ML061870096
| ML061870096 | |
| Person / Time | |
|---|---|
| Site: | Perry |
| Issue date: | 06/30/2006 |
| From: | Shawn Campbell Plant Licensing Branch III-2 |
| To: | |
| S. Campbell X1486 | |
| Shared Package | |
| ML061170066 | List: |
| References | |
| TAC MC7489 | |
| Download: ML061870096 (2) | |
Text
renewal. Such sale and leaseback transactions are subject to the representations and conditions set forth in the above mentioned application of January 23, 1987, as supplemented on March 3, 1987, as well as the letter of the Director of the Office of Nuclear Reactor Regulation dated March 16, 1987, consenting to such transactions. Specifically, a lessor and anyone else who may acquire an interest under these transactions are prohibited from exercising directly or indirectly any control over the licenses of PNPP Unit 1. For purposes of this condition the limitations of 10 CFR 50.81, as now in effect and as may be subsequently.
amended, are fully applicable to the lessor and any successor in interest to that lessor as long as the license for PNPP Unit 1 remains in effect; these financial transactions shall have no effect on the license for the Perry Nuclear facility throughout the term of the license.
(b)
Further, the licensees are also required to notify the NRC in writing prior to any change in: (i) the terms or conditions of any lease agreements executed as part of these transactions; (ii) the PNPP Operating Agreement; (iii) the existing property insurance coverage for PNPP Unit 1; and (iv) any action by a lessor or others that may have an adverse effect on the safe operation of the facility.
C.
This license shall be deemed to contain and is subject the conditions specified in the Commission's regulations set forth in 10 CFR Chapter I and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now and hereafter in effect; and is subject to the additional conditions specified or incorporated below:
(1)
Maximum Power Level FENOC is authorized to operate the facility at reactor core power levels not in excess of 3758 megawatts thermal (100% power) in accordance with the conditions specified herein.
(2)
Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No. 138, are hereby incorporated into the license. FENOC shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
(3)
Antitrust Conditions
- a. FirstEnergy Nuclear Generation Corp. and Ohio Edison Company Amendment No. 138
OPRM Instrumentation 3.3.1.3 SURVEILLANCE REQUIREMENTS NOTE -------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, provided the OPRM maintains trip capability.
SURVEILLANCE FREQUENCY SR 3.3.1.3.1 Perform CHANNEL FUNCTIONAL TEST.
184 days SR 3.3.1.3.2 Calibrate the local power range monitors.
1000 MWD/T average core exposure SR 3.3.1.3.3
NOTE--------------
Neutron detectors are excluded.
Perform CHANNEL CALIBRATION.
24 months SR 3.3.1.3.4 Perform LOGIC SYSTEM FUNCTIONAL TEST.
24 months SR 3.3.1.3.5 Verify OPRM is not bypassed when THERMAL 24 months POWER is ; 23.8% RTP and recirculation drive flow is < the value corresponding to 60% of rated core flow.
NOTE--------------
Neutron detectors are excluded.
Verify the RPS RESPONSE TIME is within 24 months on a limits.
STAGGERED TEST BASIS I