Letter Sequence Other |
|---|
|
|
MONTHYEARML0333903052003-12-0202 December 2003 Summary of Conference Call Between the NRC and the Southern Nuclear Operating Company Concerning Draft Requests for Additional Information (D-RAIs) on Joseph M. Farley Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: Draft RAI ML0335004422003-12-0505 December 2003 Letter Supporting the Renewal License Application of the Farley Plant Project stage: Other ML0401200572004-01-0909 January 2004 Summary of Telephone Conference Between NRC and Southern Nuclear Operating Co. Concerning Draft Requests for Additional Information on Farley Nuclear Plant, Units 1 and 2, LRA (TAC Nos. MC0774 & MC0775) Project stage: Draft RAI ML0404102932004-02-10010 February 2004 Summary of Telephone Conference Between the NRC & Southern Nuclear Operating Co. Concerning Draft Requests for Additional Information on Joseph M. Farley Nuclear Plant, Units 1 and 2, License Renewal Application (TAC Nos. MC0774 & MC0775) Project stage: Draft RAI ML0404404282004-02-13013 February 2004 Summary of Telephone Conferences Held Between the U.S. NRC and the Southern Nuclear Operating Company Concerning Draft Requests for Additional Information on Joseph M. Farley Nuclear Plant Project stage: Draft RAI ML0406100232004-02-25025 February 2004 & 02/05/2004 Summary of Telephone Conferences Between the U.S. Regulatory Commission and Southern Nuclear Operating Company Concerning Draft Requests for Additional Information on Farley Nuclear Plant, Units 1 and 2 TAC MC0774 & MC0775 Project stage: Draft RAI ML0405806962004-02-26026 February 2004 Summary of Telephone Conferences on Feb. 13, 17 & 18, 2004, Between NRC and Southern Nuclear Operating Company Concerning Draft Requests for Additional Information on Joseph Farley Nuclear Plant, Units 1 and 2, LRA (TAC Nos. MC0774 & MC0775 Project stage: Draft RAI ML0407504192004-03-12012 March 2004 Summary of Telephone Conferences on March 1, 2 and 3, 2004, Between the U.S. Nuclear Regulatory Commission and the Southern Nuclear Operating Company Concerning Draft Requests for Additional Information on Joseph M. Farley Nuclear Plant, Un Project stage: Draft RAI ML0408307482004-03-23023 March 2004 Summary of Meeting and Telephone Conference Between U.S. Nuclear Regulatory Commission and Southern Nuclear Operating Co. Concerning Draft Requests for Additional Information on Joseph M. Farley, Units 1 and 2, License Renewal Application Project stage: Draft RAI ML0409100272004-03-30030 March 2004 Summary of Meeting and Telephone Conference Between the U.S. Nuclear Regulatory Commission and Southern Nuclear Operating Company Concerning Draft Requests for Additional Information on Farley Nuclear Plant, Units 1 & 2, LRA Project stage: Draft RAI ML0409601342004-04-0202 April 2004 03/22, 24 & 25, 2004, Summary of Telephone Conferences Between U.S. Nuclear Regulatory Commission and Southern Nuclear Operating Company Concerning Draft Requests for Additional Information on Joseph M. Farley Nuclear Plant, Units 1 & 2 Project stage: Draft RAI ML0411300972004-04-21021 April 2004 Summary of Telephone Conferences on March 29, 30 and April 2, 2004, Between the U.S. Nuclear Regulatory Commission and the Southern Nuclear Operating Company Concerning Draft Requests for Additional Information on Farley Nuclear Plant, Unit Project stage: Draft RAI ML0411704012004-04-22022 April 2004 Summary of Telephone Conference on 4/7, 4/8 & 4/12, 2004, Between the U. S. NRC and the Southern Nuclear Operating Company Concerning Draft RAIs on Farley Nuclear Plant, Units 1 and 2, LRA Project stage: Draft RAI ML0413803942004-05-17017 May 2004 Summary of Telephone