ML061180242

From kanterella
Jump to navigation Jump to search

Ltr to Timothy O Connor - Final Safety Evaluation Report Related to the License Renewal of the Nine Mile Point Nuclear Station, Units 1 and 2
ML061180242
Person / Time
Site: Nine Mile Point  Constellation icon.png
Issue date: 06/01/2006
From: Gillespie F
NRC/NRR/ADRO/DLR
To: O'Connor T
Nine Mile Point
Le, Ngoc, NRR/DLR/RLRA, 415-1458
Shared Package
ML061460333 List:
References
TAC MC3272, TAC MC3273
Download: ML061180242 (5)


Text

June 1, 2006 Mr. Timothy J. OConnor Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093-0063

SUBJECT:

FINAL SAFETY EVALUATION REPORT RELATED TO THE LICENSE RENEWAL OF THE NINE MILE POINT NUCLEAR STATION, UNITS 1 AND 2 (TAC NOS. MC3272 AND MC3273)

Dear Mr. OConnor:

By letter dated May 26, 2004, Constellation Energy Group, LLC (CEG or the applicant) submitted an application to the U.S. Nuclear Regulatory Commission (NRC or the staff) for the renewal of the Nine Mile Point Nuclear Station (NMPNS), Units 1 and 2 operating licenses for up to an additional 20 years. The license renewal application (LRA) was submitted pursuant to Title 10 of the Code of Federal Regulations Part 54, Requirements for Renewal of Operating Licenses for Nuclear Power Plants. The staff determined that the LRA was complete and acceptable for docketing on July 15, 2004. Since that time, the staff has reviewed the original NMPNS LRA and the NMPNS amended LRA (ALRA) dated July 14, 2005, issued requests for additional information (RAIs), reviewed the applicants responses to the staffs RAIs, and developed a safety evaluation report dated March 3, 2006. The NRC staff has previously identified two open items in its review and these have been resolved. On the basis of this review, the staff has developed the enclosed final safety evaluation report to document its findings associated with the safety review of the original LRA and the ALRA and supporting documentation for NMPNS, Units 1 and 2.

If you have any questions regarding this matter, please contact the License Renewal Project Manager, Mr. Ngoc (Tommy) Le at 301-415-1458 or via e-mail at nbl@nrc.gov.

Sincerely,

/RA PTKuo for/

Frank P. Gillespie, Director Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-220 and 50-410

Enclosure:

As stated cc w/encl: See next page

June 1, 2006 Mr. Timothy J. OConnor Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093-0063

SUBJECT:

FINAL SAFETY EVALUATION REPORT RELATED TO THE LICENSE RENEWAL OF THE NINE MILE POINT NUCLEAR STATION, UNITS 1 AND 2 (TAC NOS. MC3272 AND MC3273)

Dear Mr. OConnor:

By letter dated May 26, 2004, Constellation Energy Group, LLC (CEG or the applicant) submitted an application to the U.S. Nuclear Regulatory Commission (NRC or the staff) for the renewal of the Nine Mile Point Nuclear Station (NMPNS), Units 1 and 2 operating licenses for up to an additional 20 years. The license renewal application (LRA) was submitted pursuant to Title 10 of the Code of Federal Regulations Part 54, Requirements for Renewal of Operating Licenses for Nuclear Power Plants. The staff determined that the LRA was complete and acceptable for docketing on July 15, 2004. Since that time, the staff has reviewed the original NMPNS LRA and the NMPNS amended LRA (ALRA) dated July 14, 2005, issued requests for additional information (RAIs), reviewed the applicants responses to the staffs RAIs, and developed a safety evaluation report dated March 3, 2006. The NRC staff has previously identified two open items in its review and these have been resolved. On the basis of this review, the staff has developed the enclosed final safety evaluation report to document its findings associated with the safety review of the original LRA and the ALRA and supporting documentation for NMPNS, Units 1 and 2.

If you have any questions regarding this matter, please contact the License Renewal Project Manager, Mr. Ngoc (Tommy) Le at 301-415-1458 or via e-mail at nbl@nrc.gov.

