AmerGen.
An Exelon/British Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 I
Title oyster Creek Emer Program T
. T_
TTonn T.aorn I 3
Revision No.
14 Prior Revision 13 incorporated the following Temporary Changes:
N/A This Revision 14 incorporates the following Temporary Changes:
N/A List of Paces 1.0 to 20.0 El-l to E1-4 E2-1 to E2-2 E3-1 E4-1 to E4-2 E5-1 E6-1 E7-1 E8-1 E9-1 E10-1 NON-CONTROLLED This Document Will Not Be Kept Up To Date DCC Oyster Creek (131901)
- 1. 0
I AmerGen An Exelon/Britsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 DOCUMENT HISTORY REV DATE ORIGINATOR
SUMMARY
OF CHANGE 13 05/92 R. Sullivan Revise section 5.6.3.1 to allow short term change of duty without written notification to security.
14 07/92 Telephone number changes.
15 03/93 Make Exhibits 8 & 9 agree with Emergency Planning update staffing responsibilities.
16 06/94 A. Smith Update NRC telephone number, also Duty Roster.
17 10/94 A. Smith Delete Parsippany Field Monitoring teams.
18 01/95 A. Smith Clarify on shift minimum staffing requirements.
Supplemental positions added to duty roster at Mgt.
discretion.
19 03/95 A. Smith Delete team & position number from teleclerk announcement & replace with nine digit SS #.
0 01/96 A. Smith Correct titles, clarify shift security supervisor in ref. to weekly comm. test.
Revises procedure number to OEP series.
Also clarify drill admin. and include action item training system.
Rev. bars not applicable.
Major rewrite.
I 07/96 T. Blount Update phone numbers for Plant Ops Manager and INPO.
2 10/96 T. Blount Clarify what a Supplemental position holder can do regarding filling an Essential position.
Removed some Supplemental positions.
Changed Duty Roster issuance frequency to as determined by EP Mgr. or Annually whichever is sooner.
3 12/97 P. Hays Incorporate steps for computer configuration controls.
4 05/98 P. Hays Updates Exhibits 2 & 8 to reflect recent changes in two duty roster staffing. Adds note for respirator glasses requirement. Changes Exhibit 9A to reflect recent changes in computer controls.
5 10/98 A. Smith Change reference to action items and use "CAP's" as tracking system.
Add information technologies to the notifications on the Drill Admin. form.
6 04/99 A. Smith Indicate Safety Review required on cover page, reference new E-Plan #,
ERO Test notification to weekly from every Thursday.
7 DOS A. Smith Change reference from GPU to OCNGS, reflect Monday for roster change of duty, add Lotus Notes for D.R.
change of duty, update ERO to reflect PI Pos.
8 04/01 A. Smith Delete position 355, OSC communicator.
9 06/01 A. Smith Update titles in Exhibit 2 for selection mgrs; add 2 Exhibits 9 & 10 to capture duty roster placement of personnel.
10 12/01 A. Smith Update titles, delete the weekly pager test, clarify duty roster process/responsibilities, update duty poster; discrimination process from hard copy to Lotus Notes.
11 01/02 A. Smith Remove requirements for respirator qualifications for certain ERO positions (131901) 2 -0
AmerGenm An Exelon/British Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number I
OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 12 08/02 J. Bontempo Reword 4.4.3, 4.4.4, 5.6.1.2 Exh. 9, Step 7 to replace Teleclerk with Dialogic Correct Exh. 1 3c Phone number for NRC Ops Ctr.
Corrected Exh reference in Step 3.5.3 changed procedure reference in Step 4.5 to reflect LS-AA-2110 Exh 7 Steps 3 e,f,g,h added EP Coordinator Correct Exh 1, 3j phone number for Ocean County Sheriff Correct Exh 1, 4 IT Help Desk Correct Exh. 2, Station Support Director Plant Manager 13 02/02 P. Thompson 5.6.3 -
Clarify use of Lotus Notes Duty Exchange process.
Ex 1 -
Updated drill admin guide for improved drill preparation activities 14 03/18 M. Chanda 3.5.1.1 -
Revised reference to 2612-PGD-2685 4.5 -
Revised reference to EP-MA-125-1003 5.3.8 -
Corrected reference from Exh. 6 to Exh. 5 6.4 -
Revised reference to 1000-ADM-2002.04 6.9 -
Revised reference to IT-AA-101 (131901)
- 3. 0
AmerGen OYSTER CREEK Number AnE___________opn EMERGENCY PREPAREDNESS OEP-ADM-1319.01 An Exelon/Brtish Enerympany IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 1.0 PURPOSE This procedure defines the Oyster Creek Emergency Preparedness Program requirements and maintenance.
2.0 APPLICABILITY/SCOPE 2.1 This procedure applies to Oyster Creek personnel in their activities at Oyster Creek relating to emergency preparedness.
2.2 This procedure delineates Oyster Creek responsibilities as assigned in 2000-PLN-1300.01, OCNGS Emergency Plan.
3.0 DEFINITIONS 3.1 Emergency Duty Roster -
Consists of all Initial Response Emergency Organization (IREO) and Emergency Support Organization (ESO) personnel.
3.2 Oyster Creek Emergency Plan Implementing Document -
This document shall include Emergency Plan Implementing Procedures and should include Emergency Preparedness Administrative Procedures.
3.3 Oyster Creek EmerQency Preparedness ProQram -
The program implemented by Oyster Creek Division, Support Divisions, and the Oyster Creek Emergency Preparedness Section to maintain a high level of emergency preparedness.
3.4 Essential Positions -
Consist of those duty roster positions (personnel) described in the Emergency Plan.
These positions are presented in Exhibit 6.
3.4.1 Essential positions also include the On-Shift Personnel required to meet the minimum staffing requirements of Table 5 of 2000-PLN-1300.01, OCGS Emergency Plan.
(131901)
- 4. 0
OYSTER CREEK Number Amer__
EMERGENCY PREPAREDNESS OEP-ADM-1319.01 An Exelon/British Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 3.5 Supplemental Positions -
Consist of those duty roster positions (personnel) not required by the Emergency Plan.
3.5.1 Supplemental positions shall be trained as a minimum in accordance with Oyster Creek Emergency Plan Section 8.2.1, Step 1.
3.5.1.1 Supplemental positions should receive training in accordance with the Emergency Preparedness Training Program description 2612-PGD-2685, as a good practice, but it is not required.
3.5.2 Supplemental positions may fulfill the duties and responsibilities of an essential position if their training and qualification meet the minimum requirements as applicable for that position in Exhibit 4.
3.5.3 The supplemental positions are identified on the duty roster by the mid position number of 5 or higher in the three digit "position" identifier (e.g.; X5X, X6X, X7X, etc.).
These positions are listed in Exhibit 7.
4.0 RESPONSIBILITIES 4.1 Directors. Managers and Supervisors shall:
4.1.1 Provide assistance in scenario preparation by developing supporting data and/or ensuring technical accuracy and credibility as requested.
4.1.2 Provide drill observers and controllers to assist in the conduct and evaluation of emergency drills and exercises as needed.
4.1.3 Nominate individuals from their organization for Initial Response Emergency Organization and Emergency Support Organization positions, as specified in Exhibit 2, Emergency Duty Roster Staffing Responsibilities, to fill current or projected vacancies on the Emergency Duty Roster.
(131901)
- 5. 0
OYSTER CREEK Number EMERGENCY PREPAREDNESS OEP-ADM-1319 01 An Exelon/Bntish Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 4.1.3.1 Individuals currently holding a position on the Emergency Duty Roster may be trained for other Roster positions but should not be assigned more than one position on the duty roster.
4.1.3.2 Individuals must complete initial training/retraining for the Roster position to which they are nominated prior to being assigned to the Roster unless a valid exception is documented in accordance with the Training Program.
4.1.4 Monitor their personnel's progress in achieving and maintaining proficiency on Emergency Preparedness assignments.
This should be recognized in Employee Performance reviews.
4.1.5 Ensure that they and their personnel attend scheduled Emergency Preparedness training.
4.1.6 When necessary submit "Drill Exemption List" Exhibit 6, to the Plant Manager (or designee) for approval at least twenty four (24) hours prior to the Drill date.
4.2 The Emergency Preparedness Section -
OC shall:
4.2.1 Schedule the training and retraining of Emergency Duty Roster personnel to maintain personnel training requirements current and provide timely notification of necessary training to appropriate personnel.
4.2.2 Develop, implement and maintain the Oyster Creek Emergency Preparedness Training Program within the guidance set forth in Reference 6.1 and 6.5.
(131901)
- 6. 0
AmerGenl An ExelonfBritish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
14 Oyster Creek Emergency Preparedness Program
.1.
4.3 The Emergency Preparedness Manager/Site Coordinator -
OC is responsible for the overall development, implementation and maintenance of the Oyster Creek Emergency Preparedness Program.
The Emergency Preparedness Manager - OC shall:
4.3.1 Plan, coordinate, implement and evaluate drills and exercises.
4.3.2 Maintain Emergency Duty Roster and issue Confidential Telephone Information listing when the Mgr. determines sufficient Org./Personnel changes warrant revision or at least annually whichever is more frequent. The Roster should be reviewed by the Emergency Prep Manager, approved by the Duty Roster Coordinator & Senior Site Management.
4.3.3 Direct the issuance of a Initial Response Emergency Organization Duty Schedule for Drills/Exercises annually.
4.3.4 Review/concur on the Emergency Preparedness Training Program Description and related lesson plans and exams for technical accuracy and conformance with the Emergency Plan.
4.3.5 Maintain the Emergency Preparedness Surveillance Program and accompanying documentation.
The Program includes, but is not necessarily limited to:
4.3.5.1 Installed equipment operability and performance testing.
4.3.5.2 Reviews and audits of Emergency Response Facilities and equipment readiness.
4.3.5.3 Periodic updating of Letters of Agreement and emergency phone numbers.
4.3.5.4 Ensuring the technical adequacy of Emergency Preparedness Section staff personnel.
(131901) 7.0
-AmerGen-OYSTER CREEK Number EMERGENCY PREPA-REDNESS OEP-ADM-1319.01 1-I
________________________VL1r"V-Title Revision No.
Oyster Creek Emergency Preparedness Program 14 4.3.6 Review the Oyster Creek Emergency Preparedness Program to ensure satisfactory overall performance.
4.3.7 Track to completion "CAP" items related to emergency preparedness.
4.3.8 Control and revise Emergency Plan implementing procedures to reflect current information consistent with the latest revisions to the Emergency Plan and changes to EP facilities, equipment and documents.
4.3.9 Maintain and program as necessary the Emergency Response Organization Notification system.
Review data derived from notification system tests and take corrective action for unsatisfactory results.
4.3.10 Perform critiques of actual implementations of the Emergency Plan (eg., any declared emergency).
4.4 Personnel assigned to the Initial Response and Emergency Support Organization Duty Roster are responsible to:
4.4.1 Ensure that their assigned radio pager is operable and turned on when on duty and take positive action to replace their pager if it fails.
4.4.2 Ensure that they are available to report for duty in accordance with the Fitness For Duty Policy within the required time during the period when they are on duty.
Obtain a qualified replacement in accordance with Section 5.6.3 to carry out the assigned duties and responsibilities when any situation prevents him/her from performing his/her duty assignment on a short-term basis.
(131901)
- 8. 0
AmerGenm An Exelon/Bribtsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 4.4.3 Call Dialogic at the 800 number that appears on the pager any time the pager activates by a group code and follow the instructions provided by Dialogic System.
NOTE If the Dialogic cannot be reached, or there is a discrepancy between pager message code and Dialogic message, report to your assigned ERF.
4.4.4 Acknowledge the phone message provided by the Dialogic System, if contacted at home, and follow the instructions provided by the Dialogic System.
4.4.5 Ensure that the Emergency Preparedness Section has their current telephone numbers (office and home).
4.4.6 Maintain respirator and training qualifications.
NOTE Personnel in positions that require the use of respirators an require eye glasses must have the appropriate respirator eye glasses available at all times when on duty.
4.5 Key members of the IREO and ESO should perform in, or observe a drill/exercise every 18 months (+ 25%).
These members are identified in EP-MA-125-1003. At the discretion of EP Management key personnel who do not meet this criteria may be removed from the duty roster until the criteria is met.
ad (131901)
- 9. 0
A eG OYSTER CREEK Number meren_
EMERGENCY PREPAREDNESS OEP-Am-1319. 01 An Exelon/Britsh Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.0 PROCEDURE The Oyster Creek Emergency Preparedness Program consists of the following elements:
5.1 Development, implementation and maintenance of the Emeraency Plan Implementing Document - This document, as defined in Section 3, implements the Oyster Creek Emergency Preparedness Program.
5.2 Emergency Preparedness Training Program -
This program is governed by Reference 6.1 and conducted in accordance with the Oyster Creek Training Department Procedures.
5.3 Emergency Drills and Exercises 5.3.1 An exercise is an evaluated demonstration of major portions of emergency response capabilities.
An exercise tests the integrated capability of the emergency response organization to identify weaknesses that could affect the response to an actual emergency.
Exercises usually involve a large radiological release affecting the off-site populace and usually involve the full or partial participation of federal, state, and local agencies.
(ref: INPO 88-019) 5.3.2 A drill is an evolution conducted to develop and maintain key emergency response skills.
Drills are usually narrower in scope than exercises and can be used to train a specific area of response such as fire response, medical response, or interagency communications. Drills can also be used to train for integrated response of the emergency organization.
Drills should be used to practice and promote a high state of readiness and teamwork within and between on-site facilities and disciplines.
Drills can be used to correct deficiencies identified in exercises.
(ref: INPO 88-019)
(131901)
- 10. 0
AmerGenOYSTER CREEK Number
__Er Any EMERGENCY PREPAREDNESS OEP-ADM-1319.01 Anl Exelonl~disb Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.3.3 Periodic drills and exercises will be conducted in order to assess the state of emergency preparedness.
The prime objective of this form of training is to verify the emergency preparedness of all participating personnel, organizations, and agencies.
Each drill or exercise will be conducted to:
(1) ensure that the participants are familiar with their respective duties and responsibilities, (2) verify the adequacy of the Emergency Plan and the methods used in the Emergency Plan Implementing Documents, (3) test communications networks and systems, (4) check the availability of emergency supplies and equipment, and (5) verify the operability of emergency equipment.
In addition, repair and damage control shall be included in one major drill/exercise on an annual basis. (ref:
OCNGS E-Plan) 5.3.3.1 Medical Emergency Drill Medical Drill shall be conducted annually.
The drill will involve the participation of local medical support personnel and organizations (e. g.,
physician, ambulance service, hospital), and will involve simulated (injured) contaminated personnel.
5.3.3.2 Fire Emergency Drill Fire drills shall be conducted in accordance with the site Fire Protection Plan.
5.3.3.3 Radiological Monitoring Drill Radiological Drill shall be conducted annually.
The drill shall include collection and analysis of all appropriate sample media for both onsite and offsite locations.
(131901) 11.0
Am r
e
-OYSTER CREEK Number Anel s
comanyEMERGENCY PREPAREDNESS OEP-ADM-1319. 01 An Exelon/BrSEneCompany IMPLEMENTING DOCUMENTr Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.3.3.4 Radiological Controls Drill At least one drill shall be conducted semi-annually.
The drill will involve response to, and analysis of, simulated elevated airborne and liquid samples and direct radiation measurements.
The drill shall include analysis of inplant liquid samples with simulated elevated activity levels.
5.3.3.5 Hazardous Material Spill Drill Hazardous Material Spill Drills shall be conducted as required by the OCNGS Environmental Control Plan.
5.3.3.6 Biennial Exercises
- a. The OCGS Emergency Plan shall be tested biennially to include a scenario with a Site Area or General Emergency.
State and local government emergency plans will be included with full or partial participation by state and local governments within the Plume Exposure Pathway EPZ as required by federal regulations.
- b. Conduct of the exercise shall include mobilization of onsite and offsite emergency response personnel and resources in order to verify their capability to respond to an emergency.
Communications with State and County agencies will be included.
The scenario will be varied from year to year such that all major elements of these plans and preparedness organizations are tested within a six year period.
Once within each six year period an exercise will be started in accordance with NRC and FEMA objectives for off-normal hours.
(131901) 12.0
AmerGen OYSTER CREEK Number An___elo___r___
EMERGENCY PREPAREDNESS OEP-ADM-1319.01 An Exelon/BtSh Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.3.4 "Hands-On/OJT" Drills will be conducted when it is determined additional training or experience will enhance an individual, selected group, facility staff or the ERO's ability to respond to emergency conditions.
This session may take the form of a walk-through or a table-top discussion of an evolution/operation.
This type of drill is distinct from those described in Section 5.3.3 in that the focus is limited and will generally not include an integrated response.
5.3.5 Actual Emergency Plan Activations may be credited in place of selected drills if the Emergency Preparedness Manager deems it appropriate.
Generally an Alert or higher level emergency may be substituted for a Drill.
Such events may also replace an Exercise with NRC approval.
5.3.6 Drill Controllers and Evaluators will be selected from the Plant and supporting divisions based on their specialized expertise.
Selection will be based on Company Organizational Position and/or Emergency Response Organization qualifications.
5.3.7 Drill attendance may be conducted by the facility drill controller/evaluators. Attendance sheets should be signed by the participants for drill credit.
Attendance sheets should be returned to the Emergency Preparedness Section for documentation.
5.3.8 Personnel may be exempted from drill participation by submitting a copy of a completed Exhibit 5. This should be submitted at least twenty-four (24) hours prior to the scheduled drill date.
Should a member of the Team/Priority participating in the Drill require exemption, the Director, Manager, or Supervisor requesting the exemption shall make all necessary arrangements for coverage of that position during the drill.
The Drill Exemption List must be approved by the Plant Manager or his designee.
Completed copies shall be sent to Shift Security Supervisor's Office -
Main Gate and Emergency Preparedness Office.
13.0 (131901)
OYSTER CREEK Number AmerGen_
EMERGENCY PREPAREDNESS OEP-ADM-1319 01 An Exelon/British Energy Company IMPLEMENTING DOCUMENT
_M_
Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.3.9 NRC Administrative Letter 94-16 (dated November 30, 1994) provides revised guidance concerning NRC Core Inspection Program for Annual E.P. exercises.