Conferences on April 21, 26 and 30, 2004, Between U.S. Nuclear Regulatory Commission and Southern Nuclear Operating Company Concerning Draft Requests for Additional Information on Farley Nuclear Plant, Units 1 & 2 LRA Project stage: Draft RAI ML0415405282004-06-0202 June 2004 Summary of Telephone Conferences on March 15-18, 2004, Between NRC & SNC Concerning Draft Requests for Additional Information on Joseph M. Farley Nuclear Plant, Units 1 and 2, LRA Project stage: Draft RAI ML0418000882004-06-25025 June 2004 05/17, 20 24, 26 & 06/02, 04 & 07/2004 Summary of Telephone Conferences/Meeting Between NRC & SNC Concerning Requests for Additional Information on Farley, LRA Project stage: RAI ML0418104072004-06-29029 June 2004 Summary of a Meeting Held on June 3, 2004, Between U.S. Nuclear Regulatory Commission and Southern Nuclear Operating Company Concerning Review of Joseph M. Farley Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: Meeting ML0419505092004-07-13013 July 2004 06/21/2004, 06/22/2004, 06/23/2004 & 06/24/2004 Summary of Telephone Conferences with Southern Nuclear Operating Co Regarding the Review for the Farley Nuclear Plant, Units 1 and 2, LRA Project stage: Other ML0420206012004-07-20020 July 2004 And 07/16/2004 Summary of Telephone Conferences Between the U.S. Nuclear Regulatory Commission and the Southern Nuclear Operating Company Concerning the Review for the Joseph M. Farley Nuclear Plant, Units 1 and 2, LRA Project stage: Other ML0421104962004-07-29029 July 2004 Summary of Telephone Conference with Southern Nuclear Operating Co (SNC) Regarding the Review for the Joseph M. Farley Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: Other ML0423804692004-08-25025 August 2004 Summary of Telephone Conferences Held on August 3, 11, and 13, 2004, Between U.S. Nuclear Regulatory Commission and Southern Nuclear Operating Company Concerning Review for Joseph M. Farley Nuclear Plant, Units 1 and 2, License Renew Project stage: Other NL-04-1594, Application for License Renewal - Supplemental Information2004-08-31031 August 2004 Application for License Renewal - Supplemental Information Project stage: Supplement ML0425201772004-09-0808 September 2004 Audit Trip Report Regarding the Southern Company License Renewal Application for the Farley Nuclear Power Stations, Dated September 12, 2003 Project stage: Other ML0425900262004-09-16016 September 2004 Summary of a Telephone Conference Held on September 14, 2004, Between the U.S. Nuclear Regulatory Commission and the Southern Nuclear Operating Company Concerning the Review for the Joseph M. Farley Nuclear Plant, Units 1 and 2, LRA Project stage: Other ML0505503192005-02-24024 February 2005 Summary of a Telephone Conference Held on February 24, 2005, Between the NRC and SNC Concerning the Review for the Joseph M. Farley Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: Other 2004-04-22
[Table View] |
Text
July 29, 2004 LICENSEE:
Southern Nuclear Operating Company FACILITY:
Joseph M. Farley Nuclear Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF A TELEPHONE CONFERENCE HELD ON JULY 26, 2004, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND THE SOUTHERN NUCLEAR OPERATING COMPANY CONCERNING THE REVIEW FOR THE JOSEPH M. FARLEY NUCLEAR PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. MC0774 AND MC0775)
The U.S. Nuclear Regulatory Commission staff and representatives of Southern Nuclear Operating Company (SNC or the applicant) held a telephone conference on July 26, 2004, to discuss applicants response to a request for additional information (RAI) pertaining to the Joseph M. Farley Nuclear Plant (FNP) license renewal application.
