ML062220532

From kanterella
Jump to navigation Jump to search
E-Mail from Wayne Walker (Riv) to Kriss Kennedy (Riv) Re Conference Call with CNS on SW Gland Risk
ML062220532
Person / Time
Site: Cooper Entergy icon.png
Issue date: 07/30/2004
From: Webb Patricia Walker
NRC Region 4
To: Kennedy K
NRC Region 4
References
FOIA/PA-2006-0007
Download: ML062220532 (1)


Text

I David Loveless - CONFERENCE CALL WITH CNS ON SW GLANDRJSK Page 11 From:

Wayne C. Walker To:

Kennedy, Kriss Date:

Fri, Jul 30, 2004 1:38 PM

Subject:

CONFERENCE CALL WITH CNS ON SW GLAND RISK

Kriss, Russ and I had a conference call with CNS risk analysts on Friday at 11:30 a.m. we were going through the assumptions for the SDP SERP package on the Cooper service water gland issue. We were about half way through and Russ was called away for an event at CGS. We have rescheduled a conference call with the licensee for 8 a.m. Monday morning, August 2, 2004, with David and you to continue the discussions. The following are some of the questions which were ask by the licensee: They stated that they had sent a SPAR model for David's review-had he been able to review it?, They also stated they had" sent a vendor letter-had David reviewed this?, There were numerous questions regarding the use of NUREG/CR-5496 and difficulties they were having with getting access to the same values David was using for his basic event calculations. They ask several times for us to send them the SPAR model that we were using as a basis for our calculations.

Wayne CC:

Bywater, Russ; Loveless, David; Marschall, Charles; Vonna Ordaz