5.3.9.1 The letter revised the inspection frequency for performing specific inspection modules (Evaluation of Exercises for Power Reactors and Review of Exercise Objectives and Scenarios for Power Reactors) from annual to biennial.
5.3.9.2 An Annual exercise will be conducted in accordance with 10CFR50 App. E and submittal of exercise scenarios and objectives will be done biennially, in accordance with IN-94-16.
5.3.10 All drills and exercises will be documented using Exhibit 1.
Any items which do not pertain to a particular exercise or drill should be noted "N/A'.
5.4 Emergency Preparedness Surveillance Program -
Included in the Oyster Creek Emergency Preparedness Procedure Manual as OEP-SUR-1310 series.
5.5 Emergency Response Facilities and Equipment Readiness -
These facilities and associated equipment will be maintained in accordance with OEP-ADM-1319.02, Emergency Response Facilities and Equipment Maintenance.
(131901) 14.0
AmerGenl An Exelon/Uritish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01
\\__/.Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.6 Emergency Response Organization - The maintenance of the Emergency Response Organization will be as follows:
5.6.1 Nomination and approval process.
5.6.1.1 Responsible Directors, Managers and Supervisors as listed in Exhibit 2, Emergency Duty Roster Staffing Responsibilities, should nominate individuals from the OCGS organization to fill current or projected vacancies in the Emergency Duty Roster.
- 1. The nominating Director, Manager or Supervisor shall ensure that nominated individuals meet the criteria outlined in Exhibit 4, Qualification Requirements for Essential Personnel.
5.6.1.2 Site Emergency Preparedness shall review the nominated individual's Emergency Preparedness training to ensure proper completion.
- 1. If the nominee has not completed Emergency Preparedness training, the appropriate training should be scheduled in a timely manner.
- 2. Once training has been completed the Emergency Duty Roster and Dialogic System shall be updated in accordance with Exhibit 10.
5.6.1.3 Personnel with lapsed qualifications which are not renewed shall be removed from the Duty Roster.
Reinstatement shall be in accordance with 5.6.1.
nfI 15.0 I I 1 k L1:7W
-L'V
_ AmerGen An Exelon/Bntish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
14 Oyster Creek Emergency Preparedness Program 5.6.2 Emergency Duty Rosters and Schedules 5.6.2.1 The Emergency Duty Roster shall be revised, in the Duty Roster Database as changes occur.
The Dialogic System will be updated as changes occur, in a timely fashion.
5.6.2.2 Periodically a Confidential Telephone Information listing will be published and distributed.
This phone listing will be distributed to the following:
- Shift Security Supervisor's Office
- Emergency Control Center
- Technical Support Center 5.6.2.3 The Drills/Exercise Schedule will be published and distributed each calendar year.
5.6.3 Duty Roster/Schedule Changes 5.6.3.1 An exchange of duty to the IREO or ESO Duty Schedule will be accomplished by the duty assignee submitting a notice via Lotus Notes EP Duty Roster Exchange to the Emergency Preparedness Manager or designee with a copy to the Site Security Manager in advance of the change.
The notice will be retained until the change is no longer effective.
NOTE A Lotus Notes Application is available to electronically submit a "Notice of Temporary Change of Duty". This is the preferred method of exchanging duty.
(131901)
- 16. 0
A nerGen.
OYSTER CREEK Number An_____
_EerGy Ca EMtERGENCY PREPAREDNESS OEP-ADM-1319.01 An Exelon/Bntsh Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.6.3.3 Personnel changes to the Emergency Duty Roster will be made by submitting a notice similar to the Emergency Duty Roster Change form and processed according to Section 5.6.1.
Appropriate measures should be taken by the responsible managers to ensure all positions remain fully staffed.
5.6.4 Initial Response Emergency Organization (IREO) Team Duty Period 5.6.4.1 The normal period of on-call duty for the Initial Response Emergency Duty Roster Teams is 1600 hours0.0185 days <br />0.444 hours <br />0.00265 weeks <br />6.088e-4 months <br /> Friday to 1600 hours0.0185 days <br />0.444 hours <br />0.00265 weeks <br />6.088e-4 months <br /> Friday of the following week.
Exceptions to this period are noted on the annual published duty schedule.
During this period IREO members on duty shall be fit for duty in accordance with the employee Fitness for Duty Program (Reference 6.4).
The OCGS Duty Roster Schedule identifies duty periods for all teams.
5.6.5 Emergency Support Organization Team Duty Period 5.6.5.1 The ESO will follow duty rotation in accordance with Section 5.6.4.1.
During the duty period these teams shall comply with the Employee Fitness for Duty program (Reference 6.4).
The OCGS Duty Roster Schedule identifies duty periods for all teams.
5.7 Corrective Action Process (CAP) -
Issues related to the conduct of the Emergency Preparedness Program should be entered into the CAP System.
A self assessment of EP CAP items should be conducted each year not to exceed 15 months.
The assessment should look for trends as described in 2000-ADM-7216.01.
t 1
qn1117.0
%1
-L.-
- FU I
A eG OYSTER CREEK Number EMERGENCY PREPAREDNESS OEP-ADM-1319.01 An Exelon/BEntish Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.8 Control of Software 5.8.1 Software developed or maintained by Emergency Preparedness shall be protected from unauthorized modification by:
5.8.1.1 Limiting distribution of uncompiled source code to those specifically authorized to modify the code.
5.8.1.2 Maintaining backup copies of source code 5.8.1.3 Maintaining backup copies of unprotectable external data.
5.8.1.4 Periodically creating backup copies of accumulated results data.
5.8.1.5 Software control is in accordance with IT-AA-101,, DTS Applicability Matrix.
5.8.2 Software shall have a specified responsible individual, who will:
5.8.2.1 Be a point of contact for user comments.
5.8.2.2 Notify users of errors or omissions.
5.8.2.3 Coordinate modification.
5.8.2.4 Ensure distribution of revisions to authorized users.
5.8.3 In house software shall be tested:
5.8.3.1 Before initial distribution.
5.8.3.2 After revision.
5.8.3.3 Such test result documentation may be flexible based on the nature of the software or degree of revision.
(131901)
- 18. 0
AmerGen OYSTER CREEK Number AnE_______
_Cmpany EMERGENCY PREPAREDNESS OEP-ADM-1319 01 An Exelon/Brtsh EnergyCompany IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 5.8.3.4 Documentation for other than 'non-substantive changes' shall be permanent (memo, formal calculation when applicable, etc.).
Use Exhibit 9 Software Configuration Control Change Request.
Additional supporting documentation should be attached.
NOTE Changes which could reasonably be expected to affect record retention or numerical accuracy shall be considered substantive.
EXAMPLE:
a change which adds the date to a printout may be non-substantive, a change which alters global results data file structures may be substantive even though no actual calculations are modified.
5.8.4 Vendor Supplied Software shall be tested:
5.8.4.1 For operability on available equipment.
5.8.4.2 For accuracy of results.
6.0 REFERENCES
6.1 OCGS Emergency Plan, 2000-PLN-1300.01 6.2 Emergency Preparedness Procedure, OEP-ADM-1319.02, Emergency Response Facilities and Equipment Maintenance 6.3 Oyster Creek Emergency Plan Implementing Document 6.4 Employee Fitness for Duty Procedure/Drug and Alcohol 1000-ADM-2002.04.
6.5 2612-PGD-2685 Emergency Preparedness Training Program.
6.6 INPO Document -
88-019 -
Emergency Preparedness Drill and Exercise Manual.
6.7 Corrective Action Process 2000-ADM-7216.01.
6.8 10CFR50 6.9 IT-AA-101 Digital Technology Systems (DTS) Quality Assurance 6.10 LS-AA-2110, Monthly Performance Indicator (PI) Data Elements for Emergency Response Organization (ERO) Drill Preparation.
(131901)
- 19. 0
AmerGenm An Exelon/British EneTgy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 7.0 EXHIBITS 7.1 Exhibit 7.2 Exhibit 7.3 Exhibit 7.4 Exhibit 7.5 Exhibit 7.6 Exhibit 7.7 Exhibit 7.8 Exhibit 7.9 Exhibit 1,1 2,
3,
4, 5,1 6,
7, 8,
9,1 Example Drill Administrative Guide Form Emergency Duty Roster Staffing Responsibilities Example Notice of Temporary Exchange of Duty Qualification for Essential Personnel Drill Exemption List Emergency Response Organization Essential Positions Emergency Response Organization Supplemental Positions Software Configuration Control Change Request Duty Roster Placement of Personnel 7.10 Exhibit 10, Lotus Notes Duty Roster Database Information I
(131901)
- 20. 0
OYSTER CREEK Number Ameren_
EMERGENCY PREPAREDNESS OEP-AfM-1319.01 An Exelonf8rtsh Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 1 DRILL ADMINISTRATIVE GUIDE FORM
- 1. Classification and Scheduling The Emergency Preparedness Manager or his designee shall circle the appropriate title below and note the date and time the drill is to be held.
TIME
/
DATE DATE
/ INITIALS
- Drill
/
- Dress Rehearsal
/_
- Annual Exercise
/
- 2. Scenario Development The Emergency Preparedness Manager or his designee shall be responsible for the drill scenario preparation as well as obtaining scenario review from personnel listed below.
Scenario #
Revision
/
SRO (Name)
RAD PRO OR RAD ENGINEERING SUPERVISOR (Name)
OTHER REVIEW (131901/S3)
El-1
AmerGen.
OYSTER CREEK EMERGENCY PREPAREDNESS Number OEP-ADM-1319.01 An
... m/
Io --- ~gy I
u 1WPWQ N~.MLEMN TIN VUUULM6N-;L'.
Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 1 (Continued)
DRILL ADMINISTRATIVE GUIDE FORM
- 3. Outside Agencv Notification The Emergency Preparedness Manager or his designee is responsible for coordinating efforts with outside participating emergency personnel and organizations and notify the agencies indicated below;
- a. New Jersey State Police Emergency Operations Center (609) 882-4201
- b. Ocean County Department of Emergency Services (732) 341-3451
- c. NRC Operations Center, Rockville, Md.
(800) 449-3694 If no answer call (301) 951-0550)
DATE
/ INITIALS
_____________________________/_________________
/_________________
___________________________/_______________
(Specify Name)
- d. Resident NRC Inspector (609) 971-4978
- f. Community Medical Center [Nursing Services Supv.
(732) 240-8000 (at discretion of EP Manager or EP Coordinator.
- g. Southern Ocean County Hospital [Nursing Service Supervisor (609) 597-6011] (at discretion of EP Manager or EP Coordinator)
_____________________________/_________________
_____________________________/_________________
/______________
___________________________I_______________
___________________________I_______________
Specify Which)
- i. INPO Emergency Ops Center (800) 321-0614
- j.
Ocean County Sheriff's Comm. Center (732) 349-2010 or (732) 349-2094
- k. Lacey Township Police Dept. (609) 693-6636
- 1. Ocean Township Police Dept. (609) 693-4007
_____________________________/_________________
___________________________/________________
___________________________/________________
_____________________________/_________________
(131901/S3)
El-2
AmerGen An Exelon/British EneTgy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 I
Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 1 (Continued)
DRILL ADMINISTRATIVE GUIDE FORM DATE
/ INITIALS
_____________________________/________________
- m.
Other (Specify)
- 4. Information Technologies Help Desk
___________________________/_______________
- 5. Plant Notification
- a. Vice President, Oyster Creek
_______________________________ / __________________
___________________________/_______________
- b. Plant Manager
- c.
Site Security Manager
_____________________________/_________________
- d. Communications
_____________________________/_________________
I_______________
- e. Work Management Note Work management will be notified of scheduled drills and exercises with sufficient notice to ensure site resources are properly scheduled and reserved.
Such resources include Maintenance, RP, and Chemistry personnel to support in-field activities, and vehicles as necessary, to minimize impact on scheduled work.
Note:
- 6. Observers The Emergency Preparedness Manager is responsible for assigning observers to monitor personnel and areas involved in the drill.
All plant and supporting departments are responsible for providing technically qualified observers to assist in drill observation and evaluation.
- a.
Assign all observers.
- b. Publish memo providing date, times & locations to all observers.
- c. Verify operability of observer/contractor phone circuits.
- 7. Pre-Drill Meeting Meet with all observers and other non-player personnel involved with the drill to brief them on scope, sequence of events and responsibilities.
_____________________________/_________________
___________________________/________________
_____________________________/_________________
_____________________________/_________________
(131901/S3)
El-3
AmerGen.
An Exelon/Brttish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCY~dENT Number OEP-ADM-1319.01 I
I Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 1 (Continued)
DRILL ADMINISTRATIVE GUIDE FORM
- 8. Shift Participation The operating shift(s) actually tested in the drill/exercise should be listed.
DATE
/ INITIALS
_____________________/________
- 9. Post Drill Reauirements Upon completion of the drill, the Emergency Preparedness Manager is responsible for meeting with all observers and holding a critique to review and discuss deficiencies and corrective actions.
- a. Meet with all observers to review their significant comments, if possible.
- b. Hold drill critique to review drill with involved personnel.
- c. Collect signed Observer comments as available.
- d. Collect Drill Attendance Forms, if used.
- e. Empty Lotus Notes database after drill report approval.
_____________________________I_________________
_______________________________/
_____________________________/_________________
_____________________________/_________________
___________________________/_______________
- 10. CAP Process The Emergency Preparedness Manager or his designee is responsible for developing CAP's based upon drill recommendations.
- a. Develop Action Items.
- 11. Documentation and Routing of Drill and Criticzue Results The Emergency Preparedness Manager or his designee is responsible for ensuring that all documents generated as a result of the drill are collected and forwarded to appropriate personnel and/or departments.
- a. Prepare and distribute Drill or Exercise Critique memo.
- b. Forward the completed drill packet to Document Control.
Items included in the Drill Packet are the following:
_____________________________/_________________
_____________________________/_________________
_____________________________/_________________
1.
2.
3.
List of Observers Drill Critique Completed Drill Administrative Guide Form (Exhibit 1)
- c. Forward Drill Attendance Forms to Training Administrative Support
_____________________________/_________________
(131901/S3)
El-4
AmerGen.
OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 An Exelon/Eribtsh Energy Company Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 2 Emergencv Duty Roster Staffing Responsibilities Duty Roster Position Responsibility for Staffing EMERGENCY CONTROL CENTER 101 102 103 104 Operations Coordinator ECC Communications Coordinator ECC Communicator ECC Communicator Plant Manager Plant Manager Engineering Plant Manager TECHNICAL SUPPORT CENTER 201 202 203 204 205 2 06 207 208 210 250 253 658 Emergency Director ED Assistant Rad Assessment Coordinator Rad Engineering Support TSC Coordinator TSC Engineer (Mech)
TSC Engineer (Elec)
TSC Engineer/I & C Core Engineer TSC Communications Coordinator Tech Assistant Computer Eng.
Plant Manager Plant Manager Plant Manager Plant Manager Director Engineering Director Engineering Director Engineering Director Engineering Director Engineering Director Engineering Director Engineering Director Engineering OPERATIONS SUPPORT CENTER 301 302 303 304 306 350 351 353 354 OSC Coordinator Emergency Maintenance Coordinator Rad Control Coordinator Chemistry Coordinator Security Coordinator Maintenance Team Coordinator Emergency Maintenance Electrical OSC Communications Coordinator OSC Communicator (Operations)
Maintenance Director Maintenance Director Plant Manager Plant Manager Plant Manager Maintenance Director Maintenance Director Maintenance Director Maintenance Director (131901/S4)
E2-1
AmerGen.
An Exelon/Britsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 2 Emergency Duty Roster Staffing Responsibilities Duty Roster Position Responsibility for Staffing OFF-SITE RADIOLOGICAL MONITORING TEAMS 450 451 452 453 Rad/Env Survey Team A Leader Rad/Env Survey Team A Assistant Rad/Env Survey Team B Leader Rad/Env Survey Team B Assistant Plant Manager Plant Manager Plant Manager Plant Manager EMERGENCY ASSEMBLY AREA 501 Emergency Assembly Area Coordinator Work Management Director EMERGENCY OPERATIONS FACILITY 601 602 603 605 606 607 608 609 610 612 650 651 652 653 654 Emergency Support Director ESD Assistant Group Leader R&EC EOF Communications Coordinator EOF Communicator EOF Communicator Tech Support Representative Group Leader -
Administrative Support Emergency Preparedness Representative P.I. Tech Rep/Com Tech Support Staff Tech Support Staff Tech Support Staff Administrative Support Staff Material Management Coordinator Vice President Vice President Plant Manager HR Manager HR Manager HR Manager Director Engineering Work Management Director Plant Manager HR Manager Director Engineering Director Engineering Director Engineering Work Management Director Work Management Director ENVIRONMENTAL ASSESSMENT COMMAND CENTER 801 Environmental Assessment Coordinator 802 Met/Dose Assessment Coordinator Plant Manager Plant Manager JIC 910 911 912 913 952 Media Center Lead -
Com Media Ct. Advisor/Communicator PI Tech Rep -
Com PI Rep -
Com JIC Admin./Communicator HR HR HR HR HR Manager Manager Manager Manager Manager (131901/S4)
E2 -2
AmerGen.
An Exelon/Britsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 II Title Revision No.
314 oyster Creek Emergency Preparedness Program I
EXHIBIT 3 Notice of Temporary Exchanae of Duty
Subject:
IREO/ESO Exchange of Duty (circle one)
To:
Emergency Preparedness Manager - OC Security Manager -
OC I,
, am assigned to the Emergency Name Response Organization Duty Roster, Position Number _
as a(n)
Assignment I will be unable to fulfill my on-call assignment during the period to and have arranged with Name Home Telephone No.
Office No.
who is fully qualified to perform my duties during this period.
Signature Title Signature:
Person Accepting Duty Date:
(131901/S5)
E3-1
A er GenOYSTER CREEK Number Gen__
EMERGENCY PREPAREDNESS OEP-ADM-1319.01 An ExelonlBritish Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 4 QUALIFICATION REQUIREMENTS FOR ESSENTIAL PERSONNEL I.
On-Shift Emergency Organization A.
Satisfactorily complete and maintain required skills training and possess operators license, as appropriate, for assigned position.