The conference call was useful in clarifying the intent of the staffs question. On the basis of the discussion, the applicant was able to better understand the staff's question. No staff decisions were made during the telephone conference, and the applicant agreed to provide information for clarification. provides a list of the telephone conference participants. Enclosure 2 contains a listing of the question discussed with the applicant, including a brief description on the status of the item. The applicant has had an opportunity comment on this summary.
/RA/
Tilda Y. Liu, Senior Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos.: 50-348 and 50-364
Enclosures:
As stated cc w/enclosures: See next page
ML042110496 Document Name: C:\\ORPCheckout\\FileNET\\ML042110496.wpd OFFICE PM:RLEP COOP:RLEP LA:RLEP SC:RLEP NAME TLiu DChen MJenkins SLee DATE 7/28/04 7/28/04 7/28/04 7/29/04
DISTRIBUTION: Dated: July 29, 2004 Accession No.: ML042110496 HARD COPY RLEP RF T. Liu (PM)
D. Chen J. Strnisha E-MAIL:
RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti C. Li M. Itzkowitz (RidsOgcMailCenter)
R. Weisman M. Mayfield A. Murphy S. Smith (srs3)
S. Duraiswamy Y. L. (Renee) Li RLEP Staff C. Julian (R-II)
C. Patterson (R-II)
R. Fanner (R-II)
S. Peters R. Hoefling (OGC)
OPA B. Jain L. Whitney LIST OF PARTICIPANTS FOR TELEPHONE CONFERENCE July 26, 2004 Participants Affiliation Tilda Liu U.S. Nuclear Regulatory Commission (NRC)
James Strnisha NRC David Chen NRC Jan Fridrichsen Southern Nuclear Operating Company (SNC)
Willie Jennings SNC Mike Macfarlane SNC Louis Bohn SNC REVIEW OF LICENSE RENEWAL APPLICATION (LRA) FOR FARLEY UNITS 1 AND 2 July 26, 2004 On July 21, 2004, the staff sent the following question, via e-mail, to the applicant to follow-up on the response to RAI B.5.9-1, Part c, submitted by letter dated July 16, 2004. This question pertains to LRA Section B.5.9 Periodic Surveillance and Preventive Maintenance Activities, which was supplemented by the applicant via letter dated June 18, 2004. Section B.5.9 is a new aging management program that was not in the original LRA. The staffs question and the associated discussion are presented below:
Follow-up to RAI B.5.9-1, Part c The staff requests the applicant to include a specific frequency for the periodic inspections.
RAI B.5.9-1c states that a frequency will be determined when the program is developed.
Discussion: The applicant indicated that it understood the question, and agreed to provide a supplemental response to this question.
Joseph M. Farley Nuclear Plant cc:
Mr. Don E. Grissette General Manager - Plant Farley Southern Nuclear Operating Company Post Office Box 470 Ashford, AL 36312 Mr. B. D. McKinney Licensing Manager Southern Nuclear Operating Company 40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35201-1295 Mr. Stanford M. Blanton, Esq.
Balch and Bingham Law Firm Post Office Box 306 1710 Sixth Avenue North Birmingham, AL 35201 Mr. J. B. Beasley, Jr.
Executive Vice President Southern Nuclear Operating Company 40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35201 Dr. D. E. Williamson State Health Officer Alabama Department of Public Health The RSA Tower 201 Monroe Street, Suite 1500 Montgomery, AL 36130-1701 Chairman Houston County Commission Post Office Box 6406 Dothan, AL 36302 Mr. William D. Oldfield SAER Supervisor Southern Nuclear Operating Company Post Office Box 470 Ashford, AL 36312 Mr. Charles R. Pierce Manager - License Renewal Southern Nuclear Operating Company 40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35201 Mr. Fred Emerson Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Resident Inspector U.S. Nuclear Regulatory Commission 7388 N. State Highway 95 Columbia, AL 36319 Mr. L. M. Stinson Vice President - Farley Project Southern Nuclear Operating Company 40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35201