ML042810523
| ML042810523 | |
| Person / Time | |
|---|---|
| Site: | Hope Creek |
| Issue date: | 10/05/2004 |
| From: | NRC/NRR/DLPM |
| To: | |
| References | |
| TAC MC1436 | |
| Download: ML042810523 (4) | |
Text
TABLE 3.3.2-1 (Continued)
ISOLATION ACTUATION INSTRUMENTATION TABLE NOTATION TRIP FUNCTION VALVES CLOSED BY SIGNAL
- 7. RHR SYSTEM SHUTDOWN COOLING MODE ISOLATION
- a.
Reactor Vessel Water Level Low, Level 3
- b.
Reactor Vessel (RHR Cut-in Permissive) Pressure - High
- c.
Manual Initiation Low, Level 3 3 (1 BC-HV-F008, 1 BC-HV-F009, I BC-HV-FO1 5A & B) 3 (1 BC-HV-F008, I BC-HV-F009, 1 BC-HV-FO1 5A & B) 3 (1 BC-HV-F008, 1 BC-HV-F009, 1 BC-HV-F01 5A & B)
HOPE CREEK 3/4 3-21 Amendment No. 152
TABLE 3.3.7.4-2 (Continued)
REMOTE SHUTDOWN SYSTEMS CONTROLS RHR SYSTEM - RSP (Cont.)
1 BC-HV-FO07B Control -
1 BC-HV-F048B Control -
1 BC-HV-FO15B Control -
RHR Pump BP202 Minimum Flow Valve to Suppression Pool RHR Loop B Heat Exchanger Bypass Valve RHR Loop B Shutdown Cooling Return Valve 1 BC-HV-F009 Control -
1 BC-HV-F008 Control -
1 BC-HV-F122B Control -
1 BC-HV-4439 Control -
1 BC-HV-F024B Control -
I BC-HV-F047B Control -
1 BC-HV-FO03B Control -
1 BC-HV-F049 Control -
1 BC-HV-F040 Control -
I BC-HV-F06A<3)
Indication-1 BC-HV-F010B13)
Indication -
1 BC-HV-FO16B(3)
Indication -
1 BC-HV-FO27BE3)
Indication -
1 BC-HV-FO17B" 3I Indication -
1 BC-HV-FO04D~2 Indication -
IBC-HV-FO21AI 3" Indication -
1BC-HV-FO21B" 3I Indication -
1BC-BP202 Control -
1BC-HSS-4416B Control -
1BC-DP228' 4' Indication -
RHR Shutdown Cooling Suction From Recirc Line Inboard Isolation Valve RHR Shutdown Cooling Suction From Recirc Line Outboard Isolation Valve RHR Loop B Shutdown Cooling Injection Check Valve Bypass Valve RHR Discharge to Liquid Radwaste Reactor Building Isolation Valve RHR Pump BP202 Test Return Valve to Suppression Pool RHR Loop B Heat Exchanger Shell Side Inlet Valve RHR Loop B Heat Exchanger Shell Side Outlet Valve RHR Discharge to Liquid Radwaste Inboard Isolation Valve RHR Discharge to Liquid Radwaste Outboard Isolation Valve RHR Pump AP202 Suction From Recirc Line Valve RHR Pump DP202 Test Return Valve to Suppression Pool RHR Loop B Containment Spray Outboard Isolation Valve RHR Loop B Suppression Pool Spray Line Isolation Valve RHR Low Pressure Coolant Injection Loop B Injection Valve RHR Pump DP202 Suction From Suppression Pool Valve RHR Loop A Containment Spray Inboard Isolation Valve RHR Loop B Containment Spray Inboard Isolation Valve RHR Pump BP202 Transfer Switch For RHR Pump BP202 ECCS (RHR B) Jockey Pump DP228 HOPE CREEK 3/4 3-78 Amendment No.
152 I.
1ST ISOLATION VALVE(S) NUMBERS(S)
BE-V006 BE-V071 BE-V002 BE-V072 BC-VI 14 BC-V1 19 BC-Vo17 BC-V120 BC-V102 BC-VI21 BC-V005 BC-VI22 TABLE 3.4.3.2-1 REACTOR COOLANT SYSTEM PRESSURE ISOLATION VALVES 2ND ISOLATION VALVE(S) NUMBER(S)
PRESSURE INDICATION SERVICE BE-V007 1-BE-PISH-N654A
'A' Core Spray/
HPCI Injection BE-V003 1-BE-PISH-N654B
'B' Core Spray Injection BC-V1 13 1-BC-PISH-N653A
'A' LPCI Injection BC-V016 1-BC-PISH-N653B
'B' LPCI Injection BC-V101 1-BC-PISH-N653C
'C' LPCI Injection BC-V004 1-BC-PISH-N653D
'D' LPCl Injection BC-V1I1 BC-V1 17 BC-V014 BC-V118 BC-V071 BC-V1 10 BC-VO13 BC-V164 1-BC-PISH-N653A 1-BC-PISH-N653B 1-BC-PISH-N657
'A' Shutdown Cooling Return to 'A' Recirc Loop
'B' Shutdown Cooling Return to 'B' Recirc Loop Shutdown Cooling Supply From 'B' Recirc Loop HOPE CREEK 3/4 4-13 Amendment No. 152 I
TABLE 3.6.3-1 (Continued)
PRIMARY CONTAINMENT ISOLATION VALVES MAXIMUM ISOLATION PENETRATION TIME VALVE FUNCTION AND NUMBER NUMBER (Seconds)
NOTE(S)
P&ID (c) RHR Shutdown Cooling Suction Isolation Valve M-51-1 Outside: HV-F008 (BC-V164)
P3 45 3
(d) RHR Shutdown Cooling Return Isolation Valves M-51-1 Outside:
Loop A: HV-FO1 5A (BC-VI 10)
P4B 45 3
Loop B: HV-FO15B (BC-V013)
P4A 45 3
- 4. Group 4 - Core Spray System Outside:
(a) Core Spray Test to Suppression Pool Isolation Valves M-52-1 Loop A: HV-FO15A (BE-V025)
P217B 80 11 Loop B: HV-FO15B (BE-V026)
P217A 80 11
- 5. Group 5 - High Pressure Coolant Injection (HPCI) System (a) HPCI Turbine Steam Supply Isolation Valves M-55-1 Inside: HV-F002 (FD-VO01)
P7 NA 3
HV-F1OO (FD-VO51)
P7 NA 3
Outside: HV-F003 (FD-V002)
P7 NA 3
(b) HPCI Pump Suction Isolation Valve M-55-1 Outside:
HV-F042 (BJ-V009)
P292 NA 11 HOPE CREEK 3/4 6-21 Amendment No. 152