B. Satisfactorily complete and maintain Emergency Preparedness Training Program requirements for position assigned.
C. Satisfactorily complete and maintain respirator qualification in accordance with Plant requirements.
D. Satisfactorily complete and maintain radiation worker training (Level II).
E. Must be active in the dosimetry system (i.e., TLD).
II. Initial Response Emergency Organization (IREO)
A.
Satisfy the prerequisites for selection and assignment to the specific emergency response position to which assigned, as specified in the Emergency Plan.
B. Must satisfy 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> response time requirement.
C. Satisfactorily complete and maintain Emergency Preparedness Training Program requirements for position assigned in the Initial Response Organization.
D. Satisfactorily complete and maintain respirator qualification in accordance with Plant requirements.
(See Exhibit 6 for essential positions requiring respirator qualifications)
E. Satisfactorily complete and maintain radiation worker training (Level II).
F. Must be active in the dosimetry system (i.e., TLD assigned).
- NOTE Exemptions to IC and II D may be granted by the Plant Manager or designee with EP concurrence from the Emergency Preparedness Manager if loss of the individual's expertise may lower the effectiveness of the EP Program.
However, the individual will not be permitted to enter an area where respirators are required.
(131901/S6)
E4-1
AmerGen.
An Exelon/Brttish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 4 (continued)
OUALIFICATION REOUIREMENTS FOR ESSENTIAL PERSONNEL III. Emeraency Support Oraanization (ESO)
A.
Satisfy the prerequisites for selection and assignment to the specific emergency response position to which assigned, as specified in the Emergency Plan.
B.
Satisfactorily complete and maintain Emergency Preparedness Training Program requirements for the position assigned in the Emergency Support Organization.
(131901/S6)
E4-2
Number AmerGen.
An Exelon/Brttish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 (EXAMPLE)
EXHIBIT 5 DRILL EXEMPTION LIST DRILL DATE:
COMPANY:
DEPARTMENT:
TKey Card Slot NAME (last, first)
SOC. SEC. #
Reason i
I I1 I-1 i1 i
I 4II4-1
_ -I.
4I j
4I 1
I II NOTE All required information must be completed prior to being submitted for approval.
Requested by / Date (Dir, Mgr, or Supv)
Approved by I
Date (Dir, -
Ops & Maintenance)
Plant Manager cc: Security Emergency Preparedness (131901/S7)
E5-1
't._T A Amer OYSTER CREEK Number G____en_
EMERGENCY PREPAREDNESS OEP-ADM-1319.01 An ExelonlBritish Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 EXHIBIT 6 Emergency Response Organization Essential Positions
- 101 Operations Coordinator
- 102 ECC Communications Coordinator
- 103 ECC Communicator
- 104 ECC Communicator 201 Emergency Director 202 E.D. Assistant 203 Rad. Assessment Coordinator 204 Radiological Engineering Support 205 TSC Coordinator 206 TSC Engineer (Mech) 207 TSC Engineer (Elec) 208 TSC Engineer (I&C) 210 Core Engineer (Tech Functions)
- 301 OSC Coordinator
- 302 Emergency Maintenance Coordinator
- 303 Radiological Controls Coordinator 304 Chemistry Coordinator 306 Security Coordinator 501 Emergency Assembly Area Coordinator 601 Emergency Support Director 602 ESD Assistant 603 Group Leader R&EC 604 Public Information Representative 605 EOF Communications Coordinator 606 EOF Communicator 607 EOF Communicator 608 Tech Support Representative 609 Group Leader -
Admin Support 610 Emergency Preparedness Representative 612 PI Tech Rep/Com 801 Env. Assess. Coordinator 802 Met/Dose Assessment Coordinator 910 Media Center Lead/Com 911 Media Center Advisor/Com 912 PI Tech Rep/Com 913 PI Rep/Comi
- Indicates respirator qualifications required (131901/S8)
E6-1
An' Gen OYSTER CREEK Number U
EMERGENCY PREPAREDNESS OEP-ADM-1319 01 An Exelon/Bnbsh EneTgyCompany IMPLEMENTING DOCUMENT
_D_
Title Revision No.
Oyster Creek Emergency Preparedness Program 14 EXHIBIT 7 Emergency Response Organization Supplemental Positions 250 TSC Communications Coordinator 253 Technical Assistant 350 Maintenance Team Coordinator 351 Emergency Maintenance Electrical 353 OSC Communications Coordinator 354 OSC Communicator (Operations) 450 Rad/Env. Survey Team A Leader 451 Rad/Env. Survey Team A Assistant 452 Rad/Env. Survey Team B Leader 453 Rad/Env. Survey Team B Assistant 650 EOF Tech Support Staff 651 EOF Tech Support Staff 652 EOF Tech Support Staff 653 Admin Support Staff 654 Materials Management Coordinator 658 Computer Eng.
952 JIC Admin./Communicator (131901/S9)
E7-1
AmerGenl An Exelon/Bntislh EneTgy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 EXHIBIT 8 Software Confiquration Control Chanqe Reguest
- 1.
Software/Source Code to be Changed:
- 2.
Requested Change:
- 3.
Responsible Point of
Contact:
- 4.
Concurrence for Change Request YES
/
NO Sig.
Date_
If NO an explanation should be provided to requesting party, If YES proceed with request.
- 5.
Responsible Change Party:
5.1 Description of Change:
5.2 Method of Verification and Validation:
- 6.
Responsible Reviews:
- 7.
Emergency Preparedness Approval
_itleI Approval Signature
/
Title
/
Lia Le (131901/SlO)
E8-1
Am G
OYSTER CREEK Number AnMerg enCmEMERGENCY PREPAREDNESS OEP-ADM-1319. 01 An Exelon/Etish Energy Company IMPLEMENTING DOCUMENT Title Revision No.
Oyster Creek Emergency Preparedness Program 14 EXHIBIT 9 Duty Roster Placement of Personnel
- 1.
Responsible management listed in Exhibit 2 will notify the Duty Roster Coordinator of an anticipated vacancy, duty roster change or person to be removed from the roster.
- 2.
Responsible management identifies personnel replacement to Duty Roster Coordinator.
- 3.
Duty Roster Coordinator checks prerequisites of duty position with personnel qualifications.
If personnel are qualified proceed with this process.
If personnel are NOT qualified, determination will be made on a case by case basis with the responsible management to gain the necessary training to qualify the person in the position.
- 4.
Duty Roster Coordinator will schedule and/or conduct the necessary class or classes.
Provide new roster member with duty roster packet.
- 5.
Duty Roster Coordinator will, if necessary, coordinate completion of qual card and/or drill.
- 6.
Duty Roster Coordinator will notify responsible management that individual is qualified to assume duty roster position and if necessary grant removal of outgoing roster personnel.
- 7.
Duty Roster Coordinator will update the Dialogic System and lotus notes EP roster database to add/move personnel into new position.
Use Exhibit 10 for update information.
- 8.
Individual notified of exact duty roster placement by the Duty Roster Coordinator.
(131901/Sll)
E9-1
AmerGen An Exelon/British EneTgy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING DOCUMENT Number OEP-ADM-1319.01 Title Revision No.
Oyster Creek Emergency Preparedness Program 14 EXHIBIT 10 Lotus Notes Duty Roster Database Information NAME EMPLOYEE EST. REPORTING TIME TO ERF FROM HOME SOCIAL SECURITY #-
HOME BASE #
SITE ADDRESS WORK PHONE #
HOME PHONE #
BEEPER #-
CELL #
EP OFFICE TO FILL IN TEAM #
TRAINING/QUALIFICATION COMPLETE DATE DUTY ROSTER START DATE SUPERIOR/MANAGER POSITION #
(131901/S12)
E10-1
AmerGen An Exelon/Bntish Energy CoMpany OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 Title Usage Level Revision No.
24 THE TECHNICAL SUPPORT CENTER 2
Prior Revision 23 incorporated the following Temporary Changes:
N/A This Revision 24 incorporates the following Temporary Changes:
N/A List of Pages 1.0 -
6.0 El-l to El-20 E2-1 E3-1 to E3-4 E4-1 to E4-2 E5-1 to E5-2 E6-1 E7-1 E8-1 to E8-2 E9-1 to E9-2 E10-1 to E10-6 E11-1 to E11-3 E12-1 E13-1 to E13-4 E14-1 E15-1 to E15-2 E16-1 E17-1 E18-1 E19-1 E20-1 E21-1 NON-CONTROLLED This Document Will Not Be Kept Up To Date DCC Oyster Creek (EPIP26) 1.0
AmerGen.
An Exelon/lBrtish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 DOCUMENT HISTORY REVISION DATE ORIGINATOR DESCRIPTION OF CHANGE 11 12/94 A. Smith Update GPUN/NRC response interface criteria per NUREG-1471. Add Exhibit 15 for media access during emergencies.
12 02/95 A. Smith Provide guidance for Media access during Security driven events and add current time of events statement to Exhibit IF.
13 06/95 A. Smith Update facility titles and changes to facility locations due to elimination of trailer complexes.
Delete Energy Spectrum as an alternate location for AEOF. Also renumber pages to eliminate blank page.
14 11/95 T. Blount Corrects typo's, upgrade and modify ED Deviation Authorization Form based on feedback.
15 10/96 T. Blount Change PAR guide and Logic diagram to make Evacuation Preferred recommendation. Deleted reference to AEOF based on Rev. 11, E Plan change.
Deleted TSC Layout diagram since it is normally set up.
16 06/97 A. Smith Reflect recent improvements in Technology and incorporate communicator activities from EPIP-OC-
.04.
17 08/98 A. Smith Improve & clarify ED Assistants first step on checklist. Reword press release reviews for ED Assistant to be consistent with EPIP-OC-.25. Which is less ambiguous. Make Tech. Assistants checklists responsibilities instead of check offs.
18 02/99 A. Smith EPIP-COM-.44 and EPIP-COM-.45 have been changed to Oyster Creek site specific procedures and the new numbers are EPIP-OC-.44 and EPIP-OC-.45 (reference EP changes98-021 & 98-022) 19 05/99 A. Smith Revise the public information process.
Change reporting of Tech Assistant to the ED instead of Comm. Coord.
20 10/99 A. Smith Clarify Core Eng. reporting to ECC then TSC.
21 DOS A. Smith Change references from GPU to OCNGS.
Correct titles & typos; remove media checklist; 22 11/00 A. Smith clarify 50.54 format; clarify GOS/CRO relationship for initial OSC Coord.
Revised Exhibit 1 regarding personally providing 23 06/01 R. Finicle the PAR to the Senior State Official at the State EOC.
A new exhibit, Exhibit 21 "PAR Notification Form" has also been added.
Pg. E-11 1.5 Delete reference Trailer 300 Pg. E-12 2.1.1 Note Added comment regarding recommendations of KI 24 03/03 M. Chanda Pg. El-14 Exh. IC Revised diagram to include KI and abnormal release logic paths PG. E2-1 Exh. 2 Reworded ECC Communications (EPIP26) 2.0
AmerGen An Exelon/Bntish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 Coordinator paragraph for clarity regarding being licensed.
Pg. E3-2 Exh. 3 Changed 1.9 from "Ensure one set of' to 'Ensure appropriate' Pg. E8-1 Exh. 8 Clarified 7.0 regarding issuance of self-readers at discretion of RAC Pg. E13-1 Exh. 13 Changed wording of 2. to be consistent with 10CFR50.54 (x)
Pg. E21-1 Exh. 21 Added "This is a Drill, & "This is an Actual Emergency' Added thyroid backing recommendation in "Initial PAR,
& "Expansion of PAR' (EPIP26)
- 3. 0
OYSTER CREEK Number Amer en-EMERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Bntisb EnergyCompany IMPLEMENTING PROCEDURE I
I Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 1.0 PURPOSE 1.1 This procedure provides for the activation, operation, deactivation, and evacuation of the Technical Support Center (TSC).
2.0 APPLICABILITY/SCOPE 2.1 This procedure applies to TSC personnel.
3.0 RESPONSIBILITIES 3.1 The Initial Response Emergency Organization Emergency Director (ED) is responsible for completing Exhibit 1 and implementing Exhibit 9 and 21 as appropriate.
3.2 The ED Assistant is responsible for assisting in completing Exhibit 1.
3.3 The Tech Support Center Coordinator is responsible for completing Exhibit 3.
3.4 The Tech Support Engineers are responsible for completing Exhibit 4 and 5.
3.5 The Chemistry Coordinator is responsible for completing Exhibit 6.
3.6 The Radiological Assessment Coordinator is responsible for completing Exhibit 7.
3.7 The Radiological Assessment Support Engineer is responsible for completing Exhibit 8.
3.8 The Core Engineer is responsible for implementing Exhibit 14.
(EPIP26)
- 4. 0
AmerGen An ExelonlBrttsh Energy Companry OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 1-Title THE TECHNICAL SUPPORT CENTER Revision No.
24 4.0 PROCEDURE 4.1 Initial Response Emergency Organization (IREO) personnel assigned to the Technical Support Center (TSC) will report to the TSC when they are notified of activation of the IREO and perform the responsibilities identified in their assigned exhibits to this procedure and as requested by their emergency organization supervisors.
5.0 REFERENCES
5.1 2000-PLN-1300.01 OCNGS Emergency Plan.
5.2 OEP-ADM-1319.02, "Emergency Response Facilities and Equipment Maintenance' 5.3 EPIP-OC-.01, "Classification of Emergency Conditions" 5.4 EPIP-OC-.27, "The Operations Support Center" 5.5 2000-ABN-3200.30, "Control Room Evacuation" 5.6 1820-IMP-1720.01, "Emergency Communications Implementing Procedure" 5.7 EPIP-OC-.03, "Emergency Notifications" 6.0 EXHIBITS 6.1 Exhibit 1
6.2 Exhibit 6.3 Exhibit 6.4 Exhibit 6.5 Exhibit 6.6 Exhibit 6.7 Exhibit 6.8 Exhibit 6.9 Exhibit 1, Emergency Director Checklist.
1A, Emergency Director Turnover Checklist.
1B, Protective Action Recommendation Guide.
1C, Oyster Creek PAR Logic Diagram.
1D, Emergency Director Responsibilities.
1E, NRC Emergency Response Interface Criteria.
2, Control Room Evacuation.
3, TSC Coordinators Checklist.
4, TSC Communications Coordinator Checklist.
(EPIP26) 5.0
AmerGen -
An Exelon/Britsh EneTgy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 I
Title THE TECHNICAL SUPPORT CENTER Revision No.
24 6.11 6.12 6.13 6.14 6.15 6.16 6.17 6.18 6.19 6.20 6.21 6.22 6.23 6.24 6.25 6.26 6.27 6.28 Exhibit 5, TSC Engineers Responsibilities.
Exhibit 5A, TSC Technical Assistant Responsibilities.
Exhibit 6, TSC Chemistry Coordinators Checklist.
Exhibit 7, TSC Radiological Assessment Coordinators Checklist.
Exhibit 8, TSC Radiological Assessment Support Engineer Checklist.
Exhibit 9, Press Release Approval Guidance.
Exhibit 10, Plan for Storage and transfer of Contaminated Water.
Exhibit 11, Relocation of the TSC.
Exhibit 12, Alternate Emergency Response Facilities.
Exhibit 13, Emergency Director Authorization Form for Deviations from Requirements.
Exhibit 14, Core Engineers Responsibilities.
Exhibit 15, Site Access Policy for Media During Emergencies.
Exhibit 16, Emergency Shift Schedule.
Exhibit 17, HiFax Log.
Exhibit 18, Communications Log.
Exhibit 19, Emergency Message Form.
Exhibit 20, Media Access Briefing Form.
Exhibit 21, PAR Notification Form (EPIP26)
- 6. 0
OYSTER CREEK Number AueruesD EERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/lrttish Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1 Emergency Director's Checklist NOTE The Emergency Director may initially report to the ECC to assess plant status. He may assume ED duties in the ECC but should activate the TSC once relocated to it in a timely manner. The ED Assistant will assist with the completion of this checklist but may not assume ED responsibility as delineated in Exhibit 1D.
Initials 1.0 Activate the TSC by performing these steps:
1.1 ED Assistant (EDA) has confirmed that the following areas are functional (Areas need not be 100% activated to be considered "functional"). Once the following areas are functional inform the ED that the center is ready to be activated and receive him if not already in TSC.
Technical Support Radiological Assessment Communications link to Control Room and OSC 1.2 The ED will complete Exhibit 1A of this procedure by obtaining a turnover from the Shift ED (GSS/SSM). This may be done in the Emergency Control Center, face to face, or may be done from the TSC by phone.
1.3 Brief the TSC staff including NRC (if available).
1.4 Once the above steps have been completed, inform the Shift ED that you are ready to assume your position as ED and will take over ED responsibilities (Exhibit iD contains these for reference).
1.5 Announce to the TSC staff that you are the ED, the TSC is activated and will assume Site Command and Control and off site notifications if appropriate.
Notify site protection security supervisor that the TSC is activated.
1.6 Review all press releases related to the emergency that have been approved for release by the Shift ED. Only the ED can approve.
1.7 Log TSC Activation time in ED Log.
(EPIP26/S3)
E1-1
AmerGen-An Exelon/Bnbsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 I~
Title THE TECHNICAL SUPPORT CENTER Revision No.
24 EXHIBIT 1 Emergency Director's Checklist (cont'd)
Initials 2.0 TSC Operations 2.1 TSC information exchanges should take place periodically (approximately one every hour) with NRC (if available), RAC, Technical Support Coordinator, Technical Assistant, ED Assistant, EAA Coordinator and other staff as necessary. Log briefing time and synopsis of briefing in ED Log for each occurrence.
2.2 EDA or designee to maintain the ED's log and track assigned action items.
2.2.1 Action items resulting from ED assignments shall be logged and tracked, and their disposition should be discussed periodically. The rolling white board or the PC may be used to display Action Items.
2.3 If the ED leaves the TSC for any reason, as the ED assistant, assume the person-in-charge until the ED returns.
NOTE 1 This does not include assuming ED responsibilities (see exhibit lD for reference).
NOTE 2 Interrupt the ED Conferences or phone calls to inform him of major plant changes or as other conditions warrant.
