPB LOCAL/

REMOTE HS HS A

LOCAL/

REMOTE LOCAL/

REMOTE TSPA TSPA HS LOCAL/

REMOTE TSPA A

I I

TSPA A

LOCAL/

REMOTE MB3 LOCAL CONT ISOLATE/

REMOTE ASP EM-102C K-1 HI PRESS CLOSE PCV LAL LAH LAHH HI LVL EM-102A A-5 EM-102A G-3 26902 SH 1 26902 SH 1 EM-102D G-2 26902 SH 4 26902 SH 4 EM-102B K-7 EM-102B F-2 26902 SH 2 26902 SH 2 EM-102E J-10 EM-102E F-2 26902 SH 5 26902 SH 5 26919 SH 1 MB3 LOCAL CONT MB3 LOCAL CONT MB3 LOCAL CONTROL EM-119A H-3 EM-102D A-4 SEB/SBR 2-2-88 3-RCS-750-214-1(Z-)

26907 26907 A

MB3 LOCAL CONTROL REACTOR COOLANT SYSTEM 3-RCS-001-231-4 26902 SH 3 26907 26907 RSH GMO 2-11-88 FJL 2-11-88 2-11-88 DJR DAS

  • SV 8095B (ZP)
  • SV 8095A (ZO)
  • SV 8096A (ZO)
  • MV 8098 (ZO)
  • HIC
  • ZI
  • HC
  • HC
  • ZI
  • HCV 442B (ZP)
  • ZT 442B (ZP)
  • HC
  • ZI
  • ZI
  • HC
  • V941(Z-)
  • V942(Z-)
  • V959(Z-)
  • SV
  • V963(Z-)
  • V962(Z-)
  • V964(Z-)
  • V965(Z-)
  • V960(Z-)
  • V961(Z-)
  • V957(Z-)

442A (ZO) 442A (ZO)

  • ZT
  • HCV
  • V202(A-)
  • V999(A-)
  • V205(B-)
  • V998(B-)
  • V204(B-)
  • V203(A-)
  • V201(A-)

8037A (A-)

8037B (B-)

  • AV
  • AV
  • V206(B-)
  • V207(C-)
  • V208(C-)
  • V997(C-)
  • V209(C-)
  • V210(D-)

8037C (C-)

8037D (D-)

  • AV
  • AV
  • V212(D-)
  • V996(D-)
  • V211(D-)
  • V994(Z-)
  • V995(Z-)
  • V213(Z-)

8153 (ZP) 8153 (ZP)

  • SV
  • AV
  • V198(Z-)

NUCLEAR SAFETY RELATED QA CAT. I, I I NO.

DATE REVISIONS BY CHK.

APP.

MF CORR P.A.#

2.

102F

  • V899(Z-)

3-RCS-001-247-1(Z-)

3-RCS-001-246-1(Z-)

3-RCS-001-245-1(Z-)

SET @

1500 PSI CL. 152 CL. 1502 EM-103A N-1 26903 3-RCS-001-250-4

  • V955(Z-)
  • V2000(Z-)

CL ICN-9 3-RCS-001-227-1(Z-)

LC

  • V898(Z-)

LC REACTOR COOLANT PRESSURIZER RELIEF TANK 3RCS-TK2

  • V896(Z-)

LO

  • V895(Z-)

LO LO

  • V897(Z-)

3-RCS-001-230-2(Z-)

NOTE 3 (EM-102F)

3. RUPTURE DISCS, 3RCS-PSE37 AND 3RCS-PSE38, ARE SET AT A NOMINAL VALUE OF 91 PSIG WITH A RANGE OF 86 TO 100 PSIG AT 200^F. REFER TO EDS-AT-002 WHICH WAS TRANSMITTED VIA LETTER NEU-1895. (REFERENCE DCN DM3-00-1029-97)

N/A 9

AC 3-RCS-001-235-4 3-RCS-001-229-2(Z-)

INCORP. DCNS DM3-00-1029-97

& DM3-00-0941-97 MP PAM PAM 10-29

-97 N/A 10 KF INCORP. DCN DM3-00-1905-97 RFL AJS MP MP 1-6

-98 N/A KF 11 INCORP. DCN DM3-00-0682-98 FSAR FIGURE 7-28

-98 RFL RJK RFL SEE NOTE 4 (EM-102F)

TYP 4 PLACES 4.

N/A 12 KF INCORP. DCN DM3-00-0749-98 MP AJS RFL 1-7

-99 N/A KF INCORP. DCN DM3-00-1072-98 13 3-RCS-001-226-1(Z-)

EM-102A N-2 26902 SH 1 8091 V

  • V958(Z-)

3-RCS-001-226-1(Z-)

1" IMB OMB TE 400 2"

  • V894(Z-)

LO CSJ MP AJS 3-10

-99 VALVE IS INSTALLED WITH FLOW OVER THE DISC.

SEE NOTE 4 (EM-102F)

N/A KF INCORP. DCN DM3-00-0961-98 14 RFL AJS AGR 10-13

-99 N/A 15 INCORP. DCN DM3-00-0013-04 EAL DELETED V900 3-RCS-750-249-4 3-RCS-001-248-4

-RV 495 102F DLW DED 2-25

-04 MP CL 602 CL 153 N/A SMC 16 INCORP. DCN DM3-00-0460-05 25212-26902 SH 6 OF 6 16 MP DLW DED 11-7

-05 REV BY DATE SCALE CHKD.

DATE APP.

DATE DWG. NO.

APP.

DATE TITLE STONE & WEBSTER ENGINEERING CORPORATION BOSTON, MASS.

NONE MICROFILM DATE PIPING & INSTRUMENTATION DIAGRAM REVISIONS DURING CONSTRUCTION REV.

DATE DESCRIPTION BY CHK CORR APP S&W DWG. NO.12179-EM-RESP. ENGR:

DESN. ENGR:

12179-EM-A B

C D

E F

G H

I J

K L

M N

4 OPERATIONS CRITICAL P.A. No.

9 1

2 3

5 6

7 8

4 9

1 2

3 5

6 7

8 10 11 NOTE:

MANUAL REVISIONS TO THIS DOCUMENT WHEN AS-BUILT ARE PROHIBITED.

CAD MILLSTONE POWER STATION-UNIT NO. 3 R

Dominion Nuclear Connecticut, Inc.

Millstone Power Station STONE & WEBSTER ENGINEERING CORPORATION BOSTON, MASS.

OPERATIONS CRITICAL STONE & WEBSTER ENGINEERING CORPORATION BOSTON, MASS.

OPERATIONS CRITICAL