ML043380317

From kanterella
Jump to navigation Jump to search

TS Pages- Issuance of Amendment Revised Techical Specifications 3.3.1, Reactor Trip System Instrumentation and 3.3.2, Engineered Safety Feature Actuation System Instrumentation
ML043380317
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 12/02/2004
From:
NRC/NRR/DLPM
To:
SHUKLA G , NRR/DLPM/PD4, 415-8420
Shared Package
ML043090247 List:
References
TAC MC0893, TAC MC0894
Download: ML043380317 (2)


Text

RTS Instrumentation 3.3.1 Table 3.3.1-1 (page 3 of 7)

Reactor Trip System Instrumentation APPLICABLE MODES OR NMAL~

8 )

OTHER NOMINA SPECIFIED REQUIRED SURVEILLANCE ALLOWABLE TRIP FUNCTION CONDITIONS CHANNELS CONDITIONS REQUIREMENTS VALUE SETPOINT

10. ReactorCoolant 1(9) 3 per loop M

SR 3.3.1.1 2 89.8% of 90% of Flow-Low SR 3.3.1.7 measured measured SR 3.3.1.10 loop flow loop flow SR 3.3.1.16

11. Reactor Coolant 1(g)

I per RCP M

SR 3.3.1.14 NA NA Pump (RCP)

Breaker Position

12. Undervoltage 1(9) 2 per bus M

SR 3.3.1.9 2 7877 V 8050 V RCPs SR 3.3.1.10 each bus each bus SR 3.3.1.16

13. Underfrequency 1 ()

3 per bus M

SR 3.3.1.9

Ž 53.9 Hz 54.0 Hz RCPs SR 3.3.1.10 each bus each bus SR 3.3.1.16

14. a. Steam 1,2 3perSG E

SR3.3.1.1 214.8%

15.0%

Generator SR 3.3.1.7 (SG) Water SR 3.3.1.10 Level-Low SR 3.3.1.16 Low

b. SG Water 1,2 4

X SR 3.3.1.7 TTD

(Note 3) for Low Trip Time for RCS loop RCS loop AT Delay (TTD)

AT variable variable input input

  • 50.7%

50% RTP RTP TTD=0 and TTD=0 for RCS loop for RCS loop AT variable AT variable input 50%

input > 50.7 RTP

% RTP

15. Not used (continued)

(a) A channel is OPERABLE with an actual Trip Setpoint value outside its calibration tolerance band provided the Trip Setpoint value is conservative with respect to its associated Allowable Value and the channel is re-adjusted to within the established calibration tolerance band of the Nominal Trip Setpoint. A Trip Setpoint may be set more conservative than the Nominal Trip Setpoint as necessary in response to plant conditions.

(g) Above the P-7 (Low Power Reactor Trips Block) interlock.

I DIABLO CANYON - UNITS 1 & 2 3.3-14 Unit 1 -Amendment No. 135, 442, 461-, 178 Unit 2-Amendment No. 435, 442,462,180

ESFAS Instrumentation 3.3.2 Table 3.3.2-1 (page 5 of 7)

Engineered Safety feature Actuation System Instrumentation APPLICABLE MODES OR OTHER NOMINAL (a)

SPECIFIED REQUIRED SURVEILLANCE ALLOWABLE TRIP FUNCTION CONDITIONS CHANNELS CONDITIONS REQUIREMENTS VALUE SETPOINT

5.

Feedwater Isolation (continued)

b. SGWater 1,20) 3 perSG J

SR 3.3.2.1

< 75.2%

75%

Level-High SR 3.3.2.5 High (P-14)

SR 3.3.2.9 SR 3.3.2.10

c. Safety Refer to Function 1 (Safety Injection) for all initiation functions and requirements.

Injection

6. Auxiliary Feedwater
a. Manual 1,2,3 1 sw/pp N

SR 3.3.2.13 NA NA

b. Automatic 1,2,3 2 trains G

SR 3.3.2.2 NA NA Actuation SR 3.3.2.4 Logic and SR 3.3.2.6 Actuation Relays (Solid State Protection System)

c. Not used d.1SG Water 1,2,3 3 perSG D

SR 3.3.2.1 2 14.8%

15.0%

Level-Low Low SR 3.3.2.5 SR 3.3.2.9 SR 3.3.2.10 (continued)

(a) A channel is OPERABLE with an actual Trip Setpoint value outside its calibration tolerance band provided the Trip Setpoint value is conservative with respect to its associated Allowable Value and the channel is re-adjusted to within the established calibration tolerance band of the Nominal Trip Setpoint. A Trip Setpoint may be set more conservative than the Nominal Trip Setpoint as necessary in response to plant conditions.

()

Except when all MFIVs, MFRVs, and associated bypass valves are closed and de-activated or isolated by a closed manual valve.

DIABLO CANYON - UNITS 1 & 2 3.3-31 Unit 1 - Amendment No. 435, -73,178 Unit 2 - Amendment No. 435, 475, 180