2.4 EDA to brief NRC and provide liaison.
2.5 When the EOF is activated the ESD will seek an initial briefing.
There after the ED should periodically brief the ESD approximately hourly or as conditions change. The ESD may take this briefing with his staff (and NRC/BNE) via a speaker phone.
NOTE These briefings shall be general in nature. Technical discussions should be conducted between the TSC and EOF engineering staff to ensure accuracy.
2.6 EDA is point of contact for NEI or EPRI or INPO.
(EPIP26/S3)
El-2
AmerGenl An Exelonf8ritsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS TMD7-MVrTWG PROCE!DTTRE Number EPIP-OC-.26 x
Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1 Emergency Director's Checklist (cont'd)
Initials 2.7 EDA directs efforts as appropriate for the following groups:
Communicates through the ECC and TSC communications coordinators.
Security through the Security Shift Commander.
Emergency Assembly Area through Security or the EAA coordinator.
2.8 Ensure that any TSC or Security teams are tracked by the OSC.
2.9 Review, as appropriate, Exhibit 1E, NRC Emergency Response Interface.
3.0 Site ED Page 3.1 Periodic briefings (hourly or when major changes in plant status have occurred) should take place using the ED page system. This system goes to all on-site Emergency Response Facilities (OSC, ECC, Main Gate, North Gate, TSC).
4.0 Press Releases (If not yet assumed by ESD) 4.1 Press releases should be issued within approximately one hour from the time that a major plant event has occurred. "Draft" press releases shall have a timely review. Refer to Exhibit 9 for additional guidance.
NOTE Pre-approved boiler plate press releases are contained in Procedure 1820-IMP-1720.01, Attachment 1.
Boiler plate information need not have the ED/ESD approval.
4.2 Once the Governor has declared a "state of emergency", ensure all OCNGS press releases are provided to the state police representative at the Media Center for review and agreement.
(EPIP26/S3)
El-3
OYSTER CREEK Number eRGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Bntisl Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1 Emergency Director's Checklist (cont'd)
Initials 5.0 On-site Protective Actions 5.1 If any of the off-site OCNGS Emergency Response Facilities are downwind of a radioactive release, provide for their monitoring and protection (e.g., RAA at Forked River). Exhibit 1B provides guidance.
5.1.1 If these OCNGS facilities are within sectors that were ordered to evacuate by the State, then they should be relocated to an alternate facility.
5.2 If site accountability has been ordered, ensure it is logged on PAR status board, in the ED's log, and communicated to the ESD.
Direct the C.R. to make the appropriate page announcement for accountability. If needed, provide the route to the EAA(OCAB/Warehouse).
5.3 If a site evacuation has been ordered, ensure provisions are made for providing site employees with instructions on reporting to work for the next business day. Site evacuation should be logged on PAR status board, ED's log, and communicated to ESD.
6.0 Changes to Emergency Classifications NOTE If the Communications have not been turned over to the EOF, off-site notifications must be made within 15 minutes of an emergency declaration.
6.1 Immediately notify the ECC Communications Coordinator of any changes in emergency classifications and direct the notifications be completed.
6.1.1 All notifications for on-site and off-site should be conducted from the Control Room if available, until the off-site notifications are assumed by the EOF. Upon changes in classes direct the Control Room (ECC Comm Coord) to complete the appropriate notifications. This directions satisfies the approval of such notifications.
6.1.2 If off-site notifications have been turned over to EOF, immediately confer with ESD on the need to reclassify the emergency. Remind him to ensure appropriate off-site notifications are made within 15 minutes.
6.2 Log any changes in classification in the ED Log.
(EPIP26/S3)
El-4
AmerGen.
OYSTER CREEK EMERGENCY PREPAREDNESS Number EPIP-OC-.26 An Exelon/British Energy CompanyI IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1 Emergency Director's Checklist (cont'd)
Initials 7.0 Off-site Protective Action Recommendations (PAR)
NOTE These actions shall be performed if off-site PAR responsibility is not turned over the ESD. They may be done in parallel if responsibility has been turned over.
7.1 At the Site Area Emergency, review the PAR Logic Diagram (Exhibit iC) in preparation for a General Emergency declaration.
7.2 At the General Emergency, immediately review the PAR Logic Diagram (Exhibit IC) with appropriate staff members. Develop a PAR using Exhibit 21 (PAR Notification Form) and personally covey the PAR to the Senior State official of the State EOC within 15 minutes from the GE declaration.
7.3 OCGS should attempt to obtain agreement from the NJBNE and NRC on the PAR. However, whether agreement is or is not reached, OCGS shall communicate its PAR to the Senior Official at the State EOC State within approximately 15 minutes from the time the GE was declared.
7.4 The PAR should not be included in press releases.
7.5 The ED should ascertain from the Senior State Official at the State EOC what protective action has been implemented off-site
(= 45 min. after providing PAR). This should be provided to NRC via the ENS Line as required by 10-CFR 50.72 -
follow-up Notifications -
(if not done by ESD). Off-site protective action and time implemented should be logged in ED's Log.
8.0 All deviations from procedures, equipment operating limits, Technical Specifications, License, and License Conditions will be authorized and documented using the guidance in Exhibit 13.
(EPIP26/S3)
El-5
OYSTER CREEK Number Arer~en EMERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Bnt sh Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1 Emergency Director's Checklist (cont'd)
Initials 9.0 NRC Interface 9.1 The Security Plan allows that "when ever site conditions are, or may soon become, a danger to the public health and safety, certain safe guards measures may be suspended in accordance with the following requirements. The action taken is approved by the Manager of Plant Operations, Operations Group Shift Supervisor or Emergency Director. If the ED is not a licensed SRO, he/she must consult with a licensed SRO prior to authorizing the Suspension of any safeguards measures".
9.1.1 Security is able to process the NRC site response team rapidly if the ED (GSSISSM) authorizes their immediate access under the above Security Plan provision. Any such authorization should be logged.
9.1.2 If this provision is not used it will likely take 2-3 hours to train, badge and allow access to the whole NRC team. This delay will detract from the functioning of the NRC Team but is clearly at the judgment/discretion of the ED.
NOTE An alternative to waiving access requirements is to arrange for escort.
9.1.3 NRC immediate access under this Security Plan provision is meant to provide access to emergency centers only, not site wide access, RWP access or approve respiratory protective equipment use.
9.2 Brief the NRC upon arrival and determine if the Senior NRC person is the Site Team Leader or Director, Site Operations (see Exhibit 1E for reference).
9.3 NRC directives can only be received by the ESD (or in the ESD's absence, the ED). NRC should be requested to provide all directives in writing.
(EPIP26/S3)
El-6
A OYSTER CREEK Number Amerien EERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Eritish Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1 Emergency Director's Checklist (cont'd)
Initials 9.4 As time permits, discuss with the senior NRC person in the TSC the OCNGS emergency organization. Discuss that the ED oversees site related activities, maintaining general (not detailed) cognizance of reactor operations and that while the ESD oversees the whole emergency effort, he concentrates on off site interfaces and issues.
9.5 If media access to the site is requested, refer to Exhibit 15,
'Site Access Policy for Media During Emergencies".
10.0 Long-term Recovery 10.1 Refer to Procedure EPIP-OC-.45 for Long-term Recovery and discuss its implementation with the ESD.
10.2 If a General Emergency is in effect, OCNGS will not de-escalate to a lower level of emergency. The only option is to go into Long-term Recovery and this transition shall not occur until all off-site protective actions have been completed and the State has been informed.
10.3 Establish long term staffing requirements and prepare appropriate watch bill.
11.0 Control Room Evacuation 11.1 Review Exhibit 2A for guidance.
12.0 TSC Relocation 12.1 Should the TSC be or become unavailable (e.g. due to Fire, Security Event, etc.) refer to Exhibit 11 which provides guidance for the establishment of TSC functions in alternate locations.
12.2 A description of evacuation preplanning for other Alternative Response Facilities is provided in Exhibit 12.
Name Date Time_
(EPIP26/S3)
El-7
AmerGenm An Exelon/Bribsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 (Page 1 of 3)
EXHIBIT IA EMERGENCY DIRECTOR TURNOVER CHECKLIST NOTE This form may be completed by ED in the Control Room or via phone. It may be used to brief NRC representatives upon their arrival.
EMERGENCY CLASSIFICATION DATE/TIME OF DECLARATION UNUSUAL EVENT ALERT SITE AREA EMERGENCY GENERAL EMERGENCY
- Reactor Power at time of event BRIEF DESCRIPTION OF THE EMERGENCY CURRENT PAR STATUS * (Required for General Emergency)
STATUS OF ACCOUNTABILITY/ON-SITE PROTECTIVE ACTIONS PRESENT STATUS OF PLANT/TIME OF DATA:
DATE:
AT POWER (
%)
Hot Standby Hot Shutdown Cooling down (describe cooldown mode)
(EPIP26/S3)
E1-8
AmerGen.
An Exelon/British EneTgy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 I
Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1A (Continued)
EMERGENCY DIRECTOR TURNOVER CHECKLIST (Page 2 of 3)
Estimated time to 'STABLE' plant conditions Did reactor trip?
Did ECCS activate?
Is off-site power available?
Are both Diesel Generators operable?
Are Diesels Running?
- 1 YES -
NO Are the Station Blackout CT's Available?
Is fuel integrity maintained?
Is containment integrity maintained?
If no, specify hours YES -
NO YES -
NO YES -
NO YES -
NO
- 2 YES - NO YES -
NO YES -
NO YES -
NO Do you suspect there is a release (monitored or unmonitored) in progress?
If yes, specify pathway:
NO YES N/A Is release Plume dispersion Details:
AIRBORNE RELEASE ELEVATED LIQUID RELEASE GROUND UNKNOWN N/A Are there any abnormally high implant radiation levels?
Specify location Are there any personnel injuries?
Provide status Were there any news releases issued?
Specify YES -
NO YES -
NO YES -
NO (EPIP26/S3)
E1-9
AmerGen.
An Exelon/Bittsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 (Page 3 of 3)
EXHIBIT IA (continued)
EMERGENCY DIRECTOR TURNOVER CHECKLIST Are there any open technical issues?
YES -
NO Specify News releases issued ATTACHED NOTES:
When finished sign below:
Emergency Director Time Date (EPIP26/S3)
E1-10
OYSTER CREEK Number AmerGen ERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Brvtfsh EnergyCompany IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1B PROTECTIVE ACTION RECOMMENDATION GUIDE 1.0 On-site 1.1 Inform the OSC Coordinator of personnel who were dispatched in support of emergency before the OSC was activated.
1.2 Relocate site personnel from areas of hazard or where the dose is projected to exceed 1000 mRem Total Effective Dose Equivalent (TEDE). Consult RAC.
1.3 Evacuation of any area, site accountability, and site evacuation may be ordered at the discretion of the Emergency Director.
Accountability is required at the declaration of a Site Area Emergency, or at the discretion of the ED in accordance with the E-Plan.
Site Evacuation is required at the declaration of a General Emergency, or at the discretion of the ED in accordance with the E-Plan.
NOTE During Drills do not initiate Site Accountability or Site Evacuation without Drill Controller agreement.
During Real Events accountability and evacuation shall be conducted in accordance with the E-Plan. If the Main Gate is evacuated, accountability can not be conducted.
1.4 Consider protective actions such as:
securing ventilation, access control, Safety Department support.
1.5 Consider protective actions such as:
leaving the site, sheltering, or evacuation to an assembly area for OCAB, Forked River Site, Combustion Turbine Site and the Southern Area Stores Warehouse. If action is necessary, personnel may be informed by the following mechanisms:
1.5.1 Contact Security Shift Supervisor to make a page announcement on the Forked River Site and Trailer 300.
AND 1.5.2 Direct Security Shift Supervisor to dispatch a patrol to the affected areas to direct personnel to take the prescribed protective actions. Consider Security manpower requirements when taking this action.
OR 1.5.3 Direct available personnel (e.g., from OSC) to go to the affected areas to direct personnel to take the prescribed protective actions.
(EPIP26/S3)
El-11
OYSTER CREEK Am er~en EMERGENCY PREPAREDNESS An Exelon/Brttish Energy Company IMPLEMENTING PROCEDURE Title THE TECHNICAL SUPPORT CENTER Number EPIP-OC-.26 Revision No.
24 EXHIBIT lB EXHIBIT 1B (cont'd)
PROTECTIVE ACTION RECOMMENDATION GUIDE 1.6 Consider use of KI if personnel have been exposed to significant radioactive Iodine. Consult RAC and Medical representative. EPIP-OC-.44 provides guidance.
1.7 Consider the need for security to control access to hazardous areas outside the RCA or outside the Protected Area.
1.8 Emergency Exposure Guidelines A. Voluntary Life Saving Actions B. Corrective Actions
- 1. Total Whole body dose (TEDE)
- 2. Lens of the eye
- 3. Total organ dose No Pre-established limit Administrative Guidelines 10 Rem 30 Rem 100 Rem 2.0 Off-site 2.1 At the General Emergency, review the Protective Action Logic Diagram and provide PAR to the State within 15 minutes of declaring the General Emergency.
2.1.1 The guidance provided by the NRC for a Protective Action Recommendation at a General Emergency is Evacuation 2 miles in 360 degrees and 5 miles downwind.
Shelter all other non-affected areas of the 10 mile EPZ.
NOTE If PAGs are exceeded, or are expected to be exceeded, beyond th 10 mile EPZ, assess the impact on an Ad Hoc Basis (i.e. Field Monitoring Team Data or Hand Written Contingency Calculations),
and provide recommendations as appropriate.
Recommend thyroid blocking (KI) to the general public in any area of the EP2 in which the projected child thyroid CDE is equal to or greater than 5 Rem.
2.1.2 Under certain circumstances it is permissible to recommend Sheltering if it is known that Sheltering WILL PROVIDE GREATER PROTECTION.
Le 2.1.2.1 This would most likely occur only for short (puff) release periods that are less than 1.5 Hrs. (which substantially shorter than the evacuation time).
is 2.1.2.2 There must be strong assurance that there is definite control of the release and termination of the release by the positive actions of the emergency responders actions during the release process (such as Containment Venting).
El-12 (EPIP26/S3)
AmerGen.
An Exelon/British Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS TMPTLW1ERMrTING PROC)EDURE Number EPIP-OC-.26 Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 1B (cont'd)
PROTECTIVE ACTION RECOMMENDATION GUIDE 2.1.3 Sheltering may be the protective action of choice, if rapid evacuation is impeded by:
a) severe environmental conditions-e.g. severe weather or floods; b) physical constraints to evacuation-e.g. inadequate roads NOTE The information in 2.1.3 a & b MAY ONLY BE AVAILABLE from previous discussions with New Jersey Office of Emergency Management or New Jersey Bureau of Nuclear Engineering Personnel.
2.2 During a Site Area Emergency, Protection Action Recommendations should not be immediately necessary, however, the PAR Logic Diagram should be reviewed.
2.3 Off-site protective actions should not be required during an Unusual Event or Alert.
(EPIP26/S3)
El-13
(
Exhibit 1C PAR LOGIC DIAGRAM CHANGE Procedure (
Rev. 24
-26 SITE AREA EMERGENCY IS DECLARED l
REVIEW PAR LOGIC DIAGRAM IN PREPARATION FOR A POTENTIAL GENERAL EMERGENCY DECLARATION AND PROTECTIVE ACTION RECOMMENDATIONS k
PI H
I PROGRESSS YES Fez 5REM CDE
\\L THRI NO
NO NO KI YES EVACUATE A 2 MILE RADIUS AND 5 MILES DOWNWIND UNLESS IT IS KNOWN THAT SHELTERING WILL OFFER GREATER PROTECTION SHELTER ANY AREAS OF THE 10 MILE EPZ NOT EVACUATED NOTE IF PAGs are exceeded, or are expected to be exceeded, beyond the 10 Mile EPZ, assess the impact on an AD HOC Basis (i.e. Field Monitoring Team Data or Hand Written Contingency Calculations, and provide recommendations as appropriate.
(See Exhibit lb Section 2.1.1 through 2.2.3)
KI NO EVACUATE A 2 MILE RADIUS AND 5 MILES DOWNWIND UNLESS IT IS KNOWN THAT SHELTERING WILL OFFER GREATER PROTECTION SHELTER ANY AREAS OF THE 10 MILE EPZ NOT EVACUATED NOTE IF PAGs are exceeded, or are expected to be exceeded, beyond the 10 Mile EPZ, assess the impact on an AD HOC Basis (i.e. Field Monitoring Team Data or Hand Written Contingency Calculations, and provide recommendations as appropriate.
(See Exhibit lb Section 2.1.1 through 2.2.3)
OYSTER CREEK Number Amer~en EMERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Bitilsh EneTgy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT ID EMERGENCY DIRECTOR RESPONSIBILITIES The ED is vested with certain authority and responsibilities that may not be delegated to a subordinate.
Included are:
A.
Approving and directing official notifications to off-site agencies.
B.
Approving and directing information releases to the media.
ED/ESD approval is not required for public announcement of formal emergency declaration and changes of emergency classifications, or other pre-approved boiler plate news releases as contained in Procedure 1820-IMP-1720.01, Attachment 1.
C.
Approving and, if possible, personally conveying appropriate Protective Action Recommendations to the New Jersey Office of Emergency Management.
D.
Serve as principle "point of contact" for receiving NRC directives.
0 E.
Classification of an emergency event.
F.
Directing on-site evacuation at the Alert or lower level emergency classification based on potential hazard to nonassigned personnel.
G.
Authorizing emergency workers to exceed 10 CFR 20 Radiation Exposure Limits in accordance with Exhibit lb.
H.
Approving and directing deviation from established operating procedures, normal equipment operating limits, or technical specifications during attempts to control the plant emergency/or during a declared National Security Emergency.
NOTE: For National Security Emergencies, the following conditions must be met.
- 1. When this action is immediately needed to implement national security objectives as designated by the National Command Authority through the NRC.
and
- 2. No action consistent with license conditions and technical specifications that can meet national security objectives is immediately apparent.
