ML062130089
| ML062130089 | |
| Person / Time | |
|---|---|
| Site: | Pilgrim |
| Issue date: | 07/05/2006 |
| From: | Dan Hoang NRC/NRR/ADRO/DLR |
| To: | Michael Orr Office of Nuclear Regulatory Research |
| References | |
| TAC MC9669 | |
| Download: ML062130089 (4) | |
Text
.James Davis - Re: Draft AMP section of Audit report Page 1 "1 James Davis - Re: Draft AMP section of Audit report Page 11 From:
Dan Hoang To:
Mark Orr Date:
07/05/2006 1:53:08 PM
Subject:
Re: Draft AMP section of Audit report
- Mark, Please make a correction per my attached comments form.
I can be reached at 301-415-3052 if there are any questions.
- Thanks, Dan CC:
James Davis
c:\\temp\\GW)00001.TMP "Page 61 -1=
c:\\temp\\GWIOOOO1.TMP Page 1 Mail Envelope Properties (44ABFC81.F7A:17: 35826)
Subject:
Creation Date From:
Created By:
Re: Draft AIVIP section of Audit report 07/05/2006 1:53:05 PM Dan Hoang DVH@nrc.gov Recipients atlintl.com MPOrr (Mark Off) nrc.gov OWGWPOO3.HQGWDOO1 JAD CC (James Davis)
Post Office Route atlintl.com nrc.gov OWGWPOO3.HQGWDO01 Files MESSAGE comment form.wpd Options Expiration Date:
Priority:
ReplyRequested:
Return Notification:
Concealed
Subject:
Security:
Size 670 21429 Date & Time 07/05/2006 1:53:05 PM 07/05/2006 1:48:39 PM None Standard No None No Standard Junk Mail Handling Evaluation Results Message is not eligible for Junk Mail handling Message is from an internal sender Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled
James Davis-comment form.wpd Page1 Document Review Comment Form Document
Title:
Audit and Review Report for Plant Aging Management Reviews and Programs for Pilgrim Nuclear Power Station Area of Review:
Aging Management Audit Report Section 1. "Introduction and General Information" to Section 3.0.3.3.6.3 "Conclusion."
Reviewer Guidelines:
- 1.
Review for specific area of responsibility and/or expertise.
- 2.
Direct comments to the actions within the scope of the document.
- 3.
Record comment on this form. List page number and line number from document to identify location of proposed change. If comment is extensive or you have marked-up the document, make a notation on this form (e.g., "See comments on markup copy of document.") and return both this form and the marked-up document to the comment coordinator.
- 4.
If information is technically correct, do not change because of personal style preference. You may, however, indicate clearer or more concise wording.
- 5.
If you consider the comment critical and require that you review the revised document before it is approved, put a "Y" in the "Critical Comment" box.
Comment Page Une Comment Critical Comment Resolution No.
No.
No.
Comment?
1 47 31
"...programwill..: Need space in between Y
"...program will.."
2 161 22 "Program procedure. The GALL Report..." New Y
Begin with the new text paragraph (no longer Para.
part of the Enhancement) with:
"The GALL Report...'
3 165 43
'...water-controlstructures..." Need a space in
"...water-control structures...'
between controlstructures
James Davis - comment form.wpd
..Paje 2]
__