Sincerely,

/RA PTKuo for/

Frank P. Gillespie, Director Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-220 and 50-410

Enclosure:

As stated cc w/encl: See next page Accession Nos: Pkg - ML061460333; Ltr - ML061180242; SER - ML061460313 OFFICE PM:DLR:RLRB LA:DLR OGC: NLO BC:DLR:RLRC BC:DLR:RLRB BC:DE:EEMB BC:DE:EGCB BC:DE:EEEB NAME NLe YEdmonds (EHylton for)

MZobler KChang (RMathew for)

JZimmerman (SHoffman for)

KManoly (by email)

RKaras (by email)

GWilson (by email)

DATE 05/ 15 /06 05/ 15 /06 05/ 18 /06 05/ 22 /06 05/ 31 /06 05/ 12 /06 05/ 11 /06 05/ 15 /06 OFFICE BC:DE:EQVA BC:DSS:SBPB BC:DSS:SPWB BC:DCI:CFEB BC:DCI:CVIB BC:DCI:CSGB BC:DRA:AFPB BC:DRA:ACVB NAME HHamzehee (by email)

DSolorio (by email)

JNakoski (by email)

KGruss (by email)

(SSheng for)

MMitchell (B. Elliot for - by emai)

AHiser (TBloomer for)

SWeerakkody (by email)

RDenning (by email)

DATE 05/ 17 /06 05/ 17 /06 05/ 16 /06 05/ 17 /06 05/ 16 /06 05/ 17 /06 05/ 16 /06 05/ 10 /06 OFFICE D:DRA D:DE D:DSS D:DCI D:DLR NAME JLyons MMayfield TMartin JGrobe FGillespie (PTKuo for)

DATE 05/ 22 /06 05/ 22 /06 05/ 22 /06 05/ 23 /06 06/ 1 /06 OFFICIAL RECORD COPY

Letter to Timothy J. OConnor from Ngoc Le dated June 1, 2006

SUBJECT:

FINAL SAFETY EVALUATION REPORT RELATED TO THE LICENSE RENEWAL OF THE NINE MILE POINT NUCLEAR STATION, UNITS 1 AND 2 (TAC NOS. MC3272 AND MC3273)

DISTRIBUTION:

JFair RWeisman AMurphy RPettis GGalletti DShum GBagchi SSmith (srs3)

SDuraiswamy YL (Renee) Li RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDe RidsNrrDci RidsNrreEemb RidsNrrDeEeeb RidsNrrDeEqva RidsNrrDss RidsNrrDnrl RidsOgcMailCenter RidsNrrAdes DLR Staff CHolden RLaufer PTam BFuller, RI EKnutson, RI JTrapp, RI TKoshy PYChen HAshar DJeng JBurns MZobler RidsOpaMail

Nine Mile Point Nuclear Station, Units 1 and 2 cc:

Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 126 Lycoming, NY 13093 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Mr. James R. Evans LIPA P.O. Box 129 Lycoming, NY 10393 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Paul D. Eddy Electric Division NYS Department of Public Service Agency Building 3 Empire State Plaza Albany, NY 12223 C. Adrienne Rhodes Chairman and Executive Director State Consumer Protection Board 5 Empire State Plaza, Suite 2101 Albany, NY 12223-1556 Kathryn M. Sutton, Esquire Morgan, Lewis & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street, NW Washington, DC 20005-3502 Mr. Michael J. Wallace President Nine Mile Point Nuclear Station, LLC c/o Constellation Energy Group, Inc.

750 East Pratt Street Baltimore, MD 21202 Carey W. Fleming, Esquire Sr. Counsel - Nuclear Generation Constellation Generation Group, LLC 750 E. Pratt Street, 17th Floor Baltimore, MD 21202 Mr. Peter R. Smith, President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. James Ross Nuclear Energy Institute 1776 I St., NW, Suite 400 Washington, DC 20006-3708 Mr. Mark Flaherty Manager - Fleet Licensing R. E. Ginna Nuclear Power Plant 1503 Lake Road Ontario, NY 14519 Mr. M. Steven Leonard General Supervisor - Nuclear Regulatory Matters Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

Nine Mile Point Nuclear Station, Units 1 and 2 cc:

Mr. Peter Mazzaferro Site Project Manager - License Renewal Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093 Mr. Mike Heffley Senior Vice President and Chief Nuclear Officer Constellation Generation Group 1997 Annapolis Exchange Parkway Suite 500 Annapolis, MD 21401