(EPIP 26/S3)
E1-15
OYSTER CREEK Number Amer~esMERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Brlisl Energy Company IMPLEt4NTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT iD (continued)
EMERGENCY DIRECTOR RESPONSIBILITIES NOTE: In essence, no one below a licensed SRO individual can make the decision to depart from the license. However, if a more senior manager is present (i.e., Emergency Director) even though he may not posses an SRO license, the decision authority would be passed to him as a higher authority in the chain of command. The licensed SRO shall provide his best judgment to the ED for his consideration. Beyond that, the SRO shall follow the orders of his supervisor. It is imperative that the Emergency Director consult the SRO, and the Technical Support Center to the fullest extent practicable in arriving at a decision to deviate from prescribed procedures. However, Emergency Operating Procedures should generally not be deviated from. If the decision is made to depart from licensee conditions or technical specifications, notify the NRC before taking such actions, if time permits or if time does not permit then within one hour.
When the Emergency Support Director (ESD) arrives at the EOF and declares himself to be ready to assume that role, he will assume overall responsibility for management of the response to the accident and recovery operations. With the activation of the Emergency Support Direction function, the ESD specifically will assume decision authority for Items A, B, C, and D. However, decision authority for Items E, F, G, and H will be retained by the ED. Decisions on all of the listed actions normally will result from close and continuous consultation between the ED and the ESD, and it shall be the responsibility of the ED to ensure the ESD is provided with the necessary information to arrive at timely and appropriate decisions. In the special case of event classification, the ESD shall retain the prerogative to overrule the ED if, in the judgment of the ESD, uncertainty or other considerations exist to the extent warranting classification of higher level of emergency than that classified by the ED.
(EPIP 26/S3)
El-16
OYSTER CREEK Number AmerGen EMERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Brttish Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT lE NRC EMERGENCY RESPONSE INTERFACE CRITERIA This is a synopsis of the NRC emergency response process as it applies to OCNGS.
In essence, directives from the NRC must come from the NRC Director (typically, the NRC Chairman) or from the NRC Director of Site Operations (typically, the NRC Regional Administrator). Such advice or directive can only be communicated to the Emergency Director (the Emergency Support Director once the EOF is activated). If a directive order is issued by the NRC Director or Director of Site Operations, the ED/ESD should request written confirmation which spells out the specific nature of the directive.
While NRC advice may be challenged by the ED or ESD, directives must be complied with.
With respect to Protective Action Recommendations for the public, the NRC may either endorse the OCNGS recommendation or opt to recommend a different one. The ED/ESD is encouraged to include the NRC and State representatives in the Protective Action Recommendation discussions in order to arrive at a mutually agreeable recommendation. In the event that the NRC opts to recommend a different recommendation, they will communicate directly with the State. Their recommendation, like the utility recommendation, will be considered by the State in the development of a Governor directive.
Upon arrival of the NRC, the ED/ESD should:
Verify who is the senior NRC person in charge Ask the senior NRC person to inform the ED/ESD when the position of Director Site Operations is assumed and whether the responsibility to issue directives is included.
Request that the NRC keep OCNGS informed of all substantive information exchanges between the NRC and the slate.
Request the NRC provide all directives in writing.
SYNOPSIS - NRC EMERGENCY RESPONSE NOTE Review the following as time permits and/or if the NRC is expected to respond.
Revision 2 to NUREG-0728, supplemented by NUREG-0845 and NUREG-1471, describes the manner in which the NRC will respond to an incident and provides criteria for making preplanned response decisions. They provide procedural guidance, describe the functions related to NRC emergency response, and define procedures for responding to the following NRC modes of operation.
(EPIP 26/S3)
E1-17
OYSTER CREEK Number AmerGen -
EMERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/Brtish Energy Company TMPT.LM.TING PROCEDURE I
Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT lE NRC EMERGENCY RESPONSE INTERFACE CRITERIA Each mode defines the scope of NRC activities related to a particular level of emergency response in ascending order of degree of involvement to deactivation. The various modes are characterized as follows:
- 1. Normal mode - Normal activities designed to maintain readiness.
- 2.
Standby mode -
Regional office activates the Incident Response Center (IRC with an appropriate staff and NRC Headquarters Operations Center staffed by a standby team.
- 3.
Initial activation - NRC Operations Center is staffed by a response team, the Regional IRC is fully activated and a site team is dispatched under the leadership of the Regional Administrator, normally designated as Director of Site Operations (DSO).
- 4.
Expanded activation - Focus on NRC response operations is shifted to the site. DSO is designated primary spokesman for the NRC and may be empowered with directive authority by the Chairman of the Nuclear Regulatory Commission.
- 5.
Deactivation -
Follow-up activities (e.g., reviews, investigation, and recovery operations).
The particular mode assumed by the NRC will be dependent upon licensee event classification
\\~-'
and independent NRC perception of relative severity of uncertainty of accident conditions."
NRC ADVICE The NRC may offer advice or assistance to the Licensee during an emergency, or may respond to Licensee requests for advice or assistance. This may involve diagnosis of critical problems, development of proposed remedial courses of action, and proposals to implement additional precautionary measurers. The NRC is also prepared to direct that certain actions be taken if, after thorough discussion with the Emergency Director (the Emergency Support Director once the EOF is activated) it is decided that such direction is required. In the event that such action is taken by the NRC Director or the NRC Director of Site Operations, the ED/ESD should request written confirmation which spells out the specific nature of the directive.
Directives will be communicated directly to the ED/ESD from the NRC Director (NRC Chairman) or from the NRC Director of Site Operations (DSO), typically the Regional Administrator, once appointed and empowered to do so.
Several important concepts govern the NRC in providing advice, assistance, or direction.
They are:
- a.
The Licensee is at all times responsible for mitigating the consequences of the incident.
- b.
Although the NRC could issue formal orders to the Licensee to take certain measures and to monitor implementation, ".
licensee continues to make other key operational decisions and to operate and manage the facility.
- c.
The NRC must have a single voice when advising or directing the Licensee.
- d.
The ED/ESD has the option to accept or challenge NRC advice.
(EPIP 26/S3)
E1-18
OYSTER CREEK Number Amer'eu.
EMERGENCY PREPAREDNESS EPIP-OC-.26 An Exelon/BrTtsh Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT lE (continued)
NRC EMERGENCY RESPONSE INTERFACE CRITERIA At no time will advice or direction come from both the Director and DSO and the Licensee will always be kept apprised of who is empowered to exercise authority as the NRC Spokesman. All other NRC personnel in contact with Licensee personnel are responsible to make clear that discussions should not be construed as advice or direction but rather as a sharing or gathering of information.
NRC INPUT TO RECOMMEND PROTECTIVE ACTIONS The NRC responsibility during an emergency, as during normal operations, is to ensure that protection of public health and safety is adequate. One aspect of exercise of this responsibility is to provide Protective Action Recommendations or advice to off-site authorities. This may take the form of an NRC endorsement of a Licensee Protective Action Recommendation or the NRC may opt to recommend additional protective actions. The NRC is not involved in the process of recommending Protective Actions, the NRC may get involved if a major problem is identified with the protective actions recommended by the licensee or protective actions undertaken by the state or local government. Additionally NRC involvement may be requested by state or local officials.
NRC ORGANIZATION The attachment to the synopsis is provided for your information. This attachment depicts the site team organization and is an extract of the Region I supplement.
It defines the number of NRC personnel expected to operate in each facility and shows the lines of communications the NRC expects to use.
(EPIP 26/S3)
El-19
(
NRC SITE ORGANIZATION -
INITIAL SITE TEAM EPIP-OC-.26, REV. 24 (
I Dashed bordered boxes indicate I
I Critical Positions. Critical positions I
I constitute the minimum staff necessary I
to perform the critical NRC response functions preparatory to designation of a Director of Site Operations (DSO).
l Oirector of Site I
l Operations (0SO)
I I
I l
EOF I
I ____
EOFP Emergency Respo ns Government Public Affairs Protective Measures coordinator (SRC)
Liaison Coordinator Coordinator I
Coordinator (PHO)
I l
I l
(GLC) l I
Is I
EOF EOF I
16 --
l l
Public Affairs State EOC Asst Coordinator Coordinator State EOC XI Radiati II Reactor Safety Coordinator (RSC)
I I
EOF I
I I-_
React Operatioi 1
1 I ~-t-1 I
I Safeguard/Security Status Summary I l Coordinator (SSC)
I I
Coordinator (STSC)
I I
I I
l I
I I j EOP/TSC I
I-I-
A on Safety I
II__
tor Safety ns Coordinator
- OF/TSC I
Re-ident R7s idn.t Location of all positions is driven by the State/Licensee's Emergency Response Organization The facilities listed with these position represent the probable locations tQ Note 1: Either the PMCL Communicator or the HPN Communicator will be a critical position, not both.
Note 2. Either the ENS Communicator or the RSCL Communicator will be a critical position, not both Note 3. Safeguards/Security Assistant Coordinator is part of the Initial site Team only in safeguards/security type events.
Coordinator (RASC)l I
I X
EOP/TSC I_____
HP Specialist TiC OSC NPN Communicat(
t O PF I(See Note L--
Environmental DoseI Assessment Coordinatorli I
I EOF
-I J
~1 Dor I
-4
-I
OYSTER CREEK EMERGENCY Number AmerGen PREPAREDNESS EPIP-OC-.26 An Exelon/Biti sb BnergCorpaly IMPLEMENTING PROCEDURE
~
Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 2 CONTROL ROOM EVACUATION CR evacuation is guided by Operations Procedures. Should it be necessary Operations personnel will establish plant control via the remote shut down panels. If the CR evacuation is the initiating event, CR staff will implement their procedures and declare an Alert, activating the Emergency Response Organization. Operations Management will locate in the TSC. If the ERO is already activated, several ECC personnel will report to the TSC.
In either case guidance for integrating these resources into the TSC staff follows:
OPs Coordinator with Technical Assistant GSS/SSM, STA will require table space in back of TSC to guide operators by radio.
ECC Communicators -
to Communications Coordinator for deployment in TSC, other centers, Remote Assembly Area or home.
ECC Communications Coordinator if licensed may be of use to OPs Coord, GSS/SSM, TSC Coord, EOF or as NRC liaison.
Discuss these arrangements with the OPs Coordinator and deploy personnel accordingly.
(EPIP26/S5)
E2-1
AmerGen.
An Exelon/EBntsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 I
Title THE TECHNICAL SUPPORT CENTER Revision No.
24 EXHIBIT 3 TSC Coordinators Checklist Initials 1.0 TSC Activation 1.1 The TSC should be declared ready for the ED when the following areas are functional:
NOTE These areas need not be 100% staffed to be considered functional.
- Radiological Assessment eTechnical Support (appropriate engineering expertise) eCommunications links to Control Room and OSC NOTE The following actions should be performed expeditiously but are not necessary to declare the TSC functional.
1.2 When possible perform, or have a Technical staff member perform, a briefing of the TSC staff prior to the ED's arrival. This should provide the staff with the current emergency conditions 1.3 Ensure all required TSC personnel use the position tag board and display position tags.
1.4 Ensure the RASE has set up one entry point with a frisking station is established. Based on actual or expected emergency conditions, Rad Con will evaluate whether or not a whole body frisk is required for entry into the TSC. If a whole body frisk is required, Rad Con will post the area accordingly. Proper frisking techniques will be followed by all personnel prior to entering the TSC once the area is posted as requiring a whole body frisk.
E3-1 (EPIP26/S6)
AmerGen.
An Exelon[Britsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 pi.rrni4nn No.
Revmision No.
Title THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 3 (continued)
TSC Coordinators Checklist 1.5 Ensure the RASE has performed continuous air monitor preoperational checks and the system is operating.
1.6 Ensure the RASE has performed area radiation monitor preoperational checks and the system is operating.
1.7 Check duty board in back of TSC to determine positions not manned. Notify Security of unfilled positions and ask them to call out personnel. The following engineering disciplines should be adequately represented:
1.7.1 Mechanical Engineering 1.7.2 Electrical Engineering 1.7.3 Radiological Engineering 1.7.4 Instrument and Controls Engineering NOTE Report to the TSC Coordinator, unless needed in the ECC. If Core Engineer reports to ECC first, then the TSC Coordinator should be informed.
1.7.5 Core Engineering 1.8 Callout any additional personnel as needed. Complete staffing of this area is not necessary for TSC activation. Security through the ED Assistant can help with duty roster callouts.
1.9 Ensure appropriate Emergency Plan Implementing Procedures are available at the ED's desk, the TSC Coordinator's desk, and the RAC/Chemistry Coordinator's desk.
1.10 Ensure both PCS terminals in the TSC are functioning.
1.11 Check on PCS availability at the OSC and EOF. Attempt to help the other centers bring on-line if necessary.
1.12 Check the status of the ERDS link. If necessary, work to establish the line to the NRC.
NOTE If there is an ERDS problem it may be because the modem (located in the Computer Room) is locked up. The problem may be resolved by resetting the modem or turning it off and on.
1.13 Call Computer APPS. for additional assistance as needed.
(EPIP26/S6)
E3 -2
OYSTER CREEK EMERGENCY Number AmerGen.
PREPAREDNESS EPIP-OC-.26 An Exelon/BrSh EneTgy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 3 (continued)
TSC Coordinators Checklist 1.14 Set TSC clock to match the time on the Plant Computer System display (during drills this time may be obtained from the controller).
2.0 TSC Operations 2.1 Accept assignments from the ED. Disposition them to TSC staff and log in the TSC Coordinator's log using Lotus Notes or paper.
2.2 If at any time it becomes necessary to operate the TSC Ventilation System review the following guidance.
2.2.1 There is a continuous indicating air monitor in the TSC which will provide indication if the need for use of the TSC ventilation charcoal filters. Rad Con is also located in the TSC and can provide guidance on use of the filters.
2.2.2 TSC Ventilation System normally operates with charcoal filters bypassed.
2.2.3 The filters are controlled by a two position covered switch on the rear column in the TSC. It is labeled Emergency/Normal. The Emergency position places the charcoal filters in service. The Normal position removes the filter from service.
2.2.4 When the charcoal filters are engaged the gauge above the Control switch should be at + 0.125 inches water or greater to assure no leakage into the room.
If it is otherwise notify Radiological Controls to assess habitability and specify compensatory measures as necessary.
2.2.5 Log time charcoal filter enters and is taken out of service. This may be entered in the ED's Log.
2.2.6 Advise RAC to conduct surveys in accordance with Exhibit 8 Step 6.
2.3 Establish contact with Corporate Engineering Support and assess their status and resources. Engineering requests suited for Corporate Engineering should be sent to them, in writing if practical. Corporate Engineering will contact the TSC as soon as they are available.
2.4 Develop a shift schedule for the TSC organization Exh.
(16). The current duty roster may be used to develop this schedule. Attempt to allow adequate rest time for all shifts off duty.
(EPIP26/S6)
E3-3
OYSTER CREEK EMERGENCY merGef PREPAREDNESS An Exelon/BrItish Energy Company IMPLEMENTING PROCEDURE
~"
Title THE TECHNICAL SUPPORT CENTER EXHIBIT 3 (continued)
Number I
EPIP-OC-.26 Revision No.
24 TSC Coordinators Checklist 2.5 TSC support of site accountability.
2.5.1 Announce Site accountability to the TSC Staff and ensure that all personnel present in the TSC have key carded into the Accountability Key Card Reader.
2.6 If notified by the Security Shift Commander/designee of security computer failure, complete Steps 2.6.1 through 2.6.4.
2.6.1 Assign an individual to collect accountability cards in facility.
2.6.2 Direct individual to sort the cards into separate groups for North Gate and Main Gate.
2.6.3 Direct individual to call both Main Gate and North Gate Security with badge slot numbers within 10 minutes of initial declaration of accountability.
2.6.4 Accountability notifications completed for facility.
2.7 Should long term accident management require it, Exhibit 10 provides guidance on storage/transfer of contaminated water.
3.0 Facility deactivated by order of Emergency Director.
3.1 Documents, records, and reports delivered to Emergency Preparedness Department.
3.2 Record any equipment failures.
3.3 Refile prints and procedures as required.
3.4 Report discrepancies to the Emergency Preparedness Dept.
3.5 TSC returned to standby condition.
4.0 TSC Evacuation 4.1 Should the TSC be or become unavailable (e.g.; due to Fire, Security Event, etc.) refer to Exhibit 11 which provides guidance for the establishment of the TSC Functions in alternate locations.
NAME:
Technical Support Center Coordinator Time Date (EPIP26/S6)
E3-4
ANT.,
1>
OYSTER CREEK EMERGENCY umner
-AmerGen.
PREPAREDNESSEPPO.2 An Exelonlentsh EneTgy CoMPany IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 4 TSC COMMUNICATIONS COORDINATOR CHECKLIST INITIALS 1.0 Report to the ED Assistant and support information transmittals to ECC, OSC, EOF, BNE and NRC using Exhibit 19 or Lotus notes as appropriate.
2.0 Set the TSC clock to agree with the time displayed by the PCS. (During drills, ask the Controller) 3.0 Log appropriate activities or tasks via lotus notes or exhibit 18.
4.0 Dim the lighting in the front of the TSC to enhance data display.
5.0 Activate fax and set time in accordance with PCS Clock.
6.0 Number and log each fax transmission using Exhibit 17.
NOTE Number outgoing transmissions sequentially regardless of the type of transmission. Use location designator as part of sequential number, i.e. TSC-001, TSC-002, etc.
7.0 When the ED Assumes command and Control in the TSC, Relay Appropriate directives to the ECC Communications Coordinator Such as:
- 1. Perform Off-site Notifications
- 2. Perform On-site Notifications
- 3. Transfer Notification Responsibilities.
8.0 Ensure that communications to the NRC via NRC/ENS line are made by an individual knowledgeable of plant systems. This may require callout of additional personnel. Only one Emergency Center should provide this function at one time.
9.0 Report failed communications systems to information services for resolutions when needed have security or the group leader admin. callout information services telecommunications personnel. These individuals will work under the TSC Communications Coordinator's direction to repair phone problems in emergency centers. If they must leave the SEB to effect repairs, coordinate their movements with the OSC as a repair team. A briefing via telephone is permissible if briefing items are logged. Alternately the briefing forms could be telefaxed from OSC to TSC and back.
Report ENS or ERDS phone line problems (FTS-2000) to the NRC at (301) 816-5100.
(EPIP26/S7)
E4-1
OYSTER CREEK EMERGENCY AmerGen_
PREPAREDNESS An Exelon/Bbtsh Energy Company IMPLEMENTING PROCEDURE Title THE TEC I CAL SUPPORT CENTER Number EPIP-OC-.26 Revision No.
24 EXHIBIT 4 EXHIBIT 4 (continued)
TSC COMMUNICATIONS COORDINATOR CHECKLIST INITIALS
- 10. 0 11.0 12. 0 13.0 If the Plant Computer System fails, ensure that the ECC transmits critical plant parameters to the TSC every 15 minutes or as conditions change. The TSC should retransmit plant parameters to the EOF and OSC in as timely a manner as possible.
Upon termination of the emergency, if notification were made from the TSC ensure those agencies previously notified in EPIP-OC-.03 have been advised of the termination.
11.1 If Off-site notifications responsibility has been transferred, this responsibility should be transferred also, verify completion with appropriate Communication Coordinator.
Ensure communications equipment, supplies and procedures are replaced or returned to a ready status.
Forward all completed logs and records to the Emergency Preparedness Dept.
Signature Date TSC Communication Coord.
(EPIP26/S7)
E4-2
OYSTER CREEK EMERGENCY AmerGes "PREPAREDNESS An Exelon/Bntish EneTgy Company IMPLEMENTING PROCEDURE Title THE TECHNICAL SUPPORT CENTER EXHIBIT 5 Number EPIP-OC-.26 Revision No.
24 TSC Engineers Responsibilities 1.0 Report to the TSC Coordinator.
2.0 As requested assist the TSC Coordinator in activation, operation, and recovery of the TSC. Refer to his checklist (Exhibit 3) for guidance.
3.0 Perform and document engineering tasks as directed by the TSC Coordinator as needed provide appropriate information to the EOF or other activated centers.
4.0 Present all documentation generated during the performance of their duties to the TSC Coordinator.
5.0 As directed, assist TSC Coordinator in deactivation of TSC.
6.0 Should the TSC be or become unavailable (e.g.; due to Fire, Security Event etc.) refer to Exhibit 11 which provides guidance for the establishment of the TSC functions in alternate locations.
E5-1 (EPIP26/S8)
OYSTER CREEK EMERGENCY Number AmerGen PREPAREDNESS EPIP-OC-.26 An Exelon/Brtish Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 5A TSC TECHNICAL ASSISTANT RESPONSIBILITIES 1.0 Report to the TSC Emergency Director.
2.0 Maintain Operations Conference Line in response to calls from Operations Coordinator.
3.0 Coordinate with the ED, ED Assistant and Engineering Staff in the TSC Coordinator to provide technical support to the Ops Coordinator in the ECC pertaining to various items such as:
Equipment Failure EOP's Support 4.0 If operational data is not being provided as needed, actively solicit this data.
5.0 Monitor the Equipment Status Display System (ESDS) if available. Provide technical update on equipment status as necessary, validate and correct as needed.
6.0 Convey ED directives to the ECC through the Ops Coordinator as necessary. Maintain ED (TSC Staff) apprised of the operational status and activities taken by the ECC, Review EAL matrix periodically for applicability of classifications and changes to plant conditions.
(EPIP26/S8)
E5-2
AmerGen.
An Exelon/Bntfsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 6 TSC Chemistry Coordinator Responsibilities NOTE Chemistry Department will staff the OSC Chemistry Coordinator position first and send a Chemistry supervisor to the TSC when available.
1.0 Advise the ED and RAC on conditions related to reactor coolant chemistry including, but not limited to:
1.1 Normal chemistry sampling.
1.2 Post Accident Sampling (PASS and RAGEMS) 2.0 Coordinate with the RAC to develop source term information.
3.0 Prestage a chemistry team to obtain and analyze an effluent sample should it become necessary. This should be given the highest priority if a release begins.
4.0 Prestage a PASS team to obtain and analyze samples sh6uld it become necessary. Ensure all necessary equipment and arrangements are in place should transport of the PASS sample off-site become necessary.
5.0 Consider actions necessary to quantify all components of radiological releases. Plan a course of action which will support post accident investigation of source term released to the environment.
6.0 Should the TSC be or become unavailable (e.g.; due to Fire, Security Event, etc.) refer to Exhibit 11 for guidance.
(EPIP26/S9)
E6-1
OYSTER CREEK EMERGENCY Amer____
PREPAEEDNESS An Exelon/Britsh Energy Company IMPLEMENTING PROCEDURE Number EPIP-OC-.26 Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 7 TSC Radiological Assessment Coordinators Checklist Initials 1.0 Periodically brief the ED on radiological conditions.
In-plant radiation and contamination levels and associated protective actions.
On-site (and near site) radiological conditions and associated protective actions.
Off-site radiological conditions including dose projections and Protective Action Recommendations until relieved of this responsibility by the Environmental Assessment Coordinator (EAC).
2.0 Routinely ensure the EAC is informed of all source term information which is available.
3.0 Coordinate with the Chemistry Coordinator to develop source term information.
4.0 Maintain the meteorological and PAR status boards.
5.0 Periodically review Radiological EAL's in EPIP-OC-.01 "Classification of Emergency Conditions". Ensure that the ED is immediately notified of any situation which meets these EALs.
6.0 At the Site Area Emergency assist the ED with review of the PAR Logic Diagram (Exhibit lC). Provide route for Site Accountability to the ED that avoids/minimizes radiological hazards.
7.0 At the General Emergency assist the ED with development of a PAR (Exhibit IC). Provide route for Site Evacuation to the ED that avoids/minimizes radiological hazards.
8.0 Should the TSC be or become unavailable, (e.g.; due to Fire, Security Event, etc.) refer to Exhibit 11 for guidance.
(EPIP26/S10)
E7-1
A e enOYSTER CREEK EMERGENCY Number Ameren___
PREPAREDNESS EPIP-OC-.26 An Exelon/Britsh Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 8 TSC Radiological Assessment Support Engineer Checklist Initials 1.0 Report to the Radiological Assessment Coordinator (RAC) and provide support.
2.0 Establish one entry point with a frisking station as directed by the TSC Coordinator/Radiological Assessment Coordinator.
3.0 Place a sign on the south door, "This TSC Entrance Closed. Use other Door".
4.0 Perform an operational check on the continuous air monitor to ensure the system is operating. Report Status to the TSC Coordinator when complete.
5.0 Perform an operational check on the area radiation monitor to ensure the system is operating. Report Status to the TSC coordinator when complete.
6.0 Provide radiological evaluation on the air and ambient radiation levels of the TSC.
CAUTION Turn on HEPA filter when continuous air monitor trends upward after initial stabilization during startup.
6.1 If HEPA filter turned on, have filters monitored periodically (approx. every 15-30 minutes) 6.2 Post area in accordance with RadCon procedures.
6.3 Advise TSC Coordinator of survey results.
7.0 When directed by the RAC, distribute self reading dosimetry to all TSC personnel.
8.0 Perform radiological hazard/ALARA analysis for investigative, corrective, and recovery actions as directed.
9.0 On an ongoing basis determine source terms for ground and elevated releases and provide to EAC.
10.0 Perform internal and external personnel exposure evaluations as necessary.
11.0 Provide on going technical support and analysis for the radiological aspects in support of radiological control activities.
(EPIP26/Sll)
E8-1
so
- -X-OYSTER CREEK EMERGENCY N1'umDer Amer_________
PREPAPEDNES S EPIP-OC-.
26 An Exelon/BTitish Energy Company IMPLEMENTING PROCEDURE
~
Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 8 (continued)
TSC Radiological Assessment Support Engineer Checklist 12.0 Establish Radiological Communications as the other emergency centers become activated. Maintain a Communications Log.
13.0 Activate the Dose Assessment Computer and ensure operability. Perform off-site dose calculations as requested by the RAC using actual or projected source terms.
14.0 Inform the RAC, or the TSC Coordinator in the absence of the RAC, that the TSC Radiological Work Area is ready for activation.
15.0 In the event of a radiological release, recommend on-site and near site protective actions as appropriate (see Exhibit 1B for guidance).
16.0 Maintain the Emergency Classification/PAR and Meteorology Status Board.
17.0 Present all documentation generated during the performance of their duties to the TSC Coordinator.
(EPIP26/Sl1)
E8-2
OYSTER CREEK EMERGENCY Number er~eW~iUP~iRD SSEPIP-OC-
.26 Amer~en.PREPAREDNESS An Exelon/Bnibsn Energy CompanyMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 9 PRESS RELEASE APPROVAL GUIDANCE 1.0 Press releases should be issued within approximately one hour from the time that a major plant event has occurred. Press releases shall include the time that the information is current and be written in accordance with the following guidelines:
1.1 The following categories of information should be included in press releases.
- a.
Level of Emergency This is simply identifying which one of the four emergency levels was declared.
- b.
Basis for Emergency Declaration This should be a simplified description of the plant condition which produced the emergency action level (e.g., a leak of radioactive water within the plant building).
- c.
Operational Status of Plant A simple description of plant status at the time of the emergency declaration (e.g., OCNGS was operating at 100% power when the leak was discovered, however, the plant is currently reducing power).
- d.
Company/Government Interface This is intended to inform the public that OCNGS has notified and is working closely with government officials so that public confidence and company credibility can be increased.
- e.
Corrective Actions This should be a nontechnical description of what plant personnel are doing to correct the problem. It may include such language as "attempts are being made to stop the leak" or "plant personnel are investigating the cause of the leak."
- f.
Off-site Impact A statement which simply assesses what impact this event may have on the environment. This is intended to provide factual information on off-site radiological conditions (e.g., a radioactive release is in progress, however, environmental monitoring teams have not detected any radiation levels off-site in excess of normal background). The initial press release should include all or part of the above information since time is of the essence. However, at the very least, it should contain items a-e above.
2.0 In addition to the above, the following guidance should be used in issuing press releases:
- Speculation, dose projections and Protective Action Recommendations should not be included in press releases.
(EPIP26/S12)
E9-1
tote-arm-OYSTER CREEK EMERGENCY JumIer AmerGen PREPAREDNESS EPIP-OC-.26 An Exelon/British Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 9 (continued)
PRESS RELEASE APPROVAL GUIDANCE
- Press releases may have operational and radiological review but shall have concurrence by the ED. Original initialed copies are to be retained for records. Exceptions to this are limited to press releases with boiler plate information only (e.g., Pre-approved boiler plate news releases are contained in Procedure 1820-IMP-1720.01, Attachment 1) which may be issued without prior review and approval. Once the Governor has declared a "State of Emergency", all OCNGS press releases shall be provided to the State Police representative in the Media Center for review prior to final issuance. Changes made as a result of this review should be communicated to the ESD (ED if ESD is not activated).
NOTE For security related events, press releases containing potential safeguards information are to be reviewed by the Security Coordinator.
- Press releases will be reviewed expeditiously in order to support timely issuance.
- Press releases should avoid technical terms (e.g., plant names) and jargon (e.g., trip) and should be written as simple as possible. For example, ISO Condenser could be referred to as a heat removal process from the reactor.
(EPIP26/S12)
E9-2
I OYSTER CREEK EMERGENCY Number AmerGen PREPAREDNESS EPIP-OC-.26 An Exelon/British Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 10 PLAN FOR STORAGE AND TRANSFER OF CONTAMINATED WATER Prior to implementing a recovery program for handling large volumes of contaminated water, the conditions unique to the accident should be known and evaluated. Methods for dealing with large amounts of contaminated water and dependent on its volume, activity, and location, and require that technical evaluations be performed and special procedures be developed prior to implementation. Unless required by Emergency Operating Procedures or directed by the ED, it is OCNGS policy not to transfer radioactive material out of primary or secondary containment to any other storage location. For any such transfers (except as permitted by EOP's), a detailed safety evaluation must be performed and approved by the Emergency Director. This report, therefore, provides only general guidelines for the post accident handling of large volumes of contaminated water released as a result of pipe breaks that occur either in or out of primary containment.
I.
PIPE BREAK IN PRIMARY CONTAINMENT A pipe break in primary containment will cause contaminated liquid to be discharged initially to the Drywell basement floor. Depending upon the severity of the break, and if the 1-8 sump capacity is exceeded, contaminated water could eventually flood the basement and spill into the Torus. The Torus can accommodate an additional 126,000 ft3of liquid before reaching its flooded volume capacity of 213,000 ft.3.
A. Drains and Sump Operation in Primary Containment The Drywell Floor Drain Sump 1-8 is part of the Equipment and Floor Drainage System and normally collects water from spills received through the Drywell floor drains. The sump is located in the Drywell at elevation 6'0" and has an available capacity of 81.6 gallons. The sump discharge is isolated (full valve closure of containment isolation valves V-22-28, 28) on high Drywell pressure or low, low reactor water level. These valves can also be manually controlled from panel llF in Control Room by making necessary electrical changes per OCNGS Procedure 312.1, "Drywell Isolation Signal Bypass" (Emergencies). The sump pumps are interlocked to shutdown on closure of the discharge isolation valves. This allows for the isolation of contaminated liquid within primary containment. In addition, the sump can be manually isolated by closing sump pump discharge valves V-22-184, 186.
To discharge the contents of the sump for processing, pumps 1-8A and I-8B can be manually operated intermittently using their respective power supplies 1A21 and 1B21. This operation assumes that the containment isolation valves have reopened or are in the open position. Also, the sump isolation valves V-22-184, 186 should be considered for manually controlling the sump discharge flow.
(EPIP26/S13)
E10-1
lsS-OYSTER CREEK EMERGENCY NumLe-AmerGen.
PREPAREDNESS EPIP-OC-.26 An Exelon/Bribsh Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 10 (continued)
PLAN FOR STORAGE AND TRANSFER OF CONTAMINATED WATER II.
PIPE BREAK OUTSIDE PRIMARY CONTAINMENT The most likely areas for contaminated water to collect following a pipe break in the Reactor Building or Turbine Building basement are Reactor Building sump 1-6 and 1-7 and Turbine Building sump 1-3. The amount of contaminated water expected to be released during a break outside primary containment will be relieved through the floor drain system located in each building to the respective sump.
A. Drains and Sump Operation Outside Primary Containment Reactor Building Contaminated water relieved through the floor drains in the Reactor Building will collect in sumps 1-6 and 1-7 (SE Corner). The sumps are located at Elevation -19'6" and have a combined capacity of approximately 1,500 gallons. The sumps are interconnected and provided with sump inlet isolation valves (V-24-35, 36, 37, 38) which automatically close on high, high sump level. Sump 1-7 discharge lines are equipped with isolation valves (V-22-167, 169) that are manually (local) controlled to allow for sump isolation, and can be used to control sump outlet flow for intermittent liquid processing. In addition to valve manipulations, the sump pumps can be tripped off manually from the 480 switchgear room (supplies 1A21, 1B21) to allow for local sump flooding and contaminated liquid isolation.
Turbine Building The Condenser Bay Area of the Turbine Building basement is most likely to accumulate contaminated water resulting from a pipe break in the basement and steam tunnel. In the extreme case, a pipe line break (LOCA) in the Main Steam System outside primary containment would cause high pressure steam to be discharged from both sides of the break. However, the flow limiters in the main steam line would control the blowdown to 200% of rated flow. The line break would be sensed by either increased pressure drop across venturis due to high steam flow rate, or increased temperature in pipe tunnel, and main steam isolation valve closure would be activated within 0.5 seconds after break and full valve closure at 10.5 seconds. The limited amount of contaminated water deposited as the steam condense would be drained through the Equipment Floor Drain System.
The basement floor is equipped with a segregated floor drain system for controlled drainage to the Turbine Building sumps. Sump 1-3 collects the contaminated water generated in a Condenser Bay Area and would collect the water generated from a major pipe break. The sump is located at Turbine Building (NW corner of Condensate Pump Pit) at elevation 0'0" and has a capacity of 1,500 gallons.
(EPIP26/s13)
E10-2
eOYSTER CREEK EMERGENCY m
PREPAREDNESS An Exelon/&rtftsh Energy Company IMPLMENTING PROCEDURE
~-
Title THE TECHNICAL SUPPORT CENTER EXHIBIT 10 (continued)
Number EPIP-OC-.26 Revision No.
24 PLAN FOR STORAGE AND TRANSFER OF CONTAMINATED WATER The sump pump discharge valves (V-22-172, 174) are manually (local) isolated from the Turbine Building and the sump pump power supplies (lA12, 1B12) secured from Turbine Building Mezzanine North Control location. Manual isolation of sump 1-3, which is similar to the manual isolation of Reactor Building sump 1-7, will allow local flooding to occur. Intermittent pump operation or valve throttling will allow for controlled liquid processing at a desired capacity.
III. SAMPLING CONTAMINATED WATER Samples of the contaminated water should be obtained to determine the liquid's radioisotopic content and conductivity. The sampling results will influence the subsequent processing path chosen.
Possible sample points that should be investigated for use are:
TO SAMPLE Torus Drywell Sump (1-8)
USE V-21-57 LOCATION "C" Containment Spray Pump -
Reactor Building Drywell Sample Valve Reactor Building 23' Elev.
Reactor Building Sump (1-7)
Turbine Building Sump (1-6)
DS HV-133 DS HV-134 ORW Pipe Tunnel ORW Pipe Tunnel Since operation of the respective sump pumps will be required for sampling, pump run time should be minimized to limit the amount of contaminated water transported to Chem. Waste/Floor Drain System. An attempt should be made, therefore, to sample the contaminated water at a point nearest to the break location using a Geyser Pump and ALARA practices when transporting the liquid.
IV.
PROCESSING SCHEMES Prior to transferring highly contaminated water from its spill
- area, several issues need to be addressed in a technical evaluation. These include:
- 1. Does the flooded area need to be recovered radiologically to allow workers entry?
- 2. Does retaining the water pose a greater radiological concern than transferring to Radwaste?
- 3. Does Radwaste have available capacity?
- 4. Are there processing options such as a temporary demineralizer?
(EPIP26/S13)
E10-3
ts- - -I-OYSTER CREEK EMERGENCY Vunier AmerGen PREPAREDNESS EPIP-OC-.26 An Exelon/Bitsh Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 10 (continued)
PLAN FOR STORAGE AND TRANSFER OF CONTAMINATED WATER These types of concerns should be addressed on an individual basis prior to implementing a processing plan.
A. NORMAL Contaminated water generated within the plant during normal operation which collects in the Drywell, Turbine Building, or Reactor Building sumps is transferred to the Chem. Waste/Floor Drain System for processing. This system, in addition to the High Purity Liquid Waste System, comprises the new Radwaste Liquid Radwaste System. The Chem.
Waste/Floor Drain System receives the sump water in a series of collector tanks; WC-T-lA, 1B, 1C. The total combined capacity of these tanks is 42,000 gallons. In the event that this primary collector capacity is unavailable for use, 10,000 gallons of secondary collector capacity is available by diverting flow to the ORW Floor Drain Collector Tank NV-49. Flow from the Turbine Building sumps to NV-49 can be accomplished by manually opening DS-HV-111 and closing DS-HV-106 from their location in the ORW pipe tunnel. Flow from Reactor Building Sump 1-7 to NV-49 can be accomplished by closing DS-HV-109 and opening DS-HV-114. Additional tanks available for receiving water are:
Waste Neutralizer Tanks NV-05A/B -
10,000 gallons each.
High Purity Waste Collector Tank HP-T-IB -
30,000 gallons.
Water can be transferred from NV-49 to the Waste Neutralizer Tank using Section 11 of OCNGS Station Procedure 313.2.
The Chem. Waste/Floor Drain System is capable of processing water at 60 GPM with both process trains in use.
B. According to Sample Results Water with Excessively High Radioxsotopic Activity Contaminated water of excessively high radioisotopic activity which precludes safe handling and disposition will be retained at its location and processed in small enough portions such that exposures to operating personnel are not significantly impacted. The method for handling this water will depend on its location and rad levels. If necessary, steps should be taken to dilute the Contaminated water with low activity water to reduce the concentrations. Subsequent to authorization allowing the processing to occur, contaminated water located in the sumps can be directed to the Chem. Waste/Floor Drain System tanks and diluted as required. Water located in the Torus can be drained through the Containment Spray Pumps 1-3 and 1-4 manual drain valves V-21-57, 58. Manual drainage in this manner will allow water to subsequently be processed in either the High Purity System or Chem.
Waste/Floor Drain System depending on water quality. (Water sent to High Purity System should have conductivity less than 50 UMHOs/CM -
refer to SP-1302-28-001 Water Quality, OCNGS or the permission of the Manager of Chemistry).
(EPIP26/S13)
E10-4
I - -
OYSTER CREEK EMERGENCY Bumper AmerGen -
PREPAP.EDNESS ESpo-2 An ExelonfBritish Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 10 (continued)
PLAN FOR STORAGE AND TRANSFER OF CONTAMINATED WATER Outdoor Storage Limit Not Exceeded If the radioisotopic concentration of the contaminated water in the Torus is such that the outdoor storage Technical Specification (3.6.C) of 10 curies (see note below) would be exceeded, and processing cannot be initiated, outdoor storage options should be investigated. The following tanks can be used to store water:
Condensate Storage Tank -
535,000 gallons Torus Water Storage Tank -
763,000 gallons A temporary connection from the blind 14" flange off the common discharge header of containment Spray Pumps 1-3 and 1-4 will allow water to be transferred from the Torus to the above tanks.
NOTE: The new Radiological Effluents Technical Specifications Spec.
3.6.C allows storage of up to 10.0 Ci in the Condensate storage Tank. OCNGS would have to apply to the NRC for authorization to include Torus Water Storage Tank in the outdoor storage plan.
C.
Radiation Levels not a Limiting Constraint Processing through High Purity Waste System Contaminated water of low mineral content is normally processed through the High Purity System. Torus water can be routed through Containment Spray Pumps 1-3, 1-4 drain valves V-21-57, 58 and allowed to collect in the R.B.E.D.T. The contents of the tank can then be pumped directly to the High Purity Waste Collector Tanks using existing connections. Contaminated sump water can be processed through the Chem. Waste/Floor Drain System bypassing the evaporators. Processing without the evaporators will allow rates approaching 60 GPM per train.
Processing through Chem. Waste/Floor Drain System Contaminated water of high mineral content is normally processed through the Chem. Waste/Floor Drain System. Since sump water is normally processed through this system, temporary connections are not required. Contaminated Torus water can be processed through this system if the Reactor Building Equipment Drain Tank (R.B.E.D.T.) is allowed to overflow into Reactor Building sump 1-7(B). This can be accomplished by directing Torus water through Containment Spray Pumps 1-3, 4 drain valves (V-21-57, 58), so that drainage to the R.B.E.D.T. through the floor drain system will occur (see Appendix 1). The normal effluent path of R.B.E.D.T. can be manually isolated to allow for overflow by controlling pump isolation valves V-22-150, 152 from the Reactor Building or by manually controlling pump power (local controls -
supply MCC 1B21).
(EPIP26/Sl3)
O-E10-5
I OYSTER CREEK EMERGENCY NUMDer AmerGen.
PREPAREDNESS EPXP-OC-.26 An Exelon/BTitish EneTgy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 10 (continued)
PLAN FOR STORAGE AND TRANSFER OF CONTAMINATED WATER V.
STORAGE OF PROCESSED WATER The Chem. Waste/Floor Drain System has the capability of providing 20,000 gallons of primary storage space. Two Chem.
Waste Distillate Storage Tanks (WC-T-3A, 3B) normally provide space for water processed through the Chem. Waste System during normal operation. Two storage tanks, HP-T-2A, 2B, provide 60,000 gallons of High Purity Storage for water processed through the High Purity System. In addition, water processed in these two systems may be discharged to the condensate system directly if they are of condensate quality.
Secondary Storage Capacity is provided through use of the following vessels:
Condensate Storage Tank 535,000 gallons Hotwells 84,550 gallons Torus Water Storage Tank -
763,600 gallons The secondary storage capacity will find use if the Torus contents have been processed and additional storage capacity is required.
(EPIP26/S13)
E10-6
OYSTER CREEK EMERGENCY Number AmerGen-PREPAREDNESS EPIP-OC-.26 An Exelon/Britsh Energy Company IMPLEMENTING PROCEDURE K
Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 11 Relocation of the TSC 1.0 This Exhibit provides guidance for establishing TSC functions in alternate locations when directed by the ED.
2.0 TSC functions should be divided between the ECC and OSC as follows (ED may direct other arrangements as needed):
2.1 The following should relocate to the ECC, take direction from the ED, and follow EPIP-26 or EPIP-35 as appropriate.
NOTE The ECC has limited space and facilities so the number relocated here should be minimized.
2.1.1 ED ED briefings should be made on the Plant Page System or by telephone 2.1.2 ED Assistant 2.1.3 RAC/RASE 2.1.4 Core Engineer (if required in ECC) 2.1.5 Communications duties should be handled by the existing ECC communicators and the EOF for off site notifications once activated.
2.2 The following should relocate to the Drywell Command Center (Conference Room) of the OSC and take direction from the TSC Coordinator:
(EPIP26/S14)
E11-1
AmerGen.
An Exelon/BnTsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 It Title THE TECHNICAL SUPPORT CENTER Revision No.
24 I.
EXHIBIT 11 (continued)
Relocation of the TSC 2.2.1 TSC Coordinator Continue to take direction from the ED while coordinating with the OSC Coordinator to minimize interference.
2.2.2 TSC Engineers 2.2.3 TSC Communications Coordinator 2.2.4 TSC Communicators 2.2.5 TSC Tech Assistant 2.2.6 Core Engineer (if not required in the ECC)
NOTE The OSC has limited space and may be controlling several Damage Control Teams. To minimize interference only the TSC Coordinator should interface with the OSC Coordinator initially.
2.3 The following guidance is provided for integrating the TSC engineering function into the OSC.
2.3.1 TSC Engineer should establish a work space in the Drywell Command Center and survey the available procedures and drawings. If additional references are needed, they may be obtained from the Maintenance building.
2.3.2 The Plant Computer System terminal is located in the OSC in a very busy area. If it is needed, coordinate with OSC staff to minimize interference.
(EPIP26/S14)
E11-2
,1> -v OYSTER CREEK EMERGENCY eLr1.
AmerGen.
PREPAREDNESS EPIP-OC-.26 An Exelon/Brthsh Energy Company IMPLEMENTING PROCEDURE K> Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 11 (continued)
Relocation of the TSC 2.3.3 TSC Communicators may not be needed by the OSC.
However, at least one should be used to support ED/TSC Coordinator Communications. This may be via a normal telephone to ECC. This should be coordinated with the ECC Communications Coordinator.
Communicators who are not required for OSC operations may be useful at the EOF, especially if NRC is sending a response team. This should be coordinated with the EOF Communications Coordinator.
2.3.4 The Tech Assistant may be useful to assist the OSC with operational related teams. He may replace or supplement the GOS assigned to the OSC.
2.3.5 Personnel who are not required may be sent to the Emergency Assembly Area or Remote Assembly Area as appropriate. If neither Assembly Areas are activated, they may be sent home with reporting instructions for the next day (e.g.; report to site, EOF, OSC, etc.).
(EPIP26/S14)
E11-3
s -
OYSTER CREEK EMERGENCY AUrDer AmerGen.
PREPAREDNESS EPIP-OC-.26 An ExelonfBitsh EneTgy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 12 ALTERNATE EMERGENCY RESPONSE FACILITIES This exhibit provides a description of evacuation preplanning for Alternate Emergency Response Facilities as follows:
- 1. Control Room/ECC - Evacuation of Control Room -
the Operators control the plant from remote shutdown panels and the GSS directs plant operations from the TSC. All other ECC IREO members are integrated into the TSC organization. (Refer to 2000-ABN-3200.30 for specific direction).
- 2. OSC -
Evacuation of OSC -
all OSC personnel are evacuated to the SOSC which is located in the rear of the TSC. (Refer to EPIP-OC-27 for specific direction.)
- 3. TSC -
Evacuation of TSC -
the ED support staff which includes the ED, ED Assistant, RAC, and RASE evacuate to the Control Room (ECC). The Tech Support staff which includes the TSC Coordinator, TSC Engineers, Communication Coordinator, Communicators and the Tech Assistant evacuate to the OSC. The Core Engineer would initially report to the Control Room, but if his services are not needed, he will be sent to the OSC.
- 4. Remote Assembly Area -
Evacuation of RAA's -
if the Forked River Bldg. 14 RAA is not available then relocate to the Berkeley Customer Operations Center and vise versa.
- 5. Emergency Assembly Area -
The EAA may be redirected to the Forked River Assembly Area or to the Remote Assembly Area at Berkeley Line as directed by management. In this case Site Accountability is conducted as personnel exit the site.
- 6.
EOF -
There are no backup facilities for the EOF because it is remote from the site and it is unlikely that a nuclear related incident would affect both the plant and this center.
(EPIP26/S15)
E12-1
OYSTER CREEK EMERGENCY Number AmerGen-PREPAREDNESS EPIP-OC-.26 An Exelon/Bntish Energy Company IMPLEMENTING PROCEDURE le Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 13 EMERGENCY DIRECTOR AUTHORIZATION FORM FOR DEVIATIONS FROM REOUIREMENTS TYPE OF DEVIATION I.
Deviations authorized under the Emergency Plan.
Deviations from operating procedures, emergency procedures, emergency plan implementing procedures, or normal equipment operating limits that do not result in a deviation from Technical Specifications, Operating License, License Conditions or other NRC Rules, Regulations, or Orders.
II.
Deviations authorized by 10 CFR 50.54 (x) and (y) for the protection of public health and safety.
A.
Departure from a Technical Specification requirement.
B.
Departure from the Operating License.
C.
Departure from a License Condition.
(Refer to page E6-3 & 4 for assistance in defining "License Conditions")
[ ]
D.
Departure from NRC Rules, Regulations, or Orders.
'_.ations are only permissible if all of the following are met:
- 1. An Emergency condition exists which can impact the public health and Safety.
- 2.
The deviation is allowed if there are no actions which are consistent with license conditions or technical specifications.
- 3. The action must be taken immediately in order to be effective in protecting the public health and safety.
Deviation Justification:
Alternatives Considered:
SRO Concurrence_
TSC Eng. Concurrence_
ED Approval Date Time_______
NRC Notification Date Time_
NRC Person Notified (EPIP26/S16)
E13-1
Procedure EPIP-OQ-.26.
(
Rev. 24
(
EXHIBIT 13 (continued)
EMERGENCY DIRECTOR AUTHORIZATION FORM FOR DEVIATIONS FROM REQUIREMENTS t7i H
W WI LICENSED CONDITIONS REGULATION REQUIREMENT DESCRIPTION DEVIATION 10 CFR 50.54(A)
OQA Plan Plan to insure quality in all phases of A 50.54(x) deviation consists of not 10 CFR 50 APP. B Nuclear Plant operation and to enhance implementing the OQA Plan of a Safety section of the Plan to protect public safety and health. See NOTE 1 below.
Safeguards and Requirement for Physical Security and A 50.54(x) deviation is not 10 CFR 73.55 Security Plan control of information pertaining to the implementing a major portion of the method employed.
Security Plan to protect public health and safety. See Note 2 below.
Emergency Plan Plan to insure the appropriate All of these sub-parts of the 10 CFR 50.47(b) facilities, personnel, procedures and Emergency Plan are implemented via 10 CFR 50 APP. E equipment are available to adequately implementing procedures.
respond to emergencies.
Examples of 50.54(x) DEVIATIONS, The sub-parts of this item are:
while protecting public health and
- Standard Classification System safety follow:
- Notification of Local, State and Deciding intentionally to NOT-Federal Organizations
- Control exposures of all workers
- Methods, Systems & Equipment for per EPA-400 limits assessing & monitoring actual or
- Activate the Emergency Response potential radiological consequences organization
- Use of Protective Action
- Use/Activate Emergency Facilities Recommendations
- Controlling radiological exposure The other items of this part do not
- Activation/use of Emergency Response meet the criteria for a 50.54(x)
Facilities DEVIATION that would still protect
- Use of ERDS (Emergency Response Data the public health and safety. Any System) instance of not complying with these parts is a violation, but not a valid DEVIATION.
NRC Operations Requires notify and maintain A 50.54(x) deviation is when the NRC Center communications with the NRC Operations is Intentionally Not notified or Center of events specified in 10 CFR when communications with NRC is 50.72 being suspended without NRC concurrence to protect public health and safety.
Procedure EPIP-y 2N Rev. 24 K
EXHIBIT 13 (continued)
EMERGENCY DIRECTOR AUTHORIZATION FORM FOR DEVIATIONS FROM REQUIREMENTS LICENSED CONDITIONS (CONTINUED)
NOTE 1 -
The OQA Plan describes the formal plan to implement the requirements of 10 CFR 50 Appendix B. The Plan contains the controls and bases for procedures that implement the Plan. If an entire process described in the Plan is not followed, this must be considered under 10 CFR 50.54(x). It is unlikely that such a deviation could be considered to protect the health and safety of the public thus could not be authorized under 10 CFR 50.54(x).
Specific and individual deviations from the plan's implementing procedures are not considered a deviation form the Plan, and as such would still require the approval of the Emergency Director and documentation on Exhibit 6 but would not require notification of the NRC per 10 CFR 50.72(a) (2) (i)
(C).
NOTE 2 -
The Security Plan implements the requirements of 10 CFR 73.55. In essence, deviations from the Security Plan are deviations from 10 CFR 73.55 and in accordance with 10 CFR 73.55(a) are reported in accordance with 10 CFR 50.54(x). In addition to the Security Plan, 10 CFR 73.55 required a Safeguards Contingency Plan which gives guidance to accomplish specific defined objectives for different events. The Safeguards Contingency Plan is considered similar to an implementing document and therefore specific deviations from it are not 10 CFR 50.54(x) deviations. However, if whole parts of the Safeguards Contingency Plan are not followed, these should be considered under 10 CFR 50.54(x).
Example:
The Security Plan, as required by 10 CFR 73.55, contains requirements on access controls.
If access controls are suspended this should be considered a deviation of the Security Plan and be reported in accordance with 10 CFR 50.54(x). However, if access controls will be maintained but differently than described in the procedures, this is not a 10 CFR 50.54(x) deviation but would still require the appropriate approval and documentation using this exhibit page E13-1 and E13-2.
I AmerGen OYSTER CREEK
_EMERGENCY PREPAREDNESS An Exelon/Bntisn Energy Company IMPLEMENTING PROCEDURE
, Title THE TECHNICAL SUPPORT CENTER Number EPIP-OC-.26 Revision No.
24 EXHIBIT 13 (continued)
EMERGENCY DIRECTOR AUTHORIZATION FORM FOR DEVIATIONS FROM REQUIREMENTS ADDITIONAL INFORMATION AND REGULATORY EXCERPTS 50.54(x) -
A licensee may take reasonable action that departs from a license condition or technical specification (contained in a license issued under this part) in an emergency when this action is immediately needed to protect the public health and safety and no action consistent with license conditions and technical specifications that can provide adequate or equivalent protection is immediately apparent.
NOTE The NRC has interpreted 50.54(x) to apply to NRC rules, regulations and orders in addition to Technical Specifications, Licenses, and License Conditions.
50.54(y)
Licensee action permitted by paragraph (x) of this section shall be approved, as a minimum, by a licensed senior operator prior to taking the action.
73.55(a)
In accordance with section 50.54(x) and (y) of Part 50, the licensee may suspend any safeguards measure pursuant to Section 73.55 in an emergency when this action is immediately needed to protect the public health and safety and no action consistent with the license conditions and technical specifications that can be provide adequate or equivalent protection is immediately apparent. This suspension of safeguards measures must be reported in accordance with the provisions of 73.71. Reports made under Section 50.72 need not be duplicated under 73.71.
NOTE In essence, no one below a licensed SRO individual can make the decision to depart from the License. However, if a more senior manager is present (i.e., Emergency Director) even though he does not possess an SRO license, the decision authority would be passed to him as a higher authority in the chain of command. The licensed SRO shall provide his best judgment to the ED for his consideration.
Beyond that the SRO shall follow the orders of his supervisor.
It is suggested that the Emergency Director consult to the extend practicable with the Technical experts at the TSC in arriving at a decision to deviate from prescribed procedures. However, Emergency Operating Procedures should not be deviated from.
50.72(b)
Any deviation from the plant's technical specifications authorized pursuant 50.54(x) of this part.
NOTE Notify the NRC before taking action if time permits, but at least within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of the deviation.
The NRC interprets the reporting requirement to cover any departure under 50.54(x) and (y), and is not limited to Technical Specification deviations.
(EPIP26/S18)
E13-4
AmerGen l
OYSTER CREEK EMRGENCY PREPAREDNESS An Exelon/Brftish Energy Company IMPLEMENTING PROCEDURE
, Title THE TECHNICAL SUPPORT CENTER Number EPIP-OC-.26 Revision No.
24 EXHIBIT 14 CORE ENGINEERS RESPONSIBILITIES 1.0 Report to the TSC Coordinator, unless needed in the ECC.
If Core Engineer reports to ECC first, then the TSC coordinator should be informed.
2.0 As requested assist the TSC Coordinator in activation operation, and recovery of the TSC as applicable. Refer to Coordinators Checklist (Exhibit 3) for guidance.
3.0 Perform and document Core Damage Estimation Reports in accordance with EPIP-OC.33 and other engineering tasks as directed by the TSC Coordinator.
4.0 Assist with the PCS and SPDS Programs as requested.
5.0 Present all documentation generated during the performance of their duties to the TSC Coordinator.
6.0 As directed, assist TSC Coordinator in deactivation of TSC.
7.0 Should the TSC be or become unavailable (e.g., due to fire, security event, etc.) refer to EXHIBIT 11 which provides guidance for the establishment of the TSC functions in alternate locations.
(EPIP26/S19)
E14-1
I OYSTER CREEK Number A_ merGen__
_l EMERGENCY PREPAREDNESS EPIP-oc-.26 An Exelon/Bnbsh Energy Company IMPLEMENTING PROCEDURE Title Revision No.
THE TECHNICAL SUPPORT CENTER 24 EXHIBIT 15 SITE ACCESS POLICY FOR MEDIA DURING EMERGENCIES Providing reasonable site access to the media during a plant emergency is in the best interest of OCNGS and the public.
Responsibility for approving site access rests with the Emergency Support Director, or, if the EOF is not activated, with the Emergency Director.
For purposes of media access to the site during an emergency, the same industrial safety and security standards and requirements that apply to non-essential employees will be applied to the media.
Communication Dept. Responsibilities Request for media access will be made to the ESD or ED by the Public Information Duty Representative or the Media Center Lead.
Communications will provide the ED/ESD with the number of media to gain site access, areas to be accessed and length of time the media will be there.
(Communications will decide the number of media gaining access based on conditions at the time of the emergency. An attempt will be made to gain access for, at a K__> minimum, one representative each from radio, television and print media.)
Communications will provide media transportation on and off site.
Communications will have each member of the media sign a Media Access Briefing Form, Exhibit 20, indicating they were briefed about the risks as they were known at the time by the corporation.
- 1. If media access does not involve entry into a posted radiologically controlled area:
- a. At Oyster Creek, Security will retain responsibility for sign in and badging.
- b. Communications will supervise and escort the media while on site.
- c. Communications will conduct a briefing explaining the radiological and industrial conditions and risks on site.
- 2. If media access involves entry into a posted radiologically controlled area:
- a. Media will be processed as appropriate, receiving dosimetry, training, bioassay, waivers and briefings based on established procedural requirements.
- b. Communications will notify the Security Coordinator prior to site access.
(EPIP26/S20)
E15-1
AmerGen An Exelon/Sntish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 I
t Title THE TECHNICAL SUPPORT CENTER Revision No.
24 EXHIBIT 15 SITE ACCESS POLICY FOR MEDIA DURING EMERGENCIES (continued)
- c.
Communications in conjunction with Radiological Controls will supervise and escort the media while in posted radiologically controlled areas.
ED/ESD Responsibilities
- 1.
The ED/ESD will consult with the RAC/Group Leader R&EC, and media may be granted access if the projected dose will not exceed the 500 millirem annual limit including external and internal exposure.
NOTE For security driven events, Media access to the site must also be approved by the local Law Enforcement Agency and Security.
- 2. Approve media access to the site if requirements are met.
(EPIP26/S20)
E15-2
AmerGmen An Exelon/British EneTgy Conmpany OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 I
R N
I Title THE TECHNICAL SUPPORT CENTER Revision No.
24 EXHIBIT 16 Page of EMERGENCY SHIFT SCHEDULE EXAMPLE DATE:
GROUP (eg. Admin.):
TIME:
SHIFT 1 SHIFT 2 SHIFT 3 BEGIN END NAME NAME NAME POSITION #
P HOME#
H O
WORK#
N E
BEEPER #
POSITION #
P HOME #
H O
WORK #
N E
BEEPER #
POSITION #
P HOME #
H O
WORK#
N E
BEEPER #
POSITION #
P HOME #
H
° WORK #
N E
BEEPER#
(EPIP26/S21)
E16-1
AmerGen.
An Exelon/Bntish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 I.
1 Title
\\_-_
THE TECHNICAL SUPPORT CENTER Revision No.
24 EXHIBIT 17 HIFAX LOG EXAMPLE SEND MESSAGE TIME INITIAL TSC OSC EOF ECC COMMENTS I i It t
I I
I
+
t
_ I I
i
+
t t
I_
I1 1
i 1
t I
I.
I i
I I 4 I.
i 4
I I
i+
i i
I I
4 4
i 1
1 I
_ I I
i fi i
i II__
I i
1-I_
J.
I i
+
t i
I1 i
ti I
I 4
i I
I I.
IiI I
.i.
I i i
i TSC OSC EOF ECC COMMENTS (EPIP26/S22)
E17-1
Ameruen OYSTER CREEK NUmb EMERGENCY PREPAREDNESS EP An Exelon/Bntsh Energy Company IMPLEMENTING PROCEDURE Title Revi THE TECHNICAL SUPPORT CENTER EXHIBIT 18 EXAMPLE OYSTER CREEK NUCLEAR GENERATING STATION EMERGENCY COMMUNICATIONS Communicator Log Location:
Date:
ier
'IP-OC-.26
.sion No.
24 ERF Circuit:
Name:
Time:
Remarks:
(EPIP26/S23)
E18-1
AmerGmen.
An Exelon/Brftish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 ReisonNo Title
~
THE Revision No.
EXHIBIT 19 EXAMPLE Number OCNGS Emergency Message To:
OSC TSC EACC ECC EOF Staff Position Other Message:
Originator:
Staff Position Initials Time Date Location:
Reply Completed by:
Staff Position/Other Initials Time Date A0001731 10-84 (EPIP26/S24)
E19 -1
Am Ge OYSTER CREEK
__EMERGENCY PREPAREDNESS An Exelon/Bnrtsh Energy Company IMPLEMENTING PROCEDURE Title THE TECHNICAL SUPPORT CENTER EXHIBIT 20 MEDIA ACCESS BRIEFING FORM Number EPIP-OC-.26 Revision No.
24 I have been briefed about the risks, both industrial and radiological, to which I may be exposed while at this nuclear facility.
I understand there may be some risk and willingly accept it for the purpose of visiting the plant site.
Signature_
Date News Organization_
Communications Rep.
(EPIP02/S25)
E20-1
AmerGenm An Exelon/Brttish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.26 Title
\\__'
THE TECHNICAL SUPPORT CENTER Revision No.
24 EXHIBIT 21 PAR NOTIFICATION FORM NOTE Personally provide the PAR to the Senior State Official at the State EOC, within 15 minutes of a General Emergency. Verify that you are speaking to the Senior Official at the State EOC when providing the PAR.
If the PAR is provided prior to State EOC activation, the State has agreed that the State Dispatcher will be considered the "Senior State Official".
INITIAL PAR El This is a Drill.
This is a Drill.
Dl This is an Actual Emergency.
This is an Actual Emergency.
al We recommend evacuation for the general population within 2 miles of the plant and Compass Sectors and out to a distance of _
miles.
We also recommend Sheltering, for the general population within all other areas of the EPZ.
El We recommend Sheltering for the general population within the 10 mile EPZ.
El Recommend use of KI El Yes M
No EXPANSION OF PAR E]
We recommend evacuation for the general population within _
miles of the plant and Compass Sectors and out to a distance of I miles.
We also recommend sheltering for the general population within all other areas of the EPZ.
a We recommend evacuation for the general of the plant.
population within _
miles El Recommend use of KI Dl Yes El No Signature Time Date__
Senior State Official Notified Time_
_ Date_
(EPIP02/S26)
E21-1
Number OYSTER CREEK AmerGen_
_l EMERGENCY PREPAREDNESS EPIP-OC-.44 An Exelon/British Energy Company IMPLEMENTING PROCEDURE Title Usage Level Revision No.
THYROID BLOCKING 2
Prior Revision 2
incorporated the This Revision 3
incorporates the following Temporary Changes:
following Temporary Changes:
N/A N/A List of Pages 1.0 to 3.0 El-i E2-1 E3-1 E4-1 NON-CONTROLLED This Document Will Not Be Kept Up To Date DCC Oyster Creek (EPIP44)
- 1. 0
AmerGen An Exelon/Brltlsh Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.44 V
i J
J'JLIA
-M Title 3
THYROID BLOCKING REV.
DATE ORIGINATOR 0
02/99 A. Smith Change EPR EPIP-OC-.a I
Inlc-n qrlrl
SUMMARY
OF CHANGE IP-COM-.44 Thyroid Blocking to 14 making it Oyster Creek specific.
Procedure History page.
The change affect the contents of the
, only the numbering.
does not,
procedure
_ ~I 11 1
2 3
DOS 06/01 3/20 A. Smith A. Smith M. Chanda Change references from GPU or GPUN to OCNGS.
Update titles; Safety Review from Yes to No.
Change Medical Representative to Radiological Controls Coordinator I
I _
(EPIP44)
- 2. 0
Am erGen.
OYSTER CREEK kl EMERGENCY PREPAREDNESS An ~ ~
~
~
~
~
~
~
~ ~ ~
Exlnfns nyur^lyI P.iM3TNUJU~;L,.M U
Number EPIP-OC-.44 Ani Exel-6-10,oIIi E-j9 I
AJL1LV=
1,4X.
I Title Revision No.
THYROID BLOCKING 3
1.0 PURPOSE 1.1 The purpose of this procedure is to provide guidance to site personnel for the administration of potassium iodide tablets as a thyroid blocking agent in the event of actual inhalation or ingestion by site personnel of large quantities of radioiodine.
2.0 APPLICABILITY/SCOPE 2.1 This procedure applies to all personnel involved in emergency or recovery related activities at Oyster Creek.
3.0 DEFINITIONS 3.1 Radioiodine -
Any of the radioactive isotopes of iodine.
4.0 RESPONSIBILITIES 4.1 Radiological Assessment Coordinator (RAC) is responsible for completing Exhibit 1.
4.2 Radiological Controls Coordinator is responsible for completing Exhibits 2 and 3.
5.0 PROCEDURE 5.1 Implementation Criteria 5.1.1 This procedure is to be initiated upon verification'by the RAC that person(s) have been exposed to quantities of radioiodine resulting in a thyroid committed dose equivalent (CDE) of greater than or equal to (25 REM).
6.0 REFERENCES
6.1 2000-PLN-1300.01 OCGS Emergency Plan 7.0 EXHIBITS Exhibit 1 -
Radiological Assessment Coordinator Checklist Exhibit 2 -
Radiological Controls Coordinator Checklist Exhibit 3 -
Thyroid Blocking Agent Administration Form Exhibit 4 -
Thyroid Blocking Agent Precautions (EPIP44) 3.0
AmerGen-An Exelon/Bntish Energy Company OYSTER CREEK EMERGENCY PREPAREDNESS IMPLEMENTING PROCEDURE Number EPIP-OC-.44 Iv~
a M
r)~usi o
Title THYROID BLOCKING 3
EXHIBIT 1 Radiological Assessment Coordinator Checklist Initials 1.0 Determine if one or more individuals have received an uptake of radioiodine resulting in a thyroid committed dose equivalent (CDE) of greater than or equal to (25 REM).
Consult with the Radiological Controls Coordinator on the benefits of administering stable iodine (KI).
NOTE The Thyroid Dose to an individual may be determined as follows:
A. Using an air sample, the thyroid dose is calculated as 25 mrem per DAC-hr.
B. Having the individual get a whole body count if the whole body counter is available.
The whole body counter software will calculate the thyroid dose.
NOTE Potassium iodide is not to be used in lieu of proper respiratory protection (i.e., as a prophylactic).
Potassium iodide is only to be used to block the thyroid gland shortly after accidental or unavoidable inhalation or ingestion of radioiodine.
II 2.0 If the decision is to administer stable iodine, (KI) arrange for an escort to transport the exposed individual(s) to the Radiological Controls Coordinator's location, if needed.
3.0 Arrange for a bioassay to be performed on each exposed individual of concern after issuance or refusal of the thyroid blocking agent.
(EPIP44/S3)
El-l
Number Amer~.enuqi OYSTER CREEK C_______EMERGENCY PREPAREDNESS EPIP-OC-.44 An Exelon/Bntish Energy Company IMPLEMENTING PROCEDURE Ttle Revision No.
THYROID BLOCKING 3
EXHIBIT 2 Radiological Controls Coordinator Checklist Initials 1.0 Upon the decision to administer stable iodine (KI), notify the Radiological Controls Coordinator.
Consult with Occupational Health or other medical authority, as appropriate, concerning the efficiency of potassium iodide usage in regards to duration of exposure, magnitude of exposure, and time since exposure for each individual.
2.0 Upon assembling the exposed individual(s), direct the exposed individual(s) to read the thyroid blocking agent precaution leaflet (Exhibit 4) and sign the Thyroid Blocking Agent Administration Form (Exhibit 3).
This signature verifies that the individual has read and understands the leaflet, understands that taking thyroid blocking agent is voluntary, and has no known allergy to Iodine.
All exposed individuals will be offered thyroid blocking agent whether or not they refuse to sign Exhibit 3.
3.0 Issue one sealed container of thyroid blocking agent (14 tablets potassium iodide) to each individual and instruct them to follow the label instructions.
Label instructions may be altered only by a qualified Physician.
NOTE Thyroid blocking agent is stored in the Occupational Health Services Dept.
4.0 Verify by signature on Exhibit 3 that thyroid blocking agent was issued to the exposed individual or if refused, note the refusal on Exhibit 3 (if possible, record refusal reason on reverse side of form).
5.0 Keep all completed Administration Forms (Exhibit 3) in the persons medical file.
(EPIP44/S4)
E2-1
Number A erGen.
OYSTER CREEK.44 m er V endM~GENCY PREPAREDNESS P-O.4 An Exelon/Brftish EneTgyCompany IMPLEMENTING PROCEDURE Title Revision No.
THYROID BLOCKING 3
EXHIBIT 3 THYROID BLOCKING AGENT ADMINISTRATION FORM Name of Exposed Individual Last First Middle Social Security Number Badge Number TLD Number Duration of Exposure Hours Iodine DAC Fraction Estimated DAC-hrs DAC-hrs Estimated Thyroid Dose mrem (i.e., DAC-hr x 25)
Date of Exposure Time Exposure Ended RWP Number (if applicable)
Respiratory Protection worn during Exposure NOTE Obtain exposure information from the Rad Con Coordinator.
NOTE Although 10 CFR 20 allows up to 50 Rem per year, EPA and FDA guidance recommend considering the use of XI for acute exposures of 25 Rem or greater (CDE) to the adult thyroid in order to maintain exposures As Low As Reasonably Achievable.
I verify that I have read and understand the precaution leaflet and understand that taking thyroid blocking agent is voluntary.
I also verify that I have no known allergy to Iodine.
I accept/refuse (circle one) thyroid blocking agent.
- Signature of Exposed Individual Date Potassium Iodide tablet issued by:
/
/
- Signature of Radiological Controls Date Time Coordinator Whole Body Count Schedule at:
/
Time Date Whole Body Count Completed at:
/
/-
Time Date Signature of WB Count Tech
- If the exposed individual refuses to sign but desires to take the thyroid blocking agent, issue the thyroid blocking agent and note the refusal to sign in the signature block.
IrlRnI*4
/S E3-1
% F':1F4 J
Number BOYSTER CREEK EMERGENCY PREPAREDNESS EPIP-OC-.44 An Exelon/Brtish Energy Company IMPLEME1NTING PROCEDURE Title Revision No.
THYROID BLOCKING 3
EXHIBIT 4 THYROID BLOCKING AGENT PRECAUTIONS HOW POTASSIUM IODIDE WORKS Certain forms of iodine help your thyroid gland work right. Most people get the iodine they need from foods, like iodized salt or fish.
The thyroid can "store" or hold only a certain amount of iodine.
In a radiation emergency, radioactive iodine may be released in the air.
This material may be breathed or swallowed.
It may enter the thyroid gland and damage it.
The damage would probably not show itself for years.
Children are most likely to have thyroid damage.
If you take potassium iodide, it will fill-up your thyroid gland with non-radioactive iodine.
This reduces the chance that radioactive iodine will enter the thyroid gland.
WHO SHOULD NOT TAKE POTASSIUM IODIDE The only people who should not take potassium iodide are people who know they are allergic to iodide.
You may take potassium iodide even if you are taking medicines for a thyroid problem (for example, a thyroid hormone or anti-thyroid drug).
Pregnant and nursing women and babies and children may also take this drug.
HOW AND WHEN TO TAKE POTASSIUM IODIDE Potassium Iodide should be taken as soon as possible after medical personnel tell you.
You should take one dose every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
More will not help you because the thyroid can "hold" only limited amounts of iodine.
Larger doses will increase the risk of side effects.
You will probably be told not to take the drug for more than 10 days.
SIDE EFFECTS Usually, side effects of potassium iodide happen when people take high doses for a long time.
You should be careful not to take more than the recommended dose or take it for longer than you are told.
Side effects are unlikely because of the low drug dose and the short time you will be taking the drug.
Possible side effects include skin rashes, swelling of the salivary glands, and "iodism" (metallic taste, burning mouth and throat, sore teeth and gums, symptoms of a head cold, and sometimes stomach upset and diarrhea).
A few people could have an allergic reaction with more serious symptoms.
These could be fever and joint pains, or swelling of parts of the face and body at times severe shortness of breath (EPIP44/S6)
E4-1